Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAdmitted-Finance | ₹1.1 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.2 Cr+₹7.0 L (6.15%)Admitted-Finance | ₹1.2 Cr+₹7.0 L (6.15%) | L2 | Admitted-Finance |
| 3 | L3₹1.3 Cr+₹11.0 L (9.59%)Admitted-Finance 90 4TH CROSS 14TH BLOCK NAGARBHAVI 2ND STAGE BENGALURU 560 072 | BENGALURU URBAN | KARNATAKA | 560072 | ₹1.3 Cr+₹11.0 L (9.59%) | L3 | Admitted-Finance |
| 4 | L4₹1.3 Cr+₹13.7 L (12.0%)Admitted-Finance NO 43 MARUTHI TOWER 4TH CROSS SAMPIGE ROAD MALLESHWARAM BANGALORE URBAN BANGALORE KARNATAKA 560003 | BENGALURU URBAN | KARNATAKA | 560003 | ₹1.3 Cr+₹13.7 L (12.0%) | L4 | Admitted-Finance |
| 5 | L5₹1.3 Cr+₹18.8 L (16.4%)Admitted-Finance | ₹1.3 Cr+₹18.8 L (16.4%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | R K Associates L1 | shanti enterprises electricals pvt ltd L2 | Polyphase Engineering Pvt Ltd L3 | Maverik Facility Management PVt. Ltd. L4 | classic eletricals and egineers L5 | KATAKAM INFRA PROJECTS INDIA PRIVATE LIMITED L6 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Substation- 1: Supply, Installation, Testing and Commissioning of 12Kv, 21kA, SF6 Insulated 4- Way extensible Compact ring main unit (RMU) comprising
(a) 2 Nos of Manual / Motorized (24V DC) operated Vacuum circuit breaker of 630A as EB supply loop in/ loop out with integral earth switch, with live cable indicators, with self powered over current & earth fault relay With RS-485 communication port, with shunt trip coil of 230v AC, with manual push buttons for closing/Tripping, with CTs for metering, with potential free contacts Breaker & Earth switch ON/OFF, With Local / remote switch, GE relay (IEC 61850 Protocol)
(b) 2 Nos of Manual / Motorized (24V DC) operated Vacuum circuit breaker of 630A as outgoing to Transformer with integral earth switch, with live cable indicators, with self powered over current & earth fault relay With RS485 communication port, with shunt trip coil of 230v AC, with manual push buttons for closing/Tripping, with CTs for metering, with potential free contacts Breaker & Earth switch ON/OFF, GE relay (IEC 61850 Protocol)
(c) Metering module comprising Potential transformer of 11kV/v3/110V/v3,50VA, CL 0.5, With R-Y-B Lamps , with space heater & thermostat, With space for RTU Unit, with multifunction meter, with Auxiliary transformer
(d) With mimic diagram, with padlocking facility & with IP67 degree of protection for SF6 Tank, with 2x12V DC,12AH Battery& Charger
Make : Schneider / Siemens/ Eaton | 1 | Job | - | - | - | - | - | - |
| 2.00 | Providing Civil Foundation for RMU with necessary concrete, size stones, angles / Channels and plastering works complete in all respects as per OEM Fondation Specification & Drawings. | 1 | Job | - | - | - | - | - | - |
| 3.00 | Supply, Installation, Testing & Commissioning of of 750KVA, 11KV/433V, Oil cooled Transformer with OCTC as per IS-1180 as per detailed specification enclosed.
(Make :Universal/Voltamp/Kirloskar) | 1 | Job | - | - | - | - | - | - |
| 4.00 | Providing Civil Foundation for 750 KVA Transformer with necessary concrete, size stones, angles / Channels and plastering works complete as per OEM Foundation drawings. | 1 | Job | - | - | - | - | - | - |
| 5.00 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipewith cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. | 4 | set | - | - | - | - | - | - |
| 6.00 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) | 70 | Mtr | - | - | - | - | - | - |
| 7.00 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) | 70 | Mtr | - | - | - | - | - | - |
| 8.00 | Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required. | 1 | Mtr | - | - | - | - | - | - |
| 9.00 | Supplying and laying of high tension 11KV cable, Dry Curing & Dry Cooling with true triple extrusion, simultaneously through a single common head, 3 core under ground XLPE (E) cable having stranded compact circular aluminium conductor, screened insulated, insulation screened with extruded semiconducting compound in combination with copper tape, core laid up extruded inner sheathed of GI flat strip armoured and overall PVC sheathed with specified IS 7098/11/85 with latest amendments & confirming - 3Cx95 sqmm | 30 | Mtr | - | - | - | - | - | - |
| 10.00 | Supplying and making outdoor cable end jointing with cast resin compound, including lugs and other jointing materials, for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required - 3 Core x 95/120sqmm | 2 | Each | - | - | - | - | - | - |
Tender Value
₹1.4 Cr
EMD Value
₹2.1 L
Closing Date
4 Jul 2020, 6:00 pmClosed
The Registrar
IISc, Bangalore
Upgradation of Substation SS-1, SS-4 and SS-13 to SCADA controlled Smart Substations in IISc, Bangalore
2020_IISC_562095_1
IISc/Tender 3/2020-21
Open Tender
Electrical Works
Works
120 days
IISc, Bangalore
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
The Registrar, IISC
₹2.1 L
Through On Line
27 Jul 2020
1 Jun 2020
6 Jul 2020
1 Jun 2020
4 Jul 2020
12 Jun 2020
9 Jun 2020
Amount
Substation- 1: Supply, Installation, Testing and Commissioning of 12Kv, 21kA, SF6 Insulated 4- Way extensible Compact ring main unit (RMU) comprising (a) 2 Nos of Manual / Motorized (24V DC) operated Vacuum circuit breaker of 630A as EB supply loop in/ loop out with integral earth switch, with live cable indicators, with self powered over current & earth fault relay With RS-485 communication port, with shunt trip coil of 230v AC, with manual push buttons for closing/Tripping, with CTs for metering, with potential free contacts Breaker & Earth switch ON/OFF, With Local / remote switch, GE relay (IEC 61850 Protocol) (b) 2 Nos of Manual / Motorized (24V DC) operated Vacuum circuit breaker of 630A as outgoing to Transformer with integral earth switch, with live cable indicators, with self powered over current & earth fault relay With RS485 communication port, with shunt trip coil of 230v AC, with manual push buttons for closing/Tripping, with CTs for metering, with potential free contacts Breaker & Earth switch ON/OFF, GE relay (IEC 61850 Protocol) (c) Metering module comprising Potential transformer of 11kV/v3/110V/v3,50VA, CL 0.5, With R-Y-B Lamps , with space heater & thermostat, With space for RTU Unit, with multifunction meter, with Auxiliary transformer (d) With mimic diagram, with padlocking facility & with IP67 degree of protection for SF6 Tank, with 2x12V DC,12AH Battery& Charger Make : Schneider / Siemens/ Eaton
Providing Civil Foundation for RMU with necessary concrete, size stones, angles / Channels and plastering works complete in all respects as per OEM Fondation Specification & Drawings.
Supply, Installation, Testing & Commissioning of of 750KVA, 11KV/433V, Oil cooled Transformer with OCTC as per IS-1180 as per detailed specification enclosed. (Make :Universal/Voltamp/Kirloskar)
Providing Civil Foundation for 750 KVA Transformer with necessary concrete, size stones, angles / Channels and plastering works complete as per OEM Foundation drawings.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipewith cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required.
Supplying and laying of high tension 11KV cable, Dry Curing & Dry Cooling with true triple extrusion, simultaneously through a single common head, 3 core under ground XLPE (E) cable having stranded compact circular aluminium conductor, screened insulated, insulation screened with extruded semiconducting compound in combination with copper tape, core laid up extruded inner sheathed of GI flat strip armoured and overall PVC sheathed with specified IS 7098/11/85 with latest amendments & confirming - 3Cx95 sqmm
Supplying and making outdoor cable end jointing with cast resin compound, including lugs and other jointing materials, for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required - 3 Core x 95/120sqmm
Supplying of 1.1 KV LT UG cable having aluminum conductor PVC insulated, extruded inner sheathed, galvanized, steel strip (except 2CX10Sq.mm wire armoured) confirming to IS-3975:1990 (No. of Strip indicated in GTP) & extruded PVC outer sheathed armoured cable with specified IS-1554 Part-1:1988 & confirming to GTP - 3.5 core 300 sqmm
Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as required.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required - 3.5 core 300 sqmm (70mm)
Painting of metal fence with 2 Coats of Red oxide & 2 coats of enamel paint of approved shade as required.
Supplying and fixing of the following Safety Equipments: a) Shock treatment chart laminated (Kannada, Engilsh and Hindi) on 8mm Thick wooden board (24''x36'')
b) Rubber mat suitable upto 3.3 KV of 2 mm thick, Class-A with 1 Mtr wide (Electromat make)
c) First aid kit with ABS plastic body, portable, transparent, wall mounting with contents
d) ISI marked 4.5 Kg capacity CO2 Fire Extinguisher with bracket etc.,
e) Fire buckets with Stand filled with sand and water with roof top cover.Make: excellent
f) 415V Danger board as per the regulations with local language (8''x8'')
g) Providing and fixing single line diagram of electrical network printed on A0 size photo paper framed with sandwitched fibre glass frame
h) Supply of 11kV Hand gloves
Substation- 4: Supply, Installation, Testing and Commissioning of 12Kv, 21kA, SF6 Insulated 4- Way extensible Compact ring main unit (RMU)comprising (a) 2 Nos of Manual / Motorized (24V DC) operated Vacuum circuit breaker of 630A as EB supply loop in/ loop out with integral earth switch, with live cable indicators, with self powered over current & earth fault relay With RS-485 communication port, with shunt trip coil of 230v AC, with manual push buttons for closing/Tripping, with CTs for metering, with potential free contacts Breaker & Earth switch ON/OFF, With Local / remote switch, GE relay (IEC 61850 Protocol) (b) 2 Nos of Manual / Motorized (24V DC) operated Vacuum circuit breaker of 630A as outgoing to Transformer with integral earth switch, with live cable indicators, with self powered over current & earth fault relay With RS485 communication port, with shunt trip coil of 230v AC, with manual push buttons for closing/Tripping, with CTs for metering, with potential free contacts Breaker & Earth switch ON/OFF, GE relay (IEC 61850 Protocol) (c) Metering module comprising Potential transformer of 11kV/v3/110V/v3,50VA, CL 0.5, With R-Y-B Lamps , with space heater & thermostat, With space for RTU Unit, with multifunction meter, with Auxiliary transformer (d) With mimic diagram, with padlocking facility & with IP67 degree of protection for SF6 Tank, with 2x12V DC,12AH Battery& Charger Make : Schneider / Siemens/ Eaton
Providing Civil Foundation for RMU with necessary concrete, size stones, angles / Channels and plastering works complete in all respects as per OEM Fondation Specification & Drawings.
Supply, Installation, Testing & Commissioning of of 500KVA, 11KV/433V, Oil cooled Transformer with OCTC as per IS-1180 as per detailed specification enclosed. (Make :Universal/Voltamp/Kirloskar)
Providing Civil Foundation for 500 KVA Transformer with necessary concrete, size stones, angles / Channels and plastering works complete as per OEM Foundation drawings.
Dismantling of existing 11 kV Four Pole MS structure, 2 NosTransformer and 1 No RMU with Accessories.(as a service against buy back)
Servicing of LT Panel - Scope includes complete testing of the LT Kiosk, breakers , bus bars, CTs, meters, contactors and all the protecton relays. Test reports to be submitted on completion of testing. Reconditioning of the panels with complete cleaning inside /outside the panel and painting the rusted areas. Paint shade shall be matching the existing panel colour.
Earthing with copper earth plate 600 mm X 600 mm X 3 mmthick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipewith cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required.
Supplying and laying of high tension 11KV cable, Dry Curing & Dry Cooling with true triple extrusion, simultaneously through a single common head, 3 core under ground XLPE (E) cable having stranded compact circular aluminium conductor, screened insulated, insulation screened with extruded semiconducting compound in combination with copper tape, core laid up extruded inner sheathed of GI flat strip armoured and overall PVC sheathed with specified IS 7098/11/85 with latest amendments & confirming - 3Cx95 sqmm
Supplying and making outdoor cable end jointing with cast resin compound, including lugs and other jointing materials, for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required - 3Cx95/120sqmm
Supplying of 1.1 KV LT UG cable having aluminum conductor PVC insulated, extruded inner sheathed, galvanized, steel strip (except 2CX10Sq.mm wire armoured) confirming to IS-3975:1990 (No. of Strip indicated in GTP) & extruded PVC outer sheathed armoured cable with specified IS-1554 Part-1:1988 & confirming to GTP - 3.5 core 240 sqmm
Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as required.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required - 3½ X 240 sq. mm (62mm)
Painting of metal fence with 2 Coats of Red oxide & 2 coats of enamel paint of approved shade as required.
Supplying and fixing of the following Safety Equipments: a) Shock treatment chart laminated (Kannada, Engilsh and Hindi) on 8mm Thick wooden board (24''x36'')
b) Rubber mat suitable upto 3.3 KV of 2 mm thick, Class-A with 1 Mtr wide (Electromat make)
c) First aid kit with ABS plastic body, portable, transparent, wall mounting with contents
d) ISI marked 4.5 Kg capacity CO2 Fire Extinguisher with bracket etc.,
e) Fire buckets with Stand filled with sand and water with roof top cover.Make: excellent
f) 415V Danger board as per the regulations with local language (8''x8'')
g) Providing and fixing single line diagram of electrical network printed on A0 size photo paper framed with sandwitched fibre glass frame
h) Supply of 11kV Hand gloves
Substation- 13: (Description incomplete, refer Tender document) SUPPLY, INSTALLATION,TESTING AND COMMISSIONING OF 500 KVA, 11KV/433V OUTDOOR COMPACT SUB-STATION WITH OIL FILLED TRANSFORMER WITH OCTC, ACB & MCCB WITH THE FOLLOWING ITEMS /COMPONENTS RMU : 12Kv, 21kA, SF6 Insulated 3- Way Non extensible Compact ring main unit comprising (a) 2 Nos of Manual / Motorized (24V DC) operated Vacuum circuit breaker of 630A as EB supply loop in/ loop out with integral earth switch, with live cable indicators, with self powered over current & earth fault relay With RS-485 communication port, with shunt trip coil of 230v AC, with manual push buttons for closing/Tripping, with CTs for metering, with potential free contacts Breaker & Earth switch ON/OFF, With Local / remote switch, GE relay (IEC 61850 Protocol) (b) 1 No of Manual / Motorized (24V DC) operated Vacuum circuit breaker of 630A as outgoing to Transformer with integral earth switch, with live cable indicators, with self powered over current & earth fault relay With RS485 communication port, with shunt trip coil of 230v AC, with manual push buttons for closing/Tripping, with CTs for metering, with potential free contacts Breaker & Earth switch ON/OFF, GE relay (IEC 61850 Protocol) (c) Metering module comprising Potential transformer of 11kV/v3/110V/v3,50VA, CL 0.5, With R-Y-B Lamps , with space heater & thermostat, With space for RTU Unit, with multifunction meter, with Auxiliary transformer (d) With mimic diagram, with padlocking facility & with IP67 degree of protection for SF6 Tank, with 2x12V DC,12AH Battery& Charger Make : Schneider / Siemens/ Eaton Transformer : 11kV/433V, 500KVA, 3 Phase, 50Hz, Oil filled type, DYN11, Air natural and Oil cooled, Copper wound, With Off Circuit Tap switch, Tap range +5.0 to –10.0% in steps of 2.5%, With Oil & Winding temperature indicator with contacts for Alarm / Trip, With PRV with contacts, With losses as per IS:1180, Level 3 and Impedance of 4.5%, (Make :Universal/Voltamp/Kirloskar) LT Panel : 1) 800A, EDO ACB, 4 Poles, Manual Fixed, 50 KA, microprocessor based release for O/L, S/C, E/F protection with MP based LSIG release with following Accessories: (Make: Schneider / Siemens / L&T) - 1 No. a) Motor Mechanism: 230V AC b) Closing Coil: 230V AC ... ET All
Civil Foundation for CSS with necessary conctere, size stones, angles / Channels and plastering works complete in all respects as per OEM Fondation Specification & Drawings
Dismantling of existing 11 kV Four Pole MS structure and 2 NosTransformers (as a service against buy back)
Servicing of LT Panel - Scope includes complete testing of the LT Kiosk, breakers, bus bars, CTs, meters, contactors and all the protecton relays. Test reports to be submitted on completion of testing. Reconditioning of the panels with complete cleaning inside /outside the panel and painting the rusted areas. Paint shade shall be matching the existing panel color.
Earthing with copper earth plate 600 mm X 600 mm X 3 mmthick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipewith cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required.
Supplying and laying of high tension 11KV cable, Dry Curing & Dry Cooling with true triple extrusion, simultaneously through a single common head, 3 core under ground XLPE (E) cable having stranded compact circular aluminium conductor, screened insulated, insulation screened with extruded semiconducting compound in combination with copper tape, core laid up extruded inner sheathed of GI flat strip armoured and overall PVC sheathed with specified IS 7098/11/85 with latest amendments & confirming - 3Cx95 sqmm
Supplying and making outdoor cable end jointing with cast resin compound, including lugs and other jointing materials, for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required - 3Cx95/120sqmm
Supplying of 1.1 KV LT UG cable having aluminum conductor PVC insulated, extruded inner sheathed, galvanized, steel strip (except 2CX10Sq.mm wire armoured) confirming to IS-3975:1990 (No. of Strip indicated in GTP) & extruded PVC outer sheathed armoured cable with specified IS-1554 Part-1:1988 & confirming to GTP - 3.5 core 300 sqmm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size (Above 185 sq. mm and upto 400 sq. mm) direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required - 3.5 core 300 sqmm (70mm)
Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required - 3.5 core 150 sqmm
Supplying and fixing of the following Safety Equipments: a) ISI marked 4.5 Kg capacity CO2 Fire Extinguisher with bracket etc.,
b) Fire buckets with Stand filled with sand and water with roof top cover.Make: excellent
c) 415V Danger board as per the regulations with local language (8''x8'')
BUY BACK ITEM: 250 KVA Transformer
BUY BACK ITEM: RMU / LBS Panel
BUY BACK ITEM: LT Panel
BUY BACK ITEM: 4-pole RCC structure
shanti enterprises electricals pvt ltd
Polyphase Engineering Pvt Ltd
Maverik Facility Management PVt. Ltd.
classic eletricals and egineers
KATAKAM INFRA PROJECTS INDIA PRIVATE LIMITED
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.23 MB
Tender3.pdf
Tender Documents • 1.90 MB
BOQ_589867.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .