Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹19.4 LAccepted-AOC | L-1 | Accepted-AOC Being L-1 | |
| 2 | L-2₹19.9 L+₹53,060 (2.74%)Rejected-Finance | L-2 | Rejected-Finance Other than L-1 | |
| 3 | L-3₹20.3 L+₹90,192.50 (4.66%)Rejected-Finance NEAR RAILWAY CROSSING ADAMPUR DOABA JALANDHAR JALANDHAR PUNJAB 144103 | JALANDHAR | PUNJAB | 144103 | L-3 | Rejected-Finance Other than L-1 | |
| 4 | L-4₹20.9 L+₹1.6 L (8.03%)Rejected-Finance | L-4 | Rejected-Finance Other than L-1 | |
| 5 | L-5₹20.9 L+₹1.6 L (8.18%)Rejected-Finance | L-5 | Rejected-Finance Other than L-1 |
Tender Value
₹23.5 L
EMD Value
₹47,060
Closing Date
27 Sept 2021, 6:00 pmClosed
Sh A K Dubey, IDSE , SE CWE
Military Engineer Services, Commander Works Engineer, Udhampur, PO - Garhi, Udhampur-182121
PROVN OF ADDN/ALTN OF BLDG NO T-01 AND RETAINING WALL WITH DRAINAGE AND REPLACEMENT OF SEWAGE LINE NEAR BLDG NO P-66, BIKRAM ENCLAVE UNDER GE (SOUTH) UDHAMPUR
2021_MES_469049_1
CWE/U(S)-47/2021-22
Open Tender
Civil Works
Item Rate
180 days
Udhampur
AS PER TENDER
7 documents required · 7 mandatory
₹500
GE (South) Udhampur
₹47,060
Yes
26 Nov 2021
18 Aug 2021
29 Sept 2021
18 Aug 2021
27 Sept 2021
15 Sept 2021
Amount
Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings, complete all as specified and as directed by Engr-in-Charge.
Pre-painted coloured corrugated profiled Galvalume/Zincalume sheet with min 0.50mm TCT with BTM of 0.45mm thick conforming to IS -513(AZ-150 GSM,Al Zn alloy metallic coating 550MPA yield stress as per AS-1397),as in roof covering/clading to wall fixed with self taping screws, colour/exterior coat of silicon modified polyster/ BHP x RW paint system 20 micron top coat applied over 5 micron primer and a micron polyster back coat applied over 5 micron primer,all fixed with galvanised self drilling self tapping fastener(12-14x55 with EPDM seals), complete all as specified and directed
Pre-painted coloured plain steel profiled Galvalume/Zincalume sheet with Min 0.50 mm TCT with BTM of 0.45mm thick conforming to IS-513(AZ-150 GSM, Al Zn alloy metallic coating 550 MPA yield stress as per AS-1397) as roof ridge colour/exterior coat of silicon modified polyster/BHPxRW paint system 20 micron top coat applied over 5 micron primer and a 5 micron polyster back coat applied over 5 micron primer ,all fixed with Galvanised self drilling self-tapping fastener (12-14x55 with EPDM seals) complete all as specified and directed.
S&F MS flat iron as in wind ties etc., confirming to Fe- 410 or 310-0 including iron clamps, complete all as specified and as directed by Engr-in-Charge.
Dismantling timber scantlings 40 sq. cm and over in section, in any position as in unframed work, complete all as specified and as directed by Engr-in-Charge.
Mild steel Rolled sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails guides for sliding doors, and vertical posts of pipes sections fixed with angle cleats or other connecting plates, Fe-410-W (Gde - E -250) complete all as specified and as directed by Engr-in-Charge.
Dismantling wall and ceiling boards (fibre pulp, insulation etc) or insulation boards / slabs / blankets, any thickness, including cover fillets, complete all as specified and as directed by Engr-in-Charge.
4mm thick Cement fibre E-board (designer false ceiling) of size 600mm x 600mm panel conforming to IS 14862 type B category three including GI frame work with size of grid 605mm x 605mm including all accessories and GI frame work for seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 to 30 mm and web of 27 mm fixed to surrounding wall using screws at 452 mm C/C, channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45mm suspended from soffit at approx 900mm C/C with GI cleat and steel expansion or suitable hanging from soffits/trusses/bracket supporting hanger compressing of GI wire, fibre E-board fixed to GI grid work with screws and applying to coats of distemper and one coat of primer applying on new surfaces, the fibre sheet should be fire resistant, water resistant, termite resistant, environment friendly & 100% asbestos free, complete all as specified and as directed by Engr-in-Charge.
Mild steel, 1.25mm thick plain, Plain, black, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed), fixed in repair, complete all as specified and as directed by Engr-in-Charge.
Dismantling structural steel work including doors, gates but excluding framed truss etc. complete all as specified and as directed by Engr-in-Charge.
Demolition of Cement Concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed by Engr-in-Charge.
75mm thick Plain cement concrete 1:5:10 type E-2 (using 40mm graded crushed stone aggregates) as in sub base to floor, complete all as specified and as directed by Engr-in-Charge.
25 mm thick, Plain cement concrete 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregates) as in sub base for laying floor finishes including finishing the surfaces even and rough without using extra cement complete all as specified and as directed by Engr-in-Charge.
Machine cut kota stone slab flooring 18-20 mm thick as in flooring, stair case and similar work over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including Screed bed or bedding layer of mortar 20mm thick in cement mortar 1:3, complete all as specified.
Description all as per srl item No 14 above but in vertical surfaces like dado/skirting, etc., set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10 mm thick rendering (backing) on fair faces of brick/concrete surfaces works in cement mortar 1:3, complete all as specified and as directed by Engr-in-Charge.
Non skid, coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match over & including 15mm thick screed bed or bedding layer in cement mortar 1:4, complete all as specified and as directed by Engr-in-Charge
Glazed coloured ceramic jointfree/rectified tiles of size 600x300mm / 450x600mm / 600x600 and 6 to 7mm thick in vertical surfaces like dado/skirting, etc., set and jointed in neat cement slurry and pointed in coloured cement to match with the color of tile etc., over and including 10 mm thick rendering on fair faces of brick/concrete surfaces works in cement mortar 1:3 finished rough for receiving tiles, complete all as specified and as directed by Engr-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by Engr-in-Charge.
Providing 50 mm thick cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregates as in plinth protection laid in alternate bays (n exc 2 Sqm each ) and finished even and smooth without using extra cement and providing joints through out the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified.
Demolition of brick work or stone masonry built in cement mortar including all quoins arches, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified and directed by Engr-in-Charge.
Brick work with old size sub class 'B' bricks, straight or curved on plan to any radius built in cement mortar 1:6, complete all as specified and as directed by Engr-in-Charge.
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, removing all type of vegetation (like peeple tree etc) scrubbing down with water complete, all as specified and as directed by Engr-in-Charge.
15 mm thick rendering in two layer (10mm + 5mm) on fair faces of brick /concrete on wall including facia chhajja etc.surfaces in cement mortar 1:4 and finished even and smooth without using extra cement including mixing Liquid water proofing compund in the proportion as mentioned in manufacturer's instructions complete all as specified and as directed by Engr-in-Charge. Note : Water proofing compund to be measured and paid for separately as supply only.
10mm thick rendering on fair faces of brick or concrete surfaces in cement mortar 1:6, finish surfaces even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
Applying two coats of oil bound distemper over and including a coat of primer including preparation of new plastered/ unplastered surfaces of wall, complete all as specified & directed by Engr-in-Charge.
Preparing newly plastered or unplastered surfaces of wall and applying two coats of cement base paint over a coat of primer, complete all as specified and as directed by Engr-in-Charge.
Applying two coats of oil bound distemper over and including preparation of old plastered/ unplastered surfaces of wall, including complete removal of existing treatment complete all as specified & directed by Engr-in-Charge.
Complete removal of existing treatment and applying two coats of cement based paint on old decorated or undecorated wall surface, complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 square metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt. ) , complete all as specified and directed by Engineer-in Charge.
Description all as per item No 29 above but area exceeding 1.50 square metre and not exceeding 4 square metre each.
Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube in opening as per specification & drawing, complete all as specified and as directed by Engr-in-Charge.
Factory made solid panel PVC door shutter 30mm thick style consisting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width struck inside with solvent cement forstyle and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the styles & rails with suitable PVC sheet beading and jointed together with solvent cement supply & fixing in the frame at site complete all as specified.
Steel window (box type) factory made with side hung shutters including pintol hinges, steel handles, steel peg stay and all locking arrangement complete with glazing bars dovetailed or welded including one shop coat of red oxide primer complete all specified and as directed. Note : i) The window shall be fabricated as per Drg No CEUZ/TD/1269/2008 Sheet 1/3 to 3/3 (ii) MS fillets, glazing, wire gauge shall be measured and paid separately.
Description all as per item above No 33 but without glazing bar complete all as specified and as directed.
Mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bar, barred iron doors; ladder, framed balusters; railing; frame work for water tanks, cooler stand etc and similar work conforming to FE 290 Gde-E-165, complete all as specified and as directed.
Preparation of new steel and iron surfaces exceeding 10cm width or girth and applying two coats of synthetic enamel paint over preprimed surfaces, complete all as specified and as directed by Engr-in-Charge.
Pressed steel frames for doors, made out of 1.25 mm thick MS sheet, with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc. complete, of frame size 125 mm x 60 mm, including one shop coat of red oxide zinc chrome primer, including filling voids with PCC 1:3:6 type C-0 complete all as specified and as directed by Engr-in-Charge.
35mm thick, factory made 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete, all as specified and directed by Engr in Charge.
Preparation of new wooden or wood based surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and as directed by Engr-in-Charge.
Preparation of new steel surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over a coat of red oxide chrome primer, complete all as specified and as directed by Engr-in-Charge.
Mild steel cold rolled butt hinges (ISI Marked) 'Medium weight' 100 mm size, fixed to steel/angle iron frame by welding , if required complete all as specified and directed by Engr-in- Charge.
200mm long, aluminium anodised, barrel tower bolts (ISI Marked) of extruded section and fixed, complete all as specified and directed by Engr-in- Charge.
150 mm size extruded aluminium alloy handles (ISI Marked), fabricated type., anodised, complete all as specified and directed by Engr-in- Charge.
300 mm long aluminium alloy, anodised, sliding door bolt (ISI Marked) with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and as directed by Engr-in-Charge.
300 mm long mild steel ordinary rat tail rod pattern door spring including roller and roller plate, fixed to frame, complete all as specified and as directed.
3mm thick Sheet glass, ordinary quality and glazing with oil putty in square or rectangle, area n exc 0.5 sqm in each pane, complete all as specified and as directed by Engr-in-Charge.
Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples, complete all as specified and as directed by Engr-in-Charge.
Vitreous China wash down water closet pan and seat cover (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including P or S trap and including plastic water closet seat, black, closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device, including connection to drain pipe (or out going pipe) and to flushing pipe, antisyphonage pipe, etc. including cast iron 'P' or 'S' trap for 100mm bore of pipe, fixed in repairs complete all as specified and as directed by Engr-in-Charge.
10 ltr capacity PVC valveless, symphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets with twin flush provision, fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
Plastic water closet seat cover, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device, complete all as specified and as directed by Engr-in-Charge
Vitreous China wash basin, pedestal type, white, flat back ,size 550x400mm excluding tap, chain, plug but, waste fitting 32mm dia ,brass chromimium plated for glazed ware sink, basin with pedestal, fix in repair, complete all as specified.
Bib taps , fancy type cast copper alloy, chromium plated, with crutch or butterfly handle screwed down for iron pipe or for brass ferrule for bore of pipe 15 mm fixing in repair, complete all as specified and as directed by Engr-in-Charge
Angle valves, fancy type chromium plated cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of bore 15mm with adjustable flanges, fixed in repair, complete all as specified and as directed by Engr-in-Charge.
Soap dish, stainless steel, approximate size 160x 160x90mm fixed to plugs with chromium plated brass screws, complete all as specified and as directed by Engr-in-Charge.
Tubular towel rails brass chromium plated, 20 mm dia, D type, 60 cm long between flanges, fixed with rawl plugs fixed in repairs complete alll as specified and as directed by Engr-in-Charge.
Shelf of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 300gms) complete all as specified by Engr-in-Charge.
Dismantling cast iron pipe & reinforced concrete drain pipes, jointed in cement mortar of any dia taking out from trenches or fixed to wall upto 100mm complete all as specified.
110mm bore, PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls, complete all as specified and as directed by Engr-in- Charge.
PVC (SWR) floor trap plain of size 75mm , with grating including jointing with solvent cement, fixing in repair, complete all as specified and as directed by Engr-in-Charge.
75mm bore, PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls, complete all as specified and as directed by Engr-in- Charge.
75 mm bore PVC SWR bends any radius with acess door and fixed with solvent etc complete all specified and as Directed (ISI Marked)
PVC (SWR) gully trap 125/110 mm setting and jointing with solvent cement, fixing in repair, complete all as specified and as directed by Engr-in-Charge
Taking up or down 15mm bore steel tubing and connections including all fittings and removing to store.
Taking up or down 20mm bore steel tubing and connections including all fittings and removing to store.
15mm bore galvanised steel water tubing medium grade (ISI Marked) with and including all fittings and fixed complete to walls and or laid under floors etc complete all as specified.
20mm bore galvanised steel water tubing medium grade (ISI Marked) with and including all fittings and fixed complete to walls and or laid under floors etc complete all as specified.
Rotational moulded polyethylene water storage tank , two layers, ISI marked (cylinderical vertical with closed top) hoisted with Threaded Cap and fixed in position all as specified in SSR Part-I of Capacity 1000 litres each including all accessories (i.e GI nipples and Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of bore 20mm (Minimum weight 210 gram) etc), incl dismantling existing water tanks, complete all as specified and as directed by Engr-in-Charge.
Gun metal globe or gate valve with iron wheel head, screwed both ends of size 20mm fixing in repair, complete all as specified.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in any type of Soil, complete all as specified and as directed by Engr-in-Charge.
75mm thick Plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) as in sub base to floor, complete all as specified and as directed by Engr-in-Charge.
Factory made, Machine pressed / vibro mechenically floated coloured interlocking cement paver block ISI marked, any shape and size conforming to IS 15658-2006 of 60mm thickness, M-35 Grade, with topping of cement with imported pigment including 30 mm thick sand cushioning bed including spreading levelling watering if required, Shape shall be approved by Engr-in-Charge.
35mm thick factory made flush shutters solid core construction with block board core and plywood face panels, incl 1.5mm thick decorative laminates on both faces. , complete all as specified and directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and as directed by Engr-in-Charge.
Machine pressed (factory made) precast plain cement concrete 1:2:4 type B-1 (20mm graded crushed stone aggregate) as in kerb stone of size 300mm x 300mm x 100mm thick, including setting in CM 1:4, complete all as specified and as directed by Engr-in-Charge.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, for laying cables/pipes, etc. not exceeding 10 sq m on plan and not exceeding 1.5 m in depth in any type of soil and getting out soil, complete all as specified and as directed by Engr-in-Charge.
Returning, filling in (soil) including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any type of soil, complete all as specified and as directed by Engr-in-Charge.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and as directed by Engr-in-Charge.
Plain cement concrete (1:4:8) type D2 using 40mm graded stone aggregate as in foudation, filling, sub base and mass concrete all as specified.
300mm bore salt-glazed stoneware drain pipes of grade 'A' laid in trenches and jointed as specified, complete, complete all as specified and as directed by Engr-in-Charge.
Plain cement concrete 1:3:6 type C-2 (using 40mm graded aggregate) as in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 300mm bore pipes all as specified. Note:-(i) Thickness of bed below barrel of pipe-10 Cms. (ii) width of bed- outer dia of pipe plus 30 cms.
Providing, Plain cement concrete 1:2:4, type B-1 (using 20 mm graded stone aggregates) in roof kerbs or mud stops, rounded or chamfered on edges, all as specified .
S&F SRFC manhole cover size 600mmx600mm diax70mm thick with frame, sides protested by angle iron, set in cement mortar 1:4 complete all as specified and as directed by Engr-in-Charge. Note (i) Make SRFC manhole/drain cover and frame : (a) PC concrete. (b) M/S K K manhole (c) Or equivalent as approved by GE (ii) Contractor will provide manufacture test certificate of SRFC cover & frame.
Brick work with old size sub class 'B' bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:4, complete all as specified and as directed by Engr-in-Charge.
Plain cement concrete 1:2:4 type B-2 (using 40mm graded crushed stone aggregates) as in surface channels and drains, complete, complete all as specified and as directed by Engr-in-Charge.
Providing cement concrete 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) in steps, seismic and other similar bands, parapets and railings up to 60 cm in hieght, coping, kneeless apex stones , bed plates, roof padding, kerbs not provided for including weathering, slightly rounded or chamfered angles including necessary formwork complete all as directed and specified.
Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted , built in cement mortar 1:6 complete all as specified and as directed.
Description all as per item above No 87 but without except stone complete all as specified and as directed. NOTE for Item No 87 & 87.1: The net qty of masonary shall be derived after deduction of volume of precast PCC bond stone adjustment.
Plain cement concrete 1:2:4, type B-1 (using 20 mm graded crushed stone aggregates) as in steps, seismic and other similar bands, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, cills, lintels upto 1.50 metre clear span, copings, kerb etc. and in similar works including weathering, slightly rounded or chamfered angles and throating and necessary form works, complete, all as specified and directed by Engr-in-Charge.
Providing, pre-cast cement concrete 1:3:6 type C-I (using 20mm graded crushed stone aggregates) as in bond stones and in similar works bedded and jointed in cement morter 1:6, complete all as specified and as directed by Engr-in-Charge.
Boulder filling dry ,hand packed tightly , as in wire crate apron bunds, complete all as specified and as directed by Engr-in-Charge. (wire crate shall be measured seperately )
Raised pointing to random or polygonal rubble, uncoursed or brought upto courses stone masonry in Cement Mortar 1:4 complete all as specified and as directed by Engr-in-Charge.
PVC pipe 110mm bore single socket in any length as in weep holes all as specified and as directed by Engr-in-Charge.
Taking down carefully copper /aluminium, point wiring (light, fan, socket or power) complete including fittings and fixtures such as light fittings, switches, ceiling roses, pendants, regulators, sockets etc. and making good disturbed surfaces of wall, ceiling, floors etc, complete all as specified and as directed by Engr-in-Charge.
Point wiring with 1.5 Sqmm PVC insulated, unsheathed (FRLSH) cable with multi stranded copper conductor wiring in and including PVC concealed conduit (ISI marked) 20mm dia and over, medium grade and all accessories for one light / fan controlled by one switch suitable for pressed GI terminal boxes (modular type) of required modules concealed on walls including inner and outer sheet for fixing of modular switches/socket/ regulator etc along with PVC insulated and unsheathed FRLSH 1.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly, complete all as specified & directed by Engr-in-Charge. Note: Modular metal flush boxes & cover plates deemed to be included inquoted rate.
Description all as per item No 94 above but 05 Amp socket outlet controlled by one switch on independent board .
Description all as per item No 94 above but 05 Amp socket outlet controlled by one switch on same board with other switch.
Description all asper item No 94 above but one 3/5 pin 15 Amp socket outlet on independent board with PVC insulated, unsheathed FRLSH cable 2.5 Sqmm copper multistrand conductor, along with PVC insulated and unsheathed FRLSH 2.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly complete all as specified and as directed by Engr-in-Charge.
Description all as per item No 94 above but one 3/5 pin 15 Amp socket outlet on independent board with PVC insulated, unsheathed FRLSH cable 4 Sqmm copper multistrand conductor, along with PVC insulated and unsheathed FRLSH 4 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly complete all as specified and as directed by Engr-in-Charge.
S&F Modular Switch ,one way ,06 Amps, 230 volt, 50 Hz , complete all as specified and as directed by Engr-in-Charge.
S&F Modular Switch ,one way ,16 Amps, 230 volt, 50 Hz , complete all as specified and as directed by Engr-in-Charge.
S&F Modular Socket outlet, ,06 Amps, 230 volt, 50 Hz, complete all as specified and as directed by Engr-in-Charge.
S&F Modular Socket outlet, ,16 Amps, 230 volt, 50 Hz, complete all as specified and as directed by Engr-in-Charge.
S&F Ceiling rose, surface bakelite 65x 50mm two to three terminals fixed on PVC Round Block, complete all as specified and as directed by Engr-in-Charge.
S&F Stepped type fan regulator 120W, 230V 50 C/S, 2 module, Deluxe Modular type electronic, hum free suitable control speed of fan from 0 to 100 % and connecting electrically, fixed in repair, complete all as specified and as directed by Engr-in-Charge.
Taking down carefully existing ceilling/exaust fan any type sweep and removing fan blade including Painting, oiling, fan capacitor & cleaning all dust particles and filling cavities with filler material, oiling, greasing including painting fan with blade complete one coat of synthetic enamel white paint by spraying and assemble the same along with all fixing connecting accessories and fixing the same position along with all new electrical wire connection complete all as specified and as directed by Engr-in-Charge.
S&F Decorative ultra slim linear surface mounted LED lighting fixture (4 feet length), 20Watt LED with integral electronic driver , fixed in repair, complete making connection and testing after fixing all as specified and directed by Engr-in-charge.The specification of light fitting should meet the following : - (a) Housing of Light fitting : Aluminium Extruded (b) Operating Voltage : Between 150 V- 270V (c) Operating Temperature : -10 to +45 Degree Centigrade (d) Lumen efficacy : Not less than 110 lm/W (e) System Lumens : Not less than 2000 lm (f) Colour Temperature : Not less than 5700K (g) Surge Voltage Protection : Up to 2KV (h) Ingress protection : IP 20 (j) Total Harmonic Distortion (THD) : Not less than 20% (k) Power factor : Not less than : 0.90 (l) Line protection : Under/Over voltage Protection (m) Input Frequancy : 50 Hz
S&F Environmental friendly, energy saving, surface mounted, decorative LED 10 Watt Bulk head luminaire, with integral electronic LED driver with APFC and lower THD, fixed in repair, Output complete making connection and testing after fixing all as specified and directed by Engr-in-charge.The specification of light fitting should meet the following :- (a) Housing of Light fitting : Die Cast Aluminium (b) Diffuser : Polycarbonate UV protected diffuser (c) Operating Voltage : Between 140 V- 270V (d) Operating Temperature : -10 to +45 Degree Centigrade (e) Lumen efficacy : Not less than 100 lm/W (f) System Lumens : Not less than 900 lm (g) Colour Temperature : Not less than 5700K (h) Surge Voltage Protection : Up to 4kV (j) Ingress protection : IP 65 (k) Total Harmonic Distortion (THD) : Not less than 20% (l) Power factor : Not less than : 0.9 (m) Line protection : Under/Over voltage Protection (n) Input Frequancy : 50 Hz
Supply and fixing wall mounted LED Decorative luminaire with suitable for 10 watt LED, B-22, fixed in repair, including 1x10 watt LED Lamp retrofit type, B22 with all fitting and acessories complete making all connections using 1.5 Sqmm copper conductor multistrand PVC insulated 2 core flexible cable from ceiling rose to fitting complete all as per the directions of Engg-in-Charge. Note : (i) A certificate from the manufactures for warranty minimum upto 3 years shall be obtained and submitted to the AGE/GE (ii) Any touch up of the wall surface due to changing of fittings shall be done by contractor with similar surface finish without extra cost to the department.
Material & Labour for Sub main wiring with two runs of 10 Sqmm ( 2x10 sqmm ) 1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor conforming to IS-694 drawn through and including non-metalic PVC rigid conduit 25 mm dia medium grade (ISI marked) with all conduit accessories mounting on suface of walls /roofs / ceiling etc with one run of 10 Sqmm (1x4sqmm ) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire, fixed in repair, complete all as specified and directed by Engr-in-Charge. Note:- 2 runs of 10 Sqmm (2x10sqmm ) ,one run of 10 Sqmm (1x10 sqmm ) cable and one metre of conduit will be measured as one unit.
Material & Labour for Sheet metal enclosure single pole & neutral with 2 pin and earth plug and socket 20Amps, 240V complete with one single pole MCB of any cap from 10 to 20 Amps of breaking capacity 10KA, fixed in repair, complete all as specified and as directed by Engr-in-Charge.
Material & Labour for Sheet metal enclosures for distribution board when MCB to be used SPN 8 way with IP-43, IK-09 protection 240V with 200 Amps rated bus bar, double door type including cutting chases in walls for fixing DBs making good the distubed surfaces to match with existing specifications ,fixing in repairs complete all as specified and as directed.
S&F MCB SP, 6 to 32 Amps, 'B' series 10 KA 240 Volts including providing aluminium thimbles for outgoing cable, fixed in repair, complete all as specified and as directed by Engr-in-Charge. Note : The exact capacity of MCB shall be as directed by Engr-in-Charge.
S&F MCB SPN, 40 to 63 Amps, 240 Volts, rupturing capacity 10 KA "C" Series including providing aluminuium thimbles for outgoing cable, fixed in repair, complete all as specified and as directed by Engr-in-Charge. Note : The exact capacity of MCB shall be as directed by Engr-in-Charge.
S&F MCB TPN, 63 Amps, 240 Volts, rupturing capacity 10 KA "B" Series including providing aluminium thimbles for outgoing cable, fixed in repair, complete all as specified and as directed by Engr-in-Charge.
S&F Sheet metal enclosures for distribution board when MCB to be used TPN 4 way 415V with 200 Amps rated bus bar, double door type with IP-43, IK-49 protection with appropraite size bus bar and neutral link fixed flush in wall including cutting chases in walls for fixing DB and making good disturbed wall surfaces to match the existing specifiactions ,fixing in repairs complete all as specified and as directed by Engr-in-Charge.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to and including 4mm dia galvanized iron wire lead by means of bolts, nuts, check nuts and washers of galvanized standard iron or steel all as specified or indicated in electrical plate No 3 of MES Part-I, including testing on completion including the material and labour and taking out old unserviceable earthing of the following :- (a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm. (d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified.
Srl item No 115 Contd … (e) 15 mm nominal bore light grade GI protection pipe 7.5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of earthing. Note : On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge.
Supply, laying and testing of XLPE insulated sheathed armored heavy duty LT 1100 Volts grade cable with aluminum conductors laid in trenches/pipe, fixed to poles, walls of size 25 sqmm 3.5 core including taking up/down old unserviceable cables. complete all as specified and as directed by Engr-in-Charge.
Supply and laying brick covering with width equal to length of brick as mechanical protection to cable using sub class ‘B’ bricks laid flat of size 230mmx115mmx75mm, complete all as specified and as directed by Engr-in-Charge.
Dry coarse sand as cushioning to under ground cable provided with layer of 8 cms deep before laying the cable and 15 cms deep after laying and stretching the cable, punned to 18 cm thick complete all as specified and as directed.
Supply and Fixing GI tubing light grade 25mm dia along the wall/in trenches/in duct/in culvert/road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holding of GI pipe alongwith poles , fixed in repair, complete all as specified and as directed by Engr-in-Charge.
S&F New generation energy saving and environmental friendly long life LED street light of 35 watt with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment and impact resistance of IK07 with High efficiency long life LED with SMD LED on MCPCB Powered by Built-in, isolated electronic LED driver (SMPS based constant current supply) complete making connection and testing after fixing, fixed in repair, complete all as specified and directed by Engr-in-charge. The specification of light fitting should meet the following : - (a) Housing of Light fitting : Aluminium Die Cast (b) Diffuser : High efficient LENS Optics (c) Operating Voltage : Between 150 V- 270V (d) Operating Temperature : -10 to +45 Degree Centigrade (e) Lumen efficacy : Not less than 100 lm/W (f) System Lumens : Not less than 2500 lm (g) Colour Temperature : Not less than 5700K (h) Surge Voltage Protection : Up to 4KV (j) Ingress protection : IP 65 (k) Total Harmonic Distortion (THD) : Not less than 20% (l) Power factor : Not less than : 0.9 (m) Line protection: Under/Over voltage Protection (n) Input Frequancy : 50 Hz
Street light Bracket complete made of GI pipe 40mm bore, light grade of suitable size, 1.2m long bent to shape as per site requirement alongwith MS flat iron clamps with nuts, bolts, washers including grouting the same with wall, fixed in repair, complete all as per the direction of Engg-in-Charge.
RAMAN CONSTRUCTION CO
M/S GURBACHAN SINGH
khajuria builders
RAJ MOHD
M/S ASHOK KUMAR PACHIALA
paras ram pachiala
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .