Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.4 LAccepted-Finance | L1 | Accepted-Finance Being L1 bidder | |
| 2 | L2₹39.5 L+₹5.1 L (14.7%)Rejected-Finance | L2 | Rejected-Finance Not being L1 bidder | |
| 3 | L3₹39.6 L+₹5.2 L (15.0%)Rejected-Finance | L3 | Rejected-Finance Not being L1 bidder | |
| 4 | L4₹39.8 L+₹5.3 L (15.5%)Rejected-Finance | L4 | Rejected-Finance Not being L1 bidder | |
| 5 | L5₹40.8 L+₹6.4 L (18.5%)Rejected-Finance | L5 | Rejected-Finance Not being L1 bidder |
Tender Value
₹41.7 L
EMD Value
₹83,500
Closing Date
2 Apr 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER SOUTH UDHAMPUR
Udhampur
SPL REPAIR TO BLDG NO P 74 OR MD ACCN AT 3 ASD UNDER GE SOUTH UDHAMPUR
2025_MES_700255_1
GE/S(U)- /2024-25
Open Tender
Civil Works
Works
240 days
GE SOUTH UDHAMPUR
As per NIT
9 documents required · 9 mandatory
₹500
GE SOUTH UDHAMPUR
₹83,500
30 Apr 2025
5 Mar 2025
9 Apr 2025
5 Mar 2025
2 Apr 2025
19 Mar 2025
Amount
Demolition of reinforced cement concrete in roof floor (other than ground floors) beams staircase, landing chajja and similar work complete all as specified and directed by Engr In charge/GE.
Demolition of concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed by Engr In charge/GE.
Dismantling floor, hearth or wall tilling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish of the premises, complete all as specified and directed by Engr In charge/GE.
M&L for glazed coloured ceramic tiles in dado/vertical surface size 600mmx300mmx8-9mm thick set and jointed in neat cement slurry and pointed in coloured cement to match the surface including 10 mm thick rendering as backing coat to receive the tiles on fair faces of brick /concrete surfaces in cement mortar 1:3 and finished even and rough complete all as specified and directed by Engr In charge/GE.
M&L Non - Skid Ceramic tiles (square/rectangular) (size 300x300x10mm thick joint free)area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thich screed bed or bedding layer in cement mortar (1:4) etc complete all as specified and directed by Engr In charge/GE.
M&L for Non skid coloured tiles (square/rectengular) (size 600x600x8-9mm thick joint free) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface including 15mm thich screed bed or bedding layer in cement mortar (1:4) etc complete all as specified and directed by Engr In charge/ GE.
-------ditto ----- but on vertical surfaces as in skirting including 8-9 mm thick rendering as backing coat to receive the tiles on fair faces of brick /concrete surfaces in cement mortar 1:3 and finished even and rough complete all as specified and directed by Engr In charge/ GE.
M&L for 25mm thick cement concrete 1:2:4 type B-0 using 12.5mm graded crushed stone aggregates as in floor and finished even and fair complete all as specified and directed by Engr In charge/ GE.
M&L for Machine cut kota stone slab flooring 18-20mm thick (size 600mmx600mm) over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including 20mm thich screed bed or bedding layer in cement mortar (1:4), rubbing and polishing and moulding etc.complete all as specified and directed by Engr In charge/ GE. Note: Kota stone should be laid on stair in one piece.
M&L for machine cut kota stone 18-20 mm thick in riser (size 1000mmx300mm joint free) of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including 15mm thich cement screed or bedding layer in cement mortar (1:4), rubbing and polishing etc. complete all as specified and directed by Engr In charge/ GE. Note: Kota stone should be laid on stair in one piece.
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed by Engr In charge/ GE. .
M&L Granite slab 16 to 18 mm thick as in pillars, window cill, cooking platform and the like in cement motar 1:4 including painting in white cment 1:2 using marble dust with a mixture of pigment to match the shade of granite including cutting polishing and moulding on edges, complete all as specified and directed by Engr In charge/ GE.
M&L for Rendering 15mm thick on brick work or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement including mixing integral water proofing compound in the proportion as mentioned in manufacturer's instructions complete all as specified. (Water proofing compound to be measured and paid for separately), complete all as specified and directed by Engr In charge/ GE.
M&L for Rendering 10mm thick on brick work or concrete surface in cement mortar 1:6 finished even and smooth without using extra cement , complete all as specified and directed by Engr In charge/ GE. .
M&L for Rendering 5mm thick on brick or concrete surface as in ceiling in cement mortar 1:3 finished even and smooth without using extra cement, complete all as specified and directed by Engr In charge/ GE.
Supply only integral water proofing compound complete all as specified and directed by Engr In charge/ GE.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 Square Metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt ), all as specified and directed by Engineer-in Charge.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area exceeding 1.50 square metre and not exceeding 4.0 square metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.), all as specified and directed by Engineer-in Charge.
M&L for pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc. complete , of frame size 125 x 60 mm, including one shop coat of red oxide zinc chrome primer complete all as specified and directed by Engr In charge/ GE.
M&L for pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc. complete , of frame size 105 x 60 mm, including one shop coat of red oxide zinc chrome primer complete all as specified and directed by Engr In charge/ GE.
M&L for providing cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregates for filling in the pressed steel door frame/hold fast complete all as specified and directed by Engr In charge/ GE.
M&L for factory made, 2nd class hard wood 30 mm thick, plain framed, Flush shutters solid core constraction, with block board core and plywood face panels, commercial type on both sides coverd with decorative face vaneer with lipping / frame to match complete all as specified and directed by Engr In charge/ GE.
S&F factory made, 2nd class hard wood 35 mm thick glazed and skelton shutter open rebated and prepared to receive glass, gauge etc (without sash bar) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass/ gauge etc complete all as specified and directed by Engr In charge/ GE.
S&F steel window (box type) factory made with side hung shutters including pintol hinges, steel handles, steel peg stay and all locking arrangement complete with glazing bars dovetailed or welded including one shop coat of red oxide primer complete all as specified and directed by Engr In charge/ GE. Note : i) The window shall be fabricated as per Drg No CEUZ/TD/1269/2008 Sheet 1/3 to 3/3 ii) MS fillets, glazing, wire gauge shall be measured and paid separately.
Description all as per item as above here in before but without glazing bar complete all as specified and directed by Engr In charge/ GE. Note : i) The window shall be fabricated as per Drg No CEUZ/TD/1269/2008 Sheet 1/3 to 3/3 ii) MS fillets, glazing, wire gauge shall be measured and paid separately
S&F factory made mild steel ventilators box type with upper top hung shutters and bottom fixed type shutters including pintol hinges,steel peg stay and one shop coat of red oxide primer complete all as specified and directed by Engr In charge/ GE. Note :- i) The window shall be fabricated as per Drg No CEUZ/TD/1302/2009 Sheet 1/3 to 3/3 ii) MS fillets, glazing, wire gauge shall be measured and paid separately
Mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bar; barred iron doors; ladder; framed balusters; railing;frame work for water tanks and similar work conforming to Fe 290 Gd E-165 complete all as specified and directed by Engr In charge/ GE.
S&F 4 mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads in squares not exceeding 0.50 Sqm in each pane complete all as specified and directed by Engr In charge/ GE.
S&F 4 mm thick sheet glass frosted ordinary quality and glazing with oil putty or wooden beads in squares not exceeding 0.50 Sqm in each pane complete all as specified and directed by Engr In charge/ GE.
S&F stainless steel wire cloth 0.36mm nominal and average width of apreture 1.40mm and fixed with tinned teaks or wire staple complete all as specified and directed by Engr In charge/ GE.
M&L for rolled mild steel work of angle iron as in frames of doors & Cup Board etc conforming to grade Fe 410-O or Fe-310-O complete all as specified and directed by Engr In charge/ GE.
S&F Hard Drawn steel wire fabric cut to length bent to shape required and tying,welding to the angle iron frame etc complete all as specified and directed by Engr In charge/ GE.
S&F 19mm thick ISI, termite proof , chemically well pressed, HDHMR board exterior grade prelaminated, one side with decorative choice lamination and other side balancing white lamination fixed with screws to frame work for kitchen cabinetstand cup boards etc includimg 6mm thick wood beading all around complete all as specified and directed by Engr In charge/ GE. Make :- Win Tuff or its equevelent
Demolition of brick/stone masonry built in CM. complete all as specified and directed by Engr In charge/ GE.
M&L for Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted built in cement mortar 1:6 complete all as specified and directed by Engr-in-charge. Note PCC Bond Stone shall be paid separately under appropriate item and volume of bond stone shall be deducted, complete all as specified and directed by Engr In charge/ GE.
All as per item No 35 above but except stone, complete all as specified and directed by Engr In charge/ GE.
M&L for Precast cement concrete Block (1:3:6) type C-1 (using 20mm graded crushed stone aggregate) as in bond stones set in cement mortor 1:6 complete all as specified and directed by Engr In charge/ GE.
Extra over stone walling for hammer dressing with miximum depression on face from straight edge held against the dressed surface not exceeding 20 mm to face stones (Granite or Trap stone) and dressing of face beds and joints, as specified of random rubble walling, uncoursed or brought upto courses complete all as specified and directed by Engr In charge/ GE.
M&L Flush pointing to random rubble masonry in CM (1:4), uncoursed or brought upto courses complete all as specified and directed by Engr In charge/ GE.
M&L brick work with sub class B bricks straight or curved on plan to any radius built in CM 1:6 complete all as specified and directed by Engr In charge/ GE.
M&L brick work with sub class B bricks straight or curved on plan to any radius built in CM 1:6 but except bricks complete all as specified and directed by Engr In charge/ GE.
M&L half brick work with sub class B bricks straight or curved on plan to any radius built in CM 1:4 complete all as specified and directed by Engr In charge/ GE.
M&L Providing cement concrete in steps, seismic and other similar bands, parapets and railings up to 60 cm in hieght, coping, kneeless apex stones , bed plates, kerbs not provided for including weathering, slightly rounded or chamfered angles 1:2:4 mix type B-0, complete all as specified and directed by Engr In charge/ GE.
Roughing surfaces of old conc surfaces by picking up , sweeping,cleaning and washing down with water to remove dust etc including taking down tarfelt and brushing neat cement slurry @3kg/Sqm including 20mm thick screeding in CM (1:4) finished even and smooth mixed with water proofing compound (WPC shall be measured and paid separatley), complete all as specified and directed by Engr In charge/ GE.
M&L Applying bituminous primer on roof surfaces @ 0.40 ltr/Sqm and applying one coat of hot blown bitumen of grade 85/25 @ 1.20 Kg/Sqm and laying polymeric water proofing membrane 3 Kg/Sqm and bonded completely to the surfaces with overlap of 10 cms (overlaps to be thermo fused by flame) and applying one coat of hot blown bitumen 85/25 @ 0.70 Kg/Sqm complete all as specified and directed by Engr In charge/ GE. Make: STP/IWL
M&L for providing 50 mm thick cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregates as in plinth protection finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified and directed by Engr In charge/ GE.
S&F stainless stell, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed by Engr In charge/ GE.
S&F continuous MS CP piano type hinges 30mm flap (when opened), bright finish or electrogalvanised complete all as specified and directed by Engr In charge/ GE.
S&F stainless stell, cast type, 150 mm long complete all as specified and directed by Engr In charge/ GE.
S&F 100mm size hasp and staple safty type aluminum anodized with mild steel hinges pin including bolt to hinge plate and fixed with screw complete all as specified and directed by Engr In charge/ GE.
S&F for 150mm size stainless steel anodised barrel tower bolt of extruded section and fixed, complete all as specified and directed by Engr In charge/ GE.
S&F for 150mm size staintless steel handle of febricated type and fixed complete all as specified and directed by Engr In charge/ GE.
S&F Second class hard wood small fittings such as brackets of any type, shaped door and window stops and the like including all necessary Labour; articles not exceeding 200 Cu.Cm each.
Supply and fixing of mild steel cold rolled butt hinges medium weight 100 mm log fixed to steel /angle iron frame by welding ,if required complete all as specified and directed by Engr In charge/ GE.
Supply and fixing of mild steel cold rolled butt hinges medium weight 75 mm log fixed to steel /angle iron frame by welding ,if required complete all as specified and directed by Engr In charge/ GE.
Supply and fixing of mild steel cold rolled butt hinges medium weight 50 mm log fixed to steel /angle iron frame by welding ,if required complete all as specified and directed by Engr In charge/ GE.
S&F 250 mm mild steel ordinary rat tail rod pattern springs, including roller and roller plate complete all as specified and directed by Engr In charge/ GE.
S&F stainless steel barrel tower bolts, ISI marked with bright bolt with bright bolt 200mm long, complete all as specified and directed by Engr In charge/ GE.
S&F harrison curtain rails, Stainless steel,25 mm dia chromium plated with fixing brackets, stops, rollers etc. complete all as specified and directed by Engr In charge/ GE.
S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, in opening as per specifiecation and drawings, complete all as specified and directed by Engr In charge/ GE.
S&F factory made solid panel PVC door shutter 30mm thick style consisting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width struck inside with solvent cement forstyle and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the styles & rails with suitable PVC sheet beading and jointed together with solvent cement supply & fixing in the frame at site, complete all as specified and directed by Engr In charge/ GE.
S&F vitreous China wash basin corner, white, flat back, size 550x400mm excluding tap, chain, plug but including brackets, waste fitting 32mm dia ,brass chromimium plated for glazed ware sink, basin,with long screwed shanks and fly nuts flange end bedded in red lead cement and other end fixed complete all as specified and directed by Engr In charge/ GE.
M&L for preparation of wooden surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed by Engr In charge/ GE.
M&L for preparation of steel and iron surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over a coat of primer, complete all as specified and directed by Engr In charge/ GE.
M&L for applying two coats of white washing on ceiling including preparation of new/old plastered surfaces complete all as specified and directed by Engr In charge/ GE.
M&L two coats of oil bound distemper on walls including preparation on new/old surfaces including applying 1 mm thick layer of wall putty on walls to give uniform surface complete all as specified and directed by Engr In charge/ GE. Note :- (Before applying of wall care putty, complete removing of treatment as directed and approved by Engr-in-charge).
M & L for preparation of complete removal of new /old decorated surfaces of walls including brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil, greasy spots and applying Two or more coats of 100% Premium acrylic emulsion paint on external surface having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces, complete all as specified and directed by Engr In charge/ GE.
S&F water closet (Orissa pattern) including lime concrete bedding, vitreous china long pan orissa pattern 580x440mm, white with integral foot rests (excluding flushing cistern & flush pipe) fixed in repairs, complete all as specified and directed by Engr In charge/ GE.
Supply only PVC (SWR) 'P' trap 110mm dia, complete all as specified and directed by Engr In charge/ GE.
S&F in repair 10 ltr PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, complete all as specified. Make CERA/Prayag or equivalent.
Supply only flush pipe of PVC 32 mm dia for low level cistern. complete all as specified and directed by Engr In charge/ GE.
S&F MS grating 100mm dia fixed to floor trap in repair, complete all as specified and directed by Engr In charge/ GE.
M&L 600 mm long brass chromium plated towel rail fancy type in repair complete all as specified and directed by Engr In charge/ GE. Make : Jaquar Cat Part No ACN-1111NM and equivalent in Hindware/CERA.
S&F PVC connection 15mm size with PTMT nuts of lengh 450mm complete all as specified and directed by Engr In charge/ GE.
S&F steel peg set colour coated of six as per sample, complete all as specified and directed by Engr In charge/ GE.
S&F Stainless steel sink with draining board, made out of 1.00mm thick sheet for kitchen or laboratory with plug, washers waste pipe, cast iron cantilever brackets, connecting union overall size 915mmx460mm with bowl size 410mm x 330mm x 160mm, complete all as specified and directed by Engr In charge/ GE.
S&F plate rack made of stainless steel, 600 x 750X0.55mm including fixing as per manufacturers instruction, complete all as specified and directed by Engr In charge/ GE.
M&L PCC 1:3 :6 type C2 using 40 mm graded aggregate in surafce channel and drains complete all as specified and directed by Engr In charge/ GE.
M&L PCC 1:5:10 type E2 using 40 mm graded brick aggregate as in filling under sunken floors etc complete all as specified and directed by Engr In charge/ GE.
Dismantling cast iron pipe & reinforced concrete drain pipes, jointed in cement mortar of any dia upto 100mm. complete all as specified and directed by Engr In charge/ GE.
PVC (SWR) pipes 75 mm bore single socketed, in any length with rubber ring joints fixed to wall/ floor complete all as specified and directed by Engr In charge/ GE.
S&F Cast iron bend (any radius) diminishing pieces or tapers 75mm bore fitted with oval access door, complete all as specified and directed by Engr In charge/ GE.
S&F Stack clamps made out of 50mm by 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 100/110mm bore pipe, complete all as specified and directed by Engr In charge/ GE.
S&F Stack clamps made out of 50mm by 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 75 mm bore complete all as specified and directed by Engr In charge/ GE.
S&F PVC branch pieces single (equal unequal ordinary or inverted (Spigot or socketed type) or with parelled branches 75mm bore (fixed in repairs), complete all as specified and directed by Engr In charge/ GE.
S&F PVC branch pieces single (equal unequal ordinary or inverted (Spigot or socketed type) or with parelled branches 100mm bore (fixed in repairs) complete all as specified and directed by Engr In charge/ GE.
PVC (SWR) pipes 110mm bore single socketed , in any length with rubber ring joints fixed to wall/ floor, complete all as specified and directed by Engr In charge/ GE.
S&F PVC (SWR) bend any radius for 110mm bore pipe, complete all as specified and directed by Engr In charge/ GE.
S&F PVC vent cowl for 75m dia pipe, complete all as specified and directed by Engr In charge/ GE.
S&F PVC vent cowl for 50m dia pipe, complete all as specified and directed by Engr In charge/ GE.
S&F PVC floor trap 75 mm, with grating including jointing to waste pipe, complete all as specified and directed by Engr In charge/ GE.
S&F PVC work in lids for oval access doors for 75mm bore pipes and fittings including all necessary threading and nut/bolt required complete all as specified and directed by Engr In charge/ GE.
S&F PVC work in lids for oval access doors for 100mm bore pipes and fittings including all necessary threading and nut/bolt required, complete all as specified and directed by Engr In charge/ GE.
M&L for Reinforced cement concrete (Nominal Mix) type B1 1:2:4 using 12.5mm graded stone aggregate as chajjas or similar works etc complete all as specified and directed by Engr In charge/ GE.
Taking up or down 15mm Bore, steel tubing with connections for cleaning for refixing or removing to store yard complete all as specified and directed by Engr In charge/ GE.
Taking up or down 20mm Bore, steel tubing with connections for cleaning for refixing or removing to store yard complete all as specified and directed by Engr In charge/ GE.
M&L 15/20mm bore galvanised steel water tubing medium grade 15 mm dia (ISI Marked) with all fittings and fixed complete to walls and or laid under floors etc complete all as specified and directed by Engr In charge/ GE.
M&L 15/20mm bore galvanised steel water tubing medium grade 20 mm dia (ISI Marked) with all fittings and fixed complete to walls and or laid under floors etc complete all as specified and directed by Engr In charge/ GE.
M&L Gun metal globe of gate valve with iron wheel head, screwed both ends of size 20mm, complete all as specified and directed by Engr In charge/ GE.
M&L Gun metal globe of gate valve with iron wheel head, screwed both ends of size 15mm, complete all as specified and directed by Engr In charge/ GE.
S&F fancy type chromium plated angle valve cast copper alloy, screwed down, high pressure, with crutch or but-terfly handle, screwed both ends for iron pipe or for unions chromium plated of size 15 mm, complete all as specified and directed by Engr In charge/ GE.
S&F fancy type chromium plated bid tap cast copper alloy, screwed down, high pressure, with crutch or but-terfly handle, screwed both ends for iron pipe or for unions chromium plated of size 15 mm, complete all as specified and directed by Engr In charge/ GE.
S&F Ball Brass Valve high pressure with polythine coat and fly nut complete screwed for Iron pipe or brass ferrule and fixed of size 20mm bore, complete all as specified and directed by Engr In charge/ GE.
M&L in repairs brass chromium plated shower rose 125mm size with swivel joint fixed to pipe or union of 15mm bore, complete all as specified and directed by Engr In charge/ GE.
Dismantling water tanks and removing to store exc 500 & n.exc 1000 ltrs of capacity, complete all as specified and directed by Engr In charge/ GE.
S & F in repairs 15 mm dia WHB mixer centre hole chromium plated screwed down high pressure with crutch or butterfly handle screwedboth ends for iron pipes or for unions and fixed complete all as specified and directed by Engr In charge/ GE. Make - Jaquar Cat No KUP-35011BPM or equivalent in Hindware
S &F sheet glass shelf assembly/corner consisting of 5.5 mm thick sheet glass shelf 12 cm wide with chromium plate bracket guard and railing 60 cm long in repair, complete all as specified and directed by Engr In charge/ GE.
S&F rotational moulded polyethylene water storage tanks ( cylindrical vertical with thread closed top) hoisted white colour and fixed in position all as specified in SSR Part-I of capacity 1000 liters including all accessories complete all as specified and directed by Engr In charge/ GE.
S&F in repair Soap dish, any type, fixed to plugs with chromium plated brass screws complete all as specified and directed by Engr In charge/ GE.
S & F in repairs 15 mm dia wall mixer chromium plated screwed down high pressure with crutch or butterfly handle screwedboth ends for iron pipes or for unions and fixed complete all as specified and directed by Engr In charge/ GE. Make - Jaquar Cat No FON-40119 or equivalent in Hindware
Demolition of cement concrete (unreinforced) in ground floor and in paving not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed by Engr In charge/ GE.
M&L, Hard core of broken stone or boulders of gauge exc 63 mm but n exc 100 mm deposited spread and levelled in layers n exc 15 cm thick watered and rolled / rammed to a true surface, complete all as specified and directed by Engr In charge/ GE.
M&L for PCC 1:4:8 Type D2 using 40 mm graded stone aggregates as in foundations filling and mass concrete, complete all as specified and directed by Engr In charge/ GE.
M&L for sand cushion 25 mm thick for laying and fixing interlocking tiles, complete all as specified and directed by Engr In charge/ GE.
M&L for 60mm thick machine pressed / vibro mechanically floated interlocking paver block any shape and size conforming to IS - 15658-2006, M-35 grade, with topping of cement mixed without pigment. Colour and shape shall be approved by Engr-in-charge. (Make: ULTRA/MODERN/RUCHI/ISI Marked).
M&L Providing cement concrete in steps, seismic and other similar bands, parapets and railings up to 60 cm in height, coping, kneeless apex stones , bed plates, kerbs not provided for including weathering, slightly rounded or chamfered angles all as directed, 1:2:4 mix type B-0 (12.5mm graded aggregate) complete all as specified and directed by Engr In charge/ GE.
Demolition and breaking up drain pipes 150/200mm (Salt glazed ware, AC or Reinforced concrete) set in cement mortar, complete all as specified and directed by Engr In charge/ GE.
Brick work with sub-class 'B' bricks in one brick thick honey comb walling, built in cement mortar 1:6 complete all as specified and directed by Engr In charge/ GE.
Excavating over area , exc 1.5 deep and getting out in any type of soil, complete all as specified and directed by Engr In charge/ GE.
Excavating in trenches, n exc 1.5 m wide and n.exc 1.5 m in depth; for foundation, & n exc 10 Sqm on plan and n exc 1.5 m in depth and getting out in any type of soil, complete all as specified and directed by Engr In charge/ GE.
Returning, filling incl spreading leveling watering and well ramming in layers not exceeding 25mm in any type of soil, complete all as specified and directed by Engr In charge/ GE.
Removing excavated material (soils) exceeding 250 m but n.exc. 500m and depositing where directed at a level not exceeding 1.5m above the starting point, complete all as specified and directed by Engr In charge/ GE.
Brick work with sub-class 'B' bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:4 complete all as specified and directed by Engr In charge/ GE.
M&L for 15mm thick rendering on fair faces of brick work or concrete surfaces in cement motor 1:4 and finished even and smooth without using extra cement complete all as specified and directed by Engr In charge/ GE.
M&L for PCC 1:2:4 type B1 (using 20 mm graded aggregate) in surafce channel and drains complete all as specified and directed by Engr In charge/ GE.
Providing Precast cement concrete 1:2:4 type B-1 (20mm graded aggregate ) as in manholes cover slab etc complete all as specified and directed by Engr In charge/ GE.
M&L for framed work as in frames to manhole covers of angle or other section including hold fast conforming Fe-410-O complete all as specified and directed by Engr In charge/ GE.
M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed by Engr In charge/ GE.
All as per srl item No. 16 above but 5mm dia and over including 10mm dia in stirrups, spaces and binders etc complete all as specified and directed by Engr In charge/ GE.
M&L 200mm bore Reinforced concrete pipes,class NP2,laid and jointed complete with coller complete all as specified and directed by Engr In charge/ GE.
M&L for Plain cement conc 1:4:8 type D-2 using 40mm graded agg as in conc bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 200mm bore pipes all as specified.(Note- thickness of bed below the barrel of pipes 15 cm and width of bed : Outer diameter of drain pipes (not of sockets/collars) plus 30 cm complete all as specified and directed by Engr In charge/ GE.
M&L for 150mm bore salt glazed stone ware drain pipes laid in trenches and jointed complete all as specified and directed by Engr In charge/ GE.
M&L for Plain cement conc 1:4:8 type D-2 using 40mm graded agg as in conc bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 150mm bore pipes complete all as specified and directed by Engr In charge/ GE.
M&L for RCC M-25 (Nominal Mix, type B1 1:2:4) using 20mm graded stone aggregate as slabs supported on walls, beams and columns in floor, roofs, landing, balconies, canopies, deck slabs and in shelves and the like etc. including necessary form work complete all as specified and directed by Engr In charge/ GE.
S&F PVC (SWR) pipes 110 mm dia single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed by Engr In charge/ GE.
S&F PVC (SWR) branch pieces single (single Y) equal or inequal for 110 mm bore pipe
S&F PVC (SWR) branch pieces single (single Y) equal or inequal for 75 mm bore pipe
S&F PVC (SWR) junction single (single T) equal or inequal for 100 mm bore pipe
S&F PVC (SWR) junction single (single T) equal or inequal for 75 mm bore pipe
S&F PVC (SWR) reducers for 100 mm bore pipe
Extra over rendering or plastering for work in isolated widths or in widths not forming part of general plastering such as in bands, sunk panels, cornices, skirtings, drip moulds and similar work exc 15 cm but n exc 40 cm in width or girth; including cutting to edges, all mitres and stopped ends, etc., complete all as specified and directed by Engr In charge/ GE.
Taking down carefully, copper/ aluminum point wiring (light, fan, socket or power) complete including fitting such as switch, sockets, ceiling rose, pendants socket,fan regulators any type, rectangular board ,light fittings,terminal boxes etc removing materials for taking credit and making good disturbed surfaces of walls floors and ceiling complete complete all as specified and directed by Engr In charge/ GE.
Taking down carefully copper/aluminium sub main wiring of size 2.5/4/6 sqmm from surface/concealed at any height and removing the materials from site and making good the disturbed surfaces of walls,floors roofs etc complete all as specified and directed by Engr In charge/ GE.
Taking down Old/ Unserviceable MCB DBs TPN / Main Switches by disconnection of electric connection including old unsv MCCBs,MCBs, isolators etc and making good to distrubed surface complete all as specified and directed by Engr In charge/ GE.
Disconnecting and taking down un serviceable light fittings of any description/ capacity complete all as specified and directed by Engr In charge/ GE.
Point wiring for one light/ fan/bell point controlled by one switch using 1.5 Sq mm FRLSH copper conductor cables (multistanded) PVC insulated and unseathed in and including PVC concealed conduit as per site requirement (size not less than 20mm dia), medium grade with Modular sunken boxes & PVC/Metal back plate for mounting modular type switches, sockets & regulators etc with cover plate modular type including supplying and laying PVC insulated and stranded unsheathed 1100 volts coppper conductor cable 1.5 Sq mm as earth wire connected to earth dolly including cutting of chases in wall / ceiling etc and making good the disturbed surfaces match to existing with cement mortar and putty white/ colour wash complete all as directed. Make : Havells/ Finolex/ Polycab.
All as per item no 148 above but cable 2.5 sqmm FRLSH for one 3/5 pin 6 Amp socket outlet point on an independent board, complete all as specified and directed by Engr In charge/ GE.
All as per item no148 above but cable 2.5 sqmm FRLSH for one 3/5 pin 6 Amp socket outlet point on the same board with other switch, complete all as specified and directed by Engr In charge/ GE.
All as per Srl item No 148 but for 3 Pin 16 Amps socket outlet independent board with cable 2.5 Sq mm including copper PVC insulated PVC unsheathed 2.5 sq mm earth wire standard and connected to earth dolly, complete all as specified and directed by Engr In charge/ GE.
All as per Item No.148 But for one light point control by two nos two way switches with other Independent Board with 1.5 sqmm PVC insulated unsheathed FRLSH copper conductor single core multi strand flexible cable and 1.5 sqmm PVC insulated unsheathed FRLSH copper conductor as earth lead complete all as specified and directed by Engr In charge/ GE.
S&F for modular switch 10 Amps single pole two way 230 V, 50 Hz, AC , with inner / outer cover required module complete all as specified and directed by Engr In charge/ GE. Make- Havells crabtree/ Legrand/ L&T
S&F for modular switch 6 Amps single pole one way 230 V, 50 Hz, AC , with inner and outer cover strip required module complete all as specified and directed by Engr In charge/ GE. Make- Havells crabtree/ Legrand/ L&T
S&F for modular switch 16 Amps single pole one way 230 V, 50 Hz, AC , with inner and outer cover strip required module complete all as specified and directed by Engr In charge/ GE. Make- Havells crabtree/ Legrand/ L&T
S & F modular Bell push flush type 6 amp 230 V, 50 Hz, AC , with inner and outer cover strip required module complete all as specified and directed by Engr In charge/ GE. Make- Havells crabtree/ Legrand/ L&T
S&F for modular socket 3 Pin 6 Amps flush type 230 V, 50 Hz, AC , with inner and outer cover strip required module complete all as specified and directed by Engr In charge/ GE. Make- Havells crabtree/ Legrand/ L&T
S&F for modular socket combined 2-in-1, 6 Pin 6 & 16 Amps 230 V, 50 Hz, AC , flush type with inner and outer cover strip required module complete all as specified and directed by Engr In charge/ GE. Make- Havells crabtree/ Legrand/ L&T
S&F electronic step type fan regulator 100 watt 230 volts 50Hz two module C/S deluxe type complete all as specified and directed. Make- Havells crabtree/ Legrand/ L&T
M &L Ceiling rose, surface bakelite 65x 50mm two to three terminals fixed on PVC Round Block, complete all as specified and directed by Engr In charge/ GE. Make- Havells crabtree/ Legrand/ L&T
S & F calling Bell ding dong 230 volts single pole 50Hz complete all as specified and directed by Engr In charge/ GE.Make: Havells/ Legrand/ANCHOR ROMA
S&F Sheet metal enclosure double door type for DBs (when MCB to be used) 12 way 240 volts with 200 Amps rated busbar and neutral link including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed by Engr In charge/ GE. Make:- Havells/ legrand/ Schneider.
S & F in replacement MCB single pole 240 volt any rating from 10 to 32 amps "C" series, with rupturing capacity 10 KA ,inculding providing thimble for out going cable, complete all as specified and directed by Engr In charge/ GE. Make:- Havells/ legrand/ Schneider.
S & F in replacement MCB single pole and neutral 240 volt any rating from 63 Amps "C" series, with rupturing capacity 10 KA ,inculding providing thimble for out going cable, complete all as specified and directed by Engr In charge/ GE. Make:- Havells/ legrand/ Schneider.
S&F Sub main wiring with two single core PVC insulated with copper conductor cable stranded of size 6 Sqmm in PVC concealed conduit 25mm dia including PVC insulated copper conductor cable 6 Sq mm as earth lead all as specified. Including taking down old sub main wire,complete all as specified and directed by Engr In charge/ GE. Make: Gloster/ Finolex/ Polycab.
S&F Sub main wiring with two single core PVC insulated with copper conductor cable stranded of size 4 Sqmm in PVC concealed conduit 25mm dia including PVC insulated copper conductor cable 4 Sq mm as earth lead Including taking down old sub main wire, complete all as specified and directed by Engr In charge/ GE. Make: Gloster/ Finolex/ Polycab.
Earthing complete with galvanized steel earth plate electrodes 600 mmx600 mm x6.3 mm thick buried directly in ground earth plate not less than 2.25 m deep below normal ground level with top edge of the plate not less than 1.5 m below normal ground level connected to and including galvanized steel earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron and steel including PCC pit in PCC 1:2:4 type B-1using 20 mm graded crushed stone aggregate, RCC frame with 40mm thick RCC cover reinforced with 8mm dia deformed bars handle. including excavation and earth work in any type of soil medium grade GI watering pipe 20mm bore with funnel and wire mesh and light grade GI protection pipe 15mm bore main board complete all as shown in electrical plate No 5 connected to main control board all as specified and testing on completion. Note: Excavation earthwork charcoal PCC pit is covered under this item including taking out existing earth plate etc.Note: if earth resistance of earthing is not found (2 to 5 Ω) satisfactory if will be redone by the contractor on his risk and cost, complete all as specified and directed by Engr In charge/ GE.
Taking down ceiling fan/Exhaust fans (C/F of any size/make), cleaning its dust particles oiling,greasing,one coat of synthetic enamel white spray painting with blade ,reassemble the same along with all fittings and hanging the same back to its original position including connecting the wire to ceiling rose etc complete after completing the wiring complete all as specified and directed by Engr In charge/ GE. Note :- (i) The spares like condensor, ball bearing, cotter pin, nuts & bolts, connecting rods & hooks etc if found defective/damage deemed to be replaced and make the ceiling fans functional. No extra payments will be done on this account.
S & F Angular Lamp holder, PVC/Polycarbonate type with cord grip cap suitable for light fittings, complete all as specified and directed by Engr In charge/ GE.
Supply and fixing LEDBulb 15W, 230V,AC suitable for Angular Lamp holder complete all as specified and directed by Engr In charge/ GE. Make :- Wipro/Havells/C&S/Polycab
Supply and fixing replacement LED lights fitting 1x 20W, 230V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engr In charge/ GE. . Make :- Wipro/Havells/C&S/Polycab
S & F replacement LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitablesize, complete all as specified and directed by Engr In charge/ GE. Make :- Wipro/Havells/C&S/Polycab
Supply and fixing replacement LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engr In charge/ GE. Make :- Wipro/Havells/C&S/Polycab
Supply and fixing replacement LED building security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp,clamps,suitable bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engr In charge/ GE. Make :- Wipro/Havells/C&S/Polycab
S&F Street light Bracket complete made of GI pipe of suitable size, medium grade 1.2 m long bent to shape as per site requirement along with MS flat iron clamps with nuts, bolts, washers including grouting the same with wall , complete all as specified and directed by Engr In charge/ GE.
Material & Laying in trenches or passing through pipe, 1100 volts grade heavy duty cable with "XLPE" insulated aluminium conductor standard served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed of 25 Sqmm x 3.5 core size all as specified including taking down old cable, complete all as specified and directed by Engr In charge/ GE. Note : Earth work and other connected work shall be measured & paid sperately.
Excavation in trenches and exceeding 1.5m wide and not exc 1.5m in depth in hard and dence soil and getting out complete all as specified and directed by Engr In charge/ GE.
Returing, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed by Engr In charge/ GE.
Removing excavated material (soil) to a distance not exc 50m and depositing where directed at a level not exc 1.5 m above the starting point complete complete all as specified and directed by Engr In charge/ GE.
M & L Dry sand for sand cushioning to under ground cable 8 cms thick before laying the cable before and 15 cms thick after laying & streching the cable in trenches, including hand punning and consolidating complete all as specified and directed by Engr In charge/ GE. Note : for payment purpose punned thickness shall be measured
M&L Bricks sub class 'B' brick laid dry, flat with width equal to length of brick as cover laid over the cabel to give mechanical protection to underground cabels all as specified.
Supply and fixing in repairs GI tubing light grade 40 mm dia along the wall/ in trenches/ in duct / in culvert /road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holdining of GI pipe alongwith poles complete all as specified and directed by Engr In charge/ GE.
S&F for modular TV socket outlet single with inner and outer cover strip required module including TV cable required length from roof complete all as specified and directed by Engr In charge/ GE. Make: Havells/ Legrand/ANCHOR ROMA
Removing and refixing water heater,25 ltr capacity 220V,AC single phase including nut bolt, copper conductor cable of suitable size , one coat of synthetic enamel white spray painting complete all as specified and directed by Engr In charge/ GE.
Supply and fix ceiling fan, AC single Phase. 230V of size 1200mm sweep with, blades, and frame along with all electrical wire connection complete all as specified and directed by Engr In charge/ GE.
M/s AKHIL SHARMA (BID ID -3271349)
VIRINDER SINGH (BID ID -3270512)
s l sharma and sons (BID ID -3271404)
joginder singh and sons (BID ID -3275702)
anil construction co. (BID ID -3269286)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .