Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.5 LAdmitted-Finance | ₹28.5 L | L1 | Admitted-Finance |
| 2 | L2₹36.8 LAdmitted-Finance | ₹36.8 L | L2 | Admitted-Finance |
| 3 | L3₹38.0 LAdmitted-Finance 114 BARH CHONDI TOWN BARH DISTT PATNA BIHAR PIN 803213 | PATNA | BIHAR | 803213 | ₹38.0 L | L3 | Admitted-Finance |
| 4 | L4₹47.2 LAdmitted-Finance H NO HDLX 31 DHANWANTRI NAGAR BESIDE JASUJA CITY JABALPUR MP 482003 | JABALPUR | MADHYA PRADESH | 482003 | ₹47.2 L | L4 | Admitted-Finance |
| Sl No | Description | Qty | Unit | MAA SHARDA CONSTRUCTION L3 | ANAMIKA CONSTRUCTION L4 | GIR RAJ BUILDERS L2 | SMART TECH L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling of steel poles/struts of any size complete all as specified and as directed. | 10 | Each | 225 ₹2,250 | 400 ₹4,000 | 1,000 ₹10,000 | 200 ₹2,000 |
| 2.00 | Taking down old UNSV earthing of any type any size complete all as specified and as directed. .
Note: Excavation & earth work where required shall be measured & paid separately under relevant items. | 10 | Each | 125 ₹1,250 | 25 ₹250 | 1,000 ₹10,000 | 500 ₹5,000 |
| 3.00 | Taking down of old unsv cable of any type and any size for repair or replacement incl pipes & bricks etc complete all as specified and directed by engr-in-charge.
Note: Excavation & earth work where required shall be measured & paid separately under relevant items. | 4,550 | RM | 3 ₹13,650 | 5 ₹22,750 | 5 ₹22,750 | 12 ₹54,600 |
| 4.00 | Supply and erecting steel tubular poles complete with cast iron base plate, finial taper plug , bolts Nuts & screws complete all as specified type 410SP 31 of 9 mtr long including painting of pole with one coat red oxide primer & two coats of aluminum paint & emedded portion shall be painted with two coat of black bituminous paint all as specified and directed.
Note : Pole shall be numbered with yellow shade on black base using synthetic enamel paint having height of words exceeding 5 cm complete all as specified and as directed. | 10 | Each | 23,750 ₹2,37,500 | 14,000 ₹1,40,000 | 22,000 ₹2,20,000 | 9,000 ₹90,000 |
| 5.00 | Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level,connected to galvanised iron strip 32×6mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion including the material and labour of the following : -
(a) Excavation and earth work for drilling hole for electrode in any type of Soil.
(b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter.
(c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed
(d) 15 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed.
(e) Requisite quantity of common salt and charcoal.
(f) Testing of earthing. | 10 | Each | 3,000 ₹30,000 | 5,500 ₹55,000 | 5,000 ₹50,000 | 4,500 ₹45,000 |
| 6.00 | Supply , laying and testIng cable XLPE insulated , screened, PVC bedded , galvanized , steel strip or wire armoured, electric power cables ( Heavy duty ) 1100 volts grade with stranded aluminium conductor of size 4 core 10 Sqmm complete all as specified and directed by Engineer in charge | 1,400 | RM | 90 ₹1,26,000 | 100 ₹1,40,000 | 160 ₹2,24,000 | 100 ₹1,40,000 |
| 7.00 | Supply , laying and testIng cable XLPE insulated , screened, PVC bedded , galvanized , steel strip or wire armoured, electric power cables ( Heavy duty ) 1100 volts grade with stranded aluminium conductor of size 4 core 16 Sqmm complete all as specified and directed by Engineer in charge | 1,250 | RM | 110 ₹1,37,500 | 145 ₹1,81,250 | 180 ₹2,25,000 | 150 ₹1,87,500 |
| 8.00 | Supply , laying and testIng cable XLPE insulated , screened, PVC bedded , galvanized , steel strip or wire armoured, electric power cables ( Heavy duty ) 1100 volts grade with stranded aluminium conductor of size 4 core 25 Sqmm complete all as specified and directed by Engineer in charge | 1,050 | RM | 115 ₹1,20,750 | 175 ₹1,83,750 | 285 ₹2,99,250 | 180 ₹1,89,000 |
| 9.00 | Supply , laying and testIng cable XLPE insulated , screened, PVC bedded , galvanized , steel strip or wire armoured, electric power cables ( Heavy duty ) 1100 volts grade with stranded aluminium conductor of size 4 core 50 Sqmm complete all as specified and directed by Engineer in charge | 850 | RM | 150 ₹1,27,500 | 290 ₹2,46,500 | 340 ₹2,89,000 | 300 ₹2,55,000 |
| 10.00 | Supply, fixing, connecting and testing of Automatic Street light switch using infrared Sensor based Nature Switch for automatic switching of street lights, Nature switch operation should be based on Natural light lux level. Required illumination level for switching on is < 30 lux and for switching off > 10 lux. The sensor should also have part night operation facility for 4 - 12 hours. The sensor alongwith suitable power contactor, incoming-outgoing MCBs should be enclosed in a pole/wall mounted hensel enclosure made out of Rust proof, electric shock proof, termite proof and FR grade SMC junction box conforming to IP-66, The circuit should be suitable enough to take 8 KW single phase load with contactor 63 Amps conforming to IEC-60947-4-1/IS-13947-4-1 & incoming and outgoing MCBs of rating 63 Amps conforming to IEC-60898/IS-8828 and circuit wiring of minimum 16sqmm coper conductor wire in and including providing of 50x6mm flat iron clamp, necessary nuts and bolts complete incl taking down of existing arrangement complete all as specified and as directed. | 5 | Each | 16,735 ₹83,675 | 16,500 ₹82,500 | 30,000 ₹1,50,000 | 8,000 ₹40,000 |
Tender Value
₹47.6 L
EMD Value
₹95,120
Closing Date
20 Feb 2026, 6:00 pmClosed
GE (West) Jabalpur
Garrison Engineer (West) Jabalpur Supply Marg Post Box No. 54 Jabalpur Cantt-482001 (MP)
SPL REPAIR TO REPLACEMENT EXTERNAL SECURITY/STREET LIGHTS, CABLES, JUNCTION BOXES WITH STEEL TUBULAR POLES AND ALLIED WORKS UNDER AOR OF GE (WEST) JABALPUR
2026_MES_749766_1
8994/E8
Open Tender
Civil Works
180 days
GE (West) Jabalpur
As per tender documents
6 documents required · 6 mandatory
₹500
GE (West) Jabalpur
₹95,120
10 Mar 2026
23 Jan 2026
27 Feb 2026
24 Jan 2026
20 Feb 2026
6 Feb 2026
24 Jan 2026 - 2 Feb 2026
Dismantling of steel poles/struts of any size complete all as specified and as directed.
Taking down old UNSV earthing of any type any size complete all as specified and as directed. . Note: Excavation & earth work where required shall be measured & paid separately under relevant items.
Taking down of old unsv cable of any type and any size for repair or replacement incl pipes & bricks etc complete all as specified and directed by engr-in-charge. Note: Excavation & earth work where required shall be measured & paid separately under relevant items.
Supply and erecting steel tubular poles complete with cast iron base plate, finial taper plug , bolts Nuts & screws complete all as specified type 410SP 31 of 9 mtr long including painting of pole with one coat red oxide primer & two coats of aluminum paint & emedded portion shall be painted with two coat of black bituminous paint all as specified and directed. Note : Pole shall be numbered with yellow shade on black base using synthetic enamel paint having height of words exceeding 5 cm complete all as specified and as directed.
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level,connected to galvanised iron strip 32×6mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion including the material and labour of the following : - (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 15 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing.
Supply , laying and testIng cable XLPE insulated , screened, PVC bedded , galvanized , steel strip or wire armoured, electric power cables ( Heavy duty ) 1100 volts grade with stranded aluminium conductor of size 4 core 10 Sqmm complete all as specified and directed by Engineer in charge
Supply , laying and testIng cable XLPE insulated , screened, PVC bedded , galvanized , steel strip or wire armoured, electric power cables ( Heavy duty ) 1100 volts grade with stranded aluminium conductor of size 4 core 16 Sqmm complete all as specified and directed by Engineer in charge
Supply , laying and testIng cable XLPE insulated , screened, PVC bedded , galvanized , steel strip or wire armoured, electric power cables ( Heavy duty ) 1100 volts grade with stranded aluminium conductor of size 4 core 25 Sqmm complete all as specified and directed by Engineer in charge
Supply , laying and testIng cable XLPE insulated , screened, PVC bedded , galvanized , steel strip or wire armoured, electric power cables ( Heavy duty ) 1100 volts grade with stranded aluminium conductor of size 4 core 50 Sqmm complete all as specified and directed by Engineer in charge
Supply, fixing, connecting and testing of Automatic Street light switch using infrared Sensor based Nature Switch for automatic switching of street lights, Nature switch operation should be based on Natural light lux level. Required illumination level for switching on is < 30 lux and for switching off > 10 lux. The sensor should also have part night operation facility for 4 - 12 hours. The sensor alongwith suitable power contactor, incoming-outgoing MCBs should be enclosed in a pole/wall mounted hensel enclosure made out of Rust proof, electric shock proof, termite proof and FR grade SMC junction box conforming to IP-66, The circuit should be suitable enough to take 8 KW single phase load with contactor 63 Amps conforming to IEC-60947-4-1/IS-13947-4-1 & incoming and outgoing MCBs of rating 63 Amps conforming to IEC-60898/IS-8828 and circuit wiring of minimum 16sqmm coper conductor wire in and including providing of 50x6mm flat iron clamp, necessary nuts and bolts complete incl taking down of existing arrangement complete all as specified and as directed.
Dismantling/ taking down of existing street light switching system and Supply, fixing, connecting and testing of Automatic Street light switch using infrared Sensor based Nature Switch for automatic switching of street lights, Nature switch operation should be based on Natural light lux level. Required illumination level for switching on is < 30 lux and for switching off > 10 lux. The sensor should also have part night operation facility for 4 - 12 hours. The sensor alongwith suitable power contactor, incoming-outgoing MCBs should be enclosed in a pole/wall mounted hensel enclosure made out of Rust proof, electric shock proof, termite proof and FR grade SMC junction box conforming to IP-66, The circuit should be suitable enough to take 15 KW Three phase load with contactor 32 Amps conforming to IEC-60947-4-1/IS-13947-4-1 & incoming and outgoing MCBs of rating 32 Amps per phase conforming to IEC-60898/IS-8828 and circuit wiring of minimum 10sqmm copper conductor wire in and including providing of 50x6mm flat iron clamp, necessary nuts and bolts complete all as specified and as directed.
Supply and fix junction box made out of polycarbonate with IP 55/IP 65 protection of size 200 x 160 x 98 mm, 5 way having terminals for termination of cable with necessary nuts and bolts including -02 Nos polycarbonate cable gland and 01 Nos DIN rail for mounting of MCB and 01 No, MCB SP, 10 KA, 6 Amps and including fixing clamp of FI 50 x 6mm with necessary nuts and bolts complete in and including taking down of existing u/s junction box of any type complete all as specified and as directed.
S&F in replacement 3 Layer PPR Pipe of outer dia 20 mm (PN-16) UV stabilised having thermal stability upto 93 degree centrigrade complete and fixed with the pole by providing FI clamps, nuts and bolts of size 25x25x3mm with nuts & bolts for protection of connecting wires, connection from junction box to light fittings, complete for all as specified and directed.
S&F in replacement of GI pipe bracket ,made out of GI pipe 40mm dia light grade 1.5mtr long bent to the shape 120 degrees angle all as per site requirement including MS clamps made of F1 50x6mm complete with nuts, bolts & washer as per requirement for mounting fittings complete all as specified and directed.
Supply, fixing and connecting, in repair, energy saving and environmental friendly long life LED street light of max 90 Watt, made up of pressure die cast aluminium housing with high efficiency LED as lighting source with separate driver compartment with IP-66 protection and powered by integral, isolated electronic LED driver. The Luminaire shall conform to following technical specifications: (i) IP rating = IP 66 (ii) Power Factor = min. 0.95 (iii) THD = max upto 10 % (iv) CRI = minimum 70 (v) Surge Protection upto 10 kV with in-built SPD (vi) Lumen efficacy of LED >140 lm/W and lumen efficacy of system = min 10000 lm
Supply, fixing and connecting, in repair, energy saving and environmental friendly long life LED street light 70 Watt, made up of pressure die cast aluminium 100 housing with high efficiency LED as lighting source with separate driver compartment with IP-66 protection and powered by integral, isolated electronic LED driver. The Luminaire shall conform to following technical specifications: (i) IP rating = IP 66 (ii) Power Factor = min. 0.95 (iii) THD= max upto 10 % (iv) CRI = minimum 70 (v) Surge Protection upto 10 KV with in-built SPD (vi) Lumen efficacy of LED >140 lm/W and lumen efficacy of system = min 8000 lm
Supply, fixing and connecting PVC insulated, round,sheathed, multicore, industrial flexible cable with bright annealed copper conductor, 1100 volts grade cable of size 1.5sqmm, 3 core as directed & specified.
Trimming of tree branches Clearing of LT/HT line 4 mtr all around by cutting tree branches at ground level of any numbers and any girth on any numbers of conductors/earth wire complete all as specified and directed by Engr in charge.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 sq.mm 2 core nominal cross section in service connections.
Supply and fixing energy saving and environmental friendly long life LED Flood light luminaires, min 14400 system lumen output and max 120 watt, exclusive innovative die cast aluminium IP66 LED Flood light suitable for highlighting architectural facade and general purpose lighting complete all as specified and as directed.
Supply and fixing energy saving and environmental friendly long life LED Flood light luminaires, min 14400 system lumen output and max 150 watt, exclusive innovative die cast aluminium IP66 LED Flood light suitable for highlighting architectural facade and general purpose lighting complete all as specified and as directed.
Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth , for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, laying of cables etc. n exc 10sqm on plan and n exc 1.5m in depth and getting out in any type of soil complete all as specified and as directed.
Excavation in trenches exceeding 1.5m wide and not exceeding 10 Sq.m on plain area and not exceeding 3 m deep in Soft / Loose soil, for foundations, etc. complete all as specified and as directed.
M&L for sand cushioning to underground cable providing with a layer 8 cm before laying and 15 cm after laying, jointing and testing the cable all as specified and directed. Note: Punned thickness of sand shall be measured.
Supply and laying the Brick covering with width equal to length of brick as mechanical protection to cable with well burnt sub class ‘B’ bricks laid dry flat complete all as specified and directed by Engr in charge.
M/L for Removing excavated material to a distance n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and as directed.
M/L for Returning , filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed.
Supply, laying & fixing double wall corrugated (DWC) pipes made of high density polythyline (HDPE) with all accessories i.e. all type of joints, Sockets, Elbows, bends and End caps etc all as specified and directed by Engr in Charge of size 65 mm outer dia and 50 mm inner dia complete all as specified and as directed.
M & L Plain Cement Concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in foundations, fillings and mass concrete complete all as specified and as directed.
M & L Plain Cement Concrete 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed.
M & L Plain Cement Concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in coping of poles and including necessary form work, finished the surfaces even and smooth without using extra cement complete all as specified and directed.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.24 MB
8994GP.pdf
Tender Documents • 0.43 MB
Tender8994SPPS.pdf
Tender Documents • 1.26 MB
BOQ_839699.xls
BOQ • 0.31 MB
SCH8994.pdf
Additional Documents • 0.09 MB
Download all tender documents and submit your bid