Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹4.8 LAdmitted-Finance 0 HUSAINGANJ HATHGAON ROAD WARD 1 DIGHUWARA HATHGAM NAGAR PANCHAYAT HATHGAM FATEHPUR UTTAR PRADESH 212652 | FATEHPUR | UTTAR PRADESH | 212652 | -8.00% | ₹4.8 L | L1 | Admitted-Finance |
Tender Value
₹5.2 L
EMD Value
₹10,400
Closing Date
17 Mar 2026, 3:00 pmClosed
Executive Engineer (Elect)/KBZ
OFFICE OF THE EX. ENGINEER (ELECT)-IV/KBZ TOURIST CAMP SITE, J.L. NEHRU MARG, DELHI-02
Improvement/Development of Electrical installations and other allied Works for Newly Constructed Registration Counter at PUHC Naraina in MC Primary School Nursery Building G Block, Naraina Ward No.139 in view of AAM SC under Karol Bagh Zone
2026_MCD_270479_1
NIT No 50/EEE/KBZ/MCD/2025-26
Open Tender
Electrical Works
60 days
Karol Bagh Zone
Please refer Tender documents.
5 documents required · 5 mandatory
₹590
₹10,400
17 Mar 2026
11 Mar 2026
17 Mar 2026
11 Mar 2026
17 Mar 2026
11 Mar 2026
Wiring for light/fan point/exhaust fan point call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recess medium class PVC conduit with modular switch, modular plate,suitable size GI box and earthing the point with 1.5sqmm FR PVC insulated copper conductor single core cable etc as required. Group C
Wiring for light / power plug with 2 X 4 sqmm FRLSPVC insulated copper conductor single core cable in surface / recessed medium Class PVC conduit alongwith 1 no 4sqmm FRPVC insulated copper conductor single core cable for loop earthing as required.
Rewiring for light point/fan point/exhaust point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as reqd.
S/D following size of FRLS PVC insulated copper conductor 1 core cable in existing surface/recessed /PVC/ Steel conduit as reqd.(a) 3x2.5 sq mm
S/D following size of FRLS PVC insulated copper conductor 1 core cable in existing surface/recessed /PVC/ Steel conduit as reqd.(a) 6x2.5 sq mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface / recessed including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.(b) 25 mm
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 amp switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 amp socket outlet
Supplying and fixing following size GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 8 Module (125 mmX125 mm)
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as reqd. Upto 450 mm sweep
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (b) 63 amps
Supplying and fixing following rating, breaking capacity and pole MCCB with thermomagnetic release and terminal spreader in existing cubicle panel board including drilling holes in cubicle panel, making connections etc as required.(a) 100 A, 16KA, TPMCCB
Supplying and fixing following rating, breaking capacity and pole MCCB with thermomagnetic release and terminal spreader in existing cubicle panel board including drilling holes in cubicle panel, making connections etc as required.(a) 200 A, 25KA, TPMCCB
Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt) as required
Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal ( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req. 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum).
Supply of 15" (380mm) sweep 1400 rpm exhaust fan heavy duty complete with shutter, blade etc as reqd.
Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm) (a) 18-22 watt
Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140 270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K / 6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). CRCA Sheet Body (Thickness ≥ 0.50 mm) (a) 40 watt
Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.lKV grade conforming to IS- 7098 of following size:- (a) 2x10 sqmm
Supplying, installation, Testing & Commissioning of following capacity at full load (Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input, Single Phase output AC Supply. The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch along with provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. The UPS systems shall be Microprocessor based Digital Control, using Insulated Gate Bipolar Transistor (IGBT)'s both for the rectifier & inverter with PWM (Pulse Width Modulation) Technology. The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be >95% at 100% non-linear loads. Current total harmonic distortion (ITHD)/ total demand distortion (TDD on the input grid shall be < 5% at 100 %load. (The required LC filters shall be included in UPS cost), extreme power factor kit to be include to limit the input pf to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ) however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC single phase 160-270V 50 Hz and delivering output AC supply true sine wave single phase 220/230/240 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins and 150% for 1 minute. Operating temperature 0 to 40 deg C, Relative humidity 0-95% non condensing, noise level less than 60db at 1 meter distance, Protection for Under voltage, over voltage, abnormal output voltage, battery over charging, output over current, short circuit, battery deep discharge , 10 KV surge. Display for watt/VA,Amp and Voltage power parameters etc. UPS shall comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI) type UPS (as per standard IEC 62040-1, 2 & 3) . The UPS should be with IGBT Based Inverter Technology, Communication RS232/RS485/SNMP port open protocol for BMS integration as per approved by Engineering in charge. Required battery racks, DC breaker of suitable rating and interconnecting copper conductor cable of suitable size and connectors and all required accoseries are inclusive in the cost. The UPS should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc. (a) 3KVA
S/I/T/C of 4 KVA Voltage Stabilizer having input voltage 150V-270V and output voltage 195-245V
Supply , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R 407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). Inverter Type - Cooling only- 1.5 TR with 5 Star BEE Rating
SITC of 4MP varifocal lens Bullet IP Camera with following specifications:- Image Sensor: 1/3 4MP CMOS Minimum Illumination: 0.05 lux color, 0 lux with IR or better ** Shutter Speed:1/3 – 1/100,000 s Frame Rate: 20 fps or better ** Lens: 3.6 to 10mm Varifocal lens Video Compression: H.265 or better ** S/N Ratio: >45dB Resolution: (2650x1440) or better ** Protocol: should comply to IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE,DDNS, IEEE802.1X IR Range: Minimum:30m Operating Temperature: -20 to 55 deg Cent Weatherproof Standard: IP66 or better ** Safety standard: UL
SITC of 2MP varifocal lens Dome IP Camera with following specifications:- Image Sensor: 1/2.8 2MP CMOS or better** Minimum Illumination: 0.1 lux color, 0 lux with IR or better ** Shutter Speed:1/3 – 1/100,000 s Frame Rate: 25 fps or better ** Lens: 2.8 to 12mm Varifocal lens Video Compression: H.265 or better ** S/N Ratio: >45dB Resolution: 1080p(1920x1080) or better ** Protocol: should comply to IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE,DDNS, IEEE802.1X IR Range: Minimum 20m Operating Temperature: -20 to 50 deg Cent Weatherproof Standard: IP66 or better ** Safety standard: UL
SITC of 8 channel NVR with the following specifications: Camera resolution:upto8MP Interface: 1 HDMI, 1VGA minimum Compression :H.265or better Network Throughput :80Mbps or better** USB Port: 2 USB port (USB2.0)minimum Hard disk interface: 1 SATA port suitable for 6TB each Protocol: IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE,DDNS Operating temp: -10 to 55 deg Cent Safety standard: UL
SITC of 8 TB surveillance HDD
SITC of 8 port Giga PoE switch, 8(PoE 10/100) + 2(10/100) port long distance switch.
SITC of following rack capacity with glass front door, steel rear door, power supply, MCB, cable manager, drawer shelves and wiring channels to accommodate CCTV systems equipment and complete with accessories as reqd.8 U
SITC of full HD LED Monitor,32 INCHES complying with the following specifications: Resolution : Full HD : 1920 x 1080 or better Backlight : LED Brightness : 300 NITS min. Contrast : 1200 : 1 or better Power supply : 230v + / - 10%, 50 Hz at site with connections and along with all accessories etc. Complete as required.
SITC of IP 65 box (without PoE Switches) of dimention 310 mm X 160 mmX 140 mm on pole or wall with suitable arrangement for support/ installation of 8 port Giga PoE switch and 1 nos 15/16 amp modular switch socket set.
3 run of cable
Supplying and fixing of following sizes of medium class PVC conduit /baton along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required 25 MM
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.46 MB
Conditionravinder.pdf
Tender Documents • 0.41 MB
BOQ_315334.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid