Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹63.1 LAdmitted-Finance E3 172 ARERA COLONY NEAR 10 NO MARKET ARERA COLONY BHOPAL MADHYA PRADESH 462016 | BHOPAL | MADHYA PRADESH | 462016 | -7.57% | ₹63.1 L | L1 | Admitted-Finance |
| 2 | L2₹66.7 L+₹3.6 L (5.76%)Admitted-Finance | -2.25% | ₹66.7 L+₹3.6 L (5.76%) | L2 | Admitted-Finance |
Tender Value
₹68.3 L
EMD Value
₹1.4 L
Closing Date
17 Aug 2026, 6:00 pmClosed
GM RSRDC LTD JAIPUR
GM RSRDC LTD SETU BHAWAN, JHALANA DOONGARI JAIPUR
HVAC work RTO Jaipur-II at Transport Nagar Scheme Sikar Road Jaipur
2026_RSRDC_585194_1
RSRDCC NIT 298/2026-27 Dated 07.08.2026 Sl No 02
Open Tender
Electrical Works
Percentage
365 days
Transport Nagar Scheme Sikar Road Jaipur
please refer tender document
2 documents required · 2 mandatory
₹1,180
PD RSRDC ELECT-I JAIPUR THROUGH NEFT/RTGS/IMPS
₹1.4 L
21 Aug 2026
10 Aug 2026
18 Aug 2026
10 Aug 2026
17 Aug 2026
11 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | HVAC | 0 | Each | 0 | ₹0 |
| 2 | Supply, Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having 100% hermetically sealed inverter type Scroll Compressor(s) with and minimum two compressors along with two Condensing fan, above 14/18 HP modules, microprocessor based Controller, Side / top discharge type condensing unit(s), with R-410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The EER at 100% load with AHRI conditions shall not be less than 3.5 and Including OEM supplied Piping connection Kit etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . | 90 | per HP | 24,270 | ₹21,84,300 |
| 3 | Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, Corded remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down valve in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. (Make will be same as of Outdoor). All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . | 0 | Each | 0 | ₹0 |
| 4 | 1.6 TR | 14 | Each | 56,785 | ₹7,94,990 |
| 5 | 2 TR | 11 | Each | 58,230 | ₹6,40,530 |
| 6 | 2.4 TR | 2 | Each | 64,943 | ₹1,29,886 |
| 7 | 4 TR | 4 | Each | 69,278 | ₹2,77,112 |
| 8 | Supply, installation, testing and commissioning of following minimum capacity VRV/VRF High wall type Indoor unit equipped with and comfort washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitable for operation on 230 V ± 10%, 50 Hz, single phase AC supply, complete as required. The unit shall have automatic force shut down valve in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. (Make will be same as of Outdoor) All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . | 0 | Each | 0 | ₹0 |
| 9 | 0.6 TR | 3 | Each | 34,478 | ₹1,03,434 |
| 10 | 1.0 TR | 2 | Each | 35,572 | ₹71,144 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.33 MB
agrement.pdf
Tender Documents • 0.45 MB
BOQ_1039614.xls
BOQ • 0.30 MB
AnnexureABCD_RTPPAct2012_AnnexureC.pdf
Tender Documents • 0.10 MB
AnnxAPWDELECTBSR2022.pdf
Tender Documents • 0.44 MB
EligibilitycriteriaofBiddersforqualifyinginTechnicalBid.pdf
Tender Documents • 0.59 MB
Engineering_Cost.pdf
Tender Documents • 0.68 MB
gentcalongwithdlptc-hvacRTO.pdf
Tender Documents • 0.43 MB
projectdirectorbankaccountnumberdetails3_4.pdf
Tender Documents • 0.48 MB
various_Circulars_orders.pdf
Tender Documents • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .