Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.7 LAccepted-AOC GAUSHALA MARKET TEHSIL NARNAUL NARNAUL 123001 | NARNAUL | NARNAUL | HARYANA | 123001 | L1 | Accepted-AOC LOA issued | |
| 2 | L2₹36.7 L+₹3.0 L (8.89%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹38.8 L+₹5.1 L (15.2%)Rejected-Finance H NO 787 22 JHANG COLONY ROHTAK 124001 | ROHTAK | HARYANA | 124001 | L3 | Rejected-Finance L3 | |
| 4 | L4₹41.2 L+₹7.5 L (22.3%)Rejected-Finance KHASRA NO 183 10 SHYAM VIHAR HISAR HISAR HARYANA 125001 | HISAR | HARYANA | 125001 | L4 | Rejected-Finance L4 | |
| 5 | L5₹43.8 L+₹10.1 L (30.1%)Rejected-Finance | L5 | Rejected-Finance L5 |
Tender Value
₹35.7 L
EMD Value
₹71,320
Closing Date
20 Jan 2025, 5:00 pmClosed
AMIT GOYAL
ED - Karnal
Replacement of old 250 KVA DG set with 400KVA DG set in DC Block at Mini Sectt. Distt. Kaithal.
2025_HRY_422936_1
20252818BD39 52D0 40ED AFB9 9D92040FCD77665BAR
Open Tender
Electrical Works
Works
60 days
Kaithal
2 documents required · 2 mandatory
₹5,000
₹71,320
Yes
7 Apr 2025
10 Jan 2025
21 Jan 2025
13 Jan 2025
20 Jan 2025
13 Jan 2025
Amount
[24.2.7.7]LT CABLE 7.7. Supply and erection of suitable compression type brass cable glands for underground Cable :- 300 sqmm to 400 sqmm Cable 3 to 3½ Core [Through Rate]
[24.2.8.14]LT CABLE 8.14. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work.300 sqmm [Through Rate]
[24.2.8.2]LT CABLE 8.2. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 4 sqmm to 6 sqmm [Through Rate]
Supply of Three Phase 400 KVA (CPCB-IV plus ), Diesel Generating Set with AMF Panel comprising of: A. DIESEL ENGINE: 4 Cylinder, liquid cooled, Turbocharged After cooled, developing 75.5HP at 1500 RPM. This is electric start, compression ignition, 4 stroke engine design to run continuously 1500 RPM. Diesel conforms to present CPCBIV plus norms. The diesel engine comprise of following: • Radiator with Fan • G3 as per ISO 8528 Part V class governor • Dry type Air cleaner with service indicator • Lube Oil and Fuel filter • First fill of lube oil and coolant. (Make: Stamford/LS/CG/Meccalte Panel Type : ECP Panel) ALTERNATOR: 1. Electric starter motor with soft starting system • Battery charging alternator • CRDI System • DOC • 2 X 12V DC battery B. Alternator, suitable for continuous operation rated at 1500 rpm 415.00V, 0.80PF, 50.00Hz, Ph. in SPDP enclosure, self-excited, self-regulated Brush less, floor mounted an AVR. The alternator conforms to IS:133645, IS/IEC 60034-1 and will be suitable for tropical condition. 2. ± 0.5% Voltage regulationon in static conditions. 3. IP: 23 protections with class `H/F` insulation and temprature limited to class `H/F` insulation limited. 4. Permanent lubricated sealed bearing. 5. Permissible overload of 10% for 1 hour in 12 hours of operation. CANOPY SPECIFICATION: (Operational from 1010 KVA Onwards) 1. The enclosure is fabricated out of CRCA sheet. 2. The sheet components are not dipped in Tanks pre-traeted before powder coating. 3. The doors are gasketed with high quality EPDM gaskets to avoid leakage of sound. 4. The rock wool is further covered with fiber glass cloth and perforated powder coated ms sheet. 5. The sheet metal components are 9 tanks pre-treated and is Polyester based powder coated (inside as well as outside) for long life.CONTROLLER (DEIF / DSE / Woodward / ComAp): CONTROL1. Run/Off / Auto Switch 2. Emergency Stop 3. Manual run/ Stop Control switch 4. Idle/ Run mode control METERING ENGINE 1. Starting Battery Volatge 2. Lube oil Temp. and Pressure 3. Engine Coolant Temp. 4. Engine RPM 5. operating Hours 6. Number of Starts ELECTRICAL 1. Current 2. Voltage 3. Frequency 4. Killo Watt /KWh 5. PF/KVA, PROTECTION AND WARNING SYSTEM 1. Over speed shutdown 2. Low lube Oil pressure warning/ shutdown 3. High coolant Temprature Warning/Shutdown 4. Low coolant Temprature warning 5. Low coolant level warning /Shutdown 6. Low and High Battery voltage warning 7. Weak battery warning 8. Over crank shutdown 9. Fail to crank shutdown, ALTERNATOR 1. Over Current High Volatge 2. Low Voltage Under/Over 3. Frequency Reverse Power 4. (KVA and KVA) Phase Sequenc. including the cost of 100 Ltr. Diesel, 100 Ltr. Diesel Tank Make Mahindra/ Kirlosker/ Boudin/ Greaves Cotton/ Cummins
Supply and erection of 32 sq mm copper tape including making necessary connection etc. complete with all labour and material to complete the job in all respect up to the entire satisfaction of Engineer in Charge of the work.
Buy Back of 250 KVA DG Set including Loading/ Unloading, Dismantling and all labour charges.
S.S. Enterprises (BID ID -1203326)
Janta Electric Store (BID ID -1203349)
M/s JSB Enterprises (BID ID -1203487)
M/S PANJETA ELECTRICALS (BID ID -1203515)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .