Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.6 LAccepted-Finance 28 A KG MARG CENTRAL DELHI DELHI 110001 | NEW DELHI | DELHI | 110001 | L1 | Accepted-Finance Admitted being the lowest. | |
| 2 | L2₹21.0 L+₹4.3 L (26.0%)Rejected-Finance 45 58 5 15A AKSHAYA NARASIMHANAGAR VISAKHAPATNAM 530 024 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530024 | L2 | Rejected-Finance L1 Being the lowest. | |
| 3 | L3₹22.4 L+₹5.8 L (34.8%)Rejected-Finance HARINAGAR BEHIND MAHESHWARY MARKET PO TATISILWAI DIST RANCHI PIN 835103 | RANCHI | JHARKHAND | 835103 | L3 | Rejected-Finance L1 Being the lowest. | |
| 4 | Rejected-Technical NO 23 SECOND MAIN ROAD RAJAMMAL NAGAR MADAMBAKKAM CHENNAI 600 126 | CHENNAI | CHENGALPATTU | TAMIL NADU | 600126 | - | Rejected-Technical Rejected Due to Non submission of MOU with OEM. |
Tender Value
₹16.6 L
EMD Value
₹33,300
Closing Date
11 Dec 2023, 6:00 pmClosed
Garrison Engineer (I)(CG) Chennai
Garrison Engineer (I) (CG) Military Engineer ServiceCGRA Meenambakkam Building No P 16 NGO Colony 4th Street Nanganallur Chennai 600 061
Repair and routine maint of electrical lifts installed at CGRA Phase I Thalakancherry area under GE (I) (CG) Chennai
2023_MES_626225_2
8076/E8/GE(I)CGCHENNAI
Open Tender
Electrical and Maintenance Works
Item Wise
365 days
Garrison Engineer (I)(CG) Chennai
All as per tender documents
8 documents required · 8 mandatory
₹500
Garrison Engineer (I)(CG) Chennai
₹33,300
Yes
26 Dec 2023
28 Nov 2023
13 Dec 2023
28 Nov 2023
11 Dec 2023
29 Nov 2023
Amount
SCHEDULE 'A' - PART I (MAINTENANCE)
Comprehensive Maintenance and repairs of electriclly operated lifts of ECE Make 07 Nos at CGRA Thalkancherry including renewal/replacement of defective parts of Automatic Rescue device and over load warning device with a capacity of 10 passengers lift , 680 kg each-07 Nos for 6 stops/6 landings ,1.0 metre/Sec ,single speed single push button control system with micro processor control system with collectve control scheduled in Appx A by carrying out periodical checks , repairs and testing as per Proforma no :01 to 05 as recommended by the manufacturer to ensure smooth functioning and efficient operation including fixing only for the items mentioned below in schedule A part II ..
Comprehensive Maintenance and repairs of electriclly operated lifts of ECE Make 2000 KG capacity Goods Lift ,07 Nos at CGRA Thalkancherry including renewal/replacement of defective parts of Automatic Rescue device and over load warning device with 2000 kg each-07 Nos for 6 stops/6 landings ,0.50 metre/Sec ,single speed single push button control system with micro processor control system with collectve control scheduled in Appx A by carrying out periodical checks , repairs and testing as per Proforma no :01 to 05 as recommended by the manufacturer to ensure smooth functioning and efficient operation including fixing only for the items mentioned below in schedule A part II ..
Note for item No 2 to 3 (i) The spares/electrical items as listed in Sch 'A' will be used whenever required only and measured and paid separately under respective items. (ii) The rate is inclusive of all items as required at site except those items as given in supply only to keep the lift operational round the clock including cleaning and greasing all moving parts on monthly basis complete all as specified and as directed by Engineer-in-Charge. (iii) If spare parts of original make is not available in market necessary suitable spare equivalent to existing lift part as approved by GE shall be used in the work so that to run the lift with smooth functioning. (iv) Cost of renewal of lift license is deemed to be included in the quoted rate .
(v) Quoted rate incl the testing of all the lifts by licensed Lift Inspector of tamil nadu twice in contract period for saftey.Certificate issued by the licensed lift inspector shall be submitted to Eng-in-charge. (vi) In case of any of the lift/lifts is/are not working for more than 24 hours but less than 10 days, Recovery will be affected at the rate of Rs 2,000/- per lift per day and Rs 3,000/- per lift per day after 10 days. (vii) The above lifts shall be repaired through OEM (Original Equipment manufacturer) or through their nearest authorised/accredited agency service personel only.The lowest bidder shall submit and uploading MoU from the OEM of lift or their authorised/accredited agency at time of uploading of tender. (viii) Contractor should submit all valid docucments before the opneing of tehcnicial bid.
SCHEDULE 'A' - PART II ( SPARE PARTS)
Supply only mother board APCLD R 4 Make ECE
Supply only Door drive PKS 16 Make ECE
Supply only Main drive for goof lift Make: Toshiba
Supply only Main drive for 10 passanger lift make Yashkawa
Supply only Door motor make ECE
Supply only Door lock contact make ECE
Supply only Landing / Car door shoe make ECE
Supply only Door bearing make ECE
Supply only Break arm make ECE
Supply only Break pad make ECE
Supply only Main sheave make ECE
Supply only Break drum make ECE
Supply only Limit switch make ECE
Supply only Jc switch make ECE
Supply only Reed switch make ECE
Supply only Gear oil EP 460 make servo
Supply only VFVR Relay card , DC 24/110V make ECE
Supply only Transformer for controller T-500 input 230V AC output 90/20 V ac make ECE
Supply only OEN Relay DC 24V make Sallzer
Supply only Contactor assembly 4 pole DC 110V 32 Amps with Auxiliari contact Make :Siemen / ABB
Supply only SMPS Input 230V AC output 54V DC
Supply only VMVFCard DC 24V make ECE
Supply only Micro card for automatic rescue device Make Jeltron
Supply only Charger Card for automatic rescue device Make jeltron
Supply only Converter Card for automatic rescue device Make Jeltron
Supply only Transformer for automatic rescue device input 230V Output 12/110V DCand 230V AC
Supply only Six Relay Card DC 24V Make : ECE
Supply only Twelve Relay Card DC 110V Make : jeltron
Supply only MCB DP 20 Amps Make : Schneider
Supply only Full length sensor (Make Meco) Suitable for 10 passanger lift Make ECE
Supply only Floor Position Indicator Card Make ECE
Supply only illuminated Bush Button Working on DC 24V Make ECE
Supply only SS indicator Plate 1.5mm thick suitable for Full Collective lift Electronic Car Position Indicator make ECE.
Supply only Auxillary Contact Coil Amps With 4Nos NC AC 230V Make : Siemen / ABB
SCHEDULE 'A' - PART III
Taking down Main motor 3 phase 380 Volts, up to 09 KW, 1300/325 RPM and Material and labour for rewinding the same using suitable gauge of copper winding wire and all insulation item including varnishing drying and refixing of AME at site testing and incluing replacement of any minor parts if necessary including fixing of new nuts and bolts for foundation etc complete all as specified and as directed.
Taking down Main motor 3 pohase 380 Volts, up to 15 KW, 1300/325 RPMand Material and labour for rewinding the same using suitable gauge of copper winding wire and all insulation item including varnishing drying and refixing of AME at site testing and incluing replacement of any minor parts if necessary including fixing of new nuts and bolts for foundation etc complete all as specified and as directed.
Taking down cabin fan single phase, 230Volts and Material and labour for rewindingthe same using suitable gauge of copper winding wire and all insulation item including varnishing, drying and refixing of fan in lift cabin and testingcomplete all as specified and as directed.
Rewinding of break coil including opening and cutting old brunt out winding and Material and labour for rewindingthe same using suitable gauge of copper winding wire and all insulation item including varnishing, drying and refixing in same position and testingcomplete all as specified and as directed.
Supply and fix 10 watt (2') Tube light fitting. Make: havells Cat No: ENDURALINARNEARNEOBS10WLED 865 SPCWH or equivalent of philips, CG etc.
Velox Engineering Solutions Pvt Ltd
UNIVERSAL ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .