Loading…
Loading…
| # | Company |
|---|---|
| 1 | 3 CORRIGENDUM ADDENDUM 02 DATED 01 01 2022 4 CORRIGENDUM ADDENDUM 03 DATED 03 01 2022 5 CORRIGENDUM ADDENDUM 04 DATED 07 01 2022 6 YOUR TENDER SUBMITTED ON 14 01 2022 ON E TENDER WEBSITE 7 YOUR PRICE BID OPENED ON 29 01 2022 ON E TENDER WEBSITE |
Tender Value
₹23.5 Cr
EMD Value
₹23.5 L
Closing Date
17 Oct 2023, 11:00 amClosed
Construction of balance internal work of Library Building at Chaudhary Ranbir Singh University Jind Haryana at the Risk and Cost of Ms R and B Infra
NBCC/RBG/UUDN/CRSU/2023/48
NBCC/RBG/UUDN/CRSU/2023/48
Open Tender-Domestic
Civil Works - Buildings
Jind, Haryana
₹11,800
₹23.5 L
1 Aug 2026
7 Oct 2023
17 Oct 2023
17 Oct 2023
19 Oct 2023
ESTIMATED COST PUT TO TENDER
Original BOQ Items Balanced BOQ to be executed at Risk & Cost
H.S.R./DSR ITEMS
Sr. No. DESCRIPTION OF WORK H.S.R./DSR ITEMS
(WITH DISCOUNT NON-SCHEDULE REMAINING NON- TOTAL REMAINING
FACTOR ON DSR- ITEMS SCHEDULE ITEMS AMOUNT Rs.
PROVISION FOR LOW VOLTAGE
16 LIBRARY INFORMATION DISPLAY 0.00 7,68,778.07 0.00 7,68,778.07 7,68,778.07
Estimated Cost Put to Tender 23,48,90,156.97
Digitally signed by RAHUL
Construction of balance internal work of Library Building at Chaudhary Ranbir Singh University, Jind, Haryana at the Risk and Cost of M/s. R and B Infra Project Pvt. Ltd.
BOQ For "Construction of balance internal work of Library Building at Chaudhary Ranbir Singh University, Jind, Haryana at the Risk
and Cost of M/s. R and B Infra Project Pvt. Ltd."
Total Balance Qty. to Rate at which
Quantity be executed at item was
Description of Item Unit in Original Risk & Cost Awarded in
Tender original tender
(1). CIVIL WORKS BELOW PLINTH LEVEL
HSR Earth work in excavation in ordinary soil exclusive of compensation of earth work undressed
6.2 (b) with a combined lead upto 15 Metres including breaking of clods complete in all respects.
Disposal of surplus earth excavated from basement & foundation from the building,
2 loading, unloading & carriage upto any lead within the campus of University Complete in all Cum 14,656.85 2,197.23 48.00 1,05,460.15
Earth Filling under floors with surplus soil excavated from foundation and taken only from
3 outside the building plinth, in 15 cm layers including ramming watering and consolidating lead Cum 8,377.55 1,310.22 17.03 22,314.00
up to 30 meters. Subject to condition soil Is non plastic.
HSR Centring and shuttering for faces of walls,partitions, retaining Walls, well steining and
9.5 the like (vertical or battering) including attached pilasters, buttresses etc.
5 Centring and shuttering for columns (square or rectangular or Polygonal in plan). Sqm 62.35 17.80 261.22 4,650.23
6 Centring and shuttering for columns (circular or curved in plan). Sqm 45.61 - 334.91 -
7 Shuttering for faces of concrete foundations and foundations beams (vertical or battering) Sqm 2,112.65 554.50 161.91 89,777.68
8 Cement concrete 1 : 5 : 10 with brick ballast 20mm Nominal size in foundation and plinth. Cum 193.00 - 2,119.76 -
DERIVE Extra rate for using 20mm stone aggregate instead of 20mm brick ballast of nominal size
9 D in foundation and plinth. Cum 193.00 193.00 145.56 28,093.96
HSR Cement concrete 1 : 4 : 8 with stone aggregate 20 mm nominal size in foundation and
Providing & laying in position machine batched and machine mixed design mix M-35
grade cement concrete for reinforced cement concrete work, using cement content as
per approved design mix, including pumping of concrete to site of laying but excluding the
cost of centering, shuttering, finishing and reinforcement, including admixtures in
recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve
11 workability without impairing strength and durability as per direction of Engineer-in-charge in Cum 3,091.81 - 4,747.38 -
foundation and plinth.
1. Cement content considered in this item is @ 350kg/cum.).
2. In case cement content of the Design Mix is more than the minimum specified in
above items, nothing extra will be paid for extra cement to be consumed.
(II) DSR ITEMS (WITH DISCOUNT FACTOR ON DSR-2018) - - -
Authorised Signatory
Contractor BOQ Page No. 1 NBCC
Digitally signed by RAHUL
Construction of balance internal work of Library Building at Chaudhary Ranbir Singh University, Jind, Haryana at the Risk and Cost of M/s. R and B Infra Project Pvt. Ltd.
Total Balance Qty. to Rate at which
Quantity be executed at item was
Description of Item Unit in Original Risk & Cost Awarded in
Tender original tender
Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi
tracks/ runways, using cement content as per design mix, using coarse sand and graded
stone aggregate of nominal size in appropriate proportions as per approved & specified design
criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading
and compacting mechanically by using needle and surface vibrators, levelling to required
slope/ camber, finishing with required texture, including steel form work with sturdy M.S.
channel sections, curing, making provision for contraction/ expansion, construction &
12 longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and Cum 390.48 - 6,935.14 -
filling joints with approved joint filler and sealants, complete all as per direction of Engineer-in-
charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid
Note:- 1.Cement content considered in M-30 is @ 340 kg/cum.
2. In case cement content of the Design Mix is more than the minimum specified in
above items, nothing extra will be paid for extra cement to be consumed.
16.43.1 Cement concrete prepared with batch mixing machine.
Providing and laying integral cement based treatment for water proofing on the vertical
surface using Rough Kota Stone by fixing specified stone slab 22 mm to 25 mm thick with
cement slurry mixed with water proofing compound conforming to IS:2645 in recommended
DSR proportions with a gap of 20 mm (minimum) between stone slabs and the receiving surfaces
22.2.1 and filling the gaps with neat cement slurry mixed with water proofing compound and
finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20 mm
thick with neat cement punning mixed with water proofing compound in recommended
proportion complete at all levels and as directed by Engineer-in-charge.
TOTAL HSR - 2011 (WITH LATEST AMMENDMENTS) & DSR - 2018 (WITH DISCOUNTED FACTOR)
FOR : CIVIL WORK BELOW PLINTH
(III) NON SCHEDULED ITEMS - - -
Extra rate for Vaccum Dewatering of Concrete. Concrete shall be Finished with screed
14 board vibrator , vacuum dewatering process and finally finished by floating, brooming with Cum 390.48 - 209.19 -
wire brush etc. complete as per specifications and directions of Engineer-in-charge.
Providing and filling Expansion/Contraction joints ( 6mm wide ) in Pavments with
15 Polysulphide based elastic Pour Grade sealent (Make SIKA or equavalent) as approved by 9,016.00 879.90 47.54 41,832.65
Engineer in Charge as approved By Engineer in Charge.
TOTAL NON SCHEDULE ITEMS
- TOTAL RS. 41,832.65
FOR : CIVIL WORK BELOW PLINTH
(2). CIVIL WORKS ABOVE PLINTH LEVEL - - -
(I) HSR ITEMS - - -
HSR Centring and shuttering for flat surfaces such as suspended floors, Roofs,landings,
9.1 chhajjas, shelves etc. inclination not exceeding 25 degree with horizontal.
Authorised Signatory
Contractor BOQ Page No. 2 NBCC
Digitally signed by RAHUL
Construction of balance internal work of Library Building at Chaudhary Ranbir Singh University, Jind, Haryana at the Risk and Cost of M/s. R and B Infra Project Pvt. Ltd.
Total Balance Qty. to Rate at which
Quantity be executed at item was
Description of Item Unit in Original Risk & Cost Awarded in
Tender original tender
HSR Centring and shuttering for faces of walls,partitions, retaining Walls, well steining and
9.5 the like (vertical or battering) including attached pilasters, buttresses etc.
HSR Centring and shuttering for sides and soffits of beams haunchings, girders, bressumers
9.7 and lintels.
b First Storey Sqm 946.46 - 305.33 -
c Second Storey Sqm 1,215.27 - 326.46 -
d Third Storey Sqm 1,215.27 - 347.59 -
e Fourth Storey Sqm 1,215.27 - 368.72 -
4 Centring and shuttering for staircases with sloping soffits including risers and stringers. - - -
a Basment Sqm 41.99 - 268.88 -
5 Centring and shuttering for columns (square or rectangular or Polygonal in plan). - - -
d Third Storey Sqm 357.00 - 303.48 -
e Fourth Storey Sqm 357.00 - 324.61 -
Authorised Signatory
Contractor BOQ Page No. 3 NBCC
Digitally signed by RAHUL
Construction of balance internal work of Library Building at Chaudhary Ranbir Singh University, Jind, Haryana at the Risk and Cost of M/s. R and B Infra Project Pvt. Ltd.
Total Balance Qty. to Rate at which
Quantity be executed at item was
Description of Item Unit in Original Risk & Cost Awarded in
Tender original tender
6 Centring and shuttering for columns (circular or curved in plan). - - -
b First Storey Sqm 164.85 - 334.91 -
c Second Storey Sqm 164.85 - 356.04 -
d Third Storey Sqm 164.85 - 377.17 -
e Fourth Storey Sqm 164.85 - 398.30 -
HSR Centring and shuttering for corbel, parapets, fascias and other similar items, including
8 Centring and shuttering for arched roof curved slab (curvature In one direction). - - -
(Note Extra rate for Centring and Shuttering of single storey Exceeding 4.0 meters in height, for
II) every additional height of 2.0 Metres or part thereof.
For flat surfaces such as suspended floors, Roofs, landings, chhajjas, shelves etc.
inclination not exceeding 25 degree with horizontal
For faces of walls, partitions, retaining Walls, well steining and the like (vertical or
battering) including attached pilasters, buttresses etc.
c For sides and soffits of beams haunchings, girders, bressumers and lintels. Sqm 7,540.97 7,540.97 21.13 1,59,340.73
d For columns (square or rectangular or Polygonal in plan) Sqm 279.35 279.35 21.13 5,902.75
e For columns (circular or curved in plan) Sqm 109.27 109.27 21.13 2,308.92
10 Extra for smooth exposed concrete finish which is not to be touched or plastered. - - -
For flat surfaces such as suspended floors, Roofs, landings, chhajjas, shelves etc.
inclination not exceeding 25 degree with horizontal
For faces of walls, partitions, retaining Walls, well steining and the like (vertical or
battering) including attached pilasters, buttresses etc.
c For sides and soffits of beams haunchings, girders, bressumers and lintels. Sqm 406.82 406.82 137.40 55,895.53
d For staircases with sloping soffits including risers and stringers. Sqm 41.99 41.99 120.97 5,079.50
e For columns (square or rectangular or Polygonal in plan) Sqm 592.20 592.20 117.54 69,604.60
f For columns (circular or curved in plan) Sqm 311.20 311.20 150.71 46,900.73
Authorised Signatory
Contractor BOQ Page No. 4 NBCC
Digitally signed by RAHUL
Construction of balance internal work of Library Building at Chaudhary Ranbir Singh University, Jind, Haryana at the Risk and Cost of M/s. R and B Infra Project Pvt. Ltd.
Total Balance Qty. to Rate at which
Quantity be executed at item was
Description of Item Unit in Original Risk & Cost Awarded in
Tender original tender
f For corbel, parapets, fascias and other similar items, including edges. Sqm 1,288.49 1,288.49 94.13 1,21,290.44
g For arched roof curved slab (curvature In one direction) Sqm 553.67 553.67 164.39 91,017.76
HSR Cement concrete 1 : 5 : 10 with brick ballast 20 mm nominal size in first storey upto 4 Metres
10.53 above plinth level.
DERIVE Extra rate for using 20mm stone aggregate instead of 20mm brick ballast of nominal size in
12 D first storey upto 4 Metres above plinth level. Cum 907.76 907.76 145.56 1,32,137.56
Providing and laying in position machine batched and machine mixed design mix M-
35 grade cement concrete for reinforced cement concrete work, using cement content
as per approved design mix, including pumping of concrete to site of laying but excluding the
cost of centering, shuttering, finishing and reinforcement, including admixtures in
recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve
13 workability without impairing strength and durability as per direction of Engineer-in-charge in - - -
first storey upto 4 meters above plinth level.
1. Cement content considered in this item is @ 350 kg/cum.
2. In case cement content of the Design Mix is more than the minimum specified in
above items, nothing extra will be paid for extra cement to be consumed.
10 Extra rate for Cement Concrete work of single storey Exceeding 4.0 meters in height, for
(Note V) every additional height of 2.0 Metres or part thereof.
Authorised Signatory
Contractor BOQ Page No. 5 NBCC
Digitally signed by RAHUL
Construction of balance internal work of Library Building at Chaudhary Ranbir Singh University, Jind, Haryana at the Risk and Cost of M/s. R and B Infra Project Pvt. Ltd.
Total Balance Qty. to Rate at which
Quantity be executed at item was
Description of Item Unit in Original Risk & Cost Awarded in
Tender original tender
h Seventh Storey Cum 71.30 71.30 14.82 1,056.88
Cement concrete 1:1.5:3 with stone aggregate 20 mm nominal size for reinforced
15 concrete work in shelves excluding steel reinforcement but including centring and - - -
shuttering, laid in position complete in all respects.
c Second Storey Cum 0.79 0.79 6,054.22 4,805.69
e Fourth Storey Cum 0.79 0.79 6,139.06 4,873.04
h Seventh Storey Cum 0.72 0.72 6,266.31 4,486.48
HSR Cement concrete 1:1.5:3 with stone aggregate 20 mm nominal size for reinforced concrete
10.86+ work for walls exceeding 20cm thickness (straight and curved) beams, girders, stairs,
10.95 columns, (square or rectangular) battens and lintels etc. excluding steel reinforcement
(a) but including centring and shuttering, laid in position, complete in all respects.
a First Storey Cum 1.69 - 6,907.53 -
b Second Storey Cum 1.14 1.14 6,949.95 7,952.32
HSR First class brick work laid in cement sand mortar 1:6 in 1st storey upto 4 Metre above plinth
b First Storey Cum 54.00 - 3,284.00 -
c Second Storey Cum 54.00 - 3,349.37 -
d Third Storey Cum 54.00 - 3,407.21 -
18 11.48 11.43 cm thick brick wall laid in cement sand mortar 1:4 in spuer-structure. - - -
a Basment Sqm 27.55 - 436.60 -
Authorised Signatory
Contractor BOQ Page No. 6 NBCC
Digitally signed by RAHUL
Construction of balance internal work of Library Building at Chaudhary Ranbir Singh University, Jind, Haryana at the Risk and Cost of M/s. R and B Infra Project Pvt. Ltd.
Total Balance Qty. to Rate at which
Quantity be executed at item was
Description of Item Unit in Original Risk & Cost Awarded in
Tender original tender
h Seventh Storey Sqm 3.60 3.60 481.76 1,734.35
HSR Masonary Work using Flyash-lime based bricks as per (IS:12894-2002) laid in cement
11.102 sand mortar 1:6 in super structure.
a First Storey Cum 30.18 - 2,856.51 -
b Second Storey Cum 34.76 - 2,867.40 -
c Third Storey Cum 34.76 - 2,878.31 -
HSR Top khurra 0.6 m x 0.6 m for rain water pipe in 25 mm thick cement concrete 1:2:4 over 50
13.50. mm thick cement concrete 1:8:16.
HSR Cement Concrete 1:2:4 gola 10cm x 10cm quadrant along junction of roof with parapet
13.64 wall finished smooth, where specified.
HSR Providing & Fixing PVC Rainwater Pipe 6 kg. pressure of ISI mark in cement mortar during
13.89 masonry work. Make:- Supreme, Finolex, Prince.
a 100 mm dia PVC pipe 6 kg. pressure. Rmt 8.00 8.00 230.74 1,845.92
b 150 mm dia PVC pipe 6 kg. pressure. Rmt 620.00 620.00 426.80 2,64,619.02
23 Providing and fixing PVC Bend ISI Mark. Make:- Supreme, Finolex, Prince. - - -
Providing and fixing false Ceiling with 12mm thick Gypsum Board fixed on M.S. steel
24 runners frame i/c cost. Of screws angles, cleats, rawel plugs, with taping, filing with Gypsum Sqm 2,156.80 2,156.80 697.29 15,03,914.08
compound and applying priming coat. Etc. complete in all respects.
Authorised Signatory
Contractor BOQ Page No. 7 NBCC
Digitally signed by RAHUL
Construction of balance internal work of Library Building at Chaudhary Ranbir Singh University, Jind, Haryana at the Risk and Cost of M/s. R and B Infra Project Pvt. Ltd.
Total Balance Qty. to Rate at which
Quantity be executed at item was
Description of Item Unit in Original Risk & Cost Awarded in
Tender original tender
Providing and fixing mineral fibre false ceiling tiles at all heights of size
595X595mm of approved texture, design and pattern. The tiles should have Humidity
Resistance (RH) of 99%, Light Reflectance ?85%, Thermal Conductivity k = 0.052 - 0.057
w/m K, Fire Performance as per (BS 476 pt – 6 &7)in true horizontal level suspended on
interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick
(galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross
T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm
of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using
25 galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash Sqm 3,594.66 3,594.66 813.51 29,24,277.38
fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level
adjuster of size 85x25x2mm, spaced at 1200 mm centre to centre along main ‘T’. The system
should rest on periphery walls /partitions with the help of GI perimeter wall angle of
size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic
rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed
bottom portion of all T-sections used in false ceiling support system shall be pre-painted with
polyester baked paint, for all heights. The work shall be carried out as per specifications,
drawings and as per directions of the Engineer-In-Charge. With or without groves.
Providing and fixing tiled false ceiling of approved materials of size 595x595mm in
true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel
sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main “T” runner
with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm
thick (minimum) sheet, spaced at 1200 mm center to center and cross “T” of size 24x25 mm
made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600
mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600
HSR mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle
13.98 of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3
mm and laying false ceiling tiles of approved texture in the grid including, required
cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke
detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats of size
27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4
mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced
at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections
shall be pre-painted with polyester paint, all complete for all heights as per specifications,
GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size
595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of
100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and
having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of
thickness 60 microns (minimum), including factory painted after bending and perforation, and
backed with a black Glass fiber acoustical fleece.
Kotah stone Flooring minimum 25mm thick, in any pattern as specified over 20 mm thick
base of cement coarse sand mortar 1:3 laid and jointed with neat cement slurry mixed with
27 pigment to match the shade of stone including rubbing and polishing. - - -
Note:- 1st class spotless uniform color Kotah stone ( RATIYA Variety) including
single piece used in staircase shall be used.
Authorised Signatory
Contractor BOQ Page No. 8 NBCC
Digitally signed by RAHUL
Construction of balance internal work of Library Building at Chaudhary Ranbir Singh University, Jind, Haryana at the Risk and Cost of M/s. R and B Infra Project Pvt. Ltd.
Total Balance Qty. to Rate at which
Quantity be executed at item was
Description of Item Unit in Original Risk & Cost Awarded in
Tender original tender
Kotah stone 20 mm thick in skirting risers of steps, dados pillars and wall facing
(lining) in any pattern as specified 12 mm thick cement coarse sand plaster 1:3 laid and
HSR jointed with neat cement slurry, mixed with pigment to match the shade of stone including
14.66 rubbing & Polishing including labour for mixing cramps, dowels and pins etc.
Note:- 1st class spotless uniform color Kotah stone ( RATIYA Variety) including
single piece used in staircase shall be used.
c Second Storey Sqm 3.40 3.40 877.48 2,983.42
d Third Storey Sqm 3.40 3.40 878.59 2,987.19
e Fourth Storey Sqm 3.40 3.40 879.69 2,990.96
f Fifth Storey Sqm 3.40 3.40 880.80 2,994.73
g Sixth Storey Sqm 3.40 3.40 881.91 2,998.51
29 Stamping or making grooves on top of steps in stair case. Sqm 489.28 489.28 12.15 5,944.58
Providing and fixing Vitrified Tiles of size 600 x 600 mm of approved make in flooring laid
in any pattern as specified over base of 20mm thick cement coarse sand mortar 1:3 and
30 jointed with white cement slurry mixed with pigment to match the shade to tiles. - - -
Note:- 1. Tile shall be of premium quality (first quality) of reputed manufacturer like:
NITCO, KAJARIA, SOMANI, ORIENT BELL, JOHNSON, RAK AND SIMPOLO.
Providing and fixing Vitrified Tiles of size 600 x 600mm of approved make in
skirting/dados laid in any pattern as specified over base of 12mm thick cement coarse sand
HSR mortar 1:3 and jointed with White cement slurry mixed with pigment to match the shade to
Note:- 1. Tile shall be of premium quality (first quality) of reputed manufacturer like:
NITCO KAJARIA SOMANI ORIENT BELL JOHNSON RAK AND SIMPOLO
a First Storey Sqm 5.81 5.81 834.98 4,849.59
Authorised Signatory
Contractor BOQ Page No. 9 NBCC
Digitally signed by RAHUL
Construction of balance internal work of Library Building at Chaudhary Ranbir Singh University, Jind, Haryana at the Risk and Cost of M/s. R and B Infra Project Pvt. Ltd.
Total Balance Qty. to Rate at which
Quantity be executed at item was
Description of Item Unit in Original Risk & Cost Awarded in
Tender original tender
Providing & Fixing Ist quality Ceramic glazed wall tiles of Size of 200 x 300 mm
confirming to I.S. 15622 (thickness to be specified by the manu-facturer) of approved make
in all colours, shades except burgundy, bottle green, black of any size as approved by
HSR Engineer-In-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement
32 14.92 mortar 1:3 coarse and jointed with grey cement slurry, including ointing in white cement - - -
(a) mixed with pigment of matching shades complete.
1. Tile shall be of premium quality (first quality) of reputed manufacturer like: NITCO,
KAJARIA, SOMANI, ORIENT BELL, JOHNSON, RAK AND SIMPOLO.
Providing & Fixing Ist quality Ceramic glazed wall tiles of Size of 300 x 450 mm
confirming to I.S. 15622 (thickness to be specified by the manu-facturer) of approved make
in all colours, shades except burgundy, bottle green, black of any size as approved by
HSR Engineer-In-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement
33 14.92 mortar 1:3 coarse and jointed with grey cement slurry, including ointing in white cement - - -
(b) mixed with pigment of matching shades complete.
1. Tile shall be of premium quality (first quality) of reputed manufacturer like: NITCO,
KAJARIA, SOMANI, ORIENT BELL, JOHNSON, RAK AND SIMPOLO.
HSR Providing Double edge moulding to 17-20mm thick Granite counters, Vanities, treads of
34 14.98 stair case etc., including machine polishing to edge to give high gloss finish etc. complete as Rmt 1,805.61 1,805.61 264.13 4,76,906.74
(ii) per design approved by Engineer-in-Charge.(Moulding).
35 12mm thick cement plaster on walls (1:6). - - -
a Basment Sqm 95.64 - 78.76 -
h Seventh Storey Sqm 237.32 237.32 86.75 20,587.45
36 15mm Thick Cement Plaster 1:6 on the rough side of single or half brick wall. - - -
a Basment Sqm 95.64 - 96.88 -
b First Storey Sqm 993.42 - 96.88 -
Authorised Signatory
Contractor BOQ Page No. 10 NBCC
Digitally signed by RAHUL
Construction of balance internal work of Library Building at Chaudhary Ranbir Singh University, Jind, Haryana at the Risk and Cost of M/s. R and B Infra Project Pvt. Ltd.
Total Balance Qty. to Rate at which
Quantity be executed at item was
Description of Item Unit in Original Risk & Cost Awarded in
Tender original tender
37 10mm Thick Cement Plaster 1:4 on under side of ceiling. - - -
HSR Painting Two coats excluding priming coat with synthetic enamel paint in all shades
16.3 on new wood work or metallic or plastered or concrete surfaces to give an even shade.
HSR Applying priming coat with metal primer on new steel or iron work including preparation
16.9 of surface.
HSR Painting two coats with plastic emulsion paint on walls on new work to give an even
HSR Distempering with washable oil bound Distemper two coats excluding priming coat on new
16.79 Providing two coats of exterior acrylic emulsion paint.
(b) (b) Ist Quality.
Providing and applying two coats white cement based putty over plastered surface and
43 grindling the surface smooth with sand paper to get an even and smooth finish including cost Sqm 17,163.37 17,163.37 39.58 6,79,266.04
and carriage of all material, labour charges, scaffolding, sundries etc. complete. (J.K./ Birla).
HSR Providing and fixing teak wood beading to door and window chowkats with iron screws
44 17.54 fixed in position complete as per design and shape required. Rmt 109.48 109.48 67.40 7,379.47
45 Supplying and fixing hydraulic door closer I.S.I mark, with necessary screws etc. complete. - - -
(b) I.S.I designation no. II (size of door 701 mm to 850 mm) Each 8.00 8.00 863.79 6,910.36
.(c) I.S.I designation no. II (size of door 851 mm to 1000 mm) Each 62.00 62.00 914.93 56,725.60
HSR Factory manufactured Solid Flush Door Shutter, with block board core as per I.S. No.
17.93 + 1659-1969 bonded with water proof type phenol formaldehyde synthetic resin, hotpressed,
Note (i) conforming to I.S. 2202 part I and II, fixed in position, including iron hinges, screws,
46 (-) chocks/cleats and stops etc., (excluding the cost of any fittings other than specified above, - - -
HSR but including labour for fixing the same in position.
17.18 17.93: Note (i) Lipping of teak wood battens. 25 mm minimum depth on all edges of
Note(i) the shutter is provided.
Commercial veneering with vertical grains or cross bands and face veneer on both sides
(a)(ii) commercial facing with laminated core and lipped edges . Sqm 98.82 98.82 1,387.13 1,37,076.35
Authorised Signatory
Contractor BOQ Page No. 11 NBCC
Digitally signed by RAHUL
Construction of balance internal work of Library Building at Chaudhary Ranbir Singh University, Jind, Haryana at the Risk and Cost of M/s. R and B Infra Project Pvt. Ltd.
Total Balance Qty. to Rate at which
Quantity be executed at item was
Description of Item Unit in Original Risk & Cost Awarded in
Tender original tender
Commercial veneering with vertical grains or cross bands and face veneer on both sides
(a)(iv) commercial facing with laminated core and lipped edges . Sqm 178.20 178.20 1,545.61 2,75,427.11
Extra Labour for providing Rectangular Vision Panels in Commercial/Decorative flush
Providing and fixing Aluminum work for doors, windows, ventilators and partitions
with extruded built up standard tubular sections/appropriate Z. sections and other sections of
approved make conforming to IS;733 and IS;1285 fixed with raw plugs and screws or with
fixing clips or with expansion hold fasteners including necessary filling up of gaps at junctions,
at top, bottom, and sides with required neoprene felt etc. aluminum sections shall be smooth,
rust free straight mitered and jointed mechanically wherever required including cleat angle,
aluminum snap beading for glazing/paneling C.P brass/stainless steel screws, all complete.
Fixed portion (Anodized Aluminum transparent or dyed to required shade according to
IS;1868, minimum anodic coating of grade AC 15).
Note:-(ii) Polyster Powder coating of 50 micron is done instead of anodizing.
Providing and fixing aluminum work for doors, windows, ventilators and partitions
with excluded built up standard tubular sections/appropriate Z sections and other sections of
approved make conforming to IS;733 and IS;1285 fixed with rowel plugs and screws or with
fixing clips or with expansion hold fasteners including necessary filling up of gaps at junctions
HSR hold fasteners, at top, button, and sides with required neoprene felt etc. aluminum sections
17.96 + shall be smooth, rust free straight mitered and jointed mechanically wherever required
49 (Note ii including clear angle, aluminum snap beading for glazing/paneling C.P brass/stainless steel Kg. 2,476.80 2,476.80 332.54 8,23,644.83
of screws, etc complete, shutters of doors, windows & ventilators including providing
17.96) and fixing hinges/pivots and making provision for fixing of fittings wherever required
including the cost of PVC/neoprene gasket required including Aluminum fitting.
Openable Portion (Anodized Aluminum transparent or dyed to required shade according to
IS;1868, minimum anodic coating of grade AC 15).
Note:-(ii) Polyster Powder coating of 50 micron is done instead of anodizing.
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer
HSR or graded wood particle board conforming to IS:12823 grade I type II in panelling fixed in
50 17.97 aluminium doors, Windows shutters and partition frames with C.P brass/Stainless steel screws Sqm 42.34 42.34 865.61 36,646.53
(b) Pre-laminated particle board with decorative lamination on both sides
Providing and fixing glazing in aluminum door, windows, ventilator shutter and
partitions etc. with pvc/neoprene gasket etc. complete (cost of aluminum snap beading shall
be paid in the basis items ).
(b) With float glass panes of 5.00 mm thickness.
Providing and fixing Double glass glazing comprising of 6mm thick toughened clear glass
+ 12mm air gap + 5 mm annealed clear glass.
Wrought iron and mild steel (using angles, flats square bars, tees and channels) ladders,
HSR grills, gratting frames, window guards, iron doors openable or fixed stair case or parapet or
18.12 any other type of railing, gates and tree guards etc., including cost of screws and welding
rods or bolts and nuts complete fixed in position.
Authorised Signatory
Contractor BOQ Page No. 12 NBCC
Digitally signed by RAHUL
Construction of balance internal work of Library Building at Chaudhary Ranbir Singh University, Jind, Haryana at the Risk and Cost of M/s. R and B Infra Project Pvt. Ltd.
Total Balance Qty. to Rate at which
Quantity be executed at item was
Description of Item Unit in Original Risk & Cost Awarded in
Tender original tender
Supplying, hoisting and placing in position tubular trusses including runners, purlins,
consisting of steel tubes conforming to I.S. specifications of tested quality duly welded with
HSR fillet welds 6 mm thick through-out including wind bracing. Open end of pipe sealed with 3
18.14 mm thick plate including the cost of nuts and bolts where bolts connections are specified at
flange joints including one coat of ready mixed red oxide zink cromate primer of approved
quality assembling and fixed in position complete in all respect.
Steel reinforcement TMT bars FE-500 EQR / FE-500 D grade or more for RCC work,
where no included in the complete rate of RCC including straightening, bending, binding,
wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire
etc. and placing in position complete in all respects for all heights / depths / storeys /
55 Note: Reinforcement shall be measured in length including hooks, if any, separately for Qtls 9,893.24 - 5,876.57 -
different diameters as actually used in work, excluding overlaps. Wastage, overlaps,
couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other
methods for binding and placing shall not be measured and cost of these items shall be
deemed to be included in the rates for reinforcement.
Note:- Steel reinforcement TMT bars FE-550 D grade will be used
Pressed steel sheet frames (chowkats), consisting of 2 mm thick steel sheet of the
specified sections, including iron lugs (hold fasts), iron hinges, conforming to P.W.D.
HSR specifications, including bolts for fixing stops, locknotch, provision for receiving ower bolts,
18.34 and finished with one coat of ready-mixed paint red lead non-setting primer, of approved
quality, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame,
and cement concrete 1:3:6 for lugs complete.
(a) Door and window frame of size 89 mm X 50 mm with 40 mm wide single rebate. Rmt 254.25 254.25 453.56 1,15,316.47
(b) Door and window frame of size 76 mm X 38 mm with 35 mm wide single rebate. Rmt 268.80 268.80 371.47 99,849.90
(c) Door and window frame of size 127 mm X 50 mm with 40 mm wide single rebate. Rmt 139.35 139.35 486.84 67,840.49
HSR Providing and fixing rebaring work with chemical compound (make as approved by
18.42 Engineer-in-Charge) complete in all respect as approved by the Engineer-in- Charge.
(II) DSR ITEMS (WITH DISCOUNT FACTOR ON DSR-2018) - - -
DSR Providing and fixing in position 300 mm wide. Stainless steel Grade 304 plate-1.0 mm
5.43.2 thick as per design for expansion joints.
Authorised Signatory
Contractor BOQ Page No. 13 NBCC
Digitally signed by RAHUL
Construction of balance internal work of Library Building at Chaudhary Ranbir Singh University, Jind, Haryana at the Risk and Cost of M/s. R and B Infra Project Pvt. Ltd.
Total Balance Qty. to Rate at which
Quantity be executed at item was
Description of Item Unit in Original Risk & Cost Awarded in
Tender original tender
Providing and fixing of expansion joint system related with floor location as per
drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum
base members, self aligning / self centering arrangement and support plates etc. as per ASTM
B221-02. The system shall be such that it provides floor to floor /floor to wall expansion
control system for various vertical localtion in load application areas that accommodates multi
directional seismic movement without stress to it's components. System shall consist of metal
profiles with a universal aluminum base member designed to accommodate various project
DSR conditions and finish floor treatments. The cover plate shall be designed of width and
5.44.1 thickness required to satisfy projects movement and loading requirements and secured to
base members by utilizing manufacturer’s pre-engineered self- centering arrangement that
freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular
sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow
freedom of movement and flexure in all directions including vertical displacement. Provision of
Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory
requirement all as per the manufactures design and as approved by Engineer -in-Charge.
(Material shall confirm to ASTM 6063)
Providing and fixing of expansion joint system related with wall joint
(internal/external) location as per drawings and direction of Engineer-In- Charge. The
joints shall be of extruded aluminum base members, self aligning / centering arrangement
and support plates as per ASTM B221- 02. The material shall be such that it provides an
60 Expansion Joints System suitable for vertical wall to wall/ wall to corner application, Rmt 142.00 142.00 3,198.98 4,54,254.64
both new and existing construction in office Buildings & complexes with no slipping down
tendency amongst the components of the Joint System. The Joint System shall utilize light
weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap
locking the multicellular to facilitate movement. (Material shall confirm to ASTM 6063).
Providing and fixing of expansion joint system of approved make and manufactures
for various roof locations as per approved drawings and direction of Engineer-In-Charge.
The joints shall be of extruded aluminum base members with, self aligning and self centering
arragement support plates asper ASTM B221-02. The system shall be such that it
provides watertight roof to roof/roof to corner joint cover expansion control system that
is capable of accommodating multidirectional seismic movement without stress to its
components. System shall consist of metal profile that incorporates a universal aluminum
base member designed to accommodate various project conditions and roof treatments. The
61 cover plate shall be designed of width and thickness required to satisfy movement and loading Rmt 57.00 57.00 3,566.47 2,03,288.75
requirements and secured to base members by utilizing manufacturer’s pre-engineered self-
centering arrangement that freely rotates / moves in all directions. The Self centering
arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding
aluminum extrusion cavity to allow freedom of movement and flexure in all directions
including vertical displacement. The Joint System shall resists damage or deterioration from
the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic
from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to
have water tight joint is mandatory requirement.
Authorised Signatory
Contractor BOQ Page No. 14 NBCC
Digitally signed by RAHUL
Construction of balance internal work of Library Building at Chaudhary Ranbir Singh University, Jind, Haryana at the Risk and Cost of M/s. R and B Infra Project Pvt. Ltd.
Total Balance Qty. to Rate at which
Quantity be executed at item was
Description of Item Unit in Original Risk & Cost Awarded in
Tender original tender
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished,
machine cut for kitchen platforms, vanity counters, window sills, facias, and similar locations
of required size, approved shade, colour and texture laid over 20 mm thick base cement
mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with
62 matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to - - -
edges to give high gloss finish etc. complete at all levels.
8.2.2 : Polished Granite stone slab jet Black, Cherry Red, Elite Brown,Cat Eye or
8.2.2.1: Area of slab upto 0.50 sqm.
h Seventh Storey Sqm 0.54 0.54 2,673.38 1,448.97
Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with
67 stainless steel screws etc. complete : Each 787.00 787.00 75.99 59,807.31
Providing and fixing partition upto ceiling height consisting of G.I. frame and required
board, including providing and fixing of frame work made of special section power pressed/
roll form G.I. sheet with zinc coating of 120 gms/ sqm(both side inclusive), consisting of floor
and ceiling channel 50mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to
the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm
dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the
studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick
fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm
centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of
DSR partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at
9.105 spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25
mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre
to centre. The boards are to be fixed to the frame work with joints staggered to avoid through
cracks, Galvanised M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of
9.5 mm each with zinc coating of 120 gms/sqm(both side inclusive)) to be provided at the
horizontal joints of two boards, fixed to the studs using metal to metal flat head screws,
including jointing and finishing to a flush finish with recommended jointing compound, jointing
tape, angle beads at corners (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of
primer suitable for board as per manufacture's specification and direction of engineer in
charge all complete.
75 mm overall thickness partition with 12.5 mm thick double skin fire rated Glass
9.105.1 Reinforced Gypsum (GRG) plaster board conforming to IS: 2095: (part 3) : 1996 (Board with Sqm 69.72 69.72 1,379.64 96,188.58
BIS certification marks).
Providing & Fixing 1.00 mm thick decorative high pressure laminated sheet of plain /
DSR wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse
9.127.2 side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of
approved quality.
Authorised Signatory
Contractor BOQ Page No. 15 NBCC
Digitally signed by RAHUL
Construction of balance internal work of Library Building at Chaudhary Ranbir Singh University, Jind, Haryana at the Risk and Cost of M/s. R and B Infra Project Pvt. Ltd.
Total Balance Qty. to Rate at which
Quantity be executed at item was
Description of Item Unit in Original Risk & Cost Awarded in
Tender original tender
Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions
etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than
120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm
from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/
powder coating of not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20
mm size etc complete in all respect as per NBC 2016, IS 16231 (Part 3):2016 and as per
70 direction of Engineer-incharge with glass of required thickness having 120 minutes of fire Sqm 20.16 20.16 31,215.86 6,29,311.66
resistance both integrity & radiation control (EW120) and minimum 20 minutes of insulation
(EI20). The manufacturer have to give test report/certification of fire glass and the glass
should have the stamp showing the value of E, EW & EI. The glass shall be tested in approved
NABL accredited lab or by any other accreditation body which operates in accordance with
ISO/IEC 17011 and accredits labs as per ISO/IEC 17025 for testing and calibration scopes
shall be eligible. The maximum glazing size shall not be more than 1100x2200 mm (w x h) or
Providing and fixing bright /matt finished Stainless Steel handles of approved quality
71 & make with necessary screws etc all complete. Each 256.00 256.00 78.24 20,030.56
Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash
DSR fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter
10.27 sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in
frame , concrete/ masonry, etc. as per direction of Engineer-in-charge.
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes,
channels, plates etc., including welding, grinding, buffing, polishing and making curvature
(wherever required) and fitting the same with necessary stainless steel nuts and bolts
DSR complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners ,
10.28 stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with
suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight
of stainless steel members shall be considered excluding fixing accessories such as nuts,
bolts, fasteners etc.).
(11.41.3 Extra rate for using size 800 x 800 instead of 600 x 600 mm of vitrified tiles in both
- flooring and skirting.
Crazy ceramic tile flooring, with under layer 12 mm thick cement mortar 1:4 (1
cement: 4 coarse sand), with joints not exceeding 5 mm, including filling the gaps with
ordinary cement mixture & mixing with synthetic polyester fibre, triangular in shape having
75 specific gravity of 1.34 to 1.40, cross section size ranging from 10 to 40 micron & length upto Sqm 516.10 516.10 566.02 2,92,120.42
6 mm , mixing fibre @ 125 grams per 50 kg of cement in cement mortar, including providing
and mixing water proofing material in mortar @ 1 kg per 50 kg of cement, all complete as per
direction of Engineer-in-charge.
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix
of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin
76 per kg), including filling /grouting and finishing complete as per direction of Engineer-in- Sqm 3,685.36 3,685.36 141.89 5,22,907.94
11 48 3: Size of Tile 800x800 mm
Authorised Signatory
Contractor BOQ Page No. 16 NBCC
Digitally signed by RAHUL
Construction of balance internal work of Library Building at Chaudhary Ranbir Singh University, Jind, Haryana at the Risk and Cost of M/s. R and B Infra Project Pvt. Ltd.
Total Balance Qty. to Rate at which
Quantity be executed at item was
Description of Item Unit in Original Risk & Cost Awarded in
Tender original tender
Providing and laying Polished Granite stone flooring in required design and patterns, in
linear as well as curvilinear portions of the building all complete as per the architectural
drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4
77 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white - - -
cement slurry admixed with pigment of matching shade including rubbing , curing and
polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
Polished Granite stone slab jet Black, Cherry Red, Elite Brown,Cat Eye or equivalent.
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as
DSR per manufacturer’s specifications including appropriate priming coat, preparation of surface,
13.52.1 etc. complete
Providing and laying tactile tile (for vision impaired persons as per standards) of size
300x300x9.8mm having with water absorption less than 0.5% and conforming to IS:15622 of
DSR approved make in all colours and shades in for outdoor floors such as footpath, court yard,
16.90 multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4
coarse sand) in all shapes & patterns including grouting the joints with white cement mixed
with matching pigments etc. complete as per direction of Engineer-in-Charge.
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved
brand and manufacture, including providing and fixing top & bottom pivot & double action
81 hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing Sqm 86.40 86.40 3,524.41 3,04,509.03
required door fittings, all complete as per direction of Engineer-incharge (Door handle, lock
and stopper etc.to be paid separately).
Providing and laying water proofing treatment to vertical and horizontal surfaces of
depressed portions of W.C., kitchen and the like consisting of:
(i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound
conforming to IS 2645 in recommended proportions including rounding off junction of vertical
and horizontal surface.
82 (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water Sqm 2,660.93 2,660.93 447.15 11,89,840.98
proofing compound in recommended proportion including rounding off junction of vertical and
horizontal surface.
(iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area.
(iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be
100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm).
Authorised Signatory
Contractor BOQ Page No. 17 NBCC
Digitally signed by RAHUL
Construction of balance internal work of Library Building at Chaudhary Ranbir Singh University, Jind, Haryana at the Risk and Cost of M/s. R and B Infra Project Pvt. Ltd.
Total Balance Qty. to Rate at which
Quantity be executed at item was
Description of Item Unit in Original Risk & Cost Awarded in
Tender original tender
Providing and laying integral cement based water proofing treatment including
prepration of surface as required for treatment of roofs, balconies , terraces etc
With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
consisting of following operations:
a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water
proofing compound conforming to IS. 2645 and approved by Engineer -in-charge over the
RCC slab including adjoining walls upto 300 mm height including cleaning the surface before
b) Laying brick bats with mortor using brocken bricks /brick bats 25 mm to 115 mm size with
50 % of cement mortor 1:5 ( 1 cement : 5 coarse sand ) admixed with water proofing
compound conforming to IS :2645 and approved by Engineer -in-charge over 20mm thick
83 layer of cement mortor of mix 1:5 ) 1Cement : 5 coarse sand ) admixed with water proofing Sqm 1,436.83 1,436.83 886.51 12,73,762.76
compound conforming to IS : 2645 and approved by Engineer -in-charge to required slope
and treating similary the adjoining wall upto 300 mm height including rounding of junctions of
walls and slabs
c) After two days of proper curing applying a second coat of cement slurry using .2.75
kg/sqm of cement admixed jointless cement mortar of mix 1:4 admixed with water proofing
compound conforming to IS :2645 and approved by Engineer -in-charge
(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4
coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved
by Engineerin-chargeincluding laying glass fiber cloth of approved quility in top layer plaster
and finally finishing the surface with trowel with neat cement slurry and making pattern of
300 x 300 mm square 3mm deep.
TOTAL HSR - 2011 (WITH LATEST AMMENDMENTS) & DSR - 2018 (WITH DISCOUNTED FACTOR)
FOR : CIVIL WORK ABOVE PLINTH
(III) NON SCHEDULED ITEMS - - -
NS Providing Caress finishing to the granite including all tools and material required complete
C-2 in all respects to the entire satisfaction of the Engineer-In-Charge.
Providing & fixing Stainless Steel Fittings Heavy Duty (Brush Finished) to
89 doors,window,cupboard etc. (Grade 304) with nuts & screws etc complete.(as per sample - - -
approved by Engineer-in-charge):
i S.S tower bolt (200mm long) Each 177.00 177.00 188.06 33,286.09
ii S.S tower bolt (150mm long) Each 159.00 159.00 160.59 25,533.49
iii S.S sliding bolt (250 mm long)(16mm dia rod) Each 168.00 168.00 359.21 60,347.28
v S.S REAR MAGNETIC DOOR STOPER. Each 70.00 70.00 143.68 10,057.88
100 mm floor S.S front Door stoppers (Godrej or equivalent make) with rubber cushion
screws etc to suit shutter thickness complete.
Providing and fixing galvanized chicken wire mesh (24 gauge 12 mm size) to junctions
NS of concrete and masonry work and other locations including cutting to required sizes, side
C-5 laps of minium 75 mm and fixing in position with galvanized iron wire nails, complete in all
respects to the entire satisfaction of Engineer-In-Charge.
Extra rate for using Double charged Vitrified tiles instead of Single charged Vitrified
92 tiles in both flooring and skirting complete in all respects to the entire satisfaction of Engineer- Sqm 5,585.80 5,585.80 163.76 9,14,716.05
Authorised Signatory
Contractor BOQ Page No. 18 NBCC
Digitally signed by RAHUL
Construction of balance internal work of Library Building at Chaudhary Ranbir Singh University, Jind, Haryana at the Risk and Cost of M/s. R and B Infra Project Pvt. Ltd.
Total Balance Qty. to Rate at which
Quantity be executed at item was
Description of Item Unit in Original Risk & Cost Awarded in
Tender original tender
Providing and Fixing of Acoustic Wall panelling with grooved panel having system NRC
up to 0.75 with lineal perforation. The high grade MDF panels shall be melamine laminate of
size 2440X128mmX16mm with 2mm groove at 14mm pitch of 10mm perforation , Tongue
and Groove edges for seamless mounting having density of 700kg/m3(base panel confirming
to IS 12406 and laminated panel confirming to IS 14587). The back of the panels are
perforation of 10mm circular perforation of 1064nos in 0.312 sqmt backlined with a acoustics
fleece covering of 0.2mm for providing Sound absorption via the acoustic impedance method.
93 Panel is fixed by using GI Framework 2400mmx50mmx0.50mm spaced at 600mmx600 c/c & Sqm 2,236.50 2,236.50 6,520.72 1,45,83,585.81
16mm Aluminium framework spaced at 400mm centers with suitable brackets/metal clips at
corner and center of two slats. @400mm center to center, the system is backline with 50 mm
Rockwool insulation having 48kg/m3 density and along with all accessories example: chicken
mesh and all. as per architect design/drawing complete in all respects to the entire
satisfaction of Engineer-In-Charge.
Note:- 1.Serew/ Nails shall not be used for fixing of slats.
2. Shop drawings to be got approved prior to execute the work.
Providing & Fixing of Acoustical Suspended Ceiling System – Square edge tile Lay in on
24 mm exposed color Grid matching to tile, High grade perforated woodfiber/HDF panels
having melamine laminated perforation area of 25% to 30% should have Humidity
Resistance (RH) of 70% at 50 degree Celsius, upto NRC 0.90, Light Reflectance >color
dependent with Fire Resistance as per BS476 (Part 1) in module size of 595 X 595 X 12 mm
@ 700kg/m3 density, Green (VoC E1 Grade, RC 25%) backed with acoustical fleece in white
color of 0.2mm thick. The Grid should be 24 mm wide T sections i.e. the Main Runner
3600mm in web height of 38 mm & thickness 0.3mm, 1200 mm & 600 mm Cross Tees in web
height of 32mm & thickness 0.3mm to comprise main runner spaced at 1200mm centers
94 securely fixed to the structural soffit using suspension system at 1200mm maximum centre. Sqm 1,437.87 1,437.87 4,008.36 57,63,484.88
The First/Last suspension system at the end of each main runner should not be greater than
450mm from the adjacent wall. Flush fitting 1200mm long cross tees to be interlocked
between main runners at 600mm centre to form 1200 x 600 mm module. Cut cross tees
longer than 600mm require independent support. 600 x 600mm module to be formed by
fitting 600mm long flush fitting cross tees centrally between the 1200 mm cross tees.
Perimeter trim to be wall angles of size 3000x24x24x0.4mm, secured to walls at 450 mm
maximum centers as per architect design/drawing complete in all respects to the entire
satisfaction of Engineer-In-Charge.
Note:- Grid system shall be coated with minium of 120 GSM
Providing and fixing Signages with 5mm thick Solid Acrylic Cut Plate ( Size 9" x 4" )
95 and Raised Braile Language including all necessary accessories for fixing as per design given Each 240.00 240.00 1,647.08 3,95,300.04
by architect, complete in all respects to the entire satisfaction of Engineer-In-Charge.
Providing and fixing Precast terrazzo tiles 30 mm thick of size 400 x 400 mm in 50%
NS white and 50% grey cement. with graded marble chips of size upto 12 mm laid on 20 mm
C-11 thick bed of cement coarse sand mortar 1:3 with neat cement slurry, between joints and
over the base in floors treads of steps and landings including rubbing and polishing complete.
Providing & fixing of mirror finish stainless steel cladding to columns of 304
grade, 2.mm thick sheet including welding, buffing, grinding, polishing & curvature as desired
98 & fitting the same including main frame of verticals and horizontals made out of 45 x 45 x 1.6 Sqm 273.24 273.24 20,931.38 57,19,289.72
mm extruded aluminium sections as per drawing,cost of fastner, nuts bolts required for fixing
complete in all respects.
Authorised Signatory
Contractor BOQ Page No. 19 NBCC
Digitally signed by RAHUL
Construction of balance internal work of Library Building at Chaudhary Ranbir Singh University, Jind, Haryana at the Risk and Cost of M/s. R and B Infra Project Pvt. Ltd.
Total Balance Qty. to Rate at which
Quantity be executed at item was
Description of Item Unit in Original Risk & Cost Awarded in
Tender original tender
Providing and fixing Wooden Panelling on Walls comprising of 1.00 mm thick decorative
high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high
density protective surface layer over 12mm thick commercial ply fixed to G.I. section for wall
paneling using PlyWood fixed on the 'W' profile (0.55 mm thick) having a knurled web of
51.55 mm and two flanges of 26 mm each with lips of 10.55 mm, placed @ 610 mm C/C in
99 perimeter channel having one flange of 20 mm and another flange of 30 mm with thickness of Sqm 105.42 105.42 2,022.14 2,13,180.17
0.55 mm and web of length 27 mm. Perimeter channel is fixed on the floor and the Wall with
the nylon sleeves @ 610 mm C/C with fully threaded self-tapping dry wall screws. Plywood is
fixed to the 'W' profile with 25 mm countersunk ribbed head screws @ 200 mm C/C., as per
pattern given in the drawing or as per specifications and directions of Architect / Engineer-in-
Supplying and fixing of minimum 52mm thick Non-Metallic Fire Proof Doors of 120
minutes fire rating consisting of :
1. DOOR FRAME: Made of Red Merranti Frame of section 140mm x 70mm with heat
activated intumescent fire seal strip of size 10mm x 4mm (Marshall/Lorient /Astroflame) and
one coat of anti-termite fire retardent primer.
2. DOOR SHUTTER: Made of 52mm thick asbestos free composite fire /smoke check wodden
shutters of 120 minutes fire rating conforming to BS: 476 Part 22 & IS:3164 Part-2
NS comprising of two 9 mm thick starpan calcium silicate boards, a 100% without asbestos,
C-17 brucit and meerschaum, having density not less than 1150 kg/Cum and thermal conductive
0.14 W/m*K ply on both side and heat activated intumescent fire seal strip of size 10mm x
4mm mounted in the grooves of hardwood lipping on all sides expect bottom. The
manufacturer shall have already tested a proto type door duly attested from CBRI Rookee
with vision panel for both single and double leaf shutter prior to supply. The item also includes
1 mm thick laminate of approved shade and colour on both sides, SS Ball Bearing hinges of
Size 100 x 75 x 3mm with ss screws and anchor fastner of Size M10x120mm of approved
make. Size of clear opening of wall to be measure for payment purpose.
Supplying and fixing of 120 minutes fire rated CBRI tested as per IS:3614 Part-2 and
BIS:7 Part-22 stainless steel 304 grade outside access device (Trim and Lock)
104 compatible with single and double leaf panic bars from IR Monarch Series/Dorma PHA Each 28.00 28.00 6,865.14 1,92,223.84
Series/Marshall/BAKER FS/ASSA ABLOY MH-PB-SS series prior tested from CBRI Roorkee
along with fire door to be approved by the Engineer- in- charge, all complete.
Supplying and fixing of 120 minutes fire rated CBRI tested as per IS:3614 Part-2 and
BIS:7 Part-22 stainless steel 304 grade push type panic bars on double leaf door
105 shutters from IR Monarch Series/Dorma PHA Series/Marshall/BAKER FS/ASSA ABLOY/BAKER Each 28.00 28.00 22,653.47 6,34,297.24
FS MH-PB-SS series prior tested from CBRI Roorkee along with fire door to be approved by
the Engineer- in- charge, all complete.
Supplying and fixing of 120 minutes fire rated CBRI tested as per IS:3614 Part-2 and
BIS:7 Part-22 Door closer having rack & pinion mechanism, with standarad arm, dual
106 speed control, CE certifier, IR LCN 1461 Series/Dorma TS-73 Series/Marshall/ASSA ABLOY MH Each 28.00 28.00 7,001.43 1,96,039.91
DC-S-14003 series prior tested from CBRI Roorkee along with fire door to be approved by the
Engineer- in- charge, all complete.
Authorised Signatory
Contractor BOQ Page No. 20 NBCC
Digitally signed by RAHUL
Construction of balance internal work of Library Building at Chaudhary Ranbir Singh University, Jind, Haryana at the Risk and Cost of M/s. R and B Infra Project Pvt. Ltd.
Total Balance Qty. to Rate at which
Quantity be executed at item was
Description of Item Unit in Original Risk & Cost Awarded in
Tender original tender
Supplying & installation of Frameless Internal Glass Partition with glass panel
having 12mm thick clear toughened glass as per darwing held together with Patch
fittings(SSS Finish) with SS 304G cover plate as approved by architect/Engineer-inCharge
such as Wall to Glass Clamping Patch, Glass to Glass connecting patch to wall/ceiling, Glass to
Glass Quadrapole connector, Door over panel side panel connector, etc. The fittings shall
made up of: Base material casting - Aluminium alloy with SS 304G cover plate secured with
small 'L' key, Finish of the material is SSS Finish. The above work includes cost of Patch
fittings, cutting of all necessary holes in glass, C-out required for fixing of fittings, sealing of
NS Joints with Structural Sealent/Weather Sealent as required and all labour, T&P, scaffolding,
C-21 other incidental charges including wastage, enabling temporary services all fittings/fixtures,
nut bolts, washer, Buffer plates, fastener, anchors required for installation of Glass partition
complete in all respects to the entire satisfaction of Engineer-in-charge. Any other
fittings/fixtures required to make the partition operational to be provided by the contractor
and nothing extra shall be paid for this. (Any MS Structural members if required shall be paid
seperately under HSR Item.)
Note: The rate shall be same for all height/level. For the purpose of Payment, actual
opening area of glazing including thickness of joints but excluding area for opening
of doors shall be measured.
Providing and fixing of Hardware/Fittings of SS 304G - SSS Finish for Frameless
Glass Door as approved by architect/Engineer-in-Charge. The fittings shall made up of: Base
material casting - Aluminium alloy with SS 304G cover plate secured with small 'L' key, Finish
of the material is SSS Finish. Fittings/Hardware to be used are as under:-
(a)- Top Patch: Variable pivot point of 55 or 65mm With SS 304 cover Cover secured with
small ‘L’ key, Base material Casting:-Aluminium alloy, Finish: SSS (1-Nos).
(b)- Bottom Patch: Variable pivot point of 55 or 65mm Compatible with Floor Spring With SS
304 cover Cover secured with small ‘L’ key, Base Material Casting:-Aluminium Alloy, Finish:
NS (c)- D Type Pull Handle 32mm x 600mm with Back to Back installation on Glas Doors,
C-22 Gaskets to prevent the contact between glass and metal, Supporting washer, Grub screws
kept out of sight, Material:-Stainless Steel Grade 304, Finish: SSS (1-Set),
(d) Corner Patch Lock with Strike Plate with a euro profile cylinder and strike plate, Dead bolt
projection of 15mm (single throw) Three high security computer keys with SS 304 cover
secured with small ‘L’ key, Base Material Casting:-Aluminium Alloy, Finish: SSS ( 1 Nos).
The above work includes cost of Door fittings, cutting of all necessary holes in glass, C-out
required for fixing of fittings as required and all labour, T&P, scaffolding, other incidental
charges including wastage, enabling temporary services all fittings/fixtures, nut bolts, washer,
Buffer plates, fastener, anchors required for installation of Glass door complete in all respects
to the entire satisfaction of Engineer-in-charge.
TOTAL NON SCHEDULE ITEMS
FOR : CIVIL WORK BELOW PLINTH
(3). PUBLIC HEALTH WORK - - -
(I) HSR ITEMS - - -
Authorised Signatory
Contractor BOQ Page No. 21 NBCC
Digitally signed by RAHUL
Construction of balance internal work of Library Building at Chaudhary Ranbir Singh University, Jind, Haryana at the Risk and Cost of M/s. R and B Infra Project Pvt. Ltd.
Total Balance Qty. to Rate at which
Quantity be executed at item was
Description of Item Unit in Original Risk & Cost Awarded in
Tender original tender
Excavation for pipelines running under pressure In trenches and pits, in open areas, where
disposal,Of surplus earth is done alongwith the alignment Including trimming & dressing
sides, leveling of beds of trenches to Correct grade, cutting joint holes, cutting trees and
HSR bushes, etc.,Refilling consolidation and watering of refill in 15 cm layers and Restoration of
6.8 (a) unmetalled or unpaved surface to its original condition, including the cost of dewatering of
rain Water, diversion of traffic, night signals, fixing caution boards, watching, Fencing etc.,
and outside the town in ordinary soil:-(a) without timbering and shoring upto 1.5 Metress
Making holes by cutting cores of appropriate dia in RCC floors and roofs of thickness upto
HSR 6” (six inches) for passing drain pipe 6” (six inches) internal diameter and repairing the
8.39 (a) hole after insertion of drain pipe etc.
including finishing complete so as to make it leak proof.
Making holes by cutting cores of appropriate dia in RCC floors and roofs of thickness upto
HSR 6” (six inches) for passing drain pipe 4” (four inches) internal diameter and repairing
8.39 (b) the hole after insertion of drain pipe etc.
including finishing complete so as to make it leak proof.
4 Cement concrete 1:8:16 with stone aggregate 40mm nominal size in foundation and plinth. Cum 26.10 26.10 1,851.60 48,326.78
HSR Cement concrete 1 : 2 : 4 with stone aggregate 20 mm Nominal size in foundation and
HSR Drilling and Tapping cast iron / D.I pipe lines of all diameters and screwing in ferrule and
28.22 connections-Size of ferrule.
b 15 mm internal diameter of pipeline. Each 1.00 1.00 103.96 103.96
Cutting holes upto 23 cm square through brick work in cement walls for pipes and
7 making good including repointing replastering and finishing according to existing finish where - - -
(i) 11.43 cm thickness of walls Each 50.00 50.00 59.16 2,958.20
(ii) 22.86 cm thickness of walls Each 50.00 50.00 86.00 4,299.96
Providing & fixing in position best Indian make bevelled edge 5.5 mm thick mirror
mounted on absetos sheet ground fixed in postion by means of 4 Nos. chromium plated brass
screws and washers over rubbers washers and rawl plug embeded in the wall or chromium
plated brass clamps with C.P. brass screws (as required by the engineer-in-charge) complete
including cutting and making good the walls etc.
(a) Indian Make (i) 600 mm x 450 mm.
13 PROVIDING AND FIXING IN POSITION BEST INDIAN MAKE FLEXIBLE TUBE CONNECTION. - - -
Providing and fixing in position C.I. Gully trap cover weighing approximately 7.26 Kg.
HSR and frame for gully trap chamber clear opening size 300 mm x 300 mm and out side size 330
30.85 mm x 330 mm including painting the exposed surfaces with 3 coats of black bitumastic
superior paint of approved manufacture etc.
Providing and fixing in position M.S. or heavy flat iron clamps made out of M.S. flat not
15 less than 5 mm of the approved design for fixing C.I. soil waste vent or anti pipes to walls - - -
complete in all respects. (a) for 100 mm interal diameter pipes.
(a) for 100 mm interal diameter pipes. Each 150.00 150.00 59.43 8,914.22
(b) for 75 mm interal diameter pipes. Each 200.00 200.00 52.30 10,459.35
Authorised Signatory
Contractor BOQ Page No. 22 NBCC
Digitally signed by RAHUL
Construction of balance internal work of Library Building at Chaudhary Ranbir Singh University, Jind, Haryana at the Risk and Cost of M/s. R and B Infra Project Pvt. Ltd.
Total Balance Qty. to Rate at which
Quantity be executed at item was
Description of Item Unit in Original Risk & Cost Awarded in
Tender original tender
Providing & Fixing in position gully traps fixed in cement concrete 1:4:8 complete with
H.C.I. grating 150 mm x 150 mm cast iron cover weighing approximately 7.26 Kg. and frame
HSR clear opening 300 mm x 300 mm and outside size 330 mm x 330 mm and chamber including
16 30.114 cost of all brick work in cement mortar 1:5 cement concrete 1:2:4, in coping black bitumastic Each 10.00 10.00 988.88 9,888.84
(b) superior paint of approved manufacture on all C.I. work as per standard design, minimum
depth of water should be 150 mm with a minimum seal 50 mm. (b) 100 internal diameter
H.C.I. gull trap.
Providing and fixing HDPE WATER STORAGE TANKS of sintex, Diplast, O.K. Supereme
make with coves/lids marked with IS: 12701 on roof top of buildings including cost of hoisting
17 30.119 and placing in position, making connections with inlet and outlet pipes, providing overflow & - - -
scour provisions with suiyable plug on scour pipe including cost of nipples, washers, flanges
for connections in tanks complete in all respects to the satisfaction of Engineer-in-charge.
(II) DSR ITEMS (WITH DISCOUNT FACTOR ON DSR-2018) - - -
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I.
brackets and stainless steel plug 40 mm,
18 including painting of fittings and brackets, cutting and making good the walls wherever - - -
17 10 1 Kitchen sink with drain board
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal
stability for hot & cold water supply, including all CPVC plain & brass threaded fittings,
19 including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & - - -
fittings with one step CPVC solvent cement and testing of joints complete as per direction of
Engineer in Charge.
18.7.4 32 mm Outer diameter of pipeline Rmt 150.00 150.00 456.94 68,540.44
18.7.5 40 mm Outer diameter of pipeline Rmt 100.00 100.00 616.72 61,672.13
18.7.6 50 mm Outer diameter of pipeline Rmt 100.00 100.00 859.09 85,909.30
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal
stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c
DSR fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with
18.8 one step CPVC solvent cement and the cost of cutting chases and making good the same
including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc.
18.8.1 15 mm internal diameter of pipeline Rmt 206.00 206.00 389.52 80,241.32
18.8.2 20 mm internal diameter of pipeline Rmt 793.20 793.20 454.65 3,60,631.72
18.8.3 25 mm internal diameter of pipeline Rmt 180.00 180.00 534.34 96,180.38
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and
21 making good the walls etc. - - -
Internal work - Exposed on wall
18.10.6 50 mm internal diameter of pipeline Rmt 100.00 100.00 748.09 74,808.65
DSR Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed
18.17.1 25 mm internal diameter Each 36.00 36.00 472.72 17,017.93
18.17.2 32 mm internal diameter Each 25.00 25.00 552.69 13,817.17
Authorised Signatory
Contractor BOQ Page No. 23 NBCC
Digitally signed by RAHUL
Construction of balance internal work of Library Building at Chaudhary Ranbir Singh University, Jind, Haryana at the Risk and Cost of M/s. R and B Infra Project Pvt. Ltd.
Total Balance Qty. to Rate at which
Quantity be executed at item was
Description of Item Unit in Original Risk & Cost Awarded in
Tender original tender
18.17.3 40 mm internal diameter Each 15.00 15.00 645.06 9,675.85
18.17.4 50 mm internal diameter Each 4.00 4.00 826.48 3,305.92
TOTAL HSR - 2011 (WITH LATEST AMMENDMENTS) & DSR - 2018 (WITH DISCOUNTED FACTOR)
FOR : PUBLIC HEALTH WORKS
(III) NON SCHEDULED ITEMS - - -
Providing and fixing UPVC SWR Ring fit Pipes/Fittings including jointing with 'O'seal
ring, single socket waste drainage pipe lines Type-B having 6 Kgf/cm2 conforming to
IS:13592-92 (Supreme/Finolex /Prince/ Diplast make) including all required UPVC SWR
26 Fittings for UPVC pipes, Type-B having 6 Kgf/cm2 conforming to IS:14735-99 - - -
(Supreme/Finolex/ Prince/ Diplast make) for UPVC inside/outside the building , including
jointing with seal ring, cutting, fixing the pipe complete in all respect to the entire satisfaction
of Engineer-in-Charge.
Providing & Fixing UPVC Floor Traps with 90mm dia outlet. I.S.I. marked of the self
cleaning design including cement concrete 1:2:4 under and around the floor trap where
NS required upto floor level complete in all respects including cutting and making good the walls
PH-2 and floors, etc. minimum depth of water should be 50 mm with a minimum seal of 50 mm.
complete in all respects.
(Make Supreme/Finolex /Prince/ Diplast)
Providing & Fixing Stainless steel Jali With frame ( 100 mm dia) 304 G for Floor trap
28 including cutting and making good the walls and floors complete in all respects. Each 242.00 242.00 223.98 54,202.68
(Make VIKING/CHILLY/PRAYAG)
Providing & fixing in position 6mm thick Looking Mirror( Make Saint Gobain/Modi-
Guard/Asahi) including 6mm thick commercial ply on back side and teak wood moulding on
29 all sides as per approved design/drawing fixed in position by means of 4 Nos. S.S Studs with Sqm 21.60 21.60 2,727.88 58,922.27
S.S screws (as required by the engineer-in-charge) including cutting and making good the
walls etc. complete in all respects to the entire satisfaction of Engineer-in-Charge.
Providing and fixing in position European Type Rimless Wall Hung WC Bowl (CNS-WHT-
NS 963UFSM) of Size:375x510x355 mm,with UF soft close slim seat cover, Hinges, Fixing
PH-5 Accessories and Accessories set,complete in all respects of (JAQUAR or similar model of
Equivalent make such as Hindware/Kohler/Grohe etc.)
Providing and fixing in position Stainless Steel Jet Spray with 1 meter PVC tube (ALE-
31 547) including all fixtures, complete in all respects of ESSCO(Jaquar ) or similar model Each 97.00 97.00 444.79 43,144.29
of Equivalent make such as Hindware/Kohler/Grohe etc.)
Providing & fixing Exposed Part Kit of Concealed Stop Cock & Flush Cock ( FLR-5083NK) with
Fitting Sleeve, Operating Lever & Adjustable Wall Flange with Seal and Regular Body of
32 Concealed Stop Cock ( ALD-083) Suitable for 15 mm Pipe Line with Protection Cap (without Each 97.00 97.00 1,444.24 1,40,090.84
Exposed Parts) including all fixing accessories complete in all respects of (JAQUAR or
similar model of Equivalent make such as Hindware/Kohler/Grohe etc.)
Providing & fixing Toilet Roll Holder (ACN-1153S) with stainless steel flap including all fixing
33 accessories complete in all respects of (JAQUAR or similar model of Equivalent make Each 97.00 97.00 1,164.26 1,12,933.51
such as Hindware/Kohler/Grohe etc.)
Authorised Signatory
Contractor BOQ Page No. 24 NBCC
Digitally signed by RAHUL
Construction of balance internal work of Library Building at Chaudhary Ranbir Singh University, Jind, Haryana at the Risk and Cost of M/s. R and B Infra Project Pvt. Ltd.
Total Balance Qty. to Rate at which
Quantity be executed at item was
Description of Item Unit in Original Risk & Cost Awarded in
Tender original tender
Providing & fixing Oval shape Table Top Counter Wash Basin ( CNS-WHT-705) with Size: 500
NS x 380 x 120 mm including all fixing accessories with waste coupling (ALD-705L130) complete
PH-9 in all respects of (JAQUAR or similar model of Equivalent make such as
Hindware/Kohler/Grohe etc.)
Providing & fixing Wall Hung Wash Basin ( CNS-WHT-801) of Size: 550 x 400 x 195mm with
NS Full Pedestal (CNS-WHT-301) including all fixing accessories with waste coupling (ALD-
PH-10 705L130) complete in all respects of (JAQUAR or similar model of Equivalent make
such as Hindware/Kohler/Grohe etc.)
Providing & fixing Pressmatic Type Pillar Cock Auto Closing System with 65 mm extension
36 body (PRS-031L65) including all fixing accessories complete in all respects of (JAQUAR or Each 85.00 85.00 2,743.73 2,33,217.09
similar model of Equivalent make such as Hindware/Kohler/Grohe etc.)
Providing & fixing Soap Dispenser with Glass Bottle (ACN-1135N) including all fixing
37 accessories complete in all respects of (JAQUAR or similar model of Equivalent make Each 85.00 85.00 1,330.13 1,13,061.35
such as Hindware/Kohler/Grohe etc.)
Providing & fixing Hand Dryer satin finish (HDR-SAP-M99ACS) AISI 304 Stainless Steel
38 including all fixing accessories complete in all respects of (JAQUAR or similar model of Each 36.00 36.00 21,320.17 7,67,526.12
Equivalent make such as Hindware/Kohler/Grohe etc.)
Providing & fixing Urinal (URS-WHT-13261) Size:355x340x535mm including all fixing
39 accessories with waste coupling (ALD-705L130) complete in all respects of (JAQUAR or Each 48.00 48.00 4,901.10 2,35,252.97
similar model of Equivalent make such as Hindware/Kohler/Grohe etc.)
Providing & fixing Urinal Valve Auto Closing System (PRS-077) with Built-in Control Cock and
40 Flange including all fixing accessories complete in all respects of (JAQUAR or similar model Each 48.00 48.00 2,217.59 1,06,444.49
of Equivalent make such as Hindware/Kohler/Grohe etc.)
Providing & fixing Rectangular shaped urinal partition (JSE-CHR-810US450X) with 8mm
41 frosted glass including all fixing accessories complete in all respects of (JAQUAR or similar Each 48.00 48.00 5,278.27 2,53,357.15
model of Equivalent make such as Hindware/Kohler/Grohe etc.)
Providing & fixing Angular Stop Cock with wall Flange (FLR-5053N) including all fixing
42 accessories complete in all respects of (JAQUAR or similar model of Equivalent make Each 206.00 206.00 1,141.02 2,35,050.12
such as Hindware/Kohler/Grohe etc.)
Providing and fixing in position single piece slim Concealed Cistern (JCS-WHT-2400P)
NS with installation kit and P-type drain pipe connection set for Wall Hung WC with Flush
PH-18 Control Plate (JCP-CHR-102415) complete in all respects of (JAQUAR or similar model
of Equivalent make such as Hindware/Kohler/Grohe etc.)
Providing & fixing Fresh Color Restroom Cubicles Systems (MODEL TYPE - ZMS SS
SERIES) Thickness of Compact Laminate : 12 mm, Color of HPL Boards: Dual Colour, Size of
Cubicle : 1000mm (W) & 1550mm, (D) X 2003mm (H), Door Size : 1750mm (H) x 610mm
(W), Overall Height Of Cubicle : 2003mm, (Including bottom Gap of 150mm),Accessories:
NS Standard – Merino Make Aluminium, Stainless Steel - 304 Grade accessories) a) Aluminium
PH-19 “U” Channel, b) Aluminium “F” channel, c) Aluminium Door Stopper Channel, d) Aluminium
Top Rail, e) SS Coat Hook, f) SS Privacy Thumb turn c/w Occupancy Indicator, g) SS Door
Knob, h) SS Hinges with Cover, i) SS Adjustable Foot 316 Grade j) Rubber Door Stopper
Lining, k) S.S.Screws 304 G & P.V.C Wall Plugs complete in all respects to the entire
satisfaction of Engineer-in-Charge at per approve list of make.
TOTAL NON SCHEDULE ITEMS
FOR : PUBLIC HEALTH WORKS
(8). ELECTRICAL WORKS - - -
Authorised Signatory
Contractor BOQ Page No. 25 NBCC
Digitally signed by RAHUL
Construction of balance internal work of Library Building at Chaudhary Ranbir Singh University, Jind, Haryana at the Risk and Cost of M/s. R and B Infra Project Pvt. Ltd.
Total Balance Qty. to Rate at which
Quantity be executed at item was
Description of Item Unit in Original Risk & Cost Awarded in
Tender original tender
(I) HSR ITEMS - - -
Supply and erection of moulded case circuit breakers on wall or on existing pedestal
including bonding to earth and necessary connections :-
Supply and erection of sheet steel enclosure 2 pole / 3 pole with earth plug and socket
2 suitable for incorporating single pole / triple pole MCB on wall / on existing pedestal complete - - -
with necessary connections etc.
(ii) S.P.N. enclosure for single pole MCB 20 amp. Each 8.00 8.00 541.72 4,333.76
3 Supply and erection of Blanking Sheet in existing distribution board. Each 482.00 482.00 4.16 2,006.38
HSR Supply and erection of miniature circuit breaker / isolator 240 /415 V in the existing
31.17 distribution board including making necessary connections.
(a) Miniature circuit breakers of 9 KA breaking capacity. - - -
(ii) SP MCB of 9 KA breaking capacity 6 amp. to 32 amp. Each 3,600.00 3,600.00 140.51 5,05,852.20
(ii) SPN MCB of 9 KA breaking capacity 6 amp. To 32 amp. Each 76.00 76.00 291.38 22,145.09
(iii) TPN MCB of 9 KA breaking capacity 40 amp. to 63 amp. Each 108.00 108.00 738.07 79,711.66
5 Supply and erection of Fittings and Accessories. - - -
Supply and erection of hexagonal M.S. box 1.60 mm thick having each side 8 cms , 7.5
cms deep top covered with M.S. lid by means of screws including 10 mm dia 30 cm long mild
(xxvi) steel rod made into suitable suspension hook and erected in RCC slab for erection of fan , the Each 379.00 379.00 83.36 31,592.63
bottom covered with 3 mm thick bakelite sheet with suitable holes , painting etc. complete
with all labour and material required to complete the job.
HSR Supply and erection of pipe for wiring purposes including bends inspection boxes
31.21 etc. where necessary and painting as required.
(xv) Heavy gauge welded conduit pipe 20 mm dia 1.60 mm thickness on surface. Metre 3,500.00 62.11 70.84 4,399.77
(xvi) Heavy guage welded conduit pipe 25 mm dia 1.60 mm thickness on surface. Metre 4,500.00 3,459.00 87.48 3,02,587.09
Supply & erection of PVC pipe of 6KG pressure laid in 1 meter below ground level
complete inluding digging refilling of the trench with jointing etc.
(R) Lightning conductor - - -
8 (a) Copper. - - -
Excavation of earth pit 180 cm. round at top and 90 cm. at bottom 4.5 Metres deep and
refilling the same in plains including supply of necessary charcoal / coke and salt mixture.
Supply and erection of 60 cm. X 60 cm. X 3 mm thick copper plate including fixing with
nacessary bolts and nuts to coper tape .
Pdg. Standard watering tank including down pipe and C.I. cover with locking arrangement
Supply and erection of 20 mm x 3 mm thick lightning conductor copper tape fixed with
suitable copper stapples of same size.
Supply and erection of copper tape 32 mm x 6 mm thick from earth electrode directly in
ground and surface , fixed with suitable copper stapples of same size.
Authorised Signatory
Contractor BOQ Page No. 26 NBCC
Digitally signed by RAHUL
Construction of balance internal work of Library Building at Chaudhary Ranbir Singh University, Jind, Haryana at the Risk and Cost of M/s. R and B Infra Project Pvt. Ltd.
Total Balance Qty. to Rate at which
Quantity be executed at item was
Description of Item Unit in Original Risk & Cost Awarded in
Tender original tender
Supply and erection of 25 mm dia meter 1.5 Metre long lightning solid coper rod tappered
(a)(viii) into a point at the top with 16 cm. X 16 cm x 3 mm thick copper base plate and necessary Each 10.00 10.00 3,855.70 38,556.97
and bolts with washer.
Prioviding and fixing,testing joint made of 20mmx3mm thick copper strips 125mm long with 4
Nos. brass bolts and nuits, check nuts with washer complete.
(S) Under Ground Cables. - - -
HSR Supply of M.S.pipe (B-Class) for suspension rod of ceiling fan including threading if
31.35 (i) required.
Supply and erection of aluminium lugs heavy duty including crimping etc. upto the
entire satisfaction of the Engineer-in-charge of the work.
PVC Insulated wiring in recessed conduit. With Modular Accessories ( The cost of
Switch/Socket include in Point rates are recovered on Final Bills )
HSR Wiring in 1.5 sq.mm PVC Insulated copper conductor cable in 1.6 mm thick conduit
(i) Fan Point - - -
(ii) Long Point - - -
(iii) Twin control light point with 2 way 5 amp. single pole switch- - - -
(b) Medium point. Point 4.00 4.00 616.15 2,464.60
(vi) Call bell point including M.S Box of size 180mmx100mmx60mm deep for call bell- - - -
(vii) 3 pin 5 amp. plug point including earthing the 3rd. pin etc. - - -
3 pin 15 amp plug point including earthing the 3 rd. pin etc.with 4 sq mm PVC
insulated copper conductor cable.
Authorised Signatory
Contractor BOQ Page No. 27 NBCC
Digitally signed by RAHUL
Construction of balance internal work of Library Building at Chaudhary Ranbir Singh University, Jind, Haryana at the Risk and Cost of M/s. R and B Infra Project Pvt. Ltd.
