Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹5.8 LAccepted-AOC NEAR SVN UNIVERSITY NARSINGHPUR ROAD SIRONJA SAUGOR MP 470228 | SAUGOR | SAGAR | MP | 470228 | 1 | Accepted-AOC Valid Lowest Bidder | |
| 2 | 2₹6.6 L+₹71,940 (12.1%)Rejected-Finance 1442 1 NANADANPURA BABINA CANTT TEHSIL DISTT JHANSI UP | BABINA | JHANSI | UP | 2 | Rejected-Finance Not Lowest Bidder | |
| 3 | 3₹6.7 L+₹72,370 (12.2%)Rejected-Finance | 3 | Rejected-Finance Not Lowest Bidder | |
| 4 | 4₹6.7 L+₹77,580 (13.1%)Rejected-Finance SNEH NAGAR COLONY NEAR ABKARI OFFICE SHIVAJI WARD SAGAR MP 47000 | SAGAR | SAGAR | MP | 47000 | 4 | Rejected-Finance Not Lowest Bidder | |
| 5 | 5₹7.4 L+₹1.4 L (24.4%)Rejected-Finance 202 NEW RAM VIHAR COLONY PINTO PARK MORAR GWALIOR 474005 | GWALIOR | GWALIOR | MP | 474005 | 5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹8 L
EMD Value
₹16,000
Closing Date
25 Jul 2022, 6:00 pmClosed
Manash Kumar Das AE Civil
AGE I DHANA PIN 470228, DIST SAGAR, MP
REPAIR/REPLACEMENT OF DG SET, BATTERY BANK, FIRE ALARM SYSTEM AND ALLIED WORKS AT DHANA MIL STN.
2022_MES_530025_1
8300/DH/25/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE I Dhana
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Assistant Garrison Engineer (I) Dhana
₹16,000
Yes
25 Aug 2022
11 Jun 2022
27 Jul 2022
11 Jun 2022
25 Jul 2022
25 Jun 2022
Amount
M&L for Maintenance and servicing of DG set of capacity 140 to 160 KVA draining out of diesel from tank, cleaning the tank thoroughly and refilling drained diesel, drain out engine oil from the oil sump cleaning the sump and refilling the sump with new engine oil of Make K Oil 20W/40, to its maximum level, applying petroleum jelly on the Battery terminals and cleaning the entire DG set, checking and rectification of any defects of output voltage, RPM, exhaust leakages etc. Tightening the foundation & exhaust manifold bolts & nuts and testing as directed by the Engineer in Charge including replacement of following items complete all as directed and specified by Engr -In-Charge. (a) Fuel filter element (b) Oil filter elements (c) V-Belt (d) Air cleaner filter (e) Magnet Pickup (f) Hose pipe for radiator (g) Flexible Hose for vent (h) Fuel pipe return
M&L for Maintenance and servicing of DG set of capacity 12.5 KVA draining out of diesel from tank, cleaning the tank thoroughly and refilling drained diesel, drain out engine oil from the oil sump cleaning the sump and refilling the sump with new engine oil of Make K Oil 20W/40, to its maximum level, applying petroleum jelly on the Battery terminals and cleaning the entire DG set, checking and rectification of any defects of output voltage, RPM, exhaust leakages etc. Tightening the foundation & exhaust manifold bolts & nuts and testing as directed by the Engineer in Charge including replacement of following items complete all as directed and specified by Engr -In-Charge. (a) Fuel filter element (b) Oil filter elements (c) V-Belt (d) Air cleaner filter (e) Magnet Pickup (f) Hose pipe for radiator (g) Flexible Hose for vent (h) Fuel pipe return
M & L for preparation of old steel surface by cleaning, stopping and rubbing down and applying two coat of synthetic enamel spray painting on old painted steel surface of existing colour including cabin (inside & outside ) of any type of DG set all as directed and specified by Engr -In-charge.
S & F on pole / wall off load change over switch of capacity 100 Amps, 415 volts, side operated complete all as specified and directed.
M & L Engine oil 15W 40 of approved make as approved by EIC complete all as specified and directed.
M&L for dismantling existing unserviceable radiator and carrying out repair by draining out water/coolant, carrying out pressure test and rectifying leakage by brazing/soldering test and reinstalling including topup/filling fresh coolant as on required basis all as directed and specified for DG set upto 160 KVA capacity etc., complete all as specified and directed.
Dismantling of unserviceable self starter 12 volts of DG Set of capacity 160/140/12.5 KVA including replacement of worn out parts like bendex, piston, bush housing etc including refixing and testing etc., complete all as specified and directed by Engr -In-charge.
Dismantling of unserviceable dynamo/alternator of DG Set of capacity 160/140/12.5 KVA including replacement of worn out parts like carbon bushes, solenoid switch bearing, armature etc including refixing and testing etc., complete all as specified and directed. by Engr -In-charge.
S & F in repairs Battery (Maintenance free) 12 volt 180 AH For DG Set with connection complete all as specified and directed.
Supply only distilled water in sealed bottle of one liter capacity complete all as specified and directed.
Dismantling existing inside roof sheet with insulation of DG set capacity up to 140 KVA To 160KVA including repair of sheet with suitable insulation complete all as specified as directed.
M&L for Earthing with GI earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less than 1.5 M below normal ground level, connected to galvanized steel strip of size 32X6mm including 40 mm dia light grade protection, pipe 20mm dia watering pipe with funnel, CI hinged cover, PCC chamber and excavation and earth work complete all as described and shown in EP plate No 3 of SSR part I 2009 print and testing on completion all as specified and directed.
Supply and fix in repairs battery terminal made out of brass/bronze heavy duty suitable for 92 AH/180 AH 12 Volt Battery complete all as specified and directed.
Supply only Grease Multipurpose to increase equipment/ bearing life, Excellent resistance to throw off & water wash, Maximum protection offered against rust & corrosion complete all as specified and directed. Make:- Castrol, Servo, Mobil
Comprehensive maintenance and Repair/servicing of APFC Panel of following capacity for maintaining Power factor including by replacing the connected items etc installed for water supply installation complete all as specified and directed. Note :- Capacitor, Contactor, MCB will be measured and paid separately. (a) 90 KVAR APFC Panel at Bannad Pump House
(a) 60 KVAR APFC Panel at Filter Pump House
Taking down unserviceable capacitor and Supply and fix in replacement cylindrical capacitor metalized poly propylene heavy duty (MPP - H) for three phase 440 V and 50 Hz system for permissible non - linear load 15 % of 1 KVAR capacity complete all as specified and directed. Make:- Neptune, L&T, Epcos
All as per item No 17 above but for 2 KVAR capacity complete all as specified and directed. Make:- Neptune, L&T, Epcos
All as per item No 17 above but for 3 KVAR capacity complete all as specified and directed. Make:- Neptune, L&T, Epcos
All as per item No 17 above but for 6.5 KVAR capacity complete all as specified and directed. Make:- Neptune, L&T, Epcos
All as per item No 17 above but for 10 KVAR capacity complete all as specified and directed. Make:- Neptune, L&T, Epcos
All as per item No 17 above but for 12.5 KVAR capacity complete all as specified and directed. Make:- Neptune, L&T, Epcos
All as per item No 17 above but for 25 KVAR capacity complete all as specified and directed. Make:- Neptune, L&T, Epcos
S & F in repair 3 pole contactor for capacitor switching 30 KVAR capacity, 220-240 Volts, 60 Hz complete all as specified and directed. Make- Cat no. UA30-30-10RA of ABB or equivalent in L &T, Schneider
S & F in repair 3 pole contactor for capacitor switching 12.5 KVAR capacity, 220-240 Volts, 60 Hz complete all as specified and directed. Make- Cat no. UA16-30-10RA of ABB or equivalent in L &T, Schneider
S & F in repair 3 pole contactor for capacitor switching 7.5 KVAR capacity, 220-240 Volts, 60 Hz complete all as specified and directed. Make- Cat no. UA9-30-10RA of ABB or equivalent in L &T, Schneider
Painting to existing APFC /LT panel board only one coat of synthetic enamel paint over a coat of red oxide primer after scraping, cleaning of old surface of electric panel complete all as specified and directed.
Taking down unserviceable volt meter and supply and fix digital volt meter range up to 500 Volt complete all as specified and directed.
Taking down unserviceable Amp meter and supply and fix digital Amp meter range up to 300 Amp complete all as specified and directed.
Taking down unserviceable lamp indicator RYB and supply and fix led lamp indicator RYB complete all as specified and directed.
Comprehensive maintenance and Repair/servicing of two zone fire alarm panel by checking all connections and minor repairs complete all as specified and directed.
Comprehensive maintenance and Repair/servicing of six zone fire alarm panel by checking all connections and minor repairs complete all as specified and directed.
M&L for repair/servicing of two zone fire alarm control panel, 230V, AC, 50Hz including replacement of following connected unserviceable items complete all as specified and directed by Engr-in-charge. (a) Battery with Charger (b) Fault LED indicator (c) Reset/silence switch (d) Relay
S & F smoke detector complete all as specified and directed.
S & F in replacement MCCB 4 pole 36 KA 400 A suitable for Adjustable type setting complete as specified and directed. Make-Legrand, Havells, Schinieder
S & F in replacement MCCB 4 pole 36 KA 315 A suitable for Adjustable type setting complete as specified and directed. Make-Legrand, Havells, Schinieder
Supplying & laying, XLPE insulated PVC inner sheathed, 240 Sqmm, 3.5 core, armoured with galvanised steel strip or wire heavy duty underground cable with aluminium multi stranded conductor, 1100 volt grade, laid in trenches/duct, passing through pipe/duct or fixed on pole and connecting and testing complete all as specified and directed.
All as per item No 37 above but for cable of size 10 sqmm 2 core, complete all as specified and directed.
Taking down defective worm out copper/ aluminium/ GI strip of any size from roof/ wall fixed at a height up to 30m from ground level and making good the disturbed surfaces all as directed by Engineer-in-charge.
S & F aluminium earth strip of size 32 x 6mm complete as earth lead of wall conductors/ buried in ground including screws etc. and connections with existing earth test point complete all as specified and as directed by Engineer-in-charge.
S & F GI earth strip of size 32 x 6mm complete as earth lead of wall conductors/ buried in ground including screws etc. and connections with existing earth test point complete all as specified and as directed by Engineer-in-charge.
Removing existing GI earth strip of size 32 x 6mm from roof/ vertical surfaces of any place up to 30m height from ground level and refixing the same in its original location with fixing accessories after cleaning and straightening the conductor properly all as directed by Engineer-in-charge.
M&L for PCC blocks of size 150mm x 150mm x 75mm with 1:2:4 type B0 (using 12.5mm graded stone aggregate) including teak wood blocks of size 70 x 70 x 30mm duly embedded in PCC block all as directed by Engineer-in-charge.
Disconnecting and dismantling existing unserviceable test point and supplying and fixing new test point terminal block made of phosphorus bronze of 75 x 75 x 25mm, drilled and screwed with 3 Nos of nuts & bolts 8mm dia, 25mm long and connection complete all as directed by Engineer -in-Charge.
Disconnecting and dismantling existing unserviceable Air termination rod and supplying & fixing new single pointed copper rod 12mm dia, 300mm long with all connections with bolts and nuts complete all as specified and as directed.
M&L for carrying out repairs to existing earthing including dismantling the damaged earth chamber complete and provision of new earth chamber including provision of funnel, chamber cover replacement of rusted nut bolts, and GI earth strip from earth electrode to earth test point all as directed by Engineer-in-charge.
Pollution testing carried out of DG sets capacity 12.5 KVA to 160 KVA from authorised Pollution Control Board agency including providing test certificate complete all as specified and directed by Engr-in-Charge.
NOTE :- SCHEDULE OF CREDIT (Amount shall be deducted offline from the total quoted amount to workout the net contract sum to be considered for acceptance.) [(-) Rs 16040.00 /- ]
M/S SHIVA TRADERS
m/s mahendra kumar khare contractor
shubhanshu traders
AUTOMATION AND SWITCHGEAR CONTROL
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .