Chief Engineer M and H Jaipur
Chief Engineer M and H Jaipur
SITC OF HVAC SYSTEM WORK FOR CONSTRUCTION OF DISTRICT HOSPITAL IN SALUMBER, RAJASTHAN
2025_MEDIC_479940_1
NIT No 10/2025-26 CHIEF ENGINEER MEDICAL AND HEALTH JAIPUR
Open Tender
Electrical Works
Percentage
120 days
SALUMBER
Please refer Tender documents.
3 documents required · 3 mandatory
₹2,000
RTGS-NEFT TO HDFC BANK AC 50100255592722
₹6.9 L
28 Jul 2025
16 Jun 2025
8 Jul 2025
16 Jun 2025
7 Jul 2025
16 Jun 2025
Amount
ITEM (Non-BSR)
Supply, Installation, testing and commissioning of factory fabricated double skin type Air Handling Unit as per specifications given below:-
AHU Construction:- The casing shall be self-supporting type, factory fabricated & assembled made of extruded anodised aluminium hollow sections to make a rigid frame structure. The frame shall be assembled using pressure die cast aluminium joints. The self-supporting unit shall consist of sandwiched panel made out of 0.8 mm thick pre-plasticised / pre-coated GI sheet outside & 0.6 mm polished stainless steel inside duly factory fabricated insulated with 43 mm thick PUF insulation in between as specified. The Entire housing shall be mounted on Extruded Aluminium channel framework having pressure die cast aluminium jointers or the framework shall be joined together with corner plates Condensate. Drain Pan shall be constructed of 1.25 mm Stainless steel sheet with 19 mm closed cell insulation (nitrile rubber / xlpe) with all corners welded with uniform slope from all sides leading to drain pan ensuring no stagnation of condensate water.
Fan & Motor:-Plug type centrifugal fan (with Min. 75 % efficiency) with blower motor, drive and flexible duct connection.The fan motors shall be suitable for 415 ± 10% volts, 50 ± 5 % HZ, 3 phases TEFC SQ. Cage induction motor. The motor shall be specially designed for quiet operation & motor speed shall not exceed 1440 RPM (IE3).
Coil Section- The cooling & heating coil shall be made of aluminium fins and copper tubes of dia.12.5mm or 16mm OD. The minimum no. of fins / cm for cooling coils shall be 4.7 & for heating coil it shall be 2.4. The bonding of aluminium fins with copper should be done hydraulically. The tube thickness shall be 26 G & fin thickness shall be 37 G. The cooling / heating coil should be tested for leaks at a hydraulic pressure of at least 10 Kg / sq.cm. for a minimum period of 3 hours at works. The velocity across face should be limited to 152 metre / minute. Coil shall be designed for following parameters: Chilled Water IN / OUT ‐ 44 °F/ 54 °F
Pre Filter Section:- Cleanable metallic viscous type filter made out of aluminium wire mesh or of dry cleanable synthetic type minimum 50mm thick, shall be provided on the suction side of AHU as a standard equipment with the unit. These filters shall have the efficiency of 90% down to 10 micron particle size. When these filters become loaded or full of dirt, it is removed from service and replaced by another filter. The dirty filter can then be washed in a cleaning solution in a tank, dried and then given a bath of viscous oil. Face velocity across these filters shall not exceed 155 MPM.
Fine/microvee Filter Section:- These filters shall have efficiency of 99% down to 3 micron particle size as per EU standard. Face velocity across these filters shall not exceed 155 MPM.
Accessories:- Fan should be complete with all accessories including flexible fire rated canvas connection for duct connection,drain valve ,auto airvent valve,descaling valve, not return damper etc. as specified in the specification.
Note:- AHU shall be complete with Discharge plenum section & Mixing Box comprising of damper. AHU to be provided with Standby motor and drive set. FM AHU having Prefilter section and Fine/microvee section, 6rows deep DX cooling coil, and discharge plenum, 120mmwg static pressure.
2400 CFM (6.0 TR ) ESP - 120 mm FOR 1st FLOOR OT
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.25 MB
SITC-HVAC-Salumber.pdf
Tender Documents • 11.67 MB
BOQ_857620.xls
BOQ • 0.42 MB
BOQ.xls
BOQ • 0.42 MB
Tenderdocument.pdf
Tender Documents • 11.67 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .