Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.3 CrAccepted-AOC | ₹1.3 Cr | 1 | Accepted-AOC Accepted |
| 2 | Not Admitted-Fee/PreQual/Technical C O SARAT KALITA SONDHA P O NALBARI P S NALBARI DIST NALBARI ASSAM PIN 781335 | NALBARI | ASSAM | 781335 | - | - | Not Admitted-Fee/PreQual/Technical Others-Hard copy not submitted |
Tender Value
₹1.3 Cr
EMD Value
₹2.6 L
Closing Date
13 Feb 2024, 2:00 pmClosed
Chief Engineer, PWD(Roads), Assam
O/o the Chief Engineer, PWD(Roads), Assam
Re-construction of I) PWD (Roads) Chief Engineer Office Complex Road with L/B Drain, II) Kannachal Byelane No-1 Rd construct of L/B Drain, III) Red Cross Hospital Road under Mukhya Mantrir Paki Path Nirman Achani for the year 2023-24
2024_PWD_36055_5
MMPPNA-Guwahati-5Works(RB)
Open Tender
Civil Works – Roads
Item Rate
90 days
Guwahati
Please refer Tender documents.
4 documents required · 4 mandatory
₹2,700
₹2.6 L
Yes
16 Apr 2024
8 Feb 2024
13 Feb 2024
8 Feb 2024
13 Feb 2024
8 Feb 2024
8 Feb 2024 - 13 Feb 2024
Amount
Re-construction of (I) PWD (Roads) Chief Engineer Office Complex Road including construction of Load Bearing Drain (Ch. 0.00m to Ch. 170.00m) : 'By Mix in Place Method (Construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density,complete as per cl. 401
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405 (Rate as per analysis)
Providing and laying interlocking concrete block pavement with M40 grade grade of concrete blocks having thickness 80mm as per technical specification clause 1504 complete including carriage. b) Excluding Edge block/ Edge restraints
RCC Load Bearing Drain: Earth work in excavation of foundation of structures as per drawing and technical specification300, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material including all lifts and leads and as directed by engineer in all types of soil except hard rock(where requires blasting.) I. Ordinary Soil,i) Upto 3m depth
Removal of unsuitable soil including excavation, loading and disposal upto 1000 m lead but excluding compaction ground supporting embankment subgrade replacement by suitable soil, which shall be paid separately as per Clause 303.5.2 as per Technical Specification Clause 302.3.11
Providing and laying of dry rubble flooring complete as per drawings and technical specifications Clause 1303.3
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803,1202 & 1203, PCC Grade M15.Nominal mix 1:2.5:5 (With crushed Stone)
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX or equivalent)) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 120
Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. (E) RCC Grade M20 (a) Height up to 5m
Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specification.
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification. (B) Sandy materials
Maintenance work 1st year Routine Maintenance (Rate to be quoted at Column 13 by bidder should be same as mentioned at Column 6)
2nd year Routine Maintenance (Rate to be quoted at Column 13 by bidder should be same as mentioned at Column 6)
3rd year Routine Maintenance (Rate to be quoted at Column 13 by bidder should be same as mentioned at Column 6)
4th year Routine Maintenance (Rate to be quoted at Column 13 by bidder should be same as mentioned at Column 6)
Re-construction of (II) Kannachal Byelane No-1 Road including construction of Load Bearing Drain) : Dismantling of cement concrete pavements by mechanical means using pneumatic tools breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials upto a lead of 1000 m, stacking serviceable and unserviceable materials separately
Removal of unsuitable soil including excavation, loading and disposal upto 1000 m lead but excluding compaction ground supporting embankment subgrade replacement by suitable soil, which shall be paid separately as per Clause 303.5.2 as per Technical Specification Clause 302.3.11
By Mix in Place Method (Construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density,complete as per cl. 401
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405 (Rate as per analysis)
Providing and laying interlocking concrete block pavement with M40 grade grade of concrete blocks having thickness 80mm as per technical specification clause 1504 complete including carriage. Including Edge block/ Edge restraints
Providing,fitting and erecting pre fabricated railing of STRUCTURA materials having size of 2.00x0.90M in panels made of 25x25x2.6/40x40x2.6 vertical bars and .40x40x2.6/32x32x2.6 horizontal bars.The two end posts of each panel are founded with M-15 cement concrete up to a depth of 200mm with anti corrosive primer and paint etc. complete as per approved drawing and technical specification as directed..
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801. (ii) 600mm equilateral triangle
RCC Load Bearing Drain: Earth work in excavation of foundation of structures as per drawing and technical specification300, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material including all lifts and leads and as directed by engineer in all types of soil except hard rock(where requires blasting.) I. Ordinary Soil,i) Upto 3m depth
Removal of unsuitable soil including excavation, loading and disposal upto 1000 m lead but excluding compaction ground supporting embankment subgrade replacement by suitable soil, which shall be paid separately as per Clause 303.5.2 as per Technical Specification Clause 302.3.11
Providing and laying of dry rubble flooring complete as per drawings and technical specifications Clause 1303.3
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803,1202 & 1203, PCC Grade M15.Nominal mix 1:2.5:5 (With crushed Stone)
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX or equivalent)) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 120
Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. (E) RCC Grade M20 (a) Height up to 5m
Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specification.
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification. (B) Sandy materials
Road Side Stone Masonry Guard Wall: : Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material I. Ordinary Soil,i) Upto 3m depth
Providing and laying of dry rubble flooring complete as per drawings and technical specifications Clause 1303.3
Providing concrete for plain/reinforced concrete in open foundationscomplete as per drawings and technical specifications Clause 802, 803, 1202 & 1203. A) With crushed Stone P.C.C grade M 10. Nominal mix 1:3:6
Stone masonry in cement mortar for substructure complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204. III) Random rubble masonry in 1:4 cement mortar
Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specification.
Plastering with cement mortar (1:4), 15 mm thick on brickwork in substructure as per technical specification Clauses 613.4 & 1204
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification. (B) Sandy materials
Maintenance work 1st year Routine Maintenance (Rate to be quoted at Column 13 by bidder should be same as mentioned at Column 6)
2nd year Routine Maintenance (Rate to be quoted at Column 13 by bidder should be same as mentioned at Column 6)
3rd year Routine Maintenance (Rate to be quoted at Column 13 by bidder should be same as mentioned at Column 6)
4th year Routine Maintenance (Rate to be quoted at Column 13 by bidder should be same as mentioned at Column 6)
Re-construction of (III) Red Cross Hospital Road providing WBM Grade-II & III, ICBP including construction of Load Bearing Drain : Dismantling of cement concrete pavements by mechanical means using pneumatic tools breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials upto a lead of 1000 m, stacking serviceable and unserviceable materials separately
Removal of unsuitable soil including excavation, loading and disposal upto 1000 m lead but excluding compaction ground supporting embankment subgrade replacement by suitable soil, which shall be paid separately as per Clause 303.5.2 as per Technical Specification Clause 302.3.11
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification. (B) Sandy materials
By Mix in Place Method (Construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density,complete as per cl. 401
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 2 as per Technical Specification Clause 405 (Rate as per analysis)
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405 (Rate as per analysis)
Providing and laying interlocking concrete block pavement with M40 grade grade of concrete blocks having thickness 80mm as per technical specification clause 1504 complete including carriage. Excluding Edge block/ Edge restraints
Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes and conforming to the MoSrt&H specifications
Providing reflective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H’s fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance.
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801. (ii) 600mm equilateral triangle
RCC Load Bearing Drain: Earth work in excavation of foundation of structures as per drawing and technical specification300, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material including all lifts and leads and as directed by engineer in all types of soil except hard rock(where requires blasting.) I. Ordinary Soil,i) Upto 3m depth
Removal of unsuitable soil including excavation, loading and disposal upto 1000 m lead but excluding compaction ground supporting embankment subgrade replacement by suitable soil, which shall be paid separately as per Clause 303.5.2 as per Technical Specification Clause 302.3.11
Providing and laying of dry rubble flooring complete as per drawings and technical specifications Clause 1303.3
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803,1202 & 1203, PCC Grade M15.Nominal mix 1:2.5:5 (With crushed Stone)
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX or equivalent)) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 120
Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. (E) RCC Grade M20 (a) Height up to 5m
Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specification.
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification. (B) Sandy materials
Maintenance work 1st year Routine Maintenance (Rate to be quoted at Column 13 by bidder should be same as mentioned at Column 6)
2nd year Routine Maintenance (Rate to be quoted at Column 13 by bidder should be same as mentioned at Column 6)
3rd year Routine Maintenance (Rate to be quoted at Column 13 by bidder should be same as mentioned at Column 6)
4th year Routine Maintenance (Rate to be quoted at Column 13 by bidder should be same as mentioned at Column 6)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .