CSD OFFICE RRCAT INDORE
Supply, installation, testing and commissioning (SITC) of 150 Tonnage capacity (minimum) Air Cooled Chiller with adiabatic cooling kit against buyback of 150 tonnage capacity Air Cooled Chiller at RRCAT, Indore.
2026_RRCAT_918998_1
RRCAT/CSD/EEACS/2026/W-4412
Open Tender
Miscellaneous Works
Item Rate
180 days
RRCAT
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹1.6 L
24 Jul 2026
24 Jul 2026
21 Aug 2026
24 Jul 2026
18 Aug 2026
10 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply, installation, testing and commissioning (SITC) of 150 Tonnage capacity (minimum at 45 degC) Air Cooled Chiller with adiabatic cooling kit against buyback of 150 tonnage capacity Air Cooled Chiller (Make Blue Star, Model no. LCAX2-1055D) as per technical specification. | |||||
| 1.01 | Supply, Installation,Testing and Commissioningof Eurovent/AHRI certified Aircooled chiller as per tender specification of 150 TR actual capacity at 45 degC ambient temperature (without adiabatic kit) and operating conditions as given below with screw compressors with VFD and single refrigerant circuits operating on refrigerant R-134a/equivalent or better driven by suitable motor, air-cooled condenser copper tubes & fins with anti corrosion coating, flooded/DX type shell & tube evaporator,VFD on condenser fans, flow switches at chiller inlet/outlet, initial refrigerant & oil charged from the factory, microprocessor based control panel, spring isolators of suitable capacity all mounted on M.S. frame.Chiller shall be BMS compatible with its control panel having BACnet/Modbus/IP based network platform with ethernet/RS-485 port for compatible with existing PLC based system. The motor shall be with class 'F' Insulation suitable for 415 volts ±10%, 50Hz± 5 %, three phase AC supply. Factory testing of the chiller at AHRI approved test bed. | 1 | No. | - | - |
| 1.02 | Site Operating Parameters | - | - | - | - |
| 1.03 | Air Entering Temp. to the Condenser: 45ºC | - | - | - | - |
| 1.04 | Chiller :- CHW in at 12 ºC & CHW Out at 7ºC | - | - | - | - |
| 1.05 | Chiller Fouling Factor - 0.0001 FPS | - | - | - | - |
| 1.06 | Chilled Water Flow: As per AHRI | - | - | - | - |
| 1.07 | Total Pr.Drop: < 7 Meters of water | - | - | - | - |
| 1.08 | C.O.P at AHRI condition (35degC): 3.1 minimum. (without adiabatic cooling kit) | - | - | - | - |
| 1.09 | IPLV (SI): 5 min. (without adiabatic cooling kit) | - | - | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.22 MB
NIT.pdf
Tender Documents • 1.20 MB
SGFNIT.pdf
Tender Documents • 1.84 MB
Specialconditions.pdf
Tender Documents • 0.50 MB
GTP.pdf
Tender Documents • 0.53 MB
TechnicalSpecification.pdf
Tender Documents • 0.63 MB
SCHA.pdf
Tender Documents • 0.55 MB
BOQ_965764.xls
BOQ • 0.28 MB
Preferedmake.pdf
Tender Documents • 0.54 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].