Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹56.0 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹64.5 L+₹7.2 L (12.7%)Rejected-AOC | L2 | Rejected-AOC NOT THE LOWEST BIDDER |
Tender Value
Refer Docs
EMD Value
₹1.0 L
Closing Date
21 May 2021, 12:00 pmClosed
CWE NAGPUR
Commander Works Engineers Bldg No P-9, Sitabuldi Fort,Nagpur 440 001 Pin-900419, C
SPECIAL REPAIRS TO BLDG NO T-17 (MT GARAGE) AT GRC KAMPTEE
2021_MES_427677_2
84694/E8
Open Tender
Civil Works
Item Rate
180 days
GE KAMPTEE
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
GE KAMPTEE
₹1.0 L
Yes
3 Jun 2021
29 Apr 2021
22 May 2021
29 Apr 2021
21 May 2021
8 May 2021
29 Apr 2021 - 3 May 2021
Amount
Dismantling of asbestos cement/transculent sheet corrugated/ semi-corrugated sheets in roof coverings including ridges, complete all as specified and directed.
Supply and fixing Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws, complete all as specified and directed.
Supply and fixing Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws, complete all as specified and directed.
Dismantling of wall and ceiling board (fibre,insulation etc) or insulation board , slabs, blankets, any thickness including cover fillets, complete all as specified and directed.
Material and labour for providing and fixing snap grid for false ceiling of size 595x595mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel section @ 90grams/sqm, both side inclusive) consisting main ''T'' runner with suitably spaced joints to get required length and of size 24mmx38mm made from 0.25mm thick (minimum) sheet, spaced at 1200mm centre to centre and cross ''T'' of size 24mmx25mmx1200mm made of 0.25mm thick (minimum) sheet,1200mm long spaced between main spaced between main ''T'' at 600mm centre to centre to from a grid of 1200x600mm and secondry cross ''T'' of length 600mm and size 24mmx25mmx600mm made of 0.25mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 24x24x0.4mm including, required cutting/making, opening for services like diffusers,grills light fittings, fixtures , smoke detectors etc, Maint ''T'' runners to be suspended from ceiling using slotted cleats of size 27x37x25x1.0mm fixed to ceiling.4mm GI adjustable rods with galvansied butterfly level clips of size 85x30x0.5mm spaced at 1200mm centre to centre along main T , bottom exposed width of 24mm of all T-sections shall be pre-painted with polyester paint, complete all as specified and directed.
Material and labour for 4mm thick non asbestos fibre cement building designer boards of size 595x595mm fixed or laid/ inserted to timber/GI/Aluminium frame work fixed in ceiling flat or sloping, complete all as specified and directed.
Material & labour plain cement concrete Type 1:3:6 type C-1 (using 20 mm graded stone aggregate) as in coping, haunching rounded or chamfered on edges including necessary from work, complete all as specified and directed.
Supply and fixing structural rolled mild steel as in roof trusses (framed), purlins crane gantries, rail and fastenings and heavy brackets framing (beam, tee, angle, channel or flat section) including distance pieces, cleats etc., complete all as specified and directed.
Supply and fixing miled steel screws bolt (machine) with Hexagonal or square heads at home at one end and screwed the other, each screwed end to be fitted with washers and one hexagonal or square nuts exc 5cm long and 10 to 15mm dia, complete all as specified and directed.
Dismantling of brick work or stone/boulder masonary built in cement mortar including ashalar facing dressed stoen and pre-cast concrete articles, complete all as specified and directed.
Material and labour for brick work with fly ash bricks straight or curved on plan exc 6 mtr mean radius built in CM 1:6(Using old size brick), complete all as specified and directed.
Material & labour for Rendering 15 mm thick CM 1:6 on brick or concrete surfaces finished even & smooth without using extra cement, complete all as specified and directed.
Material & labour for Rendering 15 mm thick CM 1:4 on brick or concrete surfaces finished even & smooth without using extra cement , complete all as specified and directed.
Material and labour for preparation of new steel surafces of any description over 10 cm width or girth & applying two coats of synthetic enamel paint over a coat of redoxide primer, complete all as specified and directed.
Material and labour for PCC 1:3:6 Type B-I (using 20mm graded stone aggregate) in surface channels and drains, complete all as specified and directed.
Material and labour extra forming fair finishes drain or channel 30cm inner grith in cement concrete using extra cement including forms, moulds,mitred/stopped ends etc, complete all as specified and directed.
Dismantling of floor hearth or wall tiling including cement mortar bedding , but not backing, complete all as specified and directed.
Material and labour machine cut kota stone slab flooring 18-22mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing over screed bed or bedding layer of mortar 20mm thick cement mortar 1:3, complete all as specified and directed.
Material and labour Kota stone slab 15-20mm thick in riser of steps, skirting, dado ansd pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing over 10mm thick rendering in cement mortar 1:3 on fair faces of brick work or concrete surface as backing, complete all as specified and directed.
Demolition of plain cement concrete in ground floor & paving not exc 15 cm thick above or below g round level, complete all as specified and directed.
Material and labour for 100mm thick PCC 1:4:8 Type D2 (using 40mm graded stone aggregate) in sub base, complete all as specified and directed.
Material and labour for RCC M-25 (design mix) in ground floor (for grade slab) or raft slab (using 20mm graded stone aggregate) , complete all as specified and directed.
Material and labour for RCC M-25 (design mix) in footing & plint beams (using 20mm graded stone agggregate) , complete all as specified and directed.
Material and labour for RCC M-25 (design mix) in roof beams & lintel beam )using 20mm graded stone aggregate), complete all as specified and directed.
Material and labour for RCC M-25 (design mix) in column (using 20mm graded stone aggregate), complete all as specified and directed.
Material and labour for TMT Mild steel bars 8mm dia ,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mmdia or securing with clips, complete all as specified and directed.
Material and labour for TMT Mild steel bars 10mm dia and over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mmdia or securing with clips, complete all as specified and directed.
Material and labour for formwork to sides and sofits of plinth beam . Sides of footings, base of column and similar work with rough finished surface etc., complete all as specified and directed.
Material and labour for formwork to sides of column and similar work with fair finished surface etc., complete all as specified and directed.
Material and labour for formwork to sides of beam lintel and similar work with fair finished surface etc., complete all as specified and directed.
Material and labour for formwork to edges of concrete falts l and similar work exc 10cm and not exc 20cm wide with fair finished surface etc., complete all as specified and directed.
Material and labour forming 12mm thick expansion joints filed with preformed bituminous filler and top 30mm primed and sealed with sealing compound (Grade A) for 150mm thick slab, complete all as specified and directed.
Material and labour for Forming Contraction (Dummy) joints 65mm deep x 10mm wide,filled with sealing compoun with (Grade A), complete all as specified and directed.
Demolition of reinforced concrete in ground floor & paving not exc 15 cm thick above or below g round level, complete all as specified and directed.
Material & labour PCC (1:3:6) Type C1 (using 20 mm graded stone aggregate), 50 mm thick as in plinth protection and finishing surfaces even & smooth without using extra cement, complete all as specified and directed.
Forming Construction joint 30mm deep x 10mm wide filled with sealing compound with Grade A, complete all as specified and directed.
Taking down Chowkats or frames incl. shutters (without taking of shutter from the frames) n. exc 1.50 Sqm each, complete all as specified and directed.
Taking down Chowkats or frames incl. shutters (without taking of shutter from the frames) exc 1.50 Sqm and not exc 4 sqm, complete all as specified and directed.
Supply and fixing 35mm thick second class hardwood plain framed factory made panelled shutters with lock rail & panel of 9mm BWP commercial ply as per IS 1003 (Pt-I), kiln seasoned & chemically pressure treated, complete all as specified and directed.
Material and labour for second class hardwood (SAL) plain,solid straigt chowkats and frame wrought framed rebated on the soid rounded chemfered put together with glue pinned at joint, complete all as specified and directed.
Supply and fixing 100 mm long Mild steel medium weight cold rolled butt hinges and fixed with screw/welded to frames etc., complete all as specified and directed.
Supply and fixing 125 mm Extruded Aluminium handles fabricated type anodised etc., complete all as specified and directed.
Supply and fixing 300 mm long mild steel sliding door bolts stove enamelled black, with bright bolt not less than 12 mm dia with and including minimum of six bolts and nuts, four on bolt plate and two on staple plate etc., complete all as specified and directed.
Supply and fixing 150 mm long aluminium anodised, barrel tower bolt of extruded section, complete all as specified and directed.
Material and labour for Preparation of new wooden surfaces of any description over 10 cm width or girth & applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed.
Supply and fixing steel ventilator factory made with top hung shutter including hinges steel peg stay glazing bars, complete all as specified and directed.
Supply and fixing framed guard bars with mild steel Square bars with ends of bars shouldered and/ or riveted and similar work confirming to FE 410-O or FE 310-0, complete all as specified and directed.
Supply and fixing sheet glass figured glass pin head , 3 mm thick and glazing with oil putty in square n. exc. 0.50 Sqm in each pane, complete all as specified and directed.
Material and labour for preparation of wall newly plastered surfaces & appling three coats of white wash, complete all as specified and directed.
Material and labour for preparation of old steel surafces of any description over 10 cm width or girth & applying one coats of synthetic enamel paint, complete all as specified and directed.
Material & labour for preparation of newly plastered surfaces of wall & applying two coats of cement base paint, complete all as specified and directed.
Taking down point wiring with aluminum conductor cable of light point fan & socket light & power complete including light fittings any type switches, sockets, ceiling rose, switch boards, bell/buzzer, bell push, tube light fitting, regulator etc, and making good to the disturbed surfaces of walls/ floor etc to match with existing surfaces including white washing/colour washing/ distemper to match with existing wall/floor/ceiling finishes, complete all as specified and directed.
Taking down sheet metal enclosure DB, MCB, main switch etc and making good disturbed surfaces to match with existing surfaces, complete all as specified and directed.
Taking down sub main wiring of any size/ capacity complete all as specified and making good disturbed surfaces to match with the existing surfaces, complete all as specified and directed.
Material and labour point wiring 1100 volt grade single core FRLSH PVC insulated and unsheathed cable with multistranded copper conductor 1.50 sqmm drawn in and including electrical grade PVC conduit not less than 20mm dia with IS 9537 (Part-III) 1983 marked medium grade concealed on surface of wall/ceiling including FRLSH PVC insulated unsheathed earth wire with multistranded copper conductor of size 1.50 sqmm pressed steel modular boxes sunk on wall for mounting of modular switches, switch sockets, fan regulator etc including modular cover with frame any size complete all as specified and making good disturbed surfaces for one light point controlled by one, one way switch, complete all as specified and directed. Cable Make : Finolex, L&T, Legrand, Havells, Polycab PVC Conduit Make : Polycab, Anchor, Finolex Note :- Cost of cable provided from sub main DB to respective switch board in rooms shall be included in the quoted point wiring rate. All switches, fan, sockets, ceiling roses and holders shall be connected to common earth dolly.
Ditto all as per item No 55 above but One ceiling /exhaust fan point controlled by one switch and regulator, complete all as specified and directed.
Ditto all as per item No 55 above but One 3 pin 5 amp socket out point on the same board with other switches, complete all as specified and directed.
Ditto all as per item No 55 above but One 3 pin 5 amps socket out let point on independent board, complete all as specified and directed.
Ditto all as per item No 55 here in before but wiring with 4.0 sqmm multi stranded cable and earth wire with copper conductor of size 4.0 sqmm for 15 amps power point, complete all as specified and directed.
Material and labour for sub main wiring with two single core PVC FR LSH insulated unsheathed stranded copper conductor and earth wire 1100 volt grade and drawing into PVC conduit not less than 20 mm medium grade concealed in wall of the following sizes :- 2x 4.0 Sqmm with earth wire of 1x4.0 Sqmm. Cable Make : Finolex, L&T, Legrand, Havells, Polycab PVC Conduit Make : Polycab, Anchor, Finolex Note :- Accessories for point/sub main wiring like PVC junction box, bend, Tee, elbow shall be of same make.
Ditto all as per item No. 60 above but size 2x 6.0 Sqmm with earth wire of 1x6.0 Sqmm, complete all as specified and directed.
Supply and fix ceiling rose surface type 2/3 terminal 5 amps, complete all as specified and directed. Make : Anchor / Roma, Legrand, Crabtree
Supply and fix Modular switch one way 6A, 1 module, complete all as specified and directed. Make : Anchor / Roma, Legrand, Crabtree
Supply and fix Modular switch one way 16A, 1 module, complete all as specified and directed. Make : Anchor / Roma, Legrand, Crabtree
Supply and fix Modular Socket 6A 2/3 pin combined 2 module , complete all as specified and directed. Make : Anchor/ Roma, Legrand, Crabtree
Supply & Fix Modular Socket 6A/ 16A 2/3 pin combined 2 module , complete all as specified and directed. Make : Anchor/ Roma, Legrand, Crabtree
Supply and fix Modular Fan step regulator,120 watt 2 module , complete all as specified and directed. Make : Anchor/ Roma, Legrand, Crabtree
Supply and Fix Highly durable surface mounted 18/20 watts LED batten/surface constructed of fire retardant engineering grade extruded aluminium body and decorative end cap complete with driver having lumen output 2000, 230V, 50Hz with heat sink housing , 100 Lumen/W, 6500K, 2KV surge protection including 3 core 1.0 sqmm copper conductor cable for connection and accessories, complete all as specified and directed. Make :-CG LDL-20-CDL/ Wipro LL20-281-XXX-65-AL1/Philips/ Luker/ Bajaj.
Supply & fix light fitting 9W LED bulk head luminaries with lamp holders etc complete with all accessories and including connecting up with twin core twisted flexible cable suitable size of 230V, 50HZ , complete all as specified and directed. Make: CG LBHP-10-CDL/Philips/ Luker.
Supply and fix building security light LED 25 W with Lumen O/P 1800 with driver with rated voltage 240 V, 50Hz,including mounting GI (made out of 25 mm dia light grade pipe 0.8 m bent two shape including FI clamps nut bolts etc., complete all as specified and directed. Make : CG LSTS-25-CDL/ Philips/ Luker.
Supply and fix sheet metal enclosure vertical triple pole & neutral(VTPN) with MCCB 40 amps for 415 volts 4 way with 200 Amp rated bus bar flush /surface mounting double door, complete all as specified and directed. Make-Legrand/ Siemens/ Schneider
Supply and fix sheet metal enclosure single pole & neutral for 240 volts 8 way with 200 Amp rated bus bar flush /surface mounting double door, complete all as specified and directed. Make-Legrand/ Siemens/ Schneider
Supply and fix MCB single pole 240 volt 6 to 40 amps 10 KA breaking capacity, 'C' series, complete all as specified and directed. Make-Legrand/ Siemens/ Schneider
Supply and fix MCB single pole and neutral 240 volt 6 to40 amps 10 KA breaking capacity, 'C' series, complete all as specified and directed. Make-Legrand/ Siemens/ Schneider
Earthing complete with galvanized street earth plate electrode 600x600x6mm thick buried directly in ground (earth plate not less than 2.25mtr deep below normal ground level) with top edge of the plate not less then 1.50 mtr. below the normal ground level connected to galvanized earth lead wire 4.00 mm dia by means of bolts nuts check nuts & washer of galvanized iron or steel all as shown in electrical plate No 3 connected to earthing test point all as specified and testing on completion including the material and labour for :- (a) Excavation and earth work or drilling hole for electrode in any type of soil (b) PCC pit in cement concrete 1:2:4 TYPE B-1 (c) Pre cast RCC cover with suitable handle 40mm thick in PCC 1:2:4 reinforced with welded steel wire fabric weighting not less than 1.87 Kg/sqmm (d) Funnel with watering pipe of GI 20mm nominal bore medium grade and Aluminum lugs etc all as specified. (e) 15mm nominal bore medium grade GI protection pipe up to 7.50 meter long for protection of earthing lead. (f) Requisite quantity of charcoal and common salt (g) Connection to earthing test point and testing on completion.
Excavation in trenches for laying of cables, poles and stay in any type of soil not exceeding 1.5 mtr wide and not exceeding 1.50 mtr deep and getting out, complete all as specified and directed.
Returning filling in,including spreading, leveling watering and well ramming in layers not exceeding 25 cms thick, complete all as specified and directed.
Removing excavated materials not exceeding 50 Mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point, complete all as specified and directed.
Supply and fix Double wall Corrugated High Density Polymer Ethyl (HDEP) pipe for laying of Electric cable of size 50 mm outer diameter and 38 mm inner Diameter with IS 14930 (part 2) 2001 and 6 mm thickness laid in trenches,wall, floor , pole including bends, sockets and other connected accessories, complete all as specified and directed. Make: Ketron/ Tirupati.
Supply and laying in trenches or fixing in walls / poles or drawing through pipe XLPE insulated, screened,PVC bedded, galvanised steel strip or wire armoured,electric power cables ( heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 25 sq mm, 3.5 core including testing after laid and jointed, complete all as specified and directed. make: Polycab/ Havells/ Finolex.
Supply and laying in trenches or fixing in walls / poles or drawing through pipe XLPE insulated, screened,PVC bedded, galvanised steel strip or wire armoured,electric power cables ( heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 50 sq mm, 3.5 core including testing after laid and jointed, complete all as specified and directed. make: Polycab/ Havells/ Finolex.
Dismantling existing old unserviceable LT panel board by properly disconnecting all existing electrical connection & including breaking of existing foundation & making good all disturbed area, complete all as specified and directed.
NOTE :- SCHEDULE OF CREDIT (Amount shall be deducted offline from the total quoted amount to workout the net contract sum to be considered for acceptance.) [(-) Rs.1,31,853.00/- ]
chronicle enterprises
Bidder Name
Meet Road Lines
chronicle enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .