Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.1 CrAdmitted-Finance | ₹6.1 Cr | L1 | Admitted-Finance |
| 2 | L1₹6.1 CrAdmitted-Finance M 13 S S HARMU HOUSING COLONY PS ARGORA PO DORANDA RANCHI JHARKHAND 834002 | RANCHI | JHARKHAND | 834002 | ₹6.1 Cr | L1 | Admitted-Finance |
| 3 | L2₹6.1 CrSame as L1Admitted-Finance | ₹6.1 CrSame as L1 | L2 | Admitted-Finance |
| 4 | Rejected-Technical NOT SPECIFIED | - | - | Rejected-Technical Non Responsibe |
| Sl No | Description | Qty | Unit | M/S ASHOK MANDAL L2 | Acme Construction Company L1 | M/S MANOJ KUMAR PANDEY L1 |
|---|---|---|---|---|---|---|
| 1.00 | Excavation for roadway in soil using manual means including loading in truck for carrying of cut earth to embankment site with all lifts and lead upto1000 metres. | 74 | cum | 208.8 ₹15,451.2 | 208.8 ₹15,451.2 | 208 ₹15,392 Lowest |
| 2.00 | Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item-A)and disposal of excavated earth as obtained to a distance upto 50 M.including all lifts. Levelling,remaining foundation trenches, removing roots of trees, shrubs all complete as per approved design, building and direction of E/I .Extra for earthwork in hard soil as per specification and direction of E/I (Vide classification of soil item_B). | 625 | cum | 108.48 ₹67,800 | 108.48 ₹67,800 | 108 ₹67,500 Lowest |
| 3.00 | Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of
surplus excavated soils as directed, within a lead of 50 m. Hard rock (blasting prohibited) | 55 | cum | 844.25 ₹46,433.75 | 844.25 ₹46,433.75 | 844 ₹46,420 Lowest |
| 4.00 | Filling in foundation trenches and plinth in layers not exceeding 150mm. Thick well watered, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50 M and lift of 1.5M all complete as per building specification and direction of E/I (Mode of measurement compacted volume). | 699 | cum | 35.84 ₹25,052.16 | 35.84 ₹25,052.16 | 35 ₹24,465 Lowest |
| 5.00 | Filling in foundation trenches and plinth in layers not exceeding 150mm thick well watered, rammed, fully compacted and fine dressed with earth obtained after cutting within a lead of 50m and lift of 1.5m all complete as per building specification and direction of E/I (Mode of measurement compacted volume). Extra for each subswquent lead upto 25m beyond the initial lead of 50m (Maximum upto 150m lead by jead load) as per specification and direction of E/I. | 609 | cum | 92.23 ₹56,168.07 Lowest | 92.23 ₹56,168.07 Lowest | 100 ₹60,900 |
| 6.00 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. | 450 | cum | 1,036.45 ₹4,66,402.5 | 1,036.45 ₹4,66,402.5 | 1,036 ₹4,66,200 Lowest |
| 7.00 | Construction of embankment with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2. | 528 | cum | 189 ₹99,792 Lowest | 189 ₹99,792 Lowest | 190 ₹1,00,320 |
| 8.00 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. | 273 | cum | 1,189.8 ₹3,24,815.4 Lowest | 1,189.8 ₹3,24,815.4 Lowest | 1,190 ₹3,24,870 |
| 9.00 | Providing R.C.C.M-75 with nominal mix of (1:4:8) in foundation with approved quality of stone metal grade -III (50 mm to 25 mm), size clean coarse sand-----do-----. | 404 | cum | 3,222.83 ₹13,02,023.32 | 3,222.83 ₹13,02,023.32 | 3,222 ₹13,01,688 Lowest |
| 10.00 | Providing 25 mm, thick damp proof course with cement concrete M-150 with nominal mix of (1:2:4) with approved quality of stone chips of 20 mm to 6 mm size graded and clean coarse sand of P.M. 2.5 to 3 including screening, shuttering, and mixing cement concrete in mixer with 5% cico or any other approved water proofing compound and placing in position, striking, curing, taxes and royalty complete, as per building specification and direction of E/I. | 412 | sqm | 146.88 ₹60,514.56 | 146.88 ₹60,514.56 | 146 ₹60,152 Lowest |
Tender Value
₹6.7 Cr
EMD Value
₹6.8 L
Closing Date
22 Jan 2020, 11:00 amClosed
Nodal officer
e-Procurement Cell, JSBCCL, 3rd Floor, Dhurwa, Ranchi-834004, Jharkhand.
Construction of Base Kitchen and Distribution Center under Mukhyamantri Canteen Scheme in Ranchi District
2020_JSBCC_43984_1
JSBCCL/45/2019-20
Open Tender
Civil Works - Buildings
Item Rate
455 days
RANCHI
Please refer Tender documents.
4 documents required · 4 mandatory
₹10,000
JSBCCL
₹6.8 L
7 Jan 2021
10 Jan 2020
24 Jan 2020
10 Jan 2020
22 Jan 2020
11 Jan 2020
Amount
Excavation for roadway in soil using manual means including loading in truck for carrying of cut earth to embankment site with all lifts and lead upto1000 metres.
Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item-A)and disposal of excavated earth as obtained to a distance upto 50 M.including all lifts. Levelling,remaining foundation trenches, removing roots of trees, shrubs all complete as per approved design, building and direction of E/I .Extra for earthwork in hard soil as per specification and direction of E/I (Vide classification of soil item_B).
Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m. Hard rock (blasting prohibited)
Filling in foundation trenches and plinth in layers not exceeding 150mm. Thick well watered, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50 M and lift of 1.5M all complete as per building specification and direction of E/I (Mode of measurement compacted volume).
Filling in foundation trenches and plinth in layers not exceeding 150mm thick well watered, rammed, fully compacted and fine dressed with earth obtained after cutting within a lead of 50m and lift of 1.5m all complete as per building specification and direction of E/I (Mode of measurement compacted volume). Extra for each subswquent lead upto 25m beyond the initial lead of 50m (Maximum upto 150m lead by jead load) as per specification and direction of E/I.
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Construction of embankment with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2.
Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.
Providing R.C.C.M-75 with nominal mix of (1:4:8) in foundation with approved quality of stone metal grade -III (50 mm to 25 mm), size clean coarse sand-----do-----.
Providing 25 mm, thick damp proof course with cement concrete M-150 with nominal mix of (1:2:4) with approved quality of stone chips of 20 mm to 6 mm size graded and clean coarse sand of P.M. 2.5 to 3 including screening, shuttering, and mixing cement concrete in mixer with 5% cico or any other approved water proofing compound and placing in position, striking, curing, taxes and royalty complete, as per building specification and direction of E/I.
M 20 grade cement concrete
Providing R.C.C.M - 200 with nominal mix of (1:1.5:3) in foundation and plinth with approved quality of stone-----do-----.
Providing R.C.C. M - 200 with nominal mix of (1:1 1/2:3) in column with ------do------
Providing R.C.C. M-200 in band at plinth level with -----do--------
Providing R.C.C. M-200 with nominal mix of (1:1.5:3) in band at Lintel level with -----do----------
Providing R.C.C. M -200 with nominal of (1:1.5:3) in staircase with approved quality of stone -----do-----
Providing R.C.C. M - 200 with nominal mix of (1:1.5:3) in roof slab with -----do-----
Providing av 63 mm thick R.C.C. M - 200 with nominal mix of (1:1.5:3) chejja with approved quality of stone -----do-----
Reinforced cement concrete work in vertical and horizontal fins individually or forming box louvers, facias and eaves boards above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand (zone-III) : 3 graded stone aggregate 20mm nominal size).
Providing Tor steel reinforcement of 8mm. Dia rods as per approved design and drawing -do- -do- TMT Fe 500 (only valid for SAIL & TATA Steel, JSPL, E lectro Steel Ltd and Vizal Steel)
Providing designation 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9"X4.5"X3") in C.M (1:4) in foundation and plinth with approved quality of clean coarse sand of F.M 2 to 2.5 including providing 10 mm thick mortar joints, cost of sceening materials, rackingout joints to 15mm depth, curing, taxes and royalty all complete as per building specificcation and direction of E/I.
Providing designation 75 A brick work of 230 thick in C.M. (1:6) in super structure with approved quality of clean coarse sand of F.M 2 to 2.5 including providing 10 mm thick mortar joint , cost of screening materials, scaffolding raking out jointsto 15 mm depth curing, taxes and royalty all complete as per buiding spacification and direction of E/I.
Ground Floor:
Providing designation 112mm thick reinforced designation 100A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9"X4.5"X3") in C.M. (1:4) in superstructure with approved quality of clean coarse sand of F.M 2 to 2.5 including the cost of screening, carriage of materials, scaffolding, raking out joints to 15mm depth, curing, taxes and royality (but exclufing the cost of reinforcement) all complete as per building specification and direction of E/I.
KSRB 7.4: Providing and fixing 1mm thick M.S. door with frame and diagonal braces of size 40406 mm angle Iron, using M.S. flats 306mm for diagonal braces and central cross pieces 3.15mm thick M.S. Gusset plates at the junctions and corners, with handles, stoppers and locking arrangements etc., including applying a priming coat of red lead paint cost of matetrials, labour, HOM of machinery complete as per specifications. 1 double leaf door of size 2.42.4m Specification No.KBS 7.9/7.12
Supplying, fitting and fixing good quality, well dressed and well seasoned sal wood work in chaukat in doors, windows skylights, fanlights and C/W celetial windows openings, including wedge over all clamps complete including application of two coats of wood preservative of approved quality on the surface buffing walls and lintels all complete as per building specification and direction of E/I.
Supplying, fitting and fixing 35mm thick solid core type non-decorative single leaf flush shutters in doors and windows with black board core bended with high quality phenol formal dehyde synthetic resin both side commercial veneered of standard make with oxidised iron fittings --- do ---
Providing and Fixing factory made uPVC door frame, made of uPVC exturded sections , of size 65 mm x 55 mm with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be mitred cut and jointed with plastic brackets and stainless steel screws, reinforcing hinge side vertical of the frames with PVC profile of Size 28 mm x 30 mm having wall thickness 2 mm (±0.2 mm), including providing & fixing 3 nos of 125 mm long stainless steel hinges to the frame, fixing the frame with jamb with required number & size of anchor dash fastners, all complete as per manufacturer's specification and direction of Engineer-in-charge.
Providing and fixing 37 mm thick factory made PVC door shutter, styles and rails made of PVC hollow section of size 100 mm x 37 mm with wall thickness 2 mm (± 0.2 mm), with inbuilt bead on one side, styles and rails mitered cut and joint at the corners by means of 2 nos of plastic brackets of size 75 mm x 220 mm at each corner and stainless steel screws, reinforcing the hinge side of style by inserting PVC profile of size 28 mm x 30 mm, with wall thickness 2 mm ( ± 0.2 mm). Lockrail of size 100 mm x 37 mm, wall thickness 2 mm (+ 0.2 mm) will be fixed to the vertical styles. Providing with PVC snapfit beads and panel of size 100 mm x 20 mm, and inserting 2 nos tie bar of 6 mm dia and fastening with nuts and washers complete, all as per manufacturer's specification and direction of Engineer-in-charge.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : Powder coated aluminium (minimum thickness of powder coating 50 micron).
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides. S.S.Fly Mesh
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineerin- charge. Pre-laminated particle board with decorative lamination on both sides
Supplying, fitting and fixing M.S.Grill gate with m.s.grills made of 20X6mm m.s.flats or 16mm m.s.square bars fitted on 25X25X6mm M.s.angle frame. --- do --- (when steel is not supplied by the deptt.).
Providing and fixing Stainless steel 304 grade for staircase railings, balconies, ramps with hand rail, 50mm dia 16 guage hollow pipe welded to vertical hollow 50mm dia pipe of 16 guage, stainless steel vertical pipe spaced at 1.20m regular intervals, and 5 Nos of 25mm dia. Stainless steel hollow horizontal pipe are welded to vertical 50mm dia hollow pipe. The entire assembly is fixed to staircase concrete by using expansion bolts by drilling concrete etc., complete including cost of materials, labour, HOM of machineries and electrical charges etc., complete as per specification.
Supplying, fitting and fixing callapsible gate of approved size and make property fabricated with virtical double channels 20X10X2 mm. at 100mm, centres and braced with M.S. flat diagonals 20X3 mm, with top and bottom rails of T. iron 40X40X6 mm with 38 mm dia steel pulleys completes with bolts, nuts, locking arrangements, stoppers, handles, including applying a promomg coat of red lear paint, car riage, hoisting and taxes all complete as per building specification ande direction E/I.
Providing, fabricating and fixing of stick type structural glazing using Alluminium Extrusions of 63.5mm58.00mm2.25mm of 1.73kgs/mtr for vertical and Horizontal members and 63.5mm38.11.33mm of 0.759kg/Mtr, as outer frame with Electro Anodized Paint coated block finishing, using 6mm thick imported glass reflective hard coated ocean blue raw glass with all necessary accesories like ultra glass Silicon sealant of Space tape, Masking tape, Galvanized Anchaor bolt, machine screws, 6mm thick M.S. angle 50mm150mm6mm M.S. Galvanized L Brackets, structural sealent setting clocks, fasteners, wall connection etc., complete.
Providing 12mm cement plaster (1:3) with clean coarse samd of F.M. 1.5 including screeinin, curing with all leads and lifts of water scaffolding taxes and royalty all complete as per building specification and direction of E/I.
Prodiding 12mm. Thick cement plaster (1:4). --- do ---.
Providing 25mm thick cement plaster (1:4) with clean coarse sand of F.M. 1.5 including screening, cutting with all leads and lifts of water, scaggolding taxed and royalty all complete as per building specification and direction of E/I.
Provising cement flush pointing (1:3) --- do --- do--
Making 6X6mm grooves in plaster surface over walls truly horizontal or vertical as specified at regular intervals at all heights including cleaning, finishing, scaffolding and cutting with all leads and lifts of water all complete as per buildingspecification and direction of E/I.
Providing and laying flooring using prepolished, water cut/gang saw 19mm thick granite laid over bed of 20mm thick 1:4 cm and jointed with neat cement slurry mixed with pigment to mach shade of granite slabs including laying POP on finished surface and clearning the surface, including the cost of all materials and labours etc., complete as per specification. -do- using silver grey granite/Multy Red/Ruby Red/Black/Hassan Green Granite of width not less than 1200mm
Providing and laying 25mm, thick kotah stone slab flooring of approved size, texture and colour over 19mm, thick base of lime mortar (1:1:1) (lime putty: surkh: coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing to granothic finish with approved quality of carborancum stone including cost of curing taxes and royalty all complete as per building specification and direction of E/I. (iv)600x600 mm size
Providing and laying 25mm thick kotah stone tiles in risers of steps, skirting and pillars of approves size, texture and colour laid over 12mm, thick cement mortar (1:3) and joined with grey cement slurry mixed with pigment to match the shade of the slab including rubing to granollithic finish with approved quality -do-
Providing and laying double charge Vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
15mm thick Granite work (machine cut, table rubbed & mirror polished) for kitchen platform, vanity counters, window sills and similar locations of required size laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) or 25mm th. kota slab support work including joints treated with white cement mixed with matching pigment including rubbing and polishing to edge moulding to give high gloss finish.Granite stone black
Providing and fixing on wall fade ----- do-----------do--------- 110 mm Diameter
Providing two coats of plastic emulsion paint of approved shade and make over a coat of cement primer over new surface including preparing plastered surface by rubbing smooth with pumice stone of fine sand paper, applying putty wherver required, scaffalding ---- do ---. extra for each coat of cement wash distemper, apint or snoeem over exterior surface for each consecutive floor above first floor including scaffolding etc all complete as per specification and direction of E/I.
Providing two coat of snowcem of approved shade and make over a coat of cement primer on new surface including preparing the plastered surface smooth with sand paper, scaffolding, curing and taxes all compete as per building specification and direction o E/O.
Providing two coat of snowcem of approved shade and make over a coat of cement primer on new surface including preparing the plastered surface smooth with sand paper, scaffolding, curing and taxes all compete as per building specification and direction o E/O. Extra for each coat of cement wash ......do....... E/I.
Water proofing for Old and New Roof Slab Providing and laying waterproofing treatment on roof slab by applying two Component, factory designed ready to use acrylic modified flexible material applied with brush roller or spray for Waterproofing as per manufacture r specification with following steps a)surface preparation: Providing and clearing or concrete surface to remove dust ,Oil grease including removal existing loose paint / Coating and cement balance by clearing with compressed air and water jet moulding at materials labour, tools complete. Ponding test to be done after plugging all outlets and to be checked to sort to from soft to identify seepage leakage. On identification of seepage, cement grouting to be done with non shrink expanding admixture of Sika India Pvt Ltd. /MYK Schomberg / Dr Fixit/FC Or equivalent. Providing and repairing of all corners and paints such as those between the parapet wall and the roof slab etc shall chartered with 150mm X 150 mm fillot of mortar (Cement sand 1:4) admixed with acrylic polymer of Sika / Fosroc / MYK Schornberg / Dr fixit or equivalent Before chamfering a prime coat shall be given with the slurry of acrylic polymer Repairing surface irregularites, damaged concretion base slab duao cracks it any with an acrylic polymer modified repair motar including a coat of bonding agent of the same with cement slurry including at material labour, tools complete. B) Lentes material on surface saturated dry roof st coat Apply 1st cost of the component acrylic modified ready to use. Flexible cementatious material or saturated dry roof and inside wait parapet wall 600 mm by brush or roller After 1st coat of application 45 gms of fibre glass cloth to lay when the first layer is still green.1st coat should be applied @ 150 kg/Sqmt/coat
for the purpose of measurement the entire treated surfave will be measured After 3 days of drying the for 48 hours identify seepage leakage from soft and if found necessary reinforcement to be donr as and Sika topseal 109h/ Fosroc Brushed RFX /Dr Fixit Pidiffin 2K /MYK Aqualin TG. Product performance – chemical base part A acrylic copolymer part B specially graded cementatious powder density 1:6 kg/ (mixed) at 27C Tesile strength – 2N/mm2 after 25 days (with fibre cloth ) Z( According to ISO 4624) Salnt shear bond strength -4N/mm (According to FIP 5.15) Elongation at break -35% without fibre cloth and 20% with fiubre cloth ( According to ASTM D 2370) (d) protection of treated surface with PCC – The treated surface should be covered with 25mm /50mm PCC of M-20 grade (1:1:5:3) with proper slope (1:120) towards the rain outlets in alternaters of 2 mt X 2mt keeping 6 mm gap b/w the panel jaint integral water proofing admixture conforming to IS 2645 @ of 100 ml per bag of cement to be added in the screed concrete (paid sperarately for this item) all corners shall be chamfered with 150mmX150mm . the rainwater outlets shall be just levelled with the screed concrete to ensure smooth discharge of water – the peripherial gaps between pvc pipe outlet & concrete surface should be packed properly with rich concrte & peripherial mouth to be sealed with moisture insensitive epoxy putty of sika india Pvt. Litd., (MYK Schomberg / Dr Fixit / Foscroc) for the purpose of measurement the entire treated surface will be measured € Groove of PCC sureface should be filled with Polysulphide sealeant (Paid separately) Brand – Sika India Pvt., Ltd / MYK Schomberg / Dr Fixit / Fosroc.
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes
Providing and installing of pre painted Galvolume iron Trapezoidal profiled sheet of approved make 1060 mm width (1000 mm cover width), 28-30 mm crest height with crest distance of 200 mm c/c with 2 ribs at the centre for stiffening. The total coated thickness (TCT) of the sheet will be 0.47 mm +/- 0.02 mm tolerance Zinc-Alu Alloy coating AZ150 gsm as per ASTM 1397/A755-550 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 20-22 microns using seif drilling/self tapping screws of 25 mm length, to be fixed over the existing purlins, rafters, channels and trusses.
---- do --- For Gutter.
----- do --- for Ridges
Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: 2.35.3.1 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as perdirection of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Providing and laying factory made chamfered edge Cement concrete paver blocks In foot path, park & lawns driveway or light & traffic parking etc. of required trength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of course sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, all complete as per manufacturer's specifications & direction of Engineerin- Charge.
SANITARY - PLUMBING WORKS.
Supplying, fitting and fixing 40mm high vitreous white glazed earthen E.W.C. with ‘p’ trap of parry hindustan or any other approved I.S.S. make including supplying and fixing 15 litres C.I. mosquito proof low down flushing cistern of approved make with complete fittings with C.I.handle and R.S. or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stop cock of approved quality weight not less than 450grams 15mm P.V.C. connection pipe 45cm. long with brass coupling at both ends and white/black plastic solid state seal and lead of commander/cuckoo or other I.S.S. make with hinges or screws etc. painting pipe and cistern etc. with 2 coats of approved paint over a coat of red oxide priming, all complete as per specification and direction of E/I.
Supplying, fitting and fixing vitreous white glazed earthen ware I.W.C. of parry Hindustan or any other I.S.S.approved make with 100mm H.C.I. ‘p’ trap 15 litres C.I. pull and let go flushing cistern of names or other I.S.S.equivalent make, complete with all fittings,C.I. or C.C.brackets 32mm alkathene/P.V.C. telescopic flush, pipe about 2 M long with one brass coupling and clamps G.I. chain and pull including supplying and fixing a pair of vitreous white glazed earthenware ware footrest to be fixed in floor 15mm C.I. body brass spindle stope cock of weight not less than 50grms, 15mm P.V.C. connection pipe 450 mm. long and the exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/I.
Supplying, fitting and fixing flat back or angular, lipped front vitreous white glazed earthen ware urinal of ‘Hindustan "Parry" or any other approved I.S.S make with 5 liters capacity C.I. automatic fulsing cistern of reliance for any other I.S.S. approved make with all fittings with C.I.or R.S. brackets, standard size G.I. flush pipe with fitting clamps, 15mm C.I. body brass spindle stop cock of approved quality weight not less than 400grams, 15mm P.V.C.connection pipe 450mm longwith brass coupling at both ends and doing plumber joints including painting of exposed part with two coats of approved paint over a priming coat of red oxide, cutting wall and floor, making good the same etc. all complete as per specification and direction of E/I.
Supplying fitting and fixing vitreous white glazed earthen ware wash hand basin of parry or Hindustan or any other I.S.S. approved make supported on painted C.I. or R.S. brackets 32mm C.I.brass waste, 15 mm dia C.I. body brass spindle stop cock of approved quality of weight not less than 350grams, 32mm P.V.C. waste pipe 750mm long with brass coupling at one end and making plumber joints etc. all complete as per specification and direction of E/I.
Supplying and fixing H.C.I. fittings of approved make confirming to I.S.S.1729 including supplying nails and bobines lead and yarn from making lead caulked joints including earth work or providing scaffolding as the case may be all complete as per specification and direction of E/I. FLOOR TRAP 100 mm Dia
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing Rectangular shape 453x357 mm
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931
Providing gun metal pillar cocks 15mm dia of I class conforming to ISI specifications and fixing them in position as per directions including of cost of materials and fixtures and conveyance to spot.
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.
Providing & fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and cost of cutting chases and making good the same including testing of joints complete. (concealed work including cutting chases and good the walls etc
15mm dia
20 mm dia:
25 mm dia:
Providing & fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step solvent cement, trenching, refilling and testing of joints complete. (External work).
25 mm dia:
40mm dia
50 mm dia:
62.5 mm dia.
75mm dia
Providing and fixing Stainless Steel pipe and fitting of grade AISI 304 as per JIS standard 3448 complete with press type fitting (fitting shall be paid for separately) i/c fixing of the pipe with clamps at 1.00 m spacing including cutting and making good the walls including testing of joints complete as per direction of Engineer-in-charge. (The pipe length inserted in the fitting shall not be measured for payment)
28.58 mm outer dia Pipe
42.70 mm outer dia Pipe
48.60 mm outer dia Pipe
P/F Automatic sensor taps of approved make with D/C power supply as per manufactureres specifications.
Providing and fixing gun metal wheel valve conforming to IS specification of approved make as per directions including all lead and lift etc., complete
50 mm dia:
40 mm dia:
25 mm dia:
P/F. rigid PVC soil pipes of I.s. approved make with gum joints including cost of specials such as door bends, bends, Y, T, door T, reducers etc. as required, making wall or foundation bores & redoing, earthwork excavation & refilling, water testing etc. complete as per instructions.
110 mm dia:
75 mm dia:
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design
150 X 100 mm Size
180 X 150 mm Size
P/C. Inspection chambers, using approved quality burnt bricks in c.m. 1:4, 230 mm thick walls built over 100 mm thick bed of P.C.C. 1:3:8, channelling smooth finish, plastering in c.m. 1:3 15 mm thick . The chamber covers shall be of heavy duty SFRCof approved make & size with frame fixed flush with the paving level in c.c. 1:2:4.
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : 19.7.1 Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : 19.7.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Extra for depth for manholes : 19.8.1 Size 90x80 cm 19.8.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design
100mm dia
150mm dia
200mm dia
Providing and fixing Stainless Steel A ISi 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :
Kitchen sink without drain board 610x510 mm bowl depth 200 mm
Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms.
NP2 Pipe( RCC)
Labour for laying ( to level or slopes) and joining reinforced concrete light duty no-pressure pipes I.S. class NP2 of the following international diameter with collars and butt ends prepared for collar joints including testing of joints complete. (D) 300mm (upto 10ton)
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
ELECTRICAL WORKS
Point Wiring in PVC Conduit, with Modular type Switch: Wiring for light point/ fan point/ exhaust fan point/ call bell point with 3 x 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, with modular type switch, modular plate, suitable size of GI box etc as required.
Group C (avg length 5.0 mts) - 1L/1S
Group C (avg length 8.0 mts) - 2L/1S
Group C (avg length 11.0 mts) - 3L/1S
Twin Control point wiring in PVC conduit, with maodular type switch :- Wiring for twin control light point with 1.5 Sqmm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit, 2 way modular type switch, modular plate, suitable size G.I box etc. as required - 2L / 2 nos. 2 way switch (avg length 5.0 mts) -
Same as above but with - 1L / 2 nos. 2 way switch (avg length 3.0 mts)
Supply and Fixing Light Plug Point with Modular Type Accessories: Supply and Fixing GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch, connection, painting etc as required.
Supply and Fixing Light Plug Point with Modular Type Accessories: Supply and Fixing GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular type switch, connection, painting etc as required.
Power Plug Wiring in PVC conduit (2x4 sq. mm): Wiring for light/power plug with 2x4 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit along with 1 number 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Circuit / Sub-main wiring in PVC Conduit: Wiring for circuit / sub-main wiring along with earth wire with the following sizes of PVC insulated, copper conductor, single core cable in surface/recessed PVC conduit as required.
2 X 1.5 Sqmm + 1 X 1.5 Sqmm earth wire in 20 mm dia PVC conduit
2 X 2.5 Sqmm + 1 X 2.5 Sqmm earth wire in 20 mm dia PVC conduit
2 X 4.0 Sqmm + 1 X 4.0 Sqmm earth wire in 20 mm dia PVC conduit
2 X 6.0 Sqmm + 1 X 6.0 Sqmm earth wire in 25 mm dia PVC conduit
2 X 16.0 Sqmm + 1 X 16.0 Sqmm earth wire in 32 mm dia PVC conduit
4 X 2.5 Sqmm + 2 X 2.5 Sqmm earth wire in 25 mm dia PVC conduit
4 X 4.0 Sqmm + 2 X 4.0 Sqmm earth wire in 25 mm dia PVC conduit
4 X 6.0 Sqmm + 2 X 6.0 Sqmm earth wire in 32 mm dia PVC conduit
4 X 10.0 Sqmm + 2 X 10.0 Sqmm earth wire in 32 mm dia PVC conduit
4 X 16.0 Sqmm + 2 X 16.0 Sqmm earth wire in 40 mm dia PVC conduit
S/F S.P MCB DB:- supplying and fixing following way single pole netrual, sheet, MCB distribution board, 240 volts, on surface / recess complete with tinned copper bus bar, neutral busbar, earthbar, din bar, detachable gland plate, interconnection, phosphatized and powder painted including earthing, etc. as required (But without MCB/RCCB/Isolator)
8 way, double door
12 way, double door
16 way, double door
S/F T.P. MCB DB:- Spplying and fixing following way, three pole and neutral, sheet, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required . (But without MCB/RCCB/isolator)
4 way (4 + 12), Double door, horizontal type
6 way (4 + 18), Double door, horizontal type
S/F Vertical type T.P MCB DB:- Suplying and fixing following way, three pole and neutral, sheet, MCB distribution board, 415 volts, on surface / recess , complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnetions, phosphatized and powder painted including earthing etc, as required.( But without MCB/ RCCB/ Isolator) Note:- Vertical type MCB TPDB is normally used where three phase outlets are required.
8 way (8 + 24), Double door, vertical type
S/F SP MCB blanking plate:- Supplying and fixing single pole blanking plate in existing MCB DB complete etc, as required
S/F TPN RCCB: Supplying & fixing following rating, TP&N 415 V, residual current circuit breaker (RCCB) , having a sensitivity current upto 300mA in existing MCB DB complete with connections, testing and commissioning etc. as required.
S/F 'C' series following MCB: Supplying and fixing 240/415 volts, 'C' series, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc, as required.
6/32A Single Pole
6/32 amps, DP
50/63 amps, DP
6/32 amps, TPN
50/63 amps, TPN
S/F Modular type Switch / Socket: Supplying and fixing following modular type switch / socket on the existing modular plate and switch box including connections but excluding modular plate etc as required.
5/6 amps, one way switch
15/16 amps, one way switch
5/6 amps, 3 pin socket outlet
15/16 amps, 6 pin socket outlet
Telephone socket outlet
TV antenna socket outlet
S/F modular boxes, base & cover plate:- Supplying and fixing following size / modules G.I box along with modular base & cover plate for modular switches in recess etc, as required
1 or 2 module(78mm X 78mm X 45mm)
4/5 module(78mm X 140mm X 50mm)
6 module(78mm X 205mm X 50mm)
8/9 module(78mm X 230mm X 60mm)
Supplying and fixing Modular type blanking plate-Supplying and fixing modular blanking plate on existing modular plate switch box excluding modular plate etc. as required.
S/F Ceiling Rose: Supplying and fixing 2 pin 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
S/F Batten Holder: Supplying and fixing batten/angle holder including connection etc. as required.
ITC fluorescent fitting directly on surface :- installation testing and commissioning of Pre - wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc, directly on ceiling / wall, including connection with 1.5 Sq. mm. FR PVC insulated, copper cond. -LED light fixtures
Supply of 20W LED Ceiling/ wall mounted light fixture with necessary fixing accessories as required
Supply of 10W LED(2') Ceiling/ wall mounted light fixture with necessary fixing accessories as required
Supply of 15W Recess mounting LED round down light with necessary fixing accessories as required
Supply of ceiling fan 48" (1200 mm)
ITC Ceiling Fan :- Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (Up to 30 cm) with 1.5 sq. mm. FRPVC insulated,copper conductor,single core cable etc, as required.
S/F Modular type electronic fan regulator: Supplying and fixing stepped type fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as required.
Supply of Exhaust fan 12" (300 mm)
ITC Exhaust Fan upto 450 mm sweep: installation of exhaust fan upto 450 mm sweep in the existing opening, including making the hole to cut the size of the above fan, making good the damage, including connection, testing, commissioning etc as required.
Telephone Wiring in Existing Conduit: Supplying and drawing, following pair, 0.5 sq.mm FR PVC insulated copper conductor, unarmoured telephone cable in the existing surface / recessed steel / PVC conduit as required.
Supplying and drawing Co- axial TV cable RG-6 grade copper conductor PE insulated, with PVC sheath in existing surface / recessed PVC conduit as required
S/F PVC Conduit: Supplying and fixing of following sizes of PVC conduit along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required.
20 mm ( for telephone + PA + FA)
25 mm ( for TV + Data + CCTV)
Supply of PVC/XLPE insulated PVC sheated, heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100Volts ( Confirms to IS : 1554, part-1)
10 Sq. mm, 4 core
16 Sq. mm, 4 core
25 Sq. mm, 3.5 core
35 Sq. mm, 3.5 core
150 Sq. mm, 3.5 core
185 Sq. mm, 3.5 core
240 Sq. mm, 3.5 core
with stand and protective covering
MV cable laying upto 25 Sq.mm. in ground
Laying of one number PVC insulated and PVC sheathed /XLPE power cable of 1.1 KV grade of size not exceeding 25 Sq.mm direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required
MV cable laying upto 120 Sq.mm. in ground
Laying of one number PVC insulated and PVC sheathed /XLPE power cable of 1.1 KV grade of size exceeding 25 Sq.mm but not exceeding 120 Sq.mm direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required
MV cable laying upto 400 Sq.mm. in ground
Laying of one number PVC insulated and PVC sheathed /XLPE power cable of 1.1 KV grade of size exceeding 120 Sq.mm but not exceeding 400 Sq.mm direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required
MV cable laying upto 25 Sq.mm. in same trench
Laying of one number additional PVC insulated and PVC Sheathed/ XLPE power cable of 1.1 KV grade of size not exceeding 25 Sq.mm direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required
MV cable laying upto 120 Sq.mm. in same trench
Laying of one number additional PVC insulated and PVC Sheathed/ XLPE power cable of 1.1 KV grade of size exceeding 25 Sq.mm size not exceeding 120 Sq.mm direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required
MV cable laying upto 400 Sq.mm. in same trench
Laying of one number additional PVC insulated and PVC Sheathed/ XLPE power cable of 1.1 KV grade of size exceeding 120 Sq.mm but not exceeding 400 Sq.mm direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required
GI earth pipe electrode with salt/charcoal:- earthing with GI earth pipe 4.5 mtr long 40 mm dia including accesories and and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with cahrcoal and salt as required.
Copper earth plate electrode:- earthing with copper earth plate 600mm x 600mm x 3mm thick including accesories and and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. as required.(but without cahrcoal or coke and salt )
Extra Salt & Charcoal for Copper Earth Plate Elecrode:- Providing and fixing salt and charcoal or cock for copper earth plate elecrode complete etc as required.
P/F 25 mm x 5mm copper earth strip in surface / recess :- providing and fixing 25 mm x 5mm copper strip on surface or in recess for connections etc.,, as required.
S/L 25 mm x 6mm GI earth strip in ground:- supplying and laying 25 mm x 6mm GI strip at 0.50 metre below ground as strip earth electrode, including soldering etc. as required.
P/F 6 SWG GI loop earthing wire in surface / recess :- providing and fixing 6 SWG dia GI wire on surface or in recess for loop earthing as required.
P/F 4mm copper loop earthing wire in surface / recess :- providing and fixing 4mm dia copper wire on surface or in recess for loop earthing as required.
7 Mtr. Height octagonal hot - Dip galvanized pole ( BOP - 7030) with top dia 70mm, bottom dia 130mm & made of 3 mm thick sheet, base plate dimensions 200 X 200 X 12 mm (L X B X T) including suitable sizes of foundation bolt all complete as required ( without Arm)
Erection of metallic street light standard pole of length exceeding 6.5 meters but not exceeding 8.5 meter in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation with cement concrete collar of size 0.4 m dia X 0.5 m height to accommodate the looping type cable end box including exvavation and refilling etc. as required
11 mtr height octagonal hot - Dip galvanized pole ( BOP - 1131) with top dia 70 mm bottom dia 175 mm & made 3 mm thick sheet, base plate dimensions 275 X 275 X 16 mm (L X B X T) ncluding suitable sizes of foundation bolt all complete as required ( without Arm)
Erection of steel tubular pole of length exceeding 10meters but not exceeding 12 meters in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including exvavation and refilling etc. as required
1m Single Arm suitable for 70mm Top
1m Double Arm suitable for 70mm Top
Supply, installation, erection, testing and commissioning of street light. The light fixture shall be mounted on existing pole . The rate shall include the cost of necessary fixing accessories all complete as required. LED Street light 45W
Supply, installation, erection, testing and commissioning of flood light. The light fixture shall be mounted on existing pole. The rate shall include the cost of necessary fixing accessories all complete as required. LED Flood light 120W
Supply, installation, erection, testing and commissioning of bulk head light fixture. Bulkhead fitting with 10W LED.
supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm normal size) of size 60cm x 60 cm at the bottom and 50mm x 50mm at the top with a thickness of 10cm including inscription duly engraved as required.
P/F M V danger notice plate:- Providng and fixing MV danger notice plate of 200mm X 150mm, made of mild steel, at least 2mm thick, and vitreous enamelled white on both sides and with inspection in single red color on front side as required.
TOTAL SCHEDULE ITEMS( A )
NON SCHEDULED ITEMS (B)
CIVIL WORKS
Providing & fixing 2mm th. Profiled Polycarbonate sheet (matching the roof sheet profile) fixed over aluminium/m.s. support works with necessary accessories, fixtures etc., complete.
P/L P.C.C.(1:4:8) using 40mm & down size metal with clean river sand with top plastering in c.m.(1:3), 12mm th including surface preparation like compacting the soil etc. complete for paving alround the building.
: Providing and fixing plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. (length of mesh only be measured for payment)
Providing and fixing 3m long 25mm dia TMT dowel bars 1.5m inserted in 50mm dia holes drilled in hard rock and grouting in CM 1:1 including necessary bending, hooking, cutting and handling charges complete, including the cost of steel. (MORTH clause 1200)
P/F. UPVC or equivalant approved make Pipes (Supreme or equivalent make) with malleable specials such as tee, bend, elbow, socket, reducing sockets, union, collers etc. as required including cutting, threading and fixing with necessary plumbers gum, making earthwork excavation and re-filling or making wall grooves and re-doing after testing, . specials laid under ground or consealed pipe line etc. complete.
16 mm dia.
20 mm dia.
25 mm dia.
PLUMBING WORKS
P/F. UPVC or equivalant approved make Pipes (Supreme or equivalent make) with malleable specials such as tee, bend, elbow, socket, reducing sockets, union, collers etc. as required including cutting, threading and fixing with necessary plumbers gum, making earthwork excavation and re-filling or making wall grooves and re-doing after testing, . specials laid under ground or consealed pipe line etc. complete.
40 mm dia.
50 mm dia.
65 mm dia.
P/F. I.S.I. Approved make, S.S. Ball valves, fixing in the water supply lines with threaded joints.
25 mm dia.
40 mm dia.
50 mm dia.
P/F. rigid PVC soil pipes of I.s. approved make with gum joints including cost of specials such as door bends, bends, Y, T, door T, reducers etc. as required, making wall or foundation bores & redoing, earthwork excavation & refilling, water testing etc. complete as per instructions.
150mm Dia
Providing and laying Eco drain pipes (Supreme or equlenta) with necessary specials like bends, wooden plugs including Laying in position PCC M7.5 20mm and down size graded granite metal, machine mixed concrete laid in layers not exceeding 15 cms thick, well compacted, scaffolding including cost of materials, labour charges, HOM of machinery, curing complete as per specifications etc., as per directions.
110mm dia
160mm dia
200mm dia
Providing & Constructing floor drains,400mm wide, 75 - 250mm deep with 115 th. Brick masonry over PCC (1:4:8) bed 10 cm thick, providing & fixing 20mm thick m/c & mirior polished Hassan green granite slabs with chamfered joints, 4mm thick perforated S.S. removable cover etc complete as per details.
100mm dia
P/F. Redimade septic tank of 50 users including excavation, refilling,fixing of 75 mm vent cowl And waterproof plastering bottom,ceiling, inside etc as per manufacturer specification .complete.
Design, supply, construction, installation of Effluent Treatment Plant(ETP) (Package Type) suitable for treating 25 KLD (Kilo Litres per Day) of Effluent which is coming from kitchen, Canteen,staff dormitory & Guest House complete in all respects on FBBR basis including design and construction of structures for various units, supply and installation of mechanical, electrical equipment, instruments along with all piping works and other connected works required to provide complete operatable plant including testing & commissioning the plant and trial running of the plant for a period of 6 months
Borewell Drilling + Casing (Considering 500ft) with KSB 3HP 3 PHASE SUBMERSIBBLE PUMP with starter and all fittings .
MONO BLOCK PUMP KSB 1HP 1INCH OUTLET , 1 INCH INLET
ELECTRICAL WORKS
MS CONDUIT WIRING :
Supply & Wiring for Lights, Ceiling fans, exhaust fan and 6A socket outlets using 1.5 sqmm flexible copper, 1100 volts grade PVC insulated FRLS wires drawn through 2mm thick, suitable size FRLS MS conduit in concealed manner using necessary conduit accessories like junction boxes, Switch boxes, bends, collars, clamps, ceiling roses, 6A/16A switches, Fan regulator and hook boxes, etc., and shall be flush mounted in brick wall or in the built up furnitures or on the surface of wall for surface installation as required. The rate for point wiring shall include the wiring from distribution board to control switches/ light/fan then looping between lights/fans/6A socket outlets etc., Also the rate shall include earthing of each light, fan outlet boxes, switch control boxes, 6A sockets using 1.0sqmm, flexible, copper conductor, PVC insulated wires. (Switches & Sockets shall be of modular type of make Myrius of Legrand / equivalent).
Single light point controlled by a 6A SP switch. (avg length-5.0 mts)
Two light point controlled by a 6A SP switch. (avg length-8.0 mts)
Three light point controlled by a 6A SP switch. (avg length-11.0 mts)
Lighting Wiring /Power wiring/Submains: (M.S CONDUIT)
Supply and wiring for circuit mains using flexible, copper 1100V grade, PVC insulated, FRLS wires drawn through 16G mm thick suitable size MS conduit with all necessary accesories like bends, elbows, junction boxes etc., (The light Circuit mains will be measured in running meters from distribution board upto the first light/switch point or fan or 5A first socket outlet point whichever nearer. then onwards it will be included in point wiring)
2Nos. 2.5sqmm +1No. 2.5 sqmm copper wires in 20mm dia MS conduit.
4Nos. 2.5sqmm +2No. 2.5 sqmm copper wires in 25mm dia MS conduit.
4Nos. 6.0 sqmm + 2Nos. 6.0 sqmm copper wires in 25mm dia MS conduit.
Supply and fixing IP-55 of 1-ø / 3- ø combination 3/5 pin industrial type interlocked socket controlled by a TP/SP MCB housed in enclosure. The rate shall include providing of plug top & MCB. -16A, 2pin, 1-ø, controlled by 16A, DP, MCB with plug top
16A, 5pin, 3-ø, controlled by 16A, 4P, MCB with plug top
Supply and fixing IP-66/67 of 1-ø / 3- ø combination 3/5 pin industrial type interlocked socket controlled by a TPN/SP MCB housed in enclosure. The rate shall include providing of plug top & MCB. -32A, 5pin, 3-ø, controlled by 16A, 4P, MCB with plug top
Supply & installation of 16A Switched-Socket IP66 in Enclosure of type 86893GRY of MK make. (Note: Wiring and conduit will be measured separately.)
Supply & installation of din rail mounted, modular digital time switch of 16A for street light control similar to Legrand Alpha Rex 3 D21 or other approved make with one channel daily & weekly time swich.
Supply & installation of SP metal Enclosure to mount MCB. The rate shall include cost of necessary fixing accessories as required. The rate shall exclude the cost of MCB
Supply & installation of DP metal Enclosure to mount MCB. The rate shall include cost of necessary fixing accessories as required. The rate shall exclude the cost of MCB
Supply and fixing of single phase, 450 mm dia 900 RPM, heavy duty exhaust fan with necessary angle iron bracket.
Supply, installation, testing and commissioning following sizes isolator in metal enclosure . The isolator shall be wall mounted using necessary brackets and fixing accessories.
Supply and laying of 16G M.S conduit with all necessary accessories like junction boxes, pull boxes. G.I fish wires and other fixing accessories as required.The rate shall also include chasing of walls, floor and plastering of the chased portion etc all complete as required. -20 mm dia
25 mm dia
32 mm dia
Supply of ceiling fan 36" (900 mm) of havells make/equivalent
Supply of ceiling fan 24" (600 mm) of havells make/equivalent
Supply of 1100V grade, XLPE/ PVC insulated, PVC sheathed, Aluminium / copper conductor, steel armoured cables. The cable shall be laid in exsiting trench, cable tray / clamped on to the walls using necessary fixing accessories. The cable shall be provided with cable identification tags made out of Aluminium strip, engraved with cable size and the routing.
4C 6 Sq mm XLPE Al. arm Cable
3C 10 Sq mm XLPE Al. arm Cable
3C 6 Sq mm XLPE Al. arm Cable
3C 4 Sq mm XLPE Al. arm Cable
3C 2.5 Sq. mm Cu arm Cable
CABLE END TERMINATIONS: Supply and providing end termination for below listed PVC insulated, PVC sheathed, aluminium conductor, steel armoured, 1100V grade, cable using double compression brass cable glands and aluminium lugs etc, all complete as required.
3.5C 240 Sq. mm XLPE Al. arm Cable
3.5C 185 Sq. mm XLPE Al. arm Cable
3.5C 150 Sq.mm XLPE Al. arm Cable
3.5C 35 Sq. mm XLPE Al. arm Cable
3.5C 25 Sq. mm XLPE Al. arm Cable
4C 16 Sq. mm XLPE Al. arm Cable
4C 10 Sq. mm XLPE Al. arm Cable
4C 6 Sq. mm XLPE Al. arm Cable
3C 10 Sq. mm XLPE Al. arm Cable
3C 6 Sq. mm XLPE Al. arm Cable
3C 4 Sq. mm XLPE Al. arm Cable
3C 2.5 Sq. mm Cu arm Cable
Supply and fixing of hot dipped galvanized GI ladder type cable tray conforming to IEC- 61537. The cable tray shall be supplied in standard length of 3000mm. The rung size shall be of 30x15mm size suitable for fixing the cable clamps the space between them shall be 300mm. The rate shall include cost of necessary fixing accessories as required. -300mm width x 75mm height x 1.5 mm thick
200mm width x 75mm height x 1.5 mm thick
Straight connector for 75mm Height
Angle connector for 75mm height
Adjustable connector for 75mm height
Supply and fixing of MS support made out of Mild steel of adequate size suitable supporting for cable trays, cables, conduits. The supports shall be ceiling suspended type / wall bracket type clamps with necessary accessories for fixing of cable trays, cables, conduits as per site requirement. The supports shall be provided at every 1.5 M span and at bends / crossings. The painting for MS frame work with two coats of enamel paint of approved colour over a coat of premier. The contractor shall submit the GA drg for typical supports and on obtaining the approval from Architect/Consultants.
Supply of 7W LED Mirror light fixture of type LCL-07-CDL of CG make/equivalent. with necessary fixing accessories as required
Supply of 21W LED Surface mounted light fixture of type ENDURANEOSURFA CEDLS21WLED857S of HAVELLS make/equivalent. with necessary fixing accessories as required
Supply of 36W LED (2'X2') recess mounted light fixture of type LCTLRN-36-CDL of CG make/equivalent. with necessary fixing accessories as required
Supply of 40W LED Ceiling / wall mounted light fixture of type STOUTPLUS1200BS40WLED857SPCWH of Havells make/equivalent. with necessary fixing accessories as required
Supply of 40W LED, IP65 Industrial, High bay light fixture of type LWVLT-40-CDL of CG make/equivalent. with necessary fixing accessories as required
Supply of 12W, LED Surface mounted light fixture of type LCSR-12-CDL of CG make / equivalent. with necessary fixing accessories as required
Supply of 1 x 18 W CFL, Post top light fixture of type 5840 of K-lite make/equivalent. with necessary fixing accessories as required
Supply, installation, testing and commissioning of gate light pole of MS pole of 50 mm dia, 600 mm long, of which 300mm above the brick wall and 300mm embeded in brick work along with 16 G, 19 mm, PVC conduit & other necessary accessories like reducer all complete as required.
Supply, installation, testing and commissioning of M.V. panels and switch gears suitable for 415V, 3 phase, 4 wire, 50Hz power distribution system. The panel shall be free standing floor mounting type 14G/16G sheet steel enclosed, flush front with single aluminium bus bars and separate earth bus to be provided through out the length of the panel. The incoming and out going feeders breakers, changer over switches, fuses indicating lamps shall be accomadated in a modular multitier arangement. Minimum clearance of 400mm shall be provided from the floor level to the bottom most termination point adequate size cable alley and bus bar chamber shall be provided ,all round the panel and it shall be connected through solid bus bars. Flexible cable links are not acceptable .
Bus bars shall be provided with sleeves or heat resistant insulated paint. The paint shall be suitable for both top/bottom cable entry. The minimum fault rupturing capacity of all incoming and out going breakers/ switches shall be as per SLD only.The panel shall be painted in conformity with the relevant IS code.The panel shall be fabricated only after obtaining approval of the GA drawings. The rate shall also include cost of civil works including fixing accessories, all complete as required. Apporexmate size (Shall be given at the time of work order)
LT Meter Board sealable (Outdoor type) -Annakhetra : (as per dwg no.APK/PECS-1833/SCH-01) (As per Electricity Board requirement) INCOMER - a) 1 set of SP fuse cutout b) 1 no. kWH meters (Space provision) c) 3 no. 6A SP MCB
LT Meter Board sealable (Outdoor type) -Make shift kitchen ::(as per dwg no.APK/PECS-1833/SCH-01) (As per Electricity Board requirement) INCOMER - a) with CT & PT suitable for 25.0kW load b) 1 set LED TYPE PHASE INDICATING LAMPS R, Y, B c) 1 no. kWH meters (Space provision) d) 3 no. 6A SP MCB
Incomming Breaker Panel (Outdoor type) :(as per dwg no.APK/PECS-1833/SCH-01) INCOMER - a) 1 no. 200A, TPN, MCCB, thermal based b) 3 no. LED TYPE PHASE INDICATING LAMPS R, Y, B
SDB - Make shift :(as per dwg no.APK/PECS-1833/SCH-01) INCOMER - a) 1 no. 63A, 4P, Thermal based MCCB, b) 2 sets LED TYPE PHASE INDICATING LAMPS R, Y, B c) 6 no. 6A, SP, MCB d) 1 no. dual source kWH meter e) 2nos. MDM meter. f) 1 Set. 63/5A, CL:1, 10VA RESIN CAST CURRENT TRANSFORMER FOR metering g) 1nos. 1 Pole Earth Leakage Relay, 1-8 Amps, 1C/O, CBCT RESIN CAST 200MM Inner dia h)1 no. 63A 4P ATS OUTGOINGS : a) 2 nos. 16A, SP MCB b) 1 nos. 20A, SP MCB c) 3 nos. 16A, TPN MCB d) 2 nos. 25A, TPN MCB
STATERS OUTGOINGS : A] 2 nos. 5HP DOL Starter, Each consisting of following i) Incomer : 10A, TPN MPCB. ii) AC3 duty power contactor -25A iii) OLR range 6-10A with ON & OFF push buttons and indicating lamps with control MCB's (Option fot remote ON & OFF to be made available) B] 1 nos. 3HP DOL Starter, Each consisting of following i) Incomer : 6.3A, TPN MPCB. ii) AC3 duty power contactor -25A iii) OLR range 4.5-7.5A with ON & OFF push buttons and indicating lamps with control MCB's (Option fot remote ON & OFF to be made available) C] 3 nos. 2HP DOL Starter, Each consisting of following i) Incomer : 4A, TPN MPCB. ii) AC3 duty power contactor -12A iii) OLR range 3-5A with ON & OFF push buttons and indicating lamps with control MCB's (Option fot remote ON & OFF to be made available) BUS BAR : 63A TPN ALUMINIUM BUS BAR
Modification of existing LT Meter Board sealable (Outdoor type) by providing new CT suitable to accommodate the measurement of additional load of 60.0kW. The rate shall include cost towards tertiary/approval from EB
Main Panel MAIN KITCHEN : (as per dwg no.APK/PECS-1833/SCH-01) INCOMER - a) 2 nos. 200A, 4P, Thermal based MOTORIZED MCCB, 1 no. 63A, 4P, Thermal based MOTORIZED MCCB, b) 3 sets. LED TYPE PHASE INDICATING LAMPS R, Y, B c) 18 no. 6A, SP, MCB d) 3 sets. LED TYPE ON, OFF, TRIP INDICATING LAMPS e) 2 nos. MDM meter., 1 no. MDC meter. f) 1 no. 63/5A, CL:1, 10VA RESIN CAST CURRENT TRANSFORMER FOR metering g) 2 no. 200/5A, CL:1, 10VA RESIN CAST CURRENT TRANSFORMER FOR metering h) 3nos. 1 Pole Earth Leakage Relay, 1-8 Amps, 1C/O, CBCT RESIN CAST 200MM Inner dia i) 1nos. 63A 4P, Thermal based MCCB (Buscoupler)
OUTGOINGS : a) 5 nos. 63A, TPN MCB b) 3 nos. 40A, TPN MCB c) 4 nos. 25A, TPN MCB d) 3 nos. 16A, TPN MCB e) 1 nos. 25A, SP MCB f) 3nos. 63A, TPN, Thermal based MCCB, APFC : incomer a) 1 nos. 63A, TPN, Thermal based MCCB, APFC : outgoing a) 2 nos. 10A, TP MCB & contactor b) 2 nos. 16A, TP MCB & contactor c) 2 nos. 25A, TP MCB & contactor d) 6 no. LED TYPE ON, OFF, INDICATING LAMPS e) 1 no. 2KVAR Capacitor, 1 no. 3KVAR Capacitor f) 2 no. 5KVAR Capacitor, 1 no. 10KVAR Capacitor g) 1 no. APFC relay (6stage) BUS BAR : 200A TPN ALUMINIUM BUS BAR
Pump panel INCOMER - a) 1 no. 63A, TPN, MCCB, Thermal based b) 3 no. LED TYPE PHASE INDICATING LAMPS R, Y, B c) 3 no. 6A, SP, MCB d) 1no. VAF meter. e) 1 no. 63/5A, CL:1, 10VA RESIN CAST CURRENT TRANSFORMER FOR metering f) 1nos. 1 Pole Earth Leakage Relay, 1-8 Amps, 1C/O, CBCT RESIN CAST 63MM Inner dia OUTGOINGS : a) 7 nos. TPN MCB BUS BAR : 63A TPN ALUMINIUM BUS BAR
SDB Ground floor :(as per dwg no.APK/PECS-1833/SCH-01) INCOMER - a) 1 no. 63A, 4P, Thermal based MCCB, b) 2 sets LED TYPE PHASE INDICATING LAMPS R, Y, B c) 6 no. 6A, SP, MCB d) 1 no. dual source kWH meter e) 1 Set. 63/5A, CL:1, 10VA RESIN CAST CURRENT TRANSFORMER FOR metering f) 1nos. 1 Pole Earth Leakage Relay, 1-8 Amps, 1C/O, CBCT RESIN CAST 200MM Inner dia
OUTGOINGS : a) 3 nos. 16A, TPN MCB b) 2 nos. 25A, TPN MCB STATERS OUTGOINGS : A] 2 nos. 5HP DOL Starter, Each consisting of following i) Incomer : 10A, TPN MPCB. ii) AC3 duty power contactor -25A iii) OLR range 6-10A with ON & OFF push buttons and indicating lamps with control MCB's (Option fot remote ON & OFF to be made available) B] 2 nos. 3HP DOL Starter, Each consisting of following i) Incomer : 6.3A, TPN MPCB. ii) AC3 duty power contactor -25A iii) OLR range 4.5-7.5A with ON & OFF push buttons and indicating lamps with control MCB's (Option fot remote ON & OFF to be made available) C] 3 nos. 2HP DOL Starter, Each consisting of following i) Incomer : 4A, TPN MPCB. ii) AC3 duty power contactor -12A iii) OLR range 3-5A with ON & OFF push buttons and indicating lamps with control MCB's (Option fot remote ON & OFF to be made available) BUS BAR : 63A TPN ALUMINIUM BUS BAR
Supply and installation of Class-A, G.I Pipe for cables. The rate shall include, pipe accessories, sealing of pipe entries, fixing accessories etc., all complete as required.- 50 mm dia
100 mm dia
Supply and installation of DWC HDPE pipe. The rate shall include, pipe accessories, sealing of pipe entrys, fixing accessories. The rate shall exclude cost of excavation and back filling and ramping of filled soil etc., -50 mm outer dia/38mm inner dia
110 mm outer dia/94mm inner dia
160 mm outer dia/135mm inner dia
Supply and installation of 25 x 3 GI strip with necessary fixing accessoriea as required.
Excavation of trench of 600 mm deep and of required width for laying of cables/ humepipes. The rate shall also exclude cost of sand cushioning, brick protection and refilling, the excavated portion and consolidating etc., as required.
Supply and laying of sand cushioning for under ground cables laid in existing trench.
Supply and laying of brick protection for under ground cables laid in existing trench.
Construction of brick masonry inspection chambers of internal clear dimension as mentioned below by using first class table moulded modular bricks 230 mm thick wall in cement mortor joints in 1:6, over CC 1:4:8 bed 100 mm thick including providing precast RCC top slab in 1:2:4 Mix (1 cement: 2 oarse sand: 4 graded stone aggregate), with angle iron frame, inside plastering 15mm thick with CM 1:4 (1 cement:4 fine sand) finished very smooth with floating coat of neat cement & making benching and channelling in cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate) neatly finished complete as per standard design and as per drawing and specifications. (The rate shall include necessary earth work excavation in all types of soil excluding soft and hard rock, back filling including consolidation disposing the excess earth to all leads curing, finishing etc.,)
Inside size of 600 x 600 mm depth not exceeding 750mm including providing 600 x 600mm RCC cover.
Inside size of 750 x 750 mm depth not exceeding 900mm including providing 750 x 750mm RCC cover.
Supply and fixing in position approved shock treatment chart written in English, Hindi and local language. The chart shall be framed in teakwood frame and covered with glass.
Supplying 4.50 Liter / Kg CO2 fire extinguishers with connected accessories complete jainex / minimax make.
Supply and fixing in position 4 fire buckets of 9Ltrs capacity with floor stand, sand, painting etc.
Supply & laying of rubber mats of 11kv grade, 1.8.mtr. x 0.9mtr. And of sufficient thickness as required by the Electrical Inspectorate and confirming to IS 15652.
Supplying of first Aid box containing medicines for 50 persons to give first aid treatment.
Supplying rubber gloves of electrical quality tested to 22 KV.
Supplying & installing of multicore 0.5mm, copper conductor, PVC insulated, PVC sheathed, armoured telephone cable laid drawn through, existing trench/tray/wall with all necessary accessories as required. -20 pair cable
10 pair cable
5 pair cable
Supplying, installation, testing & commissioning of telephone junction box. The junction box shall be with sheet steel enclosure enclosing krone connector and shall be provided with padlock arrangement. - 20 pair TJB
10 pair TJB
5 pair TJB
Supply and installing of 30 X 30 pair (duplicate) Disconnect type with fuse protection (for incoming DOT lines) for main distribution frame for terminating EPABX side & building internal telephone wiring.
Supply, installation, testing and commissioning of digital EPABX with following features, 2 nos. Analog Trunk Interface 24 Nos. Analog Extensions Interface Built in Interface for External Music on Hold Built in basic ACD feature Caller ID on Analog & digital extensions Voice Guided DISA Auto Attendant Built-in Remote maintenance Built in Least Cost Routing Built in Interface for External paging system Inbuilt Power supply 1no. Digital operator console
Supply, installation, testing and commissioning of Analog table mounted telephone instruement of type C51 of Beetel make / equivalent.
Supply, installation of RJ-45, compatable information outlet with necessary back mount box and other fixing accessories. (The socket outlet shall be of make Myrius of Legrand /equivalent) The rate shall also include cost of civil works involved in fixing of boxes.
Supply and connecting of UTP cat -6 mounting cords - 4' 0" long
Supply, installation, testing & commissioning of unmanaged switch of 10/100/1000 Mbps. The switch shall be mounted on existing rack. The rate shall also include cost of power supply and providing end termination. - 4 port 10/100/1000 Mbps unmanaged Switch
8 port 10/100/1000 Mbps unmanaged Switch
24 port 10/100/1000 Mbps unmanaged Switch
Supply, installation , testing & commissioning of L2 managed POE switch of 10/100/1000 Mbps with 2 Gig SFP. and 2 dual-purpose 10/100/1000 or SFP & power of 15.0W on each Ethernet port. The equipment provides EEE(IEEE 802.3az) and AHM(advanced hibernation management ) The switch shall be mounted on existing rack. The rate shall also include cost of power supply and providing end termination. 48 port 10/100/1000 Mbps POE Switch
12 port 10/100/1000 Mbps POE Switch
Supply and fixing of jack panel with CAT-6 I/O mounted on existing rack with all necessary fixing accessories. The rate shall include cost of ferrule, numbering, stickering & necessary fixing accessories as required -4 port jack panel
8 port jack panel
12 port jack panel
24 port jack panel
Supply, installation , testing & commissioning of 600mm width, 500mm depth wall mounted, closed rack with 1 PDU 1 tray1 cable manager and all necessary fixing accessories as required. -9 U rack
6 U rack
Supply, installation, testing and commissioning of floor mounted 32 U 800/ 1200 mm Network rack with front & rear perforated double doors 2*vertical pdu's, vertical & horizontal cable management including power supply, fans, cable manager and all necessary fixing accessories as required.
Supply, installation, testing and commissioning of network video recorder Supporting up to following Camera Streams with 8TB HDD , shall support windows platform, warning system alerts for fan fault, HDD temp, No HDD detected, HDD full, MPEG4 Compression / decompression with configurable video quality, Network Health and Event Monitoring Support Through Simple Network Management Protocol (SNMP) and New Digital Sentry System Information (DSSI) Utility TCP/IP ready for remote monitoring, data should be achieved to USB drive, Alarm and motion activated recording, 2 Gigabit Ethernet RJ-45 (1000Base-T) interface, the rate shall include monitoring Software, 2 user liscence, camera license,and HDD. Vendor to quote all necessary components as required to complete the system -16 IP Camera Streams
32 IP Camera Streams
Installation, testing and commissioning of existing camera
Supply, installation, testing and commissioning of outdoor/Indoor 2.0MP IP IR Minidome, WDR, 3mm fixed lens Color dome Camera, 1/3" CMOS, H.264/MJPEG High-profile, dual Stream support, True Day & Night (TDN) with , Wide Dynamic Range (WDR), Open Network Video Interface Forum (ONVIF) Profile S & G - TF card support (128 GB), IP66 & IK 10 Rating, Power Over Ethernet (POE), IR distance upto 30 Meter depending on scene reflectance.
Supply, installation, testing and commissioning of outdoor/Indoor 2.0MP IP IR WDR, 3.6mm fixed lens Color Bullet Camera, 1/3" CMOS, H.264/MJPEG High-profile, dual Stream support, True Day & Night (TDN) with , Wide Dynamic Range (WDR), Open Network Video Interface Forum (ONVIF) Profile S & G - TF card support (128 GB), IP66 & IK 10 Rating, Power Over Ethernet (POE), IR distance upto 30 Meter depending on scene reflectance.
Supply, drawing and connecting of cat-6, UTP cable in existing conduit. (Data + CCTV)
Supply, installation, testing and commissioning of Manual Call Point with indication, Plug in wiring Terminals.
Supply, installation of loop powered Hooter 24 v, 100 db
Supply, installation of Power supply unit for hooter
Supply and drawing of 2 core 1.5 Sqmm multistrand FRLS copper wire in existing conduit
Supply, installation, testing & commissioning of PA console panel. The panel can be used as a stand-alone system with up to 4 zones with built-in 240 W power amplifier for emergency call channel and BGM, with contact trigger inputs for business and emergency (EMG) calls. Up to 255 messages can be stored in the internal flash ROM, with automatic limiter Frequency Response 60 Hz – 18 kHz (+1/-3 dB, @ -10 dB ref. rated output)
Supply, installation, testing & commissioning of 480W power amplifier with all the essential functionality for compliance with the IEC 60849 standard, including full system supervision, loudspeaker line impedance. The messages can be merged to allow even more flexible use of pre-recorded announcements and evacuation messages.
Supply, installation, testing and commissioning of 6W, recess/ ceiling mounted speakers. The rate shall include cost of mounting accessories so as to mount the speaker .
Supply, installation, testing and commissioning of 10W, wall mounted speakers. The rate shall include cost of mounting accessories so as to mount the speaker on wall
Supply, installation, testing and commissioning of volume control unit for speakers.
Supply and drawing of 1.5 Sqmm 2 core multistrand copper speaker cable in existing conduit with all necessary accessories.
Supply, Installation, Testing and commission of Single phase input single phase output 600VA transformer less, MOSFET based UPS with built in battery and shall provide back up for minimum 10min. The rate shall include all necessary accessories as required.
DG SUBSTATION WORKS
Design, manufacture, supply, erection, testing & commissioning of 3 phase, 4 wire, 415V, 50 Hz, 125.0 kVA at 0.8 p.f, 1500 rpm, Diesel Generator with single contactor AMF panel with self exciting alternator with suitable size of flexible coupling, water cooled engine mounted with radiator, built in 100 ltr. day tank, residential silencer with Al.cladding, 12 volts, battery, with leads and all other accerssories as specified in the specification including providing common base plate, anti vibration mounting pads (8 Nos.dunlop make), cable end termination, adopter box, foundation bolts, nuts etc., as required. The engine shall be of Cummins make and alternator shall be stamford / equivalent as per specification. The DG set shall be supplied with integral accoustic enclosere complying with Central pollution control board norms/requirements. (CPCB-2)
Design, manufacture, supply, erection,testing & commissioning of 3 phase, 4 wire, 415V, 50 Hz, 35.0 kVA at 0.8 p.f, 1500 rpm, Diesel Generator with single contactor AMF panel with alternator with suitable size of flexible coupling, water cooled engine mounted with radiator, built in 100 ltr. day tank, residential silencer with Al.cladding, 12 volts, battery, with leads and all other accerssories as specified in the specification including providing common base plate, anti vibration mounting pads (8 Nos.dunlop make), cable end termination, adopter box, foundation bolts, nuts etc., as required. The engine shall be of Cummins make and alternator shall be stamford / equivalent as per specification. The DG set shall be supplied with integral accoustic enclosere complying with Central pollution control board norms/requirements. (CPCB-2)
Supply, erection, testing and commissioning of exhaust piping with flexible connections, thermal insulated rockwool lagging with chicken mesh and alluminium sheet wrapping over the exhaust pipes and silencer inside the generator room and with two coats of anti-corrosive primer coating and two coats of heat resistant paint for exposed piping outside the building. The exhaust pipe shall be taken minimum 3 mtr. above the height of the building. The rate shall also include cost of necessary supports, steel brackets, scaffolding etc., all complete as required.
100 mm dia, M.S. pipe with rockwool lagging and aluminium sheet wrapping.
75 mm dia, M.S. pipe with rockwool lagging and aluminium sheet wrapping.
Supply and erection of structural support for exhaust pipe using necessary MS frame work. The sructural support shall be made out of MS frame work using adequate size MS angles. (The vendor shall visit site and quantify the steel requirement and submit the quote along with the GA drgs.
UPS WORKS
Supply, installation, testing and commissioning of three phase input to single phase output 1 x 10.0 kVA, ONLINE, UPS.
Supply, installation, testing and commissioning of SMF batteries for 1 x 10.0 kVA, ONLINE, UPS with 15 min back up. The rate shall include cost of battery, battery rack, cables and necessary accessories as required
Add 12 % GST (in Basic Rate must fill 12)
Add 1% Labour Cess (in Basic Rate must fill 1)
Acme Construction Company
M/S ASHOK MANDAL
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.03 MB
BOQ_57692.xls
BOQ • 0.52 MB
SBD-45.pdf
Tender Documents • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .