Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹26.2 LAdmitted-Finance | -28.54% | ₹26.2 L | L1 | Admitted-Finance |
| 2 | L2₹26.8 LAdmitted-Finance | -26.95% | ₹26.8 L | L2 | Admitted-Finance |
| 3 | L3₹27.7 LAdmitted-Finance | -24.37% | ₹27.7 L | L3 | Admitted-Finance |
| 4 | L4₹29.0 LAdmitted-Finance | -20.77% | ₹29.0 L | L4 | Admitted-Finance |
| 5 | L5₹32.8 LAdmitted-Finance | -10.52% | ₹32.8 L | L5 | Admitted-Finance |
Tender Value
₹36.6 L
EMD Value
₹73,260
Closing Date
19 Jan 2026, 4:00 pmClosed
Er Pawan Tickoo
Executive Engineer PWD RandB Electric Div Jammu
please refer BOQ
2026_PWDJK_300133_1
e-NIT No.EDJ/170 of 2025-2026 Dated 07-01-2026
Open Tender
Electrical Works
Amphalla Jammu
please refer to NIT
2 documents required · 2 mandatory
₹600
Executive Engineer PWD RandB Electric Div Jammu
₹73,260
20 Feb 2026
8 Jan 2026
20 Jan 2026
8 Jan 2026
19 Jan 2026
8 Jan 2026
Wiring for light point/ fan point / exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with modular switch, modular plate, suitable GI box earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required (Group-A)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 amps & 15/16 amps. modular socket outlet and 15/16 amps modular switch connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25/20 A modular socket outlet and 25/32 A modular DP MCB, "C" curve including connections, painting etc. as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Wiring for circuit/ sub-main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required.
2 x 1.5 Sq.mm + 1 x 1.5 Sq.mm earth wire
2 x 2.5 sq mm + 1 x 2.5 sq. mm earth wire
2 x 4 sq. mm + 1 x 4 sq. mm earth wire
2 x 6 sq. mm + 1 x 6 sqmm earth wire
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
4 x 10 sq. mm + 2 x 6 sq. mm earth wire
4 x 16 sq. mm + 2 x 6 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required.
1 x 1.5 sq. mm
Supplying and fixing of ceiling fan of followingsweep with 2.25 mfd condenser and 1'-6" down rod on the existing fan hook with necessary connection from ceiling rose to fan using twin core copper wire. (As approved site in-charge)
1200 mm sweep (3 Star)
1200 mm sweep Decorative Fan as approved site engineer
1200 mm sweep Aero Dynamic type (Silent)
Supplying and fixing of 400 mm sweep wall mounting fan (oscillating type) on wall with necessary connection as required.
Supplying and fixing of following sizes Transair exhaust fan with metal blade complete set on existing holes on wall with necessary connection from ceiling rose to fan using 2 core flexible copper wire.
225 mm / 9" sweep exhaust fan
300mm/12" sweep exhust fan
300mm/12" sweep exhust fan (Heavy Duty)
Supplying and fixing of fan hook (U hook) on celiling with 4 nos. of anchor fastener on both ends with necessary bolts and nuts and mansonry work as required.
Supplying and fixing of following sizes extra down rod with twin core flexible copper wire for ceiling fan.
Making round shaped hole on the wall including supply and fixing of necessary cement concrete collar to suit 300 mm heavy duty exhaust fan and finishing the wall to make good.
Supplying & fixing of following way horizontal type three pole and netural, sheet steel, MCB distribution board, 415 volts, on surface/ recess complete with tinned copper bus bar neutral buss bar, earth bar,din bar interconnection nection,powder painted including earthing etc. as required.
4 Way (4+12), (Double door )
6 way ( 4+18), (Double door)
8 way (4+24), (Double door)
Supply, installation, testing & commissioning of GI Electrode Earthing with 50mm dia and 2 meter length, with 3mm thick the electrode should be hot-dip galvinised. The GI Electrode shall be pre-filled with Cristaline Conductive Materila (CCM). The GI electrode shall be surrounded with BEE MOIST compound to provide maximum contact betwen the electrode and compound should be eco-friendly GI Electrode Earthing should be maintinance free and does not require regular manual addition of water . The earthing pit should be covered with PVC cover.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Supply, installation, testing & commissioning of maintenance free copper earthing system with 2 mtrs. Electrode 40 mm dia with minium 2mm thick and does not require manual additional of water. The electrode shall be pre-filled with hygroscopic powder and provided with suitable breathing and leaching ports at the ends. the electrode shall be surrounded by suitable powdered form of BEE MOIST so as to provide maximum contact between the electrode and the compund. The compound should be eco-friendly The earthing pit should be covered with PVC cover.
Providing and fixing of 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
Supplying and fixing of following sizes of PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. (ISI Make).
20/25 mm flexible pipe
Supplying, installation, Testing & Commissioning of 18- 22 watt LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm)
Supplying, installation, Testing & Commissioning of 36 watt Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K / 6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm)
Supplying, installation, Testing & Commissioning of 18 watt LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminum Body including trim (As per engineer in site in-charge).
Supplying, installation, Testing & Commissioning of 120 watt Street light LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP- 66,IK-10, CRI >80, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).
Supplying, installation, Testing & Commissioning of 18 watt LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C)
Providing & fixing of following accessories.
5/6 Amp. 3 pinTop
5/6 Amp 2 pin Top
15/16 Amp 3 pin top
Insulation Tape (ISI brand)
Celing Rose
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.
1 or 2 Module (75mm x 75mm)
3 Module (100mm x 75mm)
4 Module (125mm x 75mm)
6 Module (200mm x 75mm)
8 Module (125mm x125mm)
12 Module ( 200mm x 150mm)
18 Module
Suplying and fixing following modular switch/ socket on the existing modular plate & switch box inculding connection but excluding modular plate etc. as required.
5/6 amps switch
15/16 amp switch
3 pin 5/6 amp socket outlet
6 pin 15/16 socket outlet
Telephone socket outlet
TV Antenna socket outlet
DP Switch 32 Amp with Indicator
Bell push
Supplying and fixing of following rating 240/415 volts "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole upto 32 amp.
Single pole and neutral upto 32 amp.
Single pole and neutral 32 amp. (Modular)
Single pole and neutral 40 Amp
Single pole and neutral 63 Amp
Single pole and neutral 100 Amp
TPN 40 Amp
TPN 63 Amp
Supplying and fixing single pole blanking plate in the existing MCB DB Complete etc. as required
SITC of wall/free standing floor mounted dust and vermin proof compartmentalized cubical panel for electrical Works, made out of CRCA sheet. Other parameters required as per point (a) Thickness of sheet shall not be less than 1.6 mm up to 600 mm length/width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartment shaving bolted type doors with/without detachable extension type structure (b) Panel shall be duly treated for derusting in 7 tank process with de phosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/Neoprene rubber gasket of not less than 3mm thickness, required hardware, separate detachable gland plate M.S. base channel (min 75mm), hinged door with locking arrangement for equipment/switchgear c) Interconnection between bus bar and switch gears/cable shall be rigidly supported and made out by flexible copper wires (upto 125 amp) and by solid bus bar (> 125). (d) Only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator CPRI Test certificates to be submitted) All as per pre approved by Engineer in charge.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Thermal Magnetic type, Adjustable type)
40 Amp, 25 KA, FP MCCB ICU = 100% ICS
63 Amp, 25 KA, FP MCCB ICU = 100% ICS
100 Amp, 30 KA, FP MCCB ICU = 100% ICS
125 Amp, 36 KA, FP MCCB ICU = 100% ICS
Electrical Rubber Mat having thickness 6mm and width 1 Mtr
ON Load Change Over Switch FP 100 amp. (Front operated)
ON Load Change Over Switch FP 200 amp. (Front operated)
Aluminium Bus Bar 100 Amp set of 4 strips
Aluminium Bus Bar 200 Amp set of 4 strips
Aluminium Bus Bar 300 Amp set of 4 strips
Supplying & laying of PVC insulated and PVC sheathed/ XLPE Aluminium power cable of 1.1 KV grade of following size on surfaces/ direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (Armoured cable)
35 sq. mm 3.5 core
50 sq. mm 3.5 core
70 sq. mm 3.5 core
Supplying & Drawing of Co- axial TV cable RG-6 grade, 0.7 mm solid copper conductor.
Supplying & Drawing of UTP 4 point Cat-6 cable (1 run cable) (D-Link, Schneider, Systimax)
Supplying & fixing of Electrical Accessories PVC Casing and Caping (Batten).
4" Deep Box
5" Fan Box
Conceeled Box
Junction Box (Metal)
Supplying and fixing of Phenolic Laminated Sheet 9" x 11" including cutting the space for switches/socket etc.
Supplying and fixing of Phenolic Laminated Sheet 9" x 6" including cutting the space for switches/socket etc.
Supplying and fixing of Phenolic Laminated Sheet 4" x 4" including cutting the space for switches/socket etc.
Supplying and fixing of Phenolic Laminated Sheet 11" x 13" including cutting the space for switches/socket etc.
Supplying and fixing of Phenolic Laminated Sheet 6" x 3" including cutting the space for switches/socket etc.
Supply and fixing of single phase of following rating self priming for pumping water including connections etc as required. (Copper winding)
Supplying & fixing of Battery 12 Volt. Tubular 150 AH with 36 months Guarantee Invertor Sinewave 1650-1850 VA and required Trolley as per site vrequirement approved by Engineer in charge
Supply, Installation, Testing & Commissioning of IP Dome Camera -Video Standard PAL/NTSC,Image Sensor 1/2.8” CMOS,Number Of Pixels (H × V) 1920(H) × 1080(V),Minimum Illumination 0.0035 [email protected], AGC ON 0 lux with IR ON,S/N Ratio > 50 dB,Electronic Shutter Speed 1s ~ 1/ 100,000s,IR Distance Up to 50 m, Day/Night Auto (ICR)/Day /Night/Timing ,Backlight Compensation BLC, HLC White Balance Auto/Indoor /Outdoor/ Manual,Wide Dynamic Range Digital WDR,Noise Reduction 3D DNR,Privacy Masking Off / On (4 Areas),Motion Detection Support,Region Of Interest Support (3),Lens 2.8 mm, Fixed Angle Of View H: 105.4°, V: 72.9°,Audio One way, Inbuilt Microphone,Video Compression Resolution H.265 / H.264,Frame Rate Bit Rate Control CBR / VBR Bit Rate 64 Kbps ~ 6 Mbps 1080P(1920×1080), 720P(1280×720), D1(704×576), CIF(352×288), 480×240 Main stream: 1080P/720P (1~25/30fps) Sub stream: D1/CIF (1~25/30fps) Third stream: D1/CIF/480x240 (1~25/30fps),Interoperability ONVIF Profile S, G Maximum Users Access 3 Users Protocols* IPv4, IPv6, TCP/IP, HTTP, HTTPS, UPnP, RTSP, IGMP, SMTP, DHCP, NTP, DNS, DDNS, QoS, 802.1X, UDP, ICMP, ARP, TLS Security User account and password protection, HTTPS, IP Filter, TLS1.2, AES-128 ,Micro SD Micro SD/SDHC/SDXC card slot (128GB),Operating Temperature,Certification CE, FCC, RoHS -30°C ~ 60°C (-22°F ~ 140°F),Ingress Protection IP67 IR= 50 Mtrs Make:- Bosch, Pelco, Sumsung, Sony, Honey well WS- 35 series, AXIS
Supply Installation Testing and Commissioning of 5MP or better Indoor Bullet camera with 5MP resolution (2592 x 1944) @30fps, H.265/H.264/MJPEG Video Bit Rate 64 Kbps-5 Mbps, Audio Compression G.711/G.711U/ADPCM, Audio Bit Rate 64 Kbps-5 Mbps, Image Sensor 1/2.9" CMOS, Signal System PAL/NTSC, Min. Illumination Color: 0.02Lux@ (F2.0, ACG ON), B/W: 0Lux with IR, Shutter Time 1s to 1/100,000s, Day & Night Dual IR Cut Filter with Auto Switch, Wide Dynamic Range 120dB, Angle Adjustment Bracket, pan: 0° to 360°, tilt: 0° to 75°, rotate: 0° to 360°, Lens type - Fixed, Focus 4mm, Lens Mount M12, Aperture F2.0, Fixed FOV Horizontal field of view: 82.1° (4mm), IR LEDs 2, IR Range Up to 50m, Wavelength 850nm, Alarm Trigger-Motion Detection, Mask Alarm, IP Address Conflict, Protocols TCP/IP, HTTP, FTP, DHCP, DNS, DDNS, MULTICAST, IPV4, NTP, UDP, Telnet. Operating temperature -30°C~600C, 0-95% RH.System Compatibility ONVIF (PROFILE S/G), Protection IP67, Lightning protection, surge protection IR=50 mtrs, SNR > 70 dB, Quad Stream, SD Card Support: Up to 512GB. Make:- Bosch, Pelco, Sumsung, Sony, Honey well WS- 35 series, AXIS
SITC of 2MP IP PTZ Camera, with PoE, motorisedvari focal lens for 30x zoom, Minimum Illumination Color: 0.005 [email protected] B/W: 0.0005 [email protected] 0 [email protected] (IR light on), S/N Ratio ≥55Db, Effective Pixels 1920(H) x 1080(V), Image Sensor 1/2.8” 2MP PS CMOS (0.9071 centimeters), RAM/ROM 512MB/ 256MB, Electronic Shutter Speed 1/1s~1/30,000s, Focal Length 4.8mm~120mm Focus Control Auto; Semi-auto; Manual White Balance Auto; indoor; outdoor; tracking; manual; sodium lamp; natural light; street lamp Close Focus Distance 1.5 m, Resolution 1080P (1920 × 1080); 1.3MP (1280 × 960); 720P (1280 × 720); D1 (704 × 576/704 × 480); CIF (352 × 288/352 × 240) IVS and face detection support, Weather Proof Standard IP66; TVS 6000 V lightning proof; surge protection; voltage transient protection, Certificates are required ISO 9001, ISO 14001, ISO 27001, CMMI 5, BIS, GDPR and Cyber Security Built-in IR illuminator with 150m viewing distance etc complete as reqd.
Supply Installation Testing & Commissioning of 3 Core Power Cable 1.5 sqmm. Make: Finolex/Polycab/Havells
Supply, Installation, Testing and comissioning of 16 port Layer ‑2 unmanagable Switch with Power on Ethernet (PoE) enabled, with 16 nos. 10/100/1000base Tx PoE port with 2 SFP port, 1 no. dual personality Gbe Port for copper/fiber uplink, 20 Gbps switching capacity, 14.88 MPPS Forwarding performance , maximum power consumption 64 watt. Make: Cisco/D-link
Supply, Installation, Testing and comissioning of 24 port Layer ‑2 unmanagable Switch with Power on Ethernet (PoE) enabled, with 24 nos. 10/100/1000base Tx PoE port with 2 SFP port, 1 no. dual personality Gbe Port for copper/fiber uplink, 20 Gbps switching capacity, 14.88 MPPS Forwarding performance , maximum power consumption 64 watt. Make: Cisco/D-link
Supply , Installation , Testing and commissioning of 16 Channel NVR (Network Video Recorder) Embadded Linux based for recording upto 16CH @ D1 with 02 nos. SATA HDDs minimum 20TB storage or more (recording requirement all cameras recording at D1, 25fps for 30 days), H.265 HEVC/H.264/MJPEG codec decoding, Front Control Pannel with LEDs Indication, 2 nos. USB, ONVIF S, Time Sync with NTP, Encrypted Streaming & Control, 2-Way Audio Line & Out, PTZ Operation Pan, Tilt, Zoom, Support, Pre & Post Alarm Recording Support, Recording/Evidance Clip Export to USB, 16 Channel Syncronous Playback, Playback control i.e Play, Pause, Stop, Fast Forward, Backward, Timeline & Zoom; Snapshot, Web Client, Central Monitoring Softawre, iPhone; iPad; Android based Mobile clients, 01HDMI & 01VGA Output, 02 On Board HDDS each up to 10TB, Alarm Input (1 nos.), Alarm Output (01 nos.), NDAA Section 889 Compliant, Operating Temperature –10°C to 55°C, Certification : Certifications: ONVIF compliant, UL/CSA, CE, FCC, EN, NDAA & RoHS compliant.including fixing accessories and cable termination with required connectors/Jack, complete in all respect as per instruction of engineer in-charge. Make BOSCH/AXIS/Pelco/Honey well series 35
6 TB surveillance Hard disk storage device. 7200 RPM
4TB surveillance Hard disk storage device. 7200 RPM
Micro SD/SDHC Card 128 GB
1 mtr. Cat 6 Networking patch cord cable.
3 mtr. Cat 6 Networking patch cord cable.
Supply of following electrical /networking components.
ADSL Modem Router Double Antenna
Supply & Installation of IP-20 & IK-08 , UL Listed Wall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with 'U'Marking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19" angles with wall mounting provision on wall. Accessories like: 1 No of 19" 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19" 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastner etc as required.All as per pre approved by Engineer in charge
6 U Rack
9 U Rack
Supplying, installation, testing and commissioning of 120/120 Liters of water Cooler having full stainless steel body, cooling capacity 120 ltr/hour and storage capacity 120 ltr alongwith PVC connecting pipes as required. (ISO Certified) .
Supplying, installation, testing and commissioning of following type of water purifiers alongwith PVC connecting pipes as required.
(RO + UV + UF mineral control with TDS control )
Supplying, installation, testing and commissioning of 1.5 Ton Inverter type Split AC's (copper) Hot/ Cold (all weather) type of minimum capacity following Specification as detailed below. 1. Should be of inverter type 2. Cooling capacity (in Tr): 1.5 3. BEE Star rating: 3 4. Maximum local temperature: 52 C 5. Rated cooling capacity (BTU/hr.): 19000 or above 6. Condensing coil: 100% Copper with grooved copper tubes 7. Electrical input, 220 V ± 30/50Hz/Single Phase 8. Noise level (indoor unit): = close to 35 dB 9. Compressor type: rotary or any other suitable technology 10. Refrigerant type: R-32 11. Anti-Corrosive Coating for the outdoor unit: Bule Fin/Gold Fin or equivalent
12. Compressor Warranty: 10 years 13. PCB Warranty: 5 year 14. Total System Warranty: 1 year 15. Minimum noise level of the indoor unit should be around 28 dB (A) 16. Should have air filtering mechanism for removing dust 17 Supplier has to include brochure of the quoted model Each unit must provide cooling & dehumidification, be operatable via remote control, operate at 220-240 V AC supply with latest in vogue features. The job includes Repairs made to wall whereever as required.
Supplying, installation, testing and commissioning of 2.0 Ton Inverter type Split AC's (copper) Hot and Cold type of minimum capacity following Specification as detailed below. 1. Type:- Split (Indoor Unit & Outdoor Unit) 2. Cooling Capacity:- Not less than 6000 watts 3. Compressor type :- Twin Rotary type Compressor 4. Refrigerant:- Eco-friendly (Green Gas) (R-22/ R-32/ R-290/R-410A/R-600A) 5. Remote Control:- Yes 6. Swing:- Adjustable 7. Air flow adjustment:- Auto 8. Energy Efficiency i) ISEE Rating (Desired):- 03 Star Rating, Inverter type ii) BEE rated Energy Efficiency Ratio (EER):- Not less than 3.8 9. General features:- i) Filters:- Anti Bacteria/Dust filter etc. ii) Air Direction Control:- Air iii) Auto Restart:- Yes iv) Sleep Mode:- Yes
v) Timer:- Yes vi) Sound Level inside (in db):- Not more than 50 db & Sound lel outside (in db):- Not more than 56 db vii) inverter type split AC:- Yes viii) Power Supply/Consumption a) Power Supply (Volt/Phase/Hz.):- 230/Single/50 b) Power consumption (watts) with 100% loading:-Not more than 2000 watt c) Power consumption (watts) with 50% loading:- Not more than 900 watt d) Running Current (Amps):- Max 8.0 to - 9.0 Amps e) Operating Temperature (room) minimum:- 2 º C to 46 º C f) Maximum Outside (Ambient) Temperature:- Should be capable of operating at least upto 50 ºC Ambient Temperature 10. Compressor Warranty: 10 years 11. PCB Warranty: 5 year 12. Total System Warranty: 1 year Each unit must provide cooling & dehumidification, be operatable via remote control, operate at 220-240 V AC supply with latest in vogue features. The job includes Repairs made to wall whereever as required.
Supplying, Installation, Testing & Commissioning of following capacity automatic voltage stabilzer copper wound wall mounted, single phase with range of 90-240 V along with wall mounting brackets & fitting. The job includes repairing the walls where necessary. Warrantee.:- 2 Years from the date of installation.
Supplying, Installation, Testing & Commissioning of following capacity automatic voltage stabilzer copper wound wall mounted, single phase with range of 135-240 V along with wall mounting brackets & fitting. The job includes repairing the walls where necessary. Warrantee.:- 2 Years from the date of installation.
Supplying & fixing of M.S Wall/Floor Stand duly powder coated for outdoor unit of Split AC
Supplying & fixing of drain pipe for indoor unit 1"
Extra length of copper pipe for outdoor unit and suitable size copper cable of required size for 1.5 Ton AC
Extra length of copper pipe for outdoor unit and suitable size copper cable of required size for 2.0 Ton AC
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.57 MB
BOQ_973741.xls
BOQ • 0.38 MB