| 1 | L1₹8.0 LAccepted-AOC 0 SHOP NO 48 BHAGAT SINGH COMPLEX VYAPAR VIHAR ROAD CAR PLANET VYAPAR VIHAR BILASPUR BILASPUR CHHATTISGARH 495001 | BILASPUR | CHHATTISGARH | 495001 | L1 | Accepted-AOC ok | |
| 2 | L2₹10.4 L+₹1.5 L (16.7%)Rejected-AOC | L2 | Rejected-AOC Not accepted being L2 | |
| 3 | L3₹10.6 L+₹1.7 L (19.0%)Rejected-AOC | L3 | Rejected-AOC Not accepted being L3 | |
| 4 | L4₹11.1 L+₹2.2 L (25.1%)Rejected-AOC HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | L4 | Rejected-AOC Not accepted being L4 | |
| 5 | L5₹11.7 L+₹2.8 L (32.1%)Rejected-AOC H NO 01 MADINA BAGH MEHJOOR NAGAR NEAR HOTEL RAFADA SRINAGAR 190015 J K | BUDGAM | JAMMU AND KASHMIR | 190015 | L5 | Rejected-AOC Not accepted being L5 |
Tender Value
₹12 L
EMD Value
₹24,000
Closing Date
5 Apr 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Partapur
GE Partapur
Maint and repairs to various external electric supply items, LT Panel, under ground cable and other allied works for Partapur area under GE Partapur
2023_MES_585220_1
GE/P-98/2022-23
Open Tender
Civil Works
Item Rate
183 days
GE Partapur
As per tender documents
8 documents required · 8 mandatory
₹500
GE Partapur
₹24,000
Yes
14 Apr 2023
10 Mar 2023
8 Apr 2023
10 Mar 2023
5 Apr 2023
24 Mar 2023
11 Mar 2023 - 14 Mar 2023
Amount
Taking out un-serviceable/faulty cable/service connection cable of any grade / type / class of any size for repair / replacement from pole / wall / cable duct under ground trench etc for re-use or removal from site of work all as specified and as directed by the Engineer-in-charge (Note- Excavation and earth work shall be measured and paid separately)
Supply, laying,fixing, passing through pipe or laid in trenches and testing underground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 2 core 10 sqmm all as specified and directed.
Supply, laying,fixing, passing through pipe or laid in trenches and testing underground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 2 core 16 sqmm all as specified and directed.
Supply, laying,fixing, passing through pipe or laid in trenches and testing underground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 4 core 16 sqmm all as specified and directed.
Supply, laying,fixing, passing through pipe or laid in trenches and testing underground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 4 core 25 sqmm all as specified and directed.
Supply, laying,fixing, passing through pipe or laid in trenches and testing underground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 3.5 core 35 sqmm all as specified and directed.
Supply, laying,fixing, passing through pipe or laid in trenches and testing underground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 3.5 core 50 sqmm all as specified and directed.
Supply, laying,fixing, passing through pipe or laid in trenches and testing underground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 3.5 core 70 sqmm all as specified and directed.
Supply, laying,fixing, passing through pipe or laid in trenches and testing underground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 3.5 core 185 sqmm all as specified and directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtrs in depth for laying of cable, fixing of stay etc 10 Sqm on plan and n exc 1.5 in depth and getting out in hard/dence soil complete all as specified and directed by Engineer-in-Charge.
Returing, filling in incl spreading, levelling watering and well remming in layers n.exc 25cm width, Complete all as specified and directed by Engineer-in-Charge.
Removing excavated soil to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 m above starting point Completed all as specified and diercted by Engineer-in-Charge.
Sand cushioning for under ground cable 8 cm before laying the cable and 15 cm after laying and streching the cable complete all as specified and directed by Engineer-in-Charge.
M&L Un-reinforced precast factory made concreate cable covers, class LV type-I, with flat size 250x150x40 mm Complete all as specified and directed by Engineer-in-Charge.
Supply and laying/fixing, GI pipe medium grade 40 mm bore (dia)including all type fittings fixed on walls/to poles with clamps /laid in trenches as cable protection all as specified and directed.
Supply and laying/fixing, GI pipe medium grade 50 mm bore (dia)including all type fittings fixed on walls/to poles with clamps /laid in trenches as cable protection all as specified and directed.
Supply and laying/fixing, GI pipe medium grade 80 mm bore (dia)including all type fittings fixed on walls/to poles with clamps /laid in trenches as cable protection all as specified and directed.
Supply and fixing Aluminium bus bar chamber 3 phase, 200 Amp capacity with 4 nos Al strips not less than 600 mm long, outdoor type including one MCCB of 125 Amps 4 Pole as incommer with locking arangement, grouting in pcc 1:3:6 and connecting with UG XLPE cable with suitable copper thimbles complete all as specified and directed.
M&L for Earthing complete with galvanized steel earth plate electrode 600x600x6mm thickness not less than 6mm thick buried directly in ground( earth plate not less than 2.25 mtr deep below normal ground level) with top edge of earth plate not less than 2.5 mtr below the normal ground level connected to galvanized iron wire 4 mm dia by means of nuts bolts, nuts, check nuts and washers of GI steel all as shown in electrc plate No 5 connected to earth test point all as specified and indicated complete and including charcoal dust,salt etc and GI protection pipe light grade 40mm bore and GI watering pipe 20mm bore medium grade with funnel and wire mesh ,40mm thick pre cast RCC M-15 ( Nominal mix) cover reinforced with XPM weight not less than 4 Kg/Sqm with suitable handle of 6mm dia MS bar and angle iron 40X40X3mm frame for cover,PCC M-15 ( Nminal mix) pit, excavation and earth work in any type of soil and connected all as specified and as directed by Engineer-in-charge.
M&L for Earthing complete with galvanized steel earth plate electrode 600x600x6mm thickness not less than 6mm thick buried directly in ground( earth plate not less than 2.25 mtr deep below normal ground level) with top edge of earth plate not less than 2.5 mtr below the normal ground level connected to galvanized iron earth strip of size 32 x 6 mm thick by means of nuts bolts, nuts, check nuts and washers of GI steel all as shown in electrc plate No 5 connected to earth test point all as specified and indicated complete and including charcoal dust,salt etc and GI protection pipe light grade 40mm bore and GI watering pipe 20mm bore medium grade with funnel and wire mesh ,40mm thick pre cast RCC M-15 ( Nominal mix) cover reinforced with XPM weight not less than 4 Kg/Sqm with suitable handle of 6mm dia MS bar and angle iron 40X40X3mm frame for cover,PCC M-15 ( Nminal mix) pit, excavation and earth work in any type of soil and connected all as specified and as directed by Engineer-in-charge.
S&F MCCB 4 Pole, 415 V, 63 Amps with breaking capacity 16 KA, adjustable type complete all as specified and directed by Engr-in-Charge.
S&F MCCB 4 Pole, 415 V, 100 Amps with breaking capacity 16 KA, adjustable type complete all as specified and directed by Engr-in-Charge.
S&F MCCB 4 Pole, 415 V, 125 Amps with breaking capacity 16 KA, adjustable type complete all as specified and directed by Engr-in-Charge.
S&F MCCB 4 Pole, 415 V, 160 Amps with breaking capacity 36 KA, adjustable type complete all as specified and directed by Engr-in-Charge.
S&F MCCB 4 Pole, 415 V, 200 Amps with breaking capacity 36 KA, adjustable type complete all as specified and directed by Engr-in-Charge.
S&F MCCB 4 Pole, 415 V, 250 Amps with breaking capacity 36 KA, adjustable type complete all as specified and directed by Engr-in-Charge.
S&F MCCB 4 Pole, 415 V, 400 Amps with breaking capacity 36 KA, adjustable type complete all as specified and directed by Engr-in-Charge.
Supply and fix ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 63 Amps all as directed and specified.
Supply and fix ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 160 Amps all as specified and directed.
Supply and fix ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 200 Amps all as specified and directed by engr-in-charge. Make- Euroload
Supply and fix ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 400 Amps all as specified and directed by engr-in-charge. Make- Euroload
Material and Labour for PCC 1:3:6 type C-2 using 40mm graded crushed stone aggregate as in foundation, filling or mass concrete as in foundation stays etc complete all as specified and directed by Engr-in-Charge.
Supply and installation erection commissioning and testing of main LT pannel cubical out door type weather/dust proof, factory made out of 3.15 mm thick CRCA sheet powder coated with front and back side openable with suitable cable alley and front side shutter with locking arrangement panel base of angle iron 50x50x6mm upto 45 cm height for 433 volts, 3 phase, 4 wire system including four pole aluminium bus bar 400 Amps capacity including control wiring with suitable size of PVC insulated standed copper conductor and incoming/outgoing connection with aluminium bus bar complete as per manufacture design complete mounted or fixed on PCC foundation above 0.45 mtr on floor and cable connection with suitable size of aluminium lugs and glands complete comprising the following:-
MS Sheet body of LT Panel With double door angle iron frame
Incomming
(a) MCCB, 250Amps, 36 KA Optium 1.0 (Fixed TM range) 4 pole Make : INDOASIAN Cat No 830116-01 Nos
Outgoing
(b) MCCB, 125 Amps, 25 KA, Optium 1.0 (Fixed TM range) 4 pole Make : INDOASIAN Cat No 830050-01 Nos
(b) MCCB, 63 Amps, 16 KA, Optium 1.0 (Fixed TM range) 4 pole Make : INDOASIAN Cat No 830050-01 Nos
(d) MCCB, 25 Amps, 16 KA, Optium 1.0 (Fixed TM range) 4 pole Make : INDOASIAN Cat No 830016-01 Nos
(e) MCCB, 16 Amps, 10 KA, Optium 1.0 (Fixed TM range) 4 pole Make : INDOASIAN Cat No 830710-01 Nos
(f) LED type phase indicattor lamp (R Y B) - 01 Set
(j) Change over 200 Amps Make : INDOASIAN Cat No IN10A200-01 Nos
Deduct Schedule of Credit of Rs (-) 89425.00 (Minus) as listed in Schedule 'A' Part-II. Contract Sum shall be arrived after deducting the credit amount. Note :- Tenderers will not quote against this item being a firm amount.
BETONG BUILDERS
HEENA CONSTRUCTION CO
national engineering
M/S BALI CONSTRUCTIONS
M/S SOHUM ENGINEERS
darshan kumar gandhi
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .