Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance NA JETALPUR ROAD B H AGRAWAL GUEST HOUSE BARODA GUJARAT 390007 | VADODARA | GUJARAT | 390007 | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
Closing Date
16 Jul 2022, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
DGM (PJ)
Indian Oil Corporation Limited Paradip Refinery PO- Jhimani, Via-Kujang, District-Jagatsinghpur Odisha-754141 Tel No- 06722-255804
Supply and Installation of Cathodic Protection (CP) system for completion of balance of CLT and other off-site facilities under LSTK-2 package of PP Rath-chakra Project at Paradip Refinery
2022_PDR_153431_1
PDO3P22111
Single
Services
Works
365 days
INDIAN OIL CORPORATION LIMITED PARADIP REFINERY
Please refer Tender documents.
5 documents required · 5 mandatory
Exempted
18 Jul 2022
9 Jul 2022
18 Jul 2022
9 Jul 2022
16 Jul 2022
9 Jul 2022
Amount
SUPPLY OF MATERIALS
Thermit Weld connection kit for cable welding with pipeline
1Cx10mm2 Cu XLPE / PVC unarmoured cable for Anode tail cable.
1C x 2.5mm2 Cu XLPE/PVC FRLSH/650V un-armoured cable for Ref Electrode & Measurement Point.
Polarization coupons for OFF PSP Measurement of dimension 50mm x 50mm x 10mm Thick MS Plate +/-10%
Supply of Permanent Reference electrode (Ag\AgCl) Potentials : (+)62mV (+)10mV wrt to Standard Calomel Reference
Supply of Titanium Tube – ASTM Grade – I / II MMO anodes with dia 25.4mm / 1in OD + 5% and 500 mm length for Horizontal Shallow Anode bed
WP Anode junction Box IP65 Non Classified Configuration: Positive incoming DC supply from CPTR is distributed into 2Nos + 2Nos Spare outgoing anode circuits in line with current measurement shunts. No. Of Circuits: 04 Nos. Circuits including spare.
WP Cathode junction Box IP65 Non Classified Configuration: Negative incoming DC supply from CPTR is distributed into 04 negative drain circuits in line with current measurement shunts. Number of Circuits: 04 Nos. Including spares.
Soil Access Points (PVC pipe diameter 90mm /40sch)
1Cx35mm2 Cu XLPE/PVC FRLSH/650V unarmored cable for positive and negative drainage cables
1Cx10mm2 Cu KYNAR/HMWPE/650V ununarmored cable for Anode tail cable.
3C x 25sq.mm - Power Supply cable between Power PDB in S/S & TR unit (Al, Al wire armoured, PVC insulated and PVC sheathed)
3Cx10mm2 Cu XLPE/PVC FRLSH unarmored cable for AC power Supply cables between PDB and TR Unit
Consumables for balance works to make the CP system operationa A. 5 Nos.Cable gland for 3Cx 25sqmm cables B. 10 Nos.Cable gland for 3Cx 10sqmm cables C. sealing material D. 60 Nos. Ring type lugs for 1Cx10sqmm cables and ferrule for each cable termination etc.
Portable Reference electrode (Ag\AgCl) (03”Diameter / Rating 4-6kg/cm2 x 300mm Long (SCH40))
Digital Multi Meter of reputed make with accuracy +- 0.1%.
Surge Diverter @ 100KA for IJ Protection
Test Stations (Big Fink Polycarbonate Enclosure. Cable entries is through support conduit PVC pipe) Circuit Configuration: Cathodic Protection Cable Terminations for Measurement Point, Drain Point and Sacrificial Anodes
Power Distribution Board as per specifications. (12 way, 63 A, 1No. incomer: 16A, 7 Nos. outgoing feeders) Incoming cable size : 3C X 25 sqmm, Outgoing cable size : 3C X 10 sqmm.
INSTALLATION/TESTING/COMMIS
Excavation, back-filling, levelling, dressing, required tools for Thermit Weld connection for cable welding
Excavation, back-filling, levelling, dressing, required tools & tackles for laying of underground cable of size 1Cx10mm2 Cu XLPE / PVC unarmoured cable for Anode tail cable.
Laying of underground cable of size 1C x 2.5mm2 Cu XLPE/PVC FRLSH/650V un-armoured (Sheath Color - BLACK)cable for Ref Electrode & Measurement Point.
Excavation, back-filling, levelling, dressing, required tools & tackles for Polarization coupons for OFF PSP Measurement of dimension 50mm x 50mm x 10mm Thick MS Plate +/-10%
Installation, erection, excavation, back-filling, levelling, dressing, replacement of damaged ones with required tools & tackles for Permanent Reference electrode (Ag\AgCl) Potentials : (+)62mV (+)10mV wrt to Standard Calomel Reference
Installation, erection, excavation, back-filling, levelling, dressing, replacement of damaged ones with required tools & tackles for Supply of Titanium Tube – ASTM Grade – I / II MMO anodes with dia 25.4mm / 1in OD + 5% and 500 mm length for Horizontal Shallow Anode bed
Installation and erection of WP Anode junction Box IP65 Non Classified Configuration: Positive incoming DC supply from CPTR is distributed into 2Nos + 2Nos Spare outgoing anode circuits in line with current measurement shunts. No. Of Circuits: 04 Nos. Circuits including spare.
Installation and erection of WP Cathode junction Box IP65 Non Classified Configuration: Negative incoming DC supply from CPTR is distributed into 04 negative drain circuits in line with current measurement shunts. Number of Circuits: 04 Nos. Including spares.
Excavation, back-filling, levelling, dressing, required tools & tackles for erection of Soil Access Points (PVC pipe diameter 90mm /40sch)
Excavation, back-filling, levelling, dressing, required tools & tackles for laying of underground cable of size 1Cx35mm2 Cu XLPE/PVC FRLSH/650V unarmored cable (Sheath Color – BLACK/RED for positive BLACK for negative drainage )for positive and negative drainage cables
Excavation, back-filling, levelling, dressing, replacement of damaged ones with required tools & tackles for laying of underground cable of size 1Cx10mm2 Cu KYNAR/HMWPE/650V (Sheath Color - RED) ununarmored cable for Anode tail cable.
Excavation, back-filling, levelling, dressing, required tools & tackles for laying of underground cable of size 3C x 25sq.mm - Power Supply cable between Power PDB in S/S & TR unit (Al, Al wire armoured, PVC insulated and PVC sheathed).
Excavation, back-filling, levelling, dressing, replacement of damaged ones with required tools & tackles for laying of underground cable of size 3Cx10mm2 Cu XLPE/PVC FRLSH unarmored cable for AC power Supply cables between PDB and TR Unit.
Other technical services with respect to Consumables instalation like Cable gland, sealing material, lugs, ferrule etc inclusive of replacement of perceived damages during site execution.
Installation and rectification of Surge Diverter @ 100KA for IJ Protection.
Excavation, back-filling, levelling, dressing, replacement of damaged ones with required tools & tackles, installation of new Test stations along with checking & rectification of already installed Test Stations (Big Fink Polycarbonate Enclosure. Cable entries is through support conduit PVC pipe) Circuit Configuration: Cathodic Protection Cable Terminations for Measurement Point, Drain Point and Sacrificial Anodes
Installation and erection of outdoor CP TR Unit in Non Classified area on concrete plinth foundation CP TR Unit 50V / 100A –IP65 Outdoor / Indoor Type – Non Classified Type.
Installation and erection of of outdoor PDB in Non Classified area Power Distribution Board –Non Classified.
Testing & Commissioning of PCP System.
As Built and complete drawings and documents Submission to Consultant/Client.
stage.html
html • 0.02 MB
finance_163721.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .