Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹25.7 LAccepted-AOC 19 62 1ST FLOOR WEST MOTI BAGH SARAI ROHILLA NEW DELHI 110035 | NEW DELHI | NEW DELHI | DELHI | 110035 | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹26.4 L+₹28,860 (1.10%)Rejected-AOC B 3 105 PASCHIM VIHAR NEW DELHI 110063 | WEST | DELHI | 110063 | L-2 | Rejected-AOC L-2 | |
| 3 | L-3₹45.5 L+₹19.4 L (74.3%)Rejected-AOC D1C 47A JANAK PURI NEW DELHI 110058 | NEW DELHI | DELHI | DELHI | 110058 | L-3 | Rejected-AOC L-3 |
Tender Value
Refer Docs
EMD Value
₹76,500
Closing Date
25 Feb 2023, 6:00 pmClosed
GE I RND DELHI
MILITARY ENGINEER SERVICE, GARRISON ENGINEER (I) RND, LUCKNOW ROAD, TIMARPUR, DELHI-110054
REPAIR AND MAINT OF PACKAGE TYPE UNIT 5TR VRF EQUIPMENT OF 22 TR AND REPAIR/MAINT OF COOLING APPLIANCES INSTALLED IN SSPL UNDER GE I RnD DELHI
2023_MES_575681_1
GE/RND-101/DLI/2022-2023
Open Tender
Civil Works
Item Rate
180 days
Delhi
Class-D, Cat-c(i)
2 documents required · 2 mandatory
₹500
GE I RND DELHI
₹76,500
Yes
3 Apr 2023
18 Jan 2023
27 Feb 2023
18 Jan 2023
25 Feb 2023
13 Feb 2023
Amount
M&L for charging of Refrigerant R-22 complete including testing complete all as specified and directed.
M&L for charging of Refrigerant R-410A including testing complete all as specified and directed.
M&L for repair to leakage including brazing, Nitrogen gas testing by holding the pressure for minimum 24 hours and recommissioning of 22 TR VRF Unit complete all as specified and directed.
All as per item Ser No. 3.00 above but 5 TR.
S&F in repair refrigerant copper pipe 15mm dia, 0.64 mm wall thickness complete all as specified and directed.
S&F in repair refrigerant copper pipe 12 mm dia, 0.64 mm wall thickness complete all as specified and directed.
S&F in repair refrigerant copper pipe 5/8" (15.88 mm) dia 0.60 mm thick including foam insulation for copper tube wall complete all as specified and directed.
S&F in repair refrigerant copper pipe 3/8" (9.52 mm) dia 0.55 mm thick including foam insulation for copper tube wall complete all as specified and directed.
S&F in repair control PCB suitable for VRF AC 22 TR outdoor complete all as specified and directed.
S&F in repair inverter PCB suitable for VRF AC 22 TR outdoor complete all as specified and directed.
S&F in repair power transistor suitable for VRF AC 22 TR complete all as specified and directed.
S&F in repair primary unit Compressor hermatically Sealed suitable for VRF AC 22 TR complete all as specified and directed.
S&F in repair secondary unit Compressor hermatically Sealed suitable for VRF AC 22 TR complete all as specified and directed.
S&F in repair diode module suitable for 22 TR AC Plant complete all as specified and directed.
S&F in repair of resistor suitable for VRF AC 22 TR outdoor complete all as specified and directed.
S&F in repair noise filter PCB suitable for VRF AC 22 TR outdoor complete all as specified and directed.
S&F in repair Indoor unit PCB suitable for 22 TR AC Plant complete all as specified and directed.
S&F in repair IDU remote sensor eye receiver suitable for 22 TR AC Plant complete all as specified and directed.
S&F in repair ODU fan motor suitable for 22 TR AC Plant complete all as specified and directed.
S&F in repair ODU sensor set suitable for 22 TR AC Plant complete all as specified and directed.
Quarterly inspection of all 22 TR VRF of make MISHI BHUSHI unit from Authorised dealer complete all as specified and directed. Note:- The inspection shall be carried out by the service Engineer of OEM/authorised dealers having the experience with company not less than 5 years. Inspection report shall also be submitted to the GE /Engineer-in-Charge duly signed by authorised representative, contractor etc. The rates for transportation, lodging boarding etc if any required shall deemed to be inclused in quoted unit rates.
S&F in repair outdoor PCB suitable for Package type AC plant 5 TR complete all as specified and directed.
S&F in repair indoor PCB suitable for Package type AC plant 5 TR complete all as specified and directed.
S&F in repair indoor cooling coil suitable for Package type AC plant 5 TR complete all as specified and directed.
S&F in repair compressor hermatically Sealed suitable for Package type AC plant 5 TR complete all as specified and directed.
M&L for Soft Chemical servicing of 22 TR VRF AC Plant indoor Units including minor parts complete all as specified and directed.
M&L for Soft Chemical servicing of 22 TR VRF AC Plant Outdoor Units including minor parts complete all as specified and directed.
M&L for Soft Chemical servicing of 05 TR package type AC Plant indoor Units including minor parts complete all as specified and directed.
M&L for Soft Chemical servicing of 05 TR package type AC Plant Outdoor Units including minor parts complete all as specified and directed.
M&L for Servicing of the window AC 1.5/2 ton capacity of any make, including oiling/greasing the blower motor, cleaning the evaporator condenser coils externally to remove the dust, replacement of defective thimbles etc and re-fixing the air conditioner at its original position by the experienced refrigeration mechanic complete all as specified and directed. Note :- (i) Any unserviceable spare parts & gas charging required to be replaced shall be measured & paid separately under respective item. (ii) The cost of dismantling, taking out window AC 1.5/2.0 ton from window and shifting to location where directed for proper washing and servicing and refixing the same shall deemed to be included in unit rate quoted.
All as per item Ser No. 30.00 above but for split type AC/Inverter type/casette type AC 1.5/2.0/4.1 Ton.
M&L Fan Motor of AC (Window/ Split Type) 1.5 TR Capacity of approved Make and required Size to suit existing AC including taking out the unserviceable Fan Motor from the AC, complete all as specified and directed.
All as per Item Ser No 32.00 above but AC (Window/Split Type). 2.0 TR Capacity
M&L for rewinding Fan Motor of AC 1.5/2.00 TR Capacity, (Window/Split Type) of any Make with Super Enameled Copper Wire of appropriate Gauge and Quantity including taking out burnt Winding, complete all as specified and directed.
M&L for Air Circular Blower Fan Motor of AC (Split Type), 1.5 TR/2.0/3.00TR Capacity including taking out unserviceable Air circular Blower Fan Motor complete all as specified and directed.
M&L for Air Filter suitable of AC (Window type) 1.5 TR/2.0 TR Capacity including taking out unserviceable Air Filter from AC complete all as specified and directed.
M&L for Air Filter suitable for AC (Split type) 1.5 TR/2.0 TR Capacity including taking out unserviceable Air Filter complete all as specified and directed.
M&L for Capacitor Running 36 mfd – 45 mfd suitable for new/star rated for AC (Window/Split Type) 1.5 TR/2.0 TR Capacity including taking out unserviceable Capacitor from AC complete all as specified and directed.
M&L for Capacitor Starting 80 mfd – 120 mfd suitable for old ones AC (Window/Split Type) 1.5 TR/2.0 TR Capacity including taking out unserviceable Capacitor from AC complete all as specified and directed.
S&F Fan Motor Blades AC (Window/Split type) 1.5/2.0 TR capacity including taking out unserviceable Blades of Fan Motor from AC complete all as specified and directed.
S&F Fan Motor Capacitor 4 mfd of suitable for new/star rated AC (Window/Split Type) 1.5/2.0TR capacity including taking out unserviceable Fan motor capacitor from AC complete all as specified and directed.
S&F Fan Motor Capacitor 6 mfd suitable for old ones AC (Window/Split Type) 1.5/2.0TR capacity including taking out unserviceable Fan motor capacitor from AC complete all as specified and directed.
S&F Front Plastic Grill of AC (Window type) 1.5 TR/2.0 TR Capacity including taking out unserviceable Front Plastic Grill from AC all as per existing and complete all as specified and directed.
S&F Front Plastic Grill for inner unit of AC (Split type) 1.5 TR/2.0 TR Capacity including taking out unserviceable Front Plastic Grill from AC all as per existing complete all as specified and directed.
M&L Runner for air blower motor of AC (split type) AC 1.5/2.00TR capacity as per site requirement) including Runner of Air Blower Motor from AC all as per existing complete all as specified and directed.
M&L Single Pole Contactor 25A Capacity, MR 11W type as approved suitable for AC (Split Type) including taking out unserviceable Single Pole Contactor complete all as specified and directed.
M&L Starting Relay of AC (Window/Split Type) 1.5 TR/2.0/3.00TR Capacity including taking out unserviceable Starting Relay from AC complete all as specified and directed.
M&L Strainer with Capillary Tube of AC Window/ Split Type) 1.5 /2.0/3.0 TR Capacity including taking out unserviceable Strainer with Capillary Tube from AC complete all as specified and directed.
M&L Thermostat Switch of AC (Window/Split Type) 1.5 TR/2.0/3.0 TR Capacity including taking out unserviceable Thermostat Switch from AC complete all as specified and directed.
S&F cooling coil suitable for window type room AC 1.5/2 TR including taking out unserviceable cooling coil of capacity 1.5/2 TR. complete all as specified and directed.
S&F Condensing coil suitable for window type AC 1.5/ 2 ton including taking out unserviceable Condensing coil of capacity 1.5/2 ton complete all as specified and directed.
S&F Condensing coil suitable for split type AC including taking out unserviceable Condensing coil of capacity 2 ton complete all as specified and directed.
S&F cooling coil suitable for split type AC including taking out unserviceable cooling coil up to capacity 2 ton complete all as specified and directed.
S&F Indoor unit suitable for 1.5 TR split type AC including taking out unserviceable Indoor unit complete all as specified and directed.
S&F outdoor unit suitable for 1.5 TR split type AC without compressor including taking out unserviceable outdoor unit complete all as specified and directed.
S&F Indoor unit suitable for up to 2 TR split type AC including taking out unserviceable Indoor unit complete all as specified and directed.
S&F outdoor unit suitable for up to 2 TR split type AC without compressor including taking out unserviceable outdoor unit complete all as specified and directed.
S&F in replacement of Hermatically sealed unit compressor for split/ window type AC capacity 1.5 Ton complete all as specified and directed.
All as per ser item No. 60.00 above but of split/ window type AC capacity 2.0 Ton.
Taking down/up defective AC 1.5 TR Capacity (Window/Split Type), Transportation from MES Store Yard/Site to Workshop and Back including re-fixing /re-installing after taking out defective/burnt Compressor Sealed Unit and providing new Compressor Rotary/ Reciprocating as per site requirment of same Capacity from Authorised Dealer including Flushing of Condenser and Charging with required quantity of appropriate Refrigerant Gas R22/R410 including reconnection of electric connections, functioning AC in all respect and Testing, complete all as specified and directed.
All as per Item No. 62.00 above, but AC 2.0 TR Capacity (Window/Split Type).
M&L for PCB with remote for window type AC up to 2 Ton capacity including taking out unserviceable PCB complete all as specified and directed .
M&L for PCB with remote for Split type AC 2/3(1.5x2) Ton capacity including taking out unserviceable PCB complete all as specified and directed .
M&L for PCB & motherboard with remote complete set for Inverter Split type AC up to 2 Ton capacity including taking out unserviceable PCB complete all as specified and directed .
M&L in replacement Remote of AC ( Window/Split Type) 1.5/2.0 TR capacity (As per sample or as per site requirement) complete all as specified and directed.
S&F wiring kit suitable for 1.5 to 2.0 ton capacity AC complete including taking out unserviceable wiring kit complete all as specified and directed.
S&F gas charging pin valve complete including taking out unserviceable pin valve complete all as specified and directed.
Taking out window type AC complete unit from any height/ any floor up to four storey building and shifting to another location in the same or other building in the complex including refixing of the unit complete all as specified and directed.
Taking out split type AC complete indoor and outdoor unit from any height/ any floor up to four storey building by including pumping down the gas into the compressor by controlling the suction and discharge valves , disconnecting the suction and dischagre copper piping and shifting to another locatiion in the same or other building in the complex including refixing of the unit complete all as specified and directed.
S&F in replacement of casing of window type AC including company fitted condensing & cooling coil complete including PCB except compressor complete all as specified and directed.
M&L in replacement of split valve ¼” for split AC up to 2.00 ton capacity complete all as specified and directed.
All as per item ser No. 73.00 above but 1/2".
S&F in replacement compressor shut off valve 3/8" for split AC up to 2.00 ton capacity complete all as specified and directed.
S&F in replacement compressor shut off valve 5/8" for split AC up to 2.00 ton capacity complete all as specified and directed.
S&F in replacement of electrolyte grade copper tubing of size 1/4" suitable for any type of split type AC including synthetic rubber foam complete all as specified and directed. Note : - The quoted rate is inclusive of necessary T&P, Rope, Ladder etc with safety equipment for execution the work upto six stories building complete.
All as per item ser No. 77.00 above but size 1/2".
All as per item ser No. 77.00 above but size 3/8".
All as per item ser No. 77.00 above but size 5/8".
S&F in replacement PVC conduit 20mm dia including all clamps & accessories and connecting the condensate pipe of ACs to this conduit for proper drainout of condensate water from ACs of Bldgs upto 5 (five) storey complete all as specified and directed.
S&F in replacement PVC conduit 25mm dia including all clamps & accessories and connecting the condensate pipe of ACs to this conduit for proper drainout of condensate water from Acs of Bldgs upto 5 (five) storey complete all as specified and directed.
S&F in replacement Hermatically Sealed compressor for 40/80 Ltrs capacity water cooler including bracing the suction and discharge lines complete all as specified and directed.
S&F in replacement Hermatically Sealed compressor for 60/120 Ltrs capacity water cooler including bracing the suction and discharge lines complete all as specified and directed.
S&F in replacement metal plug top 3 pole and earth, 20 Amps, 240 volts suitalbe for sheet metal enslousers complete all as specified and directed.
S&F in repalcement metal enclosures with clad socket & plug top 3 pole and earth, including of MCB SP 25 Amps 240 volts complete all as specified and directed.
S&F in replacement of PVC insulated flexible copper conductor 3 core 1100 volts grade of size 2.50 Sqmm complete all as specified and directed.
S&F in replacement of PVC insulated flexible copper conductor cable 1100 volts grade, 3 core of size 1.5 Sqmm complete all as specified and directed.
M&L in replacement for submain wiring including PVC casing caping 2 run 4.00 Sqmm cable PVC insulated copper conductor multi - stranded as per FRLS cable drawn through conduit pvc 20mm dia mediam duty with all accessories including 4.0 Sqmm single stranded copper conductor cable PVC insulated unsheathed for earth continuity connected to common earth dolly and complete all as specified and directed.
S&F in replacement AC stand suitable for out door AC unit up to capacity of 2 ton with necessary 40x40x6mm angle iron including fixing arrangements like welding, fabrication and nuts & bolts etc upto six stories building complete all as specified and directed.
S&F in replacement reverse valve system made of copper for heating option suitable for 1.5/2.0 ton split / window type AC including appropriate Gas Charging complete all as specified and directed.
M&L for servicing of water cooler of any capacity including cleaning of water cooler from inside and outside with potassium permanganate, servicing of cooling coil, fan, motor, condensor, fan blades and its connected water and refrigerant fittings complete all as specified and directed.
Supply and charging the gas in the water cooler of any make and capacity up to 150 ltr capacity including testing and detecting leakage if any with nitrogen gas and vaccum the system after rectification of all leakages complete all as specifie and directed.
S&F in replacement thermostat switch suitalbe for water cooler of any make & size complete all as specified and directed.
S&F in replacement starting relay/over load relay suitalbe for water cooler of any make & size complete all as specified and directed.
S&F in replacement defective push cock 15 mm bore chromium plated heavy duty suitable for water cooler of any make and capacity complete all as specified and directed.
M&L for preparation of old painted surfaces of water cooler by removing old deteriorated paint, making surfaces smooth and applying two coats of synthetic enamel paint over a coat of red oxide primer by spray painting complete all as specified and directed.
S&F in replacement fan motor ISI marked suitalbe for water cooler as per existing capacity upto 150 ltrs complete all as specified and directed.
S&F in replacement of condenser fan suitable for water cooler upto 150 ltrs capacity complete all as specified and directed.
S&F in replacement 15 mm dia PVC connection of length upto 600mm with PTMT nuts on both ends complete all as specified and directed.
S&F in replacement condenser coil suitable for water cooler upto 150 ltrs capacity complete all as specifed and directed.
S&F in replacement steel/aluminium waste water tray suitable for water cooler upto 150 ltrs capacity complete all as specifed and directed.
M&L for servicing of desert cooler of any size including cleaning of desert cooler from inside & outside, greasing of fan kit, motor, water pump and connected accessories complete all as specified and directed.
M&L for painting of desert cooler capacity upto 4000 Cfm with two coats of approved synthetic enamel paint inside & outside including fan/fan blade/brackets after scrapping the rust,peal of paint and preparation of surface complete all as specified and directed. Note : The rates are inclusive of taking down cooler from any height, removal to workshop for painiting and refixing in position after painting.
S&F in replacement of desert cooler submersible water pump complete with electric motor single phase 230 volts 50Hz including lead, connecting & testing as per sample complete all as specified and directed.
S&F in replacement desert cooler fan motor,copper wound suitable for upto 450mm sweep SP 230 volts 50HZ including legs, rubber bush nuts/bolts for fixing of fan motor complete with connection & testing complete all as specified and directed.
S&F in repalcement of commercial ply wood BWP 4mm thick ISI marked for desert cooler of any size to close the opening between desert cooler grill and window complete all as specified and directed.
S&F in replacement plug top 3 pin 5 Amps complete all as specified and directed.
S&F in replacement plug top 3 pin 15 Amps complete all as specified and directed.
S&F in replacement motor capacitor 2.5/3.15/4 mfd complete all as specified and directed.
S&F in replacement front grill made of MS complete with air guide vanes suitable for desert cooler of capacity 4000 Cfm complete all as specified and directed.
S&F in replacement of body without side panels made out of galvanised iron sheets of 22 gauge for bottom tank & 20 gauge for top cover of desert cooler body duly painted with red-oxide primer & 2 coat of synthetic enameled paint approx size 0.50mx0.50m complete with fixing of all spare complete all as specified and directed.
S&F in replacement of side panels of desert cooler body of 22 gauge of existing size & shape duly painted with red-oxide primer & 2 coat of synthetic enameled paint complete with fixing of all spare approx size 0.40mx0.50m complete all as specified and directed.
S&F in replacement of float valve assembly with PTMT ferrule 15 mm dia and PVC ball valve suitable for water cooler up to 150 ltrs capacity and desert cooler upto 4000 Cfm complete all as specified and directed.
S&F new wood wool pad,(Khus Khas) set of three covered by GI wire mesh suitable for desert cooler including taking out the old unserviceable existing pad complete all as specifed & directed
M&L for replacement of aluminium multi wing Fan blade, best quality as per existing type and size suitable for desert cooler complete all as specifed and directed
Taking down ceiling fan/exhaust/pedestal/table/air circulating fan of any size or make by disconnection eletric connection and removing from site for rewinding/ overhauling/ engrawing of MES No of fans and fixing the same in eixsting position or as directed with eletric connection and testing complete all as specified and directed
M&L for overhauling of ceiling fan/pedestal/exhaust/table/air circulating fan of any size or make opening the fan motor, overhauling by removing dust from field coils including varnishing of field coils and greasing from motor with superior qauality grease for smooth running inlcuding cleaning and washing the blades and assembling of fan motor and refixing at the same place complete all as specified and directed.
M&L for removing of burnt out winding wire from ceiling fan of any make of size 1200/1400 mm sweep including cleaning of slots etc and rewinding with super enameled copper winding wire as per existing size/gauge including insulating material and varnishing complete all as specified and directed.
All all as per item Ser No 120.00 above but for exhaust fans of size 225 mm sweep to 380 mm sweep
All all as per item Ser No 120.00 above but for exhaust fan of size 450 mm sweep
All all as per item Ser No 120.00 above but for pedestal fan/Air circulator fan of size 400 mm to 600 mm sweep.
All all as per item Ser No 120.00 above but for table fan/wall mounted of 400 mm sweep
M & L for replacement of defective ball bearing for ceilng/table/pedestal/Air-circulators fan of any size complete all as specified and directed.
All as per item Ser No 125.00 above but for exhaust fan upto 450mm size.
M&L for replacement of rubber seal of suitable size for ceiling fan complete all as specified and directed
M&L for replacement of gun metal bush suitable for any type/model/size of fans complete all as specified and directed.
M&L for replacement of ceiling fan regulator five step 60/120 watt electronic type AC 230/240 Volts suitable for 1200/1400 mm sweep complete with all fixing accessories including necessary electric connection all as specified and directed.
M&L for painting of ceiling fans any make and size at site with one coat of superior quality synthetic enameled paint of approved make & colour by spraying after filling cavities with filler and preparation of surface including marking (MES No......) with black synthetic enamel paint complete all as specified and directed.
All as per item Ser No 130.00 above but exhaust fan of size 250/300 mm sweep.
All as per item Ser No 130.00 avove but for exhaust fan of size 450 mm sweep
S&F in replacement voltage stabilizer 4 KVA suitable for window/split type AC of capacity upto 1.5 TR working on AC 240 V,50Hz single phase complete all as specified and directed.
S&F in replacement voltage stabilizer 5 KVA suitable for window/split type AC of capacity upto 2 TR working on AC 240 V,50Hz single phase complete all as specified and directed.
S&F in replacement Pedestal fan 450mm sweep working on AC 240 V,50Hz, single phase complete all as specified and directed. Note: Old unserviceable fan shall bedeposited to E/M store yard.
S&F in replacement exhaust fan PVC body 250mm sweep working on AC 240 V,50Hz, single phase complete all as specified and directed. Note: Old unserviceable fan shall bedeposited to E/M store yard.
Taking down geyser of capacity 25 ltrs after dissconnecting the water and electric connections etc and replace the stainless steel tank with assembly to make the geyser fully functional and refixing the same at its orignal position complete all as specified and directed.
All as per item ser No. 137.00 above but capacity 50 ltrs.
S&F in replacement of Heating element triangle/round type as existing of capacity 1.5KW of Hot appliances complete all as specified and directed. .
All as per item ser No. 139.00 above but capacity 2KW.
S&F in replacement of thermostate as per existing of capacity 25/50 ltrs of Hot appliances complete all as specified and directed. .
S&F in replacement of shut off valve as existing of capacity 25/50 ltrs of Hot appliances complete all as specified and directed. .
Taking out the diffective PCB & mother board with remote complete set from 'inverter split type AC upto 2 Ton capacity and repair the deffective PCB with mother board and remote and fixed the same in its original position complete all as specified and directed.
S&F in replacement of Thermo insulation glass wool as per existing of capacity 25/50 ltrs of Hot appliances complete all as specified and directed.
S&F in replacement of water connection CP for inlet & outlet (Hot & Cold) as existing of capacity 25/50 ltrs of Hot appliances complete all as specified and directed.
S&F in repair switch piano type 5 A SP one way complete all as specified and directed.
S&F in repair switch piano type 5 A SP two way complete all as specified and directed.
S&F in repair bell push piano type 5 A complete all as specified and directed.
S&F in repair socket outlet 5 pin 5 A flush type complete all as specified and directed.
S&F in repair of Switch socket combination 2 in 1, 3 pin, 5 and 15 amp flush type universal complete all as specified and directed.
S&F in repair of Ceiling fan regulator electronic, step type, 120 watts 2 module complete all as specified and directed.
S&F in repair of bell ding Dong AC 230 vols, single pole complete all as specified and directed.
S&F in repair of thermostat cut off cut in range 0-75 degree centigrade AC 230 V suitable for storage type geyser 25 ltr capacity complete all as specified and directed..
S&F in repair of thermostat cut off cut in range 0-75 degree centigrade AC 230 V suitable for storage type geyser 50 ltr capacity complete all as specified and directed..
S&F in repair of white hylam sheet of size 10" x 8" x 2 mm thickness including nut and washer fixing on wall complete all as specified and directed.
S&F in repair of white hylam sheet of size 6" x 4 " x 2 mm thickness including nut and washer fixing on wall complete all as specified and directed.
S&F in repair of PVC rectangular block for mounting, switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover of size 100 mm x 100 mm and 50 mm deep complete all as specified and directed.
S&F in repair of white cover plate with frame 2 module complete all as specified and directed.
S&F in repair of white cover plate with frame 4 module complete all as specified and directed.
S&F in repair of modular metal flush box 2 module complete all as specified and directed.
S&F in repair of modular metal flush box 4 module complete all as specified and directed.
Note for item No 29 to 161 :- 1. The contractor's site supevisor/site engineer shall be report at 0900 hrs daily excluding Sunday & holiday to collect the complaints/job card & complete the same complaint provided by JE E/M within 48 hours 2. If the complaints are not attended within stipulated time period, contractor shall be liable for recovery as follows: - (a) After 48 Hrs, Rs - 1000.00 Per complaint per day. 3. The technicians for repair of summer appliances can be called during non-working days/hrs (i.e. Sunday, Holidays & after working hrs) for any vital complaint at DRDO area. 4. The contractor has to produce job card duly signed by user & JE E/M to Engineer-in-charge.
Cleaning of outdoor units of 22TR outdoor unit with soft chemical and corrasion protection with Nanova care coat of ACX-4000 ultracorr or equivalent complete all as specified and directed.
Cleaning of cooper pipe of different sizes upto 40mm dia and corrasion protection with Nanova care coat of ACX-4000 ultracorr or equivalent complete all as specified and directed.
HONEY COLLECTION
Pradeep Bros
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .