Loading…
Loading…
Tender Value
₹1.6 Cr
EMD Value
₹3.2 L
Closing Date
10 Jun 2026, 3:00 pmClosed
Executive Engineer, BUILDING DIVISION GAYA
EE
EE, Building Division Gaya, BCD, Gaya
Superintending Engineer, BUILDING CIRCLE GAYA
SE
CONSTRUCTION OF BOUNDARY WALL WITH GUARD ROOM FOR 80 P.O QUARTER AT DISTRICT GAYA JI
131715
NIT 41/BCD/GAYA/2025-26 GR 2
Open Tender
CIVIL
Gaya
• 1) Audited Annual Financial Turnover from Chartered Accountant for the years
• 2) Certificates by Employer (not below the rank of Executive Engineer) for successful completion of works during last five years, specifying
i. Name of work
ii. Employer
iii. Location
iv. Contract amount
v. Date of start
vi. Date of completion
vii. Number of storey
viii. Total built up area of building in contract
• 3) List of Works in hand (Existing Commitment) specifying
i. Name of work
ii. Employer
iii. Location
iv. Contract amount
v. Date of start
vi. Date of completion.
• 4) C.V. of Engineers with
i. Educational qualification certificate
ii. Individual affidavit of Engineer to perform the job if allotted to bidder
• 5) Document showing ownership of plants and equipment needed for successful completion of work :-
i. Automatic Batching plant with accessories
ii. Concrete Mixer with weighing facility
iii. Steel centering and shuttering showing area in square feet
iv. water Tanker
v. Vibrator
• 6) Details of financial availability:-
i. Certificate of any Nationalized Bank extending credit facility up to 10 % of B.O.Q Amount
ii. Self declaration of investing 25 % of B.O.Q Amount.
• 7) Certificates in the form of Affidavit by the bidder for: -
i. Bidder had not abandoned any project which was taken up by bidder
ii. Bidder had never been in Litigation lying in any court of law with employer of previous works
iii. Bidder had no relative or any person directly or indirectly involved in design, execution, supervision and testing of this tendered
• 8) Bidding Capacity statement
Bidding Capacity, BC = A x N x 2 ? B
Where,
A= Maximum ATO at current price level (with 8% annual indexation)
N = Time of completion of this tendered work in years
B = Value of works in hand (Existing Commitment of Bidder)
CIVIL
PERCENTAGE
L1
1
11 documents required · 11 mandatory
₹10,000
Processing Fee: 3540
₹3.2 L
AT OFFICE OF SE GAYA ON 25-05-2026 03:00 pm
17 May 2026
17 May 2026
11 Jun 2026
17 May 2026
10 Jun 2026
17 May 2026
25 May 2026
Earth work in excavation in foundation trenches or drains(not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
Foundations, footings, bases of columns, etc., for mass concrete.
Suspended floors, roofs, landings, balconies and access platform
Shelves (Cost in situ)
Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Columns, Pillars, Piers, Abutments, Post and struts
Edges of slabs and breaks in floors and walls :
Wheather shade, Chajja, corbels etc., including edges.
TMT-500- 8mm dia .
TMT-500-10 mm dia.
TMT-500-12 mm dia.
TMT -500-16 mm dia.
TMT -500-20 mm dia.
All work upto plinth level
All work above Plinth level upto floor V Level.
cement mortar 1:4 (1 cement : 4 coarse sand)
cement mortar 1:6 (1 cement : 6 coarse sand)
Metre
With chlorpyriphos/Lindone E.C. 20% with 1% concentration
Along the external wall below concrete or masonry apron using chemical emulsion @ 2.55 litres per linear metre including drilling and plugging holes etc.
Metre
Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling and plugging 12 mm diameter holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floor
Metre
Per 1000 Nos.
Metre
Metre
75 mm diameter
110 mm diameter
Coupler
Single tee with door
metre
metre
metre
metre
metre
15mm nominal outer dia pipes
20mm nominal outer dia pipes
15 mm dia
20 mm dia
Metre
Metre
With F.P.S. bricks (For Storm water)
With F.P.S. bricks (For Sewer)
F.P.S. bricks (For Storm water)
F.P.S. bricks (For Sewer)
Providing and making of following sizes octagonal street light pole foundation in reinforced cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size ) of specified size including PVC conduit, form work, curing, reinforcement, excavation and refilling etc. as required.
Supply and erection of 4 metre height Hot-dip galvanized octagonal street light pole with following arm with top dia 70 mm and bottom dia A/F 130 mm, made of 3 mm thick sheet along with base plate of size 220 X 220 X 12 mm , small door opening for junction box mounting including 6A 'C' series SP MCB, connector, and suitable size foundation bolts with template as required.(but without pole foundation)
Supplying and fixing following types LED street light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, IP 66 protection and complete with electronic driver etc on pole/building including connection earthing the body etc as required.
supplying and connection of following sizess ISI marked FRLS PVC insulated, single core copper conductor cable etc as regd.
Meter
Supply and fixing fabricated Feeder pillar of cubical construction, floor mounted type, fabricated out of 14 SWG CRCA sheet, compartmentalised with hinged doors, dust and vermin proof, powder coated painting of approved shade after 7 tank treatment process, cable alley, internal wiring, earth terminals, Bus bar Chamber, insulator, with 40mm X 40mm X 5mm angle iron stand and complete in all respect etc and must be CPRI approved panel manufactures. (But without RYB LED lamp, ammeter, voltmeter, inter-connection copper conductor cable/solid copper strip, switchgears, PCC work etc.)
32 mm X 6 mm copper strip
Supply and fixing panel mounted digital multimeter (Voltmeter & ammeter) including CT coil and RYB pilot indictor in the existing cubical panel board including drilling holes in the panel board making connections etc as required.
Supplying and fixing following rating, 240/415 volts, ‘C’ curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit as required.
Meter
Meter
supply of follwing size and core XLPE/ PVC insulated PVC heathed ( Heavy duty) armoured electric cable with aluminium conductor etc. as required.
Metre
Meter
Meter
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required but excluding sand cushioning and protective covering.
Meter
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. ( but without charcoal/ coke and salt ) as required.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble as required.
Supplying and fixing post top / garden light (width 200 mm) made up of high grade unbreakable polycarbonate material suitable for upto 7 watt LED lamp including connections and earthing the body etc as required. ( But without lamp)
Supplying and fixing of following types lamp in the existing electrical fitting/ fixtures etc. as required.
Wiring for light point/ fan point/ exhaust fan point/ Call bell Point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit with modular switch, modular Plate, suitable size G.I box etc. as required.
Point
Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
Supplying and fixing suitable size of G.I. box with modular plate and cover in front or in surface or in recess including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Wiring for light/ power plug with 2 X 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 1 Nos 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
Meter
Meter
Supplying and fixing following way single pole & neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar,neutral bus bar,earth bar, din bar inerconnections, powder painted including earthing etc. as reqd.(But without MCB/RCCB/Isolator)
Supplying and fixing following rating, 240/415 volts, ‘C’ curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 2 pin, 5/6 amp. ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and fixing batten/ angle holder including connection etc. as required.
Supplying and fixing of following types lamp in the existing electrical fitting/ fixtures etc. as required.
Supplying and fixing 4' X 18 watt LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor etc. as required.
Supplying and fixing following types LED street light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, IP 66 protection and complete with electronic driver etc on pole/building including connection earthing the body etc as required.
Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required.
Supply, Instaiiation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling Fan with BLDC motor, class of insulation: B, 3 nos blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value (CM/MM) minimum 6.00, Air delivery minimum 210 cum/min, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise = 75 degree C(max), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, earthing etc. complete as required. Make :- Bajaj/Crompton/Orient/Usha.
Supplying and fixing two module stepped type electronic Fan regulator on the existing modular plate/ switch box including connections but excluding modular plate etc. as required.
Providing and fixing following capacity double pole / TP&N sheet metal switch disconnector fuse unit in the existing metal panel board with rewireable type fuses including drilling holes in metal panel, making connections etc. as required.
supply of follwing size and core XLPE/ PVC insulated PVC heathed ( Heavy duty) armoured electric cable with aluminium conductor etc. as required.
Metre
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
MARKING CHART_1094.pdf
NIT • 3.92 MB
UDIN LETTER FOR ATO.pdf
NIT • 2.18 MB
NIT 41.pdf
NIT • 2.91 MB
Boundary Wall_New1 (2) - civil + elec.xls
NIT • 0.62 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .