Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.9 LAccepted-AOC NO 6 G 2 SS ENCLAVE 1ST MAIN 1ST CROSS INDIAN EXPRESS LAYOUT VIRUPAKSHAPURA VIDYARANYAPURA POST BANGALORE 560 097 | BENGALURU URBAN | KARNATAKA | 560097 | L1 | Accepted-AOC AOC | |
| 2 | L2₹31.2 L+₹2.9 L (10.2%)Rejected-Finance NO 1 1ST MAIN ANANDNAGAR ATRIA INSTITUTE OF TECHNOLOGY CAMPUS HEBBAL BANGALURU 560 024 | BENGALURU URBAN | KARNATAKA | 560024 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹33.3 L+₹5.0 L (17.8%)Rejected-Finance | L3 | Rejected-Finance Not Lowest |
| Sl No | Description | Qty | Unit | Eeguchi Constructions L2 | VIKAS CONSTRUCTIONS L1 | C-Will Engineers & Architects L3 |
|---|---|---|---|---|---|---|
| 1.00 | Taking down of existing Water Proofing treatment of any type (APP Membrane,Cement or earthen tile,Mud phuska or lime concrete) including cement plaster of any thickness and removing bitumen coating/mud pushka dirtsetc over original RCC roof slab by grinding, Picking, sweeping clean and washing down with water to remove dust & to providing water prooling treatment complete.
Note : Rate includes for removing debris outside defence land | 320 | SQUARE METRE | 70 ₹22,400 Lowest | 80 ₹25,600 | 100 ₹32,000 |
| 2.00 | M & L for demolition & removal of cement concrete/padding concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
Note : Rate includes for removing debris outside defence land | 12.16 | CUBIC METRE | 580 ₹7,052.8 | 650 ₹7,904 | 500 ₹6,080 Lowest |
| 3.00 | M&L providing cement concrete type B0 1:2:4 (12.50mm graded stone aggregate) in copings, parapets and railing upto 60cm height, leveling concrete for Roof slab, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed. | 12.16 | CUBIC METRE | 6,500 ₹79,040 | 5,950 ₹72,352 Lowest | 6,500 ₹79,040 |
| 4.00 | M & L for providing screed bed/rendering 10mm thick in CM (1:3) mixed with and including supply of approved water proofing compound as per manufacturers instructions by removing all loose gravel, dirt, oil, grease and foreign materials by jet or dry air, cleaning the surfaces mechanically or by grinding to make it smooth and applying APP modified water proofing membrane as per IS 1654-2017/IS 16352-2017 , 3mm thick and weighing not less than 3.60kg/Sq m reinforced with non woven polyster/HMHDPE matt black finished over compatible primer/bonding bitumen @ 0.40 Litre/Sq m and torch applications of membrane with 75mm side overlap and 100mm end lap after necessary preparation of surface complete as per manufacturer's instructions and applying a coat of solar reflective bituminous aluminum paint on top @ 0.10 litre/sq m complete all as specified and directed. | 320 | SQUARE METRE | 650 ₹2,08,000 | 580 ₹1,85,600 Lowest | 580 ₹1,85,600 Lowest |
| 5.00 | M & L for 500 litres capacity rotational moulded, triple layer polythene water storage tanks (cylindrical vertical with closed top) hoisting and fixed in position on roofs including 25 mm dia ball valve and (2 No.25 & 1 No.20 ) mm dia nipple including dismantling existing water storage tank, complete all as specified. | 8 | EACH | 6,200 ₹49,600 | 4,500 ₹36,000 Lowest | 6,500 ₹52,000 |
| 6.00 | Supply & laying 20 mm outer dia CPVC pipes SDR 11 (Plain CPVC SDR 11 fittings on walls / ceiling or laying in floors including all fittings and specials including taking down 15 mm GI tubing and connections complete all as specified. | 180 | RUNNING METRE | 300 ₹54,000 | 280 ₹50,400 Lowest | 300 ₹54,000 |
| 7.00 | Supply & laying 25 mm outer dia CPVC pipes SDR 11 (Plain CPVC SDR 11 fittings on walls / ceiling or laying in floors including all fittings and specials including taking down 20 mm GI tubing and connections complete all as specified. | 50 | RUNNING METRE | 320 ₹16,000 Lowest | 380 ₹19,000 | 370 ₹18,500 |
| 8.00 | S&F in repairs 20mm CPVC gate valves, with lever, screwed both ends for iron pipe and fixed | 8 | EACH | 400 ₹3,200 Lowest | 450 ₹3,600 | 550 ₹4,400 |
| 9.00 | S&F in repairs 25mm CPVC gate valves, with lever, screwed both ends for iron pipe and fixed | 8 | EACH | 450 ₹3,600 Lowest | 650 ₹5,200 | 650 ₹5,200 |
| 10.00 | Taking down chowkhat (without taking of shutter from the frame) not exc 1.5 sqm each including making good the disturbed surface in PCC 1:2:4 type B0 or CM 1:3 all as specified and directed | 32 | EACH | 250 ₹8,000 | 180 ₹5,760 Lowest | 200 ₹6,400 |
Tender Value
₹36.5 L
EMD Value
₹73,000
Closing Date
18 Feb 2026, 6:00 pmClosed
GE North Bangalore
GARRISON ENGINEER NORTH BANGALORE T 64 MEANEE LINESMEG AND CENTRE BANGALORE 560042
SPECIAL REPAIRS BR TO BUILDING NO P2 IN NAVAL DETACHMENT UNDER GE NORTH BANGALORE
2026_MES_750202_1
8288
Open Tender
Civil Works
Item Rate
180 days
Bangalore
Class D Category a(i)
7 documents required · 7 mandatory
₹500
Yes
GARRISON ENGINEER
₹73,000
Yes
23 Jun 2026
28 Jan 2026
20 Feb 2026
28 Jan 2026
18 Feb 2026
11 Feb 2026
28 Jan 2026 - 11 Feb 2026
Taking down of existing Water Proofing treatment of any type (APP Membrane,Cement or earthen tile,Mud phuska or lime concrete) including cement plaster of any thickness and removing bitumen coating/mud pushka dirtsetc over original RCC roof slab by grinding, Picking, sweeping clean and washing down with water to remove dust & to providing water prooling treatment complete. Note : Rate includes for removing debris outside defence land
M & L for demolition & removal of cement concrete/padding concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed. Note : Rate includes for removing debris outside defence land
M&L providing cement concrete type B0 1:2:4 (12.50mm graded stone aggregate) in copings, parapets and railing upto 60cm height, leveling concrete for Roof slab, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed.
M & L for providing screed bed/rendering 10mm thick in CM (1:3) mixed with and including supply of approved water proofing compound as per manufacturers instructions by removing all loose gravel, dirt, oil, grease and foreign materials by jet or dry air, cleaning the surfaces mechanically or by grinding to make it smooth and applying APP modified water proofing membrane as per IS 1654-2017/IS 16352-2017 , 3mm thick and weighing not less than 3.60kg/Sq m reinforced with non woven polyster/HMHDPE matt black finished over compatible primer/bonding bitumen @ 0.40 Litre/Sq m and torch applications of membrane with 75mm side overlap and 100mm end lap after necessary preparation of surface complete as per manufacturer's instructions and applying a coat of solar reflective bituminous aluminum paint on top @ 0.10 litre/sq m complete all as specified and directed.
M & L for 500 litres capacity rotational moulded, triple layer polythene water storage tanks (cylindrical vertical with closed top) hoisting and fixed in position on roofs including 25 mm dia ball valve and (2 No.25 & 1 No.20 ) mm dia nipple including dismantling existing water storage tank, complete all as specified.
Supply & laying 20 mm outer dia CPVC pipes SDR 11 (Plain CPVC SDR 11 fittings on walls / ceiling or laying in floors including all fittings and specials including taking down 15 mm GI tubing and connections complete all as specified.
Supply & laying 25 mm outer dia CPVC pipes SDR 11 (Plain CPVC SDR 11 fittings on walls / ceiling or laying in floors including all fittings and specials including taking down 20 mm GI tubing and connections complete all as specified.
S&F in repairs 20mm CPVC gate valves, with lever, screwed both ends for iron pipe and fixed
S&F in repairs 25mm CPVC gate valves, with lever, screwed both ends for iron pipe and fixed
Taking down chowkhat (without taking of shutter from the frame) not exc 1.5 sqm each including making good the disturbed surface in PCC 1:2:4 type B0 or CM 1:3 all as specified and directed
All as per Item No 10 above, but exc 1.50 sqm and not exc 4.00 sqm each
Supply and fixed PVC door frame of size 50mm X 47mm made out of 5mm thick plain colour PVC sheet reinforced with MS square tube. Fixing in opening as per specification .
M & L for Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing with wood free EPS .
S&F 2nd class hard wood plain, solid, straight chowkats and frames, clean sawn, frame rebeated on the solid, rounded or chamfered, put tegether with glue pinned at joints etc complete all as specified and as directed
S&F for mild steel work as in hold fast made in flat iron all as specified.
S&F 2nd class hard wood 35 mm thick made glazed and skeleton shutters open rebated and prepared to receive glass, gauze,etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass,etc, size of members of shutters as spfd in SSR Part-1, Section 8, clause 8.24 (a) kiln seasoned and chemically pressure treated complete all as specified and as directed Note: Supply & fixing of 4 mm thick sheet glass or wire mesh be measured and paid separately.
S & F Plain framed, panelled shutter (two panel) of 35mm thick with lock rail and panel of 9mm BWP commercial ply or 12mm venereed particle board with commercial veneering on both faces. rail and style are of 2nd class hardwood & The size of rail and stile as per IS:1003 (Part-I), kiln seasoned and chemically pressure treateds fixed to chowkhat all as specified and as directed.
M & L for powder coated (minimum thickness of powder coating 50 micron) aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified )
M & L Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge. Note: Supply & fixing of 4 mm thick sheet glass or wire mesh be measured and paid separately.
S&F Anodised aluminum powder coated (of any shade/colour as approved by GE ) ventilators with adjustable 4mm thick figured glass louvers, fixed in half portion, without sash bars, aluminum section weighing 0.55 kg/m including necessary jointing cleats, glazing clips, rubber packing, anodised aluminum snap beading, screws, including stainless steel wire cloth 0.36 nominal dia of wire and average width of aperture 1.18mm including complete etc all as specified and directed by the Engineer-in-charge (Size of Ventilators = 600x900 mm)
M & L for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165
Supply & fix Sheet glass 4mm thick ordinary quality and glazing with oil putty or in wooden / steel /aluminium /rubber beading in square not exceeding 0.5 Sqm in each pane and all as specified.
Supply & fix Sheet glass 4mm thick ordinary quality and glazing with oil or in wooden /steel /aluminium /rubber beadingputty in square exceeding 0.5 Sqm in each pane and all as specified.
Supply & fix stainless steel wire cloth 0.36mm nominal dia and average width of aperture 1.40mm and fixed with tinned tack or galvanized wire staple all as directed fixed.
M&L preparing new wooden surface of any description, not other wise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer etc complete all as specified and as directed
Dismantling wrought iron or mild steel work of any description not otherwise provided for
M&L for rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling of sheet of any type and any thickness complete all as specified and directed.
M & L applying two coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces over 10 cm width or girth including preparation of new steel surfaces
S & F Butt hinges stainless steel 100mm long and fixed to door frame and shutter duly welded/screwed complete all as specified and as directed
S & F Butt hinges medium weight, cold rolled mild steel 100mm long and fixed to door frame and shutter duly welded/screwed complete all as specified and as directed
S&F Aluminium anodised tower bolt 150mm long of extruded section etc complete all as specified and as directed
S&F Aluminium anodised tower bolt 200 mm long of extruded section etc complete all as specified and as directed
S&F 125 mm long aluminium handle, cast type, anodised etc complete all as specified and as directed
S&F 150 mm long aluminium handle, cast type, anodised etc complete all as specified and as directed
S&F aluminium alloy, anodised sliding door bolt 300 mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy etc complete all as specified and as directed
S & F 140 mm floor door stopper of aluminium alloy powder coated, with hard down steel spring all as specified and as directed.
S&F mild steel 300mm, ordinary rat tail rod pattern springs, including roller and roller plate complete
S & F in repairs 18/19mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work,alround 6mm th teak fillets fixed in kitchen Cabinet or cupboards all as specified.
M&L for Plain fillets square, rectangular or triangular in section clean sawn , secured with nails or brads of second class hard wood fixed to cupboard shutter including taking down old fillets exc 13 & n exc 25 sqcm cross section area all as specified and directed.
S&F Continuous (piano) hinges 30mm width of flaps (when open), mild steel, bright finish or electro galvanised
S&F 100 mm size hasp and staple, safety type, aluminium anodized with mild steel hinge pin including bolt to hinge plate and fixed with screws / fixed in repairs.
S&F Magntet door catcher made of main body magnet of stainless steel including iron striking plate of size 60x30x10 mm in size complete all as specified and directed
S & F 40 mm dia cupboard knobs fixed with nut, screw and washer of Brass,polished complete all as specified and as directed.
S&F in repairs stainless steel decorative curtain rod of 20 mm bore with wood finishes (weight not less 300 gms per running meter) incl fancy finale caps cap etc complete all as specified and as directed
S&F in repair Bracket for curtain rod of dia 20 mm dia made out of SS Flat not less than 20 mm wide 1.50 mm thick and overall length not less than 160 mm fixed with screws min 2 Nos with Rawl Plug of size not less than 50 mm long incl wooden base etc complete all as specified and as directed
M & L for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms, urinal partition and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite ,including cutting and polishing laid on 15 mm thick screed bed in CM 1:4 set and jointed including dismantling of old stone slabs laid bedded and pointed in any mortar complete all as specified
M & L for Providing edge moulding to 18-20mm thick granite stone any description of counters vanities etc. including machine polishing to edge to give high gloss finish etc. complete
S&F in repair Vitreous China wash basin, white, flat back, size 550x400mm including 32 mm dia brass waste coupling ,15 mm dia chromium plated fancy type pillar taps, waste pipe, 600 mm long PVC connection & brackets including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing & supply and waste pipe.complete all as specified and as directed
S&F in repair Vitreous china wash down water closet pan (pedestral Pattern) white, (Including flushing cistern and flush pipe) , including connection to drain & or out going pipe) and to flushing pipe, anti syphonage pipe, seat and cover for pedestral pan including PVC flushing cistern and 450 mm long PVC connection etc. complete all as specified and as directed
S&F 15mm stop valves / angle valves cast copper alloy, screwed down, high pressure, fancy type, chromium plated screwed both ends for iron pipe or for unions and fixed in repairs.
S&F 15mm stop valves cast copper alloy, screwed down, high pressure, fancy type, chromium plated with long shank and cup (concealed type) screwed both ends for iron pipe or for unions and fixed in repairs.complete all as specified and as directed
S&F in repairs Brass CP wall mixer for mixing hot and cold water screwed down for iron pipe and fixed complete all as specified and directed.
S & F chromium plated long body bib tap 15mm dia with CP flange as fixed in repair all as specified and as directed.
S&F in repair chromium plated 15mm dia with CP flange two way bib cock with angle valve combination all as specified and as directed.
S & F in repairs Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position in all respect as specified.
S & F in repairs Towel rail stainless steel glossy finish, D type 20 mm dia and 600 mm long complete all as specified and as directed.
S & F in repairs Towel ring stainless steel glossy finish, circular type minimum 5mm thick and 15 cm dia complete all as specified and as directed.
S&F in repairs Soap dish chromium plated brass all as fixed in wall as per manufacturers instruction.
S & F in repair 75mm dia PVC (SWR) floor trap, plain with grating including jointing with slvent cement all as specified and as directed.
Demolition of brick work or stone / boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
M&L for Pre-cast cement concrete block masonry, type C1 1:3:6 (using 20mm graded stone aggregate) in CM 1:6 with solid blocks,exc 10cm in width and setting in mortar, complete all as specified and directed.
Demolition of cement concrete and paving not exc 15 cm thick (below or above ground level) complete all as specified and as directed.
M & L cement concrete type B0 1:2:4 (12.5 mm graded stone aggregate) 25mm thick finished even as in levelling concrete for floor complete all as specified and as directed.
Dismantling of floor, hearth or wall tilling incl cement mortar bedding (but not backing) and removing rubbish off from premises.
M&L Non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.06 sqm but n.exc 0.11 sqm,in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, over 20mm thick screed bed of CM 1:4 etc. complete as specified and directed.
M&L Non Skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and incl Screed bed or bedding layer of mortar 20 mm thick in CM 1:4 for laying floor finishes all as specified and as directed.
M & L Glazed ceramic tiles in vertical surfaces 350 x 250x 7 mm/ 450 x 350 x 7 mm/ 300x450x7 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over & incl 10mm thick in screed CM 1:3 on brick work or concrete surfaces to receive wall tiles all as specified and as directed.
Taking down cement plaster of any description including racking out joints, hacking for key and disposal of debris to out side MD land all as specified and as directed.
M&L for Rendering 15mm thick in CM 1:6 on brick or concrete surfaces , finished even and smooth with out using extra cement. (Internal Surfaces)
M&L for rendering 15 mm thick on other than fair faces of brick work or concrete surfaces in cement mortar 1:4 with WPC, finished plastered surface even and smooth without using extra cement (External Surfaces) Note :- WPC will be measured and paid separately
Supply only water proofing compound (Liquid) complete all as specified and as directed.
M&L for Rendering 5 mm thick in CM 1:3 on ceiling surfaces, finished even and smooth with out using extra cement.
Preparation of new plastered surfaces and applying three coats of white wash on ceilings including in narrow widths/ bands etc complete all specified and as directed.
M & L for Preparation of newly plastered surfaces of wall/chajjas etc and applying two coats of Anti fungal weather proof grade exterior acrylic emulsion paint of approved tint (Apex Ultima or equivalent brand as specified in CA) over a coat of weather proof primer including filling the minor racks etc with crack filling material all as per manufacturers instructions complete all as specified and as directed.
M & L for Preparation of newly plastered surfaces and applying two coats of oil emulsion distemper over one coat of primer over one coat of 3 mm thick wall care putty on plastered surfaces of walls including in narrow widths/ bands etc complete all specified and as directed.
M & L for Complete removal of existing treatment on ceiling of any description over 10cm girth or width and applying three coats of white wash on ceilings including in narrow widths/ bands etc complete all specified and as directed.
M & L for Complete removal of existing treatment on wall surfaces chajjas etc of any description including brooming down with steel wire brushing, scrapping down smoke soot's , moulds, moss and efflorescence, salts, trading oil and greasy spots etc and applying two coats of Anti fungal weather proof grade exterior acrylic emulsion paint of approved tint (Apex Ultima or equivalent brand as specified in CA) over a coat of weather proof primer including filling the minor racks etc with crack filling material all as per manufacturers instructions complete all as specified and as directed.
M & L for Complete removal of existing treatment on walls of any description over 10cm girth or width and applying two coats of oil emulsion distemper over one coat of alkali resistant primer over one coat of 3 mm thick wall care putty on plastered surfaces of walls including in narrow widths/ bands etc complete all specified and as directed.
S & F in repair 75 mm dia bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/ floors including necessary fittings all as specified and as directed.
All as per item No. 79 but 110 mm dia .
S&F in repair 75mm dia PVC (SWR) Bends with access door of any radious
All as per item No. 81 but 110mm dia
S&F in repair 75mm dia PVC (SWR)branch piece, double (double Y) equal or unequal with access door
All as per item No. 83 but 110mm dia
M&L for PCC 1:3:6, type C2,(Using 40 mm graded stone aggregate), 75mm thick as in plinth protection/Sub base flooring, finishing surface fair and even, in panels & filling joints with mortar, etc., complete all as specified and directed.
Dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar complete all as specified and as directed by Engr-in-Charge
M & L providing 75 mm thick cement concrete 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in subbase / plinth protection.
M&L for chequered cement concrete tiles 300 x 300mm x 25mm thick, set, jointed and pointed in neat cement slurry with grey pigment cement and pigment, including Screed bedding layer in cement mortar 1:6, 20mm thick, in flooring, complete all as specified and as directed .
Dismantling of stone slabs and tiles laid dry or laid dry and pointed of any description or thickness in floors, aprons etc.
M & L providing 100mm thick cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in subbase.
Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand;etc complete all as specified and directed.
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
M&L for Pre-cast cement concrete block masonry, type C1 1:3:6 (using 20mm graded stone aggregate) in CM 1:6 with solid blocks,exc 10cm in width and setting in mortar, complete.
M&L for rendering 15mm thick in CM 1:6 on other than fair faces of brick work or concrete surface finished even and smooth with out using extra cement complete all as specified and directed
M&L for preparing new plastered surface of wall and applying three coat of white wash etc complete all as specified and as directed
Demolition and breaking up drain pipe (salt glazed ware, AC or reinforced concrete ) set in cement mortor for 150 mm internal dia of pipe complete all as specified and directed.
M&L for cement concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid & tested for 150 mm bore of pipe with cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate complete all as specified and directed.
M&L for laying DWCP 150 mm dia pipes in trenches Class SN-4 conforming to IS 16098 (Part -2) in 6 mtr length with coupler complete all as specified and directed by Engr-in-charge
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
M&L for Pre-cast cement concrete block masonry, Type C1 1:3:6 (20 mm graded stone aggregate) with solid blocks, exc. 10 cm in width and setting in mortar 1:4, complete etc complete all as specified and as directed
M&L for rendering 10 mm thick in CM (1:4) on fair faces of brick work or concrete surface finished even and smooth without using extra cement etc complete all as specified and as directed
M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
M&L for PCC 1:2:4 type B-2 using 40 mm graded stone aggregate as in surface channels and drains complete all as specified and directed.
M&L for cement concrete 1:2:4 type, B0 using 12.5mm graded stone aggregates as in copings, fixing of post/ Chajja kerbs, roof padding / staging of water tank etc including necessary fromwork, weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed
M&L Extra for forming fair finished drain or channel 15/20/30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc complete all as specified and directed.
M&L for Precast cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in landings, cover slab (for manholes etc) and similar work including necessary form work and set in CM 1:6 complete all as specified and directed.
Mild Steel TMT bar 6 to 8mm dia cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete.
Taking down carefully aluminium/ copper wiring / power point wiring (light, fan, socket or power) complete including fittings such as switches ceiling roses, regulators, sockets light fittings, fans etc and making good the disturbed surface of walls, ceiling etc incl painting with same colour of the back ground complete all as specified and as directed by Engineer-in-Charge.
Point wiring complete with 1.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl non-metalic rigid PVC conduit medium grade concealed ISI marked incl accessories incl GI/ MS branded sunken boxes of suitable module concealed on walls including modular frame and cover of suitable module fixed with cadmium/heylam plat, iron screws , housing modular type switches, switch socket outlets, fan regulators etc., incl provision of 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed for the following :- One light point controlled by one switch
All as per item No. 111 above but for One fan / exhaust point controlled by one switch / regulator
All as per item No. 111 above but for One 3 pin socket out let 5 Amps on independent board
All as per item No. 111 above but for One bell / buzzer point controlled by bell push
All as per item No. 116 for above but One 3 pin socket out let 5 A on independent board Note for Item No 111 to 114:- (i) The earth wire for the points in the same circuit can be looped from point to point (ii) Earth wire shall be taken inside the conduit (iii) Cost of terminal box is deemed to be included in the item rate quoted for point wiring (iv) Cost of a circuit of any length of cable from DB to any switch/ socket board to be included in point wiring.
Point wiring complete with 2.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl non-metalic rigid PVC conduit medium grade concealed ISI marked incl accessories concealed wiring incl GI/ MS branded sunken boxes of suitable module concealed on walls including modular frame and cover of suitable module fixed with cadmium / heylam plat, iron screws, housing modular type switches, switch socket outlets, fan regulators etc., incl provision of 2.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed. Note for Item No 111 to 115 :- (i) The earth wire for the points in the same circuit can be looped from point to point (ii) Earth wire shall be taken inside the conduit (iii) Cost of terminal box is deemed to be included in the item rate quoted for point wiring (iv) Cost of a circuit of any length of cable from DB to any switch/ socket board to be included in point wiring. (v) Cost of cutting chases for conduits and making good to walls, in case of recessed or concealed conduit wiring will be paid separately in other items.
S&F LED batten suitable for indoor applications 18/20 Watts, 4 feet with extruded aluminium housing & integrated LED channel rectangular white arcylic cover complete with all accessories all as specified and directed. Make: Bajaj, Cat No.BCLAB 18 WH LED P or equivalent Makes & model.
S&F LED batten suitable for indoor applications 10 Watts, 2 feet with polycarbonate housing & integrated LED channel rectangular white arcylic cover complete with all accessories all as specified and directed. Make: Bajaj, Cat No.BCLSB 10 WH or equivalent Makes & model.
Supply in repair and Fix Modular switch 1 way 6A,1 module
Supply in repair and fix Modular switch 1 way 16A, 1 module
Supply in repair and fix Modular switch 2 way 6A,1 module
Supply in repair and Fix Modular Bell push 6A 1 module
Supply in repair and fix modular Socket, 6A - 2/3 pin combined 2 module
Supply in repair and fix modular Socket 6A/16A - 2/3 pin combined 2 module,
Supply in repair and fix modular type Fan step regulator, 120W - 2 module
S&F in repair of Angle holder PVC / polycarbonate type all as specified and as directed
S&F in repair MCB SPN 240 volts 32 Amps complete all as specified and as directed
S&F in repair MCB single pole 240 volts 6 to 32 Amps complete all as specified and as directed
S&F in repair MCB single pole 240 volts 40 Amps complete all as specified and as directed
S&F in repair MCCB 4 pole 415 volts 100 Amps 16 KA, fixed type complete all as specified and as directed
S&F in repair MCB DB SPN 8 way double door type 240 volts with 200 Amps rated busbar as specified and as directed.
S&F in repair Vertical DB (Optium F1 + 12) suitable for MCCB upto 125 Amps and 12 no of outgoing MCB as I/C, double door type 415 volts, IP :54 protection, door earthing, isolated neutral bar, mechanical impact strength IK 09 with insulated bus bar assembly
S&F in repair ceiling rose, surface bakelite type 65 x 50 mm, 2 to 3 terminals all as specified and as directed
S&F in repair Ding Dong bell AC 230 volts single pole.
M&L in repair for provision of new sub main wiring 1100 volts grade multistranded FRLS copper conductors, two runs of single core 4 Sqmm along with 4 Sqm PVC insulated single core multistranded copper conductor cable as earth continuity conductor run along with PVC conduit conceled type all as specified and as directed.
M&L in repair for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to galvanized earth lead wire 4 mm dia as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I 2010 and as specified or indicated and testing on completion incl earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, pre cost slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways incl funnel with watering pipe wire mesh and lugs, incl test point complete all as specified and as directed.incl dismantling and taking down of old earthing.
Supply in repair and fixing in repair 30 W LED bldg security light fitting with pressure die cast housing along with prismatic polycarbonate difuser with IP 66 protection including taking out old fittings.
S&F in repair of Bracket made out of GI tubing medium grade 25 mm bore , approx length 1.5 m long including MS clamps made out of MS flat iron 25 x 6 mm , nuts, bolts, washers etc and including before fixing applying two coats of aluminum paint over a coat of red oxide primer including removing the old existing GI bracket from bldg complete all as specified and directed.
S&F Exhaust fans AC single phase 230/ 240 V of size 225 mm sweep with louvers fixed outside with all accessories and fixing the exhaust fan from ceiling rose with 3 core flexible copper wire 24/0.20 sqmm including core cutting for exhaust fan and making good to walls etc all as directed.
S&F in repair LED Bulb suitable for indoor application of 9 watt, to fit in Angle Holder or Decorative wall light fixture all as directed.
S&F ceiling fans complete with complete accessories, 230V, SP 1200 mm Sweep with BEE 3 Star rating complete with all accessories and fixing the fan from ceiling rose with 3 core flexible copper wire 24/0.20 sqmm, etc all as specified and as directed
M&L for excavation in trenches in hard/dense soil not exc 1.5 mtr wide and not exc 1.5 mtr in depth for laying of water pipe line complete all as specified and as directed.
M&L for returning, filling in trenches incl spreading leveling watering and well ramming in layers with hard/dense soil not exc 25 cm thick in each layer complete as specified and as directed.
M&L for removing excavated surplus soil to a distance exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point all as directed.
Supply, laying and testing new in trenches / walls / ceiling / floor GI pipe 40mm dia medium grade including accessories such as bends, Elbow, Tee, short length, Socket, Union, Nipples incl dismantling and taking out old u/s etc complete all as specified and as directed.
Supply, laying and testing in trenches / walls / ceiling / floor GI pipe 20mm dia medium grade including accessories such as bends, Elbow, Tee, short length, Socket, Union, Nipples etc incl dismantling and taking out old u/s etc complete all as specified and as directed.
M&L in repair for Gun metal, globe or gate valves,with iron wheel head screwed both ends for iron pipe and fixed after taking out old /rusted off one of the 40 mm dia
M&L in repair for Gun metal,globe or gate valves,with iron wheel head screwed both ends for iron pipe and fixed after taking out old /rusted off one of the 20 mm dia
S&F in repair float valves high pressure with polythene float and flynut complete screwed for iron pipe of size 25 mm dia.
M&L for sand cushioning with M sand under and above the cable complete all as specified and as directed. Note: - Punned thickness will be measured for payment.
Supply and lay sub class 'B' old size bricks, desigbation 75 laid in trenches for protection of cables all as directed.
Supply and laying in repairs galvanised iron steel tube, light grade, with all fittings fixed complete on walls, poles, laid under floors or in trenches as cable protection works (including necessary clamps, bolts, nuts, etc.,) as specified for 40 mm bore pipe incl dismantling and taking out old u/s etc complete all as specified and as directed.
S&L XLPE insulated, screened, PVC bedded, galvanised steen strip or wire armouned power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 50 Sqmm, 3.5 core laid in trenches/wall incl dismantling and taking out old u/s etc complete all as specified and as directed.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.25 MB
8288Tender.pdf
Tender Documents • 1.18 MB
BOQ_840233.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .