Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.3 LAccepted-AOC BUILDING NO FLAT NO 19 6TH CROSS ROAD SANJEEVINI NAGAR MUDALAPALYA BANGALORE 560072 | BANGALORE | BANGALORE | KARNATAKA | 560072 | ₹20.3 L Quoted ₹21.5 L | L1 | Accepted-AOC Being L1 Bidder |
| 2 | L2₹21.9 L+₹41,700 (1.94%)Rejected-AOC RZ 18 260 WEST SAGARPUR NEAR MCD SCHOOL NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | ₹21.9 L+₹41,700 (1.94%) | L2 | Rejected-AOC Not L1 Bidder |
| 3 | L3₹22.5 L+₹1.0 L (4.74%)Rejected-AOC 0001 000 KACHARI ROAD RAMAIPATTI MIRZAPUR UTTAR PRADESH 231001 | MIRZAPUR | UTTAR PRADESH | 231001 | ₹22.5 L+₹1.0 L (4.74%) | L3 | Rejected-AOC Not L1 Bidder |
| 4 | L4₹22.8 L+₹1.3 L (6.28%)Rejected-AOC | ₹22.8 L+₹1.3 L (6.28%) | L4 | Rejected-AOC Not L1 Bidder |
| 5 | L5₹24.9 L+₹3.4 L (15.8%)Rejected-AOC 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | ₹24.9 L+₹3.4 L (15.8%) | L5 | Rejected-AOC Not L1 Bidder |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
18 Oct 2023, 6:00 pmClosed
GE U WATER SUPPLY DELHI CANTT 10
GE U WATER SUPPLY DELHI CANTT 10
REPAIR MAINTENANCE OF INTERNAL WIRING ELECTRICAL FITTINGS LT PANELS EARTHING SYSTEM STREET LIGHTS ALONGWITH CONNECTED ELECTRICAL ITEMS FOR WATER SUPPLY INSTALLATIONS UNDER THE AOR OF AGE U WATER SUPPLY NO I UNDER GE U WATER SUPPLY DELHI CANTT 10
2023_MES_620824_1
GE/WS/IFA-47/Token-25 of 2023-24
Open Tender
Civil Works
Item Rate
180 days
GE U WATER SUPPLY DELHI CANTT 10
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
GE U WATER SUPPLY DELHI CANTT 10
₹70,000
Yes
10 Nov 2023
27 Sept 2023
20 Oct 2023
27 Sept 2023
18 Oct 2023
11 Oct 2023
Amount
Excavation in trenches not exc 1.5 metres wide and not exc1.5 metres deep for pipe line in any type soil, getting out and levelling of bottom surface to required level complete all as specified and directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc. 25 cm thick complete all as specified and directed.
Removal of excavated material from site to a distance not exceeding 50 meters away and depositing where directed at a level not exceeding 1.5 meters above the starting point
Excavation in trenches by cutting of road crossing, PCC hard standing for taking out/laying of pipe lines including PCC (1:2:4) type B-2 (with 40 mm graded aggregate) in foundations,filling and mass concrete complete including making good the existing surface complete all as specified and directed.
M&L for taking out old unserviceable LT cable of any size/make from trenches/wall/ducts/roof complete all as specified and directed.
Supply, laying, testing & commissioning LT XLPE insulated armoured (heavy duty) electric cable with stranded aluminium conductor 1100 volts grade (ISI marked) & laid in trenches/pipes or fixed on pole of the following sizes:-
16 Sqmm x 4 Core
25 Sqmm x 3.5 Core
35 Sqmm x 3.5 Core
50 Sqmm x 3.5 Core
70 Sqmm x 3.5 Core
Supply & spread unwashed dry river sand for sand cushioning and covering the under ground cable in trenches/ducts. (Note :- Punning thickness shall be measured.)
M&L for brick protection with sub Class`B` bricks old size laid dry, flat over cable perpendicular across the cable in trenches
S & F galvanised steel tubing medium grade 40mm bore (ISI marked) for protection of under ground cable on poles/walls under road crossing complete all as specified and directed.
M&L for taking out old and broken PCC pole of any size/height from the existing size by breaking the foundation and dismantlimg the cable connections complete all as specified and directed.
Excavating in post holes each not exceeding 0.5 cum in any type soil, getting out, returning filling in and ramming earth or broken rubble mixed with around earth in layers not exceeding 25 cm thick, watering and removing surplus soil to a distance not exceeding 50 metre and making good surface complete all as specified and directed.
Supply, erecting and fixing in position Steel tubelar swaged poles complete with cast iron base plate finial taper plug bolts, nuts & screws as specified type 410 SP-31 (9 Metres long) including necessary excavation as required.
Providing PCC (1:4:8) type D-2 using 40mm graded crushed stone aggregate as in foundations filling mass concrete bed of pipe etc complete all as specified and directed.
Provinding PCC (1:2:4) type B-1 using 20mm grded crushed sotne aggregate as in coping bed plate including weathering slightly rounded or chamfered angles and throating etc complete all as specified and directed.,
Supply and fixing in replacement 60 watt LED street light new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP-66 protection and impact resistance of IK07 including making connections with GI pipe 0.6 mtr angle bracket fixing on wall using suitable fastners and connectng to ceiling rose with appropriate copper wire complete all as specified and directed.
Supply and fixing in replacement 90 watt LED building security light new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP-66 protection and impact resistance of IK07 including making connections with GI pipe 0.6 mtr angle bracket fixing on wall using suitable fastners and connectng to ceiling rose with appropriate copper wire complete all as specified and directed.
Supply and fixing in replacement 120 watt LED flood light new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP-66 protection and impact resistance of IK07 including making connections with GI pipe 0.6 mtr angle bracket fixing on wall using suitable fastners and connectng to ceiling rose with appropriate copper wire complete all as specified and directed.
Supply and fixing poly carbonate junction box , weather and vermin proof of suitable size including provn of 2 Nos aluminium strip 25x3.15 mm size bus bar single phase and neutral suitabely mounted on bus bar insulators , including one No. MCB SP 6 Amps for light control,drilling of holes.Provn of suitable size of GI nuts, bolts, earthing bolt, double washer and galvanised flat iron clamps of suitable size for taking connections and fixing on LT steel tubular poles complete with locking arrangement complete including cable gland of suitable size at entry and exit point of cable. Note: i) Box shall be provided at 1 metre above the pedastal of pole. ii) Quoted rate shall be deemed to include bus bars, MCB and clamps.
M&L for carefully taking down old copper/aluminium point wiring (light, fan, bell,same board, independent or power) including complete fittings such as switches, ceiling roses, pendents, regulators, sockets etc and making good disturbed surfaces of wall, floor & ceiling etc.
M&L point wiring complete with 1.5 Sqmm single core multistranded copper conductor of 1100 volts grade PVC pre insulated FRLS and unsheathed cable enclosed in and including PVC casing and caping double locked box type with all PVC accessories such as Tee, bend, collar, elbow, square junction box etc fixed on the surface of wall/ceiling by means of PVCsleevel/dash fastners with cadmium plated screws including suitable size of PVC boards for mounting fittings like switches, sockets, fan regulator etc including 1.5 Sqmm insulated but unsheathed copper earth continuity conductor to common earth and connedcted to earth dolly for the following :-
One light point controlled by one, one way switch .
One Ceiling Fan/Exhaust fan point controlled by one, one way switch.
One 3 pin socket outlet 5 Amps on the same board with other switches.
One 3 pin socket outlet 5 Amps on the Independent board.
All as per item No- 2 here-in-before but with 2.5 Sq mm for 3 pin 15 Amps socket point controlled by one switch on independent board and 2.5 Sq mm copper conductor green in colour as earth continuity conductor connected to common earth dolly complete all as specified and as directed.
M&L for Switch piano flush type single pole, one way 5A.
M&L for Switch piano flush type single pole, one way 16 Amp
M&L for Socket outlet, 2 in 1, 3 pin 5A flush type
M&L for Socket outlet, 2 in 1, 5 pin 16A flush type
M&L for ceiling rose 3 terminal PVC/Polycarbonate isolated body complete all as specified and directed
M&L for decorative ultra slim round profile LED lightning fixture 20W,6000K, with extruded polycarbonate environmental friendly energy efficient incl taking down old unsv light fitting complete all as specified and directed
M&L for MCB Distribution 6 way, SPN, sheet steel, powder painted, with bus bar neutral link & earth bar etc. and fixing MCBs of various rating capacity complete all as specified and as directed.
All as per item no 28 here in before but MCB DB SPN 8 way
M&L for MCB TPN 63 Amps, 415 volts, 50 Hz suitable for fixing in MCB DB 'C' series including taking down old unsv MCB complete all as specified and as directed
M&L for MCB SPN 40 Amps, 415 volts, 50 Hz suitable for fixing in MCB DB 'C' series including taking down old unsv MCB complete all as specified and as directed.
M&L for MCB SP 6-32 Amps, 415 volts, 50 Hz suitable for fixing in MCB DB 'C' series including taking down old unsv MCB complete all as specified and as directed
Supply and fixing exhaust Fan, heavy Duty 450 mm sweep, 1400 RPM Single pole 230V , 50Hz complete all as specified and directed.
Supply and fixing ceilling fan 1200 mm sweep Single pole 230V , 50Hz complete with fan regulator and down rod connection complete all as specified and directed.
S&F in replacement new generation post-top Gate Light, energy saving, environment friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source 25W, 5700K complete with provision and fixing of GI pipe with necessary civil works involved complete all as specified and directed.
Supply and fixing LED Solar street light fitting 20 Watt including galvanized steel pole 6 meter height with in built lithium ion battery, solar panel, charge controller with dusk down sensor complete. (Excavation & earth work shall be measured separately)
Supply and fixing LED Panel light 36W environmental friendly energy efficient incl taking down old unsv light fitting complete all as specified and as directed.
M&L for earthing complete with galvanized steel earth plate electrode of size 600x600x6mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level connected to galvanised iron strip 25×4mm as earthing lead connectd by means of bolts, nuts, washers and check nuts all as shown in electrical plate No 3 of MES SSR Part-I, including testing on completion complete all as specified and as directed.
M&L for replacement to Off load Change over Switch of rating 200 Amp, 4-Pole 415V as per IS / IEC: 60947 - 1&3 with dual mounting facility fixed at exisiting/new location incl the connections complete all as specified and directed
M&L for replacement to Off load Change over Switch of rating 400 Amp, 4-Pole 415V as per IS / IEC: 60947 - 1&3 with dual mounting facility fixed at exisiting/new location incl the connections complete all as specified and directed
M&L for replacement to Bus Bar Chambers of rating 200 Amp, 4-Pole 415V 6 Way as per IS: 2675/1966 with mounting facility fixed at exisiting/new location incl the connections complete all as specified and directed.
M&L for replacement to Bus Bar Chambers of rating 400 Amp, 4-Pole 415V, 6 Way as per IS: 2675/1966 with mounting facility fixed at exisiting/new location incl the connections complete all as specified and directed.
Supply & fixing , install testing and commissioning of feeder pillar box ,outdoor type cubical shape,three phase, 4 wire, copper bus bar for phases and neutral made out of CRCA sheet 3.15 mm thick, factory fabricated, CPRI approved, powder coated, dust and vermin proof, provn for ventilation, angle iron frame and four legs of 50x50x6mm thick angle iron, 2 ft long grouted on PCC foundation of height not less than 30 cm from the ground level , grouting properly ,and of suitable size to accomodate the items mentioned below and having seperate compartment /chambers for cable gallery busbar ,switch gear etc all as specified and comprising of following including necessary cable connections to the MCCBs, voltmeter, Ammeter and cable lugs etc .
Copper bus bar with PVC sleeve rating 200 amps for Phase & 200 Amp for neutral - 01Set.
Phase indicating lamps LED type ( RYB) 01 Set
Incoming MCCB 125 Amp 3 pole 18 KA with adjustable thermal and fixed magnetic release -01 No
Outgoing MCCB 63 Amp 3-Pole 18 kA with adjustable thermal and fixed magnetic release - 01 Nos
FASD Stater ML-1.5 or MN-16 FASD-01 Nos
Analog time Switch -01 No
Single phase preventer-01 No
Supply & fixing of Nature Switch (using Infrared Sensor technology) based Automatic Street Light Control Panel designed for a total load of Single-phase 5-8 kW. Nature Switch operation should be based on Natural Light Lux* level. Required Illuminance Level for Switching ON is ≤ 60 Lux and for Switching OFF ≥ 10 Lux. The Sensor should also have part night operation facility of min. 4 hrs to max. 12 hrs. The Sensor along with Power Contactor of rating 40 Amps and Incoming-Outgoing MCBs of rating 40 Amps and should be enclosed in a pole/wall mountable Rust Proof, Electric Shock Proof, Termite proof and FR grade SMC Enclosure conforming to IP54. The circuit should also have provision for Manual Operation (i.e. Sensor By-Pass option) with control wiring of not less tha 10 Sqmm copper conductor with provision of mounting on suitable angle iron frame along with PCC foundation complete all as specified and directed by Engr-in-Charge.
Supply, Fixing and commissioning in replacement of existing butterfly valves with motorised butterfly valves rating PN-1.6 with IP-67 protection, 30-65 degree, 220V AC along with suitable control wiring of 5 Core x 1.5 Sqmm and 3 Core x 1.5 Sqmm for Panel and Valve respectively and suitable PLC panel complete with power contactor, Relay, Level controller and power supply of following sizes:
100 mm Dia
150 mm Dia
M&L for removing weeds and wild grass inside the installations using chemical spray and trimming trees and unwanted plants using petrol operated Tree/Grass cutting tools and dressing of the surface by scrapping high patches and filling low patches with the scrapping soil to give an even and neat look to the site and disposing off all the unwanted grass, bushes and debris all as directed by the Engineer-in-Charge.
M& L for Writing/Engraving of SM/MES No. of Different installed Plant/Pump Sets/ DG Set Machinery by engarving numbers on Brass/Aluminium plate properly afixed on the body of plant complete all as specified and directed by Engr-in-Charge.
Note:- Sch of credit amount of Rs.114476.00/- shall be deducted from total quoted BOQ Amount when work acceptance letter issued.
P S TRADERS
KUSHAL ENTERPRISES
Surjit and Sons
M P TYAGI ENGINEERS AND CONTRACTORS
Deven Associates
Ridhi engineers and builders
DHAIRYAE ENTERPRISES
MRITUNJYA ASSOCIATES
JS ENGINEERING ENTERPRISES
B.R. Enterprises
Yadav Enterprises
DS CONSTRUCTION
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .