Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.6 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹13.6 L+₹2.1 L (18.0%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹13.7 L+₹2.2 L (19.0%)Rejected-Finance DL 221 3 SALT LAKE SECTOR II KOLKATA 700091 WEST BENGAL | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | L3 | Rejected-Finance L3 | |
| 4 | L4₹14.1 L+₹2.6 L (22.3%)Rejected-Finance 119 MONOHAR PUKUR ROAD KOLKATA 700 026 | KOLKATA | KOLKATA | WEST BENGAL | 700026 | L4 | Rejected-Finance L4 | |
| 5 | L5₹14.5 L+₹2.9 L (25.5%)Rejected-Finance 3 C DR JAGABANDHU LANE KOLKATA 700012 | KOLKATA | KOLKATA | WEST BENGAL | 700012 | L5 | Rejected-Finance L5 |
Tender Value
Refer Docs
EMD Value
₹28,000
Closing Date
21 Feb 2022, 1:00 pmClosed
EXECUTIVE ENGINEER
O/o The EE_KNED, PWDte, P-5, CIT Road, 2nd Floor, Moulali, Kolkata-700 014.
Construction of Clinical cum Academic Building of WBUAFS at Belgachia, Kolkata---Additional Electrical Installation work.
2022_WBPWD_364313_1
WBPWD/EE/KNED/NIT-31 of 2021-22
Open Tender
ELECTRICAL WORKS ORG
Item Rate
21 days
WBUAFS, K B Sarani, Kol-37, Belgachia-reg.
Please refer Tender documents.
4 documents required · 4 mandatory
₹28,000
11 Mar 2022
3 Feb 2022
23 Feb 2022
4 Feb 2022
21 Feb 2022
7 Feb 2022
Amount
B) Out going having: 1. Supply & fixing 125A TPN SFU with 125A Fuse Link--------------5nos; Along with ON Indication lamp; 6A SP MCB as control circuit along with neutral link for each feeder/outgoing. 2. Supply & fixing 63A TPN SFU with 63A Fuse Link--------------1nos; Along with ON Indication lamp; 6A SP MCB as control circuit along with neutral link for each feeder/outgoing. 3. Supply & fixing 32A TPN SFU with 32A Fuse Link--------------1nos; Along with ON Indication lamp; 6A SP MCB as control circuit along with neutral link for each feeder/outgoing. C) Bus Section: 500 V 500 A. electrolyte grade Copper bus bar with vertical section of size 40x 10 mm for per Phase RYB, & 40x10 mm for neutral bars. Interconnection between main bus and outgoing switchgears should be done by Copper Bus Bar/ Equivalent ratting of Copper Wire. Bar for earth 25x6 Al. A bus bar shall be fixed with FRP chair & the entire bars are insulated with PVC heat Sinkable sleeve of suitable size & color as per direction of E.I.C.
Painting: Paint will be powder coated, After cleaning, the surface shall be given a phosphate coating, nine tank process system, SIEMENS GREY, RAL-7035 Shed Constructural Details: All incoming & outgoing panel mounted cubical Switch disconnector fuse shall be housed in Respective compartment with hinged & gasketted Door at front. All doors shall have Panel lock Arrangement. Degree of Protection will be IP-54 .The panel shall be properly Gasketted to prevent ingress of dust & moisture & Remain. Busbar will be properly arrange & all Switches shall be fixed by M.S. nuts & bolts On angle /flat iron frame base.as per direction of E.I.C. The PANEL will be fabricated by 14 SWG. CRCA Sheet. The sheet steel thickness will be 2mm & Gland plate shall be 2/3mm thick. Individual compartment door will be interlocked with respective breaker. Panel must have with Bus Alley and Cabe Alley with proper termination by 3/4 WAY Stud Type Power Terminal for every outgoing and incoming feeder. Individual nake plate should have on repective feeder.
Supplying and fixing 415V, 415A TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. Make: ( L&T / Havells / standard/SIEMENS)
Supplying and fixing double door 4 way Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. INCOMING- Supplying and fixing 415V 63A FP MCB Isolator on din rail of existing DBs and necessary connection. -1 No. OUTGOING-Supplying and fixing 240V 32A SP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection-12 Nos. Blank Plate- 0 nos. (Make: Legrand / L&T / Crabtree/SIEMENS)
Supply & Fixing of A.C timer Box in SS single door phosphatised powder coated 8 way SPN DB with neutral bar, din rail with IP-43 protection with electrical accessories & front door locking arrangement , earthing attachment on wall consisting of the following items including necessary interconnection by suitable size of 1.1KV. Grade standared PVC insulated Copper wire ( Fire Retarant) and suitable AUTO/ MANUAL arrangement. a) Single door (2+12) way SPN DB ----1no b) DIN mounted digital/analog time switch with daily & weekly programmable basis , min switching time 1 min, 25 ON/OFF programs,6 yrs. Battery backup, settable DST & key pad lock features. c) DIN Mounted 22ADP Power contractor MX.22 with 250V, magnetic coil with two pole having one NO & one NC contact, d) 32A SP MCB(10kA, C curve)—1no, MCB housing should be thermostat materials( fire retardant). e) One no. RED and one no. Green ,240V, LED indicator for indicating AUTO/ BYPASS indication---1 set ( Make: L & T/ ABB/ CRABTREE/ Havells)
Supplying & Fixing Industrial Plug & Socket board with 415 V, 30A, TPN & Earth Metal Industrial Plug socket & 30A Industrial top incl. S&F 32 A TPN/FP MCB breaking capcity 10kA (C- Curve) in SS enclosure fixed on wall and cecessary conection. (Make: Legrand / L&T / Crabtree/SIEMENS)
Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated including 32A DP MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment (Make: Legrand / L&T / Crabtree/SIEMENS)
Supply of 2 core 10sqmm of 1.1 KV grade alluminium XLPE, PVC/ armoured LT cable ( Make : Havells/ Polycab/ Finolex )
Supply of 4 core 16sqmm of 1.1 KV grade alluminium XLPE, PVC/ armoured LT cable ( Make : Havells/ Polycab/ Finolex ) (VTPN to PDB)
Supply of 4 core 70sqmm of 1.1 KV grade alluminium XLPE, PVC/ armoured LT cable ( Make : Havells/ Polycab/ Finolex )
Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting
Supplying of 40 mm dia HDPE PIPES pe 63, 4kgf/cm2 Make-supreme, type-SDR-21, (Make- Supreme/Hensel/ Harse or similar make)
Excavation of soil for cable laying filling & ramming. (0.150x0.450x25x04 (WxDxLength xNo. of pole)
Laying only Cable upto 50 sqmm through existing RCC/Hume/ GI Pipe/open masonary trench for single, 2, 3, 3½ & 4 core
Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish. From 2.5 sqmm to 35 sqmm at an average depth of 75 mm in floor/pavement/wall etc.
Laying 2 Core 10 sqmm XLPE Al. armoured cables with supplying & Fixing pole clamp, tanis screw, bobin insulator, 4"X1/2" nut bolt washer ring insulator for holding 2 core 10 armoured & 7/14 standed G.I. wire, 9 S.W.G. Al binding wire.
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required
3 x 22/0.3 (1.5 sqmm)
2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC
2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC
4x126/0.4 (16 sqmm) + 2x80/0.4 (10 sqmm) as ECC
4x 25 sqmm + 1x 10 sqmm as ECC
4x 50 sqmm + 1x 16 sqmm as ECC
Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works
20mm size
25mm size
40mm size
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision/Polycab/AKG make) incl. necy. fittings as required
2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC
2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below
4 core 16sqmm
2 core 10sqmm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials
4 core 16sqmm
2 core 10sqmm
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate and 2 no. suitable size “Ph & N” copper bar & earthing attachment fixed on wall incl. mending good damages to original finish. Average run 9 mtr
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 6A 3 pin Modular type plug socket & switch (Brand approved by EIC) on 4 Module GI switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works. On Board
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 25A Modular type socket, 25 A, Modular type AC starter (Brand approved by EIC) with 25A Modular switch type DP MCB (C-Curve) and 6 Module GI Modular type switch board with 6 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing of 20/25A plug top for AC machines
Supply of 250V. 50 Hz. 400 mm. Sweep Wall Fan oscillating type on wall with all parts. (Make : Havells / Orient / Usha)
Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length
Supply of single LED light fitting with S & F 1 no. 18W LED tube with Alluminium Heat Sink body including inbuild driver and complete accessories ( Make : Philips / Crompton / Havells)
Supply of twin LED light fitting with S & F 2 no. 18W LED tube with Alluminium Heat Sink body including inbuild driver and complete accessories ( Make : Philips / Crompton / Havells)
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
Supply and Fixing single LED light fitting with S & F 1 no. 18W LED lamp with Fixing only pendent light fitting complete with lamp, shade and 24/0.2 mm (1.5 sqmm) flexible copper wire incl. S&F pendent holder ( Make : Philips / Crompton / Havells )
Supply of 10W LED Bulkhead LED and Fixing bulk head ceiling fitting on wall /ceiling by screws etc. ( Make : Crompton/ Philips / Havells/ Bajaj )
Supply of 72W LED Fittings having Aerodynamically designed street light with excellent thermal management, inbuilt tilt angle arrangement with IP66 protection. ( Make : Crompton,LSTP-72-CDL / or similar of Philips / Surya / Bajaj / Jaquar / or similar)
S&F of 80mm dia 2 Mtrs long G.I pipe Minipole with sole plate incl. S&F 40mm dia 1.5 Mtrs pole bracket incl.providing CC (6:3:1) base block (around the pole) dimension 0.60x0.60x0.76 mt. above ground level, neatly cemented finish (3 mmthick), at the base pole (in lieu of CC muffing) incl. drilled hole in pole suitable for alkathene/polythene pipe entry incl. earthing attachment.
S&F of 80mm dia 9 Mtrs long G.I pipe Minipole with sole plate incl. S&F 40mm dia 1.5 Mtrs pole bracket incl.providing CC (6:3:1) base block (around the pole) dimension 0.60x0.60x0.76 mt. above ground level, neatly cemented finish (3 mmthick), at the base pole (in lieu of CC muffing) incl. drilled hole in pole suitable for alkathene/polythene pipe entry incl. earthing attachment.
S&F cylindrical type pole head suitable for 100 mm. dia seamless pipe and should be waterproof & fabricated from steel member steel pipe. The cylindrical portion of the pole head which sleeve over the pole shall have a length of 40 cm. ( 18" ) approx. Incl. making 225 mm. dia ( 9" ) cable terminal box.
Supply and fixing of Junction Box Syntex make with front side opening door and locking arrangement, with clamp. Junction box having 140x140x95mm dimension. Each have consist of the following materials EARTH Stud, 2 WAY Stud Type Power Terminal – 32A, 2A Fuse link with base (L&T/ Havells)- 1no, Make- Syntex, Type No- GSJB-1414 (Make- Syntex/ Hensel/ or similar make)
Painting of Steel Tubular Pole of lengths and no. of coats of paint, as given below with ready mixed paint/primer of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint Upto 9.0 mtr. long pole
One coat of red lead/Zinc chromate priming.
1st coat of synthetic enamel paint over the primer.
2nd coat of synthetic enamel paint over the 1st coat.
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By TATA-Medium GI pipe
Excavation of soil for installation of Earth Electrode and filling & ramming. For Soft Soil.
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required.
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages 4 SWG.
Messrs HI- Q - ENTERPRISE
SILICON SOFTWARE
UNITED CONSTRUCTION SERVICE
S. A. ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .