Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.2 LAccepted-AOC OFFICE NO 101 MALAN PLAZA NEXT TO ESSAR PETROL PUMP NEAR GODAMBLE CORNER RAHATNI PIMPRI DP ROAD RAHATANI PUNE 411 017 | PUNE | PUNE | MAHARASHTRA | 411017 | L1 | Accepted-AOC THE LOWEST TENDERER | |
| 2 | L2₹12.6 L+₹1.5 L (13.1%)Rejected-Finance FLAT NO 203 SEC 14 PLOT NO 142 SHIVSRUTI PARK APARTMENT E WING 1ST FLOOR MOSHI PRADHIKARAN TAL HAVELI DIST PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L2 | Rejected-Finance NOT THE LOWEST TENDERER |
Tender Value
Refer Docs
EMD Value
₹28,000
Closing Date
22 May 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE MH AND RH KHADKI
Military Engineer Services Garrison Engineer MH and Range Hills Range Hills Road Khadki, Pune 411003
REPAIR AND MAINTENANCE OF COOLING APPLIANCES AREA UNDER DGQA AND GE MH AND RH KHADKI
2023_MES_583825_3
8413/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE MH AND RH KHADKI
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE MH AND RH KHADKI
₹28,000
5 Sept 2023
2 May 2023
24 May 2023
2 May 2023
22 May 2023
9 May 2023
2 May 2023 - 15 May 2023
Amount
Comprehensive maintenance and servicing of Refrigerator/Deep Freezer/ Split type Air conditioner / Window type unit of any capacity outer and inner unit both of any make including cleaning the dust from body with blower, cleaning of condenser and cooling coil, checking all connectins including functioning of metal clad socket/DP switch, function of relay, capacitors, overload protector, thermostat, fan motor, fan motor blade/blower drum, main control board PCB, electronic control box, etc, oiling/greasing of fan motor, checking serviceablility, cleaning of the air filter woolen felt & refixing ensuring for air tighting complete, repair and replacement of worn out/unserviceable spares including taking down and refixing, transportation to and from workshop if required and refixing it in its original place after fully servicing including testing and cleaning of area & commissioning all as specified and directed by Engineer-in-Charge. Note: (i) Spare parts to be replaced shall be measured & paid separately as supply only under relevant item of this BOQ. (ii) Supply and charging of Nitrogen /Refrigerant gas will be measured and paid separately under relevant item of this BOQ.
Supply only starting capacitor 80-100 Mfd 440 Volts AC, 50Hz for window /split AC of capacity 1.0 / 1.5 TR for AC all as specified and directed of existing make.
Supply only starting capacitor 120 Mfd 440 Volts AC, 50Hz for window /split AC of capacity 2.0 TR for AC all as specified and directed of existing make.
Supply only running capacitor 36 Mfd 440 Volts, 50 Hz AC for window / split type AC of capacity 1.5 TR.
Supply only running capacitor 50 Mfd 440 Volts, 50 Hz AC for window / split type AC of capacity 1.5 TR / 2.0 TR
Supply only blower motor capacitor 4 Mfd 440 Volts, 50 Hz AC for window / split type AC of capacity 1.5 TR / 2.0 TR
Supply only blower motor capacitor 6 Mfd 440 Volts, 50 Hz AC
Supply only running capacitor 25 Mfd 440 Volts, 50 Hz AC for water cooler.
Supply only for over load relay comprising of over load protection suitable for air conditioner, water cooler, deep freezer and refrigerator operated in single phase 230 volt all as specifed and directed.
Supply only thermostat switch suitable for Air conditioner, water cooler, Deep freezer and Refrigerator operator on single phase 230 volts supply all as specified and directed.
Supply only drier filter for AC, water and Refrigerator.
Supply only magnetic contactor as in outer unit of Split type air conditioner as per existing type complete all as specified and directed.
Supply only capillary tubes for the Air conditioner 1.5 Ton / 2 ton and water cooler 40 to 150 Ltrs
Supply only indoor fan motor of split type AC of any capacity
Supply only condensor fan motor 1300 rpm, 1/6 Hp, 1/8 Hp, 1/10 Hp for split type Air conditioner outdoor unit of 1.0 Ton/1.5 Ton/2.0 Ton as per existing make and capacity all as specified and directed by Engineer in charge
Supply only condensor fan motor double shaft 1/4 Hp, 230 Volts AC for Window type AC of 1.0/1.5 Ton/2.0 Ton (indoor unit) as make and capacity all as specified and directed by Enginner in charge
Supply only condensor fan motor double shaft 1/5 Hp, 230 Volts AC for Window type AC of 1.0/1.5 Ton/2.0 Ton (indoor unit) as make and capacity all as specified and directed by Enginner in charge
Supply only condensor fan motor double shaft 1/6 Hp, 230 Volts AC for Window type AC of 1.0/1.5 Ton/2.0 Ton (outdoor unit) as make and capacity all as specified and directed by Enginner in charge
Supply only condensor fan motor double shaft 1/8 Hp, 230 Volts AC for Window type AC of 1.0/1.5 Ton/2.0 Ton (outdoor unit) as make and capacity all as specified and directed by Enginner in charge
Supply only condensor fan motor 1/36 Hp for water cooler of 40-80 Ltr and Deep freezer up to 400 Ltr as per existing make and capacity all as specified and directed by Engineer in charge
Supply only condensor fan motor 1/6 Hp, 1/8 Hp, 1/10 Hp for water cooler of 120-150 Ltr as per existing make and capacity all as specifed and directed by Engineer-in-Charge
Supply only remote control unit of Splity type AC 1.5 Ton / 2.0 Ton including making frequency arrangement of new remote with existing system all as specified and directed by Engineer-in-Charge
Supply only Electronic PCB unit for main control panel of splity type/window type AC of any capacity
Supply only capillary tubes for the refrigerator & deep freezer up to 400 Ltr
Supply only starting relay suitable for water cooler, AC and Refrigerator, Deep freezer for any make and model operated on single phase 230 volts all as specified and directed.
Supply only thermostat switch suitable for Air conditioner, water cooler, Deep freezer and Refrigerator operator on single phase 230 volts supply all as specified and directed.
Supply only condensor fan motor 1/36 Hp for water cooler of 40-80 Ltr and Deep freezer up to 400 Ltr as per existing make and capacity all as specified and directed by Engineer in charge
Supply only blower/condenser fan blades as per existing make & type for Air conditioner/water cooler/Deep freezer all as specifed and directed.
Supply only starting capacitor 10 Mfd 440 Volts, 50 Hz AC for water cooler.
Supply only running capacitor 15 Mfd 440 Volts, 50 Hz AC for water cooler.
Supply only starting capacitor 60 Mfd for water cooler
Supply only starting capacitor 80 Mfd 440 Volts, 50 Hz AC for water cooler.
Repair, replacement and supply, install, test & commissioning harmetically sealed New compressor for the following appliances duly charged with fresh freon gas / R-134 a complete all as specifed and directed by Engineer-in-Charge including taking down old u/s compressor. Make: Voltas/Shriram/LG/Godrej/Kirloskar or as per existing make at site.
Split type AC of capacity 1.5 TR
Split type AC of capacity 2.0 TR
Window type AC of capacity 1.5 TR
Water cooler of capacity 40 to 80 Ltrs
Water cooler of capacity 120 to 150 Ltrs
Refrigerator 165 to 210 Ltrs
Refrigerator 210 to 310 Ltrs
Deep freezer upt 200 to 400 Ltrs
M & L for Detecting the gas leakage with the help of nitrogen gas, rectifying the defects including repair to condensor coil/evaporator coil by means of welding, soldering etc, vacumizing and charging, topping up fresh freon Gas/ R-22 a and commissioning and testing for the 1.5 Ton/2.0 ton split /window type AC all as specified and directd by Engineer-in-Charge
All as per item No 3 above, but of water cooler/ refrigerator/ deep freezer of any capacity for servicing and gas charging .
All as per item No 3 above for complete servicing of Water cooler / Deep Freezer/ refrigerator
Comprehensive maintenance and service of cold room / walk in cooler unit outer and inner unit both of any make including cleaning the dust from body with blower cleaning of condensor and cooling coil, with castic soda, oiling to motor, cleaning of filter chekcing all electric connection all as speicified and directed by Engr-in-Charge. Note: Spare parts to be replaced shall me measured and paid seperately as supply only for the following items
Electronic circuit board for walk in cooler
Defrosting timer 40 Amps rating to walk in cooler
Solenoid valve for cold room
Outdoor unit fan motor as per sample
Evaporator fan motor with blade of cold room outdoor unit as per make and model on existing at site
M & L for replacing unserviceable door lock assembly of cold room existing as per site directed by Engr-in-Charge
S&F in replacement of bakelite connector block 30 Amps
S&F in replacement evaporater coil suitable for cold room of above size
S&F in replacement compressor suitable for cold room
M & L for dismantling of existing unserviceable following voltage stabilizer for repairs including replacement of relays, electronic voltage sensor circuits and meter, micro switch, indication light RC filters and other connected items for making functional as per the entire satisifcation of Engr-in-Charge and replace of unserviceable transformer and testing complete.
Up to 1 KVA
Up to 2 KVA
Up to 4 KVA
Up to 5 KVA
Disconnecting electrical /mechanically and lowering to the ground for repairing / over hauling the desert cooler including replacement of canvas grass/ wood wool pads and spray painting to body with one coats of anti corrisive red oxide primer for any make of desert cooler to make it fully functional including replacement of unserviceable / defective spare parts, transportation to and from, re-installation and testing on completion to the entire satisfaction of Engineer-in-Charge. Note: Spares to be replaced shall be measured and paid separately as supply only under respective item of this BOQ.
Supply only water lifting pump 1/70 HP capcity, operated on single phase 230 volts with all accessories and testing complete to the entire satisfaction of Engr-in-charge.
Supply only fan motor of desert cooler of any capacity including supporting legs, nuts and bolts etc.
supply only fan blade with bush for desert cooler motor
Supply only electronic control circuit board (PCB) as per existing type for desert cooler
Supply only swing motor for air cooler
S & F metal plug tops for 2 pin and earth socket AC box of capacity 240 V, 20 A all as specified and directed.
Supply only PVC Flexible pipe 25 - 30 mm dia as in drain pipe suitable for water cooler outlet including taking down old unserviceable pipe of any size
S & F incl connecting sheet metal encosure with two pin and earth plug and socket complete, with one double pole MCB 20 Amp 240 Volts AC. Make: L & T/Hager/Schnedier
S & F Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule for 15mm bore dia
S & F in push tap self closing taps of size 15 mm of cast iron or malleable cast iron, galvanised, screwed for iron pipe or for water cooler
Supply and fix PVC connecting pipe with brass nuts and washers at both ends of length not exceeding 60 cms for connection of water coolers with taking down old pipe
M & L for repair/ replacement to stainless steel waste water tray including welding, polishing, riveting, provision of fixing screws and refixing
M & L for Gaskets for top cover for water cooler of any capacity and make as per site requirement
Taking out unserviceable cooling coil of 165/285 Ltrs Refrigerator and S & F Cooling coil as per existing make and size all as specified and directred by Engr-in-Charge.
S&F in repairs damage condenser coil for refrigerator of capacity 210/300 Ltrs
S&F in repairs door switch for refrigerator of any type and any capacity
S&F in repairs pigmy lamp (indoor lamp) as per existing type for refrigerator
S&F in repairs freezer door as per existing make and type for refrigerator
S&F in repairs timer switch assembly for refrigerator as per existing for capacity 210 to 310 Ltrs
M & L for carry out routine maintenance, and servicing of package type air conditioner of capacity 7.5/5 TR including removing the dust from body with blower, cleaning the condenser and cooling coil, checking all the electrical and refrigeration piping connections, checking function of relay, capacitors, overload protector, thermostat, fan motor, blade, fan/blower drum, LT control panel, VFDs, electronic control box, etc, oiling/greasing of fan motor checking serviceability cleaning of the air filter woolen felt& refixing ensuring for air tighting complete repair and replacement of worn out/unserviceable spares including taking down and refixing, transportation to and from workshop if required and refixing it in its original place after fully servicing including testing & commissioning all as specified and directed by Engineer-in-charge. Note: 1 Spare parts to be replaced shall be measured & paid as supply only under relevant item of this Schedule (BOQ). 2. Gas required for testing and re-filling is deemed to be included in unit rate quoted.
Supply only relay HP & LP for package type AC plant of capacity 7.5 TR
Supply only condensor fan motor, 230 V, 50 Hz 920 rpm 1/3 HP for package type AC 7.5 TR, on exisiting make all as speicifed and directed by Engr-in-charge.
Supply only blower belt of package unit as per exisiting make and model with new one for 7.5 TR Air cooled package type AC plant
Supply only Intigrated circuit board with all electgronic components suitable for 7.5 TR capacity Voltas package type Air conditioner
Supply only SPPR circuit board suitable for 7.5 TR capacity package AC. Make : Voltas
Supply only 3 phase, 415 V, 50 Hz compressor of capacity 7.5 TR suitable for package type AC. Make: Voltas
Supply only fan blade suitable for outdoor unit of capcity 7.5 TR
Supply only Blower motor suitable for Voltas make Ductable type AC of capacity 7.5 TR
Supply only Electronic PCB kit for control panel suitable for Voltas make Package AC of capacity 7.5 TR
Supply & fixing in replacement including connection 3 pole AC power contactor, 32 Amps, 415 volt with auxilary contact 1 NO + 1 NC, having coil voltage 380 to 400 volts Make : Simens cat ref C4NE22 or equivalent make of L & T /Havells
leak testing & gas charging of package type air conditioner of capacity 7.5/5 TR including complete repair and replacement of worn out/unserviceable spares including taking down and refixing, transportation to and from workshop if required and refixing it in its original place after fully servicing including testing & commissioning all as specified and directed by Engineer-in-charge. Note: 1 Spare parts replaces shall be measured & paid under separte under relevant item of this BOQ as supply only. 2. Gas required for testing and re-filling including quoted rate.
Material and labour for shifting of split AC 1.5 TR & 2.0 TR with all accessoires and installed at new location, including fixing arrangement of indoor/outdor unit along with mounting bracket/Frame including cutting holes to wall and making good disturbed surfaces to match with the existing finish of walls etc complete all as shown and directed by Engr-in-charge. Note: Additonal copper tubing and gas charging as required to make existing AC serviceable at new location shall be measured and paid separately. All other items are deemed to be included in the unit rate quoted.
Supply only copper tubing 5/8" for 1.0/1.5/2.0 TR split AC with proper insulation of suitable size and taking out old one as per directed by Engr-in-Charge.
Supply only copper tubing 1/4" for 1.0/1.5/2.0 TR split AC with proper insulation of suitable size and taking out old one as per directed by Engr-in-Charge.
SKS Electricals
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .