Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.8 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹29.0 L+₹5.0 L (21.0%)Rejected-Finance 801802 SAKAR IV OPP MJ LIBERARY ELLISBRIDGE ASHRAM ROAD AHMEDABAD AHMEDABAD GUJARAT 380006 | 801802 | L2 | Rejected-Finance NOT BEING L1 | |
| 3 | L3₹33.1 L+₹9.1 L (38.2%)Rejected-Finance GROUND FLOOR SUIT NO 2 SARITA APARTMENT KHARIDA MAIN ROAD KHARAGPUR 721 301 DIST PASCHIM MIDNAPORE WEST BENGAL | KHARAGPUR | PASCHIM MIDNAPORE | WEST BENGAL | 721301 | L3 | Rejected-Finance NOT BEING L1 |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
18 Sept 2021, 6:00 pmClosed
Shri R Durga Shyam, EE
GE (AF) Kalaikunda PO Kalaikunda Air Field Dist Paschim Medinipore St West Bengal Pin 721303
REPAIRS AND MAINTENANCE OF FIRE ALARM SYSTEM AT AF STN KALALIKUNDA UNDER GE (AF) KALAIKUNDA.
2021_MES_456846_1
8685/E8
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
AF STN KALAIKUNDA
AS per Tender Documents
7 documents required · 7 mandatory
₹500
Yes
GE (AF) KALAIKUNDA
₹60,000
Yes
21 Oct 2021
3 Jul 2021
20 Sept 2021
3 Jul 2021
18 Sept 2021
17 Jul 2021
Amount
Comprenesive maintenance and repair including renewal/replacement and installation of defective parts of all existing fire detection system complete consisting of addressable fire control panel 19 Nos., Conventional Fire Alarm Panel 11 Nos., Remote Terminal Unit panels 20 Nos., smoke/heat detector, response indicator, sounder, Manual call Point, Amlifier 20 Nos, Loud speaker, Loop isolator, Zone monitor module, Modem etc. located in technical and domestic area , to make them 100 % serviceable incl checking of fire detector, checking the batteries and its connections, alarm system and its functions, functionallity of fire control panel and indicating eqpt all to be checked by the operation of trigger device in each zone as described. The system installed in Fire station and at other locations to be inspected and checked for its functionality and to make functional in all respect and if any defect observed to rectify it by visiting every month through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified and as directed Note:- (i) Cost of new components shall be paid separately under relevant items. (ii) Contractor's rep shall visit every month to check all fire panel and system to check its functionility and to make them functional. if any defect observed. (iii) He shall take the serviceability certificate duly signed by the user and submit to the department. After obtaining / producing seviceability certificate of system payment will be made to contractor . (iv) The Contractor shall provide the following comprehensive services arising out of wear and tear of the normal running includes maintenance of all mechanical, electrical and electronic parts /sub-assemblies. The preventive maintenance report will be as per the Original Equipment anufacturer's instructions and Specification. The Contractor may claim payment on monthly basis. (v) Breakdown Maintenance : The Authorised Service Engineer of OEM or OEM Certified Agencies will carry out all breakdown maintenance after receiving information (written or oral) from GE (AF kalaikunda) officials or their representatives, The OEM's authorised service representative or OEM certified agencies will carry out the required repairs of the units and appraise GE,Engineer-in-Charge and JE the status of the break down repair at site. No payment shall be made on account of any breakdown service during maintenence period
(a) Station Fire section
(c) Ration store
(d) MT FSS
(e) Logistics & Immols
(f) ATC Building
(g) Base Ops
(h) Hawk Tech Flt (Hawk Tech Hanger)
(j) Hawk Tech Flt FSS R1, R2, R3 (Hawk Tech Hanger)
(k) OCU 'B'
(l) OCU 'A'
(m) MT POL Store AF
(n) Logistics Aerolube Store
(o) CEO Complex
(p) BCR Buliding
(q) GPU & Logs POL (MT Section)
(r) HST & Compressor (MT Section)
(t) 17 END ABH (17 ORP Hut)
(u) 35 END ABH (35 ORP Hut)
(v) HQ Signal Section
(w) 771 SU Panel No.1
(x) 771 SU Panel No.2
(y) IT Cell Panel No.1
(z) IT Cell Panel No.2
(aa) PAR Building
(ab) MES MT POL store
(ac) Main power House
(ad) MES DG POL store
(ae) 33 MRS
Servicing of all multisensor detector with heat and smoke combination photoelectric after taking down from its position and refixing after servicing as per OEM instructions through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, checking and testing its functionality, tracing and clearing any fault observed including cleaning detectors through air blower on site complete all as specified and directed. Note : AS per periodicity of cleaning of detector to be done once in 11 Month or before as and when required basis).
Testing of flame dectors device, checking its functionality, rectifying any defects observed and testing them with UV and IR detection at site in hangers complete all as specified in OEM instructions through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE and directed by EIC. Make : CIMCON / AGNI Controls
Supply and fixing of GSM SIM card with validity of SMS packs for 12 months suitable for existing alarm control panels to pass the signals from fire alarm panels located in different sections to Main fire alarm panel located in Fire Brigade section through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE complete all as specified and directed by EIC. Note:- GSM service provider shall be choosen (as per network availability) by Engr-in-Charge.
Supply only of 12 V, 100 AH battery for back up to all FACP and RTU panel as per OEM specification complete. Make: Exide/Amar Raja.
Supply only of 12 V, 7 AH battery for back up to all FACP panel as per OEM specification complete. Make: Exide/Amar Raja.
Supply only Indoor type detectors complying with and type certified to EN-54 Addressable type multisensor detector with heat and smoke combination photoelectric /optical with base with self built intelligence as per OEM specification complete all as specified and as directed. MAKE- GST
Supply only electronically addressable intelligent resettable type manual call point with mounting base complying with EN 54 standard and LPCB approved with following specifications as under:- Power- 24V, ≤ 0.6 mA (Standby Current) ≤1.8mA (Alarm Current), Class A , Initiating Mode - Pressing the action plate manually, Resuming Mode-Manually Resumed by a special Key , Ingress Protection IP-43 & Material-ABS all as per IS : 2189 / 1988 as per OEM specification complete all as specified and as directed Make: GST/Morley/ Siemens/Bosch)
Supply only intelligent loop isolator with mounting base complying with EN 54 standard and LPCB approved with the specifications as appended below:- a) Power- 24V, ≤ 3 mA (Standby Current) ≤15mA (Action Current) b) Class A , c) Initiating Mode- Yellow flashes when polling, illuminates in action, d) Ingress Protection IP-30 & Material-ABS or as per OEM specification complete. Make: Make: GST/Morley/ Siemens/Bosch) or equivalent make
Supply only the announcing device Remote response indicator as per OEM specification complete all as specified and directed. Make: GST/Morley/ Siemens/Bosch)
Supply only fire alarm sounder/strobe electronic type horizontal single stage continous normal operation for atleast 20 minutes with sound level 65db to 120db measured at 1.5 m with sound output variation of +5db 500m range as per OEM specification complete and directed. Make: GST/Morley/ Siemens/Bosch)
Supply only Wireless modem suitable for GSM based communication system to be mounted in RTU enclosure shall be installed at all proposed buildings as per OEM specification all as specified and directed. Make: GST/Morley/ Siemens/Bosch/ CIMCON)
Supply only Amplifiers suitable 30 Watts, 230 VAC 50 Hz as per OEM specification complete all as specified and directed. Make: Ahuja.
Supply only indoor detector complying with and type certified to EN - 54 Addressable type flame dectors with Uv and IR detection capacity (add up cost of module to be a complete set, the type of module shall be relay type module) with self built intelligence as per IS : 11360 as per OEM specification complete all as specified and directed. MAKE-AGNI Controls or equivalent.
Supply only Input Module for Fault and Alarm Monitoring, 24VDC required (Zone Monitor Module) as per OEM specification complete.Make: GST/Morley/ Siemens/Bosch)
Supply only wall mounted horn type loudspeaker 15 watt 230V AC ,50Hz of sturdy design weather proof type re-entrant horn type loudspeaker for operating under rough conditions as per OEM specification complete. Make:- Ahuja/Morley/ Siemens/Bosch)
Supply only 24 V DC Power Supply Unit of iRTU,as per OEM specification complete Make : CIMCON//Morley/ Siemens/Bosch
Supply only 12/5 V DC Power Supply Unit of iRTU, as per OEM specification complete Make : CIMCON//Morley/ Siemens/Bosch
Supply only ARM7 based CPU card with 3 nos. serial Port, 1 ethernet Port and SD card slot of RTU as per OEM specification complete Make : CIMCON//Morley/ Siemens/Bosch
Supply only Analog and Digital I/O Card of RTU, as per OEM specification complete Make : CIMCON//Morley/ Siemens/Bosch
Supply only DI/AI Termination PCB of RTU,as per OEM specification complete Make : CIMCON//Morley/ Siemens/Bosch
Supply only Display and Keyboard of RTU,as per OEM specification complete Make : CIMCON//Morley/ Siemens/Bosch
Supply only DO Termination PCB of RTU, as per OEM specification complete Make : CIMCON//Morley/ Siemens/Bosch
Supply only MCB 6A SP, C curve , 10 KA as per OEM specification complete Make : Siemens / Bosch / L&T / Schneider.
Supply only LEDs (Red/Green) for RTU Panel.as per OEM specification complete Make : Safetek or equivalent make
Supply only Relay card : 8 relay 1 Change over for RTU panel as per OEM specification complete. Make :Connectwell / Brisk / Elmex.
Supply only Isolation transformer-300 VA for RTU panel as per OEM specification complete Make :Safetek or equivalent make
Supply only Push Button with NO/NC contact (BLACK) as per OEM specification complete Make: ESBEE or equivalent make
Supply only GST200-2 Main Board F2.908.826a for FACP as per OEM specification complete Make: GST or equivalent make
Supply only LCD Screen CGM12864 for FACP as per OEM specification complete Make: GST/Morley/ Siemens/Bosch or equivalent make
Supply only GST200 Rubber Keypad F7.843.249 for FACPas per OEM specification complete Make: GST/Morley/ Siemens/Bosch or equivalent make
Supply only GST200 Loop Interface Board F2.908.828 (RoHS) for FACP as per OEM specification complete Make: GST/Morley/ Siemens/Bosch or equivalent make
Supply only GST200 Power Supply Unit F2.932.069 (20100682) for FACP as per OEM specification complete Make: GST/Morley/ Siemens/Bosch or equivalent make
Supply only Transformer 220V/27V-100W-R for FACP as per OEM specification complete Make: GST/Morley/ Siemens/Bosch or equivalent make
Supply only Sine Wave Inverter Capacity : 850 VA UPS as per OEM specification complete Make: Luminous / Microtek.
Supply only copper conductor of size 1.5sqmm X 2 run FRLS flexible wire complete all as specified and directed.
Supply only Optical conventional smoke detector 300 series,LPCB as per OEM specification complete Make:-Agni / System Sensor / GST.
Supply only RoR conventional Thermal detector 300 series,LPCB as per OEM specification complete Make:-Agni / System Sensor / GST.
Supply only two wire Plug in detector base series 300 LPCB as per OEM specification complete Make:-Agni / System Sensor / GST.
Supply only conventional MCP ,Red colour with LED 470 ohms, with back box and surface mouting box red colour as per OEM specification complete Make:-Agni / System Sensor / GST.
Supply only conventional Horn cum strobe, wall mounted,red colour as per OEM specification complete, Make :- Honywell / Agni / System Sensor.
Supply only conventional Remote response indicator ABS body with dual LED as per OEM specification complete Make :- Honywell / Agni / System Sensor.
Supply only step down transformer for convention fire alarm panel as per OEM specification complete of Make Agni or equivalent make (as per existing).
Supply only two zone Interface card for fire panel of as per OEM specification complete make Agni or equivalent make
Supply only Display card for fire panel of as per OEM specification complete make Agni or equivalent make
Supply only Main Board (CPU) for fire panel as per OEM specification complete of make Agni or equivalent make
Supply only Transistor with heat sink for fire panel as per OEM specification complete of make Agni or equivalent make
Supply only 2 Zone conventional Fire Alarm Panel as per OEM specification complete Make: Agni/GST/Honeywell.
Supply only GSM Auto dialer as per OEM specification complete Make: SECSDE or equivalent.
Supply only Addressable Fire alarm Control Panel with 2 Loopas per OEM specification complete Make: GST.
M&L for Repair and maintenance of HFC gas based fire fighting, suppression and extinguisher system with sprinkler of Make SIEMENS SINORIX (gas based fire suppression system for power and signal equipment) , maintaince of Fire alarm Panel with Gas release module and battery back up of Make AGNI, Model Delta, Ver 2.1 & ASES, checking all circuits to make it functional,checking and refilling of Nitogen pressurized HFC 227 ea extinguisher HFC gas in cylinder of Make Siemens, checking and making valves functional, checking of pressure gauge, low pressure supervisory switch , electromagnetic actuator, Pheumatic actuator, safty valves and controls, flexible discharge hose, and flexible Pneumatic hose, manual Pneumatic actutator, sinorix check valve, on line standby system, nozzels, Manual abort switch, its functionality and seviceability of operation of release valve of cyclinder from control panel and extinguishant relase MCP box, including checking of circuits, carrying necessary repairs, cleaning of gas sprinklers/ nozzles complete to recommissioning of complete gas extinguisher system and make it functiona including replacement of unservicible and defective parts all as specified and directed by Engr - in - Charge. Note :- (i) Cost of Gas and valve of cylinder shall be paid separately under relevant items. (ii) HFC gas exhinguisher system located at two location i, e in Signal section in technical and domestic area.
Supply and refilling of HFC 227 Gas UL approved in cylinder of capacity of water capacity 120 ltrs each and 67.5 ltrs each including transportation charges of cylinder to filling stn complete all as specified and directed by Engr-in-Charge. Note : Contractor has to submit the purchase voucher and test certificate of gas and cylinder.
Supply and installation of check valve of Siemens sinorix 227 cylinder of Nitrogen pressurized HFC 227 ea HFC gas suppression gas fire extinguisher system of capacity 120 Ltr and 67.5 ltr as per OEM specification complete all as specified and directed by Engr-in-Charge.
Supply and installation of extinguisher release manual abort switch of Make ASES HFC gas fire suppression system as per OEM specification complete complete all as specified and directed by Engr-in-Charge.
Supply and installation of ABC type stored pressure type fire extinguishers 6Kg capacity with Monoammonium Phosphate complete with squeeze grip type valve, discharge hose & mounting bracket as per OEM specification complete
CIMCON SOFTWARE INDIA PVT. LTD.
Lotas Engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .