Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.5 LAccepted-AOC | ₹36.5 L Quoted ₹37.2 L | L1 | Accepted-AOC Accepted due to lowest rate quoted |
| 2 | L2₹37.6 LRejected-Finance NOT FOUND | ₹37.6 L | L2 | Rejected-Finance Rejected due to highest rate quoted |
| 3 | L3₹47.0 LRejected-Finance | ₹47.0 L | L3 | Rejected-Finance Rejected due to highest rate quoted |
| Sl No | Description | Qty | Unit | KISHAN SINGH AND CO L1 | shiv shanker enterprises L2 | Shiv Shakti Builders L3 |
|---|---|---|---|---|---|---|
| 1.00 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises. | 950 | Sqm | 15 ₹14,250 | 21 ₹19,950 | 20 ₹19,000 |
| 2.00 | M&L for screed bed or bedding layer of mortar 15 mm thick in cement mortar (1:6) for bedding of tiles complete all as specified. | 650 | Sqm | 80 ₹52,000 | 92 ₹59,800 | 120 ₹78,000 |
| 3.00 | M&L for 10 mm thick rendering in cement mortar (1:4) on vertical surfaces for backing of tiles complete all as specifed. | 300 | Sqm | 100 ₹30,000 | 110 ₹33,000 | 120 ₹36,000 |
| 4.00 | M&L for Non - skid (joint free) coloured Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors/skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified. | 300 | Sqm | 650 ₹1.9 L | 510 ₹1.5 L | 650 ₹1.9 L |
| 5.00 | M&L for Coloured Vitrified Ceramic tiles 9-10 mm thick (Square/rectangular) of light Shade , polished, area of each tile not exceeding 0.36 sqm, fixed in floor/skirting etc over set and jointed in neat cement slurry and pointed in coloured cement to match with coloured tiles complete all as specified. | 300 | Sqm | 850 ₹2.5 L | 621 ₹1.9 L | 700 ₹2.1 L |
| 6.00 | M&L for non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangle) area of each tile exc 0.06 sqm but not exc 0.11 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the tile complete all as specified and as directed. | 50 | Sqm | 600 ₹30,000 | 510 ₹25,500 | 600 ₹30,000 |
| 7.00 | M&L for Glazed ceramic coloured tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified. | 300 | Sqm | 700 ₹2.1 L | 490 ₹1.5 L | 700 ₹2.1 L |
| 8.00 | Demolition of Mud in roofs, any thickness including plastering and leeping, (whether full thickness removed etc including roof tiles complete all as specified and as directed. | 21.25 | Cum | 250 ₹5,312.50 | 90 ₹1,912.50 | 500 ₹10,625 |
| 9.00 | Demolition of cement concrete (un-reinforced) of any description & in any position not specifically provided complete including dismantling of floor tiles etc complete all as specified. | 20.5 | Cum | 100 ₹2,050 | 170 ₹3,485 | 200 ₹4,100 |
| 10.00 | M&L for 50 mm thick PCC (1:2:4) type B-0 (Using 12.50mm graded stone aggregate) as in roof padding complete all as specified & as directed. | 220 | Sqm | 140 ₹30,800 | 197 ₹43,340 | 200 ₹44,000 |
Updated dates
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
6 Jan 2026, 6:00 pmClosed
GE (AF) GURGAON
GE (AF) GURGAON
REPAIR/REPLACEMENT OF FLOORING SANITARY FITTING SUNKEN TREATMENT LEAKAGE/SEEPAGE IN CERTAIN MARRIED/OTM ACCN INCLUDING INTERNAL E/M WORKS AT AF STN RAJOKRI UNDER GE (AF) GURGAON
2025_MES_743709_1
GE/GUR-/NIT-102/2025-26
Open Tender
Civil Works
240 days
GE (AF) GURGAON
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) GURGAON
₹90,000
17 Feb 2026
9 Dec 2025
8 Jan 2026
9 Dec 2025
6 Jan 2026
23 Dec 2025
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises.
M&L for screed bed or bedding layer of mortar 15 mm thick in cement mortar (1:6) for bedding of tiles complete all as specified.
M&L for 10 mm thick rendering in cement mortar (1:4) on vertical surfaces for backing of tiles complete all as specifed.
M&L for Non - skid (joint free) coloured Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors/skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified.
M&L for Coloured Vitrified Ceramic tiles 9-10 mm thick (Square/rectangular) of light Shade , polished, area of each tile not exceeding 0.36 sqm, fixed in floor/skirting etc over set and jointed in neat cement slurry and pointed in coloured cement to match with coloured tiles complete all as specified.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangle) area of each tile exc 0.06 sqm but not exc 0.11 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the tile complete all as specified and as directed.
M&L for Glazed ceramic coloured tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified.
Demolition of Mud in roofs, any thickness including plastering and leeping, (whether full thickness removed etc including roof tiles complete all as specified and as directed.
Demolition of cement concrete (un-reinforced) of any description & in any position not specifically provided complete including dismantling of floor tiles etc complete all as specified.
M&L for 50 mm thick PCC (1:2:4) type B-0 (Using 12.50mm graded stone aggregate) as in roof padding complete all as specified & as directed.
M&L for 15 mm thick plaster in cement mortar (1:4) mixed with water proofing compound on roof slabs finished even and smooth (without using extra cement) after cleaning of roof surfaces with wire brushes complete all as specified.Notes : WPC shall be measured and paid seperately.
M&L for water proofing treatment with APP (Atactic Polypropylene) modified polymeric prefabricated five layer membrane over roof consisting of cleaning of concrete or plaster surface of roof & parapet walls and applying evenly a bitumen primer confirming to IS 3488 @ 0.40 Kg per sqm laid using buten torch and sealing all joints of APP modified polymeric water proofing membrane minimum weight 3.6 kg/sqm reinforced with non woven polyester fabric (weight not less than 160 grams per sqm) unrolled and bonded to substrata with logitudinal and end laps 100 mm and 150 mm respectively as per manufacturer's instructions complete all as specified.
Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified.
M&L for providing plain cement concrete (1:2:4) type B0 (using 12.5 mm graded crushed stone aggregate) as in coping in chajjas or roof kerbs on roof chamfered on edge including trowelling slightly complete all as specified.
M&L for Cement concrete tiles 25cm x 25cm x 22 mm thick, machine pressed; set jointed and pointed in neat cement slurry in floors, and cut and polished, set with grey cement and pigments over 15mm thick cement screed bed in cement mortar 1:4 complete all as specified and directed.
Supply only intergral water proofing compound ISI Marked complete all as specified.
Removing bldgs demolished materials / debries exc. 1.50 km but n exc. 5 km and depositing where directed.
M&L for preparation of plastered or unplastered old decorated surfaces by complete removal of existing treatment by scrapping with Trucare Wall Sander : L-01/H-01 (having mechanical vaccum mechanism) having RPM not less than 1500, sand pad of 80 grit having dia of 7"/9" to make the surface free from dust, loose paint etc or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible , filling of holes and cracks with with suitable material like cement or plaster of paris etc and thereafter applying two coat of oil bound distemper over a coat of primer on walls complete all as specified and as directed. Note : (a) Each stage of complete removal of existing treatment and preparation of surfaces after applying putty shall be got approved from Engg-In-Charge in stage passing register before applying the finishes coat. (b) Material shall be procured from manufacturer and work shall be got executed through authorised applicators of manufacturer. (c) Wall care putty shall be measured and paid seperately.
All as per item No.11 here-in-before but on surfaces of ceiling.
M&L for preparation(complete removal of existing treatment) of old decorated external wall/ceiling surface of existing treatment by scrapping with Trucare Wall Sander : L-01/H-01 (having mechanical vaccum mechanism) having RPM not less than 1500, sand pad of 80 grit having dia of 7"/9" to make the surface free from dust, loose paint etc or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible and applying Two coats of wheather proofing exterior acrylic emulsion paint over a coat of primer premium quality on wall/ceiling surface including applying 1-2mm thick wall care putty over disturbed surface during preparation of any reason, sand papering thus make surface smooth upto 4th storey buildings complete all as specified and as directed. Note : (a) Each stage of complete removal of existing treatment and preparation of surfaces after applying putty shall be got approved from Engg-In-Charge in stage passing register before applying the finishes coat. (b) Material shall be procured from manufacturer and work shall be got executed through authorised applicators of manufacturer.
M&L for preparation(complete removal of existing treatment) of old decorated external wall/ceiling/roof sheet surface of existing treatment by scrapping with Trucare Wall Sander : L-01/H-01 (having mechanical vaccum mechanism) having RPM not less than 1500, sand pad of 80 grit having dia of 7"/9" to make the surface free from dust, loose paint etc or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible and applying Two coats of wheather proofing exterior acrylic emulsion paint ( Camouflage Pattern) over priming coat premium quality on wall/ceiling surface including applying 1-2mm thick wall care putty over disturbed surface during preparation of any reason, sand papering thus make surface smooth upto 4th storey buildings complete all as specified and as directed. Note : (a) Each stage of complete removal of existing treatment and preparation of surfaces after applying putty shall be got approved from Engg-In-Charge in stage passing register before applying the finishes coat. (b) Material shall be procured from manufacturer and work shall be got executed through authorised applicators of manufacturer.
M&L for providing 3mm thick wall care putty on wall before applying oil bound distemper and making the surface uniform all as specified. Note: OBD to be measured and paid saperately.
M&L for providing 3mm thick wall care putty on ceiling before applying oil bound distemper and making the surface uniform all as specified. Note: OBD to be measured and paid saperately.
M&L for preparation of old treated plastered or unplastered surfaces of walls including cornices by brooming down or steel wire brushing, scraping down, smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spot, filling cracks/holes with putty and applying one coat of distemper oil emulsion on walls complete .
M&L for preparation of old treated plastered or unplastered surfaces of ceiling including cornices by brooming down or steel wire brushing, scraping down, smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spot, filling cracks/holes with putty and applying one coat of distemper oil emulsion on ceiling complete .
M&L for preparation of old painted surfaces of wood and wood based material of any description over 10cm width or girth by cleaning, sand papering,brushing etc , filling in cavities and cracks etc with approved filler and applying one coat of synthetic enamel paint to give an even and smooth surface having no sign of brush marks complete all as specified .
M&L for preparing old painted surfaces of steel and iron surfaces over 10 cm in width or girth by cleaning, sand papering, brushing with wire brushes, scrapping by steel scrappers etc and applying one coat of synthetic enamel paint to give an even and smooth surface having no sign of brush marks complete all as specified .
M&L for preparation of old painted concrete surface plain/kerb stone moulded over 10cm width or girth by cleaning, brushing etc and applying one coat of synthetic enamel paint all as specified and as directed.
Demolition of brick work or rubbled stone masonry including all quoins arches , pillars etc built in cement mortar and including removal from the site complete all as specified.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc and including removal of debris and rubbish from the site complete all as specified.
M&L for brick work with sub class 'B' old size brick, straight or curved on plan exc 6.0 mtr mean radius built in cement mortar 1:6 etc complete all as specified.
M&L for half brick work with sub class 'B' old size brick, straight or curved on plan exc 6.0 mtr mean radius built in cement mortar 1:4 etc complete all as specified.
M&L for 5 mm thick cement plaster on fair faces of brick work or concrete surfaces in cement mortar 1:3 in ceiling including finishing surface even and smooth without using extra cement.
M&L for 10 mm thick cement plaster on fair faces of brick work or concrete surfaces in cement mortar 1:6 on walls including finishing surface even and smooth without using extra cement
M&L for 15 mm thick plaster in cement mortar (1:4) on brick or concrete surfaces including rendering on fins, fascias, chajja, parapets etc and finishing the surfaces even and fair (without using extra cement) complete all as specified.
M&L for preparation of newly plastered surface of wall and applying two coats of oil bound distemper over one coat of primer complete all as specified.
M&L for preparation of newly plastered surface of ceiling and applying two coats of oil bound distemper over one coat of primer complete all as specified
M&L for preparation of newly plastered surface of wall and applying Two coats of wheather proofing exterior acrylic emulsion paint over a coat of primer premium quality complete all as specified
M&L for preparation of newly plastered surface of wall and applying Two coats of wheather proofing exterior acrylic emulsion paint ( Camouflage Pattern) over a coat of primer premium quality complete all as specified
M&L for preparation of newly plastered surfaces of wall and applying two coats of cement base paint on walls. complete all as specified.
Disconnecting existing PVC water tank of capacity exc. 250 ltr but not exc. 500 ltr, setting aside for lowering down if required for repairs,hoisting if required reconnecting and refixing in position on roof including cleaning of Overhead tank & removing the sludge washing down with detergent/ bleaching powder and writing the date of cleaning with suitable paint complete all as specified.
Disconnecting existing PVC water tank of capacity exc.500 ltr but not exc. 1000 ltr, setting aside for lowering down if required for repairs,hoisting if required reconnecting and refixing in position on roof including cleaning of Overhead tank & removing the sludge washing down with detergent/ bleaching powder and writing the date of cleaning with suitable paint complete all as specified.
Dismantling of existing water tanks of steel/PVC/AC of capacity exceeding 250 liters but not exceeding 500 litres complete all as specified.
Dismantling of existing water tanks of steel/PVC/AC of capacity exceeding 500 liters but not exceeding 1000 litres complete all as specified.
S&F for rotational moulded polyethylene water storage tanks 500 ltrs capacity (cylinderical vertical with closed top) hoisted and fixed in position all as per SSR Part I complete all as specified.
S&F for rotational moulded polyethylene water storage tanks 1000 ltrs capacity (cylinderical vertical with closed top) hoisted and fixed in position all as per SSR Part I complete all as specified.
Taking up or down 15 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified.
Taking up or down 20 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified.
Cutting chases, pinning in. making good to facings where required andpointing in cement mortar 1:3 to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth in brick wall etc complete all as specified.
S&F medium grade galvanized steel tubing with all fittings & fixed complete to walls & ceiling or laid in floors 15 mm dia bore pipe (including in short length) complete all as specified.
S&F tubes medium grade galvanized with all fittings & fixed complete to walls & ceiling or laid in floors 20 mm dia bore pipe (including in short length) complete all as specified.
S&F in repair 20 mm dia Gun metal gate valve with iron wheel head, screwed both ends for iron pipe complete all as specified.
Dismantling wrought iron or mild steel work of any description
S&F rolled mild steel in framed work as in doors or steel gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging; also fastening and fixing conforming to Fe- 290.Gde-E-165 complete all as specified.
S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified.
M&L prepration of new Steel surfaces of any description, not otherwise described, over 10cm width or girth & applying two coats of synthetic enamel paint complete all as specified
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified & directed.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with selftapping screws as specified & directed.
S&F in repair steel rolling shutter of thickness 1.25 mm without ball bearing as specified including top cover , anchoring rod , hasp and staple and one shop coat of primer erected in position, gear operated type with bevel gear box and crank handle complete all as specified.
M&L for PCC 1:2:4 type B1 (using 20mm graded stone aggregates) as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, coping, bed plates and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work, complete all as specified.
M&L for 75 mm thick cement concrete type D-2 1:4:8 with )using 40 mm graded stone aggregates) as in sub base of flooring etc complete all as specified.
M&L sand filling under interlocking tiles for cushioning including watering and consolidation complete all as specified.
M&L for machine presssd pre-cast coloured concrete interlocking paver block any shape confirming to IS-15658-2006 of 60mm thick , M-35 Grade with grey cement and pigment as approved complete all as specified.
M&L for screed bed or bedding layer of mortar 20 mm thick in cement mortar 1:6 for laying floor finishes complete all as specified.
M&L chequered cement concrete coloured tiles 30cm x 30 cm x 25mm, set jointed and pointed in neat cement slurry in floors with grey cement and pigment complete all as specified.
M&L for cement concrete type B0 1:2:4 (using 12.50 mm graded stone aggregate) as in coping benching, gola, slightly rounded and similar items complete all as specified and as directed.
Taking down wall panelling and similar work all as specified.
S&F for solid colour wood grain printed PVC sheets 5mm thick as in wall panelling inclusive of solvent cement incl necesssary PVC frame work for fixing on brick or concrete wall as per specification and drawing.
Dismantling ceiling board (fiber, pulp insulation) or insulation board/slabs etc including grid work/wooden or aluminium frame works, cover fillet etc Complete all as specified.
M & L for clip in type armed strong metallic powder coated 0.5mm thick ceiling with GI framework made of standard Tee , Angle or any other section as in grid type ceiling framework as approved by GE . Ceiling shall be hanged to roof trusses / purlin rafters with the help of GI wire not less than 4mm dia at an interval n. exc 1m , the size of the metallic powder coated ceiling tiles 600 mm x 600 mm complete all as specified.
M&L for guniting work to RCC work in column, flooring, side walls, beam, slab, etc by removing loose concrete cover etc, cleaning of surface with wire brush and applying epoxy paint to rusted reinforcement and S&F welded wire mesh fabric or wire net less than 95 X 95X 3 mm adhesive, plaster grade for concrete admixture 1 part of cement and 3.5 part of sand and average thickness 40 mm and making the surface even including 15mm thick plastering in cement mortar (1:4) on brick or concrete surfaces including finishing the surfaces even and smooth, without using extra cement plumb and making surface true to geometry in line and including necessary form work to be carried at upto double storey building Note.- Where ever reinforcement required will be measured and paid seperatly etc complete all as specified.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) not exc 1.5 sqm each complete all as specified and directed.
All as per item No.73 here-in-before but exc 1.5 Sqm and not exc 4 Sqm each complete all as specified.
Taking down chowkhats or frames not exc. 1.5 sq. m each complete all as specified and directed.
All as per item No.75 here-in-before but exc 1.5 Sqm and not exc 4 Sqm each complete all as specified.
Taking down shutter of any description exc 1 Sqm and n exc 2 Sqm and removing from site.
S&F for Pressed steel frames 125X60mm (made out of 1.25mm thick MS Sheet) for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete as specified.
S&F for Pressed steel frames 105X60mm (made out of 1.25mm thick MS Sheet) for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete as specified.
S&F factory made 35mm thick flush shutters , solid core construction with block board core and plywood face pannel commercial type on both faces complete all as specified.
S&F factory made 35mm thick 2nd class hardwood glazed and skelton door shutters, open rebated and prepared to receive glass, gauze, (without sash bars) edges for framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass etc, sizes of members of shutters as specified in SSR Part-1 section 8 clause 8.24 (a) fitted to chowkats complete all as specified.
S&F solid PVC door frame of size 50mm X47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube supplying and fixing in opening as per specification and drawing.
S&F factory made PVC shelter panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in MS frame welded/ sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement , supplying and fixing in the frame at site as per specification & drawing as specified.
S&F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staple including necessary beading complete all as specified.
S&F in repair Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staple including necessary beading complete all as specified.
M&L preparation of new or previously untreated wooden surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and as directed.
S&F 100 mm Butt hinges, Stainless steel and fixed complete all as specified and as directed.
S&F 200mm long aluminium anodised, barrel tower bolts of extruded section complete all as specified.
S&F 150 mm size extruded aluminium alloy handles fabricated type anodised and fixed.
S&F 250 mm long aluminium alloy anodised sliding door bolts with hasp stapple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast sections or cast aluminium alloy complete all as specified and as directed.
S&F in repair 200mm long aluminium anodised, barrel tower bolts of extruded section complete all as specified.
S&F in repair 150 mm size extruded aluminium alloy handles fabricated type anodised and fixed.
S&F in repair 250 mm long aluminium alloy anodised sliding door bolts with hasp stapple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast sections or cast aluminium alloy complete all as specified and as directed.
Hacking out old broken glass (any thickness, size, quality or escription) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed.
S&F sheet glass 4 mm thick ordinary quality and glazing with oil putty or wooden beads complete all as specified.
S&F Powder coated Aluminium frame for doors, windows, ventilators with or more rebates incl. jointing cleat for fixing etc. Complete all as specified.
S&F powder coated anodized aluminum door shutters, aluminum section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing handles 2 Nos in each door,100 mm long hinges (3 Nos), anodized aluminum snap beading screws etc. complete all as specified.
S&F powder coated Anodised aluminium window and ventilator shutters, fixed/side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified.
S&F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge.
M&L for 5.5 mm thick sheet glass ordinary quality and glazing each pane fixed with including neopune rubber gasket in aluminium frame work complete all as specified and directed.
S&F window or ventilators section of frame 72x55mm fixed to wall or concrete surface with rowl plugs made of galvanised steel powder coated and section of shutter 47x20mm mulion section 72x50mm (Based steel as per IS 513 "D" quality galanised as per IS 277 with zinc of 120 gms/sqm) glazed or gauged and wire gauge shutter prepare to receive wire mesh to the shutter (Double door shutter) with total coated thickness of 0.6mm including grills/guard bars made of square bars powder coated fixed to window frame with screws including necessary fittings and all builders hardware such as handles, tower bolts and stays etc complete all as specified and as directed. Make : NCL type-4000 Series (Note : Glass and wiremesh shall be measured and paid separately under respective items)
M&L for cement concrete 1:5:10 type E-2 using 40mm graded stone aggregates as in sunken portion of WC etc complete all as specified and as directed
M&L for rendering 15 mm thick in CM (1:3) mixed with water proofing compound @ 3% by weight of cement finished even and smooth without using extra cement in sunken portion of toilet including one coat of bitumen coating of bitumen 85/25 grade at the rate of 1.2 kg per sqm including cleaning surfaces etc complete all as specified and as directed. Note: WPC will be measured and paid separately
S&F for rotational moulded polyethylene water storage tanks 5000 ltrs capacity (cylinderical vertical with closed top) hoisted and fixed in position all as per SSR Part I complete all as specified.
Taking down carefully copper / aluminium point wiring light / fan, socket or power point complete including fittings such as switches, sockets, ceiling rose, bell push bell buzzer lamp holder bracket etc. removing from site and making good disturbed surface of wall, floor etc complete all as specified and as directed.
M & L for replacement of concealed point wiring complete with PVC insulated and unsheathed FRLS cable of 1.5 sqmm (nominal area) with multi stranded copper conductor single core 1100 volts grade in and including rigid PVC conduit ISI marked medium grade not less than 20 mm dia, with MS stove enamelled sunken boxes (normal and modular type as required) including earth dolly with plastic laminated sheet top cover (cover plate with frame in case of modular) of approved make and colour including 1.5 sqmm multi stranded FRLS copper conductor cable of green colour as continuous earth wire with lugs and accesseries and making good disturbed surfaces of walls/floor etc complete all as specified and directed for the followings :-
One light / fan point controlled by one way switch
One 5 Amp socket outlet on independent board.
One 5 Amp socket outlet on same board.
One bell/buzzer point controlled by one bell push
One light point controlled by two 2-way switch
All as per above item No-2 here in before but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed, FRLS cable for 15 Amp socket outlet on independent board including 2.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs etc as required complete all as specified and as directed.
M&L for replacement of point wiring in casing caping on sufraces of wall/ceiling floor etc complete with PVC insulated and unsheathed FRLS cable of 1.5 sqmm (nominal area) with multi stranded copper conductor single core 1100 volts grade with PVC rectangular block of suitable size including 1.5 sqmm multi stranded FRLS copper conductor cable of green colour as continuous earth wire with lugs and accesseries and making good disturbed surfaces of walls/floor etc complete all as specified and as directed for the followings :-
One light / fan point controlled by one way switch
One 5 Amps socket out let point controlled by one 1-way switch on independent board.
One 5 Amps socket out let point controlled by one 1-way switch on same board.
One bell/buzzer point controlled by one bell push
One light point controlled by two 2-way switch
All as per above item no 112 here in befor but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed, FRLS cable for 15 Amp socket outlet on independent board including 2.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs etc as required complete all as specified and as directed.
M & L for replacement of existing conduit point wiring complete with PVC insulated and unsheathed FRLS cable of 1.5 sqmm (nominal area) with multi stranded copper conductor single core 1100 volts grade drawn through existing conduitwith MS stove enamelled sunken boxes (normal and modular type as required) including earth dolly with plastic laminated sheet top cover ( cover plate with frame in case of modular) of approved make and colour including 1.5 sqmm multi stranded FRLS copper conductor cable of green colour as continuous earth wire with lugs and accesseries and making good disturbed surfaces of walls/floor etc complete all as specified and directed for the followings :-
One light / fan point controlled by one switch.
One bell point controlled by one bell Push
One 5 Amps socket out let point controlled by one switch on independent board.
One 5 Amps socket out let point controlled by one switch on same board.
All as per item No. 114 but with 2.5 Sqmm nominal cross sectional area electric cable for 15 Amps socket outlet point controlled by one switch on independent board complete.
S&F in replacement switch piano type 5 amp one way 240 volts AC 50 hz ISI Marked complete all as specified and directed by Engineer-in-Charge.
S&F in replacement switch piano type15 Amps one way 240 volts AC 50 hz ISI Marked complete all as specified and directed by Engineer-in-Charge.
S&F in replacement socket outlet 5 pin 5 Amps 240 volts AC 50 hz ISI marked flush type complete all as specified and directed by Engineer-in-Charge.
S&F in replacement socket outlet 2-in-1, 6 pin 5 amp and 15 amps 240 volts AC 50 hz ISI marked all as specified and directed.
S&F in replacement socket outlet 6A-2/3 Pin combined 2 module 240 volts AC 50 hz ISI marked modular type complete all as specified and directed.
S&F in replacement socket outlet 6A/16A-2/3 pin combined 2 module 240 volts AC 50 hz ISI marked modular type complete all as specified and directed.
S&F in replacement switch 6 amps modular type one one way 240 volts AC 50 hz ISI marked complete all as directed.
S&F in replacement switch 16 amps modular type one one way 240 volts AC 50 hz marked complete all as directed.
S&F in replacement electronic fan regulator Step type complete all as specified and directed.
S&F in replacement bell push flush type 5 amp one way 240 volts AC 50 hz ISI Marked complete all as specified and directed.
S&F in replacement modular type bell push 6 amp one module 240 volt ISI marked complete all as specified and directed.
S&F in replacement Bell, DING DONG AC 230 Volts single pole type complete all as specified and as directed.
S & F in replacement of Lamp holder bakalite type with back plate suitable for batten fittings complete all as specified as directed
S&F in replacement of ceiling rose surface bakelite 63 x50mm three terminals complete all as specified and as directed.
S & F in replacement of sub main wiring with PVC insulated, FRLS unsheathed two single core cable 1100 volts grade with stranded copper conductor of size 4.0 sqmm (Nominal area) drawn in and including PVC conduit of suitable size as directed with and including one run of 4.0 sqmm multi stranded copper conductor single core PVC insulated, unsheathed cable of green colour as continuous earth wire including lugs etc connected and tested complete all as specified and as directed. Note: (i) Two runs of 4.0 sqmm cable and one run of 4.0 sqmm cable of earth continuity conductor and conduit shall be a unit length.
S & F in replacement of sub main wiring with PVC insulated, FRLS, unsheathed two single core cable 1100 volts grade with stranded copper conductor of size 6.0 sqmm (Nominal area) drawn in and including PVC conduit of suitable size as directed with and including one run of 6.0 sqmm multi stranded copper conductor single core PVC insulated, unsheathed cable of green colour as continuous earth wire including lugs etc connected and tested complete all as specified and as directed. Note: (i) Two runs of 6.0 sqmm cable and one run of 6.0 sqmm cable of earth continuity conductor and conduit shall be a unit length. Common Note For Item No- 36 & 37- (i) if the contractor fail to make good the disturbed surface of wall and do not match with existing surface of wall to the entire satisfaction of Engr-in-Charge a recovery of Rs 50 per RM shall be made from payment due to contractor.
S & F in replacement of Regid non-metallic PVC conduit 25 mm (external dia) ISI marked (on surface) incl of all accessories and all fittings such as Tees bends, elbows, reducers, bell mouth, tube ends and fixing accossories such as couplers lock nuts, saddles, pipe hook etc complete all as specified and as directed.
S&F in replacement of single pole and neutral enclosure with 2 pin and metal earth plug and socket complete with one single pole MCB 25 Amp complete all as specified and as directed.Make-Havells/Indoasian/Legrand
S&F in replacement of Double door prewired distribution board 4 way TPN when MCB to be used as incomer powder coated with Bus Bar 200 Amps, 415 V, Earth Stud, Din Rail, complete all as specified and directed (Note- (a) MCBs are to be measured and paid seperately. (b)Make of MCBs and DB should be same.) Make-Havells/Indoasian/Legrand.
S&F in replacement MCB SP 6 to 32 Amps, 240 volts curve 'B',breaking capacity 10KA, all as specified.
S&F in replacement MCB SPN 16 to 40 Amps, 240 volts, curve 'B', breaking capacity 10 KA, all as specified.
S&F in replacement MCB SPN 40 to 63 Amps, 240 volts, curve 'C', breaking capacity 10 KA, all as specified.
S&F in replacement MCB TPN 40 to 100 Amps, 415 volts, curve 'B', breaking capacity 10 KA, all as specified.
S&F in replacement MCCB , 125 Amps, 4Pole with adjustable thermal magnetic release type setting knob and rupturing capacity 16 kA complete all as specified and directed.
S & F In replacement of modular switch 2 way, 6 Amp,1 module ISI Marked complete all as specified and as directed.
S & F in replacement of modular Fan Regulator fan step regulator,120W- single module ISI Marked complete all as specified as as directed.
S & F In replacement of Piano type switch 2 way, 5 Amp,1 module ISI Marked complete all as specified and as directed.
S&F in modular blanking plate, 1 module ISI Marked complete all as specified and as directed.
S&F in replacement metal flush box 3 module all as specified and directed.
S&F in replacement metal flush box 6 module all as specified and directed.
S&F in replacement metal flush box 8 module all as specified and directed.
S&F in replacement for white cover plate with frame, 3 module all as specified and directed.
S&F in replacement for white cover plate with frame, 6 module all as specified and directed.
S&F in replacement for white cover plate with frame, 8 module all as specified and directed.
M & L in repair for Earth continuity conductor or main earthing lead of 4.0 Sqmm galvanized iron wire, buried in ground or fixed to wall in and including 15 mm bore GI pipe medium grade for protection of earth wire complete all as specified and directed.
S&F in replacement enviroment friendly,ultra modern,energy saving surface mounted decorative 12 Watt LED bulkhead fitting PC housing ,high efficient LEDs with opal diffuser and IP65 protectio, lumen efficacy 85 lm/watt with colour temerature 3500K/6500K as per site requirement, THD≤ 20 CRI>80,2.5 kV surge protection all as specified and directed. Make- Surya/crompton/Jaquar
S&F 09 watt LED bulb with B22 Base cap, 1200 lumens ,Colour rating Index 80,colour temp F 6500K,satrtup time less than 2 sec,In built surge 3.0 kV, voltage range 140V to 270 V , Lamp life 15000 hours complete all as specified and directed.
S&F 12 watt LED bulb with B22 Base cap, 1200 lumens ,Colour rating Index 80,colour temp F 6500K,satrtup time less than 2 sec,In built surge 3.0 kV, voltage range 140V to 270 V , Lamp life 15000 hours complete all as specified and directed.
S&F in replacement of enviroment friendly indoor decorative 20 Watt LED polycarbonate Batten with opal diffuser , operating voltage range 140v to 270 V, Driver efficiency 88%, lumen efficiency =100 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 2.5 Kv, isolation=3.75, and with zero mercury content including all accessaries all as specified and directed. Make- Surya/crompton/Jaquar
S&F in replacement of enviroment friendly indoor decorative 9/10 Watt LED polycarbonate Batten with opal diffuser , operating voltage range 140v to 270 V, Driver efficiency 88%, lumen efficiency =100 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 2.5 Kv, isolation=3.75, and with zero mercury content including all accessaries all as specified and directed. Make- Surya/crompton/Jaquar
S & F in replacement enviroment friendly recess/pendent/Surface mounting as required at site 36 watt LED flat panel 2'x2' fabricated CRCA sheet steel duly powder coated housing cool white with high efficient LEDs & glare free opal diffuser PF>0.95 , lumen efficacy>100 lm/W, THD<10% operating range 220v to 240V,CRI>80 including connection with existing wire and all accessaries all as specified and directed. Make- Surya/Halonix/orient
S & F in replacement enviroment friendly recess/pendent/Surface mounting 24 watt LED flat panel 1'x1' fabricated CRCA sheet steel duly powder coated housing cool white with high efficient LEDs & glare free opal diffuser PF>0.95 , lumen efficacy>100 lm/W, THD<10% operating range 220v to 240V,CRI>80 including connection with existing wire and all accessaries all as specified and directed. Make- Surya/Halonix/orient
S&F in replacement of enviroment friendly indoor decorative 5/6 Watt LED polycarbonate Batten with opal diffuser , operating voltage range 140v to 270 V, Driver efficiency 88%, lumen efficiency =100 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 2.5 Kv, isolation=3.75, and with zero mercury content including all accessaries all as specified and directed. Make- Surya/Halonix/orient
S & F in repair plastic laminated bakelite sheet cover of Hylam brand including cutting holes for switches, sockets etc as pre requirement including fixing with machine screws and washer complete of following sizes:-
(a) 10" x 12" size
(b) 8" x 10" size
(c) 8" x 6" size
(d) 7" x 4" size
(e) 4" x 4" size
S&F in replacement of Energy meter Box Flame retardent polycarbonate body including all fixing arrangement like DIN rails mounting plate connection boxes fastning screw protection plate extra suitable to accomodate single Phase/three phase energy meter with locking arragement as per site rwquirement complete all as specified and directed.
M&L for flame proof wiring with single core PVC insulated and unsheathed 1100 volt grade FRLS electric cable with multi stranded copper conductor of size 2.5 Sqmm phase and neutral drawn in and including ERW rigid steel stove enameled black conduit heavy duty ISI marked of size 20mm dia on surface/wall/ceiling including all flame proof conduct fittings and accessories such as tees junction boxes, bends duly tested by CMRI Dhanbad suitable for one light /fan point controlled by one flame proof rotary switch SP one way and including drawing continuous earth wire FRLS PVC insulated unsheathed 1100v grade cable with stranded copper conductor of size 1.5 Sqmm and connected to earth dolly complete all as specified and directed by Engrs-in-Charge.
Supply and fixing flame proof/weather proof direct entry type rotary switch single pole on & OFF rotary motion switch in cast aluminum alloy LM-6 enclosure epoxy powder coated single pole 230Volts 10 Amps, AC ON/OFF switch operated externally by Knob having 02 Nos of M-20 cable entries, earthing terminals suitable for mounting on Wall/Steel structure etc all as specified and directed. Make : Flexpro/Sudhir/Baliga/Shyam.
Supply and fixing LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver,holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and as directed size. Note :- (a) All fittings shall be ISI marked and shall have approval of CMRI Dhanbad . (b) Original Test certificate of Manufacturer shall be produced by Contractor .
M&L for fixing PVC gang box for mounting one switch and one socket of 5 Amps including all accessoriese complete all as specifies and directed.
M&L for fixing PVC gang box for mounting one switch and one socket of 15 Amps including all accessoriese complete all as specifies and directed.
Supply and fixing of PVC Casing capping 20/25mm ISI marked all as specified and as directed by Engineer-in-charge.
S&F in replacement of Cable PVC insulated unsheathed single core 1100V FRLS grade stranded flexible copper conductor of size 1.5 sqmm complete all as specified and directed. Make:- Finolex/Havells/Grandlay
Supply and fixing in replacement of Cable PVC insulated unsheathed single core 1100V FRLS grade stranded flexible copper conductor of size 2.5 sqmm complete all as specified and directed. Make:- Finolex/Havells/Grandlay
Supply and fixing in replacement of Cable PVC insulated unsheathed twin core of 23/0.0076 size flexible copper conductor complete all as specified and directed.
Supply and fixing in replacement of Cable PVC insulated unarmoured three core 1100V FRLS grade stranded flexible copper conductor of size 2.5 sqmm complete all as specified and directed. Make:- Finolex/Havells/Grandlay
Supply and fixing 25 mtr long 2.5 cm wide and atleast .125 mm wall thickness self adhesive PVC insulated electrical tape roll of good quality complete all as specified and directed.
Supply and fixing of PVC round shape junction box cover of suitable size including fcomplete all as specified and as directed.
Taking down light fittings of any type any size any location complete all as specifed and directed.
Taking down DB including old U/s MCB/MCCB of any size any type from any location complete all as specifed and directed.
S&F in replacement of recesses/surface mounted square/round shape slim downlighter of 12 watt capacity with colour temperature 3500/6500 K as required, Lumens 780, CRI more than 80 including all accessories and ring for mountiong on ceiling complete all as specified and directed.Make- orient, Philips, Halonix
S&F in replacement of old unserviceable decorative type wall mounted with new wall comet light fitting with LED bulb pin type B22 cap 3500 K complete all as specified and directed. Make- Philips 30575 or equivalent
Supply & Fix in replacement of copper wound Fan motor for exhaust Fan upto 300mm sweep metal body any sweep complete as per matching to existing type and gauge cpmplete all as specified and directed.
Supply & Fix in replacement of copper wound Fan motor for Ventilating Fan PVC body 250/200 mm sweep with front lock & capacitor complete as per existing model and gauge complete all as specified and directed.
Supply & fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed by Engr-in-Charge. Make- Orient/Crompton/Havells
Supply & fixing exhaust fan, steel body AC single Phase. 230V of size 300 mm sweep double bearing with, 1400 RPM, blades, and frame and louver complete all as specified and as directed by Engr-in-Charge. Make- Orient/Crompton/Havells
Supply & fixing wall mounting fans 230 volts single phase oscillating 400 mm sweep suitable for wall mounting complete all as specified and as directed by Engr-in-Charge. Make- Orient/Crompton/Bajaj
supply & fixing plastic body ventilation fan 250 mm as required 50 Hz , 240 volt 1250 RPM with copper wound motor including all fixing accessories complete all as specified and directed.Make- Orient/Crompton/Havells
Supply and fixing in replacement post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 class protection with aluminium die cast housing cum heat sink circular canopy and clear acrylic cover for 360 degree indirect uniform glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total system lumen not less than 3200 lumens lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 3500/ 6500 K as required, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours including grouting in post by using suitable dia mediun grade GI pipe complete all as specified and directed..
supply and fixing plastic body ventilation fan 200 mm as required 50 Hz , 240 volt 1250 RPM with copper wound motor including all fixing accessories complete all as specified and directed.Make- Orient/Crompton/Havells
Supply and fix electric water heater, storage type with SS tank and outer body made out of ABS & PP, heating element of 2 KW storage capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, SS connection piece of suitable length etc complete all as specified and as directed by Engr-in-Charge. Make:- Racold/Havells/Crompton
S & F in replacement of sub main wiring with PVC insulated, FRLS unsheathed two single core cable 1100 volts grade with stranded copper conductor of size 10.0 sqmm (Nominal area) drawn in and including PVC conduit of suitable size as directed with and including one run of 10.0 sqmm multi stranded copper conductor single core PVC insulated, unsheathed cable of green colour as continuous earth wire including lugs etc connected and tested complete all as specified and as directed. Note:(i) Two runs of 10.0 sqmm cable and one run of 10.0 sqmm cable of earth continuity conductor and conduit shall be a unit length.
S & F in replacement of sub main wiring with PVC insulated, FRLS unsheathed two single core cable 1100 volts grade with stranded copper conductor of size 2.5 sqmm (Nominal area) drawn in and including PVC conduit of suitable size as directed with and including one run of 2.5 sqmm multi stranded copper conductor single core PVC insulated, unsheathed cable of green colour as continuous earth wire including lugs etc connected and tested complete all as specified and as directed. Note: (i) Two runs of 2.5sqmm cable and one run of 2.5 sqmm cable of earth continuity conductor and conduit shall be a unit length.
S & F in replacement of sub main wiring with PVC insulated, FRLS unsheathed two single core cable 1100 volts grade with stranded copper conductor of size 1.5 sqmm (Nominal area) drawn in and including PVC conduit of suitable size as directed with and including one run of 1.5 sqmm multi stranded copper conductor single core PVC insulated, unsheathed cable of green colour as continuous earth wire including lugs etc connected and tested complete all as specified and as directed. Note: (i) Two runs of 1.5 sqmm cable and one run of 1.5 sqmm cable of earth continuity conductor and conduit shall be a unit length.
S&F of Flameproof cum Waterproof LED Bulk Head light fitting of 70W, IP66 protection of Cast Aluminum alloy material and Heat and Impact resistance toughen 'A' clear glass having Anti corrosive epoxy powder coated finish complete with all accessories pre wired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and as directed.
S&F in replacement metal flush box 4 module all as specified and directed.
S&F in replacement for white cover plate with frame, 4 module all as specified and directed.
S&F in replacement metal flush box 12 module all as specified and directed.
S&F in replacement for white cover plate with frame, 12 module all as specified and directed.
S&F in replacement of enviroment friendly indoor decorative three in one 20 Watt LED polycarbonate Batten with opal diffuser , operating voltage range 140v to 270 V, Driver efficiency 88%, lumen efficiency =100 lm/watt , THD≤ 20 CRI>80 , three in one colour temperature (6500k/4000K/3500 K) operated by single switch, inbuilt surge protection = 2.5 Kv, isolation=3.75, and with zero mercury content including all accessaries all as specified and directed.
shiv shanker enterprises (BID ID -3517590)
Shiv Shakti Builders (BID ID -3517259)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.16 MB
BOQ_832743.xls
BOQ • 0.44 MB
TenderDocuments102.pdf
Tender Documents • 0.63 MB
Download all tender documents and submit your bid