| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹98.8 LAccepted-AOC SHOP NO 5 BACHAT BHAWAN UNA TEHSIL UNA HP 174303 | UNA | UNA | HP | 174303 | L-1 | Accepted-AOC AOC done | |
| 2 | L-2₹1.1 Cr+₹85,092 (0.77%)Rejected-Finance | L-2 | Rejected-Finance Un-Responsive | |
| 3 | Rejected-Technical | - | Rejected-Technical Un-Responsiv | |
| 4 | Rejected-Technical VILLAGE DINAK P O KANAID TEHSIL SUNDERNAGAR | BILASPUR | HIMACHAL PRADESH | 174001 | - | Rejected-Technical Un-Responsiv | |
| 5 | Rejected-Technical | - | Rejected-Technical Un-Responsiv |
Tender Value
Refer Docs
EMD Value
₹1.1 L
Closing Date
10 Dec 2020, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer Electrical Division HPPWD Una
Executive Engineer Electrical Division HPPWD Una
Construction of Mini Sectt. building at Una Distt Una H.P. SH Providing E.I.there in .
2020_PWD_42757_1
PW-EDU-CB-TA-Tender-2020-21- 2805-10 Dt-16-11-2020
Open Tender
Electrical Works
Item Rate
730 days
Una
Please refer tender document
6 documents required · 6 mandatory
₹2,000
EE Electrical
₹1.1 L
8 Oct 2022
25 Nov 2020
11 Dec 2020
25 Nov 2020
10 Dec 2020
25 Nov 2020
120 days
Amount
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit with modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required.Make:- Legrand(Myrius.L&T (Oris)Anchor (Roma plus)
Group C.
Wiring for twin control light point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit with 2-way, 5/6 amps. modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required.Make:- Legrand(Myrius.L&T (Oris)Anchor (Roma plus)
Group C.
Wiring for power plug with 2x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.(Finolex/KEI/Anchor/L&T make)
Wiring for power plug with 4x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.(Finolex/KEI/Anchor/L&T make)
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required.(KEI/Anchor/L&T make)
2x1.5 Sq. mm.
2x2.5 Sq. mm.
2x6.0 Sq. mm.
2x10 Sq. mm.
Wiring for circuit/sub-main with 4x2.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.2.5 Sq.mm.(4X2.5+2X2.5) HRFRLS/PVC insulated single core copper conductor cable for earthing as required.(KEI/Anchor/L&T make)
Wiring for circuit / sub-main with 4x6 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.6 Sq.mm. (4x6+2x6) HRFRLS/PVC insulated single core copper conductor cable for earthing as required.(KEI/Anchor/L&T make)
Wiring for circuit / sub-main with 4x10 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.10 Sq.mm. (4x10+2x10) HRFRLS/PVC insulated single core copper conductor cable for earthing as required.(KEI/Anchor/L&T make)
Supplying and drawing following size of PVC insulated, heat resistant, flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in existing surface / recessed, Steel/PVC conduit as required.(KEI/Anchor/L&T make)
3x1.5 Sq. mm.
6x1.5 Sq. mm.
Supplying and fixing of following sizes of PVC conduit along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required:-(Diplast/Polycab make)
25 mm. dia
Supplying and fixing following rating Modular switch /socket in the existing switch box / cover plate including connections etc. as required.Make:- Legrand(Myrius.L&T (Oris)Anchor (Roma plus)
S.P. 5/ 6 Amps one way Modular switch.
5 pin, 5/ 6 Amps Modular socket outlet.
Supplying and fixing stepped type Modular fan regulator on the existing modular box including making connections etc. as required. Make:- Legrand(Myrius.L&T (Oris)Anchor (Roma plus)
Supplying & fixing Modular blanking plate on the existing modular metal box as required:-Make:- Legrand(Myrius.L&T (Oris)Anchor (Roma plus)
Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 5 pin 5/6 amps modular socket outlet and 5/6 amps, modular switch, connections etc. as required.Make:- Legrand(Myrius.L&T (Oris)Anchor (Roma plus)
Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps, modular switch, connections etc. as required.Make:- Legrand(Myrius.L&T (Oris)Anchor (Roma plus)
Supplying and fixing bakelite batten/angle holder including connections etc. as required:- (SSK/Anchor make)
Supplying and fixing call bell / buzzer, suitable for D.C./A.C. single phase,230 volts complete as required:- (SSK/Anchor make)
Supplying and fixing Ding-Dong / Electronic musical bell, suitable for D.C./A.C. single phase,230 volts complete as required:-(SSK/Anchor make)
Supplying and erection of wall mounted metal boards for switch gear mounting of suitable size, with permissible variation in size of plus minus 5mm, welded frame work made of M.S. angle iron 35 mm x 35 mm x 6 mm thick duly welded complete with 2.80mm thick M.S. sheet fixed with hinges as open able front, complete with locking arrangement including painting and bonding to the existing earth as required:-
Supplying and erection of following depth sheet metal cubical pedestal of suitable dimensions with plus-minus 5 cm variation made from (50 mm x 50 mm x 6 mm thick) M.S. angle iron frame, covered with 1.6 mm thick M.S. sheet duly welded on five sides & front side hinged, complete with locking arrangement with sufficient No. vertical and horizontal intermediate switchgear supporting members each of M.S. flat 50mmx6mm thick of suitable length duly welded. The cubical pedestal shall have cable entry box at one or two sides and 4 No. legs of 50mmx50mmx6mm thick M.S. angle iron each 60 cm long including, powder coated painting and bonding to the existing earth etc., the same shall be erected in the 1:2:4 cement concrete plat-form of suitable dimensions 15 cm high from ground level and 45 cm thick. The cubical pedestal shall be 15 cm from the top of cement concrete plat-form:-(EVA,Power & Control System,Supettech make or its equivalent approved make)The panel should be approved /tested from the PRI Labs & should be confirmed to IS:64139
300 mm deep (nominal)
Supplying and fixing sheet metal bus-bar chamber suitable for 63 Amp. 415 volts capacity with 4 No. copper strip bus-bars each of length 300mm & cross-sectional area (16mmx3.17mm), enclosure made from 1.6 mm thick M.S. sheet having overall dimensions (380mmx350mmx150mm) nominal with all accessories including connections, earthing the body etc. as required:-(Legrand/Schneider/Siemens make)
Supplying and fixing sheet metal bus-bar chamber suitable for 100 Amp. 415 volts capacity with 4 No. copper strip bus-bars each of length 300mm & cross-sectional area (25.4mmx3.17mm), enclosure made from 1.6 mm thick M.S. sheet having overall dimensions (380mmx400mmx150mm) nominal with all accessories including connections, earthing the body etc. as required:-(Legrand/Schneider/Siemens make)
Supplying and fixing sheet metal bus-bar chamber suitable for 200 Amp. 415 volts capacity with 4 No. copper strip bus-bars each of length 300mm & cross-sectional area (25.4mmx4.75mm), enclosure made from 1.6 mm thick M.S. sheet having overall dimensions (380mmx450mmx150mm) nominal with all accessories including connections, earthing the body etc. as required:-(Legrand/Schneider/Siemens make)
Supplying and fixing copper strip bus-bars suitable for 63 Amp. 415 volts capacity 4 No. each of cross-sectional area (16mmx3.17mm),in the existing enclosure with all accessories including connections etc. as required:-
Supplying and fixing copper strip bus-bars suitable for 100 Amp. 415 volts capacity 4 No. each of cross-sectional area (25.4mmx3.17mm),in the existing enclosure with all accessories including connections etc. as required:-
Supplying and fixing copper strip bus-bars suitable for 200 Amp. 415 volts capacity 4 No. each of cross-sectional area (25.4mmx4.75mm),in the existing enclosure with all accessories including connections etc. as required:-
Supplying and fixing copper strip bus-bars suitable for 300 Amp. 415 volts capacity 4 No. each of cross-sectional area (31.75mmx6.35mm),in the existing enclosure with all accessories including connections etc. as required:-
Supplying and fixing copper strip bus-bars suitable for 400 Amp. 415 volts capacity 4 No. each of cross-sectional area (38.10mmx6.35mm),in the existing enclosure with all accessories including connections etc. as required:-
Supplying and fixing copper strip bus-bars suitable for 1000 Amp. 415 volts capacity 4 No. each of cross-sectional area (50.80mmx12.70mm),in the existing enclosure with all accessories including connections etc. as required:-
Providing and fixing following rating, four pole, 415 volts, On-Load change over switch unit, panel mounting, front handle operation, including drilling holes in the cubical, making connections, etc. as required.(L&T/ABB/Siemens make)
Providing and fixing following rating and breaking capacity MCCB in the existing cubical panel board including drilling holes in the cubicle panel, making connections, etc. as required.(L&T/ABB/Siemens make)
100 Amp. -10 KA
125 Amp. -16 KA
160 Amp. -16 KA
200 Amp. -25 KA
315/400 Amp. -35 KA
Providing and fixing following rating, three pole, manually operated, draw-out type, air circuit breaker, microprocessor based release;SR18G, open execution, in the cubicle panel, making connections, etc. as required.(L&T/ABB/Siemens make)
1000 Amp. -50 KA; C-Power
Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:- (Hagger/ABB/L&T make)
Single pole. 6 Amps.Cat-A.
Single pole. 16 Amps.Cat-A.
Single pole. 25 Amps.Cat-A.
Supplying and erection of 40/50/63 amps rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:-(Hagger/ABB/L&T make)
Double pole. 40 Amps.Cat-A.
Double pole. 63 Amps.Cat-A.
Supplying and fixing following rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Hagger/ABB/L&T make)
40 Amps. Cat-A.
63 Amps. Cat-A.
Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:- (Hagger/ABB/L&T make)
Single door-8 way
Single door-12 way
Single door-16 way
Double door-8 way
Double door-12 way
Double door-16 way
Earthing with copper earth plate 600 mmx600 mmx 3 mm thick, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required.
Extra for using salt and charcoal for G.I. or copper plate earth electrode complete as required.
Providing and fixing 25mm x 5mm copper strip on surface or in recess for earth connections etc. as required.
Providing and fixing of lightning conductor finial, made of 25 mm dia. 300 mm long copper tube, having single prong at top, with 85 mm dia 3 mm thick copper base plate including holes etc. complete as required.
Riveting, sweating and soldering of copper/ G.I. tape ( with another copper/G.I. tape, base of the finial or any other metallic object) as required.
Supplying and fixing copper tape 20mmx3mm thick on parapet or surface of wall for lightning conductor as required ( for vertical run)
Supplying and fixing copper tape 20mmx3mm thick on parapet or surface of wall for lightning conductor as required ( for horizontal run)
Providing and fixing H.T.danger notice plate of 250mm x 200mm made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides and with inscription in signal red color on front side as required.
Providing, laying and fixing of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade on surface etc. of the required size:-(Havells/KEI/L&T or its equivalent make)
Armoured cable 10 sq. mm (Four core)
Armoured cable 16 sq. mm (Four core)
Armoured cable 35 sq. mm (3.5 core)
Armoured cable 50 sq. mm (3.5 core)
TERM AND CONDITIONS :-1. Conduit pipe is to be laid simultaneously with the progress of civil work.2. No part rates for any single items in Schedule of quantity will be accepted and the tender will be accordingly rejected.3. The Electricity items/fixture of any other material for which absurd low rates are quoted by the Contractor will have to be supplied in first instance.4. Test certificate along with bill for the items demanded by the department will have to supplied before installation.
Rajesh Kumar Jaswal
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .