Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.5 LAccepted-AOC S 170 B 192 VILLAGE JHARERA DELHI SOUTH WEST DELHI DELHI 110010 | NEW DELHI | DELHI | 110010 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹21.0 L+₹42,252 (2.06%)Rejected-Finance GROUND FLOOR F 11 PHASE II MAYAPURI WEST DELHI DELHI 110064 | DELHI | WEST DELHI | DELHI | 110064 | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹21.5 L+₹92,110 (4.48%)Rejected-Finance RZ A2 2 CHANAKYA PLACE PART I OPP C 1A BLOCK JANAK PURI NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹22.3 L+₹1.8 L (8.63%)Rejected-Finance 441 G F LIG FLATS PH 2 SEC 14 PKT 3 DWARKA NEW DELHI SECTOR 14 DWARKA DWARKA SOUTH WEST DELHI DELHI 110078 | SOUTH WEST DELHI | DELHI | 110078 | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹25.2 L+₹4.6 L (22.5%)Rejected-Finance 97 19 JWALA HERI PASCHIM VIHAR NEW DELHI 110063 | WEST | DELHI | 110063 | L5 | Rejected-Finance Not Being L1 |
| Sl No | Description | Qty | Unit | RUCHIKA ENGG.WORKS L3 | Ayush Enterprises L1 | RefAir Technical Services L5 | OMVIN ENTERPRISES LLP L4 | AMIT ENTERPRISES L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, installation, testing and commissioning of air purification system for Spilt AC's with Advanced Oxidation Plasma cells comprising of UVC lamp 254nm having nanoX metallic compound target Alumninum matrix cell duly enclosed by a poly casing tube, with the capability to produce Hydroxyl oxidizers. The unit shall have inbuilt multipin plasmOX generator having 6 pins with minimum anion denisty 10*10*6 per cm². The UV-C lamp will be a low-pressure mercury type and of such intensity as to provide minimum performance as listed below. The UV-C lamp will produce only germicidal UV (no board spectrum lamp). The system shall be capable of reducing microbial bacteria, virus and spores , VoC’, odors and particulates matter. The equipment shall have to GreenPro,TUV,CE, UL 60335-1+UL 60335-2-40, ISO 13485, RoHS with 2014/35/EU Low voltage directive along with FDA compliance certifications. The system shall have a microbiological testing report against Bacteriophage (MS-2 FDA) surrogate SARS Cov-2 with a minimum efficiency of 99 percent along with a Virology report from CCMB lab with an minimum efficiency of 99 percent against SARS COV2 within 45 minutes. The technology shall be tested by ICMR/ IIT on human Alveolar Basal Epithelial Cells stating that there is no change in the structure and prove that it is absoluely safe for humans. The air purfication unit does not produces ozone, the test certificate shall be produced. The units shall be 100 percent manufcaturered in India. Vendor to comply all Tender Specifications.
Note :cost of Installation included in quoted rate
Make:Ultrapure,Eflow,Aqua Air,Riania Air solution | 21 | Each | 42,800 ₹8,98,800 | 40,500 ₹8,50,500 Lowest | 45,500 ₹9,55,500 | 44,000 ₹9,24,000 | 42,600 ₹8,94,600 |
| 2.00 | Suply and fix 1.5 sqmm 3 core copper cable complete all as specified and directed | 40 | RM | 60 ₹2,400 | 40 ₹1,600 Lowest | 120 ₹4,800 | 50 ₹2,000 | 51 ₹2,040 |
| 3.00 | Suply and fix modular switch socket 6 A with frame and plate complete all as specified and directed | 21 | Each | 200 ₹4,200 | 240 ₹5,040 | 180 ₹3,780 Lowest | 180 ₹3,780 Lowest | 222 ₹4,662 |
| 4.00 | Supply, installation, testing and commissioning of wall mounted Hygiene & Odor Control unit which is advance oxidation with nanoX & plasmOX based system. Advance oxidation plasma using unique wave-length photon special metal catalyst layer with the capability to generate Hydroxyl to eliminate contamination in the conditioned space. The system shall have an independent centrifugal fan and on/ off switch. The equipment shall be enclosed in PU coated material for durability and better aesthetics. The units should be designed after undertaking a load factor calculation for each specific area where the equipment is to be installed. The load shall clearly state the number of units required. The system shall be capable of eleminating bad odors, VoC's as well as bacteria, virus, spores and particulates matter. Contaminated Air will be Sucked from one Side and Decontaminated Air will come out from other side. The equipment shall have to GreenPro,CE,ISO 13485,TUV,ROHS with 2014/35/EU Low voltage directive along with FDA compliance certifications. The system shall have a microbiological testing report against Bacteriophage (MS-2 FDA) surrogate SARS Cov-2 with a minimum efficiency of 99 percent along with a Virology report from CCMB lab with a minimum efficiency of 99 percent against SARS Cov-2 within 45 minutes. The unit should have AOP cells with inbuilt fan to be to take care off in respect of air borne contamination (VOC, Odors as well as bacteria, virus, spores) and ionizers to take care of particulates,Single Skin SS unit with PU coated,The units shall be placed over the wall as having pores for air suction & .... Contd/... | 25 | Each | 32,900 ₹8,22,500 | 32,000 ₹8,00,000 Lowest | 41,000 ₹10,25,000 | 34,000 ₹8,50,000 | 32,000 ₹8,00,000 Lowest |
| 4.10....discharge,Air Flow Direction:Towards Lamp,Power Consumption:35 Watts.Performance: The AOP cell technology features a UV lamp and rare metallic target that combine to generate nature’s friendly oxidizers like ionized hydroxyls, hydrogen peroxide to take care of Odor, VOC and ionizers to take care of particulates .Certification -The equipment shall conform to TUV, CE, ISO, GreenPro, ROHS & FDA. To be submitted along with submittal Note:-Make Ultrapure,Eflow,Aqua Air,Riania Air solution | ||||||||
| 5.00 | M & L for point wiring of on surface with casing caping, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable connected to common earth and earth dolly with suitable copper lugs drawing into and including rigid PVC surface casing and caping complete with all accessories, flush box suitable for modular / conventional switches / sockets / fan regulators with cover plates, blanking plates, brass screws, cup washers etc all as specified and directed for the followings :-
Note:Casing Capping required deemed to be included in quoted rate | 25 | Each | 290 ₹7,250 | 250 ₹6,250 Lowest | 250 ₹6,250 Lowest | 250 ₹6,250 Lowest | 300 ₹7,500 |
| 6.00 | S & F switch piano flush type single pole 1 way 5/6A,complete all as specified and directed | 25 | Each | 25 ₹625 | 30 ₹750 | 20 ₹500 Lowest | 20 ₹500 Lowest | 20 ₹500 Lowest |
| 7.00 | S&F socket 2 in 1 , 3 Pin 5 Amp flush type complete all as specified and directed | 25 | Each | 45 ₹1,125 | 50 ₹1,250 | 35 ₹875 Lowest | 50 ₹1,250 | 40 ₹1,000 |
| 8.00 | Taking down carefully unsv Geysers of any size / type from the location withing AHRR complex and depositing to MES store complete all as directed. | 60 | Each Job | 50 ₹3,000 | 50 ₹3,000 | 100 ₹6,000 | 40 ₹2,400 Lowest | 40 ₹2,400 Lowest |
| 9.00 | Supply and fix electric water heater, 25 Ltr Capacity, Horizontal Type, suitable for low ceiling fixing, storage type steel / ABS body with suitable type of inner tank and heating element upto 2 KW, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection pipes (SS) brided type etc complete with fixing arrangement including grouting of nuts, bolts, fastners of suitable size, electric connection etc all as specified and directed.
Make : Racold / Havells / AO Smith / Dyson / Siemens / BOSCH. Note : Contractor will submit guarantee/warranty certificate from manufacturer | 40 | Each | 7,490 ₹2,99,600 | 7,200 ₹2,88,000 Lowest | 9,400 ₹3,76,000 | 8,000 ₹3,20,000 | 7,200 ₹2,88,000 Lowest |
Tender Value
₹25.4 L
EMD Value
₹50,700
Closing Date
11 Feb 2026, 6:00 pmClosed
GE E/M RR HOSP DELHI CANTT-10
GE E/M RR HOSP DELHI CANTT-10
PROVN OF UV ENABLED AIR PURIFIER SYSTEM IN SPLIT ACS, PROVN OF HYGIENE AND ODOUR CONTROL EXHAUST FAN FOR WASHROOMS AND REPAIR/ REPLACEMENT OF GEYSERS AGAINST BER AT AHRR UNDER GE E/M RR HOSP DELHI CANTT-10
2025_MES_741498_2
GE/H/T-75/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE E/M RR HOSP DELHI CANTT-10
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE E/M RR HOSP
₹50,700
Yes
5 Mar 2026
28 Jan 2026
13 Feb 2026
28 Jan 2026
11 Feb 2026
4 Feb 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, installation, testing and commissioning of air purification system for Spilt AC's with Advanced Oxidation Plasma cells comprising of UVC lamp 254nm having nanoX metallic compound target Alumninum matrix cell duly enclosed by a poly casing tube, with the capability to produce Hydroxyl oxidizers. The unit shall have inbuilt multipin plasmOX generator having 6 pins with minimum anion denisty 10*10*6 per cm². The UV-C lamp will be a low-pressure mercury type and of such intensity as to provide minimum performance as listed below. The UV-C lamp will produce only germicidal UV (no board spectrum lamp). The system shall be capable of reducing microbial bacteria, virus and spores , VoC’, odors and particulates matter. The equipment shall have to GreenPro,TUV,CE, UL 60335-1+UL 60335-2-40, ISO 13485, RoHS with 2014/35/EU Low voltage directive along with FDA compliance certifications. The system shall have a microbiological testing report against Bacteriophage (MS-2 FDA) surrogate SARS Cov-2 with a minimum efficiency of 99 percent along with a Virology report from CCMB lab with an minimum efficiency of 99 percent against SARS COV2 within 45 minutes. The technology shall be tested by ICMR/ IIT on human Alveolar Basal Epithelial Cells stating that there is no change in the structure and prove that it is absoluely safe for humans. The air purfication unit does not produces ozone, the test certificate shall be produced. The units shall be 100 percent manufcaturered in India. Vendor to comply all Tender Specifications.
Note :cost of Installation included in quoted rate
Make:Ultrapure,Eflow,Aqua Air,Riania Air solution | 21 | Each | - | - |
| 2 | Suply and fix 1.5 sqmm 3 core copper cable complete all as specified and directed | 40 | RM | - | - |
| 3 | Suply and fix modular switch socket 6 A with frame and plate complete all as specified and directed | 21 | Each | - | - |
| 4 | Supply, installation, testing and commissioning of wall mounted Hygiene & Odor Control unit which is advance oxidation with nanoX & plasmOX based system. Advance oxidation plasma using unique wave-length photon special metal catalyst layer with the capability to generate Hydroxyl to eliminate contamination in the conditioned space. The system shall have an independent centrifugal fan and on/ off switch. The equipment shall be enclosed in PU coated material for durability and better aesthetics. The units should be designed after undertaking a load factor calculation for each specific area where the equipment is to be installed. The load shall clearly state the number of units required. The system shall be capable of eleminating bad odors, VoC's as well as bacteria, virus, spores and particulates matter. Contaminated Air will be Sucked from one Side and Decontaminated Air will come out from other side. The equipment shall have to GreenPro,CE,ISO 13485,TUV,ROHS with 2014/35/EU Low voltage directive along with FDA compliance certifications. The system shall have a microbiological testing report against Bacteriophage (MS-2 FDA) surrogate SARS Cov-2 with a minimum efficiency of 99 percent along with a Virology report from CCMB lab with a minimum efficiency of 99 percent against SARS Cov-2 within 45 minutes. The unit should have AOP cells with inbuilt fan to be to take care off in respect of air borne contamination (VOC, Odors as well as bacteria, virus, spores) and ionizers to take care of particulates,Single Skin SS unit with PU coated,The units shall be placed over the wall as having pores for air suction & .... Contd/... | 25 | Each | - | - |
| 4.1 | ....discharge,Air Flow Direction:Towards Lamp,Power Consumption:35 Watts.Performance: The AOP cell technology features a UV lamp and rare metallic target that combine to generate nature’s friendly oxidizers like ionized hydroxyls, hydrogen peroxide to take care of Odor, VOC and ionizers to take care of particulates .Certification -The equipment shall conform to TUV, CE, ISO, GreenPro, ROHS & FDA. To be submitted along with submittal
Note:-Make Ultrapure,Eflow,Aqua Air,Riania Air solution | - | - | - | - |
| 5 | M & L for point wiring of on surface with casing caping, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable connected to common earth and earth dolly with suitable copper lugs drawing into and including rigid PVC surface casing and caping complete with all accessories, flush box suitable for modular / conventional switches / sockets / fan regulators with cover plates, blanking plates, brass screws, cup washers etc all as specified and directed for the followings :-
Note:Casing Capping required deemed to be included in quoted rate | 25 | Each | - | - |
| 6 | S & F switch piano flush type single pole 1 way 5/6A,complete all as specified and directed | 25 | Each | - | - |
| 7 | S&F socket 2 in 1 , 3 Pin 5 Amp flush type complete all as specified and directed | 25 | Each | - | - |
| 8 | Taking down carefully unsv Geysers of any size / type from the location withing AHRR complex and depositing to MES store complete all as directed. | 60 | Each Job | - | - |
| 9 | Supply and fix electric water heater, 25 Ltr Capacity, Horizontal Type, suitable for low ceiling fixing, storage type steel / ABS body with suitable type of inner tank and heating element upto 2 KW, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection pipes (SS) brided type etc complete with fixing arrangement including grouting of nuts, bolts, fastners of suitable size, electric connection etc all as specified and directed.
Make : Racold / Havells / AO Smith / Dyson / Siemens / BOSCH. Note : Contractor will submit guarantee/warranty certificate from manufacturer | 40 | Each | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.76 MB
TENDERT75R.pdf
Tender Documents • 1.28 MB
BOQ_840274.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .