| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.7 CrAccepted-AOC | ₹6.7 Cr | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹7.2 Cr+₹47.8 L (7.11%)Rejected-Finance ASSAM RIFLES BAZAR NON CSD CANTEEN HAPPY VALLEY SHILLONG SHILLONG MEGHALAYA 793007 UDYAM ML 04 0000191 17AAJHS0378E3ZZ B R | EAST KHASI HILLS | MEGHALAYA | 793007 | ₹7.2 Cr+₹47.8 L (7.11%) | L2 | Rejected-Finance Not L1 |
| 3 | Rejected-Technical | - | - | Rejected-Technical Rejected due to two class below of eligible class |
| 4 | Rejected-Technical | - | - | Rejected-Technical Rejected due to two class below of eligible class |
Tender Value
₹7.7 Cr
EMD Value
₹7.1 L
Closing Date
2 Aug 2022, 6:00 pmClosed
CHIEF ENGINEER
HEADQUARTER CHIEF ENGINEER JAIPUR ZONE JAIPUR
ADDN/ALTN INCL REPAIRS TO OFFRS MD ACCN AT PRATAP LINE AT JAIPUR MIL STN
2022_MES_523350_2
CEJZ/NIT/JPR-01 OF 2022-23
Open Tender
Civil Works
Item Rate
390 days
Jaipur
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,000
Yes
GE (South) Jaipur
₹7.1 L
Yes
12 Sept 2022
14 Jul 2022
4 Aug 2022
14 Jul 2022
2 Aug 2022
21 Jul 2022
Amount
Taking down cement plaster any description, on brick or stone walls, etc. including raking out joints, hacking for key & scrubbing down with water, etc. & removing rubbish outside MoD land complete all as specified and as directed.
Dismantling of cement concrete tiles,glazed tiles, terrazo tiles in floor, hearth or wall tiling including cement mortar bedding (but not backing), removing the rubbish outside MoD land complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 15 cm thickness below or above ground level including removing rabbish out side the MoD land complete all as specified and directed
Demolition of reinforced cement concrete any description as in roofs, floors (Other than ground floors), beams, staircases, landing, chajjas, slab, RCC water storage tanks & similar suspended work including removing rubbish out side MoD land complete all as specified and as directed.
M&L rendering 15 mm thick in CM 1:6 on brick masonry surfaces on fair faces of brick masonry finished even and smooth without using extra cement complete all as specified and as directed.
M&L rendering 15 mm thick in CM 1:6 on stone masonry surfaces or on other than fair faces of brick masonry finished even and smooth witout using extra cement complete all as specified and as directed.
M&L 15 mm thick rendering in cement mortar (1:4) plaster on stone masonary surfaces or other than fair faces finished even and smooth complete all specified and as directed.
M&L rendering 5mm thick in CM 1:3 as on concerete surface on ceilings, finished even and smooth without using extra cement complete all as specified and as directed .
M&L rendering 10mm thick in CM 1:3 n exc 3.00 sqm each patch in ceiling, in patches finished even and smooth without using extra cement complete all as specified and as directed
Roughning of old concrete floor by picking ,sweeping and washing down with water to remove dust etc completed all as specified and as directed.
M & L 25 mm thick PCC 1:2:4 type B-0, using 12.5 mm graded stone aggregate as in floors, surfaces finished fair and even complete all as specified and directed.
M&L Non- skid coloured ceramic matching tiles 7 to 8mm thick (square / rectangular) (Matt finish) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. Set & jointed in neat cement slurry & pointed in coloured cement to match the colour of tiles over complete & including 15mm thick screed bed in cm 1:6 completed all specified and as directed
M&L for non skid coloured ceramic matching tiles 7 to 8mm thick (square / rectangular) area of each tiles exc 0.11 sqm but not exceeding 0.18 Sqm in floor etc & jointed in neat cement slurry & pointed in coloured cement to match the colour of tiles over complete including 15mm thick screed bed in cm 1:6 all as specified and as directed
All as per item No 13 here in before but as in skirting and jointed in neat cement slurry & pointed in coloured cement to match the colour of tiles over and including 10mm thick as in back coat CM 1:4 complete all as specified and as directed .
M&L for light shade Vitrified Ceramic tiles 10 mm thick (square/ rectangular) double charge polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and jointed in neat cement slurry & pointed in coloured cement to match the colour of tiles over complete including 15mm thick screed bed in cm 1:6 complete all as specified and directed.
All as per item no 15 here in before but as in skirting and jointed in neat cement slurry & jointed in coloured cement to match the colour of tiles over complete and including 10mm thick as in back coat in CM 1:4 complete all as specified and directed .
M&L coloured Glazed ceramic tiles on verticle surface, size of tiles 300x600mmx7mm thick, (digital tiles) as dado etc laid in concept/pattern using highlighters set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles and including 10mm thick CM 1:4 complete all as specified and as directed .
M&L 15-16 mm thick Granite work (table rubbed & polished) in cooking plat forms,window cill & edges, steps, jamps, pillars in single piece and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match shade of granite complete all as specified and as directed.
M&L 12-14 mm thick Granite work (table rubbed & polished) in cooking platforms,window cill & edges, steps, jamps, pillars in single piece and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match shade of granite complete all as specified and as directed.
Rounding to edges of stone slab ( granite) two edges such as in cooking platform window cills, pillars etc including polishing to edge to give high gloss finish etc complete all as specified and as directed.
M&L Kota stone slabs, 20-25mm thick, machine cut as in coocking platform,thread of stair and flooring , set and jointed in cement slurry over and including screed bed of 20 mm thick in cement mortar (1:6) and pointed in cement mixed with pigment to match the shade of slab including rubbing, cutting complete all as specified and as directed
M & L for 25-30 mm thick Marble stone machine cut, bedded jointed as in verticle support and pointed with grey cement slurry including cutting complete all as specified and as directed.
S & F 18 mm thick HDWPC (High density wooden plastic composite ) Kitchen cupboard/door shutter of approved make one side colour/white laminate and other side decorative as in modular kitchen/ cabinets/door shutter fixed with minifix hardware where ever required including edge band 22 mm wide 0.80 m thick (of pearlwood or equivalent)of matching colour on exposed surfaces of board fixed with polymaster adhessive of approved make including trimming edges of edge band to true line of thicknesss of board by manual trimmer,fixed to wall etc complete all as specified and directed
S & F 8 mm thick HDWPC (High density wooden plastic composite) board of 'Pearlwood' or equivalent both side white laminate as in back of kitchen cabinets/partion of cupboard etc.complete all as directed
S & F kitchen plain baskets of stainless steel size 17" x20" x 4" of grade SS-304complete all as specified & as directed.(Make : Godrej, Hindware, Lifetime)
S & F kitchen prerforated cutlery baskets of stainless steel size 17" x20" x 4" of grade SS-304 complete all as specified and as directed.(Make : Godrej, Hindware, Lifetime)
S & F kitchen cup & saucer baskets of stainless steel size 17" x20" x 4" of grade SS-304complete all as specified and asdirected.(Make : Godrej, Hindware, Lifetime)
S & F kitchen plate baskets of stainless steel size 17" x20" x 6"of grade SS-304 complete all as specified & directed.(Make : Godrej, Hindware, Lifetime)
S & F kitchen grain baskets of stainless steel size 17" x20" x10" of grade SS-304 complete all as specified & directed.(Make : Godrej, Hindware, Lifetime)
S & F stainless steel basket guide channels suitable for running basket as mentioned in item 25 to 29 above of grade SS-304 complete all as specified & directed.(Make : Hettich )
S & F stainless steel Grade SS-304 handles of size 100 mm fancy type of approved make complete all as specified & directed. Make :- Ebco, hettich
S & F 4.8 mm thick glass not exc 0.5 sqm in each pane as in cabinet shutters fixed with beads of approved make complete all as specified & directed
S & F stainless steel Grade SS-304 handles of size 200 mm fancy type of approved make complete all as specified & directed. Make :- Ebco, Hettich
S & F stainless steel Grade SS-304 tower bolt of size 150 mm fancy type of approved make complete all as specified & directed. Make :- Hafle, hettich , Ultima
S & F 25mm dia stainless steel Grade SS-304 pipe with wall thickness 1.65mm of approved make fixed in wall /wooden surface etc.complete all as specified & directed.
S&F Auto close hinges, stainless steel Grade SS-304, bright finish or electro galvanised complete all as directed. Make :- Hafle, hettich , Ultima
S&F magnet for cupboard stainless steel Grade SS-304, bright finish or electro galvanised completed all as directed. Make :- Hafle, hettich , Ultima
S&F stainless steel Grade SS-304, bright finish or electrogalvanised cupboard lock with duplicate key all as specified and directed. Make :- Hafle, hettich , Ultima
S & F as in repair kitchen sinks made of stainless steel Grade SS-304 sheet 1mm th of grade SS-304 incl washer, brass sink coupling, waste pipe, bowl size 495 x 420 x160 mm fixed in kitchen granite top incl cutting granite/ marble of cooking platform compete all as specified and as directed
S & F as in repair stainless steel Grade SS-304 sink with draining board, made out of 1.00mm thick sheet for kitchen or laboratory with plug, washers waste pipe, cast iron cantilever brackets and fixed in kitchen granite top inclusive cutting granite / marble of cooking platform connecting union overall size 915mmx460mm with bowl size 450mm x 600mm x230 mm complete all as specifed and as directed.
Taking up or down 15mm bore steel tubing and connections including cleaning for refixing complete all as specified and directed
Taking up or down 20 mm bore steel tubing and connections including cleaning for refixing complete all as specified and directed.
Taking up or down 25 mm steel tubing and connections including cleaning for refixing or removal complete all as specified and directed.
S&F15 mm bore steel water tubing, galvanized, medium grade, with all fittings, fixed to walls and ceiling or in floor complete all as specified and directed.
S&F 20 mm bore steel water tubing, galvanized, medium grade, with all fittings, fixed to walls and ceiling or in floor complete all as specified and directed.
S&F 25 mm bore steel water tubing, galvanized, medium grade, with all fittings, fixed to walls and ceiling or in floor complete all as specified and directed.
Refixing only 15 mm bore steel water tubing galvanized medium grade concealed in all type wall with all fittings, fixed to walls and ceiling or in floor complete all as specified and directed. Note : Unit rate of this item also includes the cost of new fitting as required.
Refixing only after cleaning 20 mm bore steel water tubing, galvanized, medium grade concealed in all type wall with all fittings, fixed to walls and ceiling or in floor complete all as specified and directed. Note : Unit rate of this item also includes the cost of new fitting as required.
Refixing only after cleaning 25 mm bore steel water tubing, galvanized, medium grade concealed in all type wall with all fittings, fixed to walls and ceiling or in floor complete all as specified and directed. Note : Unit rate of this item also includes the cost of new fitting as required.
S&F as in repair bib taps 15mm bore cast copper alloy CP fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or for union complete all as specified and directed. Cat Part No :KUP- 35037PM of Make: Jaquar or Cat Part No : K-16093IN-4-CP of Make: Kohler, or Cat Part No : 20236000 Make: Grohe.
S&F as in repair bib taps 15mm bore 2-in-1 cast copper alloy CP fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or for union complete all as specified and directed. Cat Part No :KUP- 35041PM of Make : Jaquar or Cat Part No : K-20075IN-4-CP of Make: Kohler, or Cat Part No : 20281000 Make: Grohe.
S&F as in repair kitchen mixer 15mm bore cast copper alloy CP fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or for union for kitchen complete all as specified and directed. Cat Part No : FLR-5163 of Make : Jaquar,Cat Part No : K-99483IN-4-CP of Make: Kohler, or Cat Part No : 31232001 Make: Grohe.
S&F as in repair sink cock 15mm bore cast copper alloy CP fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or for union complete all as specified and directed. Cat Part No :FLR- 5347N of Make : Jaquar or Cat Part No : K-99482IN-4-CP of Make: Kohler, or Cat Part No :31228000 Make: Grohe.
S&F as in repair WHB mixer single lever 15mm bore swan neck cast copper alloy CP fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or for union complete all as specified and directed. Cat Part No :KUP- 35011BPM of Make : Jaquar or Cat Part No : K-72312IN-4ND-CP of Make: Kohler, or Cat Part No : 23090000 Make: Grohe.
S&F as in repair brass CP towel rail 60 cm long square complete all as specified and directed. Cat Part No :AKP- 35711PS of Make : Jaquar or Cat Part No : F870012 of Make: Hindware or Cat Part No : F5002103 Make: Cera
S&F as in repair Stainless Steel towel ring square including Chromium plated brass screws & plastic rawl plug complete all as specified and directed. Cat Part No :AKP- 35721P of Make : Jaquar or Cat Part No : F880007 of Make: Hindware or Cat Part No : F5002105 of Make: Cera.
S&F as in repair Soap dish, CP brass square fixed to plugs with chromium plated brass screws complete all as specified and directed. Cat Part No : AKP-35731P of Make : Jaquar or Cat Part No : F880011 of Make: Hindware or Cat Part No : F5007106 of Make: Cera
S&F as in repair Brass chromium plated shower rose with or without swivel joints, any size, including fixint to steel pipe or union complete all as specified and directed. Cat Part No : OHS-CHR-1605 of Make : Jaquar or Cat Part No : K-73198IN-CP of Make: Kohler, or Cat Part No : 26409000 Make: Grohe.
S&F as in repair Brass chromium plated shower arm ,including fixing to steel pipe or union complete all as specified and directed. Cat Part No : 479L300S of Make : Jaquar or Cat Part No :K-163461IN-CP of Make: Kohler, or Cat Part No : 27851000 Make: Grohe.
S & F as in repair 15 mm dia Angle valve, cast copper alloy chromium plated , screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions & fixed. Cat Part No :KUP- 35053PM of Make : Jaquar or Cat Part No : K-80154IN-CP of Make: Kohler, or Cat Part No : 22006000 of Make: Grohe..
S & F PTMT alloy bathroom cabinet with mirror of overall size 300 x 450mm complete all as specified and directed.
S&F as in repairs 15mm bore PVC connections, with PTMT nuts of length 450mm complete all as specified and directed.
S&F 15mm bore gate valve gun metal screwed down high pressure with iron wheel head screwed both ends for iron pipe or for union complete all as specified and directed.
S & F Glass Shelf 600mm Long complete all as directed . Cat No : AcN1171N of Make : Jaquar or Cat Part No : F870011 of Make: Hindware or Cat Part No : F5005301 of Make: Cera.
S&F 20mm bore gate valve gun metal screwed down high pressure with iron wheel head screwed both ends for iron pipe or for union complete all as specified and directed.
S&F in repair brass CP towel rack made by square/round pipes complete all as specified and directed. (Cat Part No : ACN-1181S Make : Jaquar) (Make: kohler,Cat Part No : K-99482IN-4-CP)(Make: GROHE,Cat Part No : 40462001)
S & F Single Lever Wall Mixer with Provision For Overhead Shower , Connecting Legs & Wall Flanges ,screwed the ends for iron pipe and plugging complete all as specified and directed. Cat part No OPP-15117PM of Make : Jaquar or Cat Part No : 23197000 of Make: Grohe or equivalent cat part in Kohler .
S & F as in repair 250 mm Corner Glass shelf with brass brackets
S&F as in repairs vitrous china squatting pan of size 580 x 440 mm (Orrisa pattern), white with integral foot rest(including fixing of flushing cistern & flush pipe) including antisyphonage pipe complete all as specified.
Supply only PVC low level cistern 10 litres capacity, valve less, symphonic action type with float, handle including 32mm dia PVC flush pipe of polyethylene of low or high density & bracket etc complete all as specified and directed .
S&F as in repair Single Piece-WC with soft close seat cover, Hinges, Fixing Accessories, Accessories Set and Cistern fittings, including P/S trap all as specified and directed . Cat Part No -LYS-WHT-38851S300UFSMN of Make : Jaquar or Cat Part No : K-77739T-SL-O of Make: Kohler equivalent cat part in Grohe
S&F brass CP health faucet 1.2m chain complete all as specified and as directed. Cat No : ALD-573 of Make : Jaquar or Cat Part No : F160013 of Make: Hindware or Cat Part No : F8030401AB of Make: Cera .
S&F brass CP toilet paper holder with flap complete all as specified and as directed. Cat No : AKP-35753PS of Make : Jaquar or Cat Part No : F880003 of Make: Hindware or Cat Part No : F5003110 of Make: Cera.
S&F as in repairs vitreous china wash hand basin white with pedestal white flat back including fixing taps, waste, chain & plug and porcelene stopper but including S&F brackets /fastners, cutting for and pinning in ends of brackets but inclussive of fixing of coupling and waste pipe/bottle trap. Note :- Supply of waste pipe , CP bottle trap ,CP waste coupling and grating shall me measured and paid seperately in respective item. Cat No :ARS-WHT- 39801 & ARS-WHT-39301 of Make : Jaquar or Cat Part No : 2017IN-1-0 of Make: Kohler, or equivalent in Grohe.
S & F 32mm as in repair bore brass CP coupling with long shank for wash hand basin. Make :- Jaquar/Kohler/ Grohe
Supply only 32 mm bore PVC waste pipe pf appropriate length of approved make (Prayag or equivalent)
Supply only brass CP bottle trap 32mm. Make :- Jaquar/Kohler/ Grohe
S & F in repair 15 mm dia stop cock ( concealed type) , cast copper alloy chromium plated , fancy type screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions & fixed complete all as specified and as directed. Cat No : KUP-35083KPM & ALD-083 of Make : Jaquar or Cat Part No : K-16087IN-4-CP of Make: Kohler, or Cat Part No : 29802000 Make: Grohe.
Demolition of brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles and removal all rubbish material outside of MD Land complete all as specified and directed.
M & L brick work using Subclass B old size bricks in exc. 6 m mean radius on plan built in cement mortar 1:6 complete all as specified and directed.
M & L brick work in half brick thick wall using Subclass B old size bricks built in cement mortar 1:4 complete all as specified and directed.
M&L walling of squared and regular random ruble uncoarsed stone masonary well bonded , bedded and solidly hearted built in CM 1:6 complete all as specified and directed.
M&L for raking out joints/pointing to stone masonary work in walls or to bricks on edge in floors, surface channels, roofs, etc. complete all as specified and directed
Dismantling of 75mm internal dia cast iron soil/ waste pipe alongwith fittings and accessories jointed in cement mortar and taking out from walls, floors or from trenches, if required complete all as specified and directed. Note : Excavation and earth work shall be measured and paid for separately.
Dismantling of 100mm internal dia cast iron soil/ waste pipe alongwith fittings and accessories jointed in cement mortar and taking out from walls, floors or from trenches, if required complete all as specified and directed. Note : Excavation and earth work shall be measured and paid for separately.
Dismantling of 75mm bore PVC soil/ waste pipe alongwith fittings and accessories jointed in cement mortar and taking out from walls, floors or from trenches, if required complete all as specified and directed.
Dismantling of 110mm bore PVC soil/ waste pipe alongwith fittings and accessories jointed in cement mortar and taking out from walls, floors or from trenches, if required complete all as specified and directed.
S&F 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or floors complete all as specified and directed
S&F 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to wallls complete all as specified and directed
S&F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or floors complete all as specified and directed
S&F75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to wallls complete all as specified and directed
S & F 75mm PVC (SWR) branch piece, single (single Y) equal or unequal complete all as specified and as directed.
S & F 110 mm PVC (SWR) branch piece, single (single Y) equal or unequal complete all as specified and as directed.
S&F 110 mm bore PVC (SWR) junction single (Single Tee with access door) equal or unequal complete all as specified and directed
S&F 110 mm bore bore PVC (SWR) bends any radius with access door complete all as specified and as directed.
S&F 75mm bore PVC (SWR) junction single (Single Tee with access door) equal or unequal complete all as specified and directed
S&F 75mm bore PVC (SWR) bends any radius complete all as specified and directed
S & F 110 mm bore PVC (SWR) bends with ducks foot complete all as specified and directed
S&F PVC (SWR) reducer (110 x 75 mm) complete all as specified and directed
S&F 110 mm bore PVC (SWR) vent cowl complete all as specified and directed
S&F 75 mm bore PVC (SWR) vent cowl complete all as specified and directed
S&F PVC (SWR) 75 mm dia of outlet nahani trap/floor trap with grating including jointing with solvent cement complete all as specified and directed
S& F PVC (SWR) gully traps of size 125/110 mm setting and jointing with solvent cement complete all as specified and directed
S&F PVC clamps for rain water , soil, waste pipe incl bolts if required for securing/ holding in position pipes of 75 mm complete all as specified and directed
All as per item no 104 - but 110 mm bore complete all as specified and directed
S & F as in repair stainless steel of grade SS-304 CP Grating doom 100 mm dia with waste hole complete all as specified and directed
S & F as in repair stainless steel of grade SS-304 CP Grating doom 100 mm dia complete all as specified and directed
Dismantiling of existing unserviceable tank and S&F 500 litres, rotational moulded polyethylene two layered ISI Marked water storage tank (Cylindrical vertical with closed top), white colour, hoisted and fixed in position including 20mm bore ball brass wall connecting pipes, nipple/ sockets etc complete all as specified and directed.
Dismantiling and S&F 1000 litres, rotational moulded polyethylene two layered ISI Marked water storage tank (Cylindrical vertical with closed top), white colour, hoisted and fixed in position incl connecting pipes, nipple/ sockets including 20mm bore ball brass wall, dismantling existing water tanks and removing tostore complete all as specified and directed.
Disconnecting existing tanks exc 250 ltrs but n exc 500 ltrs, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position including Cleaning and removing all scale and dirt, etc, from tanks and from mouth of circulating pipe etc (Note : charge of use of any type chemical used in tank cleaning will be taken care by contractor itself)
Disconnecting existing tanks exc 500 ltrs but n exc 1000 ltrs, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position including Cleaning and removing all scale and dirt, etc, from tanks and from month of circulating pipe etc (Note : charge of use of any type chemical used in tank cleaning will be taken care by contractor itself)
Taking down of shutter without taking off chowkhat and re-fixing after easing to shutters of any description exceeding 1 sqm and n.exceeding 2 sqm each in the same opening complete all as specified and directed.
Taking down chowkats or frames not exceeding 1.5 Sqm each with shutter (without taking off shutter from the frame) and removing from site complete all as specified and directed.
Taking down chowkats or frames exceeding 1.5 Sqm but not exceeding 4 Sqm each with shutter (without taking off shutter from the frame) and removing from site complete all as specified and directed.
Taking down shutter of any description exc. 1 sqm but n.exc 2 sqm each and removing from site complete all as specified and directed. .
S&F Pressed steel frames made of 1.25mm thick MS sheet of profile 125mm x60mm for doors with one or more rebates including necessary fixing lugs, 100mm MS hinges ,lock strike plate, etc including one shop coat of red oxide primer complete all as specified.(Note: 100mm MS hinges is provided as fixed with frame 3/6 nos as per requirement) and unit rate of highes are included in the quoted rates. Note :- 100mm MS hinges is provided as fixed with frame3/6 nos as per requirement and concrete for back filling in frame and for fixing holdfast PCC nominal mix 1:2:4 type B-0 considered in same and unit rate of hinge & PCC are included in this quoted rate.
S&F Pressed steel frames made of 1.25mm thick MS sheet of profile 105mmx60mm for doors with one or more rebates including necessary fixing lugs, 100mm MS hinges ,lock strike plate, etc including one shop coat of red oxide primer complete all as specified.(Note: 100mm MS hinges is provided as fixed with frame 3/6 nos as per requirement) and unit rate of highes are included in the quoted rates. Note :- 100mm MS hinges is provided as fixed with frame3/6 nos as per requirement and concrete for back filling in frame and for fixing holdfast PCC nominal mix 1:2:4 type B-0 considered in same and unit rate of hinge & PCC are included in this quoted rate.
S & F 35mm thick flush shutters solid core construction with block board and plywood face panels, fixed with approved adhessive incl lipping all round the edges of door as per manufacturers instructions
M&L for decorative laminate type 1, 0.9 mm thick colour and pattern as approved fixed as in door shutters completed all as specified and directed.
S & F 35mm thick second class hardwood factory made glazed and skeleton door shutters open rebated of second class hard wood rail and styles(Hollock), prepared to receive glass/gauge etc divided into square , with plain, chamfered or rounded, mitred and rebated sash bars any numbers , fitted with cut and mitred beads for securing glass/gauge etc. The size of rails & style as specified in SSR Part-I (2009) section 8 and as per IS-1003(Part-I) kiln seasoned as per IS-1141 and chemically pressure treated as per IS-401 complete all as specified and directed. Note :- S & F glass/gauge shall be measured and paid for separately
S & F 35mm thick factory made partly gauzed and partly panelled skeleton door shutters open rebated of second class hard wood rail and styles(Hollock), prepared to receive glass/gauge etc without sash bars, edges of framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass/gauge etc. The size of rails & style as specified in SSR Part-I (2009) section 8 and as per IS-1003(Part-I) kiln seasoned as per IS-1141 and chemically pressure treated as per IS-401 complete all as specified and directed. Note :- S & F glass/gauge shall be measured and paid for separately
S&F Stainless steel wire cloth, 0.36mm nominal dia of wire & average width of aperture 1.40mm & fixed to wodden door shutters with stainless steel wire staples complete all as specified and as directed.
S&F as in repairs Stainless steel wire cloth, 0.36mm nominal dia of wire & average width of aperture 1.40mm & fixed to wodden door shutters and any type of windows with stainless steel wire staples complete all as specified and directed.
S&F aluminium mesh of weight 0.55 Kg/Sqm pattern as approved as in support to SS wire cloth complete all as specified and directed
S & F solid PVC door frame of size 50mm x 47mm made out of 5mm wood grain painted PVC sheet reinforced with MS tube & fixing in opening as per specification and drawing.
S&F factory made PVC Moulded Door shutter, 28 to 30 mm thick (stiles), with 2, 4 or 6 raised panel design with 2mm thick moulded prelam PVC sheet on the front face and 2mm plain colour PVC sheet on back face and fixing in frame at site as per specification and drawing.
S &F Framed work such as grills, gratings, etc., with ends of bar shoulder &/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work of water tanks with Angle, MS sheet Flat iron & similar work conforming to Fe 290 GDE -E-165 (, SHEDS ,door frames and cooler stands etc) complete all specifed and directed
S &F Framed work such as grills, gratings, etc., with ends of bar shoulder &/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work of water tanks with Angle, MS sheet Flat iron & similar work conforming to Fe 290 GDE -E-165 , framed and hung as in gates incl pintle hinges , stops, hand made sliding bolts etc and for ornamental and intricate design complete all as specified and directed
S&F mortice lock for main door of Godrej locking solution and system ELC-06 -6 Lever door handle with loc set satin steel Make- Godrej or Equivalent in Modi and Link
S & F MS butt hinges 100mm size cold rolled medium weight and fixed as directed and specified and directed.
S & F as in repair MS butt hinges 50 mm size cold rolled medium weight and fixed as directed and specified and directed.
S&F in repair aluminium anodised sliding door bolt 250mm long with hasp and staple (bolt type) not less than 12mm dia with minimum 6 bolts and nuts , 4 bolt on plate and 2 on staple plate all as specified & directed
S&F in repair aluminium anodized barrel tower bolts 200mm long of extruded section all as specified & directed
S&F in repair aluminium anodized handle 150mm long, cast type all as specified & directed
S&F aluminium anodized barrel tower bolts 150mm long of extruded section all as specified & directed
S & F in repair 75 mm long door stopper of stainless steel body with two number rubber shoes complete all as specified and as directed.
S&F aluminium anodized barrel tower bolts 200mm long of extruded section complete all as specified and directed.
S&F aluminium alloy anodized handle 150mm long, cast type complete all as specified and directed.
S&F aluminium anodised sliding door bolt 250mm long with hasp and staple (bolt type and fixing clips of sheet or extruded section and fixing bolts and sliding bolt of extruded section complete all as specified and directed.
S & F 75 mm long door stopper of stainless steel body with two number rubber shoes complete all specified and directed
S & F MS Helical door spring150mm long including roller and roller plate complete fixed to angle iron chowkats. Complete all as specified and directed.
Casement fixed cum top hung window of area n exc 1 Sqm: uPVC window with having half bottom part fix and half top part openable glass sash with Stainless steel mosquito proof wiremesh all as specified and described in above item No. 142.
Casement openable window of area exc 1 Sqm but n exc 2 Sqm : uPVC window with single openable glass with Stainless steel mosquito proof wiremesh all as specified and described in above item No. 142.
Providing and fixing factory made uPVC white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net Opening will be measured lor payment purpose.) The slider three track windows shall be of following types:-
Sliding window of area n exc 2 Sqm:- uPVC window with having two glass sash panel inside one slider wiremesh panel all as specified in above item No. 143.
Sliding window with upside openable shutter for window AC/Cooler of area exc 2 Sqm:- uPVC window with having half bottom part having openable upside shutters portion fix with glass with having extra frame for fixing/provisioning of window AC/Cooler and half upper part with having two slider glass sash panel inside one slider wiremesh panel all as specified in above item No. 143.
S&F for 4 mm thick plain glass sheet odinary quality and glazing with neosprene beading or oil glass putty n.exc 0.5 Sqm in each pane.
S&F as in repair 25 mm dia stainless steel drapery rod grade 304 medium weight all as specified and as directed.
S&F SS -304 grade brackets/ end brackets for holding drapery rod with good quality SS finials for drapery rod 25 mm dia all as specified and as directed.
M&L preparation new or previously untreated steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over and including one coat of red oxide zinc chrome primer complete all as specified and directed
M&L preparation old painted steel surfaces of any description over 10 cm width or girth and applying one coats of synthetic enamel paint over complete all as specified and directed
M&L preparation new or previously untreated steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a already primered surface complete all as specified and directed.
M&L for preparation of new or previously untreated wooden or wood based surfaces of any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint over a already primered surface complete all as specified and directed.
M&L for preparation of new or previously untreated wooden or wood based surfaces of any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint over and including one coat of pink primer complete all as specified and directed
M&L for preparation of old painted wooden or wood based surfaces of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparing newly plastered surfaces and applying two coats of distemper with distemper oil emulsion white or tinted by mechanical means over a coat of primer over a coat of 1mm thick wall care putty to make smooth the undulated surfaces complete all as specified and directed. (Make : For wall putty- Birla white/Bison wall putty of Berger/Narolac wall putty/Asian paint powder putty /Acro wall guard.) Note:- The surface should be even and smooth after applying the wall care putty irrespective of number of coating applied and all as per directed.
M&L for complete removal of existing treatment from walls, including cleaning of any mortar drops, fungus efflorescent salts etc and preparation of old plastered surfaces and applying two coats of distemper with distemper oil emulsion white or tinted by mechanical means over a coat of primer over and including a coat of 1mm thick wall care putty to make smooth the undulated surfaces complete all as specified and directed. (Make : For wall putty- Birla white/Bison wall putty of Berger/Narolac wall putty/Asian paint powder putty /Acro wall guard.) Note:- The surface should be even and smooth after applying the wall care putty irrespective of number of coating applied and all as per directed.
M&L for preparation of newly plastered surfaces of wall and applying two coats of exterior emulsion paint by mechanical means over a coat of primer over 1-2mm thick (or as per Manufacturer instruction) wall care putty complete all as specified and directed. (make- Apex ultima of asian, weather shield max of ICI/Dulux) Note:- The surface should be even and smooth after applying the wall care putty irrespective of number of coating applied and all as per directed.
M&L Complete removal of existing treatment of old plastered surfaces of walls and washing, rubbing down and stopping of painted surfaces and applying two coats of exterior emulsion paint by mechanical means over a coat of primer over 1-2mm thick (or as per Manufacturer instruction) wall care putty complete all as specified and directed. (make- Apex ultima of asian, weather shield max of ICI/Dulux) Note:- The surface should be even and smooth after applying the wall care putty irrespective of number of coating applied and all as per directed.
M & L for preparation of old plastered surfaces of walls & applying two coats of white wash complete all as specified & directed
M & L for preparation of newly plastered surfaces & applying three coats of white wash on ceilings complete all as specified & directed
M & L complete removal of existing treatment of old plastered surfaces of ceilling and washing, rubbing down and stopping of painted surfaces & applying two coats of white wash complete all as specified & directed
M&L cement concrete Type B1 1:2:4 (20 mm graded aggregate,on lintels up to 1.5m clear span, bed plates,coping, kerbs water trough & the like including weathering, slightly rounded or chamfered angles & throating, complete all specified and directed
Taking down existing water proofing roof treatment of all description complete all as specified and directed.
M&L padding in PCC 1:2:4 type B-1 (20mm graded stone aggregate) laid to provide a required slope finished even & smooth without using extra cment complete all as specified and directed
M&L cement concrete in foundation type C 2, 1:3:6 ( 40 mm gde stone aggregate) as in filling and mass concrete.
Excavating in post holes (or similar holes) each n exc 0.5 cum getting out, all as specified and directed.
Cutting grooves in brick wall/stone wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3
M&L for surface preparation by removal of all loose particle to ensure clean, smooth and dry surface and laying 25mm thick PCC type B-0,( 1.2.4) using 12.5 mm graded stone aggregate finished even & smooth without using extra cement to cover negative slope into prop with WPC @ 3% weight of cement. Note : Water proofing compound shall be measured and paid seperately as supply only.
M&L rendering 10mm thick in cement mortar (1:3) on concrete surfaces to receive water proofing treatment finished even and fair complete all as specified.
Supply only liquid water proofing compund
S&F fiber reinforced UV resistant elastomeric liquid applied waterproofing & heat reflective coating with acrylic polymers and polyester/glass fibers after scraping and properly cleaning the surface to remove loose particles with wire brushes complete all as directed over a coat of primer as per manufacturers instr.
M & L for 75mm thick PCC 1:3:6 , type C-2 using 40 mm graded stone aggregate as in plinth protection laid in slope in 1:30 in alternative bays not exceeding 3 mtr in length. Exposed surfaces finished even and smooth without using extra cement including raking out joints between panel to panel and panel to wall and plugging the same with bitumen mastic using bitumen and sand mixture in 1:3 complete all as specified and directed .
M&L for 75 mm thick Cement concrete 1:4:8 type D-2, using 40mm graded stone aggregate as in sub base complete all as specified and directed.
M &L Machine pressed precast concrete interlocking paver block of any shape & size with grey cement and no pigments confirming to IS 15658 -2006 of 60mm thickness, M-35 Grade and including M&L 25mm thick river sand cushion complete all as specified and directed.
M & L for PCC solid blocks, kerb stones of size 300 x300x 150 mm factory made of PCC(1:2:4) type B-1 using 20 mm graded stone aggregate as in kerb stone set in CM 1:4 complete all as specfied and directed.
M&L two coats of synthetic enamel paint over a coat of primer on new concrete or plastered surfaces including preparation of surfaces as on kerb stones complete all as specified and directed
M&L for chequered tiles cement concrete tiles 200x200x25mm thick, set jointed & pointed in neat cement slurry in floors with grey cement & pigment over 20mm thick screed bed in cm 1:6
M & L for Terrazzo tiles 200mm x 200mm x 20mm thick, with size of chips upto 12 mm; set, jointed and pointed in neat cement slurry in floors, and cut and polished including 15mm thick screed bed in CM 1:6 complete all as specified and directed
S & F as in repair Plate rack of size 900mmx750mmx250mm fabricated out of 1mm thick stainless steel sheet fixed in repair complete all as specified and directed.
Dismantling plain or corrugated steel / FRP sheeting any gauge, thickness including nainital or similar pattern roof /wall covering
S & F pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering / cladding to wall, fixed with self tapping screws as specified and directed.
S & F steel work in tubular/ square/ rectangular trusses incl special shaped washer etc, complete using ERW or induction butt welded tubes conforiming to IS 1161-1979 graded St-240 complete all as specified and directed.
M & L form work to sides of concrete foundations, footings, bases of columns, sides & soffits of foundation and plinth beams and similar work for rough finished flat surfaces of concrete complete all as specified and directed.
M & L form work to sides of square or rectangular columns, pillars, posts and struts for rough finished surfaces of concrete square, rectangular or polygonal complete all as specified and directed.
M & L RCC nominal mix 1:2:4 type B1(using 20 mm graded stone aggregates) in foundations, footing, plinth beams, bases for columns and mass concrete complete (reinforcement to be measured separately).
M& L RCC nominal mix 1:2:4 type B -1(using 20 mm graded stone aggregates) in columns, pillars, posts & struts complete (reinforcement to be measured separately) complete all as specified and directed
M & L for 10 mm thick rendering in CM 1:3 for laying wall finishes (granite for gate pillars) etc. complete all as specified and directed.
Excavation in trenches n.exc 1.5m wide & n.exc 1.50m in depth for foundation , etc or for shafts, wells, cess pits, man holes,pierholes etc n. exc 10 sqm on plan & getting out in hard/dense soil. Note :- Excavation shall be done manually.
M&L PCC 1:4:8 Type D2 (40 mm graded aggragate) as in foundation, filling and mass concrete complete all as specified and directed
S&F MS TMT bars 10mm dia & over cut to length bent to shape reqd incl cranking, bending spirally for hooping for cols, hooking ends and binding with steel MS wire (annealed) not less than 0.9 mm dia.
All as per item No 191 above but for 5mm dia and over upto and incl 10mm dia in stirrups, spacers and binders.
Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point.
S&F steel windows factory made, out of MS hollow section 79mmx39mmx1.6mm thick frame with double shutter (glazed & welding and tennon riveting all as per IS 1038/83, dobby hinges shall be provided to both shutters, Locking arrangements as per sample approval by GE provided with knob, 10mm MS square bars in grill, Z section handle 100mm size and 150mm long hook & eye welded to frame and shutter, four Nos lugs welded to frame including necessary flat iron beading for securing wire gauge etc including holes, cutting holes for hold fast and making good in PCC 1:2:4 type B-1 complete all as specified and directed. Note : Wire mesh and sheet glass shall be measured & paid separately under respective items.
S&F as in repair Steel ventilator with top hung shutter with out glazing bars to receive wire gauge etc including hinges steel peg stay etc including one shop coat of red oxide primer complete all as specified and directed.
S&F 3mm thick frosted glass pin head type and glazing with oil putty in squares not exc 0.5 sqm in each pane complete all as specified and directed
Cutting holes into or through cement concrete slabs, chajjas etc reinforced or otherwise superficial area not exc 100 Sqcm complete all as specified and directed
M&L Cutting holes in stone masonry walls in cement mortar & making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required superficial area exc 150sq. cm but not exc 400 sq. cm complete all as specified and directed
S&F PVC (SWR) 50mm bore pipe single socketed in any length with rubber ring joints fix to wall complete all as specified and directed
M&L for precast cement concrete 1:2:4 type B1 (20mm gr stone aggr) as in man hole covers, landings etc set in cm 1:4
Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified
Dismantling of loose reinforced cement concrete any description by chieseling , wedging etc. cutting the unserviceable reinforcement as in roofs, floors (including ground floors), beams, staircases, landing, chajjas, slab, similar suspended and columns work complete all as specified and directed incl removal all rubbish material where directed. Note : The work may allowed carried in patches and noting extra shall payable on this account. (ii) Unit rate of this item including for trimming bottoms and sides of cut surface.
Providing and erecting steel props (up to full height, braced at centre, resting on wedge and block to support the structure provisionally during repair work and maintaining them in position till required and as directed by the Engineer-in-Charge
Chipping of unsound weak and cracked concrete/cover of reinforcement over RCC member or as per site requirement by chieseling and disposal of malwa from site as per instruction of Engineer-in-Charge.
Cleaning of exisiting reinforcement with wire brush/rotary wire brush to make surface free from rust scales, loose material, diet etc, complete and proving, applying two coats of alkline rust converting primer on the existing rebar and allowing it to react with rust for 6 hrs and forma corroson resistant, insoluable and adherant protective layer, including cleaning the reinforcement, wire brushing to remove the rust spalls, with time interval of 1 hour between the coats. Make :- Sika/Fosroc/Thermax
Providing and application of corrosion inhibiting impregnation coating, designed for use as an impregnation for protection of steel reinforcment within unexposed concrete with in consumption of 0.5 kg/m2. The product should be amino alcohol and inorganic combination based migratroy corrosion inhibitor for both cathodic and anodic protection. Make :- Sika/Fosroc/Thermax
Providing and application of zinc rich epoxy antocorrosive protective coating for rebar corrosion protection system complete all as specified and as directed. Make :- Sika/Forsoc/Thermax
Making 'V' groove of 5mm wide and 5mm deep over crack line by electrically operated angle grinder with diamond concrete saw blade and cleaning it by air blower and Sealing of exposed 'V' groove of 5mm deep and 5mm wide with solvent-free, moisture tolerant thixotropic, two part structrural adhesive and repair mortar, based on epoxy resins and special fillers, designed for use at temperatures between +10°C and +40°C, having conforms to ASTM C 881-78, Type I, Grade 3, Class B+C, compressive strength >60 N/mm2 (14 days) according to ASTM C 881 : bond strength > 10 N/mm² (7 days) according to ASTM C 882. Make :- Sika/Fosroc/Thermax
S&F MS TMT bars 6 mm to 8 mm dia cut to length bent to shape reqd incl cranking, bending spirally for hooping for cols, hooking ends and binding with steel MS wire (annealed) not less than 0.9 mm dia.
S& F hard drawn steel wire fabric exc. 4 kg/Sqm weight cut to length bent to shape required and tying with & incl mild steel wire (annealed) not less than 0.9 mm dia as in reinforcement. Complete all as specified and directed. Note : Rates also includes for straighteing and wastage extc
M & L for Rebulilding the section of damaged RCC elements to its original size in thickness of 100mm by providiing and casting with ready to use non shrink. Cementitious free flow micro-concrete having compressive strength > 60 N/mm2 (28 days) according to ASTM C 1107-99 including providing and fixing of watertight foam faced finish shuttering of minimum 18mm thickness and supporting formwork, all lead fit, mixing, placing, de-shuttering, levelling the surface by grinding off cementitious slurry or cementitious joints diferences if any for satisfaction of Engineer-in-Charge and cruing.curing thereof. Note : Dry unit weight of microconcrete shall be measured. Make :- Sika/Fosroc/Thermax
Use and waste of form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick finish with rough finish flat surface. Complete all as specified and directed.
Use and wastage of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelvves including sup-ports, overhangs, etc. also splays between floors and beams, etc finish with rough finish flat surface.
Use and waste of form work to chullah hoods, chajjas, troughs and similar items including edges finish with finish flat surface.
Use of waste of Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work n exc 20cm wide with rough finished surfaces complete all as specified and directed.
Providing, mixing & applying two component Epoxy resin concrete Bonding coat on prepared RCC surfaces as per manufactrure specification including prepartation of surface by chipping and throughly cleaning of surface complete wherever required and as per complete all as directed and specified. Make :- Sika/Fosroc/Thermax
M & L for Rebulilding the section of damaged RCC elements to its original size on an average 15mm thickness in two layers each by providing and applying with pre-batched, polymer modified mortar of approved make having compressive strength >= 50 N/mm2 (28 days) according to ASTM C 109: Flexural strength >= 5N/mm2 (7 days) according to ASTM C 293-79 complete all as specified and as directed. Make :- Sika/Fosroc/Thermax
M & L for Rebulilding the section of damaged RCC elements to its original size on an average 15-30mm thickness in two layers each by providing and applying with pre-batched, polymer modified mortar of approved make having compressive strength >= 50 N/mm2 (28 days) according to ASTM C 109: Flexural strength >= 5N/mm2 (7 days) according to ASTM C 293-79 complete all as specified and directed. Make :- Sika/Fosroc/Thermax
Supply and apply water dispersed, acrylic copolymer based concrete curing compound for the prevention of premature water loss from concrete with consumtion of 5 to 6.5 m2 per litercomplete all as specified and directed. Make :- Sika/Fosroc/Thermax
Drilling holes of 12mm dia, up to 100 mm deep holes in structrual members at the iterval of 300mm in staggered manner or along the crack line as directed in reinforced concrete (RC) structural element including cleaning of the holes by air blower and inserting 12mm dia NRV (Non Returnable Valve) nozzle compatitable with epoxy injector and having machined external end to receive outlet of Grouting Gun. Fix it inside the hole by applying thixotropic epoxy putty to ensure complete sealing and allow to cure the system for minimum of 8 Hrs before Grouting including nozzle projections, excess putty, if any, over concrete element by grinding, levelling and difinsihing the external surfacr after completion of the work etc complete. Make :- Sika/Fosroc/Thermax
Grouting injecting two part, low viscosity, moisture insensitive injection-liquid, based on high strength epoxy resin by pressure and using pressure epoxy injector with accessories till nozzle refused to accept the grout including mixing of grout having mixed density should have below properties. Compressive strength >= 70 N/mm2 (7 days) according to ASTM C 579 : Tensile Strength ~ 50 N/mm2 (after 7 days at +30º C cure) According to ASTM D 638 :Tensile moduls ~2000 N/mm2 (after 7 days at +30 º C cure) According to ASTM D 638 : Bond strength ~ 10.8 N/mm2 (failure in concrete) after 14 days at +30°C cureC cure) According to ASTM D 638 : Bond strength ~ : Flexural strength ~50 N/mm2 according to ISO 178 . Seal the nozzle with thixotropic epoxy putty after the refusal of grout material from the nozzle. Note :- leakage through other nozzle or cracks are required to be monitored while grouting and such points to be sealed as and when required without any extra cost. complete all as specified and as directed Make :- Sika/Fosroc/Thermax
M&L RCC M - 25 (Design Mix) (20 mm graded stone aggregate) stone aggregate as in Chajjas complete all as specified and as directed.
M&L RCC M - 25 (Design Mix) (20 mm graded stone aggregate)as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
Taking down carefully surface aluminium or copper point wiring with PVC casing or conduit (light, fan, socket, bell or power) including fixture and fittings such as switches, ceiling roses, regulators, sockets, light fittings etc and making good disturbed surfaces of walls, floors, etc all as directed. Note :- Serviceable tubelight fittings shall be reused as refixing under respective item of BOQ.
Taking down and dismantaling Ceiling fan including accessories of any type or make,safely and refixing after oiling greasing and servicing in serviceable condition duly painted by synthetic enamel paint of in white/off white colour including writing MES number complete all as specified and directed .
Taking down and dismantaling exhaust fan including connected accessories of any type or make,safely and refixing after oiling greasing and servicing in serviceable condition duly painted by synthetic enamel paint of in greyish/smoky greyish in colour including writing MES Number complete all as specified and directed.
Taking down and dismantaling geyser including connected accessories such as PVC connection pipe and etc of any type or make,safely and refixing after oiling greasing and servicing in serviceable condition duly painted by synthetic enamel paint of existing colour of the same colour including writing MES Number complete all as specified and directed .
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 1.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and terminated in modular metal flush boxes for mounting switches, sockets, fan regulator as required for one light point controlled by one switch.( Note :- The cost of cutting chases in stone masonary and making good disturbed surfaces using CM 1:3 shall deemed to be included in quoted rate of the concealed wiring.) Notes:_ (a) The cost of modular metal flush box & modular cover plate colour and size as required at site and cutting chases in stone masonary and making good disturbed surfaces using CM 1:3 shall deemed to be included in quoted rate and the make of modular plate shall be of the same make as per switch socket accesories. (b) Modular switch/socket accessories shall be measured and paid seperately in respective item.
All as per item No. 228 here-in-before but one fan point controlled by one switch
All as per item No. 228 here-in-before but one Exhaust fan point controlled by one switch
All as per item No. 228 here-in-before but one light point controlled by two, two way switch.
All as per item No. 228 here-in-before but One socket outlet 6 amp controlled by one switch on indepdendent board.
All as per item No. 228 here-in-before but One bell point controlled by on bell push button.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 4.0 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 4.0 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and terminated in modular metal flush boxes with modular white cover plate with frame for one socket point 16 Amps controlled by one switch on indepdendent board. complete all as specified and directed Notes:_ (a) The cost of modular metal flush box & modular cover plate colour and size as required at site and cutting chases in stone masonary and making good disturbed surfaces using CM 1:3 shall deemed to be included in quoted rate and the make of modular plate shall be of the same make as per switch socket accesories. (b) Modular switch/socket accessories shall be measured and paid seperately in respective item.
M&L for provn point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 1.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and terminated in modular sunken boxes for mounting switxhes, sockets, as required One socket outlet 6 amp controlled by one switch on the same board with other switches. complete all as specified and directed. Notes:_ (a) The cost of modular metal flush box & modular cover plate colour and size as required at site and cutting chases in stone masonary and making good disturbed surfaces using CM 1:3 shall deemed to be included in quoted rate and the make of modular plate shall be of the same make as per switch socket accesories. (b) Modular switch/socket accessories shall be measured and paid seperately in respective item.
S&F angle holder 6A, 240V insulated polycarbonate body with back plate complete all as specified and directed
S&F switch modular 1 way 6 Amps, 230 volts, 1 module. Complete all as specified and directed
S&F modular socket 6 Amps, 2/3pin combined 2 module AC 230 volts complete all as specified and directed.
S&F modular switch 1 way 16/20 Amps, 230 volts, 1 module complete all as specified and directed
S&F modular socket 6/16 Amps, 2/3pin combined 2 module AC 230 volts. Complete all as specified and directed.
S&F modular fan regulator 120 watts, 2-module AC 230 Volts. Complete all as specified and directed.
S&F switch modular 2 way 6 Amps, 230 volts, 1 module complete all as specified and directed.
S&F Modular bell push 6A 1 module complete all as specified and directed.
S&F musical bell, AC, 230 volts, single pole complete all as specified and directed.
S&F ceiling rose 3 pin (phase, neutral and earth) polycarbonate body complete all as specified and directed.
M&L as in repair submain wiring alongwith earth continuity conductor with PVC insulated FRLS multistranded copper conductor cable (Phase - Red, Neutral - Black, Earth - Green) drawing into and including concealed rigid non metallic PVC conduit, medium grade, ISI marked ivory colour along with accessories size 2X6 sqmm + 1X6sqmm earth wire in 20 mm dia conduit.and terminnated in power socket, DBs, panel etc all as directed. (Note 1:- Two runs of 6 Sqmm copper wire and one run of 6 sqmm copper earth wire alongwith conduit shall be meausred as one unit) (Note2:- Rate of cutting , chasing of existing wall and making good disturbed surface for concealed conduit shall be includwd in this item)
M&L as in repair submain wiring alongwith earth continuity conductor with PVC insulated FRLS multistranded copper conductor cable (Phase - Red, Neutral - Black, Earth - Green) drawing into and including concealed rigid non metallic PVC conduit, medium grade, ISI marked ivory colour along with accessories size 4X6 sqmm + 2X6 sqmm earth wire in 25 mm dia conduit and terminnated in power socket, DBs, panel etc all as directed. (Note :- Four runs of 6 Sqmm copper wire and two run of 6 sqmm copper earth wire alongwith conduit shall be meausred as one unit) (Note2:- Rate of cutting , chasing of existing wall and making good disturbed surface for concealed conduit shall be includwd in this item)
S&F 20 amp, single pole and neutral socket outlet with 2 pole and earthy, metal enclosed plug top in power coated CRCA steel sheet enclosure recess mounted with cchained metal cover for socket outlet with and including one number single pole 'C' series MCB 16 amp as required. Make- Legrand/Hager/Schneider as approved.
M&L as in repair for earthing with galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised iron strip 32mm x 6 mm earth lead by means of steel bolts, nuts, check nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I connected to earthing point and testing on completion with and including 40 mm bore light grade G.I. protection pipe (upto 7.5 metre beyond outer edge of earth pit) PCC pit in mix 1:3:6 type C1 with RCC 1:2:4 type B-1 40 mm thick cover reinforced with 6 mm dia M.S bars 3 Nos both ways with lifting hook made out of 6 mm dia bar, watering arrangement with funnel and wire mesh and 20 mm bore light grade G.I. watering pipe, common salt and charcoal filling, necessary excavation and earth work complete all as specified and directed. Note :- Excavation for earthing shall be done manually and earth resistance below 3 Ohm should be obtained after measurement for every pit .
M&L Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32mm x6 mm galvanised iron strip compelete all as specified and directed
S&F as in repair MCB distribution board, powder coated, SPN , 240 volts, 4 ways,CRCA steel sheet, degree of protection IP 43 - IK 09 with reversible double door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required. Make :Legrand Cat No: 5076 or equivalent make given in Appx 'B' as approved by GE.
S&F as in repair MCB distribution board, powder coated, TPN , 415 volts, 4 ways,CRCA steel sheet, degree of protection IP 43 - IK 09 with reversible double door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required. Make:-Legrand Cat No: 5076 or equivalent in make given in Appx as approved by GE.
S&F MCBs of 'B' series having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs of Single pole 6 to 32 amp.
S&F MCBs of 'C' series having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs of Double pole 10 to 32 amp.
S&F RCBO, rated current 40 amp, rated residual current 30mA, rated voltage - 415 V AC (3P+N) residual current off time <=0.3 sec standard : IS 12640 (part2) : 2001 & IEC : 61009-2-1, breaking capacity - 10 KA, Endurance - electrical - 4000 operation , Mechanical - 10000 operating, terminal protection - IP20 complete All as specified & directed. Make - ABB, HAGER, LEGRAND.
S&F as in repair LED fixtures with extruded polycarbonate, environmental friendly, slim design with decorative and caps, high performance diffuser for soft & glare free light, minimum lumen output 1900 lm with efficacy 110 lm/w. Driver with high voltage protection upto 380 VAC & surge protection upto 2.5 KV, CCT (K)-6500, LM 80 tested high brightness LED technology. Make cat Part No:- Wipro Cat No D532065, Havells Cat Part No :- LHEXAWP71N1W020 or eqt phillips.
S&F as in repair LED fixtures with extruded polycarbonate, environmental friendly, slim design with decorative end caps, high performance diffuser for soft & glare free light, minimum lumen output 900 lm with efficacy 110 lm/w. Driver with hgih voltage protection upto 380 VAC & surge protection upto 2.5 KV, CCT(K)-6500, LM 80 tested hgih brightness LED technology. Make cat part No :- Wipro Cat No D-531065, Havells Cat part No :- LHESACP71N1W010 or eqt philips.
S&F as in repair LED 25 watt street light smartbrite aluminium PDC housing with IK 07 protection PC glossy diffuser duly prewired connection having a nominal system lumen output or efficiency 100 lumens/watt light watt and total power consumption not more than 25 watt including driver. It has a rated IP 66 with 5 KV inbuilt surge protectione. Make cat part No Havells ENDURAPEARLSL25WLED757SASYTOPCMP, Syska/Wipro
S&F 10 watt LED T-lamp B-22 base (warm white/golden yellow) 1000 lumens, Make : Philips Cart Part no 9290018611 or equivalent in Havells/Bajaj as approved
S&F PVC fresh air fan 250 mm sweep, 230 V with louvers, fan motor and accessories complete including making connecions. Make : Crompton, Havells, Khaitan
S&F as in repair surface mounted LED panel with opal diffuser and separate Electronic driver for 12 Watt, 240V, slim compact aluminium die cast edge lit panel, 6500K 1200 lumen output having luminous efficacy. Make :- Wipro cat part No :- LD80-101-XXX-60-SM or eqvt of philips/ Havells
S&F ceiling fan type 1200 mm sweep 50 Hz AC 230 volts, BEE 5 star rated in white colour with fan moter, blade set, 0.45 mtr down rod, canopy. Make : cat part Havells ES-50, CG, Orient.
Supply, installing, testing and commissioning stationary storage type electric water heater (geyser) 25 ltr capacity BEE 5 star rating inbuilt current leakage protection device, multifuction safety valve, high precision thermostat control, Preset thermal output, high working pressure 0.8 MPa, vertical mounting including min 2 yrs warrenty. Make : Havells Model - Havells Model - Monza 25 Lt or equivalent cat part in RACOLD, V GUARD or make specified in Appendix 'B'.
Refixing only tube light fitting/surface fitting /security light fitting as obtained from above item ser No 224 complete with all assories internally pre-wired and and including connecting up with with twin core twisted flexible coper conductor cable with suitable size complete all as specified and directed.
Supply, installation, testing and commissioning as in repair factory made CPRI approved and tested, LT feeder pillar box(Kiosk), indoor type, platform mounted, suitable for 415 V 3 phase and neutral 4 wire, 50 Hz ac supply system having busbar chamber with insulated aluminium busbars of 300 Amps rating in color code RYB with 3 phase and neutral installed on porcelain insulators with busbar chamber. The panel shall be dust and vermin proof , protection class IP 42 and made of 2 mm thick CRCA MS sheet and MS angle iron frame work( made out of 40mmX40mmX6mm thick), powder coated finish on outside surface and powder coated finish inside surface (of approved shade ), compartment type aprons for cable entry and internal wiring with PVC insulated solid copper conductor, FRLS cables,IS-694 marked of adequate size not less than 4 sqmm with proper ferrule & gland complete and also comprising of the following :- Incoming :- One number MCCB 125 Amps 4 pole 16 KA 415 volts, 70-100%, 50 Hz . Make Legrand Cat No. 4200 16 or equivalent in Hager/Schneider. Outgoing :- (a) MCB TPN 63 Amps 'C' series 10 KA AC AC 240 Volts 04 Nos Make Legrand Cat No. 4086 83. or equivalent in Hager/Schneider. (b) MCB DB 20 Amps 'C' series 10 KA AC 240 volts - 01 Nos Make Legrand Cat No. 408631 to 408636. or equivalent in Hager/Schneider. (c) Three phase tamper proof meter with optical port 10 to 60 Amps :- 04 Nos .Make : HPL Cat No TPPL 1810000000OCN0 Note : Existing old energy meter shall be deposited at MES yard. (d) Fixing arrangement using angle iron 40X40X6mm mounting on floor upto height 0.6 m from floor level. Grouting of angle iron from should be in appropriate depth( not less than .30 m) including necessary excavation and PCC work (e) Existing LT cable. to be coonected with LT panel and outgoing connection to be prepared as per direction of Engr-in-Charge
SHREE MEGHALAYA CONSTRUCTION AND SUPPLY COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .