GE (AF) Leh
GE (AF) Leh C/O 56 APO
CERTAIN REPAIR OF WSA BUILDINGS AT AF STN LEH UNDER GE (AF) LEH
2022_MES_560435_1
GE(AF)/LEH/T-29/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) Leh
As Per Tender documents
8 documents required · 8 mandatory
₹500
GE (AF) Leh
₹20,000
Yes
30 Dec 2022
29 Oct 2022
28 Nov 2022
29 Oct 2022
26 Nov 2022
12 Nov 2022
Amount
Material and labour for point wiring in steel conduit unsheathed multistrand copper conductor cable of 1.5 sqmm single core FRLS for one light/fan point controlled by one flame proof switch including continuouse earth continuity copper earth wire of same size connected to common earth dolly, complete all as specified and directed by Engr-in-charge. Note : (a) wiring shall be done by using proper colour coding.
Switch flame proof rotary type with termination box in LM6, 16 Amps, single pole 250 volts, complete all as specified and directed by Engineer-in-Charge
Flame Proof LED light fitting 2x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver,holders, onnector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size, complete all as specified and directed by Engineer-in-Charge
Flameproof exhaust fan of size 450mm sweep including lowers with IP-66 protection, complete with all accessories pre-wired and connecting up with twin core twisted flexible copper conductor wire of suitable size, complete all as specified and directed by Engineer-in-Charge
Cutting openings, through brick/stone walls built in cement mortar for exhaust fans of 450mm sweep and other openings, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core etc. to store and rubbish not exc. 50m, including forming jambs in CM 1:4 and making good to match existing wall finishes, complete all as specified and directed by Engineer-in-Charge
Ceiling rose 3 terminal size 50x65mm surface type 230 volts, complete all as specified and directed by Engineer-in-Charge
Sub main wiring with two single core 4 Sqmm FRLS steel conduit insulated and unsheathed 1100 volts grade cables with stranded copper conductor cable drawn through in and including steel conduit casing caping and accessories including one single core 4 Sqmm FRLS steel conduit insulated unsheathed stranded copper earth cable connected to common earth dully complete in and including taking down of old unservicable sub main wiring, complete all as specified and directed by Engineer-in-Charge. Note : (i) 2 run of 4 Sqmm ,1 run of steel conduit casing caping & 1 run of 4 Sqmm earth cable will be measured as single run. (ii) Extra length of cables/wire required for connection to MCBs shall not be measured and paid separetly the rate quoted by contractor per unit shall be deemed to be included in the quoted rate of this item.
Flame proof SPN DB's SPN 8 way 240 V having suitable rated bus bar, complete all as specified and directed by Engineer-in-Charge
MCB SPN, 32 Amps, 240 Volts ,10 KA to be housed in DBs Proper and suitable size cable lugs to be fixed with MCBs as in replacment ,complete all as specified and directed by Engineer-in- Charge.
MCB SP, 6 to 32 Amps, ,240 Volts ,10 KA to be housed in DBs of Proper and suitable size cable lugs to be fixed with MCBs as in replacment ,complete all as specified and directed by Engineer-in- Charge.
Earthing complete with Galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm burried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to G I earth strip 4 dia G I wire by means of brass bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6), type C-1 chamber, pit cover of precast RCC (1:2:4), type B-1, reinforced XPM of weight not less than 4 kg/ Sq.m and MS frame etc. in and including taking down of old unserviceable earthing, complete all as specified and as directed by Engineer-in-Charge. Note :- (i) The unit rate includes earth lead and protection pipe up to maximum 7.5 metre from earth plate to earth point/test point. (ii) Earth pit shall be constructed minimum 0.5 metre away from earth.
Note : Schedule of credit to be deducted on acceptances of bid.Details of Schedule of credit is given in tender documents
osho traders
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .