Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 CrAdmitted-Finance 6 VANARAI SHOPPING COMPLEX W E HIGHWAY GOREGAON E MUMBAI 400065 | MUMBAI SUBURBAN | MAHARASHTRA | 400065 | ₹1.6 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.7 Cr+₹17.1 L (10.9%)Admitted-Finance 801 VENUS BENECIA PAKVAN DINING LANE OPP RAJPATH CLUB S G HIGHWAY BODAKDEV AHMEDABAD 380053 | AHMADABAD | GUJARAT | 380053 | ₹1.7 Cr+₹17.1 L (10.9%) | L2 | Admitted-Finance |
| 3 | L3₹1.8 Cr+₹22.3 L (14.3%)Admitted-Finance 1 GANESH DARSHAN ADV SURVE MARG SANDHURST ROAD W MUMBAI 9 | MUMBAI | MAHARASHTRA | ₹1.8 Cr+₹22.3 L (14.3%) | L3 | Admitted-Finance |
| 4 | L4₹2.1 Cr+₹49.3 L (31.5%)Admitted-Finance FIRST FLOOR BELLA VISTA OSWAL PARK POKHRAN ROAD NO 2 THANE W MUMBAI 400601 THANE MAHARASHTRA 400601 | THANE | MAHARASHTRA | 400601 | ₹2.1 Cr+₹49.3 L (31.5%) | L4 | Admitted-Finance |
| 5 | Rejected-Technical H NO 384 EKTA ENCLAVE HOTEL SAHARA RESIDENCY BUILDING NAVPUR NAKA ROAD BOISAR WEST THANE MAHARASHTRA 401501 | PALGHAR | MAHARASHTRA | 401501 | - | - | Rejected-Technical As per tender document,electrical contractor license was need to be submitted.Due to non-submission of the same by bidder,Therefore bidder is rejected. |
| Sl No | Description | Qty | Unit | SARASWAT ENGINEERING SERVICES L1 | SPEEDFROST SERVICES PVT LTD L3 | JBS ENTERPRISES PVT LTD L4 | ABHISHEK INTEGRATIONS LIMITED L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Preventive and Breakdown maintenance of various elctrical systems installed at INRP site,Project and design office. | 687 | Task | 16,662 ₹1,14,46,794 | 15,905 ₹1,09,26,735 Lowest | 16,100 ₹1,10,60,700 | 17,450 ₹1,19,88,150 |
| 2.00Complete servicing of 6.6KV feeder panel including VCB by OEM/authorized representative of OEM and as per technical specification. | |||||||
| 2.10 | 2500 A | 8 | Set | 7,952 ₹63,616 Lowest | 19,470 ₹1,55,760 | 19,575 ₹1,56,600 | 14,160 ₹1,13,280 |
| 2.20 | 1250 A | 4 | Set | 7,952 ₹31,808 Lowest | 16,874 ₹67,496 | 19,575 ₹78,300 | 11,210 ₹44,840 |
| 2.30 | 630 A | 32 | Set | 7,952 ₹2,54,464 Lowest | 12,980 ₹4,15,360 | 15,777.5 ₹5,04,880 | 9,440 ₹3,02,080 |
| 3.00Complete servicing of 433V feeder panel including ACB by OEM/authorized representative of OEM and as per technical specification. | |||||||
| 3.10 | 4000 A | 4 | Set | 5,302 ₹21,208 | 9,086 ₹36,344 | 14,175 ₹56,700 | 4,720 ₹18,880 Lowest |
| 3.20 | 2500 A | 16 | Set | 5,302 ₹84,832 | 9,086 ₹1,45,376 | 14,175 ₹2,26,800 | 4,130 ₹66,080 Lowest |
| 3.30 | 1600 A | 48 | Set | 5,302 ₹2,54,496 | 9,086 ₹4,36,128 | 11,475 ₹5,50,800 | 3,540 ₹1,69,920 Lowest |
| 3.40 | 1250 A | 24 | Set | 5,302 ₹1,27,248 | 9,086 ₹2,18,064 | 11,500 ₹2,76,000 | 2,950 ₹70,800 Lowest |
Tender Value
₹1.8 Cr
EMD Value
₹3.6 L
Closing Date
13 Sept 2023, 3:00 pmClosed
Project Director INRPC
Project Director,INRPC,NRB,BARC,Tarapur-401502,Dist-Palghar,Maharashtra
Upkeeping of 33KV/433V Indoor,Outdoor substation equipments,street light fixtures and associated Electrical Equipments at INRP construction site,Tarapur
2023_NRB_766408_1
BARC(T)/NRB/INRPC/ELE-47/1213 dated 08/08/2023
Open Tender
Electrical Works
Item Rate
730 days
BARC Tarapur
Please refer tender document
8 documents required · 8 mandatory
₹0
₹3.6 L
PD office,INRP,BARC,Tarapur
29 Nov 2023
15 Aug 2023
14 Sept 2023
15 Aug 2023
13 Sept 2023
25 Aug 2023
15 Aug 2023 - 24 Aug 2023
25 Aug 2023
Amount
Preventive and Breakdown maintenance of various elctrical systems installed at INRP site,Project and design office.
Complete servicing of 6.6KV feeder panel including VCB by OEM/authorized representative of OEM and as per technical specification.
Complete servicing of 433V feeder panel including ACB by OEM/authorized representative of OEM and as per technical specification.
Supply and making of straight thropugh cable Jointing kit of heat shrinkable type of approved make suitable for cable of voltage grade 1100V suitable for cable of following size.
4C ×10 sqmm (cu)
Supply
Installation
3.5C ×300/400 sqmm (AL) as approved by Engineer-in-Charge
Supply
Installation
Labour work for Underground Cable fault detection with latest technology and making of straight through heat shrinkable type cable joint for 33KV/6.6 KV HT underground cables of size 3C × 400 sqmm(Al).
Labour work for Underground Cable fault detection with latest technology and making of straight through heat shrinkable type cable joint for 1.1KV grade underground cables of size range as mentioned below.
3.5C ×35 sqmm (Cu) to 3.5C ×185 Sq. mm(Al/Cu)
3.5C×300/400 sqmm (AL)
Complete external Painting of transformer as per the attached technical specification.
Excavation in all type of soils of width as specified in the technicals specification as per the size and the no of runs and a depth of 1000mm below ground level, sand bedding, laying of baked brickews on side and top, back billi ng,dewatering, consolidation shoring, disposal of excess earth, Item includes supply of river sand and class- 1 bricks.
Supply of 70W,IP 66, Street Light LED fixture of lumen output greater than 7000 lm and as per technical specification.
Supply
Installation
Master LED tube 1200mm, 18W,CCT of 6500K and as per technical specification.
Supply
Installation
Outdoor type 24FOC Joint Kit suitable for splicing and fixing of 24 cores of FOC
Supply
Installation
70Watt LED integral driver flood light (wall mounted type) with cool white colour temperature of CRI>70. The luminaire shall meet IP66 rating with THD<15% & pf >0.9.The Luminaire housing should be made of pressure die cast aluminium.
supply
Installation
Electrical Gloves for work safely at High voltages.
Class 4(≤36000 V AC) HT Electrical gloves comply with ASTM standard and EN 60903
class 0 (≤1000 V AC)Electrical gloves comply with ASTM styandard and EN 60903
Providing and fixing Insulation Resistance Tester having rating 0.01MΩ to 10GΩ or above, Test voltages should be 1000V,complies with IEC/EN 61010-1 2nd Edition for measurement category IV 600 V (CAT IV) with IP40 or above rating.
Providing and fixing High Temperature Infrared Thermometer having range atleast -30°C to 900°C,ultra-high 60:1 distance-to-spot ratio aslo include features of technical specification.
Providing and fixing Tong Clamp Tester With features of AC current measurements up to 400 A,CAT IV 300 V/CAT III 600 V safety rating, Resistance range of 40 k,Screen Refresh Rate : >2 Times / Sec
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
Making the opening in brick masonry for door / window / clear story opening including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete to match existing surface including disposal of mulba/ rubbish to the nearest dumping ground.
ABHISHEK INTEGRATIONS LIMITED
SPEEDFROST SERVICES PVT LTD
JBS ENTERPRISES PVT LTD
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 4.19 MB
BOQ_805635.xls
BOQ • 0.30 MB
TechnicalBid.xls
Tender Documents • 0.18 MB
Tenderdoc.pdf
Tender Documents • 8.16 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .