Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.8 LAdmitted-Finance VPO DUMERKHA KALAN TEH NARWANA 126116 | DUMERKHA KALAN | JIND | HARYANA | 126116 | ₹4.8 L | L1 | Admitted-Finance |
| 2 | L2₹4.8 LAdmitted-Finance PLOT 411 GALI NO 9 GANDHI NAGAR GANDHI NAGAR 122001 | GANDHI NAGAR | GURUGRAM | HARYANA | 122001 | ₹4.8 L | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | The V.K. Co-Operative Labour & Construction Society Limited L1 | THE JIYA CO-OPERATIVE LABOUR & CONSTRUCTION SOCIETY LIMITED L2 |
|---|---|---|---|---|---|
| 1.00 | Supply and erection of PVC copper insulated and sheathed 3-core circular flexible wire make Havells, KEI, Kalinga, Polycab etc. Rate are taken from work order no. HEWP/AC-33359 dated 14.09,2023. including GST Size 1.50sqmm(80/0.20mm) | 600 | Metre | 35 ₹21,000 Lowest | 36 ₹21,600 |
| 2.00 | Providing and fixing of head frame on pole with mounting arrangement of 4 LED flood Light. Rate is taken From Work order no. HEWP/AC-56353 Dated-16/12/2023 and including GST | 6 | Each | 1,800 ₹10,800 Lowest | 1,820 ₹10,920 |
| 3.00 | Supplying, installation, Testing and Commissioning of Street light LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency )85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency )85%,THD ( 10% as per IEC 61000-3-2 , P. F.=0.95, IP- 66,IK-10, CRI )80, under voltage and over voltage protection, EMI- EMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement.,
suitable to fit in up to 65mm dia pipe, life time (LED,Driver and electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin),SDCM(Standard Deviation Color Matching) (5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =105 (120 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).
150 watt | 24 | Each | 4,250 ₹1,02,000 Lowest | 4,255 ₹1,02,120 |
Tender Value
₹4.8 L
EMD Value
₹9,540
Closing Date
26 Aug 2026, 5:00 pmClosed
Ashwani Gour
Municipal Corporation Faridabad
Providing and fixing of 06 nos. of mini high mast light 8 mtr long at Palika bazar, Sihi gate road Ward No. 43, Ballabgarh. Including 5 years defect liability period, ON/OFF of street lights and watch and ward free of cost.
2026_HRY_542385_1
2026B61CCBB0 3378 4ED6 8BAB A25C0E25B361284ULB
Open Tender
Electrical Works
Works
150 days
Faridabad (MC)
Providing and fixing of 06 nos. of mini high mast light 8 mtr long at Palika bazar, Sihi gate road Ward No. 43, Ballabgarh. Including 5 years defect liability period, ON/OFF of street lights and watch and ward free of cost.
2 documents required · 2 mandatory
₹500
₹9,540
Yes
27 Aug 2026
20 Aug 2026
27 Aug 2026
20 Aug 2026
26 Aug 2026
20 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply and erection of PVC copper insulated and sheathed 3-core circular flexible wire make Havells, KEI, Kalinga, Polycab etc. Rate are taken from work order no. HEWP/AC-33359 dated 14.09,2023. including GST Size 1.50sqmm(80/0.20mm) | - | Metre | - | - |
| 2 | Providing and fixing of head frame on pole with mounting arrangement of 4 LED flood Light. Rate is taken From Work order no. HEWP/AC-56353 Dated-16/12/2023 and including GST | - | Each | - | - |
| 3 | Supplying, installation, Testing and Commissioning of Street light LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency )85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency )85%,THD ( 10% as per IEC 61000-3-2 , P. F.=0.95, IP- 66,IK-10, CRI )80, under voltage and over voltage protection, EMI- EMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement.,
suitable to fit in up to 65mm dia pipe, life time (LED,Driver and electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin),SDCM(Standard Deviation Color Matching) (5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =105 (120 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).
150 watt | - | Each | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.98 MB
BOQ_621854.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].