Total Balance Qty. to Rate at which
Quantity be executed at item was
Description of Item Unit in Original Risk & Cost Awarded in
Tender original tender
HSR Supply and erection of PVC unsheathed copper conductor cable single core 1100 volts
31. 40 grade in pipe of suitable size excluding cost and erection of pipe.
(iii) Cable size 4.0 sqmm (7/0.85mm) ( for Power Points ) Metre 6,500.00 6,500.00 36.24 2,35,546.68
Supply and erection double door sheet steel enclosure distribution board suitable for
HSR MCB's and ELCB's etc. recessed in wall including bonding to earth with all labour and material
31. 41 required to complete the job in all respect upto to the entire satisfaction of Engineer-in-
Charge of work.
Supply and erection of PVC conduit pipe ISI marked (Medium) recessed in wall / ceiling
17 etc. including cost of PVC bends, inspection box and all other material requiredto complete the - - -
job in all respect to the entire satisfaction of Engineer-in-Charge of work.
HSR Pdg. and fixing modular type accessories of approved make in existing box including
31.56 fixing and making necessary connection, complete in all respect.
( vi ) Bell push ( for bell points) Each 30.00 30.00 118.54 3,556.18
( viii ) Call bell Ding-Dong ( Monitca ) Each 30.00 30.00 115.05 3,451.59
( ix ) Blanking Plate Each 249.00 249.00 29.05 7,234.38
Pdg. and fixing GI concealed sheet metal boxes inner and outer faceplate including
19 concealing the box in wall and fixing in position with inner plate and face plate with all labour - - -
and material requiered to complete the job in all respect.
Authorised Signatory
Contractor BOQ Page No. 28 NBCC
Digitally signed by RAHUL
Construction of balance internal work of Library Building at Chaudhary Ranbir Singh University, Jind, Haryana at the Risk and Cost of M/s. R and B Infra Project Pvt. Ltd.
Total Balance Qty. to Rate at which
Quantity be executed at item was
Description of Item Unit in Original Risk & Cost Awarded in
Tender original tender
Supply, Installation, Testing and Commissioning of wall / free standing floor
mounting dust & vermin proof compartmentalized cubical panel made out of 2 mm
thick CRCA sheet, required hardware 3 mm thick bakelite sheet provided all along the bus bar
and cable tray separating switches compartment and supporting suitable channel duly painted
by 2 coat zinc / red oxide primer followed by 2 coats of powder coating in grey or required
shade after rising. the panel having PU / Neoprene rubber gasket of not less than 3 mm
HSR thickness separate detachable gland plate MS base channel hinged door with inter locking
31.63 arrangement for equipments / switch wear. Transport acrylic sheet shall be provided in front
of bus bar compartment to prevent direct access to bus bar bakelite sheet 3 mm thick for
separately cable alley to BBC from switch chamber extended solid copper bars up to cable
alleys shall be provided for outgoing connection which shall be paid as extra items. Side walls
and cable alley compartments shall be having bolted type doors with detachable extension
type structure. The Panel will be complete with control wiring (Copper) and fuse protection.
(Only outer area on all sides shall be measured).
Supply and Fixing of copper bus bar duly tinned by means of SMC / DMC type insulator
HSR high tensile nuts and bolts spring washers fixing to same in existing panel including bending,
31.64 cutting in required shape and size and insulation with color coding heat shrinkable PVC
insulation complete in all respect.
Providing and Fixing of digital metering equipments for LT cubical panel consisting of
HSR 96 mm x 96 mm 0-500 Volt, Voltmeter with selector switch, Ampere meter of required ratio
31.65 up to 600/5 Amp. with selector switch and required CT's 3 Nos., a set of 3 Nos. phase
indication lamps RYB LED.
Supply and Fixing of rotary handle for ON / OFF operation of existing MCCB in the LT
23 panel including fixing the same in position with all labour and material to required to complete - - -
the job in all respect.
(i) Rotary Handle up to 125 Amp., MCCB Each 318.00 318.00 855.77 2,72,133.27
( ii ) Rotary Handle above 125 Amp., MCCB Each 7.00 7.00 1,001.56 7,010.93
Supply and erection of module case circuit breaker single pole/ 4 pole on wall /on existing
25 pedestal including bounding to earth and making necessary connection required to complete - - -
the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work.
Supply and laying of multicore telephone cable conductor size 0.51 mm bright
HSR annealed copper conductor PVC insulated and sealed in existing pipe/Channel and making
31.78 necessary connection complete in all respect upto the entire satisfaction of the Engineer-in-
Charge of the work.
i 2 pair telephone wire Metre 1,760.00 1,760.00 8.39 14,763.95
ii 5 pair telephone wire Metre 50.00 50.00 20.07 1,003.68
iii 10 pair telephone wire Metre 50.00 50.00 40.15 2,007.35
iv 20 pair telephone wire Metre 100.00 100.00 80.29 8,029.40
v 50 pair telephone wire Metre 95.00 95.00 180.66 17,162.84
HSR S/E/T/C of RG-11 COAXIAL cable(For TV/LCD) in existing PVC pipe /channel complete in
31.79 all respect with all labour and material required to complete the job in all respect.
Authorised Signatory
Contractor BOQ Page No. 29 NBCC
Digitally signed by RAHUL
Construction of balance internal work of Library Building at Chaudhary Ranbir Singh University, Jind, Haryana at the Risk and Cost of M/s. R and B Infra Project Pvt. Ltd.
Total Balance Qty. to Rate at which
Quantity be executed at item was
Description of Item Unit in Original Risk & Cost Awarded in
Tender original tender
TOTAL HSR - 2011 (WITH LATEST AMMENDMENTS) & DSR - 2018 (WITH DISCOUNTED FACTOR)
FOR : ELECTRICAL WORKS
(II) NON SCHEDULED Items. - - -
S/I/T/C of push ON/OFF type 25 A modular type motor starter switch (white color) for AC's
31 E-1 including the cost of petty material required to compete the job upto entire satisfaction of Each 76.00 76.00 541.98 41,190.82
Engineer-in-charge.
S/I/T/C of TV socket point (one module) including the cost of petty material required to
compete the job upto entire satisfaction of Engineer-in-charge.
S/I/T/C of Telephone socket point RJ11 (one module) including the cost of petty material
required to compete the job upto entire satisfaction of Engineer-in-charge.
41 E-11 S/I/T/C of RJ-45 internet jack complete in all respect. Each 72.00 72.00 460.63 33,165.65
EMERGENCY POWER SUPPLY:
Supply installation testing and commissioning of 3*80 KV A / 72KW, True online
double conversion. IGBT Rectifier & IGBT inverter having inbuilt phase corrector with 3
years free comprehensive warranty. Three phase Input / Three Phase Output with SMF
batteries Suitable for 15 Min backup on Full load (80 K V A) at 0.8 output power factor, 0.99
input THDI less than 5%. output voltage 3x380/400/415VAC + Neutral, static regulation ± 1
%, output wave from sinusoidal. Output THD is less than 3% for liner load, less than 5% for
nonlinear load. crest factor 3:1, over load 125% for 10 min, 150% for 1 min and should be
able to operate continuously at 115% load on bypass mode. battery voltage Adujustable from
384VDC to 480VOC on site, battery charger should be 24 amps or higher. Battery Bank sizing
at Minimum 48000VAH (Make of battery - Exide/SF/Rocket). overall efficiency at least 94% in
online mode, parallel communication port RS232. USB EPO and SNMP interface, BMS interface
are required. EMC-lEC62040-2 safety-lEC62040 I-I operating temperature 0-40 deg C relative
humidity 95% Non-Condensing. latest transformer free technology with static by pass and
manual by pass built in, third party test report through accredited lab like TUV is required for
lEC 62040-3 and IP20, test reports should not be oder than two years from date of tender.
UPS should have washable dust filters in front door, UPS should be provided with enviroment
monitoring probe to measure temperature and humidity of UPS room. SNMP software should
be compatible to Microsoft windows XP, Windows Vista 7, widows 8, Windows server 2003 R2.
2008. 2012 R2, UPS softwere should be compatible to latest virtualization softwere-VM were,
citrix etc. Monitoring softwere graphical interface should be compatible to google chorme,
mozila fire fox and Microsoft internet explorer. Battery rack, battery interlinks, battery
breaker, battery to UPS cable as required should be provided with UPS systems Including the
cost of petty material required to complete the job up to the entire satisfection of Engineer-in-
TOTAL NON SCHEDULE ITEMS
FOR : ELECTRICAL WORKS
(9). FANS AND FITTINGS WORKS - - -
(I) NON SCHEDULED Items. - - -
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated,
ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades,
30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor
not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM,
350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic
regulator unit for speed control and all remaining accessories including safety pin, nut bolts,
washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm,
suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
Authorised Signatory
Contractor BOQ Page No. 30 NBCC
Digitally signed by RAHUL
Construction of balance internal work of Library Building at Chaudhary Ranbir Singh University, Jind, Haryana at the Risk and Cost of M/s. R and B Infra Project Pvt. Ltd.
Total Balance Qty. to Rate at which
Quantity be executed at item was
Description of Item Unit in Original Risk & Cost Awarded in
Tender original tender
Supply, Installation, Testing and Commissioning of 400 mm sweep wall fan, 50W,
speed: 1350 rpm, Air Delivery: 72 cum/min , 3 nos. Sturdy & heavy duty aluminium blades
for higher air delivery , Pull card switch for speed & oscillation, suitable for 230 V, 50 Hz,
single phase AC Supply, earthing etc. complete as required.
Supply, Installation, Testing and Commissioning of 250 mm (non metalic) ventilator
fan, 35W, speed: 1200 rpm, Air Delivery: 860 cum/min, 3 nos. Sturdy & heavy duty
aluminium blades for higher air delivery , Pull card switch for speed & oscillation, suitable for
230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
Supply, Installation, Testing and Commissioning of 450 mm Turboforce Heavy Duty
(metal Body) Exhaust fans, 155W, speed: 1350 rpm, Air Delivery: 3900 cum/min,
Corrosion resistant body, minimal noise operation & maintenance free design, Totally
enclosed, highly efficient heavy duty motor with pressure die cast aluminium rotor mounted
4 F-4 on two ball bearings, Aerodynamically contoured blades handle maximum air with minimum Each 6.00 6.00 6,110.80 36,664.78
power consumption, Rigid frame with rubber mountings for silent operation,Conforming to IS:
2312 -1967, IP55 rated product (protected from limited dust ingress and from low pressure
water jets from any direction), suitable for 230 V, 50 Hz, single phase AC Supply, earthing
etc. complete as required.
SITC 36W LED 1200mm Batten Light. The EnduraLED Next (W/O PIR)is a surface & wall
5 F-5 mounting LED batten with extruded aluminium housing and robust construction . PF>.95, Each 317.00 317.00 1,025.86 3,25,198.10
System Wattage LED 36W with Minium 4100 lumens in 6500k.
S/E of recessed type 42 Watt full window glare free opal diffuse LED Panel of size
595x595 mm suitable for Armstrong/POP/GB ceiling with M.S. Powder coated white housing.
6 F-6 Total system lumen of 42 watt LED should be 5100 or above in cool day light (5600K to Each 798.00 798.00 5,461.05 43,57,916.70
6500K), Power factor >0.95, CRI (Ra) >80, LED Lamp efficiency ≥ 140 lm/w, Average life >
50000 hours, complete with all accessories as required with connections (Industrial).
S/I/T/C Surface Downlighter of Cree make LED15W 36 degree beam angle fixed
light distribution suitable for lamp 3000K IP40 and inbuilt heavy duty driver complete in all
respect with all accessories . Diffuser ensure the ingress protection and suitability for all
weather & all petty material required to complete connection the job in all respect.
SITC 50W Surface Downlight in ceiling of Size 800mm made of die cast aluminium with
fixed light distribution suitable for lamp 3000K and inbuilt heavy duty driver complete in all
respect with all accessories . Diffuser ensure the ingress protection and suitability for all
weather & all petty material required to complete connection the job in all respect.
SITC ceiling suspended 1200mm architectural line lumanries with high efficiency 36W
LED IP40 3000K diffused light produced with UV stablised non yellowing PMMA , Oceanic body
Is made of extruded aluminium & all petty material required to complete connection the job in
SITC of 36W Surface Downlight in ceiling of Size 600x600 made of die cast aluminium
with fixed light distribution suitable for lamp 3000K and inbuilt heavy duty driver complete in
all respect with all accessories & all petty material required to complete connection the job in
SITC of 3W COB downlight of Cree make LED 36 degree beam angle recessed in ceiling
11 F-11 with fixed light distribution suitable for LED Lamp IP40 with all accessories & all petty material Each 8.00 8.00 1,070.23 8,561.88
required to complete connection the job in all respect.
TOTAL NON SCHEDULE ITEMS
FOR : FANS AND FITTINGS
(10). FIRE FIGHTING WORKS - - -
(I) HSR/DSR ITEMS - - -
Authorised Signatory
Contractor BOQ Page No. 31 NBCC
Digitally signed by RAHUL
Construction of balance internal work of Library Building at Chaudhary Ranbir Singh University, Jind, Haryana at the Risk and Cost of M/s. R and B Infra Project Pvt. Ltd.
Total Balance Qty. to Rate at which
Quantity be executed at item was
Description of Item Unit in Original Risk & Cost Awarded in
Tender original tender
Part 2:- Fire Alarm System - - -
Supplying, installation, testing & commissioning of addressable beam detector with
1 short circuit isolator (inbuilt or seperate) complete with emitter and receiver including No 2.00 2.00 63,202.37 1,26,404.73
connections with remote test features etc complete as required.
Part 3:- Fire and Smoke Extraction System - - -
Supply, installation, balancing and commissioning of factory fabricated GSS sheet
DSR metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter
16.12.1 dampers, vanes,hangers, supports etc. as per approved drawings and specifications of
following sheet thickness complete as required.
Supply, installation, balancing and commissioning of fabricated at site GSS sheet
metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter
3 dampers, vanes, hangers, supports etc. as per approved drawings and specifications of - - -
following sheet thickness complete as required.
Supply, installation, testing and commissioning of GI volume control duct damper
4 complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per Sqm. 1.00 1.00 5,493.80 5,493.80
specifications.
Supply, Installation, Testing and Commissioning of wall / free standing floor
mounting dust & vermin proof compartmentalized cubical panel made out of 2 mm
thick CRCA sheet, required hardware 3 mm thick bakelite sheet provided all along the bus bar
and cable tray separating switches compartment and supporting suitable channel duly painted
by 2 coat zinc / red oxide primer followed by 2 coats of powder coating in grey or required
shade after rising. the panel having PU / Neoprene rubber gasket of not less than 3 mm
HSR thickness separate detachable gland plate MS base channel hinged door with inter locking
31.63 arrangement for equipments / switch wear. Transport acrylic sheet shall be provided in front
of bus bar compartment to prevent direct access to bus bar bakelite sheet 3 mm thick for
separately cable alley to BBC from switch chamber extended solid copper bars up to cable
alleys shall be provided for outgoing connection which shall be paid as extra items. Side walls
and cable alley compartments shall be having bolted type doors with detachable extension
type structure. The Panel will be complete with control wiring (Copper) and fuse protection.
(Only outer area on all sides shall be measured).(Total Area= 7.68+1.68+1.12=
Supply and Fixing of copper bus bar duly tinned by means of SMC / DMC type
HSR insulator high tensile nuts and bolts spring washers fixing to same in existing panel including
31.64 bending, cutting in required shape and size and insulation with color coding heat shrinkable
PVC insulation complete in all respect.
Providing and Fixing of digital metering equipments for LT cubical panel consisting of
HSR 96 mm x 96 mm 0-500 Volt, Voltmeter with selector switch, Ampere meter of required ratio
31.65 up to 600/5 Amp. with selector switch and required CT's 3 Nos., a set of 3 Nos. phase
indication lamps RYB LED.
Authorised Signatory
Contractor BOQ Page No. 32 NBCC
Digitally signed by RAHUL
Construction of balance internal work of Library Building at Chaudhary Ranbir Singh University, Jind, Haryana at the Risk and Cost of M/s. R and B Infra Project Pvt. Ltd.
Total Balance Qty. to Rate at which
Quantity be executed at item was
Description of Item Unit in Original Risk & Cost Awarded in
Tender original tender
Supply and Fixing of rotary handle for ON / OFF operation of existing MCCB in the LT
8 panel including fixing the same in position with all labour and material to required to complete - - -
the job in all respect.
(i) Rotary Handle up to 125 Amp., MCCB Each 7.00 7.00 855.77 5,990.36
( ii ) Rotary Handle above 125 Amp., MCCB Each 4.00 4.00 1,001.56 4,006.25
Supply and erection of module case circuit breaker single pole/ 4 pole on wall /on
HSR existing pedestal including bounding to earth and making necessary connection required to
31.69 complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the
vii 4 pole MCCB 300 amp to 400 amp Each 1.00 1.00 22,368.22 22,368.22
HSR Supply and erection of under ground cable ,loose in existing pipe or trenches complete
31.26 with necessary connections .
70 Sq. mm 3.5 Core Cable . ( for outgoing from 100A MCCB) 50x6=300mtr Rmt 300.00 300.00 317.90 95,370.26
95 Sq. mm 3.5 Core Cable . (for outgoing from 200A MCCB) 50x2=100mtr Rmt 100.00 100.00 383.83 38,382.65
185 Sq. mm 3.5 Core Cable . ( for inciming to 300A mccb) 100x1=100mtr Rmt 100.00 100.00 682.71 68,271.03
11 Earthing - - -
Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories
(iii) and providing masonry enclosures with cover plate having locking arrangement and Each 2.00 2.00 2,392.97 4,785.95
watering pipe etc. ( but without charcoal or coke and salt ) complete as required.
(v) Extra for charcoal or coke and salt for G.I. Plate or copper plate earth electrode. Each 2.00 2.00 982.55 1,965.09
Pdg. and fixing 25 mm x 5 mm G.I. Strip on surface or in recess for connections etc. as
required with all labour and material.
Pdg. and fixing 4.00 mm dia G.I.wire on surface or in recess for loop earthing as
Cabling & Conduiting:
DSR Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS
1.14 PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC
conduit as required.
Part 4:- Public Addressable and Evacuation System - - -
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable
DSR in the existing surface / recessed steel conduit of following pairs, cores and size including
17.5.3.2 connections and interconnections etc. as required.
17.5.3.2:- Speaker cable Two pair, 2-core, 1.5 sqmm
TOTAL HSR - 2011 (WITH LATEST AMMENDMENTS) & DSR - 2018 (WITH DISCOUNTED FACTOR)
FOR : ELECTRICAL WORKS
(II) NON SCHEDULED Items. - - -
Authorised Signatory
Contractor BOQ Page No. 33 NBCC
Digitally signed by RAHUL
Construction of balance internal work of Library Building at Chaudhary Ranbir Singh University, Jind, Haryana at the Risk and Cost of M/s. R and B Infra Project Pvt. Ltd.
Total Balance Qty. to Rate at which
Quantity be executed at item was
Description of Item Unit in Original Risk & Cost Awarded in
Tender original tender
Part 1:- Fire Hydrant System - - -
Supply, Installation. Testing and Commissioning of c-class M.S. pipes conforming to
IS:1239, including all fittings like anchor fasteners, brick masonry supports, couplings,
bends, elbows, tees & flanges, welded joints etc. as required, making good complete with
wrapping & coating , including the cost of digging of trench and back filling the same & cost of
the petty material required to complete the work with 3 Year free comprehensive warranty
period, upto the entire satisfaction of Engineer In Charge.(Under ground).
Supply. Installation. Testing and Commissioning of c-class M.S. pipes conforming to
IS:1239, Including all fittings like anchor fasteners, brick masonry supports, couplings,
15 FH-2 bends, elbows, tees & flanges welded or screwed joints etc. as required, making good -
complete with 3 Year free comprehensive warranty period including cost of petty material
required to complete the work upto the entire satisfaction of Engineer In Charge.(Above
Supply. Installation. Testing & Commissioning of P.N.1.6 Butterfly Valve, as per
IS:13095.complete with flanges, gasket, nut bolts for isolation with 3 Year free
comprehensive warranty period including cost of petty material required to complete the work
upto the entire satisfaction of Engineer In Charge.
Supply. Installation. Testing & Commissioning of 150mm dia Sluice Valve as per IS-
14846. complete with flanges, gasket, nut bolts with 3 Year free comprehensive warranty
period including cost of petty material required to complete the work upto the entire
satisfaction of Engineer In Charge.
Supply, installation, testing and commissioning of Fire Hydrant Valve (Landing Valve),
bearing to IS:5290 mark. S.S., 63mm. oblique instantaneous single outlet, 75mm. N.B.
18 FH-5 flangod inlet, spindle, complete with PVC blank cap., G.l. chain etc. with 3 Year free No. 18.00 18.00 7,116.58 1,28,098.51
comprehensive warranty period including cost of petty material required to complete the work
upto the entire satisfaction of Engineer In Charge.
Supply, installation, testing and commissioning of Branch Pipe, S.S.. short type, with
63mm. male instantaneous inlet, male threaded outlet, fitted with 16mm bore nozzle, as per
IS.318 LTB2/1S-903 with 3 Year free comprehensive warranty period including cost of petty
material required to complete the work upto the entire satisfaction of Engineer In Charge.
Supply, installation, testing and commissioning of Fire Hose, RRL hose jacketed with
circular woven synthetic fibre, conforming to IS: 638:88. 63mm.dia.x 15Mtr long with SS
heavy duty. 63mm. 2 pair of male and female instantaneous couplings, having IS: 903 mark
with duly S.S. wire wounded The hose shall be rolled and hug to suitable M. S. support in the
Fire Station, with 3 Year free comprehensive warranty period including cost of petty material
required to complete the work upto the entire satisfaction of Engineer In Charge.
Authorised Signatory
Contractor BOQ Page No. 34 NBCC
Digitally signed by RAHUL
Construction of balance internal work of Library Building at Chaudhary Ranbir Singh University, Jind, Haryana at the Risk and Cost of M/s. R and B Infra Project Pvt. Ltd.
Total Balance Qty. to Rate at which
Quantity be executed at item was
Description of Item Unit in Original Risk & Cost Awarded in
Tender original tender
Supply, Installation. Testing and Commissioning of weather proof standard FireHose
Cabinet box, with 5mm thick Single Glass Door, 18 SWG SS 304 sheet fabricated, including
21 FH-8 Lock & Key with PO Red Paint, rubber bidding, complete in all respect for external, Size No. 18.00 18.00 3,715.71 66,882.79
900x750x250. with 3 Year free comprehensive warranty period including cost of petty
material required to complete the work upto the entire satisfaction of Engineer In Charge.
Supply, Installation, Testing & Commissioning of 4 way Fire brigade inlet with 63 mm
dia instantaneous inlet as per IS:904 complete with all necessary fittings, with 3 Year free
comprehensive warranty period including cost of petty material required to complete the work
upto the entire satisfaction of Engineer In Charge.
Supply, Installation. Testing & Commissioning of 150 mm dia Dual Plate Non Return
Valve 150 mm dia, as per IS-14846,comp!ete with flanges, gasket, nut bolts with 3 Year
free comprehensive warranty period including cost of petty material required to complete the
work upto the entire satisfaction of Engineer In Charge.
Supply, installation, testing and commissioning of Manual Swing Type First aid
drum, Fire Hose Reel conforming to IS; 444 complete with heavy duty reel, 19mm dia.x
30Mtr. long, 2-ply polyester yarn braided /rubber braided pressure hose with heavy duty
nylon on/off jet/spray nozzle, 25mm isolating valve with 3 Year free comprehensive warranty
period including cost of petty material required to complete the work upto the entire
satisfaction of Engineer In Charge.
Supply. Installation. Testing & Commissioning of Pressure Gauge with gauge cock
25 FH-12 with 3 Year free comprehensive warranty period including cost of petty material required to No. 4.00 4.00 1,306.89 5,227.56
complete the work upto the entire satisfaction of Engineer In Charge.
Supply. Installation, Testing and Commissioning of Air cushion Tank (200mm dia x
1000mm height) fabricated from MS Sheet with dish ends, including fittings/accessories, with
26 FH-13 2 coats of Primer and P.O.Red Enamel Paint (Locally Fabricated) with 3 Year free No. 2.00 2.00 12,030.37 24,060.73
comprehensive warranty period including cost of petty material required to complete the work
upto the entire satisfaction of Engineer In Charge.
Supply, Installation, Testing and Commissioning of 25 mm dia Air Release Valve with
27 FH-14 3 Year free comprehensive warranty period including cost of petty material required to No. 2.00 2.00 1,520.30 3,040.61
complete the work upto the entire satisfaction of Engineer In Charge.
Supply. Installation. Testing and Commissioning of Electric driven Terrace pump
capacity 900 lpm.10 HP @ 30 MWC Head complete with base plate, coupling guard,
foundation bolts with 3 Year free comprehensive warranty period including cost of petty
material required to complete the work upto the entire satisfaction of Engineer In Charge.
Supply. Installation, Testing and Commissioning of 25 mm dia Gate Valve 25 mm dia
29 FH-16 with 3 Year free comprehensive warranty period including cost of petty material required to No. 30.00 30.00 991.00 29,729.91
complete the work upto the entire satisfaction of Engineer In Charge.
Supply and Fixing of Carbon Standard Fire Man Axe with 3 Year free comprehensive
30 FH-17 warranty period including cost of petty material required to complete the work upto the entire No. 14.00 14.00 1,520.30 21,284.25
satisfaction of Engineer In Charge.
Supply and fixing of 6kg ABC type fire extinguisher as per IS:15683(6 kg.) with 3 Year
31 FH-18 free comprehensive warranty period including cost of petty material required to complete the No. 30.00 30.00 2,357.05 70,711.55
work upto the entire satisfaction of Engineer In Charge.
Supply and fixing of 4.5kg C02 gas type fire extinguisher as per IS: 15683(4.5 kg.)
32 FH-19 with 3 Year free comprehensive warranty period including cost of petty material required to No. 30.00 30.00 5,508.59 1,65,257.73
complete the work upto the entire satisfaction of Engineer In Charge.
Authorised Signatory
Contractor BOQ Page No. 35 NBCC
Digitally signed by RAHUL
Construction of balance internal work of Library Building at Chaudhary Ranbir Singh University, Jind, Haryana at the Risk and Cost of M/s. R and B Infra Project Pvt. Ltd.
Total Balance Qty. to Rate at which
Quantity be executed at item was
Description of Item Unit in Original Risk & Cost Awarded in
Tender original tender
Providing and Fixing of MS angle iron frame duly painted, of standard height suitable to
hold 3 buckets at a time and Gl Filled sand Buckets painted RED complete with 3 Year free
comprehensive warranty period including cost of petty material required to complete the work
upto the entire satisfaction of Engineer In Charge.
Providing Elelctric Shock Treatment Chart of standard size duly framed and covered with
34 FH-21 5 mm thick glass etc. complete In all respects including the cost of all petty material required No. 7.00 7.00 1,717.87 12,025.08
to complete the job upto entire specifications of Engineer-in – charge.
Providing and laying antishock rubberised mat of 12mm thickness for Pump House
chamber complete in all respect with 3 Year free comprehensive warranty period including
cost of petty material required to complete the work upto the entire satisfaction of Engineer
* Pump House System - - -
Supply, Installation. Testing & Commissioning of Horizontally Centrifugal Single
Stage Electric driven fire pumping set having capacity 2280 Lpm @ 70 MWC Head
complete with base plate, coupling guard, foundation bolts., with TEFC Motor suitable for
415V ±10%, 3 Phase 50 Hz AC supply of suitable HP for above Pump running at 2900 RPM
with 3 Year free comprehensive warranty period including cost of petty material required to
complete the work upto the entire satisfaction of Engineer In Charge.
Supply, Installation, Testing & Commissioning of Jockey pump having capacity 180
lpm @ 70 MWC Head with 15 HP TEFC Motor complete with base plate, coupling guard,
foundation bolts. with 3 Year free comprehensive warranty period including cost of petty
material required to complete the work upto the entire satisfaction of Engineer In Charge.
Supply. Installation. Testing and Commissioning of 90 BHP Diesel Engine Driven Fire
Pump suitable for auto-matic/manual opeprations consisting of Single Stage Horizontal
Centrifugal Pumping Set capable for delivery of 2280 LPM against a total head of 70 Mtr.
38 FF-25 Head 1500/1800 RPM complete having proper connenction to suction and delivery line, Set 1.00 1.00 6,53,715.71 6,53,715.71
inclcuing 1 No. 200 Ltr. capacity of Fuel Storage Tank, fabricated from MS Plate 3/4 mm
thick, with 24/12 Volt Battery with 3 Year free comprehensive warranty period including cost
of petty material required to complete the work upto the entire satisfaction of Engineer In
Design, fabrication, assembling, wiring, supply, installation, testing and
commissioning of motor control centre fabricated out of 14 gauge CRCA sheet steel in
form in 3b formation with reinforcement of suitable size angle iron, channel ‘T’ sections irons
and/or flats wherever necessary. Cable gland plates shall be provided on top as well as at the
bottom of the panels. Panels shall be treated with all anticorrosive process before painting as
per specifications with 2 coats of red oxide primer and final approved shade of powder coated
paint. 2 Nos. earthing terminals shall be provided for 3 phase, 4 wire, 50 Hz supply system
with the 3 years free comprehensive warranty period. Lifting hooks shall also be provided .
Approval of design of panel shall be taken for each panel before fabrication.
39 FH-26 MCC-1 for fire fighting equipments: Incoming: Set 1.00 1.00 3,08,494.83 3,08,494.83
a. 1 Nos. 4 pole 500A 35KA breaking Capacity mechanical interlocked incoming MCCB
complete with the following:
i. 0-500 volts, 96 x 96mm square voltmeter with selector switch shall be protected by 2
amps TP MCB:1 Set.
ii. 0-500 amps, 96 x 96 mm square ammeter with 630/5 amps 15 VA CL:1 CT's and selector
iii. Phase indicating LED lamps shall be protected by 2 amps SP MCB: 3 Sets.
b. Aluminium bus bar sleeves type, rated at 800 amps for three phase & neutral phase bus
bar shall have maximum current density of 1 amps per sq.cm.
Authorised Signatory
Contractor BOQ Page No. 36 NBCC
Digitally signed by RAHUL
Construction of balance internal work of Library Building at Chaudhary Ranbir Singh University, Jind, Haryana at the Risk and Cost of M/s. R and B Infra Project Pvt. Ltd.
Total Balance Qty. to Rate at which
Quantity be executed at item was
Description of Item Unit in Original Risk & Cost Awarded in
Tender original tender
a. 2 Nos. 4 pole 250 amps 35 KA breaking capacity TPN MCCB outgoing feeders with 55 KW
DOL starters out going feeders for Hydrant / Sprinkler pump motor. The compartment shall
contain CT operated ammeter of 0-250 amps range with selector switch auto / manual
selector switch and indicating LED lamp with MCBs for `ON'/OFF/`TRIP' status of motor.
b. 3 Nos. 4 pole 63 amps 25 KA breaking Capacity TPN MCCB, 12.5 KW Direct online starter
with single phase preventer & phase reversal preventer and outgoing feeder to jockey pump
and terrace pump motor. The compartment shall contain CT operated ammeter of 0-63 amps
and indicating lamps with MCBs for `ON'/OFF/`TRIP' status of pump motors.
c. 2 No. suitable rating MPCB for 1.5 KW DOL starter and outgoing feeder to sump pumps in
plant room (including 1 Nos. standby). Each compartment shall contain auto / manual selector
swtich and indicating / pushbutton lamps with MCB for ON / OFF / TRIP of motor.
d. Providing and fixing 1 No. auto start panel activated with pressure switch for diesel engine
complete with all accessories, battery charger of suitable rating, MCB timers, push buttons,
microprocessor based alarm annunciator, wiring and cabling including connection to diesel
engine complete as required ready for working.
e. Necessary cable alleys space for spare switches, internal wiring and copper earthing of all
equipment shall also be included. All switch gears / control gears shall be compatible to motor
All MCCB's to be suitable for motor duty rating.
Provision shall be made for providing potential free contacts to all pumps starters for
connection to building automation system.
Supply, Installation. Testing and Commissioning of Pressure Switch, inclduing wiring
and connenction with Motor Control Panel for Automation of Panel with 3 Year free
comprehensive warranty period including cost of petty material required to complete the work
upto the entire satisfaction of Engineer In Charge.
Supply, Installation, Testing & Commissioning of Pressure Gauge 100/80 mm dia with
calibration of 0-14 Kg /Sq.Cm. with 3 Year free comprehensive warranty period including cost
of petty material required to complete the work upto the entire satisfaction of Engineer In
Providing & fixing MS Class ‘C’ diesel engine exhaust pipe (including all fittings, clamps,
steel support etc.) of 100mm dia for the engine. The pipe shall be insulated with 100 mm
thick mineral wool insulation wrapped in chicken mesh and clad with 24 gauge aluminium
sheet and with the 3 years free comprehensive warranty period.
Supply. Installation. Testing & Commissioning of c-class MS Pipe confirming to IS
1239 with primer,painting, fitting and necessary support with 3 Year free comprehensive
warranty period including cost of petty material required to complete the work upto the entire
satisfaction of Engineer In Charge.( Above ground)
Authorised Signatory
Contractor BOQ Page No. 37 NBCC
Digitally signed by RAHUL
Construction of balance internal work of Library Building at Chaudhary Ranbir Singh University, Jind, Haryana at the Risk and Cost of M/s. R and B Infra Project Pvt. Ltd.
Total Balance Qty. to Rate at which
Quantity be executed at item was
Description of Item Unit in Original Risk & Cost Awarded in
Tender original tender
Supply. Installation. Testing & Commissioning of PN 1.6 Butterfly Valve as per IS:
13095. complete with flanges, gasket, nut bolts etc. with 3 Year free comprehensive
44 FF-31 warranty period including cost of petty material required to complete the work upto the entire No. 6.00 6.00 8,623.15 51,738.92
satisfaction of Engineer In Charge.
b) 150 mm dia (Lever operated)
Supply. Installation. Testing & Commissioning of 150 mm dia Y type strainer
complete with flanges, gasket, nut bolts etc. with 3 Year free comprehensive warranty period
including cost of petty material required to complete the work upto the entire satisfaction of
Engineer In Charge.
Supply. Installation. Testing & Commissioning of Dual Plate Non Return Valve as per
IS:5312, complete with flanges, gasket and nut bolts. with 3 Year free comprehensive
warranty period including cost of petty material required to complete the work upto the entire
satisfaction of Engineer In Charge.
Supply. Installation. Testing & Commissioning of Anti Vibration expansion bellow
complete with flanges, gasket and nut bolts. with 3 Year free comprehensive warranty period
including cost of petty material required to complete the work upto the entire satisfaction of
Engineer In Charge.
Supply. Laying, Testing & Commissioning of Cabling for pump complete with base
saddle, lugs, ferrule laid in ground/wall as required with 3 Year free comprehensive warranty
period including cost of petty material required to complete the work upto the entire
satisfaction of Engineer In Charge.
a) 2 x 1.5 Sqmm Copper Armoured Cable RMT 200.00 200.00 80.29 16,058.80
Providing and fixing type air vessel of 300mm dia 1.5m height fabricated for out of
10mm thick MS plate suitable for 7 kg/cm2 working pressure complete with 25mm air release
valve, safety valve, pressure gauge etc. as required. The air vesel shall be continous welded
construction and painted with two coats of postal red enamel outside over a coat of primer
and epoxy paint inside. complete in all respect upto entire satisfaction of the Engineer-in-
Charge and with the 3 years free comprehensive warranty period.
Supply, Installation. Testing and Commissioning of 25 mm dia Air Release Valve 25
mm dia with required fittings with 3 Year free comprehensive warranty period including cost
of petty material required to complete the work upto the entire satisfaction of Engineer In
Supply. Installation. Testing & Commissioning of Draw Out Connection 150 mm dia.
51 FH-38 with 3 Year free comprehensive warranty period including cost of petty material required to No. 1.00 1.00 9,618.38 9,618.38
complete the work upto the entire satisfaction of Engineer In Charge.
Supply. Installation. Testing & Commissioning of 100 mm dia Foot Valve 100 mm dia.
52 FH-39 with 3 Year free comprehensive warranty period including cost of petty material required to No. 1.00 1.00 4,031.60 4,031.60
complete the work upto the entire satisfaction of Engineer In Charge.
* Sprinkler System - -
Authorised Signatory
Contractor BOQ Page No. 38 NBCC
Digitally signed by RAHUL
Construction of balance internal work of Library Building at Chaudhary Ranbir Singh University, Jind, Haryana at the Risk and Cost of M/s. R and B Infra Project Pvt. Ltd.
Total Balance Qty. to Rate at which
Quantity be executed at item was
Description of Item Unit in Original Risk & Cost Awarded in
Tender original tender
Supply. Installation. Testing and Commissioning of c-class M.S. pipes conforming to
IS:1239, Including all fittings like anchor fasteners, brick masonry supports, couplings,
bends, elbows, tees & flanges welded or screwed joints etc. as required, making good
complete with 3 Year free comprehensive warranty period including cost of petty material
required to complete the work upto the entire satisfaction of Engineer In Charge.(Above
Supply. Installation. Testing and Commissioning of of Pendant type Sprinkler 68 deg.
54 FH-41 with 3 Year free comprehensive warranty period including cost of petty material required to Nos. 1,225.00 1,225.00 391.96 4,80,152.84
complete the work upto the entire satisfaction of Engineer In Charge.
Supply. Installation, Testing and Commissioning of of Upwright type Sprinkler. with
55 FH-42 3 Year free comprehensive warranty period including cost of petty material required to Nos. 1,225.00 1,225.00 391.96 4,80,152.84
complete the work upto the entire satisfaction of Engineer In Charge.
Providing, fixing, testing & commissioning of U.L.listed corrugated SS-304 Braided
flexible sprinkler pipe droplet for 12 kg/ sq. cm. working pressure with 1/2" BSP threaded
56 FF-43 outlet & 1" BSP threaded inlet with reducer nipple, snap, clamp, T-bar bracket etc. with Nos. 1,225.00 1,225.00 596.92 7,31,230.06
necessary fitting complete as required. 1500 mm Length with the 3 years free comprehensive
warranty period.
Supply. Installation, testing and Commissioning of Normal type Rosette Plate for
57 FF-44 sprinkler with 3 Year free comprehensive warranty period including cost of petty material Nos. 1,225.00 1,225.00 80.29 98,360.15
required to complete the work upto the entire satisfaction of Engineer In Charge.
Supply, installation. Testing and commissioning of 150 mm dia Butterfly Valve with
flange, gaskets nut bolts Complelte in all respects with 3 Year free comprehensive warranty
period including cost of petty material required to complete the work upto the entire
satisfaction of Engineer In Charge.
Supply. Installation. Testing and commissioning of 150 mm dia Flow Switch complete
59 FF-46 in all respect. with 3 Year free comprehensive warranty period including cost of petty material Nos. 7.00 7.00 4,597.89 32,185.22
required to complete the work upto the entire satisfaction of Engineer In Charge.
Supply. Installation. Testing & Commissioning of 150 mm dia Installation Control
Valve Assembly complete in all respects with 3 Year free comprehensive warranty period
including cost of petty material required to complete the work upto the entire satisfaction of
Engineer In Charge.
Supply and Installation of 50 mm dia Ball Valve 50 mm dia with 3 Year free
61 FF-48 comprehensive warranty period including cost of petty material required to complete the work No. 17.50 17.50 4,105.56 71,847.28
upto the entire satisfaction of Engineer In Charge.
Supply and Installation of Gong Bell including cost of petty material required to complete
the work upto the entire satisfaction of Engineer In Charge.
Part 2- Fire Alarm System - - -
Authorised Signatory
Contractor BOQ Page No. 39 NBCC
Digitally signed by RAHUL
Construction of balance internal work of Library Building at Chaudhary Ranbir Singh University, Jind, Haryana at the Risk and Cost of M/s. R and B Infra Project Pvt. Ltd.
Total Balance Qty. to Rate at which
Quantity be executed at item was
Description of Item Unit in Original Risk & Cost Awarded in
Tender original tender
SITC of 4 Loop with Expendable Loops Micro processor based 1 wire fault tolerant
loop, required loop networkable type (each loop accessing 199 detectors and 199 modules )
fire alarm/detection control panel having 640 Character Display The panel shall be able to
give location of all fire/fault conditions of addressable units via the address codes. Further,
the panel must be able to automatically switch ON /OFF respective control module when ever
any alarm is triggered. The panel shall have rectifier, Loop cards, 80 character LCD unit to
indicate Fire/Fault Signal with addresses. The Panel Shall be Sheet Steel Painted, sealed to
IP30. The panel should have provision to integrate with PA System . The panel shall have a
built in power supply and battery charger along with maintenance free 24 AH, 2 x 12 volt
SMF Lead acid batteries capable of running for a minimum of 24 hours with battery charger
complete as required. and conforming to BS5839 Standards and Duly Approved by
64 FA-2 SITC of Active Repeator panel. Nos. 1.00 1.00 91,765.05 91,765.05
SITC of Analogue Addressable type Smoke Detector with Visible bi-color LEDs for 360
65 FA-3 deg having Rotary, decimal addressing system in the range of 01-159, complete with Nos. 790.00 790.00 2,405.44 19,00,296.97
standard base, as required, complying to EN54 and LPCB/UL.
SITC of Analogue Addressable type Heat Detector with Visible bi-color LEDs for 360 deg
66 FA-4 having Rotary, decimal addressing system in the range of 01-159, complete with standard Nos. 550.00 550.00 2,405.44 13,22,991.56
base, as required, complying to EN54 and LPCB/UL.
SITC of fault isolator Module with termination preferably after every 20–30 devices and
67 FA-5 shall be able to isolate electrical short circuit in the wiring etc. as required and Duly Approved Nos. 45.00 45.00 2,752.82 1,23,876.74
by EN54/LPCB/UL.
SITC of Analog Addressable Type Manual Call Point having Surface or flush mounting
Option fully complaint to EN54 having Rotary Decade Swicthes for Addressing from 01-99
complete with Back Box for Mounting Complete as required conforming to BS5839 Standards
and Duly Approved by EN54/LPCB/UL.
SITC of Sounder Cum Strobe complete with Mounting Base as required conforming to
BS5839 Standards and Duly Approved by EN54/LPCB/UL.
70 FA-8 SITC of Output control module for Lift,Ahu,pressure fan/Exast fan etc. Nos. 42.00 42.00 2,527.15 1,06,140.22
71 FA-9 SITC of input monitor module for FA panel intigration with fire fighting flow switch. Nos. 10.00 10.00 2,751.13 27,511.26
SITC of 2Core 1.5 Sqmm Copper Aromerd Cable FRLS including the cost of petty material
required to complete the work upto the entire satisfaction of Engineer In Charge.
Supply, Installation, Testing and commissioning of MOD bus Interface Gateway for
communication with BMS / Other Utilities. MODbus shall support minimum 12000 data points.
MODbus Gateway shall act as an independent node communicating on the peer to peer
73 FA-11 network and shall not be dependant on the Fire Panel CPU for operation. Failure of Fire Panel No 1.00 1.00 2,33,574.19 2,33,574.19
CPU shall not result in failure of MODbus Gateway. with 3 Year free comprehensive warranty
period including cost of petty material required to complete the work upto the entire
satisfaction of Engineer In Charge.
Part 3:- Fire and Smoke Extraction System - - -
Authorised Signatory
Contractor BOQ Page No. 40 NBCC
Digitally signed by RAHUL
Construction of balance internal work of Library Building at Chaudhary Ranbir Singh University, Jind, Haryana at the Risk and Cost of M/s. R and B Infra Project Pvt. Ltd.
Total Balance Qty. to Rate at which
Quantity be executed at item was
Description of Item Unit in Original Risk & Cost Awarded in
Tender original tender
Supply, installation, testing and commissioning of Ceiling hang Vane axial flow type
Fresh Air - exhaust air fan for basement ventilation of following capacity with powder
coated GSS casing and aluminium alloy impellers with high efficiency aero-foil sections,
blades, the impeller directly driven by TEFC induction motor (EFF- 2) and 'H' class insulation
suitable for 3 Phase, 50 Hz, 415±10% Volt, ac supply, suitable capacity of TP isolator with
M.S enclosure box complete as required and as per specifications. Fans should be AMCA
74 VS-1 certified for air & sound performance & should be statically & dynamically balanced upto G 2.5 - - -
as per ISO 1940 & AMCA 204/3 standard.The sound pressure should not exceed 80 db(A) at a
distance of 3 Mts. Fan and Motor for Fire exhaust fans shall be suitable for operation at
minimum 250 deg C for 2 hrs. (as per EN12101-3: 2002 CE certified). The contractor will
be provided one point TPN supply of desired rating at each floor & basement. The
Star Delta/DOL Electric starter panel as required for Auto start from fire alarm
input/output module/CO Analyser sensor via NO/NC contacts shall be in contractor
Supply, installing, testing and commissioning of Ductless Ventilation / Jet fans as
per specifications for normal ventilationand Smoke Extraction application. The complete fan
assembly withits Casing, impeller & motor shall manufacturer and certified as tested for 250
Deg C for 2 hours operation. The Jet fans casing shall be made Galvanized Steel. The unit
shall be complete with silencers andguard. The Motorshall be dual speed and run on the
electrical power suitable for415V/3 Ph/50Hz.. The Jet fan diameter shall be 315 mm. The Jet
fan shallbe as per technical specification and of approved make.(1.28/0.64 CMS),Noise level
should not exceed 45 DB in normal speed & 55 DB at full speed .
The contractor will be provided one point TPN supply of desired rating at each floor
& basement. The Star Delta/DOL Electric starter panel as required for Auto start
from fire alarm input/output module/CO Analyser sensor via NO/NC contacts shall
be in contractor scope at each floor.
Supply, installing, testing and commissioning of CFD (Computational Fluid Dynamics)
Analysis (for CO simulation)by using CFD software to model airflow caused by both air
movement equipment and convection from heated surfaces to be done by third party on extra
Supply, Installation, testing and balancing of powder coated MS Supply /Exhaust air
77 VS-4 grille with Double Louver & MS volume control damper complete with nuts, bolts, screws etc. Sqm. 4.00 4.00 13,073.13 52,292.52
as per drawings and specifications. (for Basement ventilation).
Supply, fixing and commissioning of Fresh/ exhaust air M.S louvers with section
comprising of powder coated Aluminium louvers & bird screen as per specifications.
Supply, installation & testing of GI back draught dampers similar construction of gravity
79 VS-6 louvers (Basement fans- fire case as specified in the drawing.), provided with suitable links to SQM. 4.00 4.00 10,231.15 40,924.58
prevent the back pressure of air.
Part 4 :- Public Addressable and Evacuation System - - -
Authorised Signatory
Contractor BOQ Page No. 41 NBCC
Digitally signed by RAHUL
Construction of balance internal work of Library Building at Chaudhary Ranbir Singh University, Jind, Haryana at the Risk and Cost of M/s. R and B Infra Project Pvt. Ltd.
Total Balance Qty. to Rate at which
Quantity be executed at item was
Description of Item Unit in Original Risk & Cost Awarded in
Tender original tender
SITC of 6W Recessed Ceiling speakers with following features:-Speaker Drive 6",
Complete Aluminium grille and Metal baffle, line matching transformer 100/70V line. Variable
wattage tappings of 6 / 3 / 1.5, Effective frequency range 110-15kHz (BS6840),
SPL@1m/1W=91dB, Peak SPL 97dB complete with necessary mounting hardware &
SITC of 10W Wall Mount Speaker with Frequency Response 150Hz - 15kHz, with Line
Matching transformer 100V. Variable tapping 10W/5W, SPL@1M/1W - 90dB, Peak SPL 98dB.
the cost of petty material required to complete the work upto the entire satisfaction of
Engineer In Charge.
Supply, Installation,Testing & Commissioning of Digital Voice Evacuation system for
8 Zones. The System shall meet the standards of BS EN54 - 32 & EN 60849. it should be
capable for the EVAC, Paging, PA and BGM functions. The Controller shall have SD card option
to store the EVAC and Alert Voice Message. The Controller shall have Speaker line supervision
82 PA-3 and amplifier auto changeover. The Controller shall have following features: Seperate Zone Nos 1.00 1.00 2,78,585.32 2,78,585.32
volume control at the front side of panel, Status indications on the Panel for EVAC,Fault
,AC,DC ,Fault,ALERT & Fireman mic, Zone capacity up to 96 Zones, 8 programmable Control
Input and output, Fireman Microphone with High Priority, THD<1%, Frequency response 80Hz
- 20kHz, Up to 1000 Record files, 100V Class-AB Speaker Output.
SITC of Remote Paging microphone with minimum 08 buttons and Busy/Hole
Indication. The Microphone Should be suitable for Desktop mounting.
Supply Installation testing and comisioning of 480W RMS Dual Channel Power
Amplifier with Switch power technology for power electricity saving, Separate PFC Design for
highest reliability, Separate Power Supply System. Amplifier shall have Following Features:
240W RMS per Channel, Amplifier Output 100V, Supply input AC 220 +/- 10% - 50/60Hz,
Short Circuit, Power, Tempreature, Overload Protection, Auto Cooling Fans. THD <0.1%,
Frequency Response 40Hz - 20kHz, AC & DC Fuse, SNR >89dB.
Supply Installation testing and comisioning of Professional CD/DVD player with USB
flash port & 19" Rack mount arrangement.
Supply Installation testing and comisioning of 19-inch Equipment Rack with
86 PA-7 standardized frame or enclosure for mounting multiple PA controllers, CD player, Amplifiers Nos 1.00 1.00 29,248.15 29,248.15
etc modules. Size 24U.
TOTAL NON SCHEDULE ITEMS
FOR : FIRE FIGHTING WORKS
(11). PROVISION FOR LOW VOLTAGE WORKS - - -
(I) HSR/DSR ITEMS - - -
Supply and erection of metal clad switches / B.D.Bs with rag bolts on wall or
1 on exisiting angle iron board/ pedstal including bonding to earth and necessary - - -
Truoke pole switch with nautral link 100 amp. 415 Volts. Each 6.00 6.00 8,625.53 51,753.18
Supply and erection of minature circuit breaker / isolator 240 /415 V. in the
existing distribution board including making necessary connections.
(a) (ii) SP MCB of 9 KA breaking capacity 6 amp. to 32 amp. each 144.00 144.00 140.51 20,234.09
HSR Supply and erection of pipe for wiring purposes including bends inspection boxes
31.21 etc. where necessary and painting as required.
(xv) Heavy gauge welded conduit pipe 20 mm dia 1.60 mm thickness on surface. meter 4,000.00 4,000.00 70.84 2,83,353.30
(xvi) Heavy guage welded conduit pipe 25 mm dia 1.60 mm thickness on surface. metre 4,000.00 4,000.00 87.48 3,49,912.80
Authorised Signatory
Contractor BOQ Page No. 42 NBCC
Digitally signed by RAHUL
Construction of balance internal work of Library Building at Chaudhary Ranbir Singh University, Jind, Haryana at the Risk and Cost of M/s. R and B Infra Project Pvt. Ltd.
Total Balance Qty. to Rate at which
Quantity be executed at item was
Description of Item Unit in Original Risk & Cost Awarded in
Tender original tender
HSR Supply and erection of PVC unsheathed copper conductor cable single core 1100 volts
31.40 grade in pipe of suitable size excluding cost and erection of pipe.
Supply and erection of double door sheet steel enclosures distribution boards suitable
HSR for MCBs and ELCBs etc. recessed in wall including bonding to earth with all labour and
31.41 material requared complete the job in all respect upto the entire satisfaction of the Engineer-
in Charge of the work.
Supply and erection of PVC conduit pipe ISI marked (Medium) recessed in wall /
6 ceiling etc. including cost of PVC bends, inspection box and all other material requiredto - - -
complete the job in all respect to the entire satisfaction of Engineer-in-Charge of work.
HSR S/E/T/C of Cat-6 cable in existing PVC Conduit / PVC Channel complete in all respect with
31.80. all labour and petty material required to complete the job in all respect
Supplying and installing following size of perforated painted with powder coating
DSR M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with
4.1 connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting
suspenders etc as required.
4.1.1 100 mm width X 50 mm depth X 1.6 mm thickness. metre 100.00 100.00 402.32 40,231.52
4.1.2 150 mm width X 50 mm depth X 1.6 mm thickness metre 250.00 250.00 448.80 1,12,200.30
4.1.4 300 mm width X 50 mm depth X 1.6 mm thickness metre 350.00 350.00 524.87 1,83,704.22
4.1.6 450 mm width X 50 mm depth X 2.0 mm thickness metre 300.00 300.00 591.64 1,77,492.00
4.1.7 600 mm width X 50 mm depth X 2.0 mm thickness metre 150.00 150.00 646.58 96,986.70
TOTAL HSR - 2011 (WITH LATEST AMMENDMENTS) & DSR - 2018 (WITH DISCOUNTED FACTOR)
FOR : ELECTRICAL WORKS
(II) NON SCHEDULED Items. - - -
Supplying and installing following size of G.I Raceways, in convenient sections, joined
9 LW-1 with connectors etc as required complete in all respect to the entire satisfaction of Engineer-in- - - -
LW-1.1 150 mm width X 38 mm depth X 1.6 mm thickness metre 1,250.00 1,250.00 1,248.78 15,60,978.75
LW-1.2 200 mm width X 38 mm depth X 1.6 mm thickness metre 690.00 690.00 1,446.35 9,97,980.47
LW-1.3 300 mm width X 38 mm depth X 1.6 mm thickness metre 375.00 375.00 1,830.91 6,86,592.94
LW-1.4 450 mm width X 38 mm depth X 1.6 mm thickness metre 190.00 190.00 2,601.10 4,94,209.57
Supplying and installing following size of G.I Raceway Junction Box with 2.0 mm
10 LW-2 thick SS cover Plate, in convenient sections, joined with connectors etc as required - - -
complete in all respect to the entire satisfaction of Engineer-in-Charge.
LW-2.1 150 mm X 150 mm X 38 mm depth X 1.6 mm thickness Each 300.00 300.00 1,299.50 3,89,848.50
LW-2.2 200 mm X 200 mm X 38 mm depth X 1.6 mm thickness Each 175.00 175.00 1,606.94 2,81,213.89
LW-2.3 300 mm X 300 mm X 38 mm depth X 1.6 mm thickness Each 100.00 100.00 1,957.69 1,95,769.45
LW-2.4 450 mm X 450 mm X 38 mm depth X 1.6 mm thickness Each 50.00 50.00 2,755.35 1,37,767.60
TOTAL NON SCHEDULE ITEMS
FOR : LOW VOLTAGE WORKS
Authorised Signatory
Contractor BOQ Page No. 43 NBCC
Digitally signed by RAHUL
Construction of balance internal work of Library Building at Chaudhary Ranbir Singh University, Jind, Haryana at the Risk and Cost of M/s. R and B Infra Project Pvt. Ltd.
Total Balance Qty. to Rate at which
Quantity be executed at item was
Description of Item Unit in Original Risk & Cost Awarded in
Tender original tender
(12). LIFT SYSTEM - - -
(I) NON SCHEDULED Items. - - -
Supply Installation testing & commissioning of 13 Passenger Machine Room Less
1 L-1 Gearless Elevator with 3 year free comprehensivie warranty period to be supplied and Each 4.00 4.00 22,33,904.80 89,35,619.21
installed in accordance with the following technical specifications:
Type and Capacity: Approximately 884 Kg, 13 Persons. Speed: 1.0 meter per second. Type
of Drive: A.C. Variable Voltage Variable Frequency with 16-Bit Microprocessor. Motor:
Permanent Magnet Synchronous Electric Traction Gearless Motor to be hoisted on guide rail
within the elevator Hoist way. Travel Approximately: 21 meters ( B+G+5 Floor ). Serving :
07 Floors 07 Stops 07 Openings 07 Levels [ All on the same side ]. Hoist way Available:
1950 MM [wide] x 1750 MM [deep] Clear Dimensions. Headroom Required: 4200 MM
beyond finished floor level of last landing. Pit Depth Required: 1600 MM below the finished
floor level of first landing. Car Size: 1600 MM [wide] x 1350 MM [deep] x 2200 MM Car
Enclosure: Constructed out of Bright Annealed Scratch Resistant Panels in Stainless Steel
Finish. Car Entrance: Center Opening Automatic Doors in of in Bright Annealed Scratch
Resistant Panels in Stainless Steel Finish with a clear opening of 900 MM [wide] x 2000 MM - - -
[high]. Hoist-way Entrance: Center Opening Automatic Doors in of Bright Annealed scratch
Resistant Panels in Stainless Steel Finish with provision of Emergency Key Opening at all
Landings with a clear opening of 900 MM [wide] x 2000 MM [high]. Door Operation:
Automatic D.C. Door Operation with adjustable Door Opening and Closing timings.
Control: Duplex Full Selective Collective Control with or without attendant
Operation Automatic. Power Supply: 415 Volts, 3 Phase, 50 Hertz Alternating Current. Fan
1 No. with 300 MM Sweep. Flooring 20 mm Recess for flooring of Granite / Marble of good
quality / Colour as approved by Engineer - in- charge. Lighting: Diffused LED Lighting in car.
Indicators: Digital Direction and Position Indicators in both car and at all landings. Call
Registration: White.
Other Features: Battery Operated Emergency Light with Rechargeable Battery, Battery
Operated Emergency Alarm with Rechargeable Battery, Adjustable Guide Shoes, Micro
Movement L.E.D. based Buttons, Hands Free Press and Speak Intercom with EPABX for three
way communication. Load Weighing device with overload Bypass feature Steel items, Door
Frames Sill Angles, Fascia Plates, Spring Buffers. Call registration: White, Automatic Phase
Reversal Device, System Capable of withstanding ± 10% Variation in Supply Voltage
Fluctuations, Lift Announcement System to announce floor levels in English language only,
304 grade Stainless Steel Handrail, Additional Car Gate Lock, Infrared Safety Curtain, Braille - - -
Fixtures, Nudging, Car Platform constructed out of Cold Rolled Grain Oriented Formed Sheets
of Steel, 2 Phase Device Fire Man Drive, Fire Man Switch at Main Lobby Landing Doors Fire
Rating for One hour only, Car False Ceiling in Stainless Steel Finish, Pit Ladder, Motor
compatible for 180 Starts Per hour. Autometic Rescue Device to bring the Elevator to a
nearest Landing in case of power failure, All Signal Fixtures will be in Stainless Steel Face
Plates Finish including the cost of all petty material required to complete the job upto entire
specifications of Engineer-in – charge.
Supply Installation testing & commissioning of 15 Passenger Machine Room Less
2 L-2 Gearless Elevator with 3 year free comprehensivie warranty period to be supplied and Each 1.00 1.00 25,36,413.51 25,36,413.51
installed in accordance with the following technical specifications:
Authorised Signatory
Contractor BOQ Page No. 44 NBCC
Digitally signed by RAHUL
Construction of balance internal work of Library Building at Chaudhary Ranbir Singh University, Jind, Haryana at the Risk and Cost of M/s. R and B Infra Project Pvt. Ltd.
Total Balance Qty. to Rate at which
Quantity be executed at item was
Description of Item Unit in Original Risk & Cost Awarded in
Tender original tender
Type and Capacity Approximately 1080 Kg, 15 Persons. Speed 1.0 meter per second.
Type of Drive A.C. Variable Voltage Variable Frequency with 16-Bit Microprocessor. Motor
Permanent Magnet Synchronous Electric Traction Gearless Motor to be hoisted on guide rail
within the elevator Hoist way. Travel Approximately 21 meters [B +G+5 Floor ). Serving
07Floors 07Stops 07 Openings 07 Levels [ All on the same side ]. Hoist way Available 1950
MM [wide] x 2450 MM [deep] Clear Dimensions. Headroom Required 4200 MM beyond
finished floor level of last landing. Pit Depth Required 1600 MM below the finished floor
level of first landing. Car Size 1600 MM x 1350 MM x 2200 MM. Car Enclosure Constructed
out rear Panel :- Stainless Steel Pannels in Etched ST 42 silver cloud finish. Side Panel :-
Stainless Steel Pannels in Hairline finish ST 2. Front Panel :- Stainless Steel Pannels in Hairline
finish ST 2. Car Entrance Center Opening Automatic Doors in of in bright annealed scratch
resistant panels in stainless steel finishing with a clear opening of 900 MM [wide] x 2000 MM
[high]. Hoist-way Entrance Center Opening Automatic Doors in of in bright annealed scratch
resistant panels in stainless steel finishing ) with provision of Emergency Key Opening at all
Landings with a clear opening of 900 MM [wide] x 2000 MM [high]. Door Operation
Automatic D.C. Door Operation with adjustable Door Opening and Closing timings
Control Duplex Full Selective Collective Control with or without attendant
Operation Automatic. Power Supply 415 Volts, 3 Phase, 50 Hertz Alternating Current. Fan
1 No. with 300 MM Sweep. Flooring 20 mm Recess for flooring of Granite / Marble of very
good quality / Colour as approved by Engineer - in- charge
Lighting Diffused LED Lighting in car. Indicators Digital Direction and Position Indicators in
both car and at all landings, Call Registration: White.
Other Features Battery Operated Emergency Light with Rechargeable Battery. Battery
Operated Emergency Alarm with Rechargeable Battery. Adjustable Guide Shoes. Micro
Movement L.E.D. based Buttons. Hands Free Press and Speak Intercom with EPABX for three
way communication. Load Weighing device with overload Bypass feature. Steel items, Door
Frames Sill Angles, Fascia Plates, Spring Buffers. Call registration: White. Automatic Phase
Reversal Device. System Capable of withstanding ± 10% Variation in Supply Voltage
Fluctuations. Lift Announcement System to announce floor levels in English language only.
304 grade Stainless Steel Handrail. Additional Car Gate Lock. Infrared Safety Curtain. Braille
Fixtures Nudging. Car Platform constructed out of Cold Rolled Grain Oriented Formed Sheets
of Steel. 2 Phase Device Fire Man Drive . Fire Man Switch at Main Lobby HR65- Traingular
Tube with Bent Ends-Silver Mirror Polish SS on two sides
Landing Doors Fire Rating for atleast One hour . Car False Ceiling in SS - Hairline Silver and
Painted Casablanca. Pit Ladder. Motor compatible for 180 Starts Per hour. Autometic Rescue
Device to bring the Elevator to a nearest Landing in case of power failure. All Signal Fixtures
will be in Stainless Steel Face Plates Finish including the cost of all petty material required to
complete the job upto entire specifications of Engineer-in – charge.
TOTAL NON SCHEDULE ITEMS
FOR : LIFT WORKS
(13). VRV/HVAC SYSTEM - - -
(I) HSR/DSR ITEMS - - -
Supply, installation, balancing and commissioning of factory fabricated GSS sheet
DSR metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter
16.12.1 dampers, vanes, hangers, supports etc. as per approved drawings and specifications of
following sheet thickness complete as required.
Authorised Signatory
Contractor BOQ Page No. 45 NBCC
Digitally signed by RAHUL
Construction of balance internal work of Library Building at Chaudhary Ranbir Singh University, Jind, Haryana at the Risk and Cost of M/s. R and B Infra Project Pvt. Ltd.
Total Balance Qty. to Rate at which
Quantity be executed at item was
Description of Item Unit in Original Risk & Cost Awarded in
Tender original tender
Supply, installation, balancing and commissioning of fabricated at site GSS sheet
DSR metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter
16.12.2 dampers, vanes, hangers, supports etc. as per approved drawings and specifications of
following sheet thickness complete as required.
DSR Supplying & fixing of powder coated extruded aluminium Supply Air Grills with
16.15 aluminium volume control dampers as per specifications.
DSR Supplying & fixing of powder coated extruded aluminium Return Air Grills with
16.16 louvers but without volume control dampers complete as required.
Supplying and fixing of following thickness duly laminated aluminum foil of mat finish
closed cell Nitrile rubber (Class "O") insulation on existing duct after applying suitable
5 adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self Sqm 957.00 957.00 589.10 5,63,772.91
adhesive nitrile rubber tape insulation complete as per specifications and as required.
16.23.1 19MM THICK
TOTAL HSR - 2011 (WITH LATEST AMMENDMENTS) & DSR - 2018 (WITH DISCOUNTED FACTOR)
FOR : VRV/HVAC WORKS
(II) NON SCHEDULED Items. - - -
(A) Supply of VRV/ VRF airconditioning system (equipments) : - - -
Supply, Installation, Testing & Commissioning of air cooled VRF system complete
for cooling and Heating operation with Inverter twin rotory / Scroll compressor
Technology based outdoor units With 2 compressor in each condensing/outdoor unit for
backup operation in case in one compressor failure, scroll/Rotary comresssors,Accumulator,
etc. and indoor units comprising various types of evaporative blowers,electronic expansion
valve , microprocessor based remote controls/corded remote for indoor units etc. complete in
all respect.Note:- Outdoor unit Location as per site. Combination of hermatically sealed
scroll/Roraty inverter compressor suitable for operation on R-410A complete with high/low
pressure cut-outs, oil pressure failure switch, fan motor, safety thermostat, overcurrent
relay,fusible plugs etc. and suitable for operation on 380-415V,3-phase, 50-Hz A.C. supply.
Lot-Accumulator, liquid and gas shut- off valves and solenoid vales/modulation valves with
fittings to interconnect compressor, condenser and evaporator coils. Unit should be capable of
autoadressing of Indoor units in case in failure of any indoor units.ISEER of Circuit/System
should not less than 5.8 as per ISHRAE conditions.
Supply of Cassette type decorative Indoor Units The unit shall be insulated with
sound absorbing insulation material. The unit shall be supplied with suitable decorative
7 HV-2 panel/Grills & resin net filter with Mold resistance. The unit shall be supplied with drain - - -
pump, decorative panel with filter media , drain hose, clamp metal, washer fixing plate,
sealing pads, screws, clamps, washer for hanging bracket & insulation for fitting.
HV-2.1 VRF 2.5TR 4-way Cassette/ 9 Cooling KW Nos. 6.00 6.00 55,223.26 3,31,339.53
HV-2.2 VRF 3.2TR 4-way Cassette/ 11.2 Cooling KW Nos. 1.00 1.00 57,435.57 57,435.57
HV-2.3 VRF 4.0TR 4-way Cassette/ 14 Cooling KW Nos. 108.00 108.00 58,836.49 63,54,340.38
HV-2.4 VRF 4.5TR 4-way Cassette/ 16 Cooling KW Nos. 34.00 34.00 62,953.67 21,40,424.63
Authorised Signatory
Contractor BOQ Page No. 46 NBCC
Digitally signed by RAHUL
Construction of balance internal work of Library Building at Chaudhary Ranbir Singh University, Jind, Haryana at the Risk and Cost of M/s. R and B Infra Project Pvt. Ltd.
Total Balance Qty. to Rate at which
Quantity be executed at item was
Description of Item Unit in Original Risk & Cost Awarded in
Tender original tender
Supply of Wall Mounted type Decorative Indoor Units The unit shall be
insulated with sound absorbing thermal insulation material. The unit shall be
8 HV-3 supplied with suitable decorative panel & resin net filter with Mold resistance. The - - -
unit shall be supplied with drain hose, clamp metal, washer fixing plate, sealing pads,
screws, clamps, washer for hanging bracket & insulation for fitting,With remote controller.
HV-3.1 VRF 1TR Hi-wall /3.6 Cooling KW Nos. 1.00 1.00 35,484.67 35,484.67
HV-3.2 VRF 2TR Hi wal/ 7.1 Cooling KW Nos. 2.00 2.00 38,929.91 77,859.82
Supply of Dcutable type Indoor Units The unit shall be insulated with sound
absorbing insulation material. The unit shall be supplied with suitable decorative panel &
9 HV-4 resin net filter with Mold resistance. The unit shall be supplied with decorative panel - - -
with filter media , clamp metal, Wired/wireless Remote,washer fixing plate, sealing pads,
screws, clamps, washer for hanging bracket & insulation for fitting.
HV-4.1 VRF 8TR High Static Ductable/ 28 Cooling KW Nos. 7.00 7.00 1,44,518.64 10,11,630.45
Supply of Double skin Floor mounted Air unit / Supply Air Unit comprising of
thermobreak aluminium section framework, outer skin of 0.6mm thick Precoated G.I sheet,
inner skin 0.6mm thick plain G.I sheet., 43mm non CFC PUF insulation, anti corrosive min. 6
row deep DX - coil ,SS-304 drain pan with 12mm nitrile insulation Fans section shall be
imported Kruger/ Nicotra make direct driven fan with EFF-2/ IP-55/ TEFC/ 3 Phase/ 4 Pole
motor, drive set compatible with VFD panel, Anti-vibration mounted, double skin flexible
canvass at mouth connection, 2 sets of EU-04 Box type , Fine Filter having efficiency 99%
down to 5 micron at inlet, Manual On/ Off Volume control damper at the supply air fan outlet
for balancing. The static pressure to be 50MM,with 180CFM per TR considering for Fresh Air
Supply of AHU KIT, AHU Controller and Floor mounted AHU of 2500CFM Capacity designed
with 50mm static pressure with 6 row coil designed at 180CFM per TR
Supply of AHU KIT, AHU Controller and Floor mounted AHU of 2000CFM Capacity designed
with 50mm static pressure with 6 row coil designed at 180CFM per TR
Supply of AHU KIT, AHU Controller and Floor mounted AHU of 1500CFM Capacity designed
with 50mm static pressure with 6 row coil designed at 180CFM per TR
HV-5.4 Wired/Wireless remote for each AHU unit Nos. 10.00 10.00 5,208.55 52,085.45
Supply of Celing suspended TFA unit connected with VRF system of 1235CFM with remote
controller and required accessories
Supply of Indoor connection kit or "y"/ "T" joints with set of Supply and return connection
Supply of outdoor connection kit or "y"/ "T" joints with set of Supply and return
connection Kit.
13 HV-8 Supply of Centralized Control System with LCD display. Nos. 2.00 2.00 1,11,399.47 2,22,798.95
(B) Installation of VRV airconditioning system of following items - - -
Installation, Testing & Commissioning of VRV systems including topping of gas per site
(i) R410A Gas charging in VRV System
Supply, Installation, Testing & Commissioning of Interconnecting refrigerant
pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation
15 HV-11 between each set of indoor & outdoor units as per specifications, all piping inside the - - -
room shall be properly supported with MS hanger.Exposed pipeing should covered with
UV cloth and should in clised M.S tray.
Authorised Signatory
Contractor BOQ Page No. 47 NBCC
Digitally signed by RAHUL
Construction of balance internal work of Library Building at Chaudhary Ranbir Singh University, Jind, Haryana at the Risk and Cost of M/s. R and B Infra Project Pvt. Ltd.
Total Balance Qty. to Rate at which
Quantity be executed at item was
Description of Item Unit in Original Risk & Cost Awarded in
Tender original tender
Supply, Installation, Testing & Commissioning of Covered cable tray with GI Sheet
cover for exposed piping for suitable size.
Providing and fixing rigid PVC piping complete with fittings, supports as per
17 HV-13 specifications and duly insulated with 6 mm thick closed cell nitrile rubber insulation - - -
exposed drain pipe should be covered with UV cloth.
Supply, fabrication, installation, and testing of Double Canvaas Connection for AHU
units complete in all respects to the entire satisfaction of Engineer-in-charge.
Supply, fabrication, installation, and testing of control cum transmission wiring of 2
19 HV-15 core x 0.75 sqmm copper in suitable conduits between indoor and from outdoor units to Rmt 1,115.37 1,115.37 167.98 1,87,363.76
centralized controller complete in all respects to the entire satisfaction of Engineer-in-charge.
TOTAL NON SCHEDULE ITEMS
FOR : VRV/HVAC WORKS
(15). LIBRARY MANAGEMENT SYSTEM - - -
(I) NON SCHEDULED Items. - - -
SITC of HOUSYS RFID READER Hands Free 100 :
• Frequency 13.56 MHz
• Reading Range 5 cm
• Communication Wiegand 26/34
• Led and Buzzer Indication
1 LMS-1 NAC CONTROLLER 250 SERIES Nos 1.00 1.00 2,18,150.35 2,18,150.35
• Events :60000
• Card Capacity: 54000
• Communication TCP/IP
• Connection ability: card reader, release button, fire alarm , door sensor, door lock
Authorised Signatory
Contractor BOQ Page No. 48 NBCC
Digitally signed by RAHUL
Construction of balance internal work of Library Building at Chaudhary Ranbir Singh University, Jind, Haryana at the Risk and Cost of M/s. R and B Infra Project Pvt. Ltd.
Total Balance Qty. to Rate at which
Quantity be executed at item was
Description of Item Unit in Original Risk & Cost Awarded in
Tender original tender
SITC of HF 150 Android based handheld reader, 13.56 MHz, android OS 5.1.1, Ram 2 GB,
ROM 16 GB, screen 4.0 inches, supports, GPRS, wifi, bluetooth, GPS, WCDMA and camera.
SITC of Library management system - I5 processor, 2 GB ram, 1 TB HDD, SMART LIB 500
3 LMS-3 management software, tag registration module, frequenc 13.56 MHz, read range - 5-10 cm Nos 1.00 1.00 8,07,963.66 8,07,963.66
with Emergency alert system, event and log management, report management.
SITC of UHF label tag Range 0 – 8 m, Chip: Alien Higgs-3 Antenna, Size: 70x17mm,
4 LMS-4 Supporting Protocol: ISO18000-6C / EPC frequency 13.56 MHz, material coated paper, Nos 5,000.00 5,000.00 274.69 13,73,450.00
complete in all respect.
SITC of SMART LIB 500 kiosk system , touch screen panel, with built in book issuing
feature, latest operating system, library management software
TOTAL NON SCHEDULE ITEMS
FOR : LIBRARY MANAGEMENT WORKS
(16). LIBRARY INFORMATION DISPLAY - - -
(I) NON SCHEDULED Items. - - -
Supply Installation , testing and commissioning of Supply of Display Information sytem
working on LAN ,55" Full HD 450 Brightness, Smart signage platform,built in 10w speaker x2,
1 INF-1 Connectivity Input VGA (D-Sub 15 Pin), DVI-D(HDMI Common), Display Port 1.2, HDMI1 Nos 5.00 5.00 1,53,755.61 7,68,778.07
Component/Composite, Stereo mini Jack, USB 2.0 x 1 Output DP1.2(Loop-out), Stereo mini
Jack External Control RS232C (In/Out) thru Stereo Jack, RJ47 Sensor IR, Ambient Light.
TOTAL NON SCHEDULE ITEMS
FOR : LIBRARY INFORMATION DISPLAY
(17). ACCESS CONTROL SYSTEM - - -
(I) NON SCHEDULED Items. - - -
S/I/T/C of Software for Acess Control System with following feature: Provides a
complete and fully functional hardware/firmware infrastructure for access control software
host systems. Enables the replacement of head end software without visiting the access
control panel, reducing change out costs. Stores a complete access control and configuration
database for up to 32 Reader Interfaces (up to 64 doors) and250,000 cardholders. Connects
to the host and other devices on a TCP/IP network. Transactions event buffer max 99,999
Receives and processes real-time commands from the host software application. Reports all
activity to the host; report + supervised inputs /alarms with 255 priorities. Provides fully
functional offline operation when not actively communicating with the host access control
software application,performing all access decisions and event logging.
Supply , Installation and commissioning of 2 Door Controller, Stores a complete access
control and configuration database for up to 2 Reader Interfaces (up to 2 doors) and 250,000
2 ACS-2 cardholders, Connects to the host and other devices on a TCP/IP network, Interface for two Each 1.00 1.00 20,198.17 20,198.17
Wiegand or Clockand-Data readers; inputs for 2 door monitors, 2 REX switches, AC
fail,Battery fail and Tamper complete with power supply & enclosure.
Supply, installation, testing, commissioning of Recessed/Surface mounted short
Range Weigand (26/32/34 bit) reader . The reader shall seamlessly integrate with
controllers to activate and deactivate the locks. The reader shall have an operating frequency
in the 13.56 MHz card range.
4 ACS-4 Supply , Installation and commissioning of 600 LBS Each 1.00 1.00 4,766.93 4,766.93
5 ACS-5 Supply of Providing of Smart Card 16K, 16 application area. Each 200.00 200.00 216.58 43,316.50
Authorised Signatory
Contractor BOQ Page No. 49 NBCC
Digitally signed by RAHUL
Construction of balance internal work of Library Building at Chaudhary Ranbir Singh University, Jind, Haryana at the Risk and Cost of M/s. R and B Infra Project Pvt. Ltd.
Total Balance Qty. to Rate at which
Quantity be executed at item was
Description of Item Unit in Original Risk & Cost Awarded in
Tender original tender
Supply , Installation and commissioning of Break Glass Unit shall be resettable
6 ACS-6 type and must approved for installation it should clearly indicate " Emergency door release Each 1.00 1.00 2,018.97 2,018.97
break glass" or similar to this to accurately define the purpose of it .
Supply , Installation and commissioning of Visual & Audiable notification device for
emergency opening condition to identify the door with emergency conditions.
Supply , Installation and commissioning of Manual Overriding Switch on intrnal side
of the clean room along with the proximity card reader.
9 ACS-9 Supply , Installation and commissioning of 22 G- 4 Pair coper cable. Rmt 500.00 500.00 120.44 60,220.50
TOTAL NON SCHEDULE ITEMS
FOR : ACCESS CONTROL SYSTEM
Authorised Signatory
Contractor BOQ Page No. 50 NBCC
Digitally signed by RAHUL
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
CRSULibraryNITR1.pdf
Tender Document
GCC2019with1to5amd.pdf
Tender Document
CS_cover_2_2Quotingsheet.xlsx
Tender Document
SCCR1.pdf
Tender Document
TechnicalSpecs.pdf
Tender Document
BOQPackage1.pdf
Tender Document
ApprovedMakesprebid.pdf
Tender Document
soilinvestigationreport.pdf
Tender Document
7CRSULibraryDrawings.pdf
Tender Document
11NAnnexureIAPhysicalMilestones.pdf
Tender Document
corrigendum-1968-corrigendum01.pdf
pdf • 0.08 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .