Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹3.6 CrAccepted-AOC HOUSE NO 953 SECTOR 23 HUDA BHIWANI TEHSIL AND DISTRICT BHIWANI | BHIWANI | BHIWANI | HARYANA | ₹3.6 Cr | 1 | Accepted-AOC L-1 |
| 2 | 2₹3.9 Cr+₹30.5 L (8.54%)Rejected-AOC VPO JAGRAM BASS TEHSIL BADHRA DISTT CH DADRI 127308 | JAGRAM BASS | CHARKHI DADRI | HARYANA | 127308 | ₹3.9 Cr+₹30.5 L (8.54%) | 2 | Rejected-AOC L-2 |
| 3 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹3.9 Cr
EMD Value
₹7.7 L
Closing Date
22 Mar 2022, 2:00 pmClosed
Xen, LWS Division, Loharu
Xen, LWS Division, Loharu
Utilization of treated water from STP Loharu Distt. Bhiwani for the Irrigation purpose
2022_HRY_210702_15
2510/16A/A1-A20
Open Tender
Civil Works
Works
450 days
Loharu
Please refer Tender documents.
2 documents required · 2 mandatory
₹15,000
₹7.7 L
Yes
13 Jun 2022
17 Mar 2022
22 Mar 2022
17 Mar 2022
22 Mar 2022
17 Mar 2022
Amount
E/work excavating for tranches required width for pipeline exceeding 300mm dia (HSR 4.16.1.3)
E/work excavating for tranches required width for pipeline exceeding 80mm dia but not exceeding 300 mm dia (HSR 4.16.1.2)
Providing lowering, laying, fixing in position and jointing all level in tranches ISI Mark HDPE pipe of PE-80 315 mm dia (HSR No 21.96.5
Providing lowering, laying, fixing in position and jointing all level in tranches ISI Mark HDPE pipe of PE-80 200 mm dia (HSR No 21.96.1)
Providing lowering, laying, fixing in position and jointing all level in tranches ISI Mark HDPE pipe of PE-80 400 mm dia (HSR No 21.96.7)
Supply & installation of air release valve 50mm (HSR BASIC RATES B 1480)
Supply & installation HDPE Reducer
Supply & installation HDPE Tail Pice with flange
Supply & laying GI pipe 50 mm in 3.05 mtr length welding with flanges complete in all respect(HSR 20.54.1)
Supply & installation of butterfly valve (HSR No. EL 281)
(A)Supply & installation HDPE Sluice valve 400 mm dia HSR 20.10.8+20.4+20.50
(b)Supply & installation HDPE Sluice valve 315 mm dia HSR 20.10.6 +20.4+20.5
(c)Supply & installation HDPE Sluice valve 200 mm dia HSR 20.10.4+20.4+20.5
(a)Supply & jointing M.S. pipe 100 mm dia HSR EL 270
(b)Supply & jointing M.S. pipe 125mm dia HSR EL 269
(c)Supply & jointing M.S. pipe 250 mm dia HSR EL 266
(a)Supply & jointing M.S. flanges 250 mm dia HSR B 1542
(b)Supply & jointing M.S. flanges 100 mm dia HSR B 1539
(c)Supply & jointing M.S. flanges 125 mm dia HSR B 15420
CC 1:2:4 with stone aggregate 20mm nominal size HSR 6.14.2
1st class brick work 1: F&P HSR 7.20.1
Cement plaster 12mm thick in 1:4 HSR 11.5.3
Excavation in soil (any type) using hydraulic excavator CK90 with hydraulic excavator of 0.9 cum bucket capacity including cutting, trimming bottom and side slopes in accordance with requirment of lines grades and cross sections, including all lifts and combined load upto 30 mtr HSR 4.12.1
Earth filling under floor with surplus soil HSR 4.32
CC 1:3:6 with stone ballast or shingle HSR 6.14.2
Reinforced CC M-30 mechanically batch mixed using batch type concrete mixer as per IS 1791 and vibarted by needle vibrator but excluding HSR 6.24 & 6.26
Cold twisted Deformed Bars Fe 500 Garde as per IS 1786-2008, for RCC works where not inlucding in the complete rate of RC including bending and placing in position complete HSR 6.33.6
Centring and shuttering for faces of walls, partitions, retaining walls and the like (vertical or battering including attached pilasters HSR 6.29.2
Preparation of plastered for paiting using ready mixed cement based wall putty by applyng two coats to get required finish HSR 11.6
Applying priming coat with cement primer coat to give an even shade on newly plastered surface HSR 11.69.1
Distempering with Arcylic washable oil bound distemper two coats over one priming coat to give an even shade HSR 11.64.1
Finishing walls with exterior decorative cement based paint such as snowcem, robbiacem etc two coats to give an even shade HSR 11.93.1
Painting two coats on iron sheets with roofing ready mixed paint on new work to give an even shade HSR 11.73.1
Centering and shuttering for flat surface such as suspended floors, roofs landings chajjas shelves etc. HSR 6.30.4
Reinforced cement concreet M-20 with mechanically batch mixed using batch type concrete mixer as per IS:1791 but excluding steel reinforcement, centering and shuttering
Base course of floors consisting of 100 mm thick cement concrete 1:8:16 and 100 mm sand or stone filling
Wrought iron and mild steel(Using angles, flats, square bar, tee and channels) ladders, grills, grating frames, window guards, iron doors openable or fixed stairs case or parapet or any other type of railing, gates and tree guards etc, including cost of screws and welding rods or bolts and nuts complete fixed in position
Supply& installation of ISI Mark Monoblock Pump Set complete in all respect departmental
Digital water meter
Job Sign board , documentation, Audio Visual at different atages
(a)Deployment of 4 No. of person three shift for 1 year
(b)Electrication of pumping room
(c)Supply , installtion , commisstoning of solar system pumps & allied items as per Annex - 1
Training Programme for farmers
Farmer Exposure visit .
Job Crossing of Area, Road, Crop Compensation etc for laying of Irrigation pipeline LS
Consultancy of hydrant and pumping
THE JAGRAM BASS COOP L/C SOCIETY LTD.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .