Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.3 CrAccepted-AOC POST BOX NO 539 JUNGLIGHAT P O SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744103 | ₹5.3 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹47.5 Cr+₹42.2 Cr (796.8%)Rejected-AOC | ₹47.5 Cr+₹42.2 Cr (796.8%) | L2 | Rejected-AOC Not Being L1 |
| 3 | Rejected-Technical | - | - | Rejected-Technical Not recommended being three class below the eligible class |
Tender Value
₹4.5 Cr
EMD Value
₹5.3 L
Closing Date
28 Sept 2019, 6:00 pmClosed
Chief Engineer AN Zone
Headquarters Chief Engineer AN Zone Military Engineer Services Birchgunj Junglighat Post Port Blair 744 103
PROVN OF OTM ACCOMODATION AT BUNIYADABAD, HADDO, PORTBLAIR
2018_MES_228256_4
801127E8
Open Tender
Civil Works
Lump-sum
600 days
PORT BLAIR
Please refer Tender documents.
8 documents required · 8 mandatory
₹2,000
GE (P) Central
₹5.3 L
Yes
28 Jul 2020
31 Jul 2019
30 Sept 2019
31 Jul 2019
28 Sept 2019
14 Aug 2019
31 Jul 2019 - 7 Aug 2019
Amount
GENERAL SUMMARY NOTE: Schedule ‘A’ Part I to XI are prepriced by MES under Ser No. 1.00 to 11.00. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Lumpsum price worked out by the contractor for "Building / Structures” as listed in Schedule ‘A’ Part - I, inserted by MES
Lumpsum price worked out by the tenderer for "Excavation and Earth work including site clearance and Land Development" as listed in Schedule 'A' Part-II
Lumpsum price worked out by the tenderer for "Internal Water Supply" as listed in Schedule ‘A’ Part-III
Lumpsum price worked out by the tenderer for "Internal Electrification" as listed in Schedule ‘A’ Part-IV
Lumpsum price worked out by the tenderer for "External Water Supply" as listed in Schedule ‘A’ Part-V
Lumpsum price worked out by the tenderer for "External Electric Supply" as listed in Schedule ‘A’ Part-VI
Lumpsum price worked out by the tenderer for "Roads/Paths/Culvert" as listed in Schedule ‘A’ Part-VII
Lumpsum price worked out by the tenderer for "Sewage Disposal " as listed in Schedule ‘A’ Part-VIII
Lumpsum price worked out by the tenderer for "Area Drainage" as listed in Schedule ‘A’ Part-IX
Lumpsum price worked out by the tenderer for " Retaining Wall" as listed in Schedule ‘A’ Part-X
Lumpsum price worked out by the tenderer for " Demolition and Dismantling" as listed in Schedule ‘A’ Part-XI
Subtotal
NOTE: Schedule ‘A’ Part - XII is not prepriced by MES and prepriced rate indicated as 0.00 under Col.5 signifies this fact only. Bidder shall insert their rates in Green colour filled under Col-6.
SCHEDULE `A' PART - XII (MISC ITEMS) (EXCAVATION & EARTHWORK INCLUDING SITE CLEARANCE AND LAND DEVELOPMENT) Supply approved earth obtained from outside of MoD land and forming embankment including raising (or lowering) earth, spreading in layers n.exc. 30cm thick, watering, rolling under optimum moisture content, finishing to required size and shape n.exc.1.5m high from base complete all as specified and as directed.
(INTERNAL ELECTRIFICATION) Supply and fixing LED tube light fittings 1 x 18 W 230V, wall/ceiling mounting LED battern with extruded aluminium housing and roubust construction prewired for LED tube complete fixed to wall/ceiling by suitable PVC round blocks and connection by flexible PVC cable with stranded copper conductor from ceiiling rose to connector of the fitting including 1 Nos of 18W LED tubes complete all as specified and as directed. Make: Havells cat No. LHEXBTPTUN/W018 or equivalent in Philips/ HPL / LUKER
Supply and fixing LED tube light fittings 1 x 9 W 230V, wall/ceiling mounting LED battern with extruded aluminium housing and roubust construction prewired for LED tube complete fixed to wall/ceiling by suitable PVC round blocks and connection by flexible PVC cable with stranded copper conductor from ceiiling rose to connector of the fitting including 1 Nos of 9W LED tubes complete all as specified and as directed. Make: Havells cat No. LHEVBTPTUN/W009 or equivalent in Philips/ HPL / LUKER
Supply and fix TV socket outlet complete all as specified and as directed.
S&F RJ 11 Telephone Jack single with shutter complete all as specified and as directed.
S&F LED Bulb 7w ,cap type B22, cool white 230 volt, complete all as specified and as directed. Make:Philips/ Havells/ Bajaj/ LUKER
Supply and fixing ceiling fan 5star rated 1200 mm sweep ISI marked and connecting up including provision of 3 core flexible PVC cable with stranded copper conductor of size 0.75 Sq.mm from ceiling rose to connector of ceiling fan. Make :Usha/ Crompton Greaves/ Bajaj.
Supply and Fixing ISI marked Exhaust fan heavy duty type with double ball bearing, continuous rated along with GI louvers for protection when not in use, silent operation, rust proof body and blades, MS grade for rodent protection with fixing arrangements of size 300mm sweep and connecting up including provision of three core flexible PVC cable with stranded copper conductor of size 1.5 Sq.mm from ceiling rose to connector of ceiling fan complete all as specified and as directed. Make : Usha / Bajaj / Crompton greaves.
Supply and fix sheet metal enclosures 6 way with provision of SPN MCB 20/32Amps capacity as incomer and SP MCBs as outgoing 220 volts including earth bars and neutral links complete all as specified and as directed. Make: L&T/ C&S / Havells/ Legrand.
Supply and fix sheet metal enclosures (MCB DB) factory made, distribution board TPN, 4 ways (4+12way) fitted with busbars, earth bar and neutral links, with IP 43 protection and acrylic door, suitable for mounting TPN 40/63amp MCBs as incomer and SP MCBs / TPN MCBs as outgoing 415 volts complete all as specified and as directed. Make: L&T/ C&S / Havells/ Legrand.
Supply and fix sheet metal enclosures (MCB DB) factory made, distribution board TPN, 6 ways(4+18way), fitted with busbars, earth bar and neutral links, with IP 43 protection and acrylic door, suitable for mounting TPN 40/63amp MCBs as incomer and SP MCBs / TPN MCBs as outgoing 415 volts complete all as specified and as directed. Make: L&T/ C&S / Havells/ Legrand.
Supply and fix MCB four pole 415 volts 50Hz, 32 amps, breaking capacity 10KA. complete all as specifed and as directed. Make:Legrand/ L&T/ C&S/ Havells.
Supply and fix MCB four pole 415 volts 50Hz, 40 amps, breaking capacity 10KA. complete all as specifed and as directed. Make:Legrand/ L&T/ C&S / Havells.
Supply and fix MCB four pole 415 volts 50Hz, 63 amps, breaking capacity 10KA. complete all as specifed and as directed. Make:Legrand/ L&T/ C&S/ Havells.
Supply and fix MCB single pole 240 volts, 6 to 32 amps.B curve 10 KA . complete all as specifed and as directed. Make:Legrand/ L&T/ C&S/ Havells.
Supply and fix MCB SPN,6 to 32 amps capacit 230 volts 10 KA, C curve, complete all as specifed and as directed. Make:Legrand/ L&T/ C&S/ Havells.
Material & labour for Earthing complete with galvanised iron earth plate electrode of size 60cm X 60cm X 6mm thick burried directly in ground vertically at a depth not less than 2.25 mtr below normal ground level with top edge of earth plate at a depth not less than 1.5 mtr below normal ground level, earth plate surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using galvanised iron wire 4 Sq.mm by means of bolts, nuts, check nuts and washers made of GI and protected by light grade 20mm dia galvanised iron pipe connected to main switch board or main control board and GI pipe light grade 20mm bore for watering and including funnel with wire mesh, RCC pit cover and PCC chamber pit with PCC 1:2:4 type B-2 (including necessary excavation and earth work disposal of surplus soil to a distance not exceeding 50 mtr all as specified and shown on plate No 3 of SSR Part-I 1991.
EXTERNAL WATER SUPPLY Material & labour for cutting the existing pipe line 100mm dia and Fixing PPR Tee 110x110x75 mm 3 Layer PP-R Pipe (Polypropylne random copolymer ) conceled pipes SDR 7.4 (PN1.6) branch incl cutting connected from existing 100 mm GI line by provding and making fusion joint, complete all as specified with all accessories as required at site for branch connection including cutting threading and earth work in any strata complete all as specified and as directed .
Material & labour for Construction of masonry valve chamber of size 600x600x600mm internal size, 150 mm thick foundation using PCC 1:4:8, type D-2, over 15cm thick hard core, 20cm thick solid block masonry with blocks cast using PCC 1:3:6, type C-1, set in cement mortar 1:6, 15mm thick plaster to internal surfaces and external surfaces up to 15cm below ground level and top of floor in cement and sand mortar 1:4, finished even and smooth without using extra cement , 3.15mm thick MS sheet cover including 40x40x6mm thick MS angle frame fixed in PCC 1:2:4, type B1 coping with 25x6mm flat iron hold fasts, handle, hinges with locking arrangements, applying one coat of red oxide primer and two coats of black bituminous paint to all steel surfaces and earth work in any type of soil including disposal of surplus soil to a distance not exceeding 50M complete all as specified and directed.
Material & labour for Construction of masonry valve chamber of size 900x900x900mm internal size, 150 mm thick foundation using PCC 1:4:8, type D-2, over 15cm thick hard core, 20cm thick solid block masonry with blocks cast using PCC 1:3:6, type C-1, set in cement mortar 1:6, 15mm thick plaster to internal surfaces and external surfaces up to 15cm below ground level and top of floor in cement and sand mortar 1:4, finished even and smooth without using extra cement , 3.15mm thick MS sheet cover including 40x40x6mm thick MS angle frame fixed in PCC 1:2:4, type B1 coping with 25x6mm flat iron hold fasts, handle, hinges with locking arrangements, applying one coat of red oxide primer and two coats of black bituminous paint to all steel surfaces and earth work in any type of soil including disposal of surplus soil to a distance not exceeding 50M complete all as specified and directed.
EXTERNAL ELECTRIC SUPPLY Supply and erect pre cast RCC pole 9 m long of size 380x250mm at bottom and 150 x 125mm at top in M-30 design mix, reinforcement with high strength deformed steel TMT bars, necessary form works and erecting in position including, writing pole numbers of approved font and size and painting alternates bands with yellow and black column up to 1.5 mtrs height above coping etc,. complete all as specified. Note- (i) RCC pole 9 m long shall be provided all as shown on TD drawing No. TD 401 sheet 1/1 dated 11/09/06. (ii) The rate quoted deemed to incude the following provisions also. (a) Excavation in any type soil, returning filling and removal of surplus soil to a distance of 50 m (b) Foundation PCC (1:2:4) type B2 using 40mm graded stone aggregate (c) Coping to poles in (1:2:4) type B0 using 12.5mm graded ston aggregate. (d) Necessary agrangements for bailing out the water during the excavation.
Supply and erect pre cast RCC pole 11 m long of size 380x250mm at bottom and 150 x 125mm at top in M-30 design mix, reinforcement with high strength deformed steel TMT bars, necessary form works and erecting in position including writing pole numbers of approved font and size painting alternates bands with yellow and black column up to 1.5 mtrs height above coping etc,. complete all as specified. Note- (i) RCC pole 11 m long shall be provided all as shown on TD drawing No. TD 401 sheet 1/1 dated 11/09/06. (ii) The rate quoted deemed to incude the following provisions also. (a) Excavation in any type soil, returning filling and removal of surplus soil to a distance of 50 m (b) Foundation PCC (1:4:8) type B2 using 40mm graded stone aggregate (c) Coping to poles in (1:2:4) type B0 using 12.5mm graded stone aggregate. (d) Necessary agrangements for bailing out the water during the excavation.
Supply and fixing Street light Luminaries LED type of 25 Watt, New generation energy saving comprising of epoxy powder coated housing, enclosed with glass cover Suitable for 35/40mm OD pipe , Ingress protection IP66 with G.I bracket made out of 32 mm GI pipe, medium grade including GI clamps nut bolts washer complete as specified and directed by Engineer-in-Charge. (Model: LHETAXU7PNW048of Havells or its equivalent in Bajaj,Phlips, Crompton, LUKER)
Supply and fix junction box made out of poly carbonate plastic material of size 10x8x4 inch, with provision of single phase cable connector incoming and out going with MCB SP 6 Amps for street light fitting/PTL IP 65 protection totally enclosed weather proof with cable entry alongwith GI clamps nut bolts & washer complete all as per required at site and fixed on pole all as directed. Make: Sintex/OBO/Hensel
M&L for earthing complete with Galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below GL) with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanised strip of size 32x6mm connected by means of bolts, nuts, check nuts and washer of galvanised iron or steel, provision of 40 mm dia GI pipe medium grade for protection of GI earth strip and 20mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) , type C1 chamber, MS funnel with wire mesh, 50 mm thick RCC 1:2:4, type B1 earth pit cover with 6 Nos, 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n exc 50 mtr, provision of charcoal and salt complete all as shown in electrical plate No 3 of schedule Part-I
Supply & install ,commissioning ,testing of out door type Transformer step down 11000/440 volt copper winding 3 phase 4 wire of capacity 100 KVA ,50 Hz oil immerged ONAN cooling ,vector group DYN -11 confirming to IS-1180-2014, completed with delta on HT side star on LT side with standard fitting /fixture cable gland and natural brought out complete with first fill of transformer oil to appropriate level temperature gauge breather conservator tank and cooling radiator incl mounting the tranformer on PCC platform incl foundation & PCC platform complete all as specified and directed by Engr-in-Charge .
Supply & fixing of DWC ( double Wall corrugated ) HDPE pipe Outer Dia of 145mm and inner Dia 126 mm ISI marked with smooth internal and profiled external surfac e for non pressure under ground cable incl all connected accesssories like socket coupler bends tees etc for protection of 95 sqmm 3 core HT cable and 95 sqmm 3.5 core LT cable complete all as spdf and directed .
Supply & fixing of DWC ( double Wall corrugated ) HDPE pipe Outer Dia of 90 mm and inner Dia 76 mm ISI marked with smooth internal and profiled external surfac e for non pressure under ground cable incl all connected accesssories like socket coupler bends tees etc for protection of 35 Sqmm 3.5 core LT cable complete all as spdf and directed .
Supply & fixing of DWC ( double Wall corrugated ) HDPE pipe Outer Dia of 50 mm and inner Dia 38 mm ISI marked with smooth internal and profiled external surfac e for non pressure under ground cable incl all connected accesssories like socket coupler bends tees etc for protection of 10&16 Sqmm 4 core LT cable complete all as spdf and directed .
Supply and lay pulverized stone dust to the full width of trenches for protection of cables including spreading and punning complete all as specified and directed Note: Punned thickness only will be considered for payment
HOT WATER SUPPLY Supply & fixing type water heater of 25 ltrs capacity 5 star rating complete with stainless steel water tank and operation assembly, glass wool/puf insulation, 1.5 KW hearing element, thermostat, safety valve, NRV with inlet and outlet hot/cold CP flexible pipe connection, grouting with suitable type fastener complete all as specified and directed.
COOLING APPLIANCES Supply and fixing water cooler stainless steel electric driven (single phase) having approx storage capacity of 80 Ltr and Nominal cooling capacity 40 Ltr Per Hours, complete all as specified and as directed.
Supply and fixing voltage stabilizer for a automatic operation single phase naturally air cooled indoor type & designed for input variation between 170V to 250V with output voltage stabilizer at 230V with accuracy of ± 2.5 and of capacity of 1.0 KVA, complete all as specified and as directed.
Supply and fixing water purified RO system and pre filter 5 Micron of capacity 25 Ltrs / Hrs, complete all as specified and as directed.
CABIN FAN Supply and Fixing Air circulator Fan type electric driven 230 volt single phase 50 Hz 450 mm sweep suitable for ventilation wall mounted type with complete fitting all as spdf and diredted .
DEMOLITION AND DISMANTLING Taking down Ceilling Fan and handing over to store , complete all as specified and as directed by Engineer-in-charge.
Taking down Electric Meters and handing over to store , complete all as specified and as directed by Engineer-in-charge.
Taking down Geyser and handing over to store , complete all as specified and as directed by Engineer-in-charge.
Taking down of point wiringwith all accessories and fitting , complete all as specified and as directed by Engineer-in-charge.
Taking down of main switch/ DBs including MCB's, complete all as specified and as directed by Engineer-in-charge.
Taking down of service connection with all fittings, complete all as specified and as directed by Engineer-in-charge.
Taking up of pipe of any sizes, complete all as specified and as directed by Engineer-in-charge.
Subtotal
AMR TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .