| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.2 LAccepted-AOC | L1 | Accepted-AOC Accepting being lowest | |
| 2 | L2₹28.8 L+₹1.2 L (4.27%)Rejected-Finance PLOT NO 76 CIV SOCIETY MUKUND NAGAR AHMEDNAGAR 414001 | AHMEDNAGAR | AHMEDNAGAR | MAHARASHTRA | 414001 | L2 | Rejected-Finance Rejected being other than lowest | |
| 3 | L3₹30.6 L+₹3.0 L (10.8%)Rejected-Finance | L3 | Rejected-Finance Rejected being other than lowest | |
| 4 | L4₹31.9 L+₹4.3 L (15.6%)Rejected-Finance | L4 | Rejected-Finance Rejected being other than lowest |
Tender Value
₹30.6 L
EMD Value
₹61,200
Closing Date
21 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Maj Pramod Kumar Tripathi
Military Engineer Services, Garrison Engineer (South) Ahmednagar - 414002
PROVN OF CERTAIN SANCTIONED WORKS AT AGE AURANGABAD UNDER GE (S) AHMEDNAGAR
2023_MES_577060_1
8950/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Aurangabad
Class D cat a (i)
8 documents required · 8 mandatory
₹500
Garrison Engineer (South) Ahmednagar
₹61,200
Yes
4 Mar 2023
24 Jan 2023
23 Feb 2023
24 Jan 2023
21 Feb 2023
7 Feb 2023
24 Jan 2023 - 31 Jan 2023
Amount
Dismantling of posts or struts (wood, steel or RCC) any section including taking out embeded portion in cocnrete, brick masonary and making good disturbed ground complete all as specified and as directed.
Dismantling of fencing wire mesh, any type complete all as specified and as directed.
Surface excavation n exc 30cm deep and averaging 15cm deep and getting out in soft/loose soil all as specified and as directed
Excavation in post holes in any type of soil, each not exceeding 0.50 Cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering and removing surplus soil to distance not exceeding 50m and making good surface all as specified and as directed.
Excavation in trenches, n exc 1.50m wide and n exc 1.50m in depth; for foundations, etc. or for manholes etc not exc 10 Sqm on plan and not exc 1.5m in depth and getting out in soft/loose soil all as specified and as directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick with soils all as specified and as directed.
Removing excavated soil to distance n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point all as specified and as directed.
M&L for hardcore of gauge n exc 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface all as specified and as directed.
M&L for PCC, 1:3:6 type C-0 using 12.5 mm graded stone aggregates for fixing of hold fast, filling in chowkats or frames and similar work including formwork if required complete all as specified and as directed.
M&L for PCC, 1:3:6, type C2, using 40 mm graded stone aggregates as in foundations, filling and mass concrete all as specified and as directed.
M&L for PCC, 1:3:6 type C2, using 40 mm graded stone aggregates as in surface channels and drain all as specified and as directed.
M&L for PCC, 1:3:6 type C1, using 20 mm graded stone aggregates as in kerbs, rounded or chamfered angles on edges for interlocking tiles etc and like all as specified and as directed.
M&L for precast RCC 1:2:4, type B-1 using 20 mm graded stone aggregates as in cover slabs of manholes including necessary forms, moulds etc complete all as specified and as directed
M&L for RCC 1:1½:3, type A-1 using 20mm graded stone aggregates as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as specified and as directed.
M&L for RCC 1:1½:3, type A-1 using 20mm graded stone aggregates as in beams, cantilevers, bressummers, lintels over 1.5m span all as specified and as directed.
M&L for 40mm thick damp proof course to horizontal or vertical surfaces in PCC 1:2:4, type B0 using 12.5mm graded stone aggregates including necessary form work complete all as specified and as directed.
M&L for brick work with fly ash bricks, old size, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and as directed.
M&L for brick work with sub class B bricks, old size, straight or curved on plan exc 6m mean radius, built in cement mortar 1:4 complete all as specified and as directed.
Use and waste formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for rough finished flat surfaces of concrete all as specified and as directed.
Use and waste formwork to sides and soffits of floor or roof beams, beam haunch- ings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. for rough finished flat surfaces of concrete all as specified and as directed.
S&F second class hard wood, chowkats or frames, wrought, framed, rebeated on the solid, rounded or chamfered, put together with glue, pinned at joints and fixed to wall complete all as specified and as directed.
S&F 35 mm thick, second class hard wood, plain framed, factory made, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm thick veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated all as specified and as directed.
S&F 100 mm size butt hinges, medium weight, cold rolled mild steel, and fixed all as specified and as directed.
S&F 200 mm long aluminium barrel tower bolt of extruded section all as specified and as directed.
S&F 150 mm size, aluminium handle anodised fabricated type all as specified and as directed.
S&F galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aparture 1.18 mm fixed to steel windows etc complete all as specified and as directed.
M&L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally, hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and as directed.
All as per serial item No 27 but 6mm to 8mm dia.
Add as per item No 27 but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and as directed.
M&L for mild steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded all as specified and as directed.
M&L for mild steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded all as specified and as directed.
M&L for mild steel framed work such as grills, grating, guard bars etc with end of bars shoulderd and/or riveted, welded or forged into spikes, framed guard bars iron doors and similar work conforming to Fe 290 Gde E-165 all as specified and as directed.
S&F mild steel angle/flat iron posts/strut for securing barbed/chain link fencing of any description including drilling holes, notching for wire etc, conforming to Fe 290 (Gde -E-165) complete all as specified and as directed.
S&F mild steel screw bolts (machine made), 10mm dia of neck and 65mm long with hexagonal or square heads at one end and screwed the other, each screwed end to be fitted with washers and one hexagonal or square nut, fixed to posts complete all as specified and as directed.
S&F mild steel bolts, exc 300mm long, dia of neck exc 12 but n exc 20mm, purpose made with hexagonal or square head one en the other, each screwed end to be fitted with washers and one hexagonal or square nut complete all as specified and as directed.
Supply only chain link fencing net mild steel galvanised, made out of GI wire of 8 to 10mm gauge, aperature not exceeding 65 mm, weight not less than 3.5 kg/sqm all as specified and as directed. Note : Payment shall be allowed after ascertaining weight of chain link as per actual at site through BOO as ordered by GE.
Fixing only chain link fencing, any mesh any type including securing bolts etc complete all as specified and as directed.
S&F mild steel round bars as in line bars for fixing chain link fencing, conforming to FE 290 (Gde -E-165) complete all as specified and as directed.
S&F structural steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes grade St-240 complete all as specified and as directed.
M&L for mild steel work as in wind ties for roof sheets including securing bolts complete including all necessary drilling, bolting or riveting etc and similar work conforming to Fe-290 Gde-E-165 complete all as specified and as directed.
S&F in repairs, galvanized 2 strand, steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossings with and provision of galvanized mild steel wire, staples or steel pins etc complete all as specified and as directed.
M&L for prepainted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of colour as approved by GE, having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and as directed.
M&L for 75mm thick PCC 1:4:8, type D2 using 40 mm graded stone aggregates as in sub base all as specified and as directed.
M&L for 100mm thick PCC 1:4:8, type D2 using 40 mm graded stone aggregates as in sub base all as specified and as directed.
M&L for 40mm thick PCC 1:2:4, type B-0 using 12.5mm graded stone aggregates as in floor, finished even and smooth without using extra cement all as specified and as directed.
M&L for 75mm thick PCC 1:3:6, type C2 (using 40mm graded stone aggregate) as in plinth protection, etc finished the surface even and smooth without using extra cement including provision of joint of size 10 mm wide & 10 mm deep and filling with bitumen mastic joint filling at every 3m length and at corners complete all as specified and as directed.
M&L for forming construction joint 30mm deep and 10mm wide and filled with sealing compound grade A complete all as specified and as directed.
M&L for precast cement concrete interlocking paver blocks (glossy finish/ rubber matt finish) of 80 mm thick ,hydraulically pressed, cemented blocks of grey cement with pigments,(glossy finish/ rubber mat finish), factory made, M-40 grade as in floor, laid over & including 25 mm thick sand cusion and including filling of interstices with fine sand complete all as specified and as directed. Note Size, shape & pattern of tiles shall be as decided.
M&L for 10mm thick rendering in cement mortar 1:6 on other than fair faces of brick work or concrete surfaces, finished even and smooth with thin layer of sagol complete all as specified and as directed.
M&L for rendering 15 mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces finished surfaces even and fair all as specified and as directed.
M&L for rendering 5 mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces as in ceiling, finished surfaces even and smooth without using extra cement all as specified and as directed.
M&L for preparation of new plastered surfaces of walls and applying three coats of white wash all as specified and as directed.
M&L for preparation of new surfaces of ceiling and applying three coats of white wash all as specified and as directed
M&L for preparation of new plastered surfaces of walls and applying two coats of cement base paint over a coat of primer all as specified and as directed
M&L for 3 mm thick figured glass, pin head type and glazing with oil putty in square n exc 0.5 Sqm in each pane all as specified and as directed
M&L for preparing new wood or wood based surfaces of any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and as directed
M&L for preparing new steel surfaces of any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide primer all as specified and as directed.
M&L for preparing new steel surfaces of any description, not exceeding 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed.
M&L for reinforced cement concrete pipes 200mm dia, class NP2, laid and jointed complete with collars all as specified and as directed
M&L for PCC 1:4:8, type D2 using 40mm graded stone aggregates as in bed to drain pipes, 200mm dia including packing under and completely surrounding pipes with concrete after laid all as specified and as directed
S&F room window type air conditioner, electric driven (single phase), cooling capacity 4500 K Cal per hour ( 1.5 Ton), BEE 5 star rated & making fixing arrangement with Suitable size of MS angle or making space in Brick/Stone wall suitable for air conditioner and making surface smooth with cement plastering etc including testing and commissioning complete all as specified and as directed.
S&F heavy duty wall mounted voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 135 V to 280 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA complrte all as specified and as directed
M&L for point wiring complete on surface of wall (open) type with two runs of 1.5 sqmm for phase and neutral, single core, multistranded copper conductor cable of 1100 Volts grade,conforming to IS-694 1990, PVC insulated and unsheathed , FRLS cable drawn through and including PVC casing and caping (ISI marked) and its accessories such as Tee, elbow, jointer, elbow corner etc. fixed on surface of walls, coloumns/ beams alongwith 1.5 Sqmm copper conductor cable (multistranded) PVC insulated and unsheathed FRLS cable as earth wire connected to common earth dolly at one end and metalic bodies of luminaire/ fan at other end including PVC folding boards for mounting switches, sockets, fan Regulators, accessories etc as specified and directed for one light point or one fan point controlled by one, one way switch . NOTE: 1.Proper colour coding shall be adopted for wiring (for phase-RED,YELLOW,BLUE for Earth-Green and Neutral-Black) 2. All points shall be earthed up to fixtures i.e holders,tube lights,all lights,ceiling lights,bulkhead lights,bldg security lights etc.
All as per serial item No. 63 but on independent board.
All as per serial item No. 63 but for power point 3 pin switch socket 15 Amps with PVC copper conductor cable, multistranded unsheathed 4.0 Sqmm on independent board including one run of 4.0sqmm multistranded PVC copper conductor cable for earth continuity and including PVC caping caping fixed on wallincludubf PVC box 2mm complete all as specified and as directed.
S&F modular switch, single pole, one way 5/10 Amps 1 module complete all as specified and as directed.
S&F modular switch, single pole, one way 16 Amps 1 module complete all as specified and as directed.
S&F modular socket 6 Amp 2/3 pin combined 2 module complete all as specified & as directed.
S&F modular socket 6A/16 Amp 2/3 pin combined 2 module complete all as specified and as directed.
S&F ceiling rose, surface PVC 50mm dia, 3 terminals including PVC mounting block white/ivory finish all as specified and as directed.
S&F LED lights fitting 1x18W, 220V, AC, decorative box type with driver, holder including LED tube light, connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
S&F LED bulk head luminaire of any capacity 10/11 watt with all accessories prewired twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed.
M&L for sub main wiring with 2 runs of 4 sqmm, single core, PVC insulated & unsheathed FRLS cable conforming to IS-694, 1100 volts with copper conductor, multi stranded drawn in and including suitable size heavy grade casing caping (ISI marked) with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 4 sqmm single core PVC insulated & unsheathed FRLS copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and any type of conduit complete all as specified and as directed. NOTE: 1.Proper colour coding shall adopted for wiring (for phase-RED,YELLOW,BLUE for Earth-Green and Neutral-Black 2.Three runs of 4 sq.mm cable and one run of PVC casing & caping shall be measured as one unit.
S&F MCB DB, double door, 4 way, SPN with suitable rated bus bar, 240 volts complete all as specified and as directed.
S&F MCB SP, AC 240 V, 6 to 32 Amps, 10 KA capacity ,'c' series, making connection with suitable size of copper lugs etc complete all as specified and as directed.
S&F MCB SPN, AC 240 V, 40 to 63 Amps, 10 KA capacity ,'c' series, making connection with suitable size of copper lugs etc complete all as specified and as directed.
S&F sheet metal enclosure, SPN with 2 pin ,earth plug and socket complete with and including single pole, 20 Amps MCB, 240V complete all as specified and as directed
M&L in repairs/replacement of earthing complete with galvanized steel earth plate electrode 60 cm X 60 cm X 6.0 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level, connecting to the GI wire 4 mm dia , by means of nut bolts, check nuts and washer of the GI . Earth wire connected upto main earth point/DBs alongwith 15mm dia GI pipe, medium grade, including provision of concrete pit in PCC (1:2:4) type B-1 using 20 mm graded stone aggregates with 40 mm thick RCC (1:2:4) cover with reinforced with XPM (weight not less than 4 Kg / Sqm) and frame of angle iron 25mm X 25 mm X 3mm with lugs 2 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 mtr, all as per electric plate No 3 of SSR Part I 2009 and connection to earth test point all as specified including testing on completion.
Supply and laying 1100 volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1m apart including 4mm suspension wire one twin core cable flat of stranded multistrand conductor of size 4Sqmm complete all as specified and directed.
M&L for 6 Sqmm, 2 core, 1100 volts grade, heavy duty, multi stranded, aluminium conductor cable, PVC insulated, served with inner sheathing of PVC tape and overall PVC sheathed in service connection flat/circular cable including taking down existing cable complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10.0 sq mm 2 core complete all as specified and as directed
Supply and spreading sand for cusioning of electric cable, 8 cm below the cable and 15 cm above the cable, punned to total thickness of 18 cm complete all as specified and as directed. Note : Punned thickness only will be considered for payment.
Supply and laying unreinforced precast concrete cable cover class LV type-1, flat, size 250 mm x 150 mm x 40 mm complete all as specified and as directed.
S&F LED street light fitting, 100 Watt, 230 V AC, outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete etc with 2.5 Sqmm Copper Cable up to 10 Mtr with all connection & including taking down old unserviceable light fittings of any type/cap complete all as specified and as directed
S&F in repairs, brackets for street light fitting 1.5Mtr long, made out from GI pipe suitable for street light fitting including mild steel clamps and nut bolts etc complete all as specified and as directed.
HG PATHAN CONSTRUCTION COMPANY
M/s S.R lahoti
M/S Tirupati Goroba Shendge
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .