| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.2 CrAccepted-AOC | ₹3.2 Cr | L1 | Accepted-AOC First Lowest |
| 2 | L2₹3.3 Cr+₹6.3 L (1.93%)Rejected-AOC 182 R 9 SN HIGH ROAD TIRUNELVELI JUNCTION TIRUNELVELI 627 001 | TIRUNELVELI | TIRUNELVELI | TAMIL NADU | 627001 | ₹3.3 Cr+₹6.3 L (1.93%) | L2 | Rejected-AOC Second Lowest |
| 3 | L3₹3.4 Cr+₹12.6 L (3.88%)Rejected-AOC | ₹3.4 Cr+₹12.6 L (3.88%) | L3 | Rejected-AOC Third Lowest |
| Sl No | Description | Qty | Unit | Ryan Engineering L1 | George Engineering Enterprises L2 | SURYAVEL ASSOCIATES L3 |
|---|---|---|---|---|---|---|
| 1.00Dismantling, clearing away and carefully stacking materials useful for re-use for any thickness of walls | ||||||
| 1.01 | Dismantling Pressed tiles & weathering course | 192.68 | m2 | 49.73 ₹9,581.98 Lowest | 50.69 ₹9,766.95 | 51.66 ₹9,953.85 |
| 1.02 | Brick / stone masonry in Cement mortar walls under 3m high | 20 | m3 | 306.22 ₹6,124.4 Lowest | 312.17 ₹6,243.4 | 318.11 ₹6,362.2 |
| 1.03 | Dismantling RCC by manual/by using depolying machineries | 3.35 | m3 | 4,659.86 ₹15,610.53 Lowest | 4,750.35 ₹15,913.67 | 4,840.83 ₹16,216.78 |
| 1.04 | AC sheet roofing without roof timbers | 22.61 | m2 | 19.1 ₹431.85 Lowest | 19.47 ₹440.22 | 19.84 ₹448.58 |
| 2.00 | Earth work excavation for foundation by Mechanical means for Isolated & Combined Footing etc in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 100 mts and clearing and levelling including dressing of sites and raming of bottoms at the site, etc., complete complying with standard specification and as directed by the departmental officers.
a. for Footing Depth 2.40m to 3.3m | 280 | m3 | 375.27 ₹1,05,075.6 Lowest | 382.56 ₹1,07,116.8 | 389.84 ₹1,09,155.2 |
| 3.00 | Earth work Open excavation by Mechanical Means for Open Earthwork in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 100 mts and clearing and levelling including dressing of sides and raming of bottoms etc., complete complying with standard specification and as directed by the departmental officers.
A). Upto 2.40m Depth. | 131 | m3 | 204.41 ₹26,777.71 Lowest | 208.36 ₹27,295.16 | 212.35 ₹27,817.85 |
| 4.00 | Refilling with excavated earth other than sand with an initial head load of 100 mts. and depositing the earth as shown by the departmental officers in layers of not more than 15cm thick well rammed with surface vibrator, watered and consolidated etc., complete complying with standard specification and as directed by the departmental officers. | 84 | m3 | 160.7 ₹13,498.8 Lowest | 163.82 ₹13,760.88 | 166.94 ₹14,022.96 |
| 5.00 | Supplying and filling in foundation, basement, etc with stone dust in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.. | 38 | m3 | 304.29 ₹11,563.02 Lowest | 310.2 ₹11,787.6 | 316.11 ₹12,012.18 |
| 6.00 | Supplying and filling in foundation, basement, etc with filling crushed stone sand in layers of not more than 15 cm thick well watered, Without consolidation etc. complete complying with standard specification and as directed by the departmental officers. | 5 | m3 | 1,518.02 ₹7,590.1 Lowest | 1,547.5 ₹7,737.5 | 1,576.98 ₹7,884.9 |
Tender Value
₹3.2 Cr
EMD Value
₹1.7 L
Closing Date
3 Jul 2025, 3:00 pmClosed
Superintending Engineer
Office of the Superintending Engineer, PWD., Buildings Construction and Maintenance Circle, Tirunelveli
Construction of Integrated Registration office Building at Melapalayam in Tirunelveli District.
2025_PWD_571295_1
6 (1) SE/2025-26 dated 17.06.2025
Open Tender
Civil Works - Buildings
Lump-sum
300 days
melapalayam
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹1.7 L
30 Sept 2025
19 Jun 2025
4 Jul 2025
19 Jun 2025
3 Jul 2025
19 Jun 2025
Amount
Dismantling, clearing away and carefully stacking materials useful for re-use for any thickness of walls
Dismantling Pressed tiles & weathering course
Brick / stone masonry in Cement mortar walls under 3m high
Dismantling RCC by manual/by using depolying machineries
AC sheet roofing without roof timbers
Earth work excavation for foundation by Mechanical means for Isolated & Combined Footing etc in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 100 mts and clearing and levelling including dressing of sites and raming of bottoms at the site, etc., complete complying with standard specification and as directed by the departmental officers. a. for Footing Depth 2.40m to 3.3m
Earth work Open excavation by Mechanical Means for Open Earthwork in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 100 mts and clearing and levelling including dressing of sides and raming of bottoms etc., complete complying with standard specification and as directed by the departmental officers. A). Upto 2.40m Depth.
Refilling with excavated earth other than sand with an initial head load of 100 mts. and depositing the earth as shown by the departmental officers in layers of not more than 15cm thick well rammed with surface vibrator, watered and consolidated etc., complete complying with standard specification and as directed by the departmental officers.
Supplying and filling in foundation, basement, etc with stone dust in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers..
Supplying and filling in foundation, basement, etc with filling crushed stone sand in layers of not more than 15 cm thick well watered, Without consolidation etc. complete complying with standard specification and as directed by the departmental officers.
Supplying and filling in foundation, basement, etc with conveyed earth in layers of not more than 150mm thick layers well watered, rammed with surface vibrator and consolidated including conveyance charges etc. complete complying with standard specification and as directed by the departmental officers.
Cement Concrete 1:5:10 (One Cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and including curing etc. complete complying with standard specification and as directed by the departmental officers -Mixing by mechanical means
Pre-Construction anti-termite treatment plinth area – surface treatment stage-1 :- Completion of earth work for column footings before laying plain cement concrete 25mm dia Hole spaced at 30cm center to center on both direction will be made at the bottom of earth workand the chemical will be poured in the holes and will be sprayed in the four sides of earth work at the rate of 3 litres of chemical solution (Chlorophyrifos emulsion diluted in ration 1:19 (One emulsion and 19 water ) per square metre payment shall be made after completion of 3 stages. stage-II :- After filling the basement before laying flooring concrete with filling Crushed stone sand(M-Sand) 25mm dia holes to adepth of 450mm will be made inside the basement and the chemical will be poured in the holes at the rate of 3 litres of chemical solution (Chlorophyrifos emulsion diluted in ration 1:19 (One emulsion and 19 water ) per square metre payment shall be made after completion of 3 stages.
Peripheral treatment stage-III.On completion of building and leveling the outer area adjacent to the walls column ground ponds of size (900X300 mm will be filled in the ponds at the rate of 3 litre of chemical solution per Rm payment shall be made after completion of 3 stages. Stage-IV.Spraying termite solution around the building (Out side of the building) by making crowbar holes around the building before laying the plinth protection. This holes has to be closed after the treatment
Damp proof course as per IS 3067:1988 with Cement Mortar 1:4 (One Cement and Four crushed stone sand) 12mm thick mixed with best approved quality Integral liquid water proofing compound conforming to Indian Standard specification as specified by the departmental officers at 2% by weight of cement used , finishing and curing etc. complete complying with standard specification -Manual Mixing
Brick work in Cement Mortar 1:5 using best quality Burnt Clay Brick of size 8 3/4" x 4 1/4" x 2 3/4" with class designation of 7.5 conforming to IS 1077-1992 for foundation and basement including Cost of Mortar Plasticizer curing, etc.,complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally.other type of bond shall be done as directed by the Executive Engineer in charge.
In Foundation & Basement
Brick work in Cement Mortar using 1: 6 best quality Burnt Clay Brick of size 8 3/4" x 4 1/4" x 2 3/4" with class designation of 7.5 conforming to IS 1077-1992 for foundation and basement including Cost of Mortar Plasticizer curing, etc.,complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally.other type of bond shall be done as directed by the Executive Engineer in charge.
In Ground Floor
In First Floor
In Second Floor
In Third Floor
In Fourth Floor
Brick partition walls of 10.80cm thickness using best quality Burnt Clay Brick of size 8-3/4" x 4-1/4" x 2-3/4" with class designation of 7.5 conforming to IS 1077-1992 in Cement Mortar 1:3 (One Cement and Three CS Sand) using hoop iron reinforcement if found necessary including Cost of Mortar Plasticizer, curing etc. complete complying with standard specification and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately)
In Ground Floor
In First Floor
In Second Floor
In Third Floor
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, Sill slabs etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid with silver oak joists of size 10cm x 5cm & 7.5cm x 5cm as support runner , vertical stiffener , side support and Top Horizontal stiffener spaced at about 60cm to 90cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid).)
Supplying and erecting centering for plane surfaces such as RCC Floor/Roof Beam, Lintels, Cantilever Beams, Bed Blocks etc. with necessary supports and strutting upto 3.60m height in all floors with all cross bracings using MS Sheets made of 10 gauge thick welded with MS angle of Size 25mm x 25mm x 3mm for boarding laid over Steel adjustable Span of Size 2m x 2m(expandable upto 3.60m) and Silver Oak Joists of Size 10 x 5 cm spaced at 50cm to 60cm c/c and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick) Spaced at not more than 50 to 60cm c/c , etc complete complying with standard specifications. Steel adjustable span and Steel Adjustable telescopic props shall be provided as directed by the departmental Officers. (Payment for centering shall be given after the concrete is laid).
Supplying and erecting centering for plane surfaces such as RCC Floor Slab, Roof Slab, Loft, Landing Slabs, etc with necessary supports and strutting upto 3.60m height in all floors with all cross bracings using MS Sheets made of 10 gauge thick welded with MS angle of Size 25mm x 25mm x 3mm for boarding laid over steel adjustable span of size 2m x 2m (expandable upto 3.60m) and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick) , etc complete complying with standard specifications. Steel adjustable span and Steel Adjustable telescopic props shall be provided as directed by the departmental Officers. (Payment for centering shall be given after the concrete is laid).
Supplying and erecting steel centering including necessary supports For plane surfaces such as rectangular or square RCC columns etc. which require only nominal strutting using mild steel sheets made of 10 gauge thick welded with MS angle size 40mm x 40mm x 5 mm and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick).etc..complete in all floors complying with standard specifcation. Steel Adjustable telescopic props shall be provided as directed by the departmental Officers. (Payment for centering shall be given after the concrete is laid).
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as vertical slab, side slabs of boxing, vertical drops, facia, vertical wall, etc. using mild steel sheets of size 120cm x 60cm and 10 BG stiffened with welded mild steel angles of size 40mm x 40mm x 5 mm for boarding, laid with silver oak joists of size 10cm x 5cm & 7.5cm x 5cm as support runner, Top Horizontal stiffener spaced at about 60cm to 90cm centre to centre or at suitable intervals. MS Channel Section (ISMC 100) shall be provided as a vertical support @1.20m C/C and with Lateral support of Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) & steel pipes of 20mm dia @ required level/spacing etc. complete complying with standard specifcation and as directed by the departmental officers. (Payment for centering shall be given after the concrete is laid)
Providing and laying in position, standardised concrete Mix M-20 Grade by insitu machine mix concrete adopting weighing batch method in accordance with IS 456 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m) 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill
and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials).
In Foundation & Basement
In Ground Floor
In First Floor
In Second Floor
In Third Floor
In Fourth Floor
Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel reinforcement grills of all variety like HYSD/CTD/TMTand all grade like Fe 500, Fe550D, Fe 500 D etc., for all RCC works as per design given including cost of steel reinforcement and G.I. binding wire, wastage etc. complete complying with standard specification and as directed by the departmental officers.(Contractor has to make his own arrangements for the supply of steel reinforcement and binding wire)
In Foundation & Basement
In Ground Floor
In First Floor
In Second Floor
In Third Floor
In Fourth Floor
Plain Cement Concrete 1:2:4 (one cement, two crushed stone sand and four hard broken stone jelly) using 20mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers.-Mixing by mechanical means
Supplying and filling ISS metal of following size in dispersion trench including stacking for pre measurements around the stoneware pipe or in the leach pit or soak pit to the required thickness as directed by the departmental officers etc.,complete.- a) 20mm ISS metal
Supplying and filling ISS metal of following size in dispersion trench including stacking for pre measurements around the stoneware pipe or in the leach pit or soak pit to the required thickness as directed by the departmental officers etc.,complete.- a) 40mm ISS metal
Cement Concrete 1:5:10 (One cement, Five C.S sand and Ten hard broken stone) using 40 mm gauge hard broken jelly for flooring including laying, consolidating, finishing, rendering the top surface rough to receive the floor, curing, etc. complete complying with standard specification. (The rate is inclusive of necessary planking for panelling wherever necessary and as directed by the departmental officers. Mixing by mechanical means
Paving the floor with best quality Double Charged Vitrified Tiles of size 600x600x8mm and variety conforming IS 15622 with water absorbtion less than 0.08% of approved colour and shade laid over cement mortar bed of 20mm thick in cement mortar 1:3 (one cement and three crushed stone sand) with required Cement Slurry and Mortar Plasticizer in all floors and the top pointed with Water Resistant Tile Epoxy Grout etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Flooring with ceramic tiles of size 305mm x 305mm x 6mm and variety conforming to IS 15622 laid over cement mortar bed of 20 mm thick in cement mortar 1:3 (One Cement and Three crushed stone Sand) with required Cement Slurry and Mortar Plasticizer including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m. etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Paving the floor with best approved quality fine polished Granite Stone Slabs of following size and Variety with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three crushed stone sand) with required Cement Slurry and Mortar Plasticizer and laid in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments etc., complete complying with standard speicification and as directed by the departmental officers.(The granite stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work)Using Synthetic Grey, Paradise and Similar Varities of size 1200X600 of 18/20mm thick
Paving the floor with best approved quality fine polished Kota stone slabs of size 600 x 600 and above 20mm thick with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three crushed stone sand) with required Cement Slurry and Mortar Plasticizer fixing the slabs in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments and polishing with floor polisher to a high degree of finish etc., complete complying with standard speicification and as directed by the departmental officers.(The kota stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work)
Paving the floor with Cement based Hydraulically pressed Anti skid tiles (pattern design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three C.S sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Supplying and laying of Interlocking Paver Block Stone 60mm thick Over a base layer of crushed stone sandfilling incl. Cost of materials laying and Labour charges etc complete complying with the standard specification and as directed by the departmental officers.
Dadooing walls with best approved quality, Printed design colour glazed tiles conforming to IS 15622 of size 300 x 450x 8mm in Cement Mortar 1:2 (One Cement and Two crushed stone sand),10 thick with Mortar Plasticizer and pointing the joints with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m. neatly in all floors, curing, etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Dadooing with Granite Slabs (Super Fine Polished with Machine Cut Edges) of sizes 4’x2’ and above 18mm to 20mm thick in Cement Mortar 1:2 (One Cement and Two crushed stone sand),10 thick with Mortar Plasticizer and pointing the joints with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m. neatly in all floors, curing, etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Plastering with Cement Mortar 1:5 (One cement and Five Plastering sand), 12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curing etc. complete complying with standard specification and as directed by the departmental officers.
Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Plastering Sand) 10mm thick including mortar plasticizer at 200ml per 50Kg of cement used , hacking the surfaces and curing, etc., in all floors complying with standard specification and as directed by the departmental officers
Plastering with Cement Mortar 1:3 (One Cement and Three Plastering Sand) 12mm thick mixed with water proofing compound conforming to BIS at 2% by weight of cement used including mortar plasticizer at 200ml per 50Kg of cement used, finsihing, curing, etc., complete in all floors complying with standard specification and as directed by the departmental officers.
Providing Polymer Coating (Water Proof Coating) for sunken Portion of toilet with following specification and the surface shall be cleaned to remove all dust, foreign, matters lose materials or any other deposits of contamination by rubbing with wire brush.Slurry: Dry blend and polymer liquid blend shall be mixed into the desired ratio as per recommendation of the supplier. The mix shall be stirred throughly until no bubbles remain in the mix. Any lumps found in mix shall be removed. Apply first coat of polymer modified cementitious slurry by brush on wet cleaned surface. After drying, second coat shall be applied on the first coat as directed by the departmental officers etc. The rate inclusive of cost of materials and labour, etc., complete.
Supply & Fixing PVC Beading etc., complete and as directed by the departmental officers.
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase near wet riser using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick will be provided with tubular supports made of 304L Grade Stainless Steel pipe of25mm dia of 1.60mm thick welded to the railing. The supports will be grouted into the wall and provided with 93.00mm thick Stainless Steel circular base plate of 304 Grade. The rate shall included for grouting into concrete with necessary supporting arrangements the hand rail in floor polishing buffing, bonding, cutting, grinding, conveyance, welding charges, electrical charges, etc. complete
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900 mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete
Providing Double Nosing the Granite slab to half edge to round shape and finishing the surface neatly etc.,in all floors complying with standard specification and as directed by the departmental officers
Providing Grooving the granite slab flooring in Steps and wall top etc., in all floors complying with standard specification and as directed by the departmental officers
Brick Jelly Lime Concrete 1:2:5 (one Lime,Two Crushed Stone Sand and Five brick jelly) using 20mm brick jelly in Lime Mortar 1:2 etc., complete complying with standard specification and as directed by the departmental officers.
In First Floor
In Second Floor
In Third Floor
Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no crushed stone sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers.
Finishing the top of roof with one course of machine pressed tiles of size 230mm x 230m x 16 to18 mm of approved quality set in Cement Mortar 1:3 (One Cement and Three Crushed stone Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers
Supplying and fixing in position best approved BIS quality of PVC rain water down fall pipes having a working pressure of 4 Kg./sq.cm of following dia. including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc. and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc. complete. The rate shall be inclusive of cost of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of clamps. Special type of "U" clamp at the centre of the pipe line shall be fixed in addition to those for more than 3.0 metre pipe length etc., complete complying with standard specification.
110 mm dia pipe for four floors
Stainless Steel (Salem Stainless Steel) Door Frame (Box Section using Stainless Steel Plate of 1 mm thick) of size 100mm x 60mm with a rebate of 30 / 35mm x 15mm on one side of the frame including supplying and fixing dovetail splayed end stainless steel hold fast etc
Supplying and fixing solid core flush shutter of 35 mm thick with Teak ply on both side of following type with thickness with necessary T.W. internal lipping alround conforming to IS 2202-1(1999) including cost of wind appliances and furniture fittings such as 3 Nos of SS 304 Grade Butt Hinges of Size (125mm x 30mm) , 2 Nos 300x12mm aluminium tower bolt 1 No. 200x12mm aluminium tower bolts 1no. 250x16mm aluminium aldrops, 2 nos. 200mm ‘D’ type aluminium door handle and door stopper with bush etc., complete complying with standard specification and as directed by the departmental officers
Single leaf 1.0 x 2.1m
Supplying and fixing solid core flush shutter of 35 mm thick with Teak ply on both side of following type with thickness with necessary T.W. internal lipping alround conforming to IS 2202-1(1999) including cost of wind appliances and furniture fittings such as 6 Nos of SS 304 Grade Butt Hinges of Size (125mm x 30mm) , 3 Nos 300x12mm aluminium tower bolt 1 No. 200x12mm aluminium tower bolts 1no. 250x16mm aluminium aldrops, 3 nos. 200mm ‘D’ type aluminium door handle and 2 nos of aluminium door stopper with rubber bush etc., complete complying with standard specification and as directed by the departmental officers
Double leaves 1.2 x 2.1m
Manufacturing supplying and fixing of Fully Panelled steel door with the following specification MS angles of size 40x40x6mm are used for the outer frames and M.S. angles of size 35x35x5mm for the shutter frames, stiffeners with 32 x 6mm M.S flat is provided at required intervals in the shutter frame. 18-gauge C.R. sheet laid as panel in the shutter and welded intact. M.S. flat 18x5mm is welded over the 32 x 6mm M.S. flat sandwitching the C.R. sheet in between additional stiffeners with 18x5mm M.S. flat is provided diagonally at the rear side of the shutter. 3nos. of Steel Parliament Hinges of Size 125mm x 150mm in case of single leaf and 6nos. of Steel Parliament Hinges of Size 125mm x 150mm in double leaves shutter to be provided. 6nos. of holdfasts 200 mm in length made of angle section spliced at the ends are welded to the outer frames of the door.
Tower bolts 3 nos, one at the top, one at lock rail(Inner) and the other at the bottom are provided 1no. Aldrop is provided at lock rail section in the door 2 Nos of 200mm handle are to be provided. One rotaing locking arrangements for the inner side of the door and additional provision for locking arrangements for lock is provided on the rear side of the door at an appropriate place. Incase of double leaf door M.S.Flat 32 x 3mm at 1.1Kg/m is provided on the one shutter to conceal the gap between the two shutters.at an appropriate place in the door. A tie bar is provided at the bottom of the frame to prevent twisting of frame during transportation and fixing. All members are given a coat of red oxide primer as directed by the departmental officers. The rate includes cost of all materials, labour charges, transportation to site of work, loading, un loading and all other incidental charges etc., complete complying with standard specification and as directed by the departmental officers. - Single leaf of size 1.00m x 2.10m. Single Leaf 1.00x2.10m (Fullysheeted)
Single leaf
Manufacturing, supplying and fixing of 1/3 panelled and 2/3 grilled steel doors with the following specification M.S angles of a size 40x40x6mm are used for the outer frames and M.S. angles of size 35x35x5mm for the shutter frames stiffeners with 32x6mm M.S. flat is provided at required intervals in the shutter frames 18 gauge C.R. sheet is laid as panel in the shutter and welded intact for 1/3 bottom portion of the shutter. M.S. flat 18x5mm is welded over the 32x6mm M.S. flat sandwitching the CR sheet in between. Additional stiffener with 18x5mm M.S. flat is provided diagonally at the rear side of the shutter. The balance 2/3 portion at top is provided with grill at an average weight of 20kg/sq.m and 3 Nos Steel Parliament Hinges of Size 125mm x 150mm incase single leaves shutter to be provided, 6 Nos Steel Parliament Hinges of Size 125mm x 150mm for double leaves shutter to be provided, 6nos of holdfasts 200mm in length made of angle section spliced at the ends are welded to the outer frame of the door. Tower bolts 3 nos, one at the top, one at lock rail(Inner) and the other at the bottom are provided. one aldrop is provided at on appropriate place in the door. 2Nos of handle are to be provided.
A Tie bar is provided at the bottom of the outer frame to prevent twisting of frame during transportation or fixing. All members are given one coat of red oxide primer as directed by the departmental officers. The rate includes cost of all meterials, labour charges, taxes, transportation to site of work, loading, unloading and all other incidental charges etc., complete complying with standard specification and as directed by the departmental officers. - Single leaf of size 0.90m x 2.10m.
Single Leaf ( 1/3 sheeted & 2/3 grilled)
Supplying and fixing PVC sliding door with Solid PVC door shutters using 19 Gauge 19mm MS square tubes for styles and outer frames, 15mm MS square tubes for top, lock and bottom rails. The steel tubes shall be covered with 5mm thick solid PVC sheets. Shutter using 5mm thick solid PVC sheets for panelling shall rigidly fixed in position including necessary furniture and fittings. The over all size of styles shall be 50mm x 30mm. The over all size of top rail, Lock rail and bottom rail shall be 75mm x 30mm. The over all size of frames shall be 50mm x 45mm, with suitable rabate for housing the shutter including sliding arrangements.
Supplying & fixing Solid PVC door shutters using 19 Gauge 19mm MS square tubes for styles and outer frames. 15mm MS square tubes for top, lock and bottom rails. The steel tubes shall be covered with 5mm thick solid PVC sheets. Shutter using 5mm thick solid PVC sheets for panelling shall rigidly fixed in position including necessary furniture and fittings. The over all size of styles shall be 50mm x 30mm. The over all size of top rail, Lock rail and bottom rail shall be 75mm x 30mm. The over all size of frames shall be 50mm x 45mm, with suitable rabate for housing the shutter.
UPVC Window Specification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and
it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work
UPVC Ventilator Specification:Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work
supplying and fixing Ms grills for doors, windows and ventilators of approved design and as directed by the departmental officers including cost of ms grills labour charges and cost of one of red oxide primer coat etc., complete complying with std. specification.
Painting two coats of newly plastered wall surface with ready mixed Plastic Interior emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, etc., complete complying with standard specification.
Painting two coats of newly plastered wall surface with ready mixed plastic Exterior emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, etc., complete complying with standard specification.
Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
Painting new wood work with two finishing coats of synthetic enamel ready mixed paint of approved quality and colour over one coat priming coat in all floors including the cost of primer etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
Supplying, laying and jointing CPVC (chlorinated Poly vinyl chloride) pipe( Higher pressure rating with higher pipe thickness) Standard Dimension Ratio- 11)of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing CPVC specials using cement SOLVENT (but excluding cost of such specials) and fixing into wall with teak wood plugs, CPVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications. The CPVC pipes shall be got approved by Executive Engineer before use on works. Above Ground level-Internal Water Supply
25 mm dia CPVC pipe
20 mm dia CPVC pipe
Supplying, laying and jointing CPVC (chlorinated Poly vinyl chloride) pipe( Higher pressure rating with higher pipe thickness) Standard Dimension Ratio- 11)of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing CPVC specials using cement SOLVENT (but excluding cost of such specials) and fixing into wall with teak wood plugs, CPVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications. The CPVC pipes shall be got approved by Executive Engineer before use on works.
Above Ground Level - External Water Supply
40 mm dia CPVC pipe
32 mm dia CPVC pipe
25 mm dia CPVC pipe
Supplying, laying and jointing CPVC pipes of Standard Dimension Ratio-11 (Pressure class 1) conforming to IS:15778 - 2007 of approved quality and best variety of the following dia including cutting and fixing CPVC specials using CPVC adhesives (Solvent Cement) (but excluding cost of such specials) and fixing into wall with teak wood plugs,CPVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications and as directed by the departmental officers. (The CPVC pipes shall be got approved by Executive Engineer before use on works). - External water supply above ground level / Below ground level.
Below Ground Level - External Water Supply
40 mm dia CPVC pipe
Supplying CPVC Specials of SDR 11 conforming to IS 17546-2021 in water supply ar rangements (both in internal and external water supply arrangements
32 mm dia CPVC Union
25 mm dia CPVC Union
40 mm dia CPVC Elbow
32 mm dia CPVC Elbow
25 mm dia CPVC Elbow
20 mm dia CPVC Elbow
40 mm dia CPVC Coupling
32 mm dia CPVC Coupling
25 mm dia CPVC Coupling
20 mm dia CPVC Coupling
32 mm dia CPVC Tee
25 mm dia CPVC Tee
20 mm dia CPVC Tee
32 x 25 mm dia Reducer Tee
25 x 20 mm dia Reducer Tee
20 x15 mm dia Reducer Tee
32 x 25 mm dia Reducer Elbow
25 x 20 mm dia Reducer Elbow
20 x15 mm dia Reducer Elbow
32 x 25 mm dia Reducer
25 x 20 mm dia Reducer
20 x15 mm dia Reducer
32 mm dia CPVC Bend
25 mm dia CPVC Bend
Supplying and fixing in position first quality and approved variety of Gun metal Gate Valve with BIS make of the following dia including cost of shellac, thread balls, etc., complete complying with standard specifications (for both internal and external water supply arrangements). The valves to be used on work shall be got approved by the Executive Engineer before use on work.
40mm dia
32mm dia
Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. (The PVC pipes should be got approved by the Executive Engineer before use on works).
160mm dia PVC soil pipe
110mm dia PVC soil pipe
75mm dia PVC soil pipe
Supplying and fixing in position of the following P.V.C. specials of best approved quality confirming to B .I.S. and providing leak proof joints with P.V.C. adhesive etc, including fixing to walls with necessary teak wood plugs screws etc. and giving connections to the P.V.C .pipe dismantling the brick masonry RCC floor or roof slab and making good the disturbed portion to original conditions etc. complete complying with standard specifications. (The P.V.C. specials should be got approved from the Executive Engineer before use on works).
110 mm dia PVC Elbow
110 mm dia PVC Elbow with door
75 mm dia PVC Elbow with door
110 mm dia PVC Y-Single door
75 mm dia PVC Y-Single door
110 mm dia PVC bend
75 mm dia PVC bend
Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm white glazed earthern ware of approved quality and brand with "P" or "S" trap conforming to BIS with Crushed Stone(M-Sand) cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two Crushed Stone(M-Sand) and Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to PVC pipes (including the cost of 110mm dia PVC pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers. (The water closet should be got approved by the Executive Engineer before use on works).
Supplying and fixing in position White Glazed EUROPEAN WATER CLOSET of best quality and approved make with 100mm P or S trap connecting with PVC pipe of 110mm dia, double flapped rigid PVC. seat and seat cover with chromium plate brass hinges, including supplying and fixing 10 litres capacity PVC flushing tank with a pair of CI Brackets etc., complete with all fittings such as 15mm brass valve with polythene float with brass handle union, coupling connected by means of 40mm
white PVC flush and using indian adopter joint including all internal fittings such as 15mm brass connections, 15mm gm wheel valve, 15mm brass nipple (2 nos), 15mm nylon connections TW plugs, screws and also giving necessary connection to the PVC pipe including cost of 600mm length of 110mm dia PVC pipe and painting CI brackets with 2 coats of approved paint over one coat of red oxide primer , dismantling the masonry and re doing the dismantled masonry to original condition etc. complete complying with standard specifications. The European Water Closet and flushing tank with all accessories should be got approved by the Executive Engineer before use on work. a)White glazed EWC with 10 litres capacity, PVC flushing tank fixed on wall
Supplying and fixing in position best quality and approved make Indian made white glazed earthernware wash hand basin of size 550 x 400mm with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia "B" class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers,
white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works). a) White glazed Wash hand basin of size 550x400mm without Pedestal
Supply and fixing in position of best Indian make white glazed earthernware lipped mouth flat back urinal of best quality and approved make of size 430mm x 260mm x 350mm with GI pipe, 32mm dia bell mouth PVC connection and waste pipe, 15mm dia GI pipe of required length, 15mm dia GM wheel valve, 15mm dia brass nipple 2 Nos., and fixing the urinals in position with necessary TW plugs, clamps, screws, etc., including dismantling masnory and re-doing the same to the original condition, etc., including painting the pipe with two coats of best quality approved synthetic enamel paint over one coat of red oxide primer and checked without any leakage etc. complete complying with standard specifications and as directed by the departmental officers. (The urinal should be got approved by the Executive Engineer before use on works.)
Supplying and fixing in position Urinal partition with White Marble slab (Adanga) 18 mm to 20 mm thick of 4'0'' x 2'0''size and above of best quality including dismantling masonry, if necessary and re-doing the same to original condition, etc., complete complying with standard specification. (The Marble slab should be got approved by the Executive Engineer before use on works).
Supplying and fixing of SS Sink of size 1200 x 550 x 180mm of best approved quality etc., complete complying with standard specifications and as directed by the departmental officers
Supplying and fixing position PVC Nahani Trap / Floor Trap of the following sizes with best PVC gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of crushed stone sandand five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three sand) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to the CI / PVC pipes, etc., complete complying with standard specification. (The Nahani Trap should be got approved by the Executive Engineer before use on works)
PVC Nahani Trap of size 100 x 75mm with PVC gratings
Supplying and fixing in position 15mm dia. brass C. P. screw down tap ( Heavy duty ) of best approved make and quality including cutting, threading wherever necessary and fixing in position etc., complete complying with standard specification ( Screw down tap to be used on works should be got approved from the Executive Engineer before use).
15 mm dia CP screw down tap
Supplying and fixing best approved best quality brass CP soap tray of size 150 x 150mm including cost of teak wood plugs, brass screws, etc., complete complying with standard specifications. (The soap tray should be got approved by Executive Engineer before use on works).
Supplying and fixing in position Indian make bevelled edge mirror of approved quality and brand PVC / Fibre Glass framed 600 x 450 x 5.5mm thick mirror, shelf type with hard board backing of approved colour fixed with brass screws, rawl plug, etc., complete complying with standard specification. (The mirror should be got approved by the Executive Engineer before use on woks)
Supplying and fixing approved best quality brass CP towel rail 600mm long and 20mm dia with brackets of same materials including cost of teak wood plugs and CP screws, etc., complete complying with standard specifications. (The tower rail should be got approved by Executive Engineer before use on works).
Supplying and fixing in position C.I. Manhole covers with CI frames (Heavy duty) of size 60 cm x 60 cm of best approved quality as per standard specification etc. complete.
Manufacturing, supplying and fixing Precast Reinforced Cement Concrete slabs of following thickness in RCC 1:2:4 (one cement, two crushed stone sand and four aggregates), using 20 mm HBGS jelly excluding cost of reinforcement steel in position but including cost of moulding charges, casting of slab, finishing, curing and fixing in position in all floors etc., complete complying with standard specification and as directed by the departmental officers.
50 mm thick slab
Manufacturing, supplying and fixing in position plain cement concrete precast pavement slab of size 450mm x 450mm of 50mm thick in Cement Concrete 1:2:4 (One cement, Two crushed stone sand and Four jelly) using 20mm HBG stone jelly including cost of moulding charges, casting of slab, finishing, curing, fixing and pointing the slab with CM 1:3 (One Cement and Three C.S Sand) to full depth of slab etc., complete complying with standard specification and as directed by the departmental officers
Drilling of 6" (150mm) dia vertical borewell to the required depth as directed by the departmental officers in all soils such as hard rock strata including all incidental charges for drilling machineries transportation for rig machineries and supporting vehicle to work spot,charges to fuel required for operation, labour charges for driling bore well to the required depth according to water table as directed by the departmental officers inculding clearing the site after completion of work complying with standard specification.
Upto 150m below Ground Level
From 151m upto 180m
From 181m upto 210m
Supplying and inserting PVC casing pipe 160mm dia for borewell to with stand the vertical pressure of 6Kg/cm2 without slot including with coupling wherever necessary including cost of cutting and threading and transporting the pipe to work and as directed by the departmental officers etc., including labour charges etc.,complete
Supplying and fixing of suitable PVC endcap (6kg/cm2)for 6"dia borewell of best quality with ISI mark (the PVC endcap should be not approved by the departmental officers before execution)
Supplying and Fixing of 32 mm dia HDPE pipe of approved quality and best variety conforming to ISI mark of the following dia size for suction pipe for compressor motor as directed by the departmental officers.
Supplying and fixing Nylon Rope for Bore-well etc., complete Complying with Standard Specification and as directed by the departmental officers.
Supply of 4.00 sqmm three core flat copper cable with wire bounded punched copper conductor insulated and sheeted with PVC.for submersible pump motor with voltage grade upto 1100V confirming to and marked with IS (694-1990) complying with standard specification etc.complete.
Supplying single phase 3 HP submergible pump of approved make conforming to IS 8034 and all cost of materials. The quality and standard of the product should be got approved by the departmental officers before use on works. Necessary Warranty card should be got approved before erection of submergible pump with all accessories.
Supply three phase capacitor type 2.0 HP monoblock motor with suitable for 220V 50HZ, AC electrical supply with 1420/1440 RPM motor of best quality and make with ISI mark on a suitable pedestal with foundation bolt and nut with panel board with accessories such as 1No. 15Amps DPIC switch, 1 No. voltmetre 0 to 500V with control switch, 3Nos. Indicator lamps with 5 amps control switch,1no. 15Amps fuse carrier and giving electrical wiring connections. The rate includes supplying and fixing of 1no. of foot valve pump set including wiring from panel board to motor, etc., complete (The pump should be tested for a minimum of three days at contractor’s own cost)
Supplying and fixing in position of P.V.C water storage tank of best approved quality and brand of super thick with the capacity of 1000 Litres with accessories including giving necessory connections etc., complete as directed by the departmental officers. ( The P.V.C. water storage tank should be got approved by the Executiove Engineer before use on works.)
Supplying, fabricating, erecting and fixing Hilux (or) Equivalent Board False Ceiling upto a ceiling height of 4.5m from floor level - Using Hilux Board Plain Sheets (10mm thick)
Supplying and erecting in position of 250 liters capacity Industrial Model Reverse Osmosis Water-cum-Purifier to deliver Potable Water with World Health Organisation (WHO) Standards with following accessories. (a) MS Skid - 1 No. (b) Media 11054 No. Vessel with 20 nb Multiport Valve (with Media Pubble and Fine Sand and Activated Carbon Filling) set (c) Feed Pump 0.50 HP – 1 No. (d) Vertical Pump 2-9, 2.00 HP / Single Phase – 1 No. (e) Membrane 40 x 40 filmtech (or) equilaents / Osmonic (USA) - 1 No. and Membrane Pressure Vessel 40 x 40 -1 No. & Pressure Gauge - 2 Nos. (f) Flow Meter - 1 No. 20” Filter with Housing - 1 No., Low Pressure Switch - 1 No., Level Switch - 1 No. & Necessary CPVC Pipes and Fittings. The system shall be provide with Two Panel Control System with necessary Stainless Valves and Fittings and Float Control etc. The rate should be inclusive of all civil works, wherever necessary to install the System in position and intact.
Supplying and fixing fine polished cuddapah slab of following thickness for cup-board arrangements including laying to correct alignment with necessary cement mortar and black powder etc, complete complying with standard specification and as direct by the departmental officers - 38 / 40mm thick
Providing Cup-board Shutter using termite / water proof plywood of 19mm thick over which laminated sheet of 0.8mm thick fixed inside the shutter and 1mm thick fixed in the outside of the shutter using fevicol along with necessary furniture fittings, such as, hydralic hinges, tower bolt, handles, multi purpose locks etc., as directed by the Departmental Officers. The design pattern, water proof plywood, laminate sheet and other materials should be got approved from the Executive Engineer befoe use on work.
Supplying and fixing Polycarbonate sheet 6mm thick of approved quality by drilling holes (and not by punching) with necessary ‘J’ / ‘U’ bolts and nuts etc., complete complying with standard specification and as directed by the departmetal officers
Supplying and fixing 50mm dia GI pipe for Purlins including labour charges for cutting, welding and fixing with polycarbonate Sheet roofing etc., as directed by the departmental officers
George Engineering Enterprises (BID ID -1389371)
SURYAVEL ASSOCIATES (BID ID -1390020)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .