Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.4 LAccepted-AOC ANAND NAGAR KAMRE RATU ROAD DIST RANCHI JHARKHAND | RANCHI | RANCHI | JHARKHAND | 835222 | L1 | Accepted-AOC The L1 bidder is techno-commercially eligible and the rate quoted is reasonable and justified, which has been accepted by the Competent Authority, NK Area. | |
| 2 | L2₹10.5 L+₹5,769 (0.55%)Rejected-Finance ANAND NAGAR KAMRE RATU ROAD DIST RANCHI JHARKHAND | RANCHI | RANCHI | JHARKHAND | 835222 | L2 | Rejected-Finance L2 | |
| 3 | L3₹11.4 L+₹87,319 (8.33%)Rejected-Finance 00 C O LAKHAN LAL AGRAWAL RATU ROAD NEAR KABLISTHAN RANCHI JHARKHAND 834001 | RANCHI | JHARKHAND | 834001 | L3 | Rejected-Finance L3 |
Tender Value
₹11.3 L
EMD Value
₹14,200
Closing Date
30 May 2024, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SO EnM NK
GM OFFICE, NK AREA
Re-arrangement of 33kV Overhead Lines, Feeder No. 05 and 11kV Overhead line supplying power to Rohini and Purnadih for removal of hindrances to the ongoing 7.5 MTY CHP-Silo Construction work under KDH OCP, NK Area
2024_CCL_309015_1
GM (NK)/EnM/e-NIT/2024-25/ 47
Open Tender
Electrical and Maintenance Works
Item Rate
11 days
KDH OCP, NK Area
As per NIT
2 documents required · 2 mandatory
₹14,200
16 Jul 2024
25 May 2024
31 May 2024
25 May 2024
30 May 2024
25 May 2024
25 May 2024 - 27 May 2024
Amount
Part-A: Re-arrangement of 33kV Feeder No. 05 near workshop
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 11 Mtr and upto 13 Mtr
Erection of ACSR conductor of 7/3.35 mm to 7/4.00 diameter and above including binding etc. as required
Supplying and erection of galvanised stay set for 33 KV over head lines complete with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stay clamps, turn buckle ( 20 mm X 600 mm ), 7/ 4.00 mm dia G.I. stay wire and 33 KV strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required
Supplying and erection of a set of three 11 KV disc insulator for 33 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required
Supplying and erection of 33 KV 90 KN pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required
Supplying of two lengths of channel iron 100 mm X 50 mm X 6 mm (9.56 kg per metre) double pole cross arm for three wire 33 KV over head line conductors complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm M.S. flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arms together, including drilling holes for insulator pins/ fittings, bolts, nuts, washers etc and painting with primer and finish paint as required.
Erection of double pole 3 wire cross arm for 11KV/ 22KV/ 33 KV over head lines as required
Supplying and erection of a set of cross bracing frame work for 11 KV over head line double pole structure having four members fabricated out of 50 mm X 50 mm X 6 mm angle iron to form a rectangle of minimum size 1400 mm width X 2500 mm height complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, and nuts etc (as per drawing) and painting with primer and finish paint as required
Supply and erection of 65mm x 6 mm MS flat iron clamps and wedges, bolts and nuts including drilling and painting with primer and finish paint as required.
Providing and fixing of anti climbing arrangement for electric poles with GI barbed wire of 9.38 kg per 100 Mtr (aluminum) with grease and GI staples at both end 30 Mtr barbed wire for each pole.
Supply of 7/16 SWG GI wire for erection of cradle guards
Supply of 8 SWG GI wire for ring in cradle guards
Erection of 7/16 SWG G.I wire for cradle guards
Erection of cradle guard as required
Providing and fixing of mild steel hooks (I hook)
Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required
Dismantling of over head lines comprising of copper/ aluminium over head conductor, G.I. wire, cross arms, insulators etc. as required
Part-B: Re-arrangement of 11kV Overhead line diversion of Purnadih OCP and Rohini OCP near workshopFeeder No. 05 near workshop
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 11 Mtr and upto 13 Mtr
Erection of all aluminium conductor of 7/1.96 mm to 7/3.10 mm diameter including binding etc. as required.
Supplying and erection of stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, bow tightener, 7/ 3.15 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.
Supplying and erection of 11 KV 90 KN disc insulator for 11 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required
Supplying and erection of 11 KV 90 KN pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required 90 KN
Supplying of two lengths of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) double pole cross arm for three wire 11KV over head line conductors complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm M.S. flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arms together, including drilling holes for insulator pins/ fittings, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required.
Erection of double pole 3 wire cross arm for 11KV/ 22KV/ 33 KV over head lines as required
Supplying and erection of a set of cross bracing frame work for 11 KV over head line double pole structure having four members fabricated out of 50 mm X 50 mm X 6 mm angle iron to form a rectangle of minimum size 1400 mm width X 2500 mm height, complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts and nuts etc (as per drawing) and painting with primer and finish paint as required.
Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required
Dismantling of over head lines comprising of copper/ aluminium over head conductor, G.I. wire, cross arms, insulators etc. as required
Total impact of GST for the purpose of CTC
M/S A. K. ENTERPRISES
M/S PRAVEEN KUMAR
techsummary_320205.pdf
PDF • 0.23 MB
finsummary_320205.pdf
PDF • 0.94 MB
AOC_47_0001.pdf
PDF • 3.14 MB
BOQ Comparative Chart
xlsx • 0.01 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .