Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance 350 683 THIRUVOTTIYUR HIGH ROAD TONDIARPET CHENNAI TAMIL NADU 600081 | CHENNAI | TAMIL NADU | 600081 | Admitted-Finance |
| 3 | Admitted-Finance NO 12 HARIKRISHNAPURAM SAWYERPURAM TUTICORIN THOOTHUKUDI TAMIL NADU 628251 | TUTICORIN | TAMIL NADU | 628251 | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
Tender Value
₹33.6 L
EMD Value
₹67,240
Closing Date
26 Feb 2020, 2:30 pmClosed
The Chief Mechanical Engineer
O/o The Chief Mechanical Engineer 7th Floor Centenary Building No.1, Rajaji Salai, Chennai-600 001
AMC FOR FIRE FIGHTING LINES PERTAINING TO 16 INCH DIA TOWER MONITOR LINE, 14 INCH DIA FIRE HYDRANT LINES FROM OLD PUMP HOUSE TO BD I, NEW PUMP HOUSE TO BD I AND ALSO NEW PUMP HOUSE TO M s. IOC, FORESHORE TERMINAL AT OIL DOCK.
2020_ChPT_541812_1
MEE/06/2020/Dy.CME (MP/OH)
Open Tender
Marine Works
Works
365 days
Oil Dock, Royapuram
As per Tender Condition
5 documents required · 5 mandatory
₹0
₹67,240
Yes
18 Mar 2020
5 Feb 2020
27 Feb 2020
5 Feb 2020
26 Feb 2020
15 Feb 2020
Supply of fine river sand for cement coatings to a uniform thickness of 15mm (cement and sand ratio 1:3) of various sizes of pipelines, Bends, T-Connections and reducers, etc. as detailed in Schedule-A. Note: Supply may be required on need basis at the time of fabrication
Supply of Cement for cement coatings to a uniform thickness of 15mm (cement and sand ratio 1:3) of various sizes of pipelines, Bends, T-Connections and reducers, etc. as detailed in Schedule-A. Note: Supply may be required on need basis at the time of fabrication
Supply of steel pipe 10 3/4" dia ERW pipe (273.10 m,) x 0.365" (9.3mm) wall thickness as per IS 3589 FE 410 with hydrostatic pressure not less than 100 kg / sq.cm of random length 4 to 7 metres. Note : Manufacturer / Govt. approved laboratory test certificate and Guarantee certificate for 12 months should accompany with the supply.
Supply of different sizes of cast steel 90 degree bends as mentioned below : i) 16" dia 90 deg bend
ii) 14" dia 90 deg bend
iii) 10" dia 90 deg bend
iv) 8" dia 90 deg bend
v) 4" dia 90 deg bend
Supply of HT Bolts & Nuts and metallic gaskets as follows required for the above works. i) M24x110 mm long
ii) M22x110 mm long
iii) M20x100 mm long
iv) M20x90 mm long
v) M18x90 mm long
vi) M16x75 mm long
vii) 16” dia Metallic Gasket, 3 mm thick
viii) 14” dia Metallic Gasket, 3 mm thick
ix) 12” dia Metallic Gasket, 3 mm thick
x) 10” dia Metallic Gasket, 3 mm thick
xi) 8” dia Metallic Gasket, 3 mm thick
xii) 4” dia Metallic Gasket, 3 mm thick
Supply of M.S. Flanges (Class 150) of the following sizes as detailed in Schedule-A. i) 16” dia M.S. Flange
ii) 14” dia M.S. Flange
iii) 12” dia M.S. Flange
iv) 10” dia M.S. Flange
v) 8” dia M.S. Flange
vi) 6” dia M.S. Flange
vii) 4” dia M.S. Flange
Supply of Epoxy Zinc Rich Primer for painting of renewed portions
Supply of Epoxy Post Office Red for painting of renewed portions
Description of Work / Item(s)
Labour Charges for replacing of punctured / weakened portions of the fire fighting pipelines including cutting, fabrication, cement coating, laying, aligning, welding in the existing main line as detailed in Schedule-A. Note: Necessary steel pipes will be supplied by the Trust. i) 8” dia Pipeline
ii) 10” dia Pipeline
iv) 14” dia Pipeline
v) 16” dia Pipeline
vi) 4” dia Pipeline without cement coating
vii) 6” dia Pipeline without cement coating
Labour Charges for cement coating and laying, aligning, welding in the existing main line of the following firm supply items. i) 16” dia 90 deg Bend
ii) 14” dia 90 deg Bend
iii) 10" dia 90 deg Bend
iv) 8" dia 90 deg bend
v) 4" dia 90 deg bend (without cement coating)
Labour Charges for fabrication, cement coating, laying, aligning and welding of the following items from the Trust supplied pipes. i) 16" dia "T" connection
ii) 14" dia "T" connection
iii) 10" dia "T" connection
iv) 16"/14" dia Reducer
v) 14" / 10" dia Reducer
vi) 14" / 8" dia Reducer
vi) 8" / 6" dia Reducer
Labour Charges for replacing of gate valves and NRVs in fire fighting lines including gaskets, bolts & nuts, etc. Note : The necessary gate valves & NRVs will be supplied by the Trust. i) 14" dia Gate Valve
ii) 12” dia Gate Valve
iii) 8” dia Gate Valve
iv) 4” dia Gate Valve
v) 12” dia NRV
vi) 10” dia NRV
Labour Charges for Cutting and welding of doubler plates / patch plates on punctured / weakened portions as detailed in Schedule-A. Note : Necessary pipes will be supplied by the Trust. i) 500 mm x 500 mm
ii) 300 mm x 300 mm
iii) 200 mm x 200 mm
Charges for cutting and welding of flanges in fire fighting lines as detailed in Schedule-A. i) 16” dia M.S. Flange
ii) 14” dia M.S. Flange
iii) 12” dia M.S. Flange
iv) 10” dia M.S. Flange
v) 8” dia M.S. Flange
vi) 6” dia M.S. Flange
vii) 4” dia M.S. Flange
Labour Charges for removing, reconditioning, refixing and commissioning of foot valve assembly with vertical suction pipe as detailed in Schedule-‘A’ in fire fighting pumps at Old Pump House and New Pump House. i) 14”/`16” dia foot valve assembly with vertical suction pipe at Old Pump House.
ii) 4” dia foot valve assembly with vertical suction pipe of PM pump at Old Pump House.
iii) 3” dia foot valve assembly with vertical suction pipe of PM pump at New Pump House.
iv) 14”/`16” dia foot valve assembly with vertical suction pipe at New Pump House.
Labour Charges for painting of renewed portions by one coat of Epoxy Zinc Rich Primer and two coats of Epoxy Post Office Red
Strengthening of the Foundation of the Engine of CU4A pumpset at OPH i) The engine should be firmly supported in the existing position and the concrete foundation on both sides of the engine in the bell housing area to demolished
ii) The foundation of the engine on both sides to be fabricated with steel structure and fixed with engine and foundation bed with providing necessary rubber mount.
iii) The engine to be checked for alignment with the pump and corrected if requried for smooth running of the pumpset. Note: All the required materials for the above works to be supplied by the firm.
Charges for old pipes sent to Trust's RSA yard by his own transport arrangement.
Annai Enterprises
VPR ENGINEERING WORKS
MANUEL CORREYA ENGINEERING CONTRACTORS
Annai Enterprises
VOYAGER MARINE SERVICES INDIA PRIVATE LIMITED
MANUEL CORREYA ENGINEERING CONTRACTORS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .