Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.5 LAccepted-AOC | L1 | Accepted-AOC OK | |
| 2 | L2₹7.7 L+₹8,322 (1.09%)Rejected-AOC H M APARTMENT FLAT NO 5C SJ ROAD ATHGAON GUWAHATI 781001 ASSAM | KAMRUP METRO | ASSAM | 781001 | L2 | Rejected-AOC OK | |
| 3 | L3₹7.9 L+₹28,002 (3.68%)Rejected-AOC H M APARTMENT 4C S J ROAD ATHGAON GUWAHATI 781001 | GUWAHATI | KAMRUP METRO | ASSAM | 781001 | L3 | Rejected-AOC OK | |
| 4 | L4₹8.4 L+₹77,825 (10.2%)Rejected-AOC | L4 | Rejected-AOC OK | |
| 5 | L5₹8.4 L+₹79,299 (10.4%)Rejected-AOC AZARA BHARALIPARA NEAR AZARA PUBLIC HALL GUWAHATI 781017 ASSAM | KAMRUP METRO | ASSAM | 781017 | L5 | Rejected-AOC OK |
Tender Value
₹7.2 L
EMD Value
₹14,200
Closing Date
1 Sept 2020, 6:00 pmClosed
AGE (I) AF Digaru
AGE (I) AF Digaru PO Digaru Dist Kamrup Assam 782401
REPAIR/MAINTENANCE OF SUMMER APPLIANCES, SPLIT TYPE AC, WATER COOLER, REFRIGERATOR, WINDOW TYPE AC AND OTHER ALLIED WORKS AT AF STN DIGARU
2020_MES_368679_1
8380/E8 of 2020-21
Open Tender
Miscellaneous Works
Item Rate
180 days
Digaru
MES contractor enlisted as class E cat b (i) having deposited standing security of Rs 36000 with dept.
5 documents required · 5 mandatory
₹500
Yes
AGE (I) AF Digaru
₹14,200
Yes
6 Feb 2021
12 Aug 2020
3 Sept 2020
12 Aug 2020
1 Sept 2020
20 Aug 2020
Amount
M&L Dismounting window AC of cap 1.5/2TR to the ground level transporting to near water point in the complex taking out the AC from outer cover ,washing the unit with soap solution jet followed by clean water jet Servicing/cleaning to complete with air blower , Cleaning of Condenser / Eva porter Coil Units with Air Blower & then wet servicing of Condenser / Eva porter Coil Units with washing soda etc , Checking of complete wiring , tightening of loose wire connections with proper Lugs / Clips. Renewal of defective wiring & terminal connector , Proper setting of thermostat & other Electrical / Refrigerant controls, cleaning of air filter , reinstallation & testing for proper functioning / cooling effect and writing the mentioning AC No/ Ser No complete all as specified and directed by Engineer-in-Charge. Note- Cost of hiring T&P deemed to be included.
Taking down defective /unserviceable Compressor and Supply and fixing new compressor sealed unit of suitable capacity / model in the unit properly for1.5 TR window type AC, ISI marked complete all as specified and directed by Engr-in-Charge.
All as per item No 2 here in before but AC 2 Ton capacity.
Taking down defective /unserviceable condensing coil and Supply and fixing suitable capacity/model condensing coil unit copper for window type AC Ton/1.5 Ton/2 Ton capacity ISI marked complete all as specified and directed by Engr-in-Charge.
Taking down defective /unserviceable blower motor and Supply and fixing new blower motor including fan blade, capacitor complete suitable for window type AC 1.5 ton/2.0 ton capacity 1/8 HP, 220 Volts, complete single phase, ISI marked all as specified and directed by Engr-in-Charge.
S&F in replacement cooling coil unit for window type AC of any type ISI marked complete all as specified and directed by Engr-in-Charge.
S&F in replacement starting capacitor 80/100 Mfd 230 V AC for window type AC 1.0 Ton/1.5 Ton/2.0 Ton capacity ISI marked complete all as specified and directed. (Make : Universal/Sarda )
S&F in replacement running capacitor 36/45/50 MFD 230 V for window type AC 1.0 Ton/1.5 Ton/2.0 Ton capacity ISI marked complete all as specified and directed. (Make : Universal/Sarda )
S&F in replacement overload protection coil 230 Volts for window type AC 1.0 Ton/1.5 Ton/2.0 Ton capacity ISI marked complete all as specified and directed.
S&F in replacement Relay suitable for window type AC 1.0 Ton/1.5 Ton/2.0 Ton capacity ISI marked complete all as specified and directed.
Supply and fix potential relay for window type AC 1.0/1.5/2.0 Ton capacity ISI marked after taking out existing unserviceable potential relay complete all as specified and directed.
S&F in repair thermostat suitable for window type Ac 1.0 ton/1.5 ton/2.0 ton capacity ISI marked complete all as specified and directed. (Make : Indofoss or equivalent as approved).
M&L checking the leakage of the system 1.5/2 Ton window type AC by feeding dry nitrogen to maintain adequate pressure in the system plugging the leak and charging gass R- 22 compieted all as specified and directed by Engr-in-charge. (Note : The refrigerant gas M-22/R-22 shall be measured and paid separately as ‘supply gas only’).
Taking out complete unserviceable wiring for AC window type 1.5 ton/2.0 ton capacity and rewiring with suitable size multi stranded copper cable including testing, checking etc complete all as specified and directed.
S&F capacitor for blower motor suitable for window type AC 1.5 ton/2.0 ton capacity including taking out old unserviceable capacitor ISI marked complete all as specified and directed.
S&F fan blade for blower motor suitable for window type AC 1.5 ton/2.0 ton capacity including taking out old unserviceable fan blade complete all as specified and directed.
S&F fan blade for window type AC of any capacity including taking down old unserviceable fan blade complete all as specified and directed by Engr-in-charge.
S&F swinging/oscillation motor with louvers as per existing make for window type AC 1.5 ton/2.0 ton capacity including taking out old unserviceable swinging motor ISI marked complete all as specified and directed.
S&F in repair PCB for control unit for window type AC 1.5 ton /2.0 ton capacity as per existing make or ISI marked complete all as specified and directed.
S&F in repair blower motor of window type AC 1.5Ton/2.0Ton ISI marked complete all as specified and directed.
Repair/rewinding to blower motor of wndow type AC 1.5/2.0 Ton complete all as specified and directed.
M&L for bearing/bush for blower and fan motor of capacity 1.5/2.0 TR after taking out old unserviceable motor complete all as specified and directed.
M&L for servicing of split type Air conditioner of cap1/1.5/2 Ton , cleaning of Split type AC indoor / outdoor unit complete with air blower , cleaning of Condenser / Eva porter Coil Units with air Blower & then wet servicing of Condenser Coil Units with washing soda etc , Checking of complete wiring , tightening of loose wire connections with proper Lugs / Clips. Renewal of defective wiring & terminal connector , Proper setting of thermostat & other Electrical / Refrigerant controls, cleaning of air filter , reinstallation & testing for proper functioning / cooling effect complete. (NOTE: The spare parts shall be measured & paid separately. Gas charge will be meassured and paid separately and if the AC is requried dismantling for repair to work shop rete are dismantling,refixing and transporation deemed to be included).
Supplyand fixing new compressor seal unit of suitable capacity/model in the unit properly for 1 TR split type AC ISI marked complete all as specified and directed.
Supplyand fixing new compressor seal unit of suitable capacity/model in the unit properly for 1.5 TR split type AC ISI marked complete all as specified and directed.
All as per item No 34 here-in-before but 2 TR .
Supply and fixing condensing coil unit for split type AC 1.0 / 1.5 / 2.0 ton capacity all as specified and directed by Engr-in-charge.
M&L checking the leakage of the system 1 to 2Ton split type AC by feeding dry nitrogen to maintain adequate pressure in the system plugging the leak and charging gass R- 22 compieted all as specified and directed by Engr-in-charge. (Note : The refrigerant gas M-22/R-22 shall be measured and paid separately as ‘supply gas only’).
S&F starting capacitor 80/100 Mfd 230 Volts AC for split type AC 1.0 / 1.5 / 2.0 ton capacity including taking out old unserviceable capacitor ISI marked complete all as specified and directed.
S&F running capacitor 36/45/50 Mfd 230 Volts for split type AC 1.0 / 1.5 / 2.0 ton capacities including taking out old unserviceable capacitor ISI marked complete all as specified and directed.
S&F overload protection coil 230 Volts AC for split type AC 1.0 / 1.5 / 2.0 ton capacities including taking out old unserviceable overload protection coil ISI marked complete all as specified and directed.
S&F relay suitable for split type AC 1.0 / 1.5 / 2.0 ton capacity including taking out old unserviceable relay ISI marked complete all as specified and directed.
S&F in repair copper pipe 5/8" / 1/2" / 3/8" / 1/4" dia (as per existing one) for connection indoor and out door unit ISI marked complete all as specified and directed.
S&F in repair PVC insulated PVC sheathed 1.5 Sqmm, 3 core copper cable 1100 Volts complete all as specified and directed.
S&F in repair PVC insulated PVC sheathed 2.5 Sqmm, 3 core copper cable 1100 Volts complete all as specified and directed.
S&F in replacement swinging motor with louvers as per existing old unserviceable swinging motor with louvers ISI marked complete all as specified and directed.
S&F blower motor including fan blade, capacitor complete (indoor unit/out door unit) for split type AC1/ 1.5 ton / 2.0 ton capacity 220 volts, single phase including taking out old unserviceable blower motor ISI marked complete all as specified and directed.
S&F fan blade for blower motor suitable for split AC 1/1.5 ton / 2.0 ton capacity including taking out old unserviceable blade complete all as specified and directed.
S&F fan blade for outdoor unit of split type AC of any capacity including taking down old one all as directed by Engr-in-charge.
S&F LCD / LED display unit for split type AC1/1.5 / 2.0 ton capacity including taking out old unserviceable unit ISI marked complete all as specified and directed.
S&F in repair 15/20 mm bore PVC flexible drain pipe of water complete all as specified and directed.
S&F in repair PCB for control unit for split type AC 1/1.5 / 2.0 ton capacity as per existing make or ISI marked complete all as specified and directed.
M&L for replacement of unserviceable bearing/bush for blower and fan motor of capacity 1.0/1.5/2.0 TR complete all as specified and directed.
Repair/rewinding to blower motor of Split type AC 1 Ton/1.5/2.0 Ton complete all as specified and directed.
S&F angular valve of size 1/2" suitable for split type AC as in repair complete all as specified and directed by Engr-in-charge.
S&F angular valve of size ¼" suitable for split type AC as in repair complete all as specified and directed by Engr-in-charge.
S&F angular valve of size 5/8" suitable for split type AC as in repair complete all as specified and directed by Engr-in-charge.
S&F industrial socket as in repair complete all as specified and directed by Engr-in-charge. (Make : HPL cat no HP2820).
Shifting of serviceable split AC of any capacity from one location to another location complete all as directed by Engineer-in-charge (Note : Spares such as fast nut and stand shall be measured and paid seperately but labour cost deemed to be included in this item).Note- Cost of transporation of AC deemed to be included.
Supply and fixing in replacement stand for split AC.
M & L for providing black foam insulation of adequate thickness over copper tubing of any size complete all as specified and directed by Engr-in-Charge.
M&L for sub main wiring with 2 run of 6 Sqmm (nominal cross-sectional area) FRLS PVC insulated unsheathed multistranded copper conductor, single core , working voltage 1100 volts grade conforming to IS-694 in and including PVC casing capping of suitable size heavy duty ISI mark double locking system including size 4 sq mm (nominal cross sectional area) FRLS PVC insulated un-sheathed single core multi stranded copper conductor cable as earth continuity conductor connected to main switches/DB"S or common earth dully complete all as specified and directed after taking down old sub main wiring complete and making good the disturbed surface. (Make : FINOLEX/NICCO/ Harsh for copper cable and PRESTOPLAST/PLAZA/Harsh for casing capping and accessories)
M&L for industrial plug and socket including MCB, SPN, 20 Amps switched isolator top, 230 volts, 50 Hz complete all as specified and directed by Engr-in-charge as in repair. (Make : HPL/Legrand/ABB)
S&F industrial plug top as per IS as in repair complete all as specified and directed by Engr-in-charge. (Make : HPL, cat No HP2P20)
M&L for MCB, SP, 240 volt, 6 to 32 Amps, ‘C’ series, 10 KA as in repair complete all as specified and directed by Engr-in-charge. (Make : Legrand/ABB/L&T).
M&L for MCB, SPN, 240 V, 40 to 63 Amps, ‘C’ series, 10 KA as in repair complete all as specified and directed by Engr-in-charge. (Make : Legrand/ABB/L&T).
M&L for dismantling of deep frizer of any type capacity in various location, shifting to MES Yard if required for repair/replacement of unserviceable spares and painting the outer body (including replacement of corroded sheet by welding/brazing with suitable new sheet metal) by spraying enamel paint and marking/sticking a sticker mentioning the MES No and reassembling, testing, checking and shifted to existing location, fixing the same by nut, bolt, angle iron structure and masonry work complete all as specified directed by Engineer-in-Charge. (NOTE: The spare parts shall be measured & paid separately as supply only rates. Rates for fixing of spares parts under relevant item No 63, 64, 65 & 66 shall be included in item No 62).
Supply only new compressor sealed unit of suitable capacity/model in the unit properly for deep frizer of any capacity ISI marked complete all as specified and directed by Engr-in-charge.
S&F in replacement of cooling coil unit for deep frizer of any type ISI marked complete all as specified and directed by Engr-in-Charge.
S&F in replacement of relay for deep frizer of any type ISI marked complete all as specified and directed by Engr-in-Charge.
S&F in replacement of ant type capacitor for deep frizer ISI marked complete all as specified and directed by Engr-in-Charge.
M&L checking the leakage of the system deep frizer of any capacity by feeding dry nitrogen to maintain adequate pressure in the system plugging the leak and charging gass 134 A compieted all as specified and directed by Engr-in-charge. (Note : The refrigerant gas 134 A shall be measured and paid separately as ‘supply gas only’).
M&L for dismantling of storage type water cooler of any type capacity in various location, shifting to MES Yard if required for repair/replacement of unserviceable spares and painting the outer body (including replacement of corroded sheet by welding/brazing with suitable new sheet metal) by spraying enamel paint and marking/sticking a sticker mentioning the MES No and reassembling, testing, checking and shifted to existing location, fixing the same by nut, bolt, angle iron structure and masonry work complete all as specified directed by Engineer-in-Charge. (NOTE: The spare parts shall be measured & paid separately as supply only rates. Rates for fixing of spares parts under relevant items.
Supply only new compressor sealed unit of suitable capacity/model in the unit properly for storage type water cooler of any capacity ISI marked complete all as specified and directed by Engr-in-charge.
Supply only blower motor fan for water cooler of any capacity including taking down old unserviceable blower motor fan ISI marked complete all as specified and directed by Engr-in-charge.
M&L for dismantling of storage type refrigerator of any capacity in various location, shifting it to MES yard if required for repair/replacement of unserviceable spares and painting the outer body (including replacement of corroded sheet by welding/brazing with suitable new sheet metal) by spraying enamel paint and marking/sticker mentioning the MES No, reassembling, testing, checking and shifted to existing location including masonry work complete all as specified & directed by Engineer-in-Charge. (NOTE: The spare parts shall be measured and paid separately as supply only rate. Rates for fixing of spare parts shall deemed to be included in this item)
Supply only new compressor seal unit of suitable capacity / model in the unit properly for domestic refrigerator of any type ISI marked complete all as specified and directed by Engr-in-charge.
M&L for charging refrigerant gas 134A in the system of domestic refrigerator of any type all as directed by Engr-in-charge..
M&L for replacement of capillary tube and stainer for any type and capacity of domestic refrigerator ISI marked complete all as specified and directed.
Supply only cooling coil unit for domestic refrigerator of any type ISI marked complete all as specified and directed by Engr-in-charge.
S&F in repair timer/bimetallic relay of existing type for domestic refrigerator ISI marked complete all as specified and directed by Engr-in-charge.
S&F in repair relay for domestic refrigerator of any type complete all as specified and directed by Engr-in-charge..
S&F thermostat for domestic refrigerator of any type including taking out old unserviceable thermostat ISI marked complete all as specified and directed.
Taking out complete unserviceable wiring for domestic refrigerator of any type and rewiring with suitable size multi stranded copper cable including testing , checking etc complete all as specified and directed by Engr-in-charge.
S&F magnetic door gasket screw for refrigerator of any capacity including taking out unserviceable one complete all as specified and directed by Engr-in-charge.
S&F handle for opening domestic type refrigerator of any type including taking out old unserviceable handle complete all as specified and directed by Engr-in-charge.
S&F material keeping tray for domestic refrigerator of any type including taking out old unserviceable tray complete all as specified and directed by Engr-in-charge.
S&F chiller tray for domestic refrigerator of any type including taking out old unserviceable chiller tray complete all as specified and directed by Engr-in-charge.
S&F freezer door (indoor) for domestic refrigerator of any type including taking out old unserviceable freezer door complete all as specified and directed by Engr-in-charge.
Supply only Remote control for split type AC of existibg AC of 1.5 TR/2 TR complete all as specified and directed by Engr-in-charge
Supply only battery of capacity 1.5 volt for remote control device for any type and capacity complete all as specified and directed by Engr-in-charge. (Make : Duracell/Eveready)
S & F in repair Base plate of window type AC 1.5 & 2 Ton complete all as specified and directed by Engr-in-charge.
Labour only for attending day to day complaint and rectfi to complaint pertain to all type of AC , Water cooler, Refrigerator ,voltage stablizer etc as when required for the checking the equipment at existing location and find out the faults/ defects and rectify the defects in side including rectified electrical fault from existing DBs to functional box and cleaning /normal maintenance to be equipments complete to make the equipment functional in all respect all as directed . complete shall be collected from site incharge (JE on daily basis . complaint shall be attend with in 24 hrs of complaint lodged .if complaint is not attended in the specified time period panaltyshall be charge to the contractor @ 500 / per day per complaint . Note- Spare parts required will be measured and paid separetly)
M/s JK Jangid and Company
M/S. SUBHAS CONSTRUCTION CO.
M/s Capital Traders
Ms N D Enterpise
M/s Dhruv Enterprises
M/S Vimal Enterprise
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .