| 1 | L1₹77.3 LAccepted-AOC NO 229 ANGAPPAN STREET MITTANAMALAI AVADI IAF CHENNAI 600 055 | CHENNAI | CHENNAI | TAMIL NADU | 600055 | L1 | Accepted-AOC Being a lowest bidder | |
| 2 | L2₹85.6 L+₹5.9 L (7.38%)Rejected-Finance 203 1 THIRUMATHI SUNDARI ILLAM CHINNAMMEN KOIL STREET AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | L2 | Rejected-Finance Being a 2nd Lowest bidder | |
| 3 | L3₹87.9 L+₹8.2 L (10.2%)Rejected-Finance NO 14 M C RAJA STREET MITTANAMALLI I A F AVADI CHENNAI 600 055 | CHENNAI | CHENNAI | TAMIL NADU | 600055 | L3 | Rejected-Finance Being a 3rd lowest bidder | |
| 4 | L4₹89.0 L+₹9.3 L (11.6%)Rejected-Finance | L4 | Rejected-Finance Being a 4th lowest bidder | |
| 5 | L5₹96.9 L+₹17.2 L (21.6%)Rejected-Finance HOUSE NO 105 PANTHEERMA VILLAI NEAR NELLIKKAVILLAI CSI CHURCH VELLAYAMBALAM VENCODE P O KANYAKUMARI DIST TAMIL NADU 629 171 | VENCODE | KANYAKUMARI | TAMIL NADU | 629171 | L5 | Rejected-Finance Being a 5th lowest bidder |
| Sl No | Description | Qty | Unit | DJ Group L5 | pmv.enterprises L2 | DANUSH INTERIORS AND CONTRACTORS L6 | SAMYDOSS CONSTRUCTIONS L3 | muthu constructions L1 | M/s Omm Muruga Enterprises L4 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00B/R PORTION : | |||||||||
| 1.01 | M&L for complete removal of existing water proofing treatment from the existing roof including concrete levelling course of any thickness and description and cleaning the surfaces with wire brushing, watering and removing debris to a distance not exceeding 1500 metre complete all as specified and directed. | 1,000 | Sqm | 35 ₹35,000 | 36 ₹36,000 | 50 ₹50,000 | 20 ₹20,000 Lowest | 29 ₹29,000 | 39 ₹39,000 |
| 2.00 | M&L for plain cement concrete 1:2:4 type B0 using 12.50 mm graded stone aggregate 25mm thick as in roof levelling course mixed with integral water proofing compound as per Manufacturers instructions complete all as specified and directed.
Note:- WPC shall be measured and paid seperately under relevant item. | 1,000 | Sqm | 189 ₹1,89,000 | 144 ₹1,44,000 | 200 ₹2,00,000 | 120 ₹1,20,000 Lowest | 149 ₹1,49,000 | 249 ₹2,49,000 |
| 3.00 | M&L for plain cement concrete 1:2:4 type B0 using 12.50 mm stone aggregate as in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed. | 5 | Cum | 6,000 ₹30,000 | 4,500 ₹22,500 | 8,000 ₹40,000 | 5,000 ₹25,000 | 2,999 ₹14,995 Lowest | 5,699 ₹28,495 |
| 4.00 | M&L for rendering 10mm thick in cement mortar 1:3 mixed with integral water proofing compound as per Manufactures instruction on concrete surfaces of roof finished even and smooth without using extra cement to recive water proofing membarane complete all as specified and directed. Note:- WPC shall be measured and paid seperately under relevant item. | 1,000 | Sqm | 181 ₹1,81,000 | 144 ₹1,44,000 | 250 ₹2,50,000 | 120 ₹1,20,000 Lowest | 129 ₹1,29,000 | 229 ₹2,29,000 |
| 5.00 | Supply only liquid water proofing compound | 50 | Litre | 122 ₹6,100 | 90 ₹4,500 | 75 ₹3,750 Lowest | 90 ₹4,500 | 99 ₹4,950 | 260 ₹13,000 |
| 6.00 | M&L for applying evenly a priming / tack coat with bituminous primer at 10 kg per 10 sqm complete all as specified and directed. | 100 | X Sqm | 250 ₹25,000 | 270 ₹27,000 | 150 ₹15,000 | 50 ₹5,000 Lowest | 199 ₹19,900 | 390 ₹39,000 |
| 7.00 | M&L for prepartion of the plastered surfaces by thoroughly removing all loose particles, dirt/ dust particles and applying a uniform coat of hot blown bitumen of grade VG-10 @ 1.20 kg/sqm confirming to IS 702 over a coat of water based bituminous primer @ 0.40 litre / sqm and laying APP based polymeric membrane as per IS 16540-2017/ IS 16532-2017 with overlap of 100mm minimum weighing 3.6 kg/ sqm and minimum 3mm thick reinforced with polyester non woven fabric (weight not less than 150gms/ sqm) by forced application and finally finsihed the memberance surface by applying a coat of solar refelective aluminium paint @ 0.1 litre /sqm complete all as per Manufacturer's instructions and as diected Note:- WPT shall be executed through authorised apllicator of original Manufatcurer | 1,000 | Sqm | 480 ₹4,80,000 | 351 ₹3,51,000 | 500 ₹5,00,000 | 400 ₹4,00,000 | 339 ₹3,39,000 Lowest | 349 ₹3,49,000 |
| 8.00 | S&F Rotational moulded polyethylene water storage tanks 1000 litres capacity ,three layered (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified in SSR Part I | 5 | Each | 9,001 ₹45,005 | 7,200 ₹36,000 Lowest | 11,000 ₹55,000 | 9,000 ₹45,000 | 7,999 ₹39,995 | 7,999 ₹39,995 |
| 9.00 | S&F Rotational moulded polyethylene water storage tanks 500 litres capacity ,three layered (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified in SSR Part I | 5 | Each | 4,500 ₹22,500 Lowest | 4,500 ₹22,500 Lowest | 5,500 ₹27,500 | 4,500 ₹22,500 Lowest | 4,999 ₹24,995 | 4,500 ₹22,500 Lowest |
Tender Value
₹1.2 Cr
EMD Value
₹1.9 L
Closing Date
17 Dec 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri Vishal Garg,IDSE,SE,SAG
CWE Chennai Pallavan Sallai Chennai
ADDN / ALTN TO T/23, T/28 AND COOK HOUSE / DINING HALL OF AIRMEN MESS IN DC I AT 23 ED AF STN UNDER GE AVADI
2025_MES_740452_1
87766/E8
Open Tender
Civil Works - Others
Item Rate
180 days
GE Avadi
As per tender documents
8 documents required · 8 mandatory
₹1,000
GE Avadi
₹1.9 L
20 Feb 2026
19 Nov 2025
19 Dec 2025
19 Nov 2025
17 Dec 2025
10 Dec 2025
B/R PORTION :
M&L for complete removal of existing water proofing treatment from the existing roof including concrete levelling course of any thickness and description and cleaning the surfaces with wire brushing, watering and removing debris to a distance not exceeding 1500 metre complete all as specified and directed.
M&L for plain cement concrete 1:2:4 type B0 using 12.50 mm graded stone aggregate 25mm thick as in roof levelling course mixed with integral water proofing compound as per Manufacturers instructions complete all as specified and directed. Note:- WPC shall be measured and paid seperately under relevant item.
M&L for plain cement concrete 1:2:4 type B0 using 12.50 mm stone aggregate as in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed.
M&L for rendering 10mm thick in cement mortar 1:3 mixed with integral water proofing compound as per Manufactures instruction on concrete surfaces of roof finished even and smooth without using extra cement to recive water proofing membarane complete all as specified and directed. Note:- WPC shall be measured and paid seperately under relevant item.
Supply only liquid water proofing compound
M&L for applying evenly a priming / tack coat with bituminous primer at 10 kg per 10 sqm complete all as specified and directed.
M&L for prepartion of the plastered surfaces by thoroughly removing all loose particles, dirt/ dust particles and applying a uniform coat of hot blown bitumen of grade VG-10 @ 1.20 kg/sqm confirming to IS 702 over a coat of water based bituminous primer @ 0.40 litre / sqm and laying APP based polymeric membrane as per IS 16540-2017/ IS 16532-2017 with overlap of 100mm minimum weighing 3.6 kg/ sqm and minimum 3mm thick reinforced with polyester non woven fabric (weight not less than 150gms/ sqm) by forced application and finally finsihed the memberance surface by applying a coat of solar refelective aluminium paint @ 0.1 litre /sqm complete all as per Manufacturer's instructions and as diected Note:- WPT shall be executed through authorised apllicator of original Manufatcurer
S&F Rotational moulded polyethylene water storage tanks 1000 litres capacity ,three layered (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified in SSR Part I
S&F Rotational moulded polyethylene water storage tanks 500 litres capacity ,three layered (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified in SSR Part I
Disconnecting existing tank of 500 litres capacity , setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required, reconnecting and re-fixing in position complete all as specified and directed
Disconnecting existing tank of 1000 litres capacity , setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required, reconnecting and re-fixing in position complete all as specified and directed
S&F Ball valves, high pressure, PTMT with epoxy coated aluminium rod & high desity plastic ball screwed for iron pipe of 25 mm bore ( Minimum weight 455 gms ) and fixed complete all as specified and directed.
S&F gun metal globe or gate valve with iron wheel head screwed both ends for iron pipe of 15mm dia and fixed complete all as specified and directed.
Taking up or down steel tubing 15mm dia with connection including cleaning for refixing or removed to store complete all as specified
All as per item 14 above but for 20mm bore
All as per item 14 above but for 25mm bore
S&F Unplasticised PVC pipes and fittings of 15mm dia of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc. complete all as specified and directed
All as per item 17 above but for 20mm bore
All as per item 17 above but for 25mm bore
M&L for cutting chases or making holes in brick walls of girth not exc 10 cm for concealed water tubing and making good the disturbed surface and facings with existing finishes complete all as specified.
Taking down cement plaster of any description from brick wall or concrete surfaces including racking out joints and hacking for key, scrubbing down with water etc complete all as specified
M&L for rendering 10mm thick on concrete surface in cement mortar 1:3 and finished the surface even and smooth without using extra cement in ceiling complete all as specified and directed.
M&L for rendering 10mm thick on wall surface of brick work /concrete surfaces in cement mortar 1:6, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick on walls of brick / concrete sufaces ,5 mm thick rendering in cement mortar 1:4 mixed with WPC over and including 10 mm thick dubbing coat in cement mortar 1:6 ,finished the surface even and smooth complete all as specified and directed. Note: WPC shall be measured and paid separately under relevant item.
M&L for preparation of newly plastered ceiling surfaces and applying three coats of white wash complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall and applying three coats of white wash complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed.
Distmantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed.
S&F in repairs perforated particle board/ tiles for insulation and accoustic purposes, 600x600 mm x 12mm thickness in size, fixed with nails to timber framework or with staples on snap grid complete all as specified and directed.
S&F in repairs anodised aluminium snap grid frame work with standard aluminium section for false ceiling complete all as specified and directed.
S&F in repairs Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20mm and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and directed.
S&F in repairs hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat of size 40mm x 3 mm , 60mm long and expansion hold fasteners 12.5mm dia , 40mm long complete all as specified and directed.
S&F Non asbestos fibre cement building board as in false ceiling , manufactured from homogeneous mixture of cement, quartz and cellulose and cured with high pressure steam using auto claving process confirming to IS-14862, of size 600 mm x 600 mm x 4 mm thick fixed over snap grid frame work of T section (main & cross member) of size 25 mm x 25 mm x 1.5 mm thick in square pattern of grid size 600mm X 600mm . The aluminium fram work will supported on side wall with the used of aluminium 'L' section of size 25 mm x 25 mm x 1.5 angles etc. Snap grid shall be supported with hangers of 4 mm dia. Galvanised iron wire adjusting level fixed to roof slabs / truss etc by means of ceiling cleats made out of Galvanised iron flat of size 40 x 3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia 40 mm long complete all as specified and directed .Make : Everest or other equivalent as approved by GE
Dismantling plain or corrugated steel sheeting any guage, thickness including Nainital or similar pattern roof covering, complete all as specified and directed.
S&F in repairs prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 MPA as in roof covering/ cladding to wall fixed with self tapping screws all as specified and as directed.
S&F in repairs Pre-painted galvalume aluminium zinc coating GI based ridge with plain steel sheet 0.50mm of an colour having tensile strength of 550 Mpa as in roof covering fixed with self tapping screws complete all as specified and as directed.
S&F in repairs PVC (SWR) rain water pipes of 160 mm dia confirming to IS 13592 type 'B' including necessary rubber ring joints fix with velly gutter along wall or cleading complete all as specified
S&F PVC (SWR) bends 160 mm dia of any radius complete all as specified
Dismantling wrought iron or mild steel work of any description complete all as specified and directed.
S&F mild steel framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 etc complete all as specified
S&F Mild Steel hand rails, half round or other stock section or core for wooden hand rail straight portion, drilled and counter sunk for balusters running bars for doors, balusters, nosing to steps including embeding in concrete and screwing, etc,. wind ties for roof including securing bolts; post and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc., flat iron fillets (for securing wire mesh, etc.,), bolting or riveting, etc., and similiar work confirming to Fe-290 Gde E-165 complete all as specified
M&L for preparing new steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
M&L for preparing new steel surfaces of any description, not exceeding 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided and removing the debris off all as specified and directed.
M&L for plain cement concrete 1:4:8 type D2 using 40 mm graded granite stone aggregate as in sub base/ floor/ hard standing etc complete all as specified
M&L for sand filling under 60mm thick interlocking paver block complete all as specified and directed.
M&L for machine pressed precast concrete interlocking paver blocks of approved colour, design,shape,pattern and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade as in paving / foot path / hard standing etc ,made by table vibratory method using PU mould, laid over sand bed cushioni
ng through vibrartory compaction by using plate vibrator , filling the joints with sand and cutting of paver blocks as required size and pattern, finishing and sweeping extra sand including with watering and consolidation complete all as specified and as directed. NOTE:Sand cushioning shall be measured and paid separately under relevant item.
Taking down chowkhats or frames not exceeding 1.5 sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed.
Taking down chowkhats or frames exceeding 1.5 sqm but not exceeding 4.sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed.
S&F powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
S&F powder coated aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc.complete all as specified and directed.
S&F powder coated aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and directed.
S&F 5.5mm thick sheet glass, ordinary quality and glazing with oil putty in square exceeding 0.5 Sqm in each pane complete all as specified and directed.
S&F prelaminated particle board 12mm thick, interior grade, prelaminated one side with decorative choice lamination & other siode balancing white lamination fixed with screws to timber frame work complete all as specified and directed.
S&F in repairs vitreous china squatting pan, ‘Orissa’ pattern of size 580 mm x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) complete all as specified and directed.
S&F in repairs Vitreous china bowl urinal flat back of size 465 mm x 355 mm x 265 mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) complete all as specified and directed.
S&F in repairs PVC valveless, syphonic action type, flushing cistern,10 litres capacity, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and directed.
S&F Vitreous China wash basin, white, flat back, of size 550mmx400mm excluding taps, waste, chain and plug and porcelain stopper but including brackets cutting for and pinning in ends of brackets or erecting or fixing of supply and waste pipe complete all as specified
M&L for complete removal of existing treatment from old surface of walls including prepaing the surface by brooming down / steel wire brushing, scrapping down smoke soot, mould, moss and efflorescent salts and trading oil and greasy spoutes and cleaning with water on wall including smooth the surface with using white putty or paste filler and applying two coats of oil bound distemper over a coat of primer complete all as specified .
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for complete removal of existing treatment from old surface of walls including preparing the surface with brooming down / steel wire brushing, scrapping down smoke soot, mould, moss and efflorescent salts and trading oil and greasy spoutes and cleaning with water on wall surface including smooth the surface using white putty or paste filler and applying two coat of exterior grade paint weather resistant paint complete all as specified and directed.
M&L for coloured glazed ceramic tiles of size 350x 250x 7mm/ 450X 350X 7mm/ 450 x 300 x 7mm thick as in vertical surface such as dado,skirting etc set and jointed in neat cement slurry and pointed in colour cement to match with the shade of tiles over and including backing coat / rendering 10mm thick in CM 1:3 complete all as specified
M&L rendering 10mm thick on wall surface of brick work/concrete work in cement mortar 1:6, finished the surface even and smooth without using extra cement complete all as specified
M&L for plain cement concrete 1:4:8 type D2 (using 40 mm graded granite stone aggregate) 100mm thick as in sub base to floor hard standing etc.complete all as specified
M&L for chequred cement concrete tiles of size 300x 300 x25 mm thick ,mixed with grey cement and no pigment ,set, jointed and pointed in neat cement slurry in floors laid over and including 20 mm thick screed bed in CM 1:4 complete all as specified and as directed
M&L for light shade vitrified ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match with colour of tile complete all as specified .
M&L for plain cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in bed plates , foundations etc. complete all as specified
M&L for screed bed or bedding layer with 20 mm thick cement mortar 1:4 for laying floor finishes complete all as specified.
M&L for excavation in post holes each not exc 0.5 cum getting out in hard and dense soil including returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance not exc 50m and making good surface complete all as specified
S&F mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment of Fe-410-W (Gde-E-250) quality ‘A’ complete all as specified and as directed.
S&F mild steel work as in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161- 1979 grade St.-240 complete all as specified and directed.
Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in hard / dense soil complete all as specified
M&L for hardcore with broken stone or boulders of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified
S&F Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 of thickness 1mm complete all as specified and directed.
S&F in repair stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed
Taking down carefully unserviceable point wiring copper / aluminium (light, fan, socket or power) complete, including removal of batten / conduit / gutties / wooden board etc., including fittings and fixtures such as switches, ceiling roses, regulators, sockets, light fittings, fans etc.,removal from site under Sch of credit and removal of unserviceable items out of site and making good the disturbed surfaces of walls, ceilings etc.,complete all as specified and as directed.
one light point controlled by one switch.
INTERNAL ELECTRIFICATION:
M&L for point wiring on stone / brick masonry wall complete with two runs of 1.5 sqmm single core PVC insulated FRLSH ,1100 volts grade unsheathed cable confirming to IS-694, 1977 with multistranded copper conductor, drawn through and including non-metalic rigid PVC conduit, conduit fittings and conduit accessories not less than 20 mm dia concealed in walls and fixed with suitable clamps on ceiling / roof trusses etc., and including provision of one run of 1.5 sqmm PVC insulated single core multistranded copper conductor FRLSH green in colour as earth continuity conductor and connected to common earth dolly,including Modular boxes, frames and cover plates complete all as specified . Note : Quoted rate shall be inclusive for modular box, frame, cover plates and cutting chases for concealing the condit pipes etc for point wiring.
One ceiling fan point controlled by one switch and regulator
One Exhaust fan point controlled by one switch.
One switch socket outlet 3 pin 5 Amps on independent board.
One Air circulator fan point controlled by one switch.
All as per item No 78 here-in-before but for point wiring with two runs of 4.0 sqmm single core copper conductor multistranded FRLSH cable and one run of 4.
0 sqmm PVC insulated single core multistranded cable as earth continuity conductor green in colour including steel box of required module for modular switches/sockets for one 3 pin switch socket outlet, 15 Amps, complete all as specified and as directed.
S&F Modular switch 1 way 6A, 1 module complete all as specified.
S&F Modular switch 1 way16A, 1 module complete all as specified.
S&F Modular Socket, 6A - 2/3 pin combined 2 module complete all as specified.
S&F ceiling rose 65 X 50 mm , three terminals ,bakelite , surface complete all specified.
S&F Modular Socket, 6A/16A - 2/3 pin combined 2 module complete all as specified.
S&F Modular fan step regulator , 120w, 2 module complete all as specified.
S&F Single pole and neutral enclosure with a two pin and earth plug and socket with one single pole MCB 20 Amps complete all as specified.
S&F MCCBs125 Amps 415V,16KA, 4 Pole complete all as specified .
S&F MCB DB SPN 8 way, double door, powder coated, 240 volts, AC, 50Hz, IP 43 protected, with provision for MCB double pole as incomer and SP MCBs as outgoing with tinned copper bus bar, neutral link, earth link and connecting up complete all as specified and as directed. Note : Incoming and Outgoing MCB measured separately relevent items.
S&F Load line MCB DB TP&N 4 way, vertical, double door, powder coated, 415 volts, AC, 50Hz, IP 54 protected, fixed on wall semi flush with provision for FP MCCB 125Amps as incomer and SP MCBs 32 amps as outgoing with tinned copper bus bar, neutral link, earth link and connecting up complete all as specified and as directed. Note : Incoming MCCB and Outgoing MCB measured separately relevent items.
S&F 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified.
S&F 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and Neutral current carrying capacity 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified.
S&F Surface and wall mounted LED tube light fitting, 20 W, batten type, PC housing provided for efficient heat dissipation with polycarbonate diffuser and integrated electronic driver complete with all accessories , suitable for operation on AC, single phase 220/230 Volts,50 Hz supply, and including connecting up with PVC sheathed suitable copper conductor flexible wire from ceiling rose to fitting complete all as specified and as directed.
S&F Suspended / pendant type LED tube light fitting 40 Watt for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver complete with all accessories,suitable for operation on AC, single phase 220 / 230 Volts, 50 Hz supply with suspension arrangement of 1.5 m (02 Nos) parallel for fixing of fitting including taking down old fittings of any description complete all as specified.
Taking down carefully Power / Sub main wirings with PVC aluminum conductor cables in PVC/STEEL conduits / TW battens up to 2 runs of 6 Sq.mm removing materials from site, taken as credit , making good the disturbed surfaces all as specified and as directed.
S&F LED panel light 30/32 watt (2 x2 ),white powder coated CRCA full glow recess/surface mounting LED backlite panel, integrated electronic driver complete including connection from ceiling rose to light fitting with twin core cable 23/0.0076 Sqmm complete all as directed.
S&F ceiling fan complete with accessories 230 V,1400 mm sweep, BLDC type,BEE 5 star rated complete fixing arrangements complete all as specified and directed.
S&F LED building security light fitting 45 W made up of pressure die cast housing with toughened glass and individual high power LEDs with secondary optics, IP66 protection and impact resistance of IK07, complete pre-wired and connecting up with suitable twin core flexble copper wire including provision of necessary GI tubing medium grade 25mm bore of pipe 1.5 bent to shape with necessary clamps made out of mild steel, nuts and bolts etc., including two coats of synthetic enamel paint over a coat of red oxide primer on exposed steel surface for fixing the fitting to Buildings complete all as specified and as directed.
M&L for power / Sub-main wiring with PVC insulated unsheathed, FRLSH ,1100 volts, grade multistranded copper conductor, two runs of single core 6 sqmm conforming to IS-694, drawn through and including suitable dia rigid PVC conduit, conduit fittings and conduit accessories alongwith one run 6 sqmm PVC insulated single core multistranded copper conductor cable (green) as earth continuity conductor concealed in walls and fixed with suitable clamps on ceiling / roof trusses etc. and connecting to common earth dolly complete all as specified and as directed.
Taking down unserviceable Exhaust fan /Air circulator fans including sealing cable end, dismantling blades and removing fan and deposit to store complete all as specified and as directed.
Taking down unserviceable ceiling fan of any seep including sealing cable end, dismantling blades and removing fan and deposit to store complete all as specified and as directed.
S&F exhaust fans AC single phase 230/ 240 V of size 600 mm sweep, 900 RPM with louver complete all as specified
S&F exhaust fans AC single phase 230/ 240 V of size 450 mm sweep, 900 RPM with louver complete all as specified .
S&F exhaust fans AC single phase 230/ 240 V of size 300 mm sweep, 1425 RPM with louver complete all as specified .
S&F Air circulator fans AC single phase 230/ 240 V of size 600 mm sweep with fixing arrangement complete all as specified .
M&L for cutting and making hole to fix the exhaust fan of size 300 mm to 600 mm in existing brick / stone wall built in cement mortar of any description or making necessary alteration in the existing ventilators/ window of steel /wood/ aluminium frame work to fix the exhaust fan as per site requirement and making good the disturbed surface to match with existing complete all as specified and directed.
S&F earth continuity conductor or main earthing lead 4mm dia fixed to valve on batten or recess or chases or burried in ground or drawing in conduit or any other situation for loop earthing complete all as specified and directed
M&L for earthing complete with galvanised iron earth plate electrode 600mm X 600mm X 6mm thick, with and including earthing lead with GI wire of 4mm dia , protected with 15mm dia GI pipe light grade upto a length of 7.5m. The plate shall be buried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of the earth plate at a depth not less than 1.5 metres below ground level, connected to earth lead as described here-in-before by means of bolts, nuts, washers and checknuts made out of galvanised iron or mild steel, earthing lead protected by as described here-in-before and connected to main switch board or main control board or electric pole all as shown on electrical plate No.3 of MES Sch Part-I including necessary earth work and excavation in any type of soil, plain cement concrete 1:3:6, type C1 chamber, reinforced cement concrete cover slab 1:2:4 type B1, 50mm thick with 8mm dia TMT bars at 140mm centre to centre both ways and handle of 10mm dia MS round bars 450mm long, GI pipe of bore 20mm medium grade for watering with funnel, wiremesh, salt, charcoal, lugs including testing complete all as specified and as directed.
Supply, install,test and comissioning of Hi wall split units indoor and outdoor units complete with cordless remote control unit and with inbuilt air ioniser and Plasma filter for better Indoor air quality with minimum 5 Star rating and EER 3.2 (copper condenser coil) of capacity 2.0 TR Invertor type including GI powder coated brackets 16SWG for fixing of out door unit, grouting with suitable size fastners complete all as specified and as directed.
Supply, laying and testing XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm, 3.5 core complete all as specified
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm ,3.5 core complete all as specified
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm, 3.5 core complete all as specified
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out in any type of soil for laying cables / pipes / erection of poles etc complete all as specified .
moving excavated material (soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified .
Returning filling in soil including spreading leveling watering and well ramming in layers not exceeding 25 cm each complete all as specified .
M&L for fine seived excavated dry soil laid to the required width of trench at botom and top of cable as cushioning to cable complete all as specified . Note :- Thickness shall be measured after punning
Supply and laying of common burnt clay building bricks, sub class B size for cable protection all as specified
M&L for GI tubing 50mm dia , light grade for cable protection laid in trenches in road crossing or fixed to wall/Pole complete all as specified
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.52 MB
87766TENDER.pdf
Tender Documents • 1.43 MB
BOQ_829123.xls
BOQ • 0.65 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .