Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.8 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹20.5 L+₹3.5 L (20.5%)Rejected-AOC 499 A VIDHYUT NAGAR A AJMER ROAD JAIPUR 302021 | JAIPUR | JAIPUR | RAJASTHAN | 302021 | L2 | Rejected-AOC Other than lowest bidder | |
| 3 | L3₹20.7 L+₹3.7 L (21.8%)Rejected-AOC | L3 | Rejected-AOC Other than lowest bidder |
Tender Value
Refer Docs
EMD Value
₹44,500
Closing Date
18 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (S) Jaipur
Garrison Engineer (South) Military Engineer Services Kalyan Marg, Jaipur 302006
REPAIR AND MAINT OF INTERNAL FITTINGS AND FIXTURES AND WINTER APPLIANCES AND THEIR CONNECTED ITEMS AT NIWARU, JAIPUR MIL STN UNDER GE (SOUTH) JAIPUR
2020_MES_389359_1
GE (S)J-40P/2020-21 8595/ /E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Jaipur
Class E Category b (i)
9 documents required · 9 mandatory
₹500
GE (S) Jaipur
₹44,500
Yes
1 Dec 2020
23 Oct 2020
20 Nov 2020
23 Oct 2020
18 Nov 2020
6 Nov 2020
60 days
Amount
Taking down copper/aluminium point wiring(light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc and making good disturbed surfaces of walls, floors, etc.
M&L for point wiring complete with 1.5 Sqmm single core PVC insulated and unsheathed multi stranded copper conductor FRLS cable of 1100 V grade (ISI marked) PVC insulated and sheathed cable enclosed in and including pvc condut with all accessories ISI marked,concealed to walls/ ceiling all as per IS including hard wood board and 3 mm thick phenolic laminated sheet top cover fixed or suitable cover for mounting fitting like switches, sockets, fan regulators of piano/ modulor type etc. including 1.5 sqmm single core PVC insulated but unsheathed copper earth continuty conductor FRLS cable 1100 V grade (ISI marked) as continuous earth wire connected to common earth dolly complete all as sprcified and directed for followings :-.
One light/fan/ bell point controlled by one, one way switch
One 3 pin 5 Amp socket outlet on the same board with other switches
One 3 pin 5 Amp socket outlet on independent board with other switches
One 3 pin 5 Amp switch socket combination complete all as specified and directed.
All as per item No 2 above but Point wiring with 4 Sqmm copper cable for 3 pin 15 Amps socket outlet on independent board, including 4 Sqmm copper cable continuous earth wire and connecting to common earth dolly complete all as specified and directed.
M&L for point wiring complete with 1.5 Sqmm single core PVC insulated and unsheathed multi stranded copper conductor FRLS cable of 1100 V grade (ISI marked) PVC insulated and sheathed cable enclosed in and including pvc Casing and Caping with all accessories ISI marked, all as per IS including hard wood board and 3 mm thick phenolic laminated sheet top cover fixed or suitable cover for mounting fitting like switches, sockets, fan regulators of piano/ modulor type also etc. including 1.5 sqmm single core PVC insulated but unsheathed copper earth continuty conductor to common earth and connected FRLS cable 1100 V grade (ISI marked) as continuous earth wire to earth dolly compiete all as sprcified and ditected for followings :-.
One light/fan/ bell point controlled by one, one way switch
One light point controlled by two, two way switches
One 3 pin 5 Amp socket outlet on the same board with other switches
One 3 pin 5 Amp socket outlet on independent board with other switches
One 3 pin 5 Amp switch socket combination complete all as specified and directed.
All as per item No 4 above but Point wiring with 4 Sqmm copper cable pvc insulated unsheathed for 3/6 pin 15 Amps socket outlet on independent board, including 4 Sqmm copper cable pvc insulated unsheathed continuous earth wire and connecting to common earth dolly complete all as specified and directed.
S&F in repairs of switch, piano flush/ Bell push button type 230/250 volts ISI marked,complete all as speified and directed of following:- (Make- Anchor/Havells/ABB/Legrand)
Single pole , one way 5 Amp rating
Single pole, two way 5 Amp rating
Bell push, flush type 5 Amp rating
Single pole , one way 15/16 Amp rating
S&F switch, Modular/ Bell push type 230/250 volts ISI marked,complete all as specified and directed of following :-
One way 6 Amp rating switch (Make- ABB /anchor/Havells/Legrand)
One way 16 Amp rating switch (Make- ABB /anchor/Havells/Legrand)
Bell push, Modular type 6 Amp rating (Make- ABB /anchor/Havells/Legrand)
Supply & fixing Socket outlet multipurpose use, flush mounting, 230/250 Volts grade (ISI marked) on top covers complete all as specified and directed by Engineer in charge of following itmes 8.01 to 8.02 :- (Make- Anchor/Havells/ABB/Legrand)
5 pin 6 Amp
6 pin 16 Amp
6 pin 5/6 Amp switch socket combination along with back mounting box complete all as specified and directed.
S&F Socket outlet of Modular type multipurpose use, 230/250 Volts grade (ISI marked) on top covers complete all as specified and directed by Engineer in charge of following:-
(2+3) Pin 6 Amp Socket- CPW2065 (Make- ABB /anchor/Havells/Legrand)
6/16 Amp Socket- CPW2166 (Make- ABB /anchor/Havells/Legrand)
S & F in repair electric bell multi music type AC 230 volts single pole (ISI marked) for AC 230V, 50 Hz ding dong type complete all as specified and directed
S & F in repair lamp holder angle type insulated body with back plate for batten/pendant fitting complete all as specified and directed
S&F in repair Ceiling rose, 3 Phase/ PVC/ Polycarbonate isolated body complete all as specified and directed by Engr-in-charge.(Make:- Anchor/ Havells/Polycab)
S&F in repairs of 3mm thick laminated sheet top cover (ISI marked) cut to suitable size and making arrangement for mounting switch, socket,regulator,etc. as all as specified and directed by Engr-in-charge.
S&F in repair Energy efficient LED building lights of 30 Wattage with PDC Aluminium body and clear glass, LED lens for wide beam distribution with efficacy greater than 100 Lm/watt , 5700K CCT, pf more than .90 all as specified and directed by Engr-in-charge. Make - Polycab cat Pt No- PCGLS T1 30L or equivalent of Havells, Bajaj, Philips
S&F in repairs Globe shaped post top lantern in frosted finish made up of Polycarbonate, long life aesthetically designed with systematic light distribution with IP 65 with 40 Watt LED Bulb and 5700 K lumen complete all as specified and directed. Havells cat No.- LHEVBGP7PN6K040 or equivalent in Bajaj, POLYCAB, Philips
S&F in repairs Bulk Head light environfriendly ultra modern energy saving surface mounted decorativeoval bulk head edge lit LED luminaire comprising of High brightness LED Lamp. Make- Havells cat pt- LHEOAOP7UZ6W010 with HSN code- 9405 or equivalent in Bajaj, POLYCAB, Philips
S&F in repairs globe Light including LED Bulb and Base Holder made of Glass/Polycarbonate for decorative wall light fixture (Havells item code- LHDL06160099) or equivalent model in crompton/ bajaj/surya.
S&F in repairs globe Light Glass/Polycarbonate for decorative wall light fixture (Havells item code- LHDL06160099) or equivalent model in crompton/ bajaj/surya.
S&F in repairs Aesthetically designed energy saving LED Endura lighting fitting round in shape of 15 Wattage having white powder coated CRCA housing and PS diffuser of 4000K- 6100K CCT as per old U/S existing fittings & all as specified and directed by Engr-in-charge. Havells: LHEAAGP7IA2W012 or equivalent of Havells, Bajaj, Philips etc.
S&F in repairs Energy saving environmental friendly, LED Batten Tube Light fittings 18/20/22 Watt ,1200mm(4 feet) TL, long life, impact proof,surface/wall mounting IP20,100 Lm per Watt, extruded Thermoplastic body with PC diffuser greater than 120 degree wide distribution available in 6500K CCT with high brightness LEDs complete with all accessories pre-wired twin core twisted flexible copper conductor cable with suitable size complete including dismantling of old existing unserviceable fluorescent/LED TL & all as specified and directed by Engr-in-charge. Make -POLYCAB or equivalent of SYSKA, Crompton Greaves,Havells, Bajaj,philips,Halonix
S&F in repairs Energy saving environmental friendly, LED Batten Tube Light fittings 10/12 Watt ,600mm(2 feet) TL, long life, impact proof,surface/wall mounting IP20,100 luminaire per Watt, extruded Thermoplastic body with PC diffuser greater than 120 degree wide distribution available in 6500K CCT with high brightness LEDs complete with all accessories pre-wired twin core twisted flexible copper conductor cable with suitable size complete including dismantling of old existing unserviceable fluorescent/LED TL & all as specified and directed by Engr-in-charge. Make -POLYCAB or equivalent of SYSKA, Crompton Greaves,Havells,Bajaj,philips,Halonix
S&F in repairs False ceiling light LED slim panel of size 2ft x 2ft fitting of 40/42 Wattage having white powder coated extruded aluminium body with high quality LGP and PMMA diffuser suitable for Armstring/ Grid ceiling of 6000K CCT & all as specified and directed by Engr-in-charge. Make - Polycab cat Pt No- PCGLP ECO 2X2 40 60 with product code PMD0401018 or equivalent of Havells Cat No.- LHEWDRP6PK1W042, Bajaj, Philips etc.
M&L for taking down sub main wiring of copper with PVC/steel conduit complete all as specified and directed.
M & L for Sub main wiring with 02 runs of 6 Sqmm single core FRLS PVC insulated unsheathed multi stranded copper conductor cable 1100 volts grade (ISI marked) drawn through and including 25mm dia PVC rigid conduit medium with conduit accessories and fixed to the surface of wall/ceiling as per ISI including 01 run of 6 Sqmm PVC insulated copper conductor earth continuity wire coplete all as specified and directed. Note : Two runs of copper conducter and one run of earth copper conducter and one run of PVC conduit shall be measured as one length. Make : Finolex/Nicco/L&T /Richa cables pvt ltd/plaza/paragon/polycab/havells
M & L for Sub main wiring with 04 runs of 6 Sqmm single core FRLS PVC insulated unsheathed multi stranded copper conductor cable 1100 volts grade (ISI marked) drawn through and including of 25mm dia PVC rigid conduit medium with conduit accessories and fixed to the surface of wall/ceiling as per ISI including 02 runs of 6 Sqmm PVC insulated copper conductor earth continuity wire coplete all as specified and directed. Note :Four runs of copper conducter and Two run of earth copper conducter and one run of PVC conduit shall be measured as one length. Make : Finolex/Nicco/L&T /Richa cables pvt ltd/plaza/paragon/polycab/havells
M&L for taking down unserviceable DBs /Sheet Metal Enclosures of any type disconnecting carefully and making good disturbed surfaces complete all as directed.
S & F sheet metal enclosure MCB DB 4 way SPN double door suitable for 240 V with and including 100 to 200 amps rated copper bus bar fixed/ flused on walls including cutting Knitch and making good disturbed surfaces complete all as specified and directed. Make - hager/polycab/havells/ ABB/ Anchor
S & F sheet metal enclosure MCB DB 8 way SPN double door suitable for 240 V with and including 100 to 200 amps rated copper bus bar fixed/ flused on walls including cutting Knitch and making good disturbed surfaces complete all as specified and directed. Make - hager/polycab/havells/ABB/ Anchor
S & F sheet metal enclosure MCB DB 12 way SPN double door suitable for 240 V with and including 100 to 200 amps rated copper bus bar fixed/ flused on walls including cutting Knitch and making good disturbed surfaces complete all as specified and directed. Make - hager/polycab/havells/ABB/ Anchor
S & F sheet metal enclosure MCB DB 4 way TPN double door suitable for 415 V(with out MCB) with and including copper bus bar fixed flused on walls including cutting Knitch and making good disturbed surfaces complete all as specified and directed. Make - hager/polycab/havells/ ABB/ Anchor
S & F in repair C-Curve MCB single pole (SP) 240 volt 06-32 amp,10 KA, ISI marked, for inductive load connected through cable lugs of switable size complete all as specified and directed. Make - Legrand/schneider/hager/polycab/havells
S & F in repair MCB single pole neutral(SPN) 40 Amps,10 KA, ISI marked, for inductive load connected through cable lugs of suitable size complete all as specified and directed . Make - Legrand/schneider/hager/polycab/havells
S & F in repair MCB Tripple pole neutral(TPN) 63 Amps,10 KA, ISI marked, for inductive load connected through cable lugs of suitable size complete all as specified and directed . Make: Legrand/ Schneifder/ Hager/ Polycab/ Havells
S & F in repair modular switch board of different module(5/6/7/8/9 module) with proper nut bolt and suitable for existing modular socket and switches complete all as specified and directed by engr- in- charge.
M&L for earthing complete as per electrical plate No. 3 of MES SSR Part-I with galvanised steel earth plate electrode 60cmx60cmx6.0 mm thick, buried directly vertically in ground in a pit depth not less than 2.5 metres below ground level with top edge of earth plate at a depth not less then 1.8 metre below normal ground level connected to and including galvanised iron or steel earth wire 4 mm dia by means of bolts, nuts check nuts and washers of galvanised iron or steel. Earthing wire shall be protected by galvanised iron or steel pipe 15 mm bore medium grade and connected to continuous earth wire on pole / test point to main board. Watering pipe shall be 20 mm bore GI medium grade. The earthing shall be of inclusive of excavation & earth work in any type of soil, charcoal, salt, funnel PCC pit and RCC cover complete all as specified & directed as well as testing included. Note 1-: Following items deemed to be included in quoted rate (a) Earth Electrode (b) Main earthing lead from earth electrode to test point and further to equipment to be earthed upto 7.5 metre (c) M&L for connecting earth electrode and earthing lead as specified (d) Adequate quantity of charcol dust and common salt as directed (e) All labour involved including testing of earth net work (f) Excavation and earth work or drilling hole for electrode (g) P.C.C pit and C.I cover (h) Funnel and watering pipe, wire mesh and copper lugs etc. as specified (j) G.I protection pipe of size ordered specified for protection of earthing lead from mechanical injury or tempering. (k) connected lead from test point to main switch or switch board or equipment to be earthed. Note 2-: In case, after completion if the desired earth resistance is not obtained on testing then, the earthing will be redone at no extra cost.
S&F in replacement of old u/s flameproof T/L with blue alluminium die cast Lm6 flameproof led tubelight 20 Watt IP 66, cool white color, color temperature 6500K, T8 type base, ISI marked complete all as specified and directed.
Geyser Taking down carefully after disconnecting electrical/water supply connections and transporting to the work shop to carry out the servicing / over hauling of the storage type electric water heaters (Geysers) of storage capacity 25 litres of any make / type by cleaing the inner surface of the tank / heating element with chemical to remove the scaling / rust & reassembling the same , required brazing/soldering refixing on its original position including reconnecting only testing complete all as specified and directed.
S&F in repair of heating assembly with its base plate circular in shape including rubber washer / nuts/ bolts/ packing material, heating element of capacity 2 KW (ISI marked) as per existing make of geyser -Venus model no. 25GVM/2015 etc all complete. Make: kawai 230 volt, 2000 watt 1503 VenusVenus/ Bajaj /Theeta/Swarna or eqivalent ISI marked Note- item supplied will be as per existing and as directed by engineer in charge
S&F in repair Capillary thermostat with relay/ switch (15Amp 250 Volts) with inbuilt nobe for temp variation as per existing sample suitable for 25 litres capacity Geysers.
S&F in repair thermal-cutout with heating sensor rod (capillary type) relay/contactor (model T100 20Amp 250 Volts) as per existing sample suitable for 25 litres capacity Geysers.
S&F in repair neon indicator lamp round or rectangular type (ISI marked) complete all as specified and directed.
S&F in repair Pressure release safety valve for Geysers spring loaded suitable for 15mm pipe chromium plated (ISI marked) complete all as specified and directed.
S&F in repair flexible copper wire PVC insulated, 3 core, 2.5 Sqmm dia multistranded complete as specified and as directed.
M&L for replacement of old U/S Chromium plated stainless steel pipe connection for cold water inlet/ hot water outlet pipe of size 15mm dia complete with nipple/adaptors 450mm long (ISI marked) .
M&L for replacement of old U/S PVC connection pipe threaded type for cold water inlet/ hot water outlet pipe of size 15mm dia complete with nipple/adaptors 450mm long (ISI marked) make- prayag/polytuf
SOLAR WATER HEATER Descaling of Solar Collectors plate connected to solar water heater of various capacity (by circulating descaling solution/agent for 20-30 min.) cleaning entire surface (dismantaling of plates shall be carried out if required, including fixing, soldering if required) and cleaning of tank of capacity 100/200/300/400 LPD by solar descaling (such as mild acidic solution/agent including drain out all scales, dust dirt by pressure pipe cleaning & replacemen of U/S drain plug along with all required work such as welding, threading, etc all as specified and directed.
S&F in repair Evacuated tube collector type 100 LPD solar water heater (MNRE) approved along with GI storage tank of suitable capacity on iron angle applying water sealant around stand fasteners including dismanaling of old unserviceable solar water heater complete all as specified and directed.
S&F in repair Evacuated tube collector type 200 LPD solar water heater (MNRE) approved along with GI storage tank of suitable capacity on iron angle applying water sealant around stand fasteners including dismanaling of old unserviceable solar water heater complete all as specified and directed.
S&F in repair Evacuated tube collector type 300 LPD solar water heater (MNRE) approved along with GI storage tank of suitable capacity on iron angle applying water sealant around stand fasteners including dismanaling of old unserviceable solar water heater complete all as specified and directed.
S&F in replacement of old unserviceable water tank of flat plate solar water heater/ Evacuated tube solar water heater of capacity 100/200/300/400 LPD along with all connecting items like nut bolts gasket soldering welding etc complele all as specified and directed.
M&L for cladding of insulated rubber (rock wool/ mineral wool/ fibre glass wool) as per fixed on site including one layer of aluminium sheet/ flakes cover on outlet/ air vent of solar water heater GI pipe in a manner to minimise any type of heat losses complete all as specified and directed by engineer in charge.
S&F in replacement of Unserviceable forged brass ball valve screwed of size 20mm dia. Make: Leader/ Kirloskar/ L&T/ Zoloto
S&F in replacement of Unserviceable Gate valve of size 20mm dia. Make: Leader/ Kirloskar/ L&T/ Zoloto
S&F in repair unserviceable EPDM sheet including required nut, bolt and washer set at both end , used for jointing two flat plate collector/ at end of solar flat plate collector or connection of tubes in evacuated tube solar water heater complete all as specified and directed.
S&F in replacement heating element 3000 watt alongwith thermostat of suitable shape and size fitted in Solar water heater tank, conforming to ISI with rubber washers, with clamps all as specified and directed by Engr-in-charge. Make- Thermoking/Hottop other ISI make as approved by GE.
S&F in replacement U/S stem type thermostat with switch/nob suitable for Solar water heater all as specified and directed by Engineer - in - Charge. Make : Bajaj, Spherehot, Racold / other ISI make as approved by GE.
S&F in replacement GI tubing, medium grade in short lengths with all fittings such as elbow, tee, socket, nipple, reducing socket, reducing elbow, reducing tee including guttees / saddles etc of size 20 mm bore and fixed to wall / floor / ceiling including connection to mixing arrangements of hot / cold water and making good disturbed surfaces all as specified and directed by Engineer - in – Charge. Make : Jindal / Prakash / Surya.
M&L for fixing only serviceable FPC solar plates retrieved from item no. 47,48,49 including all nuts washers suitable flexible rubber/ silicon hose pipes welding etc including dismantalling of existing non functional FPC solar heater complete all as specified and directed.
S&F in replacement Unserviceable Plug and socket board with metal plug and socket (1 phase+neutral & earth) of 20 Amp rating DP of make- Polycab with item code GPDPS10004 in accordance with IS 13032, IS 8623, IEC/BSEN 61439-3.
S&F in repair SP MCB ranging from 6 to 32 Amp B-Curve type 240 Volt, 50 Hz AC supply with breaking capacity of 10 KA in accordance with IS/ IEC 60898-1 of Make- Polycab/Legrand/ABB/Havells/other equivalent approved make.
M&L for replacement of MS Cross arms, bracings, supports,clamps and back plates fabricated from structural steel sections including nuts, bolts, washers,welding, bending cold or hot,drilling holes for bolts, in any shape or size as indicated or directed and provn of two coat of systhic enamed pait over a coat of red oxide primer complete primer all as specified and directed by Engr-in-charge.
M&L for Providing precast cement concrete set in cement mortar (1:2:4) type B1 using 20mm graded aggregates for stand of solar water heater and set in CM (1:6) complete all as specified and directed.
M&L for earthing complete as per electrical plate No. 5 of MES SSR Part-I with galvanised steel earth plate electrode 60cmx60cmx6.0 mm thick, buried directly vertically in ground in a pit depth not less than 2.5 metres below ground level with top edge of earth plate at a depth not less then 1.8 metre below normal ground level connected to and including galvanised iron or steel earth Galvanised iron strip 32x6 mm as earthing lead by means of bolts, nuts check nuts and washers of galvanised iron or steel. Earthing galvanised iron strip shall be protected by galvanised iron or steel pipe 40 mm bore medium grade and connected to continuous earth wire on pole / test point to main board. Watering pipe shall be 20 mm bore GI medium grade. The earthing shall be of inclusive of excavation & earth work in any type of soil/PCC/Rocky soil, charcoal, salt, funnel PCC pit and RCC cover complete all as specified & directed as well as testing included. Note 1-: Following items deemed to be included in quoted rate (a) Earth Electrode (b) Main earthing lead from earth electrode to test point and further to equipment to be earthed upto 7.5 metre (c) M&L for connecting earth electrode and earthing lead as specified (d) Adequate quantity of charcol dust and common salt as directed (e) All labour involved including testing of earth net work (f) Excavation and earth work or drilling hole for electrode (g) P.C.C pit and C.I cover (h) Funnel and watering pipe, wire mesh and copper lugs etc. as specified (j) G.I protection pipe of size oredered specified for protection of earthing lead from mechanical injury or tempering. (k) connected lead from test point to main switch or switch board or equipment to be earthed. Note 2-: In case, after completion if the desired earth resistance is not obtained on testing then, the earthing will be redone at no extra cost.
M&Lfor fixing only serviceable FPC solar water heater tank of different capacities retrieved from item no. 47, 48 and 49 including all nuts washers suitable flexible rubber/ silicon hose pipes welding etc including dismantalling of existing non functional FPC solar heater complete all as specified and directed.
DIVYA ASSOCIATES
J.J.ENGINEERING
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .