Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.1 LAccepted-AOC DAYA BAGH SATTANI DHAR ROAD UDHAMPUR DISTT UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | ₹25.1 L Quoted ₹26.3 L | L1 | Accepted-AOC BEING L1 |
| 2 | L2₹27.1 L+₹79,920.01 (3.04%)Rejected-Finance WARD NO 16 HOUSE NO 66 SALLIAN TALAB UDHAMPUR 182 101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | ₹27.1 L+₹79,920.01 (3.04%) | L2 | Rejected-Finance BEING L2 |
| 3 | L3₹32.2 L+₹5.9 L (22.6%)Rejected-Finance | ₹32.2 L+₹5.9 L (22.6%) | L3 | Rejected-Finance BEING L3 |
| 4 | L4₹33.2 L+₹6.9 L (26.4%)Rejected-Finance | ₹33.2 L+₹6.9 L (26.4%) | L4 | Rejected-Finance BEING L4 |
| 5 | L5₹33.6 L+₹7.3 L (28.0%)Rejected-Finance B 56 LANE NO 4A SECTOR 7 VASHNAVI ENCLAVE CHANNI HIMAT JAMMU 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | ₹33.6 L+₹7.3 L (28.0%) | L5 | Rejected-Finance BEING L5 |
| Sl No | Description | Qty | Unit | slathia construction works L7 | PAWAN KUMAR GOVT. CONTRACTORS L3 | DAVINDER SINGH L9 | LUXMI ELECTRONIC WORKS L2 | M/SHansrajbuilder L1 | PROACH ASSOCIATES BUILDERS & ENGINEERS L8 | ASIA BUILDER L6 | ANIKET TRADERS L5 | KARAN TRADERS L4 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M & L for repair/replacement to APFC panel of any make and capacity located at various location of 39 Wing AF Station Udhampur including taking down to control wiring/relay/contactor/CT/PT/capacitor bank, cleaning with air blower & replacement to non functional part etc and reassembling, testing, commissioning, Re-programming of relay & increasing or decreasing of steps all including of fixing additional of contactor, fuse unit, MCCB & Control / power wiring etc shall be included in quoted rates.
Note :- (i) Spare items shall be measured and paid separately.
(ii) The rates quoted by the contactor shall include cost of any other spare parts not mentioned herein but essentially required for functioning of the system.(iv) Unit rates quoted by tenderers shall deem to include for Nuts&bolts, washers, lugs, thimble, wires etc alongwith welding job if required and petty items required for efficient and smooth functioning of the equipment without any extra cost to the Govt. | 15 | Each Job | 5,000 ₹75,000 | 200 ₹3,000 Lowest | 5,000 ₹75,000 | 600 ₹9,000 | 400 ₹6,000 | 5,500 ₹82,500 | 1,000 ₹15,000 | 500 ₹7,500 | 2,000 ₹30,000 |
| 2.00Supply only cylindrical heavy duty capicitor 440/415 (V) (AC) 3 phase, 50 Hz for APFC panel complete all as specified and directed by engineer in charge KVAR rating Make : Havells/ HPL/ L&T/ HAVELLS/C&S/ABB/EPCOS | ||||||||||||
| 2.01 | 1 KVAR | 5 | Each | 400 ₹2,000 | 250 ₹1,250 | 5,000 ₹25,000 | 120 ₹600 Lowest | 365 ₹1,825 | 2,500 ₹12,500 | 1,000 ₹5,000 | 220 ₹1,100 | 300 ₹1,500 |
| 2.02 | 2 KVAR | 10 | Each | 600 ₹6,000 | 450 ₹4,500 | 5,000 ₹50,000 | 240 ₹2,400 Lowest | 700 ₹7,000 | 3,000 ₹30,000 | 1,000 ₹10,000 | 444 ₹4,440 | 350 ₹3,500 |
| 2.03 | 5 KVAR | 10 | Each | 850 ₹8,500 | 875 ₹8,750 | 7,000 ₹70,000 | 500 ₹5,000 | 1,700 ₹17,000 | 3,500 ₹35,000 | 2,000 ₹20,000 | 1,200 ₹12,000 | 450 ₹4,500 Lowest |
| 2.04 | 10 KVAR | 10 | Each | 3,000 ₹30,000 | 1,800 ₹18,000 | 10,000 ₹1,00,000 | 1,100 ₹11,000 | 1,850 ₹18,500 | 4,500 ₹45,000 | 2,000 ₹20,000 | 1,600 ₹16,000 | 450 ₹4,500 Lowest |
| 2.05 | 20 KVAR | 10 | Each | 3,500 ₹35,000 | 3,500 ₹35,000 | 12,000 ₹1,20,000 | 1,800 ₹18,000 | 3,600 ₹36,000 | 6,500 ₹65,000 | 5,000 ₹50,000 | 2,000 ₹20,000 | 450 ₹4,500 Lowest |
| 3.00 | M&L for in replacement of pilot lights direct integral LED of 230 volts ,colour red complete all as specified and directed by Engr-in-Charge. | 20 | Each | 50 ₹1,000 | 250 ₹5,000 | 50 ₹1,000 | 30 ₹600 Lowest | 120 ₹2,400 | 2,500 ₹50,000 | 400 ₹8,000 | 200 ₹4,000 | 100 ₹2,000 |
| 4.00 | M&L for in replacement of pilot lights direct integral LED of 230 volts ,colour green complete all as specified and directed by Engr-in-Charge. | 20 | Each | 50 ₹1,000 | 250 ₹5,000 | 50 ₹1,000 | 20 ₹400 Lowest | 120 ₹2,400 | 3,000 ₹60,000 | 400 ₹8,000 | 300 ₹6,000 | 100 ₹2,000 |
| 5.00 | M&L for in replacement of non illuminated pushbutton turn to release of dia of head 40 mm ,type of contact NC colour red complete all as specified and directed by Engr-in-Charge. | 15 | Each | 100 ₹1,500 | 200 ₹3,000 | 50 ₹750 | 20 ₹300 Lowest | 85 ₹1,275 | 400 ₹6,000 | 150 ₹2,250 | 300 ₹4,500 | 150 ₹2,250 |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
8 Sept 2025, 6:00 pmClosed
GE AF UDHAMPUR
GE AF STATION UDHAMPUR
REPAIR / MAINT OF UNSERVICEABLE APFC PANEL, MCCBs 415V SARVO STABLIZER AND OTHER CONNECTED WORK AT AF STN UDHAMPUR
2025_MES_725456_1
GEAFU-44/2025-26
Open Tender
Civil Works
Item Rate
180 days
GE AF STATION UDHAMPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF UDHAMPUR
₹90,000
4 Oct 2025
11 Aug 2025
10 Sept 2025
11 Aug 2025
8 Sept 2025
25 Aug 2025
11 Aug 2025 - 18 Aug 2025
Amount
M & L for repair/replacement to APFC panel of any make and capacity located at various location of 39 Wing AF Station Udhampur including taking down to control wiring/relay/contactor/CT/PT/capacitor bank, cleaning with air blower & replacement to non functional part etc and reassembling, testing, commissioning, Re-programming of relay & increasing or decreasing of steps all including of fixing additional of contactor, fuse unit, MCCB & Control / power wiring etc shall be included in quoted rates. Note :- (i) Spare items shall be measured and paid separately. (ii) The rates quoted by the contactor shall include cost of any other spare parts not mentioned herein but essentially required for functioning of the system.(iv) Unit rates quoted by tenderers shall deem to include for Nuts&bolts, washers, lugs, thimble, wires etc alongwith welding job if required and petty items required for efficient and smooth functioning of the equipment without any extra cost to the Govt.
Supply only cylindrical heavy duty capicitor 440/415 (V) (AC) 3 phase, 50 Hz for APFC panel complete all as specified and directed by engineer in charge KVAR rating Make : Havells/ HPL/ L&T/ HAVELLS/C&S/ABB/EPCOS
M&L for in replacement of pilot lights direct integral LED of 230 volts ,colour red complete all as specified and directed by Engr-in-Charge.
M&L for in replacement of pilot lights direct integral LED of 230 volts ,colour green complete all as specified and directed by Engr-in-Charge.
M&L for in replacement of non illuminated pushbutton turn to release of dia of head 40 mm ,type of contact NC colour red complete all as specified and directed by Engr-in-Charge.
M&L for standard extended rotary handle for 100/160/250 amper complete all as specified and directed by Engr-in-Charge.
M&L for in replacement of three phase voltmeter CI0.5 as per IEC 61010-1,50 Hz AC,LED indicators complete . Make: : Schneider -electric,cat part No. METSEDDM3210 or equivalent approved model in Legrand/ ABB/ C&S complete all as specified and directed by Engr-in-Charge.
M&L for in replacement of three phase Ammeter CI0.5 as per IEC 61010-1,50 Hz AC,LED indicators complete . Make: : Schneider -electric,cat part No. METSEDDM3110 or equivalent approved model in Legrand/ ABB/ C&S complete all as specified and directed by Engr-in-Charge.
M&L for in replacement of MPP heavy duty can type, power capacitors 3 phase 12.5 kVAr,440 volts ,50 Hz complete all as specified and directed by Engr-in-Charge. Make : Schneider -electric, /ABB/ Legrand/ C&
M&L for in replacement of MPP heavy duty can type , power capacitors 3 phase 5 kVAr,440 volts ,50 Hz complete all as specified and directed by Engineer-in Charge make : Schneider -electric,cat part no.MEHVCHDY050A44 or equivalent approved model in Legrand/ ABB/ C&S complete all as specified and directed.
M&L for in replacement of MPP heavy duty can type , power capacitors 3 phase 20 kVAr,440 volts ,50 Hz complete all as specified and directed by Engineer-in Charge make : Schneider -electric,cat part no.MEHVCHDY050A44 or equivalent approved model in Legrand/ ABB/ C&S complete all as specified and directed.
M&L for in replacement of capacitor duty contactor (AC coil) ,nominal reactive power 440 volts, 3 phase , 50 Hz of capacity 5 KVAR with auxilliary contacts (1 NO+2NC) complete all as specified and directed by Engr-in-Charge Make : Schneider -electric,cat part No. LC1DFK* or its equivalent Legrand/ ABB/ C&S.
M&L for in replacement of capacitor duty contactor (AC coil) ,nominal reactive power 440 volts, 3 phase , 50 Hz of capacity 12.5 KVAR with auxilliary contacts (2 NO+2NC) complete all as specified and directed by Engr-in-Charge Make : Schneider -electric,cat part No. LC1DFK* or its equivalent Legrand/ ABB/ C&S.
M&L for in replacement of capacitor duty contactor (AC coil) ,nominal reactive power 440 volts, 3 phase , 50 Hz of capacity 25 KVAR with auxilliary contacts (2 NO+2NC) complete all as specified and directed by Engr-in-Charge. Make : Schneider -electric,cat part No. LC1DMK11*C or its equivalent Legrand/ ABB/ C&S
M&L for in replacement of capacitor duty contactor (AC coil) ,nominal reactive power 440 volts, 3 phase , 50 Hz of capacity 40 KVAR with auxilliary contacts (2 NO+2NC) including taking down old complete all as specified and directed by Engr-in-Charge Make : Schneider -electric,cat part No. LC1DTK*C or its equivalent Legrand/ ABB/ C&S.
S&F,testing and commissioning of Automatic power factor correction (APFC) panel 3 Phase of capacity 100 KVA including proper connections of control wiring/relay/contactor/CT/PT unit /capacitor bank and fixing additional of contactor, fuse unit, MCCB & Control / power wiring etc complete with 4 No’s mounting legs made out of 50 mm x 50 mm x 6 mm angle iron grouted in PCC block of size 30 cm x 30 cm x 90 cm (30 cm depth below ground level and 60 cm above ground level) in cement concrete 1:3:6, type C-2 (using 40 mm grade crushed stone aggregate), and connections with size of aluminium thimbles, nuts, bolts & washers including cable glands at entry and outlet points including excavation and earth work, returning filling and removal of surplus soils including taking down old all as specified and directed by Engr-in-charge. Note:-(i) Drawing of APFC panel shall be got approved from GE. (ii) Panel shall be installed at least 60 cm above ground level. (iii) All T&P required for fixing of panel shall deemed to be included in the quoted rate.
S&F,testing and commissioning of Automatic power factor correction (APFC) panel 3 Phase of capacity 60 KVA including proper connections of control wiring/relay/contactor/CT/PT unit /capacitor bank and fixing additional of contactor, fuse unit, MCCB & Control / power wiring etc complete with 4 No’s mounting legs made out of 50 mm x 50 mm x 6 mm angle iron grouted in PCC block of size 30 cm x 30 cm x 90 cm (30 cm depth below ground level and 60 cm above ground level) in cement concrete 1:3:6, type C-2 (using 40 mm grade crushed stone aggregate), and connections with size of aluminium thimbles, nuts, bolts & washers including cable glands at entry and outlet points including excavation and earth work, returning filling and removal of surplus soils including taking down old all as specified and directed by Engr-in-charge. Note:-(i) Drawing of APFC panel shall be got approved from GE. (ii) Panel shall be installed at least 60 cm above ground level. (iii) All T&P required for fixing of panel shall deemed to be included in the quoted rate.
S&F,testing and commissioning of Automatic power factor correction (APFC) panel 3 Phase of capacity 150 KVA including proper connections of control wiring/relay/contactor/CT/PT unit /capacitor bank and fixing additional of contactor, fuse unit, MCCB & Control / power wiring etc complete with 4 No’s mounting legs made out of 50 mm x 50 mm x 6 mm angle iron grouted in PCC block of size 30 cm x 30 cm x 90 cm (30 cm depth below ground level and 60 cm above ground level) in cement concrete 1:3:6, type C-2 (using 40 mm grade crushed stone aggregate), and connections with size of aluminium thimbles, nuts, bolts & washers including cable glands at entry and outlet points including excavation and earth work, returning filling and removal of surplus soils including taking down old all as specified and directed by Engr-in-charge. Note:-(i) Drawing of APFC panel shall be got approved from GE. (ii) Panel shall be installed at least 60 cm above ground level. (iii) All T&P required for fixing of panel shall deemed to be included in the quoted rate.
S&F,testing and commissioning of Automatic power factor correction (APFC) panel 3 Phase of capacity 200 KVA including proper connections of control wiring/relay/contactor/CT/PT unit /capacitor bank and fixing additional of contactor, fuse unit, MCCB & Control / power wiring etc complete with 4 No’s mounting legs made out of 50 mm x 50 mm x 6 mm angle iron grouted in PCC block of size 30 cm x 30 cm x 90 cm (30 cm depth below ground level and 60 cm above ground level) in cement concrete 1:3:6, type C-2 (using 40 mm grade crushed stone aggregate), and connections with size of aluminium thimbles, nuts, bolts & washers including cable glands at entry and outlet points including excavation and earth work, returning filling and removal of surplus soils including taking down old all as specified and directed by Engr-in-charge. Note:-(i) Drawing of APFC panel shall be got approved from GE. (ii) Panel shall be installed at least 60 cm above ground level. (iii) All T&P required for fixing of panel shall deemed to be included in the quoted rate.
Taking down after shutdown and disconnecting existing primary/secondary side of repairable Servo voltage transformer of capacity upto 400 KVA indoor /outdoor type and removing/ taking down for repair from existing cable and including earth strip all as specified and directed by Engr-in-Charge. NOTE :-(i)The contractor shall return the Stabilizer duly repaired with in 20 days other wise a penalty of Rs 1000/- per day will be recovered from the firm. (ii) All type of T &P i.e Hydra etc for lifting of Servo stabilizer from working site and safely equipment shall be provided by the contractor.
Transportation to UNSV servo voltage stabilizer of any capacity/size/make from various location of 39 wing A/F station Udhampur and Dismantling the UNSV parts such as core winding with core,Servo Motor, R.C. circuit, dimmerstate, buck and booster transformers, carbon bush etc. and reassembly the same after repair/replacement to defective parts. (i) Transportation,deassembly/assembly/testing/commission/painting with writing of MES/SM No of appropriate size of letter etc and re-fixing to it in original location shall be done in quoted rate.Nothing shall be extra payment to contractor. (ii) The new spair parts/copper winding etc. shall be measure and paid separately..
Voltage stabilizer oil low viscosity type conforming to IS 330 for topping up of stabilizer, complete all as specified and directed by Engr-in-Charge.
Material and Labour for Dehydration/centrifuging of servo voltage stabilizer of capacity upto 400 KVA to make the oil fit for reuse or oil as per standard procedure upto strength level 60 KV all including Oil topping up (new oil for toping/or for replacement shall be measured and paid separately) etc complete all as specified and directed by Engineer-in-Charge.
Supply only in replacement micro switches, complete all as specified and directed by Engr-in-Charge. Make :- Kaycee/ESSAN/Volina/as per existing parts
Supply only in replacement Auto manual switches, complete all as specified and directed by Engr-in-Charge. Make :- Kaycee/ESSAN/Volina/as per existing parts
Supply only in replacement high and low voltage indicators, complete all as specified and directed by Engr-in-Charge. Make :- VAISHNO/HARRY/Volina/as per existing parts
Supply only in replacement panel indicator lamp for main ‘ON’ indication, complete all as specified and directed by Engr-in-Charge. Make :- VAISHNO/HARRY/Volina/as per existing parts
Supply only in replacement push button switch, complete all as specified and directed by Engr-in-Charge. Make :- Kaycee/ESSAN/Volina/Volina/as per existing parts
Supply only in replacement Volt meter, complete all as specified and directed by Engr-in-Charge. Make:- ABB/HPL/L&T/Havells/Meco/AE/Premier/Volina/as per existing parts
Supply only in replacement Electronic sensing card (PCB), complete all as specified and directed by Engr-in-Charge. Make :- AE/VINTEC/VOLINA/BLUEHILL/Volina/as per existing parts
Supply only in replacement microprocessor based control card for each phase, complete all as specified and directed by Engr-in-Charge. Make :- AE/VINTEC/VOLINA/BLUEHILL/Volina/as per existing parts
Supply only in replacement rotary switch for voltmeter RY-YB-BR-OFF-RN-YN-BN, complete all as specified and directed by Engr-in-Charge. Make :- KAYCEE/RICO/Volina/as per existing parts
Supply only in replacement rotary switch for ammeter RY-YB-BR, complete all as specified and directed by Engr-in-Charge. Make :- KAYCEE/RICO/Volina/as per existing parts
Supply only in replacement servo motor 3 Kg torque, complete all as specified and directed by Engr-in-Charge. Make :- AE/Volina/UNISTER/Volina/as per existing parts
Supply only in replacement servo motor 10 Kg torque, complete all as specified and directed by Engr-in-Charge. Make :- AE/Volina/UNISTER/Volina/as per existing parts
M&L for rewinding of servo motor capacity 3 Kg/10 Kg Torque with insulating/ varnishing, testing/commissioning etc with transportation/desmentling etc complete all as specified and directed by Engr-in-Charge.
S&F in repair RC network for servo motor 3Kg/10 Kg, complete all as specified and directed by Engr-in-Charge. Make :- AE/Volina/UNISTER/Volina/as per existing parts
S&F in repair carbon bush, complete all as specified and directed by Engr-in-Charge. Make :- AE/Volina/UNISTER/Volina/as per existing parts
S&F in repair dimmerstate unit of capacity suitable for 40 KVA to 100 KVA, complete all as specified and directed by Engr-in-Charge. Make :- AE/Volina/Green Dot/as per existing parts
S&F in repair dimmerstate unit of capacity suitable for 160 KVA to 200 KVA, complete all as specified and directed by Engr-in-Charge. Make :- AE/Volina/Green Dot/as per existing parts
S&F in repair dimmerstate unit of capacity suitable for 250 KVA to 300 KVA, complete all as specified and directed by Engr-in-Charge. Make :- AE/Volina/Green Dot/as per existing parts
S&F in repair Buck and booster transformer(Main Transformer) 40 to 100 KVA, complete all as specified and directed by Engr-in-Charge. Make :- AE/Volina/Vintek Electronics./as per existing parts
S&F in repair Buck and booster transformer(Main Transformer) 160 to 200 KVA, complete all as specified and directed by Engr-in-Charge. Make :- AE/Volina/Vintek Electronics./as per existing parts
S&F in repair Buck and booster transformer(Main Transformer) 250 to 300 KVA, complete all as specified and directed by Engr-in-Charge. Make :- AE/Volina/Vintek Electronics./as per existing parts
M&L for painting of the servo stabilizer complete by removing old paint by scraping and providing spary painting with approved synthetic enamelled paint of capacity 10 KVA to 400 KVA with marking the MES No and date of painting, complete all as directed by Engineer-in-charge
40 KVA to 100 KVA
160 to 200 KVA
250 to 300 KVA
M&L for painting LT panel of any type or size with two coats of synthetic enamelled grey paint over a coat of red oxide primer with brush of suitable size also write down the serial No and date of painting including preparation of old painted surface after taking shut down of that panel complete all as specified and as directed.
M&L in repair for MS angle of size 40x40x4 mm powder coated for holding cable trays with complete nuts and bolts and washers to match with the colour with cable tray complete all as specifed and directed.
M&L for tracing the LT UG cable fault with either LT cable fault locator or manually digging by labour in any situation/position etc, complete all as specified and directed. NOTE:-Contractor has to rectify the fault within 08 hrs after info by concerned AGE/JE otherwise a penality of Rs 500/- per hrs would be imposed. (ii) One Single cable of any length for end to end termination with any number/type of faults will be considered to consitute only one qty for tracing and payment purpose.
M&L Earthing complete as per electrical plate No 3 of MES SSR Part I with galvanised steel plate earth electrode 60 cm x 60 cm x 6.0mm, burried directly vertically in ground in a pit of depth not less than 2.5 metres below ground level with the top edge of earth plate at a depth not less than 1.5 m below normal ground level, connected to galvanisediron or steel strip 25x4 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel. Earthing wire protected by galvanised iron or steel pipe 50 mm bore medium grade and connected to continuous earth wire on pole/ test point. Watering pipe shall be 20mm bore GI medium grade. The earthing shall be inclusive of excavation and earth work in any type of soil,charcoal, salt,funnel , PCC pit and RCC cover complete all as specified & directed by Engr-in-Charge. Note 1- following items deemed to be included in quoted rate (a) Earth electrode. (b) Main earthing lead from earth electrode to test point and further to equipment to be earthed upto 7.5 metre. (c) Material and labour for connecting earth electrode and earthing lead as specified. (d) Adequate quantity of charcoal dust and common salt as per direction. (e) All labour involved including testing of earth net work. (f) Excavation and earth work or drilling hole for electrode. (g) P.C.C. pit and C.I. cover. (h) Funnel with watering pipe, wire mesh and copper lugs etc. as specified. (j) G.I. protection pipe of size ordered specified for protection of earthing lead from mechanical injury or tempering. Note 2 - On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.
M&L Earthing complete as per electrical plate No 5 of MES SSR Part I with copper earth plate earth electrode 60 cm x 60 cm x 3.15 mm, burried directly vertically in ground in a pit of depth not less than 2.5 metres below ground level with the top edge of earth plate at a depth not less than 1.8 m below normal ground level connected to and including cupper earthing strip 20 x 3 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel. Earthing wire protected by galvanised iron or steel pipe 50mm bore medium grade and connected to continuous earth wire on pole/ test point. Watering pipe shall be 20 mm bore GI medium grade. The earthing shall be inclusive of excavation and earth work in any type of soil,charcoal, salt,funnel , PCC pit and RCC cover complete all as specified & directed. Note 1- following items deemed to be included in quoted rate (a) Earth electrode. (b) Main earthing lead from earth electrode to test point and further to equipment to be earthed upto 7.5 metre. (c) Material and labour for connecting earth electrode and earthing lead as specified. (d) Adequate quantity of charcoal dust and common salt as per direction. (e) All labour involved including testing of earth net work. (f) Excavation and earth work or drilling hole for electrode. (g) P.C.C. pit and C.I. cover. (h) Funnel with watering pipe, wire mesh and copper lugs etc. as specified. (j) G.I. protection pipe of size ordered specified for protection of earthing lead from mechanical injury or tempering. Note 2 - On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.
Test point terminal block made of gun metal or phosphorous bronze size 75 x 75 x 25mm drilled and screwed including 3 Nos. 8 mm dia 25 mm long hexagonal head screws complete all as specified and directed including taking down old unserviceable.
Supply and lay DWC HDPE pipe 50 mm bore medium class, ISI Marked double wall corrugated for open/underground laying cable, cut to size and making the tubing for cable protection including cutting of road etc/cutting of PCC and making the good surface complete all as specified and directed by Engr-in-Charge. Note (a) The using of GI Clamp in the wall/drainage rate are deemed to be included in the quoted rate. (b) The insulation of DWC pipe should be of high that does not deteriorate with UV rays/ heavy sun rays/winter season etc. (c) Drawing existing cable through DWC pipe shall be deemed to be included in the quoted rates. as in cable protection pipe of outer dia 40mm including all fittings complete all as specified and directed.
Supply and lay DWC HDPE pipe 80 mm bore medium class, ISI Marked double wall corrugated for open/underground laying cable, cut to size and making the tubing for cable protection including cutting of road etc/cutting of PCC and making the good surface complete all as specified and directed by Engr-in-Charge. Note (a) The using of GI Clamp in the wall/drainage rate are deemed to be included in the quoted rate. (b) The insulation of DWC pipe should be of high that does not deteriorate with UV rays/ heavy sun rays/winter season etc. (c) Drawing existing cable through DWC pipe shall be deemed to be included in the quoted rates. as in cable protection pipe of outer dia 40mm including all fittings complete all as specified and directed.
M&L for Aluminium Lugs of size 25 sqmm complete all as per specified and directed.
M&L for Aluminium Lugs of size 35 sqmm complete all as per specified and directed.
M&L for Aluminium Lugs of size 50 sqmm complete all as per specified and directed.
M&L for Aluminium Lugs of size 70 sqmm complete all as per specified and directed.
M&L for Aluminium Lugs of size 95 sqmm complete all as per specified and directed.
M&L for Aluminium Lugs of size 120 sqmm complete all as per specified and directed.
M&L for Aluminium Lugs of size 150 sqmm complete all as per specified and directed.
M&L for Aluminium Lugs of size 185 sqmm complete all as per specified and directed.
M&L for repair to existing LT panels broken front and rear doors of by using suitable hinges & door lock with necessary welding work all as specified and as directed by Engineer-in-charge.
M & L for PCC 1:3:6 type C2 with using 40 mm graded aggregate as in foundation of broken transformer plinth , panel, pole, bus bar etc with necessary form work complete as specified and directed by Engr-in-Charge.
M&L for type PCC 1:2:4 type B-1 using 20 mm graded stone aggregate in coping etc for broken transformer plinth , panel, pole, bus bar etc including necessary form work complete all as specified and directed by Engr-in-Charge.
S & F street light bracket made out of 40/50 mm dia GI heavy grade tubing not less than 1.5 Mtr long bend to shape including pole clamps made out of 50 x 6 FI and nut bolts and washers complete all as specified and directed by Engr-in-Charge.
Supply and Laying Cable XLPE insulated screened PVC bedded galvanized steel strips or wire armoured, cables (heavy duty) ISI marked with stranded aluminium conductor, 1100 volts grade and connecting and testing in trenches, under floors/ roads or on walls complete including taking down old complete all as specified and directed of following sizes :- (Note 1.: Earth work, excavation shall be measured & paid separately under respective item of Schedule and wherever cable laying on walls and uses of thimbles etc rates shall deemed to be included in the quoted rates). Make- Havells/Gloster/Polycab
95 Sqmm, 3.5 Core
120 Sqmm, 3.5 Core
10 Sqmm, 4 core cable
16 Sqmm, 4 core cable
35 Sqmm, 3½ core cable
150 Sqmm, 3½ core cable
185 Sqmm, 3½ core cable
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for laying of cable and foundation of poles, stays and getting out in any type of soil, all as specified.
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each layer in any type of soil complete all as specified and as directed by Engineer-in-Charge.
Removing surplus excavated material to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete, all as specified and as directed by Engineer-in-Charge.
M & L for Sand cushioning to underground cable, provided with a layer 8 cm before and 15 cm after laying and stretching jointing and testing the cable all as specified and directed. by Engineer-in-Charge. Note: Punned thickness of sand shall be measured.
Common burnt sub class ‘B’ brick laid flat in trenches over and across the length of cable with length of brick perpendicular to the direction of cable adjacent/abutting each other complete all as specified and directed for cable protection.
Repair and replacement of GI tube light grade of bore 80 mm with all fittings and fixed complete to walls and ceiling or laid in floor for cable crossing including cutting of bitumen roads/PCC and making good after laying of cable up to building height complete including taking down all as specified and directed by Engr in charge
Repair and replacement of GI tube light grade of bore 150 mm with all fittings and fixed complete to walls and ceiling or laid in floor for cable crossing including cutting of bitumen roads/PCC and making good after laying of cable up to building height complete including taking down all as specified and directed by Engr in charge
M & L for cutting of Road and Concrete surfaces upto 300 mm depth and 500 mm wide for laying of cable / pipe in any type of soil, returning and filling in and spreading, leveling, watering and well ramming in layers not exceeding 25cm thick removal of surplus soil and provision of 150 mm thick PCC type B-1, 1:2:4 with 20mm graded crushed stone aggregate on top layer all as specified and as directed.
M&L for in replacement of Varlogic APFC relays- classic range RT6,6 step ,440 volts,5 Amps Make : Schneider -electric,cat part No. 51207 or equivalent approved model in Legrand/ C&S complete all as specified and directed by Engr-in-Charge.
M&L for in replacement of Varlogic APFC relays- classic range RT8, 8 step ,440 volts,5 Amps Make : Schneider -electric,cat part No. 51209 or equivalent approved model in Legrand/ C&S complete all as specified and directed by Engr-in-Charge.
S & F in repair Procom DGC-6D controller for electronic control panel of existing make/type/rating/model for AMF panel boards etc and taking down old unserviceable complete all as directed by Engr-in-Charge.
S & F in repair ET-8000 controller for electronic control panel of existing make/type/rating/model for AMF panel boards etcand taking down old unserviceable complete all as specified and directed.
Laying under ground cables/Re-routing only LT UG cable of size 10 sqmm x 2,10 sqmm x 4 core to 185 sqmm x 3.5 core cable shall be provided under Sch 'B' or the existing overground and laying cable along with connection with LT panel/Pole or Other electrical equipment with proper thimble/Aluminium lugs and making good all as specified and as directed by Engr-in-Charge. Note :- (i) Execavation / Returning / Filling / cable protection and sand cushioning shall be measured and paid separately. (ii) Quoted rate shall be inclusive of cutting cable/jointing of cable, provision of thimbles, lugs, cable gland for connection of cable IN / OUT from Panels/Feeder Piller Boxes/Bus bar as per Site requirement. (iii) The crimping shall be done only by Hand Operated / Hydraulically Operated Crimping Tool after applying conducting jelly and no other method will be allowed. (iv) Extra use of cable shall be measured & paid separately in case of non availability of EM store.
M & L Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles with the help of insulator or any other indicated situation for loop earthing etc and provision of brass/copper nuts, bolts washers etc wherever required and making joints as required 32 x 6 mm galvanised iron strip complete all as specified and directed by Enginer-in-Charge.
Supply and fixing in repair of Weather proof outdoor bus bar chamber of rating IP-65 made out of 3.15 mm thick CRCA sheet of comprising 4 Nos Aluminium strips each of 400 Amps, powder coated 60 cm long duly insulated mounted on insulators complete with 4 No’s mounting legs made out of 50 mm x 50 mm x 6 mm angle iron grouted in PCC block of size 30 cm x 30 cm x 90 cm (30 cm depth below ground level and 60 cm above ground level) in cement concrete 1:3:6, type C-2 (using 40 mm grade crushed stone aggregate), and connections with size of aluminium thimbles, nuts, bolts & washers including cable glands at entry and outlet points including excavation and earth work, returning filling and removal of surplus soils, including taking out old unserviceable bus bar chamber complete all as specified and directed by Engr-in-charge .as per site requirement with the following :-
(a) Bus bar electrolytic grade Aluminium and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulator 400 Amp,4 pole, not less then 60 CM long mounted on insulators for incoming supply - 1 Set Set of 4 strips) (b) Phase indicator lamp RYB LED type - 1 Set (c) C.T's of suitable ratio (Set of three) (d) Red,Yellow,Green Phase indicating Lights LED type 220V AC- 1 Set. (Set of three). Make of Metering Accessories :-L&T/ AE/ Trinity/ Schneider. (e) Incoming:- MCCB 315 amps , 36 KA 4 pole, Ics= 100% of Icu, adjustable type Qty- 01 no Make of MCCB:-L&T/ Siemens / Legrand (f) Outgoing:-(i) MCCB 250 Amps ,25 KA 4 pole, Ics= 100% of Icu, adjustable type Qty- 01 no Make of MCCB:-L&T/ Siemens / Legrand (ii) MCCB 160 amps , 16 KA 4 pole, Ics= 100% of Icu, adjustable type Qty- 02 nos Make of MCCB:-L&T/ Siemens / Legrand (iii) MCCB 100 amps , 16 KA 4 pole, Ics= 100% of Icu, adjustable type Qty- 02 nos Make of MCCB:-L&T/ Siemens / Legrand The panel manufacturer should have following Govt. Approved Certificates: 1. Panel shall be installed at least 60 cm above ground 2. All civil/electrical work & material is deemed to be included in the quoted rates 3. Drawing of Lt panel shall be got approved from GE.
Supply & installation and testing & Commissining CPRI approved outdoor cubical type IP 65,LT feeder piller box suiable for 415 V, 3 phase 50 Hz , AC supply system, dust,weather & vermin proof, made of 3.15 mm thick CRCA sheet, powder coated ,TPN Aluminium busbars of rating 250 Amp Cap.Bottom base channel of MS section not less then 45mmx45mmx5mm thick, entire panel shall have a common aluminium earth bar of size 25mm x5mm at the rear with 2 no earth stud,double door both side opening single door system lockable/openable by key from both sides having flush pattern fancy locks with louvers. cable entry with glands, foundation/grouting on & including PCC as per site requirement with the following :- (a) Bus bar electrolytic grade Aluminium and supported on corrosive SMC insulator 250 Amp,4 pole, not less then 45 CM long mounted on insulators for incoming supply - 1 Set (Set of 4 strips) (b) Phase indicator lamp RYB LED type - 1 Set (Set of three). (c) Digital Voltmeter & Ammeter - 02 Nos (d) CT of suitable ratio (Set of three) Incoming: (a) MCCB 160 Amp, 415V, 50 Hz, FP, ,25 ka, Ics= 100% Icu fixed type, complete all as specified and directed by Engr-in-Charge. Note :- 1. Panel shall be installed at least 60 cm above ground 2. All civil/electrical work & material is deemed to be included in the quoted rates 3. Drawing of Lt feeder panel shall be got approved from GE.
M&L for Weather proof outdoor bus bar chamber wall mounted, made out of MS sheet comprising of Aluminium strips each of 200 Amps, 4 way,appx 60cm long duly insulated mounted on insulators including complete with all accessories and connections with copper thimbles, nuts, bolts & washers including cable glands at entry and outlet points including taking out old unserviceable bus bar chamber complete all as specified and directed by Engr-in-charge. Make :-Havells cat part No IHBC020004 or its equivalent as approved by GE.
M&L for Weather proof outdoor bus bar chamber wall mounted, made out of MS sheet comprising of Aluminium strips each of 200 Amps, 8 way,appx 60cm long duly insulated mounted on insulators including complete with all accessories and connections with copper thimbles, nuts, bolts & washers including cable glands at entry and outlet points including taking out old unserviceable bus bar chamber complete all as specified and directed by Engr-in-charge. Make :-Havells cat part No IHBC020008 or its equivalent as approved by GE.
Supply, installation, testing and commissioning of cubical compartmentized outdoor type IP-65 LT panel vermin proof, weather proof, front and rear door openable with locking arrangement fabricated out of 3.15 mm thick CRCA sheet steel and base channel and suitable for operation on 415 volts, 50 Hz Ac supply with switchgear and accessories as given below complete with pad locking sealing arrangement earthing stud lebeling, painting, inter/connections providing of danger plates etc as per specifications and comprising with following:- INCOMING a)MCCB 250 amps , 25 KA 4 pole, Ics= 100% of Icu, adjustable type with overload setting 0.8 ln to 1.0 In,Qty- 01 no Make of MCCB:-L&T/ Siemens / Legrand /schneider b) Digital Multifunction meter -01 set make:L&T/AE. d) LED type indication lights for ON, OFF, TRIP and three phase -01 set make AE/L&T. e) Bus bar suitable for 300 Amps, mounted on insulators- 04 No's made of Aluminum dulydrilled hole for cable connections.
OUTGOING: a)MCCB 200 amps , 25 KA 4 pole, Ics= 100% of Icu, adjustable type with overload setting 0.8 ln to 1.0 In,Qty- 01 no Make of MCCB:-L&T/ Siemens / Legrand /schneider (b) MCCB 160 amps , 25 KA 4 pole, Ics= 100% of Icu, adjustable type with overload setting 0.8 ln to 1.0 In,Qty- 01 no Make of MCCB:-L&T/ Siemens / Legrand /schneider (c) MCCB 100 amps , 25 KA 4 pole, Ics= 100% of Icu, adjustable type with overload setting 0.8 ln to 1.0 In,Qty- 01 no Make of MCCB:-L&T/ Siemens / Legrand /schneider (d) TPN 63 Amps,10 KA Qty- 02 no Make of TPN:-L&T/ Siemens / Legrand /schneider (e) All accessories prewired with suitable size copper conductor cable/strip including thimble/cable lugs with foundation of panel as required or recommended by manufacturer: make of panel: Electric field/DVEPL/ Tricolite. Note :- 1. Panel shall be installed at least 60 cm above ground 2. All civil/electrical work & material is deemed to be included in the quoted rates 3. Drawing of Lt panel shall be got approved from GE. 4. panel shall confirm to IEC - 61439 updated to date. 5. All MCCB's shall be confirm to ICS=100% of ICU.
Material and labour for MCCB 4 Pole, 415 V, fixed type,thermal magnatic load ICS100% of ICU, 63 Amps with breaking capacity 16 KA complete all as specified and directed. Make :- Standard/Havells/Schneider/ABB or equivalent as approved by GE.
Material and labour for MCCB 4 Pole, 415 V, fixed type,thermal magnatic load ICS100% of ICU, 100 Amps with breaking capacity 16 KA complete all as specified and directed. Standard/Havells/Legrand or equivalent as approved by GE.
Material and labour for MCCB 4 Pole, 415 V, adjustable type, adjustable type,thermal magnatic load ICS100% of ICU, 0.8 ln to 1ln, 160 Amps with breaking capacity 25 KA complete all as specified and directed. Standard/Havells/Legrand or equivalent as approved by GE.
Material and labour for MCCB 4 Pole, 415 V, adjustable type,thermal magnatic load ICS100% of ICU, 0.8 ln to 1ln, 250 Amps with breaking capacity 36 KA complete all as specified and directed. Make :- Standard/Havells/Schneider/ABB or equivalent as approved by GE.
Material and labour for MCCB 4 Pole, 415 V, adjustable type, adjustable type,thermal magnatic load ICS100% of ICU, 0.8 ln to 1ln, 400 Amps with breaking capacity 36 KA complete all as specified and directed. Standard/Havells/Schneider/ABB or equivalent as approved by GE.
Supply and fix heat shrinkable End termination kits and accessories of following capacities and type:-
Outdoor/indoor 70 to 150 Sqmm 3.5/4 core cable jointing kit for 1.1 KV grade cable
Outdoor/indoor 185 Sqmm 3.5/4 core cable jointing kit for 1.1 KV grade cable
Outdoor/indoor 35 to 50 Sqmm 3.5/4 core cable jointing kit for 1.1 KV grade cable
Supply and fix heat shrinkable straight through joint kit and accessories of following capacities and type:-
Straight through joint kit indoor/outdoor al conductor cable of size 70 to 150 Sqmm and 3.5/4 core
Straight through joint kit indoor/outdoor al conductor cable of size 185 Sqmm and 3.5/4 core
Supply only non -metallic PVC clamps required for cables laying above the wall/drainage/PCC area of size 20 sqmm etc.complete all as specified & as directed.
Supply only non -metallic PVC clamps required for cables laying above the wall/drainage/pcc area of size 40 sqmm etc.complete all as specified & as directed.
Disconnecting and taking out the unserviceable battery from battery bank any capacity supply and fix new lead acid maintenance free battery 2 volt 100 AH or as per existing make/model/capacity including connecting of all battery in battery bank and testing upto satisfaction of engineer - in-charge complete as specified and directed
Disconnecting and taking out the unserviceable battery from UPS of any capacity supply and fix new lead acid maintenance free battery 12 volt 26 AH or as per existing make/model/capacity including connecting of all battery in UPS and testing upto satisfaction of engineer - in-charge complete as specified and directed
Supply and fixing and passing through pipes/poles cable 1.5 Sqmm 2 core cable, PVC insulated and PVC round sheathed, copper conductor (flexible) industrial cable, 1100 volt, confirming to IS :694 including replacement of old unsv cable.
LUXMI ELECTRONIC WORKS (BID ID -3419453)
PAWAN KUMAR GOVT. CONTRACTORS (BID ID -3412903)
KARAN TRADERS (BID ID -3419265)
ANIKET TRADERS (BID ID -3412135)
ASIA BUILDER (BID ID -3411992)
slathia construction works (BID ID -3412889)
PROACH ASSOCIATES BUILDERS & ENGINEERS (BID ID -3412784)
DAVINDER SINGH (BID ID -3418811)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .