| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.0 LAccepted-AOC | L1 | Accepted-AOC AWARD OF CONTRACT | |
| 2 | L2₹35.3 L+₹1.3 L (3.94%)Rejected-Finance NO 14 M C RAJA STREET MITTANAMALLI I A F AVADI CHENNAI 600 055 | CHENNAI | CHENNAI | TAMIL NADU | 600055 | L2 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 3 | L3₹37.3 L+₹3.3 L (9.74%)Rejected-Finance NO 17 5 SOLOMON STREET ADHI NAGAR EAST TAMBARAM CHENNAI 600 059 | CHENNAI | TAMIL NADU | 600001 | L3 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 4 | L4₹38.7 L+₹4.8 L (14.0%)Rejected-Finance 30 20 ATHIPALAYAM ROAD CHINNAVEDAM PATTI POST COIMBATORE 641 006 TN | COIMBATORE | COIMBATORE | TAMIL NADU | 641006 | L4 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 5 | L5₹39.2 L+₹5.3 L (15.6%)Rejected-Finance 16 176 A BHARATHI PURAM NAGAI NAGAR DINDUGUL 3 | DINDUGUL | DINDIGUL | TAMIL NADU | L5 | Rejected-Finance BEING NOT LOWEST TENDER |
Tender Value
Refer Docs
EMD Value
₹97,560
Closing Date
28 Jun 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) SULUR
Garrison Engineer AF Sulur Military Engineer Services Kangayampalayam Post Sulur Coimbatore 641 401
PERIODICAL SERVICES TO SMQs, OMQs AND OTM ACCN IN DOMESTIC AREA AT AFS SULUR
2024_MES_658469_1
8654/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
GE (AF) SULUR
Please refer Tender documents.
9 documents required · 9 mandatory
₹0
₹97,560
Yes
3 Sept 2024
7 Jun 2024
1 Jul 2024
7 Jun 2024
28 Jun 2024
22 Jun 2024
7 Jun 2024 - 18 Jun 2024
Amount
SCHEDULE A BOQ
M&L preparation of old external/Internal wall surfaces,affected with seepage by applying acrylic elastomeric exterior waterproofing coating, liquid base,applied highly durable waterproof coating system with high quality acrylic emulsion, functional filler, sunlight stable pigment and quality fungicides to have seepage free wall complete all as specified and as directed.
Note for Item No 2:- (i) The above treatment shall have properties that provide features like crack bridging ability, breathability, flexibility & exterior durability and resists micro-organism growth.
(ii) The above treatment shall cover hairline cracks up to 0.5 mm effectively and shall have excellent crack bridging ability and shall bridge cracks up to 2 mm width.
(iii) The elongation at break is approx. 200 %. The tensile strength is 0.72 Mpa. and has a hardness shore ‘A’ scale of 72, with an adhesion strength of 1.5 Mpa.
(iv) The coating is UV resistant, algae and fungus resistant, and a crack bridging ability of 1-2 mm and the coating must be applied with temperature above 5°C and below 45°C.
(v) The coating shall be applied in two coats of by roller or brush application at the interval of 4-6 hours.Allow applied coating to dry or cure for 7 days.
(vi) Make of acrylic waterproofing coating:- STP Limited or Equivalent in M/s Sika India Pvt Ltd, M/s Fosroc Chemicals, M/s Thermex .
M&L for complete removal of existing dampness area and applying 1 mm thick wall care putty with two coats of oil emulsion distemper over three coats of smart care hydraulic pre fully weather proof coat complete all as specified and directed.
M&L repairs to cracks of any description,less than 5mm size by opening up cracks in V-groove manner approximately 6mm x 6mm size using mechanical cutter,cleaning the groove properly to remove loose particles, dust etc, sprinkling with clean water and filling with single component entitious crack filler using readymix powder of cementitious ingredients having compressive strength of 14 N/ mm² after 7 days of Make M/s STP Limited, M/s Sika India Pvt Ltd, M/s Fosroc Chemicals, M/s Thermex complete all as specified and as directed.
M & L for complete removal of existing painted old wood or wooden surface of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed
M & L for complete removal of existing painted old steel surfaces of any description exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
Note for item No 11 & 12 :- (a) The synthetic enamel paint shall be of 1st quality manufactured by the standard firms of make as specified.
(b) The contractor shall inform the GE, within three weeks of the acceptance of the tender, the brand/names of the manufacturers of paint proposed to be used in the works and submit samples thereof and obtain prior written approval of GE before their use in works.
(c) The contractor shall when so required by the GE, produce certificate from the manufacturer or their representative to establish that the brands of paints purchased by the contractor from them, satisfy the requirements of the relevant Indian Standards. Tint of paint, will be approved by the GE.
(d) Paints shall be obtained direct from approved manufacturer or from their authorized agents only of respective brands mentioned below and brought to site in sealed containers. The paint so procured shall be of first quality of any approved make as per list of makes specified. i. Berger Paints (Luxol), ii. Jenson & Nicholson (Brolac), iii. Shalimar Paints(Superlac), iv. Goodlass Nerolac (Nerolac), v. Asian Paints(Apcolite)
(e ) Unless otherwise specified the tints of paint shall be as approved by the GE
(f) The contractor shall submit samples of the paints proposed for the work along with results of tests conducted in approved laboratory as directed by the Engineer-in-Charge for approval.
(g) The surface shall be thoroughly cleaned and dusted. All dirt scales oil and grease shall be thoroughly removed before painting is started. The prepared surface shall be inspected and approved by the GE before painting is commenced. The weather shall not be foggy/rainy, dusty or windy. The suitability of the weather will be determined by the Engineer-in-Charge.
(h) No hair marks from the brush or clogging of paint buddles shall be left on the work. Surface shall ordinarily not be painted until it has dried up completely. Trial patches of paint shall be laid at intervals to check if drying is satisfactory.
M&L Hacking out old broken glass (any thickness, size, quality or description) from wooden frames/steel frames glazed with putty or fixed with beads and material and labour for 4mm plain sheet glass ordinary quality and glazed with oil putty or fixed with fillets 2nd class hard wood of sectional area not exc 3 Sqcm and glass not exc 0.5 sqm each pane complete all as specified and directed.
M&L preparation of old surfaces and applying reflective paint for Writing letters or figures (Block,Roman,Italic or Indian) n. exc 30 CM high complete all as specified and as directed.
M & L repair to ends of chajjas/ parapets by removing old concrete, loose material ,& cleaning of the reinforcement and finishing the surface in cement mortar 1:3 mixed with WPC as sper manufacturer instructions, finished fair & even and making good with existing finishes all as specified and directed. Rate quoted by the tenderer shall be deemed to inclusive of water proofing compound.
Note for item No 23 :- (a) The subject work is require to be executed in a bldg having height upto 12.50 mtr from natural ground level. Providing, fixing and erecting scaffolding in double face structure, as required along with approach system for the repairs / plastering of the buildings to facilitate execution of all items of works,complete with necessary support, propping system etc for external repair. The unit rate is deemed to be included this provision also.
(b) The unit quoted rated deemed to included for removing plant/ up rooting of vegetation growth including roots on wall/ roof/ parapet near pipe etc.
(c) The unit quoted rate deemed to be included for necessary safety equipments such as safety belt, ropes, helmets, netting etc mandatorily to be provided to labour working at height exceeding 3 mtr.
supply only integral water proofing compound complete all as specified and directed.
M&L Preparation of old plastered surfaces ceiling and applying two coat of white washing on ceiling surfaces complete all as specified and directed.
Note for item No 28 -: (i) The lime shall be slaked at site and shall be mixed and stirred with about five liters of water for 1 kg of unslaked lime to make a thin cream. This shall be allowed to stand for a period of 24 hours and shall then be screened through clean coarse cloth. 1 kg of gum dissolved in hot water shall be added to every one cubic meter of lime cream. About 1.3 Kg of sodium chloride dissolved in hot water shall also be added for every 10 kg of lime for making the coating hard and rub resistant. Small quantity of ultramarine blue (upto 3 gm per kg of lime) shall also be added to the last two coats of white wash solution and the whole solution shall be stirred thoroughly before use
(ii) Application of Whitewash:- Whitewash shall be applied with ‘MOONJ’ brush or other brush to the specified number of coats. The operation for each coat shall consist of a stroke of the brush given from the top downwards, another from the bottom upwards over the first stroke and similarly one stroke horizontally from the right and another from the left before it dries. Each coat shall be allowed to dry before the next coat is applied. No portion of the surface shall be left out initially to be patched up later on. The brush shall be dipped in whitewash, pressed lightly against the wall of the container and then applied by lightly pressing against the surface with full swing of hand
(iii)Whitewashing on ceiling should be done prior to that on walls.
M&L Preparation of new plastered surfaces wall Applying two coats of cement based paint over and including a coat of primer, of any description, complete all as specified and directed.
Note for Item No 32:- (i)Before applying cement based paint ,the surface shall be thouroughly wetted to control surface suction. The surface shall be moist but not dripping wet when the paint applied .Surfaces which readily absorb moisture shall be wetted in one operation not more than one hour before painting.Surfaces which absorb moisture slowly shall be wtted in at least two operations not less than 30 minutes apart.
(ii)To maintain a uniform mixture and to prevent segregation ,the paint shall be stirred frequently in the bucket.
(iii)Painting surfaces shall be cured as soon as paint has hardened so as not be to damaged by the spray about 12 hours after the applications.
(iv) Cost of scaffolding required deemed to be included in the quoted rate of item and nothing extra shall be admissible on this account.
(v)Paints shall be obtained direct from approved manufacturer or from their authorized agents only and brought to site in sealed containers. The paint so procured shall be of any approved make as per list of makes specified.
M&L preperation of new plastered surfaces of wall and applying two coats of OBD over one coat of alkali resistant primer complete all as specified and directed.
M&L for complete removal of existing treatment of old plastered surfaces wall applying two coats of OBD over a coat of alkali resistant primer complete all as specified and directed.
Note for item No 38 & 39:- (i): surface shall be thoroughly cleaned by mechanical means and approval shall be taken from engg in charge before application of alkali resistant primer.
(ii) . Not less than 24 hours shall be allowed between two coats and the second or subsequent coat shall not be started until the preceding coat has become sufficiently hard to resist marking by the brush being used. In hot dry weather the preceding coat shall be slightly moistened before applying the subsequent coat.
(iii)Paints shall be obtained direct from approved manufacturer or from their authorized agents only and brought to site in sealed containers. The paint so procured shall be of any approved make as per list of makes specified.
M&L Taking down cement plaster on brick or stone walls, or concrete or ceilings etc., including raking out joints, hacking for key, scrubbing down with water, etc., including removal of rubbish off the premises, removal and depositing serviceable materials where directed.
M&L rendering 15 mm thick in two layers on brick or stone or concrete surfaces,first coat 10mm thick in cement mortar 1:4 and 2nd coat 5mm thick in cement mortar 1:4 mixed with water proofing compound as per manufacturer instructions finished even and smooth without using extra cement complete all as specified and directed.
M&L Rendering 15 mm thick in cement mortar 1:6 mixed with water proofing compound as per manufacturer instructions finished even and smooth without using extra cement complete all as specified and directed.
Note for Item No 44 & 45 :- (a) Water proofing compound shall be measured and paid seperately.
(b) The unit rate quoted is deemed to include for removal of accumulated earth of any width and depth upto 15 cm cleaning/cutting the grass with hand operated petrol/kerosene driven grass cutting machine and removing the grass waste around 3 m from plinth protection to outside MD land.
(c ) Cost of scaffolding required deemed to be included in the quoted rate of item and nothing extra shall be admissible on this account.
M & L preparation of old decorated plastered or unplastered surface of wall, chajja, balcony, facia etc., brooming down or steel wire brushing down smoke soot, moulds mass, efflorescent, trading, oil, greasy spots and applying one coat of white wash complete all as specified and directed.
Note for item No 49 :- (i) The lime shall be slaked at site and shall be mixed and stirred with about five liters of water for 1 kg of unslaked lime to make a thin cream. This shall be allowed to stand for a period of 24 hours and shall then be screened through clean coarse cloth. 1 kg of gum dissolved in hot water shall be added to every one cubic meter of lime cream. About 1.3 Kg of sodium chloride dissolved in hot water shall also be added for every 10 kg of lime for making the coating hard and rub resistant. Small quantity of ultramarine blue (upto 3 gm per kg of lime) shall also be added to the last two coats of white wash solution and the whole solution shall be stirred thoroughly before use
(ii) Application of Whitewash:- White wash shall be applied with ‘MOONJ’ brush or other brush to the specified number of coats. The operation for each coat shall consist of a stroke of the brush given from the top downwards, another from the bottom upwards over the first stroke and similarly one stroke horizontally from the right and another from the left before it dries. Each coat shall be allowed to dry before the next coat is applied. No portion of the surface shall be left out initially to be patched up later on. The brush shall be dipped in whitewash, pressed lightly against the wall of the container and then applied by lightly pressing against the surface with full swing of hand
(iii)Whitewashing on ceiling should be done prior to that on walls.
M & L preparation of old plastered or unplastered surface of wall/ ceiling brooming down or steel wire brushing down smoke soot, moulds mass, efflorescent , trading, oil, greasy spotsand applying one coat of colour wash complete all as specified and directed.
Note for Item No 53 :- Colour wash shall be applied with ‘MOONJ’ brush or other brush to the specified number of coats. The operation for each coat shall consist of a stroke of the brush given from the top downwards, another from the bottom upwards over the first stroke and similarly one stroke horizontally from the right and another from the left before it dries.
M&L Preparation of plastered or un plastered old surfaces of walls, Chajja, balcony, facia etc. by brooming down or steel wire brushing scrapping down, smoke shoots moulds, mass efforescent salt, treating oil and greasy spots etc and applying one coat of cement based paint complete all as specified and directed.
Note for Item No 55 :- (i)Before applying cement based paint ,the surface shall be thouroughly wetted to control surface suction. The surface shall be moist but not dripping wet when the paint applied .Surfaces which readily absorb moisture shall be wetted in one operation not more than one hour before painting.Surfaces which absorb moisture slowly shall be wtted in at least two operations not less than 30 minutes apart.
(ii)To maintain a uniform mixture and to prevent segregation ,the paint shall be stirred frequently in the bucket.
(iii)Painting surfaces shall be cured as soon as paint has hardened so as not be to damaged by the spray about 12 hours after the applications.
(iv) Cost of scaffolding required deemed to be included in the quoted rate of item and nothing extra shall be admissible on this account.
(v)Paints shall be obtained direct from approved manufacturer or from their authorized agents only and brought to site in sealed containers. The paint so procured shall be of any approved make as per list of makes specified.
M&L Complete removal of existing plastering surface in walls, Chajja, balcony, facia etc. by brooming down or steel wire brushing scrapping down, smoke shoots moulds, mass efforescent salt, treating oil and greasy spots etc and applying two coat of cement based paint complete all as specified and directed.
Note for Item No 61 :- (i)Before applying cement based paint ,the surface shall be thouroughly wetted to control surface suction. The surface shall be moist but not dripping wet when the paint applied .Surfaces which readily absorb moisture shall be wetted in one operation not more than one hour before painting.Surfaces which absorb moisture slowly shall be wtted in at least two operations not less than 30 minutes apart.
(ii)To maintain a uniform mixture and to prevent segregation ,the paint shall be stirred frequently in the bucket.
(iii)Painting surfaces shall be cured as soon as paint has hardened so as not be to damaged by the spray about 12 hours after the applications.
(iv) Cost of scaffolding required deemed to be included in the quoted rate of item and nothing extra shall be admissible on this account.
(v)Paints shall be obtained direct from approved manufacturer or from their authorized agents only and brought to site in sealed containers. The paint so procured shall be of any approved make as per list of makes specified.
M & L preparation of old plastered surfaces of wall by using pressure washer, removal all dirt and dust and applying one coat of exterior emulsion weather proof paint complete all as specified and as directed.
Note for item No 67:- (a) The Exterior emulsion paint shall be of 1st quality manufactured by the standard firms of make as specified.
(b) The contractor shall inform the GE, within three weeks of the acceptance of the tender, the brand/names of the manufacturers of paint proposed to be used in the works and submit samples thereof and obtain prior written approval of GE before their use in works.
(c) The contractor shall when so required by the GE, produce certificate from the manufacturer or their representative to establish that the brands of paints purchased by the contractor from them, satisfy the requirements of the relevant Indian Standards. Tint of paint, will be approved by the GE.
(d) Paints shall be obtained direct from approved manufacturer or from their authorized agents only of respective brands and brought to site in sealed containers. The paint so procured shall be of first quality
(e ) Unless otherwise specified the tints of paint shall be as approved by the GE
(f) The contractor shall submit samples of the paints proposed for the work along with results of tests conducted in approved laboratory as directed by the Engineer-in-Charge for approval.
(g) The surface shall be thoroughly cleaned and dusted. All dirt scales oil and grease shall be thoroughly removed before painting is started. The prepared surface shall be inspected and approved by the GE before painting is commenced. The weather shall not be foggy/rainy, dusty or windy. The suitability of the weather will be determined by the Engineer-in-Charge.
(h) No hair marks from the brush or clogging of paint buddles shall be left on the work. Surface shall ordinarily not be painted until it has dried up completely. Trial patches of paint shall be laid at intervals to check if drying is satisfactory.
M & L complete removal of existing treatment of any type/description such as distempering work, internal emulsion etc from internal surfaces of walls & ceiling with mechanical means/ grinder, then applying wall care putty on internal surfaces of walls/ceilings as required for desired smoothness and levelling of surfaces by using ready made wall care putty including sand papering and after filling the putty apply two coats of plastic emulsion over a coat of primer complete all specificed and as directed.
Note for item No 76:- (a) The plastic emulsion paint shall be of 1st quality manufactured by the standard firms of make as specified.
(b) The contractor shall inform the GE, within three weeks of the acceptance of the tender, the brand/names of the manufacturers of paint proposed to be used in the works and submit samples thereof and obtain prior written approval of GE before their use in works.
(c) The contractor shall when so required by the GE, produce certificate from the manufacturer or their representative to establish that the brands of paints purchased by the contractor from them, satisfy the requirements of the relevant Indian Standards. Tint of paint, will be approved by the GE.
(d) Paints shall be obtained direct from approved manufacturer or from their authorized agents only of respective brands and brought to site in sealed containers. The paint so procured shall be of first quality
(e ) Unless otherwise specified the tints of paint shall be as approved by the GE
(f) The contractor shall submit samples of the paints proposed for the work along with results of tests conducted in approved laboratory as directed by the Engineer-in-Charge for approval.
(g) The surface shall be thoroughly cleaned and dusted. All dirt scales oil and grease shall be thoroughly removed before painting is started. The prepared surface shall be inspected and approved by the GE before painting is commenced. The weather shall not be foggy/rainy, dusty or windy. The suitability of the weather will be determined by the Engineer-in-Charge.
(h) No hair marks from the brush or clogging of paint buddles shall be left on the work. Surface shall ordinarily not be painted until it has dried up completely. Trial patches of paint shall be laid at intervals to check if drying is satisfactory.
(j) The prepared surface after wall putty, the contractor will inform to the Engineer-in-Charge for site inspection before applying further surface finishes. Please note that the further surface finishes work will start only after approval of the prepared surface from the Engineer-in-Charge .
M&L preparation of old decorated plastered or unplastered surface of wall, brooming down or steel wire brushing down smoke soot, moulds mass, efflorescent , treading, oil, greasy spots and applying one coat oil bound distemper complete all as specified and as directed.
Note for Item No 86 :- (i) Surface will be throughly cleaned and approval of engg in charge will be taken before application of paint.
(ii)Paints shall be obtained direct from approved manufacturer or from their authorized agents only and brought to site in sealed containers. The paint so procured shall be of any approved make as per list of makes specified.
M&L preparation of old plastered surfaces of wall by using pressure washer, including removal of existing colour/treatment and dirt, dust etc and applying two coats of exterior emulsion paint complete all as specified and as directed.
Note for item No 89:- (a) The Exterior emulsion paint shall be of 1st quality manufactured by the standard firms of make as specified.
(b) The contractor shall inform the GE, within three weeks of the acceptance of the tender, the brand/names of the manufacturers of paint proposed to be used in the works and submit samples thereof and obtain prior written approval of GE before their use in works.
(c) The contractor shall when so required by the GE, produce certificate from the manufacturer or their representative to establish that the brands of paints purchased by the contractor from them, satisfy the requirements of the relevant Indian Standards. Tint of paint, will be approved by the GE.
(d) Paints shall be obtained direct from approved manufacturer or from their authorized agents only of respective brands and brought to site in sealed containers. The paint so procured shall be of first quality
(e ) Unless otherwise specified the tints of paint shall be as approved by the GE
(f) The contractor shall submit samples of the paints proposed for the work along with results of tests conducted in approved laboratory as directed by the Engineer-in-Charge for approval.
(g) The surface shall be thoroughly cleaned and dusted. All dirt scales oil and grease shall be thoroughly removed before painting is started. The prepared surface shall be inspected and approved by the GE before painting is commenced. The weather shall not be foggy/rainy, dusty or windy. The suitability of the weather will be determined by the Engineer-in-Charge.
(h) No hair marks from the brush or clogging of paint buddles shall be left on the work. Surface shall ordinarily not be painted until it has dried up completely. Trial patches of paint shall be laid at intervals to check if drying is satisfactory.
M&L preparation of old decorated surfaces of walls by using pressure washer, remove existing colour/treatment and dirt, dust etc ,applying one coat of wall care putty and then apply two coat of oil bound distemper of required shade over one complete all as specified and as directed by Engineer - in - Charge.
Note for Item No 98 :- (i)Surface will be throughly cleaned and approval of engg in charge will be taken before application of paint.
(ii)Paints shall be obtained direct from approved manufacturer or from their authorized agents only and brought to site in sealed containers. The paint so procured shall be of any approved make as per list of makes specified.
(iii) . Not less than 24 hours shall be allowed between two coats and the second or subsequent coat shall not be started until the preceding coat has become sufficiently hard to resist marking by the brush being used. In hot dry weather the preceding coat shall be slightly moistened before applying the subsequent coat.
(j) The prepared surface after wall putty, the contractor will inform to the Engineer-in-Charge for site inspection before applying further surface finishes. Please note that the further surface finishes work will start only after approval of the prepared surface from the Engineer-in-Charge .
M&L preparation of old decorated plastered or unplastered surface of wall, brooming down or steel wire brushing down smoke soot, moulds, mass, efflorescent , treading, oil, greasy spots including removal of existing colour/treatment, dirt, dust etc and applying two coats oil bound distemper complete all as specified and as directed.
Note for Item No 103 :- (i) Surface will be throughly cleaned and approval of engg in charge will be taken before application of paint.
(ii)Paints shall be obtained direct from approved manufacturer or from their authorized agents only and brought to site in sealed containers. The paint so procured shall be of any approved make as per list of makes specified.
(iii) . Not less than 24 hours shall be allowed between two coats and the second or subsequent coat shall not be started until the preceding coat has become sufficiently hard to resist marking by the brush being used. In hot dry weather the preceding coat shall be slightly moistened before applying the subsequent coat.
M&L Preparation of old painted wooden surface of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint using mechanical means complete all as specified and directed.
M&L Preparation of old painted steel surface of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint using mechanical means complete all as specified and directed.
Note for item No 107 & 108:- (a) All synthetic enamel paint, plastic emulsion paint shall be of 1st quality manufactured by the standard firms of make as specified.
(b) The contractor shall inform the GE, within three weeks of the acceptance of the tender, the brand/names of the manufacturers of paint proposed to be used in the works and submit samples thereof and obtain prior written approval of GE before their use in works.
(c) The contractor shall when so required by the GE, produce certificate from the manufacturer or their representative to establish that the brands of paints purchased by the contractor from them, satisfy the requirements of the relevant Indian Standards. Tint of paint, will be approved by the GE.
(d) Paints shall be obtained direct from approved manufacturer or from their authorized agents only of respective brands mentioned below and brought to site in sealed containers. The paint so procured shall be of first quality of any approved make as per list of makes specified. i. Berger Paints (Luxol), ii. Jenson & Nicholson (Brolac), iii. Shalimar Paints(Superlac), iv. Goodlass Nerolac (Nerolac), v. Asian Paints(Apcolite)
(e ) Unless otherwise specified the tints of paint shall be as approved by the GE
(f) The contractor shall submit samples of the paints proposed for the work along with results of tests conducted in approved laboratory as directed by the Engineer-in-Charge for approval.
(g) The surface shall be thoroughly cleaned and dusted. All dirt scales oil and grease shall be thoroughly removed before painting is started. The prepared surface shall be inspected and approved by the GE before painting is commenced. The weather shall not be foggy/rainy, dusty or windy. The suitability of the weather will be determined by the Engineer-in-Charge.
(h) No hair marks from the brush or clogging of paint buddles shall be left on the work. Surface shall ordinarily not be painted until it has dried up completely. Trial patches of paint shall be laid at intervals to check if drying is satisfactory.
Removing plant/Uprooting of vegetation growth including roots on wall/roof/parapet/Shaft portion , near pipes etc and applying acid treatment after removing roots for preventing regrowth and making good disturbed surfaces/area in superficial area exc 150sq.cm but n.exc 400 sq.cm and averaging depth not exceeding 10 cm by using PCC 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) or 10mm thick plastering in cement mortar 1:3 as required and finishing the surfaces to match with the existing surface complete all as specified and directed.
Note for item No 117 :- (a) Rate quoted by the tenderer shall be deemed to inclusive of double steel scaffolding.
(b) Contractor shall provided safety gears to his workers at his own cost and safety precaution to avoid accidents.
M & L complete removal of existing surface in shaft portion that includes bushes ,plants,tree roots, mould moss, oil grease etc. with steel scrubber . The surface shall than be broom to remove all dust and dirt and shall be clean with clear water and applying two coat of cement based paint over one coat of white wash complete all as specified and directed by engr in charge.
Note for Item No 120 :- (i)All unsound portion of the surface plaster shall be removed where directed to full depth of plaster in rectangular patches and replaster with CM 1:4 and finish the surface even and smooth without using extra cement
(ii) Rate quoted by the tenderer shall be deemed to inclusive of double steel scaffolding.
(iii) Contractor shall provided safety gears to his workers at his own cost and safety precaution to avoid accidents.
M&L Preparation of old painted brick, stone, concrete, or plaster surface of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint using mechanical means complete all as specified and directed.
Note for item No 124 :- (a) All synthetic enamel paint, plastic emulsion paint shall be of 1st quality manufactured by the standard firms of make as specified.
(b) The contractor shall inform the GE, within three weeks of the acceptance of the tender, the brand/names of the manufacturers of paint proposed to be used in the works and submit samples thereof and obtain prior written approval of GE before their use in works.
(c) The contractor shall when so required by the GE, produce certificate from the manufacturer or their representative to establish that the brands of paints purchased by the contractor from them, satisfy the requirements of the relevant Indian Standards. Tint of paint, will be approved by the GE.
(d) Paints shall be obtained direct from approved manufacturer or from their authorized agents only of respective brands mentioned below and brought to site in sealed containers. The paint so procured shall be of first quality of any approved make as per list of makes specified. i. Berger Paints (Luxol), ii. Jenson & Nicholson (Brolac), iii. Shalimar Paints(Superlac), iv. Goodlass Nerolac (Nerolac), v. Asian Paints(Apcolite)
(e ) Unless otherwise specified the tints of paint shall be as approved by the GE
(f) The contractor shall submit samples of the paints proposed for the work along with results of tests conducted in approved laboratory as directed by the Engineer-in-Charge for approval.
(g) The surface shall be thoroughly cleaned and dusted. All dirt scales oil and grease shall be thoroughly removed before painting is started. The prepared surface shall be inspected and approved by the GE before painting is commenced. The weather shall not be foggy/rainy, dusty or windy. The suitability of the weather will be determined by the Engineer-in-Charge.
(h) No hair marks from the brush or clogging of paint buddles shall be left on the work. Surface shall ordinarily not be painted until it has dried up completely. Trial patches of paint shall be laid at intervals to check if drying is satisfactory.
SAMYDOSS CONSTRUCTIONS
kcs builders
K S MUTHU CONSTRUCTTIONS
S KUMARAN
KRISHNA ENTERPRISES
p.chinnasamy
SKM CONSTRUCTION
GMS Builders
KSR AND COMPANY
S.RAMACHANDRAN
N SARAVANAN
M/s.Sai Agency
Shree Amritha builders
M SUNDARARAJAN
G Perumal and co
K.AYYAPPAN
T C KARUNANITHI
LAKSHMI ELECTRICAL ENTERPRISES
shalom constructions
jk construction
KUMAR AGENCIES
Neptune Engineers and Builders
s v m construction building & engineers
SAPTHAGIRI CONSTRUCTIONS
eurekaenterprises
stage.html
html • 0.12 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .