| 1 | L1₹24.9 LAccepted-AOC NEAR CENTRAL SCHOOL BALASORE DIST BALASORE ORISSA 756 001 | BALASORE | BALASORE | ORISSA | 756001 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹25.8 L+₹79,184.80 (3.16%)Rejected-Finance BANK COLONY MATHASAHI MOTIGANJ BALASORE BALASORE ODISHA 756003 | BALESHWAR | ODISHA | 756003 | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹26.0 L+₹97,235.92 (3.89%)Rejected-Finance | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹27.9 L+₹2.9 L (11.7%)Rejected-Finance PASCHIM BHAGABANPORE DARUA CONTAI PURBA MEDINIPUR 721401 | PURBA MEDINIPUR | PURBA MEDINIPUR | WEST BENGAL | 721401 | L4 | Rejected-Finance Not being lowest | |
| 5 | L5₹28.4 L+₹3.4 L (13.5%)Rejected-Finance | L5 | Rejected-Finance Not being lowest |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
21 Aug 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER
GE I R and D Chandipur Post Chandipur PIN 756025
REPAIR REPLACEMENT AND CLEANING OF SEWAGE LINE GULLY TRAP SEPTIC TANK SOAK WELL MAN HOLE OVER HEAD TANK AT BALASORE
2023_MES_610443_1
8863/CDP
Open Tender
Civil Works
Item Rate
270 days
Balasore
As per Tender Documents
8 documents required · 8 mandatory
₹500
GE I R AND D Chandipur
₹50,000
Yes
6 Oct 2023
24 Jul 2023
23 Aug 2023
24 Jul 2023
21 Aug 2023
7 Aug 2023
Amount
NOTE (Applicable for all items) :- The bidders/contractors are advised to read tender document & all corrigendum / amendments and General conditions of contracts before entrying/quoting the rates.
Removing carefully the precast cover slabs of septic tanks and Dewatering/ desludging and taking out deposited sludge silt residue of both organic and inorganic nature, mechanically with sewer suction cum jetting Machine mounted on Truck, cleaning the septic tank / Soakage well by removing solid waste/sludge from the tank removing the sludge from the edge of septic tank after drying and removing the same outside MD land and land where directed including applying one coat of linseed oil on the bottom and sides of the septic tanks (inner side) and setting the same covers in old position in CM 1:6 after inspection by Engr-in-Charge and as directed for Septic Tank of size 13.60mx4.0mx6.0m in LBH (PXE SEPTIC TANK) Note: work will be executed in foul condition
All as per Sl Item No. 1 here-in-before but for Septic Tank of size 14mx4.6mx3.0m in LBH (PXE SEPTIC TANK)
All as per Sl Item No. 1 here-in-before but for Septic Tank of size 6.0mdia x 3.60m Depth (ITR Circular SEPTIC TANK)
All as per Sl Item No. 1 here-in-before but for Septic Tank of size 13.60mx4.0mx6.0m in LBH (ITR SEPTIC TANK)
All as per Sl Item No. 1 here-in-before but for Septic Tank of size 2.5mx2.5mx2.5m in LBH (OT Road SEPTIC TANK)
All as per Sl Item No. 1 here-in-before but for Septic Tank of size 4.5mx2.0mx2.5m in LBH (OT Road SEPTIC TANK)
All as per Sl Item No. 1 here-in-before but for Septic Tank of size 3.00mx2.0mx2.5m in LBH (Septic Tank near ROMI mess)
All as per Sl Item No. 1 here-in-before but for Septic Tank of size 13.60mx4.0mx6.0m in LBH (Septic Tank near ROMI mess)
All as per Sl Item No. 1 here-in-before but for Septic Tank of size 7.0mx4.0mx3.0m in LBH (T-16)
All as per Sl Item No. 1 here-in-before but for Septic Tank of size 13.60mx4.0mx6.0m in LBH (Septic Tank near ROMI mess)
All as per Sl Item No. 1 here-in-before but for Septic Tank of size 7.0mx4.0mx3.0m in LBH ( T-16)
All as per Sl Item No. 1 here-in-before but for Septic Tank of size 2.5mx1.5mx2.5m in LBH (Septic Tank PH colony)
All as per Sl Item No. 1 here-in-before but for Septic Tank for 50 users (P-83, T-12, 11, 39, 78 and PH no-5)
Removing carefully the cover slabs of manholes of any size and shape and removing the scum/sludge including any organic or inorganic matters and disposing the same to a distance exc 250m and n.exc 500m where directed and setting the manhole cover old in position in CM 1:6 after inspection by Engr-in-Charge and as directed.
Cleaning carefully 100mm dia pipe with using fresh water for the blockage in CI or SWG pipe of the following sizes in between man holes using mechanically oprated Hydraulic pressure machine equpied with jet and suction pressure cleaning and passing rubber ball through line to ensure all blockage perfectly clear complete all as directed.
All as per Sl Item No 15 above but 150mm dia pipe complete all as directed.
Cleaning of blockage in the floor/nahni traps in kitchen or bath room or sinks by manually or with water jet after carefully removing the old gratingw and refixing the grating in the same position including finishing with white cement complete all as specified and as directed by Engr-in Charge.
Removal carefully the precast cover slab of drain, Cleaning and removing of silts from drain and hume pipe of any description by roding and well flushing with water, taking out west materials and disposing the same to a distance not exc 50m and setting the same cover in old position complete all as directed by Engr-in-Charge.
Removing carefully the cover slabs of gully traps of any size and shape and removing the scum/sludge including any organic or inorganic matter to a distance exc 250m and n exc 500m and setting the civer slab in old position in CM 1:6 after inspection by Engineer-in-Charge and as directed.
M & L for removing the plant from walls & roof of the building with complete roots, applying recommended chemicals to prevent further growth as directed, making good the disturbed surface with CM 1:3 and applying surface finishs to match the existing surface including removal of debris etc outside the premises complete all as required and specified.
M&L cleaning of the service tanks of capacity upto 500 liters twice (as directed) installed on roofs and 2nd, 3rd, or 4th stories of building at various places by emptying the tanks, by removing the scale and other all other foreign materials deposited on side wall and bottom of the tanks by scraping and brushing with wire brush and cleaning with bleaching powder slurry and allowed to dry and tajk washing and cleaning the tank with fresh water including refixing the top cover of tank properly after cleaning and writing letters such as details of the tanks like date of cleaning, capacity of tank with synthetic enamel paint with letter size 10cm heigh in block colour, over a thick of size 60x 30mm complete all as directed by Engr-in-Charge.
All as per Sl Item No. 21 above but service tanks of capacity above 500 liters and upto 1000 liters.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundations, etc. or manholes, sewage lines, etc. n exc 10 sqm on plan and getting out in soft / loose soil.
Removing surplus excavated spoil/earth to a distance not exc.50M and deposited where directed at a level not exc.1.5 M above the starting point.
Returning filling in soft /loose excavated soil including spreading leveling watering and well ramming in layers not exceeding 25 CM and all as specified and directed.
Demolition and breaking up of drain pipes of 100 mm dia (Salt glazed ware, AC or RCC) set in cement motar complete all as directed by Engr-in-Charge
Demolition and breaking up of drain pipes of 150 mm dia (Salt glazed ware, AC or RCC) set in cement motar complete all as directed.
S&F 100mm dia HDPE double wall corrugated SN 8 underground drainage/sewer pipes, confirming to IS 7328, single socketed in any length jointed with solvent cement laid in trenches or floors etc complete all as specified and as directed .
All as per Sl Item No 28 above but 150mm dia pipe complete all as directed by Engineer-in-charge.
M&L for 100mm dia pipes concrete bed to drain pipe including packing under and haunching against sides of pipes after they are laid and tested in PCC 1:3:6, type C-2, using 40mm graded stone aggregate all as specified.
All as per Sl Item No. 30 above but 150mm dia complete all as directed by Engineer-in-charge.
Cleaning of blockage in the WC "P" traps in toilet up to 1st Manholes by manually or with water jet after carefully removing the connected Caps of pipe and refixing the same in the position complete all as specified and as directed by Engr-in-Charge.
Demolition of brick wall built in cement mortar.
M/L brick work with flyash bricks old size straight or curved on plan to any radius exc 6m mean radius build in CM 1:4
All as per Sl Item No. 34 above but except bricks (using old size bricks obtained from item No - 33)
Taking down cement plaster on brick work or stone walls, etc including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified.
M&L Rendering 15 mm thick in cm (1:4) on brick wall, finished even and smooth (with out using extra cement ), all as specified and directed.
Supply only liquid water proofing compound (ISI marked) of approved make.
M & L for Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Demolition of reinforced cement concrete of any description and in any position as in ground floors all as directed by Engr-in-Charge
M & L for TMT bars (Fe 500D)10 mm dia and over cut to length, bent to shape required including cranking, bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as directed.
M & L for TMT bars (Fe 500D) 6 to 8 mm dia and over cut to length, bent to shape required including cranking, bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as directed.
M&L precast RCC(1:2:4) B-1 using 20mm graded aggragate as cover slab set in cement mortar 1:6 complete all as specified.
Taking down eaves rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and acessories)
Supply and Fix in repairs 75mm bore PVC (SWR) pipes for rain water pipes single socketed in any length with rubber ring joints fixed to walls including neccesay clamp brackets complete all as specified and as directed.
Supply and Fix in repairs 110mm bore PVC (SWR) pipes for rain water pipes single socketed in any length with rubber ring joints fixed to walls including neccesay clamp brackets complete all as specified and as directed.
Supply and fix in repair 110mm bore PVC (SWR) junction single (Single "T") equal or unequal with access door complete all as specified and as directed.
Supply and fix in repair 110mm bore PVC (SWR) bends of any radius complete all as specified and as directed.
Supply and fix in repair 75mm bore PVC (SWR) junction single (Single "T") equal or unequal with access door complete all as specified and as directed.
Supply and fix in repair 75mm bore PVC (SWR) bends of any radius complete all as specified and as directed.
S & F in repair PVC (SWR) vent cowl of 75mm complete all as directed by Engineer-In-Charge.
S & F in repair PVC (SWR) vent cowl of 110mm complete all as directed by Engineer-In-Charge.
S/F in repair PVC ball valves high pressure with polythene float and fly nut complete, screwed for iron pipe of 20mm bore complete all as specified.
S/F in repair PVC ball valves high pressure with polythene float and fly nut complete, screwed for iron pipe of 25mm bore complete all as specified .
M & L in repair for PVC (SWR) gully trap 125/110 mm,setting and jointing with solvent cement complete all as specified.
S&F in repair PVC (SWR) multi floor trap 75 mm diawith grating including jointing with solvent cement complete all as specified.
Demolition of cement concrete(unreinforced) of any description and in any position not otherwise specifically provided.
M&L providing PCC(1:3:6) type C2 using 40mm graded aggregate as in foundation, filling and mass concrete complete all as specified.
M & L for Plain Cement Concrete Type B1 1:2:4 (using 20 mm graded stone aggregate) as in copings, bed plates etc, including necessary form work complete all as specified.
M&L for PCC 1:2:4 type B1 using 20mm graded stone aggregate as in surface channel or drains complete all as specified.
M&L for extra forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/stopped ends etc.
Add or deduct for each 25mm girth or part thereof over or under 30 cm ditto.
M&L 75mm thick, cement concrete, type C-1, 1:3:6 (20 mm graded aggregate) finished the surface even and smooth without using extra cement complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises.
M&L rendering 10 mm thick cement plaster in CM 1:4 on fair faces of brick work for fixing of wall tiling complete all as specified and directed.
M&L for 15 mm thick screed bed or bedding layer of mortar in CM 1:6 for laying floor finishes for non skid ceramic and grinaite tiles complete all as specified and directed.
M&L Glazed ceramic coloured tiles 450mm x 300mm x 7mm thick set coloured tiles as in dado, skirting and vertical surfaces set and jointed in neat cement slurry and pointed in white or coloured cement to match with tiles complete all as specified and directed.
M&L Non Skid coloured ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.06 sqm but not exc 0.11 sqm in floors etc set & jointed in neat cement slurry and pointed in coloured cement complete all as specified and directed.
S&F in repairs 10 Liters capacity, low level flusing cistern, PVC, white, with inlet ball valve, float, handle, flush pipe of polyethylene of low or high density of PVC, 32mm dia including brackets and connections to pipe complete all as specified and as directed.
S&F in repairs wash down water closet (EWC) complete white with plastic water closet seat black closed pattern with flat bottom anc cover and mild steel chromium plated or aluminised hinging device and flush pipe of polythelene of low or density or PVC 32mm dia for low level flushing cistern complete all as specified and directed.
S&F in repairs Vitreous china Squatting pan Orissa pattern of size 580mx440mm wite with integral foot rests (excluding flushing cistern and flush pipe) complete including concrete bedding complete all as specified and directed.
M&L for rendering 10mm thick in cement mortar 1:4 on internal wall brick / concrete surfaces, finished even and smooth without using extra cement
M & L for applying evenly a priming/tack coat with bituminous primer at 10 Kg per 10 Sq.m complete all as specified.
M & L for Sand filling under sunken floors or in foundations including watering and consolidation all as specified and directed.
M&L for PCC 1:5:10 Type E-2, using 40mm graded aggregate as in filling in Sunken floor complete all as specified and as directed.
M&L for 30mm thick PCC 1:2:4, type B-0, using 12.5mm graded aggregate as in sunken floor flooring complete all as specified and as directed.
M/SNeelachal Enterprises
ALLIANCE
RANA ENTERPRISES
jlenterprise
Bidder Name
RANA ENTERPRISES
ALLIANCE
M/S T.N.CONSTRUCTION
M/SNeelachal Enterprises
jlenterprise
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .