Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.7 LAccepted-AOC | L1 | Accepted-AOC Accepted. Being the L1 bidder. | |
| 2 | L2₹26.1 L+₹39,872 (1.55%)Rejected-AOC 301 CHAMUNDA ENCLAVE PLOT NO 89 AIROLI SECTOR 8A NAVI MUMBAI 400 708 | THANE | MAHARASHTRA | 400708 | L2 | Rejected-AOC Rejected as not being the lowest bidder. | |
| 3 | L3₹31.1 L+₹5.4 L (21.1%)Rejected-AOC FLAT NO 301 PEARL APARTMENT PLOT NO 121 SECTOR 8A AIROLI NAVI MUMBAI 400708 | NAVI MUMBAI | THANE | MAHARASHTRA | 400708 | L3 | Rejected-AOC Rejected as not being the lowest bidder. | |
| 4 | L4₹34.5 L+₹8.8 L (34.3%)Rejected-AOC UNIT NO 7 MOUNT VIEW CO OP HOUSING SOCIETY LIMITED MUMBAI MANKHURD 400 088 | MUMBAI SUBURBAN | MAHARASHTRA | 400088 | L4 | Rejected-AOC Rejected as not being the lowest bidder. | |
| 5 | L5₹36.6 L+₹10.9 L (42.6%)Rejected-AOC 0 0 BASANT AVENUE PHASE II PUNJAB GURDASPUR PUNJAB 143505 | GURDASPUR | PUNJAB | 143505 | L5 | Rejected-AOC Rejected as not being the lowest bidder. |
| Sl No | Description | Qty | Unit | M/s Qureshi Construction Co L1 | R J ENTERPRISES L3 | Joy builders L4 | VIJAY ENTERPRISES L5 | S K ENTERPRISES L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down cement mortar or lime plaster of any description from stone or brick wall etc including raking out joints, hacking for key scrubbing down with water and disposing off the rubbish materials out side MD and including necessary scaffoldings complete all as specified and directed. | 1,200 | Sqm | 10 ₹12,000 Lowest | 32 ₹38,400 | 10 ₹12,000 Lowest | 20 ₹24,000 | 18 ₹21,600 |
| 2.00 | M & L for Rendering 15mm thick in (1:6) CM on fair faces of brick work or concrete surfaces of walls and finishing even and smooth without using extra cement complete all as specified and directed. | 350 | Sqm | 100 ₹35,000 Lowest | 250 ₹87,500 | 200 ₹70,000 | 300 ₹1,05,000 | 270 ₹94,500 |
| 3.00 | M&L for rendering 5 mm thick in CM 1:3 as in ceiling finishing even and smooth (with out using extra cement) etc complete all as specified and directed. | 400 | Sqm | 80 ₹32,000 Lowest | 180 ₹72,000 | 190 ₹76,000 | 220 ₹88,000 | 144 ₹57,600 |
| 4.00 | M&L for Rendering 20mm thick in (1:4) CM (in two coats (15+5mm) with both coats mixed with liquid water proofing compound, surface finished even and fair without using extra cement complete all as specified and directed. ( Note : WPC will be measured separately). | 600 | Sqm | 200 ₹1,20,000 | 310 ₹1,86,000 | 220 ₹1,32,000 | 350 ₹2,10,000 | 180 ₹1,08,000 Lowest |
| 5.00 | Supply only integral water proofing compound. | 167 | Kg | 40 ₹6,680 | 32 ₹5,344 Lowest | 100 ₹16,700 | 70 ₹11,690 | 60 ₹10,020 |
| 6.00 | M&L for preparation of new plastered surfaces of walls, chajjas, slab projections and applying two coats of 100% Anti fungal acrylic emulsion paint in approved shade over a coat of primer and including necessary scaffolding complete all as specified and as directed. | 600 | Sqm | 40 ₹24,000 Lowest | 90 ₹54,000 | 80 ₹48,000 | 100 ₹60,000 | 63 ₹37,800 |
| 7.00 | M&L for preparation of new plastered surfaces and applying three coats of white wash on ceiling etc complete all as specified and directed | 400 | Sqm | 10 ₹4,000 Lowest | 12 ₹4,800 | 20 ₹8,000 | 12 ₹4,800 | 45 ₹18,000 |
| 8.00 | M&L for preparation of new plastered surfaces of walls and applying two coats of distemper oil emulsion over a coat of alkali resistant primer using roller etc complete all as specified and directed. | 350 | Sqm | 40 ₹14,000 Lowest | 45 ₹15,750 | 81 ₹28,350 | 70 ₹24,500 | 63 ₹22,050 |
| 9.00 | M&L for preparation of old surfaces of walls/ceiling including brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salt and trading oil and greasy spots, washing down with water, filling of cracks with Dr fixit crack filler or equivalent make and applying one coat of 100% antifungal weather resitant exterior acrylic paint over one coat of primer of same approved shade including necessary scaffolding work etc complete all as specified and directed. | 3,300 | Sqm | 30 ₹99,000 Lowest | 150 ₹4,95,000 | 60 ₹1,98,000 | 75 ₹2,47,500 | 45 ₹1,48,500 |
| 10.00 | M&L for special treatment for sunken portion of WCs/ Bath & toilet executed in following stages:-
Stage 1 :- Demolition of WC including lime concrete and cement concrete coba etc and preparing the surfaces of existing sunken portion of WCs or bath etc with wire brush to remove all loose dirt, oil grease etc including removing debris outside MD land etc Complete.
Stage 2:- Providing 10mm thick plaster in CM 1:3 mixed with integral water proofing chemical of approved make in the proportion/quantity all as per Manufacture's instructions.
Stage 3:- Apply Dr Fixit Primeseal primer or Equivalent of STP Ltd (and allow to dry for 8 hours) all as per Manufacture's instructions.
Stage 4:- Apply two coats of water proofing elastomeric coating system of Dr Fixit Raincoats with DFT 100 Micron or shalicry 215 of STP (The surface after painting one coats shall be allowed to dry of 6 hours before next coats) all as per Manufacturer's instructions.
Stage 5:- Rendering 10mm thick in CM 1:3 mixed with Integral water proofing chemical Dr Fixit Pidicrete URP or plaster seal of STP Ltd all as per Manufacture's instructions.
Stage 6. All CI joints shall filled with mixture of cement fine sand and plaster seal of STP Ltd or Dr Fixit pidicrete URP all as per Manufacture's instruction.
Stage 7:- Making holes in wall and fixing 600mm long 40mm dia medium grade GI spout for draining the surplus water if any
Stage 8:- Carry out ponding test for 48 hours to ensure water tightness of repaired sunken portion.water tightness of repaired sunken portion and filling of sunken portion for cement concrete Type E2 1:5:10 using 40 mm graded aggregate as in lean concrete complete all as specified and directed. Note :- (a) Only plan area shall be measured and accorded for payment under this item. (b) Depth of sunken portion of WC's/Baths shall be upto 35cm, which is to be taken into account while quoting the rate against this item. (c) Rate quoted by Contractor shall be deemed to be included for all the horizontal and verticale treated surfaces of sunken portions of WC & Bath. | 10 | Sqm | 2,000 ₹20,000 | 600 ₹6,000 | 500 ₹5,000 Lowest | 4,000 ₹40,000 | 1,800 ₹18,000 |
Tender Value
₹44.5 L
EMD Value
₹89,000
Closing Date
21 Jun 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(NW) BHANDUP
GE(NW) BHANDUP, MUMBAI
COMPREHENSIVE MAINTANENCE OF BUILDINGS AT MO (MB) GHATKOPAR UNDER GE NW (BHANDUP)
2024_MES_648759_1
8327/B
Open Tender
Civil Works
Item Rate
270 days
GHATKOPAR
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE(NW) BHANDUP
₹89,000
Yes
11 Sept 2025
1 Apr 2024
22 Jun 2024
1 Apr 2024
21 Jun 2024
7 Jun 2024
1 Apr 2024 - 10 Apr 2024
Amount
Taking down cement mortar or lime plaster of any description from stone or brick wall etc including raking out joints, hacking for key scrubbing down with water and disposing off the rubbish materials out side MD and including necessary scaffoldings complete all as specified and directed.
M & L for Rendering 15mm thick in (1:6) CM on fair faces of brick work or concrete surfaces of walls and finishing even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 5 mm thick in CM 1:3 as in ceiling finishing even and smooth (with out using extra cement) etc complete all as specified and directed.
M&L for Rendering 20mm thick in (1:4) CM (in two coats (15+5mm) with both coats mixed with liquid water proofing compound, surface finished even and fair without using extra cement complete all as specified and directed. ( Note : WPC will be measured separately).
Supply only integral water proofing compound.
M&L for preparation of new plastered surfaces of walls, chajjas, slab projections and applying two coats of 100% Anti fungal acrylic emulsion paint in approved shade over a coat of primer and including necessary scaffolding complete all as specified and as directed.
M&L for preparation of new plastered surfaces and applying three coats of white wash on ceiling etc complete all as specified and directed
M&L for preparation of new plastered surfaces of walls and applying two coats of distemper oil emulsion over a coat of alkali resistant primer using roller etc complete all as specified and directed.
M&L for preparation of old surfaces of walls/ceiling including brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salt and trading oil and greasy spots, washing down with water, filling of cracks with Dr fixit crack filler or equivalent make and applying one coat of 100% antifungal weather resitant exterior acrylic paint over one coat of primer of same approved shade including necessary scaffolding work etc complete all as specified and directed.
M&L for special treatment for sunken portion of WCs/ Bath & toilet executed in following stages:- Stage 1 :- Demolition of WC including lime concrete and cement concrete coba etc and preparing the surfaces of existing sunken portion of WCs or bath etc with wire brush to remove all loose dirt, oil grease etc including removing debris outside MD land etc Complete. Stage 2:- Providing 10mm thick plaster in CM 1:3 mixed with integral water proofing chemical of approved make in the proportion/quantity all as per Manufacture's instructions. Stage 3:- Apply Dr Fixit Primeseal primer or Equivalent of STP Ltd (and allow to dry for 8 hours) all as per Manufacture's instructions. Stage 4:- Apply two coats of water proofing elastomeric coating system of Dr Fixit Raincoats with DFT 100 Micron or shalicry 215 of STP (The surface after painting one coats shall be allowed to dry of 6 hours before next coats) all as per Manufacturer's instructions. Stage 5:- Rendering 10mm thick in CM 1:3 mixed with Integral water proofing chemical Dr Fixit Pidicrete URP or plaster seal of STP Ltd all as per Manufacture's instructions. Stage 6. All CI joints shall filled with mixture of cement fine sand and plaster seal of STP Ltd or Dr Fixit pidicrete URP all as per Manufacture's instruction. Stage 7:- Making holes in wall and fixing 600mm long 40mm dia medium grade GI spout for draining the surplus water if any Stage 8:- Carry out ponding test for 48 hours to ensure water tightness of repaired sunken portion.water tightness of repaired sunken portion and filling of sunken portion for cement concrete Type E2 1:5:10 using 40 mm graded aggregate as in lean concrete complete all as specified and directed. Note :- (a) Only plan area shall be measured and accorded for payment under this item. (b) Depth of sunken portion of WC's/Baths shall be upto 35cm, which is to be taken into account while quoting the rate against this item. (c) Rate quoted by Contractor shall be deemed to be included for all the horizontal and verticale treated surfaces of sunken portions of WC & Bath.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises etc out side MD land complete all as specified and directed.
Resecuring or easing & adjusting without taking down door shutter of any description exc 1.00 but n exc 2.00 Sqm each complete all as specified and directed.
M&L for Non-skid ceramic tiles (Coloured) 7 to 8mm thick rectangular area of each tiles exc 0.06 sqm n exc 0.11 sqm in floors etc,.set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1:4 laying floor finished complete all as specified and directed.
M&L for glazed ceramic coloured tiles 300x200mmx7mm thick in vertical surfaces such as skirting/dado and risers to steps and including over 10mm thick rendering in CM 1:3 on fair faces of brick/concrete surfaces as in backing coat for tiles. etc, all as specified and directed.
M &L for Non-skid ceramic tiles (Coloured) 7 to 8mm thick rectangular area of each tiles exc 0.18 sqm n exc 0.36 sqm in floors etc,.set and jointed in neat cement slurry and pointed in white or coloured cement to match, including 15mm thick screed bed in CM 1:6 laying floor finishesed complete all as specified and directed.
M&L for Non-skid ceramic tiles (Coloured) 7 to 8mm thick rectangular area of each tiles exc 0.18 sqm n exc 0.36 sqm in vertical surface etc,.set and jointed in neat cement slurry and pointed in white or coloured cement to match including over 10mm thick rendering in CM 1:4 on fair faces of brick/concrete surfaces as in backing coat for tiles complete all as specified and directed.
Dismantling asbestos cement (corrugated semicorrugated, etc) sheets in roof covering including ridge, north light curves etc complete all as specified and directed.
Dismantling wrought iron or mild steel work of vallay gutter and expended metal any description not other wise provided for complete all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fitting and accessories) complete all as specified and directed.
M&L for 6mm thick asbestos cement corrugated or semi-corrugated sheet fixed with l-type or j-type or cranked hook bolts in roof,walls etc complete all as specified and directed.
All as per item No.20 above but except sheets complete all as specified and directed.
S&F 1mm thick GI sheeting in ridges hips, valley gutters, drip etc necessary dismantling of AC sheets and refixing the same position complete all as specified and directed.
S&F 0.80 mm plain galvanised Mild steel sheeting in ridge, hips, valley gutter,drip and straight flashing class8 with zink coating @ 120 gms /sqm fixed with L- type or J- type or cranked hooks bolts complete all as specified and directed.
S&F 160mm bore PVC rain water pipe single socketed(ISI Marked) any length with rubber ring joints , complete fittings etc fixed to wall fixed with MS clamps 8mm dia with two nuts wall nails etc complete all as specifed and directed.
S&F Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary,gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 complete all as specified and directed.
S&F Mild steel work of Framed work such as for portions framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 including welding complete all as specified and directed.
S&F Expanded metal, cut to length, bent to shape required (weight per sqm exc 4kg) and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members complete all as specified and directed.
Dismantling of ceiling boards (fibre,pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets etc complete all as specified and directed.
S&F Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Alumi nium framework with screws complete all as specified and directed.
S&F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed.
S&F aluminium anodised snap grid frame work of size 605 x 605mm complete all as specified and directed.
M&L for Removal of plant growth by injection with chemical glyphospate solution ( 4 % conceneration ) @ 20ml or till refuse by cutting or injection in stem of plants or roots at 30mm. The area shall then be sprayed with solution 25ml glyphosphate ( 4% concent) dulited with 1 ltr of water. All roots / plants shall be removed completely and making good the distrubed surface and painted with cement base or acrylic paint complete all as specified and directed.
M&L Rotational moulded polyethylene water storage tanks (Cylindrical verticval with closed top) hoisted & fixed in position in repairs of 1000 ltrs capacity complete all as specified and directed.
M&L in repairs Ball valve high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed complete 25mm dia complete all as specified and directed.
M&L Nipple suitable for HDPE water tank (minimum weight 25mm - 65 gms) 25mm bore dia complete all as specified and directed.
S&F in repairs CP bib tap 15mm bore fancy type with crutch or butterfly handle, screwed for iron pipe or for unions and fixed complete all as specified and directed.
S & F Brass CP health faucet with 8mm Dia 1.0 Meter Long Flexible Tube and Wall Hook screwecd for iron pipe fancy type long body complete all as specified and directed.
Supply and fix in repair 10 ltr, PVC, valveless, syphonic action type, flushing cistern, low level/ high level including inlet, ball valve, float and handle including brackets with and including PVC flush pipe 32 mm bore, connecting to WC etc complete all as specified and directed.
S&Fin repair wash down water closet (pedestal pattern) white and including plastic water closet seat cover as per reqd colour with flat bottom and seat cover and mild steel chromium plated or aluminium hinging device (excluding flushing cistern ) etc complete all as specified and directed.
Demolition of concrete in ground floors (un re-inforced) and paving n.exc. 15 cm thickness (below or above ground level) and removal of rubbish/ demolished materials out of MD land complete all as specified and directed.
M&L for 100mm thick cement concrete type B-1 1:2:4 using 20mm graded stone aggregate in flooring finishes the surfaces even and smooth without using extra cement etc complete all as pecified and directed.
Chipping, removing carefully loose/damaged concrete including plastering from surfaces of RCC members, in any location by low impact Hammer/Breakar without damaging the structure & cleaning the surfaces with wire brush etc and disposal of debris out side MOD land complete all as specified and directed. Note : 1) Hard concrete shall not be removed by force
M&L for cleaning existing reinforcement with wire/ rotary wire brush to a shining bright finish, making the surfaces free from loose material, dirt etc complete and applying two coats of alkaline rust converting primer conforming to ASTM-B-117 of approved make on rebars with time interval of 1 hour between the coats, complete all as specified and directed. (Note :- Mode of measurement: superficial area of concrete will be measured.)
M&L for carry out application of ‘Bi-polar migratory corrosion inhibitor of approved make on RCC surfaces, complete all as specified and directed. (Note :- Mode of measurement: superficial area of concrete will be measured.)
M&L for Anticorrosive Treatment to Reinforcement using IPNET-RB of approved make by application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat. The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces complete all as specified and directed . Note :- Mode of measurement: superficial area of concrete will be measured.
M&L for Epoxy bond coat of approved make over exposed concrete surfaces prior to application of any type of mortar / concrete to ensure bond between old concrete & new concrete/ new mortar by brush application, complete all as specified and directed.
M&L for providing Polymer Bonding Agent of approved make followed by flexible polymer based putty ( 1cement: 1.2 finesand :20% polymer by weight of cement : water as required ) on cracks after cutting the cracks to a 'V' shaped groove upto 10 mm wide and 10 mm deep in structural RCC members , finished with spatula etc. complete all as specified and directed.
M&L for building up the profile of structural members using polymer modified mortar of approved make while the bonding agent is still tacking upto 20mm thickness, including levelling, profiling etc, complete all as specified and directed.
M&L for building up the profile of structural members using polymer modified mortar of approved make exceeding 20mm thick and not exceeding 40mm thick in two layers, each of equal thickness including levelling, profilling etc, complete all as specified and directed.
M & L for applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer including preparation of new steel surface of any discription not otherwise discribed over 10 cm width or girth, complete all as specified and directed.
Routine maitenance of sliding door shutter of following sizes the maintenance including the following complete all as specified and directed. (a) Dismantling of MS works of any description such as rollers pulleys, guides, bottom sliding tracks and corrugated sheets including necessary straightening of bends. (b) Refixing the serviceable accessories such as rollers, pulleys, guides, channels bottom sliding tracks corrugated sheets etc. (c) Replacement of unserviceable accessories such as rollers, pulleys, guides, channels bottom sliding tracks corrugated sheets etc. (d) Cleaning, oiling, greasing etc complete of all movable parts all as required at site( Note- The parts and accessories to be replaced shall be measured and paid seperetely ) (A) Area of shutter n.exc 5.00 sqm of each leaf
All as per item No.52 above but for Area of shutter exc 5.00 sqm but n. exc 10.00 sqm of each leaf
All as per item No.52 above but for Area of shutter exc 10.00 sqm but n. exc 20.00 sqm of each leaf
Routine maitenance of rolling shutter of following sizes the maintenance including the following all as specified and directed. (a) Taking down hood covers for carrying out routine maintenance and refixing. (b) Dismantling the MS and CI works of any description such as sheets, shafts, cost iron wheels lath etc and taking down helical springs, rollers and other accessories etc. (c) Refixing the unserviceable accessories such as shafts, helical springs, rollers lath sheets, cast iron wheels etc. (d) Replacement of the unserviceable accessories such as shaft helical spring, rollers, MS lsth sheets hood covers, cast iron wheels including drilling, welding etc complete. (e) Cleaning, oiling, greasing etc complete of all movable parts all as required at site( Note- The parts and accessories to be replaced shall be measured and paid seperetely ) A) Area of shutter n.exc 5.00 sqm maximum size 1.80mx2.40m
All as per item No.55 above but for area of shutter exc 5.00 sqm but n.exc 10.00 sqm (maximum size 3.20m in height)
All as per item No.55 but for Area of shutter exc 10.00 sqm but n.exc 20.00 sqm (maximum size 5.15m in height)
All as per item No.55 but for Area of shutter exc 20.00 sqm but n.exc 40.00 sqm (maximum size 6.77m)
Supply only mild steel lock plate 150mm width 3.15mm thickness reinforced with MS angle of 35x35x5 mm at bottom including pulling handle sliding bolt etc complete all as specified and directed.
Supply only mild steel gear box including gear wheels of rolling shutter machine cut with MS shaft 25mm bore heavy grade complete all as specified and dircted.
Supply only MS roller of 50mm to 60mm dia including nuts bolts etc all as specified and directed.
Supply only MS roller of 65 mm to 75mm dia including nuts bolts etc all as specified and directed.
Supply only MS accessories for rolling shutter repair such as shaft helical prings , pully ,lath sheets ,cast iron wheels etc as specification and directed .
M&L for preparation of old surfaces of walls including washing, rubbing down and stopping of distempered and painted surfaces of wall and applying one coat oil bound distemper with roller complete all as specified and directed.
Supply only pillar tap cast copper alloy chromium plated fancy type complete all as specified and directed.
M & L for preparation of old steel surfaces of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
M&L for complete removal of existing treatment on ceiling and applying two coat of white wash on ceiling complete all as specified and directed.
M & L for cutting out cracks (not exc 5mm) to V-section in existing wall/chajjas and cleaning out and filling up with Dr fixit crack seal including necessary scaffoldings complete all as specified and as directed.
S&F for Pre- Painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering/ cladding to wall, fixed with self tapping ,drilling of screws/suitable length GI 'J' or 'L' hooks in roof complete all as specified and directed.
S&F for Pre- Painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/rigdes, fixed with self tapping ,drilling of screws/suitable length GI 'J' or 'L' hooks in roof, including necessary scaffolding etc complete all as specified and directed.
Demolition of brick work or stone boulder masonry,built in cement mortar or cement lime mortar including all quoins, arches, pillars etc, but excluding ashlar facings, dressed stone work and precast concrete articles and removal of rubbish/ demolished materials out of MD land complete all as specified and directed.
M&L for brick work with sub class B bricks straight or curved on plan exceeding 6 m mean radius built in CM 1:6 complete all as specifed and directed.
S&F PVC floor trap 100mm dia outlet, with CP grating including jointing to waste pipe, fixed in cement concrete type B1 (1:2:4) & including taking down old trap complete all as specified and as directed.
Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 15mm complete all as specified and directed.
Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 25mm complete all as specified and directed.
S&F CPVC pipe 150 mm bore SDR 11and plain CPVC SDR 11 fittings fixed complete to walls, ceilings or in floors etc, complete all as specified and directed.
All as per item No 76 above but 20 mm bore etc, complete all as specified and directed.
Cutting and grooving of wall for fixing of pipe lines and after fixing of GI pipe line and making good of all cutting surfaces complete all as specified and directed.
S&F Plates (plain or chequered) channels of Fe 410 W Gde-250 quality A square cut or notched (ordinary and counter sunk) forming holes, without any attachment fixed to sliding shutter/gates any other structural material complete all as specified and directed.
Taking down carefully copper/aluminum point wiring of any type such as concealed/surface/batten/casing and capping (light fan, socket or power) complete including fitting such as switches, ceiling roses, pendants, lamp/bracket holders, sketch/bulk head fittings, regulators, sockets, board outlets etc and making good the disturbed surfaces of walls, floor, ceiling etc for rewiring and repairs etc complete all as specified and directed.
Taking down main switches DBs with sheet metal enclosure 8/12 way SPN/DBs etc complete all as specified and directed.
M&L for point wiring light point/Ceiling/Exhaust fan point/ bell point with single core PVC insulated unsheathed 1100 volts grade FRLS cable with multi stranded copper conductor of size 1.5 Sqmm (nominal area) drawn through in and including stove enamelled steel conduit ISI marked not less than 20/25 mm dia surface on wall,ceiling with GI saddles, GI screws rawl plug (surface conduit wiring) with all fittings including tee,junction boxes PVC connector and provision of modular pressed steel terminal box of suitable size with inner and outer plates of mounting switch socket and regulators and drawing continuous earth wire of FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 1.5 Sqmm (nominal area) complete all as specified and directed. Note: colour coding should be maintained (PH:Red Neutral:Black, Half:Yellow Earth:Green)
All as per item No 82 above but one 5 Amps switch socket on same board complete all as specified and directed.
All as per item No 82 above but one 5 Amps switch socket on indipendent board complete all as specified and directed.
All as per item No 82 above but for 3 pin socket outlet 15 Amps independent with cable 2.5 sqmm unsheathed stranded 1100 volts grade complete with 2.5 sqmm PVC insulated earth wire and connecting to earth dolly complete all as specified and directed.
M&L for point wiring light point/Ceiling/Exhaust fan point/ bell point with single core PVC insulated unsheathed 1100 volts grade FRLS cable with multi stranded copper conductor of size 1.5 Sqmm (nominal area) drawn through in and including non metallic PVC casing caping ISI marked not less than 20/25 mm dia surface on wall,ceiling with all fittings including tee,junction boxes PVC connector and provision of Modular steel terminal box of suitable size with inner and outer platesmounting of switch socket and regulators and drawing continuous earth wire of FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 1.5 Sqmm (nominal area) complete all as specified Note: colour coding should be maintained (PH:Red Neutral:Black, Half:Yellow Earth:Green)
All as per item No 86 above but one 5 Amps switch socket combination on independent board complete all as specified and directed.
All as per item No 86 above but one 5 Amps switch socket combination on same board complete all as specified and directed.
All as per item No 86 above but for 3 pin socket outlet 15 Amps independent with cable 2.5 sqmm unsheathed stranded 1100 volts grade complete with 2.5 sqmm PVC insulated earth wire and connecting to earth dolly complete all as specified and directed.
Material and labour in repairs for point wiring complete with 4 sqmm PVC insulated unsheathed 1100 volts grade cable stranded copper conductor single core drawn through and including surfaced on rigid PVC conduit and conduit accessories of 20/25 mm complete with modular steel terminal box concealed in wall with inner and outer plates for fitting/ mounting switch/ sockets regulators etc with laminated sheet 3 mm thick cover and with 4 sqmm PVC insulated copper conductor earth wire and connected to earth dolly for one15 Amp socket point for connecting water coolers/ AC complete all as specified and directed.
Supply and fix in repairs switch modular type 6 Amp one way, 1 module complete all as specified and directed.
Supply and fix in repairs switch modular type 16 Amp one way, 1 module complete all as specified and directed.
Supply and fix in repairs socket modular type 2/3 pin combined 6 Amp 2 module type complete all as specified and directed.
Supply and fix in repairs socket modular type 3 pin combined 6/16 Amp 2 module type complete all as specified and directed.
Supply and fixing in repairs ceiling fan modular regulator stepped type 120 watts AC 230 V 2 module type complete all as specified and directed.
Supply and fix in repairs ceiling rose surface backelite three terminal complete all as specified and directed.
Supply and fixing modular metal flush box 3 with cover plate module complete all as specified and directed.
Supply and fixing modular metal flush box 6 with cover plate module complete all as specified and directed.
Supply and fixing modular metal flush box 8 with cover plate module complete all as specified and directed.
Supply & Fixing LED Light fitting 18/20 watt 220 V AC Decorative Box type with driver holder including ted complete with housing and LED 18 watt with aluminium heat sink on back of led rod,PF>0.90, LED light luminous efficiency shall not be less than 90 Lumens/Watt and the colour rendering index shall not be less than 70 and Correlated Colour Temperature is 6500K and light should complying ISI and BIS marking,having inbuilt surge protection device for overvoltage protection with all accessories prewired and making connection with 3 core copper flexible cable of size 23/.0076 from ceiling rose/PVC connector to light fitting and shall be fitted on new plastic square/round block complete all as per specified and directed.
Supply & Fixing LED Light fitting 10 watt 220 V AC Decorative Box type with driver holder including ted complete with housing and LED 10 watt with aluminium heat sink on back of led rod,PF>0.90, LED light luminous efficiency shall not be less than 90 Lumens/Watt and the colour rendering index shall not be less than 70 and Correlated Colour Temperature is 6500K and light should complying ISI and BIS marking,having inbuilt surge protection device for overvoltage protection with all accessories prewired and making connection with 3 core copper flexible cable of size 23/.0076 from ceiling rose/PVC connector to light fitting and shall be fitted on new plastic square/round block complete all as per specified and directed.
Material and labour for rewinding of stator assembly of exhaust fan 300mm sweep after strip opening of motor with proper grade/guage of super enamelled copper wiring incl all insulating materials, re-assembling and replacement of worn out nuts, bolts, rubber bushes, clamps etc complete all as specified and directed by Engr-in-Charge. Note :- Taking down cleaning, greasing and re-fixing in position etc.
Supply and fix in repairs sheet metal enclosure powder painted for MCB DB SPN 8 way double door with din rail and bus bar complete all as specified and directed.
Supply and fix in repairs sheet metal enclosure powder painted for MCB DB SPN 12 way double door with din rail and bus bar complete all as specified and directed.
Supply and fix in repairs MCB SPN 240 Volts 6 Amp to 32 Amp breaking capacity 10 KA rating complete all as specified and directed.
Supply and fix in repairs MCB SP 240 Volts 6 to 32 Amps B Curve breaking capacity 10 KA rating complete all as specified and directed.
M & L for earthing complete with Galvanised steel earth plate electrode 60 cm x 60 cm x 6 cm thick buried directly in ground vertically at a depth not less than 2.25 m below normal ground level with top level of earth plate at depth not less than 1.5 m below normal ground level surrounded form all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connection by using GI strip 32 mm x 6 mm by means of bolts, nuts, check nuts and washers of galvanized iron upto test point and protected by GI pipe light grade 40 mm bore up to 7.5 Mtr connected to a main switch board or main control board and GI pipe light grade 20 mm bore for watering and including funnel, wire mesh, 80 mm thick pre-cast RCC 1:2:4, type B-1 cover reinforced with hard drawn steel wire fabric weighing not less than 4 Kg/Sqm in lieu of CI cover, PCC 1:3:6 type C2 pit / chamber including all necessary excavation and earth work, disposal of surplus soil to a distance not exceeding 50 m all as specified and as shown in Electrical Plate No 3 of MES Schedule Part – I of 2009.
M&L for secure/hanging of electrical LT XLPE/PVC cable/wires of any size on walls/ceiling/store houses with clamps, hooks, nuts , bolts and other accessories for electrical hyigen complete all as specified and directed. Note : Please refer Store houses hight will be approximate 12 meter.
M & L for electronic circuit PCB for BLDC Ceiling fan of 1200 mm sweep as per OEM etc complete all as specified and directed.
Deduct Credit for Demolished/ Dismantled material Rs. (-) 1,25,380.00 (Minus) as listed in Schedule of Credit Note1: Tenderers will not quote against this item being a tentative amount to be considered to arrive at the 'Contract Sum' Note 2:- The tenderer must keep in mind when quoting rates against items out in multiple store house having height 4 mts to 7 mts. Necessary scaffolding and saftey measures required during execution of work are including in this items.
S K ENTERPRISES
R J ENTERPRISES
Joy builders
VIJAY ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .