Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.5 LAccepted-AOC | L1 | Accepted-AOC BEING L1 BIDDER | |
| 2 | L2₹32.7 L+₹3.0 L (10.0%)Rejected-Finance | L2 | Rejected-Finance Other than L1 BIDDER | |
| 3 | L3₹33.3 L+₹3.6 L (12.0%)Rejected-Finance OLD HASIMARA PO HASIMARA DISTT ALIIPURDUAR WB PIN 735215 | HASIMARA | ALIPURDUAR | WEST BENGAL | 735215 | L3 | Rejected-Finance Other than L1 BIDDER | |
| 4 | L4₹34.1 L+₹4.5 L (15.0%)Rejected-Finance 21 JHAMRI 151 JHAMRI JHAMRI ROHTAK HARYANA 124142 UDYAM HR 07 0030314 | JHAJJAR | HARYANA | 124142 | L4 | Rejected-Finance Other than L1 BIDDER | |
| 5 | L5₹34.7 L+₹5.0 L (17.0%)Rejected-Finance | L5 | Rejected-Finance Other than L1 BIDDER |
Tender Value
₹28.5 L
EMD Value
₹57,000
Closing Date
1 Jul 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) HASIMARA
GE (AF) HASIMARA, PO-HASIMARA, DIST- ALIPURDUAR, PIN-735215
PROVN OF ALUMINUM PARTITION KITCHEN CABINET AND MISC WORKS, REPAIR/MAINT OF COOLIG APPLIANCE AND ADDN/ALTN TO LT UG XLPE CABLES AND ALLIED WORKS AT 652 COY ASC (CIV GT) IMTRAT UNDER GE (AF) HASIMARA
2025_MES_712069_1
C/8883/2025-26/E8
Open Tender
Civil Works
Item Rate
210 days
GE (AF) HASIMARA
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (AF) HASIMARA
₹57,000
Yes
5 Aug 2025
3 Jun 2025
3 Jul 2025
3 Jun 2025
1 Jul 2025
17 Jun 2025
Amount
S&F powder coated aluminium frame (minimum thickness of powder coating 50 micron) for doors, windows / ventilators and partitions etc., with one or more rebates including joining cleat for fixing etc., complete all as directed and specified.
S&F powder coated anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber, neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc., complete all as directed and specified. (Note:- Glass/ other filling material in panels shall be measured and paid separately)
S&F 12mm thick prelaminated particle board, interior grade, prelaminated both side with decorative choice lamination fixed with aluminium frame partition or aluminium door, complete all as specified and directed.
S&F 18mm thick prelim wooden finished PVC plastic celluka ply for cupboard, shelf etc including all required joining accessory, complete all as specified and directed.
S&F 40mm dia, cupboard knobs fixed with nut, screw and washer of brass polished, complete all as specified and directed.
S&F stainless steel concealed hinges of any colour with fixing arrangement, complete all as specified and directed.
S&F continuous (piano) hinges, mild steel, bright finish or electrogalvanized width of flap (whwn open) 30mm, complete all as specified and directed.
S&F ball catches with 8mm dia steel ball, and brass body and striking plate including letting in and fixed, complete al as specified and directed.
S&F plain sheet glass 4.8mm thick, of any colour and glazing with and including anodised aluminium snap beading or rubber/reopen bead, fixed in aluminium frame or door frame, complete all as directed and specified.
S&F 3 to 5mm thick ACP sheet in panels of aluminium partition, aluminium door exc. 0.5 Sqm in each pane with rubber beading, complete all as directed and specified.
S&F floor door stopper, 150mm long of aluminiurn alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, complete all as specified and directed.
S&F 200mm long aluminium anodised tower bolt of extruded section, complete all as directed and specified.
M&L for 4mm thick pre-painted E-fibre board, designer/decorative, fixed or laid/inserted to GI snap grid frame size 605x605 mm work for false ceiling hangers with 4mm to 6mm dia. G.I. (length as required) adjusting level, fixed to roof slabs/truss by means of ceilling cleats made out of G.I. flat 40 x 3mm size 60mm long and expansion hold fasteners, 12.5mm dia, 40mm long, complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backin), removing serviceable tiles to store and rubbish off the premises, complete as specified and directed.
M&L for glazed ceramic coloured tiles 7 to 8mm thick each area in vertical surface 350 x 250 x 7mm/450 x 300x 7mm thick set and jointed in neat cement slurry such as skirting dados and risers to steps etc, and pointed in white or colour cement to match over and including 10mm thick rendering in CM (1:4), complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement of match the surfaces over and including 15mm thick screed bed in CM (1:6), complete all as specified and directed.
Taking down and servicing of split type AC of 1.5 to 2 TR capacity, any type/size/make/model cleaning and washing of condenser assembly with chemical and high pressure jet pump, checking and retightening of all electrical connections, replacement of nuts, bolts, screws, washers, internal wiring and refixing properly after servicing, complete all as specified and directed. Note : (i) Spare parts & gas charging shall be measured & paid seperately under respective items.
Taking down and servicing of window type AC of 1.5 to 2 TR capacity, any type/size/make/model cleaning and washing of condenser assembly with chemical and high pressure jet pump, checking and retightening of all electrical connections, replacement of nuts, bolts, screws, washers, internal wiring and refixing properly after servicing, complete all as specified and directed. Note : (i) Spare parts & gas charging shall be measured & paid seperately under respective items.
Taking down and servicing of refrigerators of 165 Ltr to 320 Ltr capacity, any type/size/make/model including replacement of unserviceable parts and cleaning, washing, condenser assembly, retighening all electrical connections, replacement of nuts, bolts, screw, washers, internal wiring, fixing properly bracket housing of capacitors and reassembling properly after repair, complete all as specified and directed. Note : (i) Spare parts & gas charging shall be measured & paid seperately under respective items.
M&L for testing leakage of gas and replacement of damaged portion of copper pipe of any dia upto 30cm length, brazing by oxyaccetelene gas welding and good quality copper brazing rods or soldering damaged portion, flaring copper pipe, replacement of flare nut and pouring the nitrogen gas flushing to check the leakage in copper pipe lines, recharging suitable gas fully after complete removal of nitrogen gas on satisfactorily completion of leak test, reassembling and testing cooling of whole refrigerator of any capacity/type and make, complete all as specified and directed.
All as per item No 21.00 here-in-before but for window type AC with R-22 gas, of any capacity/make/type/model, complete all as specified and directed.
All as per item No 21.00 here-in-before but for water cooler with R-134 gas, of any capacity/make/type/model, complete all as specified and directed.
All as per item No 21.00 here-in-before but for split type AC with R-22/134/410A gas, of any capacity/make/type/mode/model, complete all as specified and directed.
Dismantling and taking down from existing position split type AC of capacity 1.5/2 ton and refixing the same in new position including necessary cutting opening, fixing, connecting, testing and making good disturbed surface of old position and new position etc, complete all as specified and directed. Note : Necessary gas charging, mounting stand, drain pipe and copper tube shall be paid and measured seperately.
Taking down and dismantling the unserviceable blower motor from 1.5/2 TR window/split AC of any type including opening all outer case and rewinding,heat varnishing the blower motor with super enamel copper wire of suitable gauge by taking out burnt winding and cleaning the iron core, complete all as specified and directed.
All as per item No 26.00 here-in-before but blower motor of water cooler of capacity 40 to 80 Ltr, complete all as specified and directed.
S & F in replacement of door gasket suitable for deep freezer 300/320 ltr & 310/286/165 lty capacity refrigator, complete all as specified and directed.
S & F in replacement of freezer including necessary capilary suitable for 165 lty capacity refrigator, complete all as specified and directed.
S & F in repair cooling coil assy suitable for 180 to 310 Ltr capacity refrigerator, complete all as specified and directed.
S & F fan motor, single phase 230 Volt, 50 Hz suitable for window AC, complete all as specified and directed.
S & F in repair harmetic sealed type compressor suitable for window AC of capacity 1.5 TR, complete all as specified and directed.
S & F in repair rotary compressor of 1.5/2 ton capacity suitable for split type AC of any make/model 1.5 TR capacity, complete all as specified and directed.
S & F in repair outdoor fan motor, single phase 230 Volt, 50 Hz suitable for split AC 1.5/2.0 TR capacity, complete all as specified and directed.
S & F in repair strainer of condenser coil set suitable for windoe type AC of 1.5 ton capacity, complete all as specified and directed.
S & F of swing motor fot split AC fited in internal unit capacity 3 to 5 watt, 5 to 8 RPM suitable for 1.5/2.0 TR capacity with wiring kit and thimble, complete all as specified and directed.
S & F in replacement of air filter for split AC as per sample suitable for 2.0 ton capacity, complete all as specified and directed.
S & F in repair multi terminal capacitor (50 + 6/50 + 4mfd) suitable for split AC (stating, running and fan combined), complete all as specified and directed.
S & F in repair 15mm dia PVC drain pipe, medium grade, for split AC as per existing, complete all as specified and directed.
S & F in repair PCB for outdoor unit of invertor AC model and make as per existing, complete all as specified and directed.
S & F in repair PCB for indoor unit of invertor AC model and make as per existing, complete all as specified and directed.
Supply and filling of refrigerant gas R-22/32 in factory sealed cylinder, complete all as specified and directed.
Supply and filling of refrigerant gas R-134a factory sealed cylinder, complete all as specified and directed.
Supply and filling of refrigerant gas R-410A factory sealed cylinder, complete all as specified and directed.
S & F in repair blower motor, Indoor unit, single phase 230 V suitable for window type AC 1.5/2 ton, complete all as specified and directed.
S & F in repair in repair copper tube 1/4", complete all as specified and directed.
S & F in repair in repair copper tube 1/2", complete all as specified and directed.
S & F in repair in repair insulation tube 1/4", complete all as specified and directed.
S & F in repair in repair insulation tube 1/2", complete all as specified and directed.
S & F in repair in repair copper tube 5/8", complete all as specified and directed.
S & F in repair in repair insulation tube 5/8", complete all as specified and directed.
S & F in repair harmetic sealed compressor suitable for cooling capacity 40/80Ltr water cooler, complete all as specified and directed.
S & F in repair condensor unit assembly suitable for split AC 1.5 /2 ton capacity, complete all as specified and directed.
S & F in repair split AC outdoor mounting stand as per existing, complete all as specified and directed.
Supply and installation 10 Mtr hot dip galvanised octagonal poles with 155mm bottom & 70mm top A/F made up of 3mm thick HT sheet alongwith base plate of size 250 x 250 x 16mm (Door with Hinge) with 4 Nos of M24 x 750mm high 'J' type EN 8 grade Including foundation of PCC (1:3:6), & bolts along with template, complete all as specified and directed.
Supply and fixing of 1.5m long Hot dip galvanised single arm bracket made up of 40 NB dia GI pipe suitable to mount on pole having top 70 mm A/F, complete all as specified and directed.
M&L for PCC (1:3:6) type C1 (using 20mm graded crushed stone aggregate) as in pole pedestal (PCC) including necessary formwork, complete all as specified and directed.
Supply and fixing LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, complete all as specified and directed.
S & F junction box made from SMC/FRP sheet ready made size of junction box 295x195x100mm with aluminium bus bar of 50 Amp capacity for RYB and half for neutral made in suitable size fixed inside the junction box with necessary supporting insulators fixed on hylem sheet, MS sheet steel fixed inside the bottom portion of box to connect the cable gland complete , entire assembly fixed to pole /Wall with MS clamp 25 X 5 mm and nuts & bolts, including MCB SP 6 Amp 10 KA 240 V - 1 No, with necessary size copper lugs for connecting cables from junction box to fittings, complete all as specified and directed.
Supplying, installing, testing and commissioning of outdoor type LT feeder piller box made out of 3.0mm thick CRCA sheet out door type, CPRI approved ,totally enclosed weather dust and vermin proof as per IS with front and rear 400 Amp capacity for RYB and half for neutral and insulated with insulators, including connecting incoming and outgoing cables necessary made out of 50 x 50 x 6mm angle iron grouted at floor above 30cm from ground level including PCC, (1:3:6) in foundation comprising the following including taking down old unserviceble LT feeder piller box, complete all as specified and directed. Incoming :- (i) MCCB of 4 pole of capacity 200 Amps with breaking capacity of 36 KA-01 No. Outgoing :- (i) MCCB of 4 pole of capacity 100 Amps with breaking capacity of 16 KA -03 Nos (ii) MCB of 4 pole of capacity 32 Amps with breaking capacity of 10 KA -02 Nos Note:Cost of internal wiring of meters, indication lamps, CTs, etc and rigid bus bar connections from bus bar to MCCB terminals connection, bus bar to MCCB/MCB connections shall deemed to be included in the unit quoted rate.
Supply and fix in replacement for electronic Timer for 24 hrs , top mounting for all contactors (frame 1 to 4) suitable for street light, complete all as specified and directed.
S&F in repair GI bracket fixing to street light poles, made out of 50mm bore GI pipe, medium grade, bend to shape including applying two coats of aluminium paint over a coat of red oxide primer, complete all as specified and directed.
S & F in replacement 3 core PVC insulated sheathed multistranded copper conductor cable of size 2.5 Sqmm passing through PVC conduit from junction box to fittings, complete all as specified and directed. (Note: PVC conduit shall be measured and paid seperately.)
S & F rigid 20mm dia PVC non metalic conduit heavy duty, fixed on pole with necessary bend elbow, couplers, check nuts, FI clamp 40 x 4mm poles and nuts & bolts, PVC flexible conduit, connected to junction box to fitting etc, complete all as specified and directed.
S & F ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 200 Amps with barrier, handle and door locking kit system and necessary connection between two power sources as per site requirement, complete all as specified and directed.
M&L for painting existing steel tubular poles, 8.5 meter in height above GL, including cross arms and bracings, on existing surface after cleaning and removing dust, rust & dirt, applying one coat of red oxide primer and and two coat of synthetic enamel paint (1st grade quality) of required colour shade, as directed by Engr-in Charge, from ground level & upto 1.5 mtr and two coats of aluminium paint paint or rest of pole, externally, including numbering of pole, complete all as specified and as directed.
S&F in replacement LED bollard light 10 watt with soft 360 degree light distribution, IP-65, inverted pyramid tripod type with PCC & fixing all arrangemnts, complete all as specified and directed.
S&F in repair MCCB 160 Amps AC 3 pole 415 Volt 36 KA breaking capacity as per IS/IEC 60947-2 with thermal magnetic release including providing new thimble / lugs of suitable size and taking down old unserviceable one, complete all as specified and directed.
S&F in repair MCCB 200 Amps AC 4 pole 415 Volt 36 KA breaking capacity as per IS/IEC 60947-2 with thermal magnetic release including providing new thimble / lugs of suitable size and taking down old unserviceable one, complete all as specified and directed.
S&F in repair MCCB 200 Amps AC 4 pole 415 Volt 50 KA breaking capacity as per IS/IEC 60947-2 with thermal magnetic release including providing new thimble / lugs of suitable size and taking down old unserviceable one, complete all as specified and directed.
S&F in repair MCCB 100 Amps AC 4 pole 415 Volt 25 KA breaking capacity as per IS/IEC 60947-2 with thermal magnetic release including providing new thimble / lugs of suitable size and taking down old unserviceable one, complete all as specified and directed.
S&F in repair MCCB 250 Amps AC 4 pole 415 Volt 25 KA breaking capacity as per IS/IEC 60947-2 with thermal magnetic release including providing new thimble / lugs of suitable size and taking down old unserviceable one, complete all as specified and directed.
S&F in repair MCCB 400 Amps AC 4 pole 415 Volt 36 KA breaking capacity as per IS/IEC 60947-2 with thermal magnetic release including providing new thimble / lugs of suitable size and taking down old unserviceable one, complete all as specified and directed.
Excavation in trenches not exceeding 1.5 metre wide and not exc 1.5 metre in depth for foundation of pole, or cable trenches etc. n. exc. 10 Sqm on plan and getting out in soft/loose soil, complete all as specified and directed.
Supply only screw driver tool kit, battery powered, with dual mode and LED working light (fwd - reverse button), 3.7 volt for power house emergency use, containing following tools :- (i) 1-1/8" bits - 46 Nos, (ii) 1-3/4" bits-6 Nos, (iii) Sockets -06 Nos, (iv) Magnetizer -01 No, (v) Triangular Tablet -01 No, (vi) Screw Storage Box -01 No, (vii) Flexible Extension Bar -01 No, (vii) Metal Crowbar -01 No, (viii) Cleaning Brush -01 No, (ix) Magnetic Extension Bar -01 No, (x) Plastic Crowbar -01 No, (xi) Screwdriver Handle -01 No, (xii) Straight Tweezer -01 No, (xiii) Curved Tweeze -01 No, (xiv) Thimble & Mini Suction Cup-01 No.
Returning filling in incl spreading, leveling watering and well ramming in layers not exceeding 25cm in soft/loose soil, complete all as specified and directed.
Removing of excavated materials to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point in any type of soil, complete all as specified and directed.
Supply, filling in trenches, spreading, leveling sand cushioning 8cm below cable and 15cm above the cable punned down to 18cm for under ground cable, complete all as specified and directed. (Note : Punned thickness shall be measured for payment)
Supply and laying well burnt sub class 'B' bricks, old size, laid in trenches perpendicular to UG cable above sand cushioning for cable protection, complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 Sqmm 3.5 core including taking down old unserviceable UG cable, complete all as specified and directed.
All as per item No 81.00 here-in before but size 150 Sqmm 4 core, complete all as specified and as directed.
All as per item No 81.00 here-in before but size 50 Sqmm 3.5 core, complete all as specified and as directed.
Note: An amount of Rs.23,075.00 on account of Credit Schedule for schedule 'A' part - II shall be deducted from the total amount of BOQ to arrive at the contract sum.
CONSTRUCTION SHELTER (BID ID -3338554)
M/S BIJAY KUMAR SHIVA (BID ID -3338582)
M/S. KUMAR CONSTRUCTION CO. (BID ID -3340853)
SHRI D P AGARWAL (BID ID -3337273)
M/S. NARENDRA KUMAR GARG (BID ID -3338585)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .