Tender Value
Refer Docs
Closing Date
28 Jan 2022, 6:00 pmClosed
Manager-Admin (Purchase)
CDAC Innovation Park Pune 411 008
Carrying out Interior/Civil Work, electrical and Allied HVAC Work for creation of Infrastructure on turn-key basis at CDAC Pune
2022_DIT_667392_1
CDACP/LnB-Nasscom/21-22/339
Open Tender
Civil Works - Others
Works
120 days
Pune
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,500
CDAC
Exempted
ONLINE
18 May 2022
7 Jan 2022
31 Jan 2022
8 Jan 2022
28 Jan 2022
21 Jan 2022
10 Jan 2022 - 14 Jan 2022
14 Jan 2022
Amount
Interior & Furnishing Work -
Providing first class Burnt Brick masonry with conventional /I.S. type bricks in cement mortar 1:4 including scaffolding, racking out joints pointing in C.M. 1:3 and watering in pillars of rectangular or square shape as shown on the drawing or as directed etc.complete.
Providing rough cast cement plaster externally in two coats to concrete, brick or stone masonry surfaces in all positions with base coat of 12 to 15 mm thick in C.M. 1:4 and rough cast treatment 12mm thick in proportion 1:1 1/2:3 including scaffolding and fourteen days curing complete.
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate20 mm nominal size derived from natural sources).The rate shall be inclusive of required reinf.steel, shuttering etc.
Providing and applying BIRLA putty of average thickness 1 mm or more than 1mm as required to make surface smooth , of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Providing and applying plastic emulsion ( luster) paint of approved quality,colour and shade to old and new surfaces with one coat of primer and two coats plastic emulsion ( luster) paint including scaffolding, preparing the surface. etc. complete.
Solid Core Flush door Double leaf- Providing and fixing factory made solid core flush door shutters in double leaves 35 mm thick, decorative type of exterior grade 1.5mm laminate on both side,as per detailed drawings ,conforming to I.S.:2202–1966(Revised )including approved face veneers on both sides,without glazing and venetians including mat finish stainless steel fixtures and fastening,stoppers and finishing with french polishing etc.(Excluding door frame)(Sample to be got approved from Engineer before use)Commercial Hard Wood shutter. The Vision Panel with clear glass of 300x 300mm dia to be provided in each door. (Note -For Distribution panel area door vision panel should not be provided)
Providing and fixing Jungle (hard) wood of approved species joists and girders in timber floor of single,double or framed type including scaffolding if necessary and one primer coat etc. complete.
Providing and fixing Hydraulic door closers
Providing & Fixing in position, Acoustical Panelling made from 12mm w p Plywood & 1.5mm laminate on both side, 50x50mm teak wood of 600x600c to c having teak wood supports from wall of required length, in front of 1000 Gsm synthetic wool 50mm thick with chicken mesh on wall side, including cost of required Cut-Outs, decorative mouldings/ finishing-items / pain & Scaffolding, as per Architectural & Acoustical Design & Instructions & Complete in all aspects. including all materials labour, finishing etc complete. Laminate to be of Merino(Micro line) range. (Note-From FFL to bottom of slab ht is 3.43 m. The laminate to be considerd only upto false ceiling height from FFL)
Providing & Fixing in position Acoustical Panelling , partly laminated partly glaze ( finished in laminate on both the sides for part area and toughened glass 12mm thk. as per design fixed onto the partition with 12 mm thk tw beading with PU paint matching in color and finish to the laminate) Acoustical Panelling made from 12mm w p Plywood & 1.5mm laminate on both side, 50x50mm teak wood of 600x600c to c having teak wood supports from wall of required length, in front of 1000 Gsm synthetic wool 50mm thick with chicken mesh on wall side, including cost of required Cut-Outs, decorative mouldings/ finishing-items / pain & Scaffolding, as per Architectural & Acoustical Design & Instructions & Complete in all aspects. including all materials labour, finishing etc complete. Laminate to be of Merino(Micro line) range.(Note-From FFL to bottom of slab ht is 3.43 m. The laminate to be considerd only upto false ceiling height from FFL)
Column cladding with teak wood frame, finished in laminate Fluorescent. The t.w. frame 2" x 1 1/2" @ 1'6"x1'6" grid covered with 6mm comm. Plywood on the outer side (no plywood required on inside partion). The approved colour fluroscent laminate matching with existing laminate colour of minimum 1 mm thickness shall be used.
Providing and Fixing Vertical Blinds of approved Make and shade of 100mm regular fabric with powder coated aluminium channel with telting PVC chain & bottom weight plate with all necessary fixtures and fitting etc. complete. (Sample to be final by Engineer In-charge prior execution of work)
Providing and fixing 12mm toughned glass door with required fixtures and fittings etc completed
Providing and laying vitrified mirror/glossy finish tiles decorative type having size 590mm to 605mm x590 mm to 605mm of 8 to10 mm thickness and confirming to IS.15622-2006 (groupBla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling .including grouting the joints with white cement and matching pigments , curing and clearing etc. complete etc. complete.
Removing wooden or A.C. partition including frame work and stack-ing the materials as with all leads, lifts etc. complete
Dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead
Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge
Cutting and Removing cement tiles or vetrified tiles or marble or polished shahabad floor or dado with out bed concrete as per project quirement including removal of cement mortor, stacking the materials as directed with all leads, lifts etc. complete.
Demolishing brick work in cement mortar manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
Providing and fixing in position Gypsum board false ceiling with 12.5 mm thick Gypsum boards, screwed/fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete.
Supply & fixing of acoustical mineral fiber board (Dune-ML-RH-99) false ceiling of Armstrong/AMF or equivalent make system with 15 mm Silhouette (BR) grid quick hook suspension system having main tee 3000mm long x 38 mm web height x 15mm wide silhouette (BR) sections. The main runner is to be fixed with 4mm thick pre-stretched GI wire with soffit clear & GI Rawl plug inserted on the main roof to be fixed at 1200 mm c/c. The last hanger at the end of each main runner should not be grater than 450 mm from the adjacent wall. The main runner will be at the distance of 1200 mm c/c. The 1200 mm x 38 mm x 15 mm silhouette (BR) wide cross tee sections, having an integrally formed hook nose with precise butt cut joint end is to be fit in between the main tee at a distance of 600 mm to make a module of 1200mm x 600mm. Another cross tee having an integrally formed hook nose with precise butt cut joint end of size 600 mm x 38mm x 15mm is to be fitted at 1200 mm sections parallel to main tee at 600mm centre to make a square grid of 600 mm x 600 mm. All base frame material should be made of good quality galvanized steel. It should have a capping of material coated with baked polyester paint. The shadow molding perimeter angle white coloured secured at 450 mm c/c is to run all along the peripheral, Prime Dune, RH-99 per painted tiles, microlook, 15 mm thick suitable for 600mm x 600mm grid to be placed on grid. Tiles should have NRC of 0.50, STC of 34 dB, having light reflection of 85% or more & thermal conductivity K-0.052-0.057W/sq.m/ degrees centigrade. The fire rating of tile should be class 0 for fire propagation & class I for spread of flames as per BS 476 & having humidity resistance of 99% RH. The board should have a density of 240-260 kg/Cubic meter. The rate should include for cutout for AC grills, fire sprinkler & light fixtures, additional members if required is to be provided into the grid system. The work has to be done as per the direction of Engineer-in-charge.
FIRED RATED DOUBLE DOOR as per IS 3614 Part2 & BS476 Part 20 & 22, tested to UL10 Cand conforming to NFPA80, testedat NTL / CBRI / ARAI - Double leaf 2 hour fire rated Entrance door frame and leaves shall be made from galvanized steel 46mm thick fully flush, door shell in specially designed honeycomb structure for reinforcements & 1 hour fire rated vision glass of size 300 mm X 300 mm. Door will be primed with zinc-phosphate stoving primer and finished with epoxy paint as required, complete with all accessories like door closer, handle, lock etc. All door shall be provisioned with GI frame required .
WorkStation and Allied Work - Modular Linear Workstation of Size 1200(L)X600(W): Supply and installation of above workstations with minimum 70 mm thick 1200 mm high panels as partition(Sample Drawings are attached). With combination of two separate metal raceways for data and power at bottom, two intermediate fabric blocks, top tile - white board, fabric magnetic. The 25mm thick Pre- laminated particle board support for top resting at both end of workstation shall be provided . The table should be complete with suitable keyboard holder tray. The cutouts for 6 Module for power and 2 Module for network point has to be there . The cable grommets should be there on table top for routing of power and data cables. The sample shop drawing has to be approved by client before delivery. Note:- 1) Material of table top:- Work top should be made of 25mm thick Pre-laminated particle board. 2) Material for tiles for top: Fabric magnetic (over GI sheet) plus white board 3) Material of bottom tile: Metal tile (GI Sheet) 4) Plain edge banded with 2mm PVC tape 5) Frame of the workstation: Powder coated extruded Aluminium sections.
Supply and installation of Top supporting pedestal with flat metal front of total size 390w x 585d x 700 ht, 3dr = 2 box + 1 file, central locking. Note - 1) The top supporting pedestal should be from the same OEM of modular workstation. 2) The material of pedestal shall be CRCA / GI sheet of minimum 0.6mm thickness in power coated finish as per approved colour.
Providing and fixing Motion Mid back office chair with suitable caster wheels, Contact-Tilt Mechanism , Seat Height Adjustable, Adjustable arm rest, Mesh back fabric, lumbar back support. Finish colour –Black. PU foam cushion seat. Note - 1) The chair should be from the same OEM of modular workstation 2) The chair is required with cushion seat assembly consists of seat base moulded in glass-filled ply-amide moulded in HR Polyurethane foam density 45 ± 2kg/ m3
Providing & fixing Gain storage unit -2100 H x 500W x 500D and Gain overhead unit 650H x 500W x 500D with metal door,Lock & key.The gain storage unit should be power coated , colour of powder coating should be as approved by client..Make-Godrej or equivalent make as approved by client.
Class Room and Allied Work - Providing and fixing Platform inside classroom of Siz 4.5m x 1.2m x .3m (height) with 18mm plywood ( supported by plywood vertical support in-between as required etc. complete)laid over it as directed by Engineer-in-charge
Providing and fixing White board of size-8' x 4 ' with an heavy duty aluminium frame of size for class room.
Modular Linear Workstation of Size 1200(L)X850(W): Supply and installation of above workstations with minimum 70 mm thick 950 mm high panels as partition(Sample Drawings are attached). With combination of two separate metal raceways for data and power at bottom, two intermediate fabric blocks, top tile - fabric tackable, white board, fabric magnetic. The table should be complete with suitable keyboard holder tray. The cutouts for 6 Module for power and 2 Module for network point has to be there . The cable grommets should be there on table top for routing of power and data cables. The 25mm thick Pre- laminated particle board support for top resting at both end of workstation shall be provided. The sample shop drawing has to be approved by client before delivery. Note:- 1) Material of table top:- Work top should be made of 25mm thick Pre-laminated particle board. 2) Material for tiles for top: Fabric magnetic (over GI sheet) plus white board 3) Material of bottom tile: Metal tile (GI Sheet) 4) Plain edge banded with 2mm PVC tape 5) Frame of the workstation: Powder coated extruded Aluminium sections
Providing and fixing Motion Mid back office chair with suitable caster wheels, Contact-Tilt Mechanism , Seat Height Adjustable, Adjustable arm rest, Mesh back fabric, lumbar back support. Finish colour –Black. PU foam cushion seat. Note -The chair should be from the same OEM of modular workstation.
Providing & fixing Student chair -Made up of round pipe with na Black powder coating.The seat and back support with cushion with standard fabric.The seating cushion 2 inch and back support width 1 inch cushion.Sample to be approved by CDAC engineer before delivery.
Providing and fixing ,Modular conference room table -Godrej Talk Conference table or equivalent ,seating capacity 8 seater laminate finish,Colour -brown. -The leg shall be Nickle chrome plated. -Sufficient Access flap to have easy access to the plug points. -Inclusive of Pop Box(Power & Data point) -Table should have Concealed wire management system under the table. Make-Godrej or equivalent make as approved by client. Sample drawings to be approved before delivery.
Providing and fixing Motion Mid back office chair with suitable caster wheels, Contact-Tilt Mechanism , Seat Height Adjustable, Adjustable arm rest, Mesh back fabric, lumbar back support. Finish colour –Black. PU foam cushion seat. Note -The chair should be from the same OEM of modular workstation
ELECTRICAL ,FIRE ,PA AND ALLIED WORKS - A) MAIN LT PANEL / DB'S -
Supply and installation of 8-way, VTPN, Metal type, with Plain / Transperant Door (As approved by client / consultant / architect), UPS Power Distribution Board (UPS MainDB-to UPS room DB) (for desks), surface / flush mounted on wall, interconnected wiring complete with earthing lugs, including DB wiring dressing with ferruling, termination of circuits with ping type copper lugs, blank plates, etc. housing following switchgears : (Schneider / Hager / Siemens / Legrand make as approved by client / consultant) a) 1 no.,100A, MCCB, "C/D" curve type 25kA, MCCB with Thermal Magnetic release, of approved make with over load (O/L), short circuit (S/C) & Earth Fault (E/F) protection. The Breaker shall be suitable for 415 Volts 50 Hz., AC supply. The breaker shall have breaking capacity of 25kA for 1 Sec. as required. (Schneider / Hager / Legrand / Siemens / L&T make)as incomeras b) 8 nos, 63A,TP , MCB, "C/D" curve type as outgoings Full set as above.
Supply and installation of 8-way,SPN, Metal type, Double Door (As approved by client / consultant / architect) UPS /Raw Power Distribution Board, surface / flush mounted on wall, interconnected wiring complete with earthing lugs, including DB wiring dressing with ferruling, termination of circuits with ping type copper lugs, blank plates, etc. housing following switchgears : (Schneider / Hager / Siemens / Legrand make as approved by client / consultant),I/C-32 A DP MCB,6 Numbers 10/16 AMP SP MCB as Outgoings
Supply & Installation of 25/32A, DP, MCB, box with 20A, metal clad / modular plug-socket including power circuit of (4/6 sq.mmX3core) copper flexible wires directly taken from the relevant Raw/AC DB through PVC conduits for room CASETTE /SPLIT A/C including all necessary hardware & accessories, etc. (Schneider / Hager / Legrand / Siemens / L&T make)
ELECTRICAL & ALLIED WORKS - CABELS / MAINS Supply & Installation of 1100V grade armoured cable having sector / circular shaped aluminium / copper conductor PVC insulated cores, laid up, PVC tape wrappe d inner sheathed, GI strip / wire armoured and overall extruded PVC sheathed confirming to IS: 1554, laid on wall / ceiling using GI clamps & spacers as per route shown at site and further as directed by Consultant at site in the following sizes :- (Make - Polycab / Finolex / RR / Havells) NOTE :- All Armoured cables shall be provided with temporary labelling at every 5mtrs & then finally with metal indentification tags showing the size & the location from/to the respective Panel / DB, at both the ends.The rate should include terminations at both ends with suitabls lugs and glands as applicable
4C x 10 Sq.mm Copper Armoured cable with 2 runs of 12 SWG GI bare wire(UPS DB)
4C x 16 Sq.mm Copper Armoured cable with 2 runs of 12 SWG GI bare wire (AC DB)
3C x 6 Sq.mm Copper Armoured cable with 2 runs of 12 SWG GI bare wire(UPS DB)
4C x 50 Sq.mm Aluminium Armoured cable with 2 runs of 12 SWG GI bare wire (Main Panel /DB)
WORKSTATION UPS POWER WIRING Supply & Installation of concealed / ressessed UPS point wiring using 600V 3R (P+N+E) x 1.5 Sq.mm copper conductor PVC insulated wires (with proper R,Y,B color code) pulled through already laid PVC raceway on walls and through table partition including 3R (P+N+E) x 2.5 Sq.mm circuit wires from the relevant DB and also including 2.5 sqmm green color copper earth wire and approved make modular type switch plate, switches, MS concealed back box, etc. as required & as approved by the consultant. (The item rate shall include Lighting / Raw / UPS Power Circuit wiring from relevent DB to the switch board with 3Rx2.5 Sq.mm wires & from switch board to next switch board OR to the first light point / primary point / full point) NOTE :- 1. Only PVC insulated wire shall be used; 2. Conduit carrying circuit wiring should not carry point wiring and Conduit carrying point wiring should not carry submain/circuit wiring; 3. Flexible conduits & Elbows are not allowed; 4. The wires from ceiling junction to light points / light fixture shall be drawn in flexible PVC conduit with adptor & cover for junction box & crimp type lugs at both the ends alongwith necessary hardware & accessories, etc. as required; 5. Proper ferrules, lugs, must be used in all cabling and wiring on both load / source end; 6. Each switch board must be provided with respective ferrules representing the respective DB, Phase & Circuit numbers; 7. Looping of Neutral / Earth wire between two seperate Primary / Full Points is strictly not allowed; 8. Looping of Neutral / Earth wire between two seperate circuits on similar or other phase is strictly not allowed; 9. Ferulling / numbering / taggning to wires with circuit number & db name for all lighting & raw / ups power shall be strictly followed at both DB & switch board / switch socket boards ends.
Supply & Installation of primary point wiring for UPS or stabilized power plug points on workstations / table for computers using 3C X 2.5 Sqmm copper conductor PVC sheathed white color flexible cable pulled through already laid Surface PVC Box raceway and table/workstation partition raceways and taken upto table top using PVC rigid or flexible conduits run within wooden/metal partitions. Each point consisting of 2 nos of 5A , 3 pin sockets above table top/bottom & 1 No., 15A Switch above table top, wired together forming one point. The earth wire of 3 core flexible cable to be of yellow-green color only. (3 no.s desks served by one circiut from DB)
Supply & Installation of Secondary point wiring for UPS or stabilized power plug points on workstations / table for computers using 3C X 1.5 Sqmm copper conductor PVC sheathed white color flexible cable pulled through already laid tablepartition raceways and taken upto table top using PVC rigid or flexible conduits run within wooden/metal partitions. Each point consisting of 2 nos of 5A , 3 pin sockets above table top/bottom & 1 No., 10/15A Switch above table top, wired together forming one point. The earth wire of 3 core flexible cable to be of yellow-green color only. ( Maximum 4 no.s desks to be looped from each primary UPS point from first desk as per instruction for staff area and Maximum two point to be looped from each primary UPS point from first desk for all classrooms )
ELECTRICAL & ALLIED WORKS - WALL PVC -RACEWAYS
Supply and laying PVC Raceways with cover, & two cable compartment for UPS Power Circuit Cable and Data cables a) 75 x 75 x 1.6mm thick PVC Raceways with cover
ELECTRICAL & ALLIED WORKS - LIGHTING POINTS IN ROOM, Supply & Installation of concealed / ressessed / surface light point / fan point / call bell point wiring using 600V FRLS grade 3R (P+N+E) x 1.5 Sq.mm copper conductor PVC insulated wires (with proper R,Y,B color code) pulled through heavy gauge PVC conduits laid concealed over false ceiling or in wall chases or on the ceiling in case of an open ceiling including 3R (P+N+E) x 2.5 Sq.mm circuit wires from the relevant DB and also including 2.5 sqmm green color copper earth wire and approved make modular type switch plate, switches, MS concealed back box, etc. as required & as approved by the consultant. (Each circuit shall not feed more than 8 points OR 800 watts as per following configuration.) (The item rate shall include Lighting / Raw / UPS Power Circuit wiring from relevent DB to the switch board with 3Rx2.5 Sq.mm FRLS wires & from switch board to next switch board OR to the first light point / primary point / full point)
Primary light points including the cost of 5A switch
Secondary light points looped from the above point(maximum 3 points looped from one primary)
Supply & Installation of (26-32W) (2' X 2') full lit panel type LED Light fixture.,CRI >80,The fitting shall be suitable for grid / plain ceiling type & surface mounted / to be hanged from the ceiling at the height approved by architect. (CGL , PHILIPS WIPRO , GE or equivalent category & model as approved by client / architect / consultant.)
Supply & Installation of (12 W) LED Spotlight/Down light flush mounted Light fixture. (CGL , PHILIPS WIPRO , GE or equivalent category & model as approved by client / architect / consultant.)
ELECTRICAL & ALLIED WORKS - DATA NETWORKING
Supply & Installation of Modular Data point including approved make Cat - 6 UTP cable through already laid trenches, and new flexible conduit in table partion ,RJ45 information outlet face plate, etc. with Termination, Testing and Documentation of UTP Points complete as required.(D-Link or equivalent)
Supply & installation of 24 Port 1 Gbps(Minimum) Unmanage switch including crimping complete in all respect etc. with both ports for Ethernet and Fibre Uplinking(D-Link or equivalent)
Supply & installation of 24 port jack panel in existing network rack(D-Link or equivalent)
Supply of mounting patch cord (3 feet')
Supply of mounting patch cord (7 feet')
Supply & Installation of 12 U floor/wall mounted network rack including all necessary hardware, accessories, etc.
Supply & Installation of 42U floor mounted network rack including all necessary hardware, accessories, etc.
Supply & laying of approved make Cat - 6 UTP cable through PVC conduits,with Termination, Testing and Documentation complete as required for uplinking(D-Link or equivalent)
Supply & laying of approved make LC to LC Duplex MMF OM3(50/125) Fibre Patrch Cord through PVC conduits,with Termination, Testing and Documentation complete as required for uplinking(Commescope or equivalent)
ELECTRICAL & ALLIED WORKS - PA SYSTEM
SITC of Speaker wire (through PVC conduit) from amplifier upto speaker
SITC OF Speaker 6 watt ( make-BOSCH / AHUJA) or equivalent make
Supply, Installation & Testing of Amplifier ,60 watt,for Classroom Address System suitable to operate on 230V A.C. / 12V D.C. supply with two low impedence microphone input, tone control, protection circuit complete for the speakers output lines. (Ahuja / approved equivalent make)
A compact & reliable single channel VHF Wireless Microphone AWM-520VL. It features a tie-clip microphone with a VHF high band body-pack transmitter and a sensitive noise squelch receiver. Single channel VHF wireless microphone available in six different frequencies. Electrect condenser unidirectional microphone. Transmitter has an on ON/OFF switch and a LED for ON indication. Stylish table-top receiver with a telescopic antenna & noise squelch circuitry.Power ON/OFF switch and output volume control on the front panel.1/4" (6.3mm) phone jack for audio output on the rear panel of the receiver. Microphone operates with 1×9V battery. Receiver operates on 9V DC through an AC adaptor, supplied along with the microphone.
ELECTRICAL & ALLIED WORKS - FIRE ALARM SYSTEMS
Supply, installation, testing and commissioning of Response indicator for all existing detectors located above false ceiling (The above ceiling detectors are already installed.The integration of RI with detector and existing repeater/ main fire panel is in vendor scope).
Supply, installation, testing and commissioning of Analogue Addressable Fault isolator module capable of monitoring shorted loop circuit and automatically restore communication when shorted conditions are corrected.
Supply, installation, testing and commissioning of Addressable Control Relay Module
Fixing of existing installed UL Listed Sprinkler Flexible drop pipes made of Corrugated SS Tubing to with stand 16 Bar pressure connected with Pendant type 15mm dia CP gunmetal / brass sprinkler head with all necessary required support accessories with false ceiling framing work. (Note -All the necessary fitting like rosette plate,support, nut bolt etc in vendor scope)-1000 mm long
Supply, installation, testing and commissioning of Addressable Single action Manual pull station having an integrally mounted addressable moudle that monitors and reports contact status.
SITC OF Hooter -addressable digital type with required Hooter operating voltage 12V/24V/220 volt, wiring And allied required accessories.
SITC OF FRLS Fire CABLE 2 X 1.5 Cu armoured cable
FIRE SUPPRESSION SYSTEM for HUB Room
Designing, supply, installation, testing & commissioning of CCOE certified 34/40 L capacity. Seamless cylinders with valve assembly & protection cap, pressure gauge, Safety burst disc and with low pressure supervisory switch for NOVEC 1230 gas installed on cylinder valve with Cylinder Pressure Operated Head with Hose & accessories, install on the Cylinder Valve cylinder support arrangements etc. complete.. Make: Kidde or equivalent
Supply of OEM Factory Filled NOVEC 1230 Gas.
Supply, installation, testing & commissioning of 24 VDC- 2.0 amps, Resettable, Electrical cum Mechanical actuator for NOVEC 1230 Cylinder with Cylinder Support Assembly, floor mounted, Flexible rubber discharge hose, with braided reinforcement Make: Kidde or equivalent.
Designing, supply, laying & fixing/ installation of the NOVEC 1230 piping will be, as per flow calculations, Sch 40, ASTM - A-106 Gr. B with seamless 3000 psi Socket weld fittings, Discharge nozzles, rigid angle supports,2 coats of zinc primer & 3 coats of P.O red paint. The equipments should be ISI Marked and Indian Seamless.
Supply, Installation, Testing & Commissioning of Two zone gas release panel with all requisite mounting accessories and it should be able integrate with other related and BMS System. The Panel should be Complete with Red Colour Housing, Power supply, required Battery charger & 30 min battery backup
Supply, Installation, Testing & Commissioning of Manual Abort Stations with DPDT Relay, The Abort will be monitored simultaneously by Fire Alarm System
Supply, installation, testing & commissioning of Manual Release Stations with DPDT Relay, The Release switch will be monitored simultaneously by Fire Alarm System.
Supply, installation, testing & commissioning of Sign Board with Marking "Gas Discharge. Do Not Enter". Should Operate on 24 V DC, Driven Through Gas Release Panel / CM (for use outside room)Supply, installation, testing & commissioning of Sign Board with Marking "Gas Discharge. Do Not Enter". Should Operate on 24 V DC, Driven Through Gas Release Panel / CM (for use outside room)
Supply, installation, testing & commissioning of Cylinder Discharge Pressure Switch, Shall be installed on the NOVEC 1230 piping.
LCD Projector.
SITC of LCD Projector with ceiling mounting stand ,Contrast Ratio:15,000:1,Light Output of 3,300 lumens,HDMI &USB Ports,EPSON-EB series or eqivalent as approved by client
SITC of HDMI Cable as approved by client for projectors
TRENCHING / FLOOR -RACEWAYS
Supply and laying Raceways / Conduits (for under floor trenches / On trays) on existing flooring. Raceways / conduits shall be fixed to the flooring with GI clamps for finished levels as per the site conditions or through partitions with all accessories. The rate shall include preparation of trenches of required sizes by carefully removing the malwa on existing floor for laying Raceways/conduits for power, data, telephone cables etc. The depth of the trenches shall be at least 2 inches from the finished floor level or upto RCC of the slab. The rate shall include the cost of the Raceways/conduits. The rate shall also include the activity of clearing the debris generated from the preparation of trenches
300 x 40 x 1.6mm thick GI Raceways
150 x 40 x 1.6mm thick GI Raceways
Supply & Installation of floor junction boxes without top cover for above raceways, of following sizes, fabricated out of M.S. sheets, fully powder coated with provision for removable M.S. / S.S. screwed cover plates on all four sides for blocking the entry into the junction box. All the junction boxes to be (with stud) 'properly earth - bonded with the raceways pipe using 12 SWG Copper bare wire as directed at site.
Junction Box of size (200mm x 200mm x 50mm x 2.5mm thick)
Junction Box of size (350mm x 350mm x 50mm x 2.5mm thick)
Supply & Installation of suitable sizes 2mm thick removable cover plate screwed on all four sides of M.S. sheet, fully powder coated, for blocking the entry into the floor junction box for following sizes of junction boxes with rounded corners as per the instruction given & sample approved by the client / architect / consultant at site. Cover plate shall have required no.s of 1' dia knockouts for flexible conduit outlets as per the requirement.
for Junction Box of size (200mm x 200mm x 50mm x 2.5mm thick)
Junction Box of size (350mm x 350mm x 50mm x 2.5mm thick)
Supplying & fixing of 2mm thick G.I. Perforated type cable Trays of Asian/Profab Engieers approved make. The cable tray shall be fixed to the ceiling / wall with MS angle support with 35mmx2mm thick GI slotted 'C' channel patti at an interval of 1 meter or the MS angle iron fabricated support depending upon the location. The rate shall include the cost of Supports, hardware & accessories, etc. complete as required.
Cable Tray :- 75 mm wide x 50 mm height x 2mm thick.
VOICE/TELEPHONE NETWORKING
Supply & Installation of Telephone /Voice point including approved make Cat - 6 UTP cable through already laid trenches / conduits, RJ45 information outlet, in single face plate, in workstation partion wall etc. with Termination, Testing and Documentation of UTP Points complete as required.
Supply, installation, testing and commissioning of indoor type telephone 200 pair Main Distribution Frame (MDF) / Box with Krone modules with suitable S.S. frame for mounting tag module, cable, wires and incorporated in 16 SWG MS box with proper lockable cover. The box should be fixed on wall with suitable fasteners including painting & earthing. This also includes fixing the cable, distribution chart sufficient space for the cables, wires etc.to be provided in the box.
Supply & Installation of and commissioning of indoor type telephone 50 pair MDF with Krone module including all hardware & accessoried , etc. complete as required.with suitable S.S. frame for mounting tag module, cable, wires and incorporated in 16 SWG MS box with proper lockable cover. The box should be fixed on wall with suitable fasteners including painting & earthing. This also includes fixing the cable, distribution chart sufficient space for the cables, wires etc.to be provided in the box
Supply & Laying of 20 pair telephone cable through heavy guage pvc conduit including all necessary hardware & accessories, etc.
HVAC Work
SITC of Chilled Water piping Insulation with 16 mm thick nitrile rubber insulation covered with 28 Swg aluminium sheet from existing Main Header to existing AHU
SITC of Temperature/Pressure Guage
SITC of Temperature Guage
SITC of Pressure Guage
Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.
Actuator (Make -Belimo)
Repairing ,Testing & commissioning of Existing AHU with exisitng installed valves Station, controller & VFD (The working of AHU on VFD is in vendor scope)
Thickness 0.63 mm sheet (24 Guage )
Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications.(Note-The VCD is to be installed/fixed inside existing ducting.All necessary cutting,duct joint gasket,nutbolt etc shall be in vendor scope)
Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core.
Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core.
Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required.
Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.
Supply, Installation and Testing of Bird Screens with GI wire mesh to be installed at the suction of fresh air/discharge of Exhaust air .
SITC of Hard PVC drain piping for AHU's with Plumbing Grade PVC pipe, with PE insulation & finished with PVC tape
Supply and fixing of acoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg/m³, with 25 mm X 25 mm GI section of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminum sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as required and as per specifications.(Glass covered with factory laminated Aluminium foil, stuck to the duct with Bitumen & finished with 2 "wide PVC Tape and bounded to the duct using Nylon binding strap at every 1 mtr.)
Acoustic insulation of duct with 12 MM thick CR-300 rigid board (Fiber Glass) covered with RP Tissue & 30 G perforated Aluminium cladding.
HI WALL SPLIT AC / Split AC Units - Supply, Installation, Testing & commissioning of split type airconditioning units, each comprising of an outdoor and single indoor unit, Condensing unit shall be complete with hermetically sealed semi-hermeticall/rotary compressor, air cooled condensor with fan. Evaporating unit shall consist of a fan section with amically balanced cenrifugal fans driven by FHP.or multirowsdeep copper cooling coil with aluminium fans,thermostatic expansion valves etc.osures shaall be fabricated as specified.The evaporating unit shall be piped with synthetic fibre filters,insulated drain pan,safety controls,thermostat all complete insist. The enclosure shall be factory painted to a smooth finish.The quoted price shall be inclusive of full of refregerants gas, vibration isolation pads etc.Refregerent shall be R-32/R410A/R407C.A. Single phase Non-ductable split units with Rotery compressor :Rating - 3 Star, single unit with single high wall non-ductable indoor unit with rotary compressor with corded remote controller & associated cable.
a)Capacity 2 TR
Split AC UNITS
Refrigeration Piping - Supply, installation, Testing & Commissionin of copper piping complete with copper fittings & charge of refregerant gas for the above units, Piping associated with split units to be insulated with 13 mm thick closed cell neric insulation in tubing form as required. Piping shall be laid over duly panted sotted angles trays fixed with GI pipes. Quoted price shall be inclusive of UV protection pant for all exposed pipes of approved make. Pair of Soft refregerant piping for split packages with rotary compressor. Price shal l be comprise of copper power cabling from indoor to outdoor unit as required.
DRAIN PUMP - Supply,Installation, Testing & Commissioning of On Line Type Condensate drain pump for Hi-wall units complete with water lavel sensor and accessories as required. Quoted price shall be inclusive of controller, NRVs & water sensors and associated wiring etc. to make installation complete.Drain pump shall be suitable for operation on 220+6%volts50 Hz 1phase AC power supply.Drain pumps shall automatically On/Off based on water lavel. Drain pump for Hi- wall split units
Condensate Drain Piping - Supply, Installation Testing and Commissioning of Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain fittings, including fixing the pipes with pipes clamps at 1.00 m spacings. Thi includes joints of pipes & fittings with one step CPVC solvent cement and testig of joints complete as per direction of Engineer in Charge. Supporting arrangement in accordance with the approved shop drawings and spacification. Pipes shall be insulated with 9mm thick closed cell elastometic insulation in tubing form. Pipes shall be of following Sizes:
40 MM Dia
25 MM Dia
ACOUSTIC LINING OF AHU ROOMS- Supplying, fixing acoustic lining on wall and ceiling of AHU rooms with 50mm thick, density 32 kg/cu.m resin bonded glass fiber insulation friction fixed in 610mm x 610 mm frame work made of 25X50X50X50X25 mm made out of 0.6mm thick GI sheet U shaped channel and covered with reinforced fiber glass tissue and finished with 0.80 mm perforated aluminium sheet etc. complete as required and as per specifications.( Quoted price shall be inclusive of GSS channel, metal screws, washers ,fibre glass tissue,perforated sheet etc. as required for complete installation.) Approved make- UP Twiga /Owens Corning. 50MM Thick
Installation of Motorised Fire Dampers with Linkage & dead weights / spring etc (Fire damper will be provided by C-DAC .All related work i.e fixing, wiring etc is in vendor scope)
CASSETTE AC WORK FOR CLASSROOM
FOR CLASS ROOM -Supply of Cassette AC of 3TR (2star non inverter model) with One year Comprehensive warranty.
FOR CLASS ROOM -Supply of Cassette AC of 1.5TR (2star non inverter model) with One year Comprehensive warranty.
Low Side
Indoor and outdoor unit Installation,testing, commissioning charges
REFREGERENT PIPING,POWER/CONTROL CABLING FOR CASSETTE AC:-Supply,Installation, Testing & Commissionin of copper piping complete with copper fittings & charge of refregerant gas for the above units(including drilling through wall), Piping associated with Cassette AC units shall be insulated with 13 mm thick closed cell elastomeric insulation .Quoted price shall be inclusive of UV protection paint for all exposed pipes.Price shall be comprise of copper power cabling from indoor to outdoor unit as required.
CONDENSATE DRAIN PIPING-Supply, Installation Testing and Commissioning of 25 mm dia. Chlorinated Polyvinyl Chloride (CPVC) pipes, including all CPVC plain fittings, including fixing the pipes with pipes clamps at 1.00 m spacings. This includes joints of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Supporting arrangement in accordance with the approved shop drawings and spacification. Pipes shall be insulated with 9mm thick closed cell elastometic insulation in tubing form.
MS FRAME FOR ODU OF SPLIT & CASSETTE AC'S-Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. (MS base frame duly applied with red-oxide primer & followed by black enamel paint for mounting of outdoor units.) In gratings, frames, guard bar, ladder, railings, brackets,gates and similar works
Dismantling of existing ducting and handing over /stacking the material at the location ( inside building premises) as directed by Engineer incharge
Installlation ,testing, commissioning of existing dismantled duct as directed by Engineer incharge
The above quoted prices are including freight, insurance, loading, un-loading, handling and allied charges to be incurred till installation at site.
Rama Infraprojects Pvt Ltd
Intermarc
BBP Electricals
maxcool solutions pvt ltd
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .