Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Rejected-Technical | Rejected-Technical document are NOT as per requirement |
Tender Value
₹25 L
EMD Value
₹25,000
Closing Date
5 Jan 2023, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE,EDC-IV,LESA-CISS GOMTI,MVVNL
4/82-83, INDERLOK HYDEL COLONY, KRISHNANAGAR, LUCKNOW
ON SITE Preventive maintenance of Medium Power Distribution T/F (10, 16, 25 , 63 to 100 KVA) installed at various site under the Jurisdiction of EDC-IV, Cis Gomti, Lesa, Lucknow
2022_MVVNL_752090_2
76/EDC-IV/LESA/2022-23
Open Tender
Miscellaneous Works
Fixed-rate
180 days
LUCKNOW
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
A/C-1444100402,IFSC Code-CBIN0280139
₹25,000
18 Jan 2023
31 Dec 2022
5 Jan 2023
31 Dec 2022
5 Jan 2023
31 Dec 2022
Amount
Removing Top Cover Plate by opening of Bolt and nuts of T/F and other internal connection of T/F required for repairing safely and reconnect it after appropriately after Minor repairing work of Medium Power Distribution Transformer(l l/O.4 KV) installed at various site for Stopping Oil leakage from T/F, Replacement of Damaged H.T/LT Bushing Rod and other work as per site requirement & site conditions. Firm has to make arrangement for draining and refilling of T/F Oil , if required for carrying out the work. (Distance of 50 Km. from concerned store)
10, 16, 25 KVA T/F
63 and 100 KVA T/F
Toping Up/Filling of Reclaimed T/F Oil in T/F's
T/F Oil in following capacity of T/F's up to 2/3rd level of conservator Tank for Distribution T/F having less Oil as per Indent placed for repairing by JE/SDO. Filling up of these T/F by Reclaimed T/F Oil upto required level and carriage of reclaimed T/F Oil, T/F drums from concerned store/site including safe loading and unloading at both ends. Complete in all respect as per site requirement( Reclaimed T/F Oil will be provided by the concerned JE(D) ( Required Vehicle & suitable Container for storage of Reclaimed T/F Oil will be arranged by the Contractor at his own cost.)
Replacement of Old and Damaged H.T Busihing rod including Oil Seal/Gaskits etc. ( 10, 16, 25, 63, 100 KVA T/F)
Removal of Old and damaged H.T Busing Rod from T/F and fixing of suitable size new H.T Busing rod made of Brass with all nuts and bolts etc. including replacement of all old/damaged Neoprene Oil seal/Gasket set by fixing suitable size New Neoprene Oil Seal/Gasket Set & as per site requirement, Complete Job in all respect. (All material will be provided by the Contractor)
Replacement of Old and Damaged L.T Bushing rod including Oil Seal/Gaskits etc. Removal of Old and damaged L.T Busing Rod from T/F and fixing of suitable size new L.T
Busing rod made of Brass with all nuts and bolts etc. including replacement of all old/damaged Neoprene Oil seal/Gasket set by fixing suitable size New Neoprene Oil Seal/Gasket Set & as per site requirement, Complete Job in all respect. ( All material will be provided by the contractor)
Stopping Oil leakage from T/F H.T/LT Bushing side.
Stopping of Oil leakage from T/F L.T/H.T Side Bushing. Removing of all damaged oil Seal/Gasket Set/Cork sheet and fixing of suitable size new Neoprene Oil seal/Gasket set/Cork sheet and tightening of H.T/LT bushing rod Complete Job in all respect. ( All material will be provided by the contractor)
Replacement of Old and Damaged LT PVC CABLE (All Material will be provided by Department)
Replace LT Aluminum unarmored XLPE/PVC Cable 4x16 Sq.mm
Replace LT Aluminum unarmored XLPE/PVC Cable 3.5X70/35 Sq.mm
Replace LT Aluminum unarmored XLPE/PVC Cable 3.5X150/70 Sq.mm
Replacement of Old and Damaged Suitable capacity of Aluminum Lugs (All Material will be provided by Contractor).
fixing of suitable capacity of lugs after removing old and damaged lugs from various capacity of PVC cable with using crimping tools.
Provision of fuse unit at LT side
To protect transformer by unbalancing and overloading, provision of fuse unit to be installed at LT side with suitable capacity of Fuse assembly ( All Material as fuse assembly, nut bolts etc. will be provided by contractor)
10, 16, 25 KVA KVA T/F
63, 100 KVA T/F
Provision of fuse unit at HT side
To protect transformer by unbalancing and overloading, provision of fuse unit to be installed at HT side with suitable capacity of Fuse assembly ( All Material as fuse assembly, nut bolts etc. will be provided by contractor)
10, 16, 25 KVA KVA T/F
63, 100 KVA T/F
Repair and Maintenance of Old and Damaged Transformer Earthing
Maintenance and repair of Transformer Body and Neutral Earthing PIPE/ROD are Damaged, in case of missing pole earthing, provision of M.S Rod Of 20x25mm and 6 SWG earthing wire .will be done by new one as per site requirement. Contactor to ensure that earth connection properly should be tight and earth resistance should be less then 01ohm.(All Material Provide by contactor)
GST Extra as per Rules
R.S. INDUSTRIAL WORKS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .