Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹98.6 L
EMD Value
₹2.0 L
Closing Date
9 Feb 2026, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
AGC GSU
15 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V=Advertised value of the tender in crores of Rupees, N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure- VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.(Note: No other document than specified above shall be considered valid for evaluating this eligibility criteria).In case of non-submission of above documents, offer may be summarily rejected.
a ) The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii) One similar work costing not less than the amount equal to 60% of advertised value of the tender. (b) (1) In case of tenders for composite works (e.g. works involving more than one distinct component, such as Civil Engineering works, S&T works, Electrical works, OHE works etc. and in the case of major bridges - substrcture,superstructure etc.), tenderer must have successfully completed or substantially completed any one of the following categories of work during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than the amount equal to30% of advertised value of each component of tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of each component of tender, or (iii) similar work each costing not less than the amount equal to 60% of advertised value of each component of tender. Note for b(1) Separate completed works of minimum required values shall also be considered for fulfillment of technical eligibility criteria for different components. (b) (2)In such cases, what constitutes a component in a composite work shall be clearly pre-defined with estimated tender cost of it, as part of the tender documents without any ambiguity. (b) (3) To evaluate the technical eligibility of tenderer, only components of work as stipulated in tender documents for evaluation of technical eligibility, shall be considered. The scope of work covered in other remaining components shall be either executed by tenderer himself if he has work experience as mentioned in clause 7 of the Standard General Conditions of Contractor through subcontractor fulfilling the requirements as per clause 7 of the Standard General Conditions of Contract or jointly i.e., partly himself and remaining through subcontractor, with prior approval of Chief Engineer in writing. However, if required in tender documents by way of Special Conditions, a formal agreement duly notarised, legally enforceable in the court of law, shall be executed by the main contractor with the subcontractor for the component(s) of work proposed to be executed by the subcontractor(s), and shall be submitted along with the offer for considering subletting of that scope of work towards fulfilment of technical eligibility. Such subcontractor must fulfill technical eligibility criteria as follows: The subcontractor shall have successfully completed at least one work similar to work proposed for subcontract, costing not less than 35% value of work to be subletted, in last 5 years, ending last day of month previous to the one in which tender is invited through a works contract.
In case after award of contract or during execution of work it becomes necessary for contractor to change subcontractor, the same shall be done with subcontractor(s) fulfilling the requirements as per clause 7 of the Standard General Conditions of Contract, with prior approval of Chief Engineer in writing. Note for Item 10.1: Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organisation, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate.(Note:In case of non-submission of above documents, offer may be summarily rejected).
Definition of Similar Work :- Any signalling work involving design, installation, testing, commissioning of EI or alteration of EI.
49 conditions · 6 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Documents to be submitted along with the tender.
Please submit your bank details i.e. Name of the Bank along with Bank Branch Code, Account Number, IFSC Code, and PAN Number. (Format attached)
The tenderer shall clearly specify whether the tender is submitted on his own (Proprietary Firm) or on behalf of a Partnership Firm / Company / Joint Venture (JV) / Registered Society / Registered Trust / Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) etc. The tenderer(s) shall enclose the attested copies of the constitution of their concern, and copy of PAN Card along with their tender. Tender Documents in such cases are to be signed by such persons as may be legally competent to sign them on behalf of the firm, company, association, trust or society, as the case may be. (Note: In case of non-submission of above documents, offer may be summarily rejected).
The tenderer whether sole proprietor / a company or a partnership firm / joint venture (JV) /registered society / registered trust / HUF / LLP etc if they want to act through agent or individual partner(s), should submit along with the tender, a copy of power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he/they be partner(s) of the firm or any other person, specifically authorizing him/them to sign the tender, submit the tender and further to deal with the Tender/ Contract up to the stage of signing the agreement except in case where such specific person is authorized for above purposes through a provision made in the partnership deed / Memorandum of Understanding / Article of Association /Board resolution, failing which tender shall be summarily rejected. A separate power of 2.2.1 attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he/they be partner(s) of the firm or any other person, shall be submitted after award of work, specifically authorizing him/them to deal with all other contractual activities subsequent to signing ofgreement, if required. Note: A Power of Attorney executed and issued overseas, the document will also have to be legalized by the Indian Embassy and notarized in the jurisdiction where the Power of Attorney is being issued. However, the Power of Attorney provided by Bidders from countries that have signed the Hague Legislation Convention 1961 are not required to be legalized by the Indian Embassy if it carries a conforming Apostille certificate.(Note:In case of non-submission of above documents, offer may be summarily rejected).
The tenderer will give full information ( in annexure-A) as to the date of retirement of such Engineer or gazetted officer from the said service and as to whether permission for taking such contract, or if the ontractor be a partnership firm or an incorporated company, to become a partner or director as the case may be, has been obtained by the tenderer or the Engineer or officer, as the case may be from the President of India or any officer, duly authorized by him in this behalf, shall be clearly stated in writing at the time of submitting the tender,if a tenderer is - i) be a retired Engineer of the gazetted rank or any other gazetted fficer working before his retirement, whether in the executive or administrative capacity or whether holding a pensionable post or not, in the Engineering or any other department of any of the railways owned and dministered by the President of India for the time being, OR ii) being partnership firm / joint venture (JV) / registered society / registered trust etc have as one of its partners/members a retired Engineer of the gazetted rank or any other gazetted officer working before his retirement, OR iii) being an incorporated ompany have any such retired Engineer of the gazetted rank or any other gazetted officer working before his retirement as one of its directors AND in case where such Engineer or officer had not retired from overnment service at least 1 year prior to the date of submission of the tender
If a tenderer or Contractor being an individual, have member(s) of his family or in the case of partnership firm/ company / joint venture (JV) / registered society / registered trust etc. one or more of his partner(s)/shareholder(s) or member(s) of the family of partner(s)/shareholder(s) having share of more than 1% in the 2.3.1 tendering entity employed in gazetted capacity in the Engineering or any other department of the railway, then the tenderer at the time of submission of tender, will inform the authority inviting tenders the details of such persons. ( in annexure-A)
An undertaking shall be submitted in form of Annexure-VA is to be given by attorney/authorized signatory/each member of Partnership firm/Joint Venture (JV) / Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) etc. as the case may be. Concealment / wrong information in regard to above shall make the contract liable for determination under Clause 62 of the General Conditions of Contract. Note-1: Annexure VA should be submitted as per explanatory formats which are part of documents uploaded along with the NIT in the name of guidelines for filling of Annexure VA. Note-2: In case of non submission of above certificate, or submission of certificate either not properly filled in, or, in a format other than the prescribed format, shall lead to summarily rejection of your offer.
General Compliance
The accepted rates shall be deemed to include and cover all fees, taxes, duties, royalties, rent etc
Income Tax, Surcharge thereof, Goods & Service Tax (GST Act, 2017) and any other applicable tax shall be recovered from contractor's bill as per rule in force.
Implementation of GST Act, 2017 - Procedure for payment of Contractual bill is given in General Instructions attached in document. Please go through the procedure before submission of the offer.
Please enter the percentage of local content in the materialbeing offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Information regarding staff, Plant & machinery, past experience and ongoing work details.
Please furnish list of plant and Machinery available on hand own and proposed to be inducted own and hired to be given separately for the subject work.
Please furnish list of Works on hand indicating Description of Work, Contract Value, Approximate value of balance work yet to be done and Date of award.
Please furnish list of Works completed in last seven financial years giving Description of Work, Organization for whom executed, approximate value of contract at time of award, Date of award and Date of Completion. Date of actual Start, Actual Completion and Final value of Contract shall also be given
Please furnish list of personal, organization available on hand and proposed to be engaged for the subject work.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
If bid security is submitted in the form of Bank Guarantee, it shall be made in favour of Senior Divisional Finance Manager,North Central Railway, Agra. The format of Bank Guarantee is attached in Annexure VI A. The original Bank Guarantee should be delivered to this office within 5 working days before closing date for submission of bids.
Tenderer (s) should attached the scan documents in support of minimum eligibility criteria along with the tender. No document in support of minimum eligibility criteria will be accepted/entertained after opening of tender.
Security Deposit: The Security Deposit shall be 5% of thecontract value. The Bid Security submitted by the Contractor with his tender will be retained/encashed by the Railways as part of security for the due and faithful fulfillment of the contract by the Contractor. Provided further that, if Contractor submits the Cash or Term Deposit Receipt issued from a Scheduled commercial bank of India or irrevocable Bank Guarantee Bond from a Scheduled commercial bank of India, either towards the Full Security Depositor the Part Security Deposit equal to or more than Bid Security, the Railway shall return the Bid Security, to the Contractor. Balance of Security Deposit may be deposited by the Contractor in cash or Term Deposit Receipt issued from Scheduled commercial bank of India or irrevocable Bank Guarantee bond issued from Scheduled commercial bank of India, or may be recovered at the rate of 6% of the bill amount till the full Security Deposit is recovered. Provided also that in case of defaulting Contractor, the Railway may retain any amount due for payment to the Contractor on the pending "on account bills" so that the amounts so retained (including amount guaranteed through Performance Guarantee) may not exceed 10% of the total value of the contract. The Irrevocable Bank Guarantee submitted towards Security deposit shall be initially valid up to the stipulated date of Maintenance period plus 60 days and shall be extended from time to time, depending upon extension of contract granted in terms of Clause 17A and 17B of th Standard General Conditions of Contract. Note: Security Depositde posited in cash by the Contractor or recovered from the running bills of a Contractor or submitted by contractor as Term Deposit Receipt(s) can be refunded/returned to thecontractor, in lieu of irrevocable Bank Guarantee bond issued from scheduled commercial bank of India, to be submitted by him, for an amount equal to or more than the already available Security Deposit, provided however that, in a contract of value less than Rs. 50 Crore, such refund/ return of the already available Security Deposit is permitted up to two times and in a contract of value equal to or more than Rs. 50 Crore, such refund/returnof the already available Security Deposit is permitted up to three times.
Performance Guarantee:- The procedure for obtaining Performance Guarantee is outlined below: (a)The successful bidder shall have to submit a Performance Guarantee (PG) within 21 (Twenty one) days from the date of issue of Letter of Acceptance (LOA). Extension of time for submission of PG beyond 21 (Twenty one) days and upto 60 days from the date of issue of LOA may be given by the Authority who is competent to sign the contract agreement. However, a penal interest of 12% per annum shall be charged for the delay beyond 21(Twenty one) days, i.e. from 22ndday after the date of issue of LOA. Further, if the 60thday happens to be a declared holiday in the concerned office of the Railway, submission of PG can be accepted on the nextworking day. In all other cases, if the Contractor fails to submit the requisite PG even after 60 days from the date of issue of LOA, the contract is liable to be terminated. In case contract is terminated railway shall be entitled to forfeit Bid Security and other dues payable to the contractor against that particular contract, subject to maximu of PG amount. In case a tenderer has not submitted Bid Security on the strength of their registration as a Startup recognized by Department of Industrial Policy and Promotion (DIPP) under Ministry of Commerce and Industry, DIPP shall be informed to this effect. The failed Contractor shall be debarred from participating in re-tender for that work
The Tenderers having more than 20 labour, is required to obtain the labour license from the licensing Officer under Provision of Contract Labour (Regulation and Abolition) Act 1970 read with Contract Labour (Regulation and Abolition) Central Rules 1970. They should obtain a proper and valid labour license for the concerned work from the concerned Asstt. Labour Commissioner or licensing officer of the area and the photo copy of the labour license must be submitted to Railway for records . Failure to do so will attract legal action against the tenderer.
In case any contradiction between general condition of contract & special conditions of contract will prevail over general conditions of contract.
If the tenderer(s) deliberately gives / give wrong information inhis/their tender or creates/create circumstances for the acceptance of his/their tender, the Railway reserves the right to reject such tender at any stage.
All Rules of NIT & Post LOA shall be governed by GCC & tenderer agree to adhere to it without any dispute.
Contractor will clear/clean the work site after completion of the work, to the satisfaction of site engineer.
All false work, staging etc. should be so erected, clamped and secured that these should not infringe / moving dimension and obstruct the railway traffic.
In terms of clause 26A.3 of GCC, the Contractor shall deployatleast one Diploma Holder Engineers at site during the execution of work.
Special Conditions of contract for mandatory updation of Labour Data on Railway's Srakimkalyan Portal by Contract. Clause 54 & 55 of Indian Railway General Conditions of Contract deals with Wages to labour and action in case of default of contractor to payment of wages. In order to increase transparency in payment of Contract Labour wages and other payments, a web based application has been developed and hosted on websit www.shramikkalya. .indianrailway.gov.in. All contractors are required to upload details of their LoAs, engaged workmen, wage payment details, PF/ESI details, bonus details etc., on monthly basis. This details so uploaded shall be available in public domain. In order to ensure prompt and proper uploading of details related to LoAs, engaged workmen, wage & other payment details. The special condition is as under:
A. Contactor is to abide by the provisions of Payment of Wages act & Minimum Wages act in terms of clause 54 and 55 of Indian Railway General Condition of Contract. In order to ensure the same, an application has been developed and hosted on website 'www.shramikkalyan.indianrailways.gov.in'. Contractor shall register his firm/company etc. and upload requisite details of labour and their payment in this portal. These details shall be available in public domain. The Registration/ updation of Portal shall be done as under: (a) Contractor shall apply for onetime registration of his company/firm etc. in the Shramikkalyan portal with requisite details subsequent to issue of Letter of Acceptance. Engineer shall approve the contractor's registration on the portal within 7 days of receipt of such request. (b)Contractor once approved by any Engineer, can create password with login ID (PAN No.) for subsequent use of portal for all LoAs issued in his favour. (c) The contractor once registered on the portal, shall provide details of his Letter of Acceptances (LoA)/Contract Agreement on shramikkalyan portal within 15 days of issue of any LoA for approval of concerned engineer. Engineer shall update (if required and approve the details of LoA filled by contractor within 7 days of receipt of such request.(d) After approval of LoA by Engineer,contractor shall fill the salient details of contract labours engaged in the contract and ensure updating of each wage payment to them on shramikkalyan portal on monthly basis. (e) It shall be mandatory upon the contractor to ensure correct and prompt uploading of all salient details of engaged contractual labour & payments made thereof after each wage period.
B. While processing payment of any 'On Account bill' or 'Final bill' or release of 'Advances' or 'Performance Guarantee/Security deposit', contractor shall submit a certificate to the Engineer of Engineer's representatives that " I have 12.1.1 uploaded the correct details of contract labours engaged in connection with this contract and payment made to them during the wage period in Railway's Shramik kalyan portal at 'www.shramikkalyan.indianrailways.gov.in' till_____Month,_______ year."
Old GCC has been changed and replaced with new General Conditions of Contract-2022, which has been added in tender document. Please go through this new General Condition of Contract-2022 before bidding. In case of any discrepancy, contradiction with regard to GCC (except special condition of contract) in that case GCC- 2022 will be applicable.
S&T works in connection with Provision of longer loop line at Rundhi station in Mathura-Palwal section for running of Python trains.
AGRA-ST-GS-2026-01~NCR
AGRA-ST-GS-2026-01
Open
Works - General
12 Months
Agra, Uttar Pradesh
₹0
₹2.0 L
9 Feb 2026
15 Jan 2026
26 Jan 2026
182 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 98,55,635.14 | ||
| — | 4000.00 | — | — | ||
| Excavation of cable trench as per cable route plan, 1.2 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr. wide at bottom as per RDSO sketch No. SDO/CABLE LAYING/003, issued vide RDSO document no. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014 or latest, alongside the track in normal (all type) soil/strata, conforming to distances as per cable route plan and refilling and ramming of loose soil. This work includes clearing of route from bushes etc, covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately before covering by bricks. The work shall be done as per the extant practice on North Central Railway and instructions of Railway Engineer at site. In case 1.2m depth of trench is not achievable due to site conditions, specific approval JAG/SAG officer will be required for each site where trench depth of 1.2 m is not possible, only after appproval of JAG/SG officer proportionate payment can be done. | — | — | — | 2,58,760 | |
| Laying of S&T Cables of various cores/ pairs/ quads in trenches/ GI pipes/ RCC pipes/ DWC pipes etc. as per the site requirement and as per approved cable route plan. This also includes laying of cables in track crossings & road crossings.(Cables will be meggered before and after its laying by contractor under supervision of Railway Representative and he will submit the meggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes. | — | — | — | 2,32,560 | |
| — | 5.00 | — | — | ||
| Supply of thermo shrink jointing kit as per RDSO Specn.No. IRS: TC 77-2012 (Rev.3.0) with (Amdt.-1 to 3) or latest, suitable for 6 Quad/jelly filled cables for straight through/derivation joints. It includes supply of all the accessories, without transformer. (Inspection by RDSO) | — | — | — | 16,805.75 | |
| — | 5.00 | — | — | ||
| Installation of thermo shrink jointing kit as per RDSO Specn.No. IRS: TC 77-2012 (Rev.3.0) with (Amdt.-1 to 3) or latest, suitable for 6 Quad/jelly filled cables for straight through/derivation joints. It includes supply of all the accessories, without transformer | — | — | — | 8,566.9 | |
| — | 2.00 | — | — | ||
| Supply of Apparatus Case/Location Box Half as per RDSO drg. no. RDSO/S-11507 or latest, with 'E' type lock and key ward no. 42, . The key and handle should be supplied at the rate of one no. per four Apparatus cases. The 'E' type key lock is as per RDSO drg. no.SA 3376/M or latest and Key is as per Drg. No. 3377/M or latest. Note: This item includes the supply of 2 Nos E Type Lock fitted on both doors, along with two Keys. (Inspection by consignee). | — | — | — | 39,809.38 | |
| — | 2.00 | — | — | ||
| Excavation, casting, curing of foundation and Installation and Erection of Apparatus case Half (App. Case as per RDSO drg. no. RDSO/S-11507 or latest) with contractor's own frame, cement and other material in the ratio 1:3:6.'E' type lock to be supplied and installed with App. case.This includes filling of location foundations with river bed sand and plastering on top with a mixture of 1:4 of cement and sand. It covers fixing of lamp holder , switch and lamp etc. in Apparatus Case. | — | — | — | 20,648.36 | |
| — | 5.00 | — | — | ||
| Supply of Apparatus Case/Location Box Full as per RDSO drg. no. RDSO/S-11500 or latest, with 'E' type lock and key ward no. 42, . The key and handle should be supplied at the rate of one no. per four Apparatus cases. The 'E' type key lock is as per RDSO Spec. IRS;S-30/64 or latest, RDSO drg. no.SA 3376/M or latest and Key is as per Drg. No. 3377/M or latest. Note: This item includes the supply of 2 Nos E Type Lock fitted on both doors, along with two Keys. (Inspection by consignee) | — | — | — | 1,37,499.05 | |
| — | 5.00 | — | — | ||
| Excavation, casting, curing of foundation and Installation and Erection of Apparatus case Full (App. Case as per RDSO drg. no. RDSO/S-11500 or latest) with contractor's own frame, cement and other material in the ratio 1:3:6. 'E' type lock to be supplied and installed with App. case.This includes filling of location foundations with river bed sand and plastering on top with a mixture of 1:4 of cement and sand. It covers fixing of lamp holder , switch and lamp etc. in Apparatus Case. | — | — | — | 61,361.1 | |
| — | 5.00 | — | — | ||
| Fabrication and fixing of phenolic laminated sheet of grade P3, minimum 10 mm thick,as per Apparatus case diagram/plan, in location box by providing all fixtures like ARA/Disconnect terminals, fuse blocks, fuses, relays on square bars etc. including fixing of PVC coated string rods at the back side for cable support with contractor's own material like iron angle, nuts, bolts etc. The iron angle for fixing shall be minimum 3 mm thick. This also includes fixing of teak wood shelf minimum 25 mm thick for holding track circuit equipments. The work shall be done as per instructions of Rly engineer at site. (Apparatus case Full) | — | — | — | 22,382.2 | |
| — | 7.00 | — | — | ||
| Supply of Phenolic laminated Sheet, resin bonded, grade P3 in standard size of 1220 X 1220 x 10 mm as per spec. No IS 2036 of 1995 or latest. Test report of manufacture to be supplied. (Inspection by consignee) | — | — | — | 40,789.91 | |
| — | 1300.00 | — | — | ||
| Supply of Disconnect Terminal block for four conductors with screwing cage/clamp type, sliding switch disconnect, as per RDSO spec. RDSO/SPN/189/2004 Ver. 3.0 or latest, for each conductor size up to 2.5 sq. mm, equivalent of M6 terminals. Each terminal block equipped with two markers, on top and bottom, an end plate, two end clamps and adequate lenght of rails for fitting terminal blocks. (Inspection by RDSO) | — | — | — | 2,50,536 | |
| — | 500.00 | — | — | ||
| Supply of ARA terminal block, made of PBT, as per RDSO spec. No. IRS: S-75/2006 (Rev.2) or latest and as per Drawing. No. SA- 23741A (Alt.-4) or latest. (Inspection by RDSO) | — | — | — | 58,505 | |
| — | 1800.00 | — | — | ||
| Fixing of ARA(M-6) Terminals /Screw less connectors / modular disconnect terminal blocks and fuse blocks on phenolic laminated sheets and fixing by stainless steel/brass nuts & bolts. This includes provision of two additional holes on the board on either side for cable conductor entry. The work shall be carried out a per instructions of railway Engineer incharge.(Supply of all above terminals has been covered separately). | — | — | — | 31,734 | |
| — | 10.00 | — | — | ||
| Supply and installation of earth electrode as per standard practice and as per NCR Drawing no. S&T/CONST/6.4/97. It includes supply of GI pipe of 3m length. It includes connecting the earth electrode to the equipments which are required to be earthed including digging of earth pit 3 mtr deep and fixing earth electrode pipe, casting of cement concrete enclosure with cover (cover as per drawing no. S&T/CONST/6.3/97. It includes installation of 7 strand GI wires as earth lead wires, supported on MS flat size 5mm x 40 mm, soldering and nut bolt both, one end of both earth lead wire and MS flat to earth electrode and other end to Location boxes, block equipments, power equipments, cable sheath, signals etc. as per site requirement and as per instructions given by engineer incharge. (Inspection by consignee) | — | — | — | 33,535.4 | |
| — | 1.00 | — | — | ||
| Supply of basic material to construct unit maintenance free earth as per RDSO Specs. No RDSO/SPN/197 Ver. 1.0 or latest to achieve a resistance less than 1 ohm. It consist of following: (a) Copper bonded steel electrode of minimum 3.0 m long, minimum 17.0 mm dia with copper bonding thickness of minimum 250 microns and UL listed and marked = 1 no. (b) Earth enhancement material supplied in sealed bags of minimum 10 kg = 3 nos. (c) Copper strip of 150x25x6 mm, to terminate earth rod = 1 no. (d) Copper strip of 300x25x6 mm (MEEB) = 1 no. (e) Copper strip of 150x25x6mm (SEEB) = 1 no. (ii) Supply of 35 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting main earth electrode to MEEB in the equipment room in duplicate.(minimum 10 meter) (iii) Supply of 16 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting MEEB to SEEB and SPD to MEEB (minimum 10 meter ) (iv) Supply of 10 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting various equipments to SEEB (v) Supply of copper lug sleeve for 3/16 cable (Inspection by RDSO) | — | — | — | 18,042.52 | |
| — | 1.00 | — | — | ||
| Installation of Unit Maintenance Free Earth to achieve a resistance less than 1 ohm as supplied under item no. 13002 of Chapter 13 of SOR. It includes (i) Digging the earth to the required depth. (ii) Insertion of electrode. (iii) Filling of earth enhancing compound (Approx.30 Kg) (iv) Provision of exothermic weld connections to copper tape of 25 mm x 6 mm x 150 mm to the earth electrodes. All material tools and features required for weld will be arranged by contractor. (v) This also includes CC cover 1.5 ft x 1.5 ft. 1 ft wall thickness 2 inch with cover 3 inch thickness. Cables 35 Sq mm/ 16 Sq mm/10 sq mm for connecting earth to busbar, busbar to busbar and busbars to various equipments. Earth electrode of 17.20 mm dia and 3.00 meter long high tensile low carbon steel circular rods molecularly bonded with copper and outer surface (minimum copper bonding thickness of 250 micrones to made requirement of under writer's laboratories (UL) 467-2007 or latest. Copper strips of 150 mm x 25 mm x 6 mm to be welded with each earth electrode, copper strips of 300 mm x 25 mm x 6 mm for main equip- potential busbar, copper strips of 150 mm x 25 mm x 6 mm sub equip-potential busbar in relay room, power room and panel room. GI strip 25 mm x 2 mm for ring formation of earth pits Earth enhancement material in bags for each Earth Electrode. Inspection chamber of site 300 mm x 300 mm x 300 mm (Inside dimension) of approximate 50 mm thick with pulling hooks to cover the earth pits. Note: The installation of this item shall be carried out by the contractor as per RDSO Specn.No.RDSO/SPN/ 197 Ver 1.0 or latest. Typical RDSO approved drawings referred in the RDSO specification document are : (i) SDO/RDSO/E&B/001 for typical installation of Earth, (ii) SDO/RDSO/E&B/002 for typical bondong and earthing connections, (iii) SDO/RDSO/E&B/003 for typical arrangement for earth resistance measurements. | — | — | — | 7,193.17 | |
| — | 20.00 | — | — | ||
| Supply of Track Lead Junction Box(TLJB), 4 way, 250 mm x 255 mm x120 mm made from FRP, as per Drg.No. 20101/M(IRS) or latest, including brass bolts and hylam board sheet with terminals etc. The FRP material shall be as per RDSO spec. RDSO/SPN/151/1997 or latest.The technical specifications are as follows: (a) TLJB complete with cover to be in black/red/grey with all the holes required for mounting on FRP stump (vertical two for each FRP angle) HDPE pipe , cable etc. (b) Each TLJB shall have two bakellite terminal block fitted horizontally, each bakellite terminal block shall have two nickel chrome plate with brass terminal. Alongwith each TLJB , nickel chrome plated brass links(two nos.of adequate strength for vertical linking of the terminals to be supplied. (c) HDPE pipe alongwith two nuts for fixing on the TLJB hole . (d) The FRP stump for mounting the TLJB (Inspection by consignee) | — | — | — | 1,09,300.8 | |
| — | 15.00 | — | — | ||
| Erection, fitting and Rail connection of track lead junction box with contractor's fixing material including angle of size 40 x 40 x5 mm1200mm length. This will include drilling of holes for side connection along with concrete base foundation of size 1x1x1 feet.Tail cable shall be laid in HDPE pipe from bottom of foundation up to TLJB. The work shall be done as per instruction of Rly. Engineer at site. | — | — | — | 13,091.1 | |
| — | 8.00 | — | — | ||
| Multi section Digital Axle Counter (MSDAC) supply,design, installation, testing,and commissioning of multi section digital axle counter (MSDAC)complete system as per RDSO Specification No.RDSO/SPN/176/2013 version 3 with Latest amendments or latest.Suitable for commissioning of yard/Auto section/dual detection (DCTC/AFTC withMSDAC). MSDAC should have facility to reset track sections.Design of axle counter circuit indoor installation testing and commissioning of multi section digital axle counter (per unit),supply of essential 10% spares covering all types of cards wheel sensors for MSDAC . Supply of Diagnostic system for Remote diagnostics Tool set for wheel sensor mounting and maintenance of MSDAC consisting of torque wrench ,ratchet, testing plate,measuring tape,screw driver ,gloves and multimeter fluke 115(1 Nos.per 14 DP).'' '' NOTE-1 :1. If any housing is required to keep outdoor equipment , it has to be supplied with the equipment with no extra cost. 2. maintanance free earthing (supply and installation) for track device/mushroom housing etc to be done by the contractor if required by system design . No extra cost/payment will be made by Railways. 3. Automatic resetting facilities through hardware/software for auto resetting to be 8 provided by contractor by his own materials for this no extra cost/payment will be made by Railways. 4. MSDAC system networking to be done with central control room .Required hardware PC/network equipment to be provided by the contractor ,no extra cost/payment will be made for this by Railway. E1 Channel/media will be provided by railway for this purpose from nearest Railway station. 5. All other Hardware like TPR , Extra card to make dual DP,Modem,ethernet switches etc if required for commissioning and final track section pick up will be supplied by contractor ,no extra payment will be made by this Railway. 6 Separate evalutor for UP and Down line to be provided at station/RH as decided by Railway site engineer. For the communication between evalutor to evalutor (RH to Station)Quad/OFC Link (dark fiber) will be provided by Railway . Any other Networking equipment if required will be supplied by contractor at no extra cost. 7. Manual resetting through reset box at station to be provided as per requirment.Note: MSDAC should be compatible with existing MSDAC installed at station (Inspection by RDSO) | — | — | — | 25,40,532.96 | |
| — | 6.00 | — | — | ||
| Provision & running of one MUV to the sites of work as per requirement and direction of Engineer In charge along with Driver for Transportation of less heavy materials & manpower. The rates includes all taxes, license fee, road permit,toll tax, driver wages, fuel, repair and maintenance cost etc complete in all respects. (2500 Km per month) | — | — | — | 1,70,898.1 | |
| — | 1.00 | — | — | ||
| Preparation of SIP, RCT, Mini-diagram (Red & Green), documents related to TSAA approval ,documents related to CRS application, cable route plan of station & adjacent block section, cable corage plan, location diagram & particulars for all the locations of station and block section, CT rack particulars and cable termination diagram, SWR, SWRD, Cable meggering report/insulation test record, earth resistance particulars and earthing diagram (also to be painted on the wall), Power supply distribution/wiring diagram, Relay rack particulars, traction bonding diagram, track insulation & bonding diagram, maintenance format for all S&T gears as instructed by railway representative, fuse analysis chart, datalogger validation chart, contact analysis chart, equipment layout plan & any other drawing/particulars required for PI/EI as per SEM & technical specifications applicable for circuit designing as per NCR practice. (Inspection by Consignee). Preparation of all these tentative documents in paper for railway approval and submission thereafter in tracing as per railway practice. Submission of completion documents in a set of 06nos in hard copy & soft copy of the same in pen drive (in editable format). | — | — | — | 29,388.83 | |
| — | 2.00 | — | — | ||
| Supply of Non Metallic (FRP) colour light signal housing multi unit type for railway signalling suitable for RE area FOUR Aspects, complete without lenses, lamps and signal transformer as per RDSO Drg. No. SA 23001 A/M (Adv.) and as per RDSO spec. No. RDSO/SPN/194/2006 (Rev 2.0) or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or latest. (Inspection by consignee) | — | — | — | 84,461.66 | |
| — | 3.00 | — | — | ||
| Erection of CLS Post with base and signal unit on top or on Offset Bracket including erection of auxiliary signals like calling on, shunt signal if any. It includes fixing of all LEDs and wiring of complete signal including route and auxilliary signals, if any. It includes fixing of front and back staging, ladder and guards, signal name plates / boards, with contractor's own brackets and fixing materials. The work shall be done as per instructions of Rly engineer at site. It also includes provision & fixing of maintenance platform as per design given by Engineer -In-Charge at site. The Item includes cutting of Signal post if required by Site In charge. | — | — | — | 17,636.22 | |
| — | 300.00 | — | — | ||
| Horizontal Boring/Manual moling without damage to surface road /track for laying/isertion of DWC/GI/HDPE pipe. The bore shall be done at the depth of minimum 1400 mm from the ground level. The ground level shall be considered ignoring the bank height of the bank of the road. Note:- DWC/HDPE/GI Pipe Supply is not covered under this item. Contactor shall provide all material required for work and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable. Payment of boring shall be made only after DWC/HDPE/GI pipe is laid in the bore. | — | — | — | 3,08,712 | |
| — | 100.00 | — | — | ||
| Supply of Double Walled Corrugated (DWC) Pipe/duct with associated collars etc. as per RDSO Specification No. RDSO/SPN/204/2011 or latest anti-rodent & anti-oxidant and non flame propagating type in 6 meters straight length and of size 120 mm outer dia,& 103.5 mm inner dia. (The manufacturers, suppliers must produce valid IS license and should be certified under ISO 9000 and shall submit copy of certificate). One coupler with suitable rubber O-ring should be supplied with every 6m of pipe length. DWC pipe shall be marked at every 1 mtr length in such a way that manufacturer's name, vendor name and year of manufacture can be easily identified. (Inspection by consignee) | — | — | — | 60,687 | |
| — | 1.00 | — | — | ||
| Modification/Alteration in existing EI (Electronic Interlocking) as per latest RDSO guidelines & TAN. It includes: Design and modification in existing Interface,Interlocking circuits and logic of EI system including modification in the VDU (Video Display Unit)/ LCP (Local Control panel), CCIP (Control cum Indication Panel) if any, Maintenance terminal (MTPC), Data Logger, Relay rack wiring etc. The complete work should comply with the latest RDSO specifications, guidelines and as per approved SIP & circuit diagrams. All the material (Interface cards/ relays/ wiring material/ connectors/ fuses /communication devices etc.) shall be provided by the contractor. The work includes the supply of modified Selection table, Interface Circuits, VDU/LCP, CCIP diagram if any etc. to suit the modified SIP. It also includes the carrying out of FAT, SAT or two rounds FAT (as applicable) jointly with Railways and satisfactory commissioning. All plans/drawings/circuits etc. should be prepared on Auto CAD. Soft copy including Auto CAD copy has to be supplied in pen drive and 06 sets of hard copies also to be supplied as a completion drawing. (B) Alteration involving modification from 11 up to 20 routes. (Per alteration=Station) | — | — | — | 25,64,630 | |
| — | 7.00 | — | — | ||
| Modification/Alteration in existing EI (Electronic Interlocking) as per latest RDSO guidelines & TAN. It includes: Design and modification in existing Interface,Interlocking circuits and logic of EI system including modification in the VDU (Video Display Unit)/ LCP (Local Control panel), CCIP (Control cum Indication Panel) if any, Maintenance terminal (MTPC), Data Logger, Relay rack wiring etc. The complete work should comply with the latest RDSO specifications, guidelines and as per approved SIP & circuit diagrams. All the material (Interface cards/ relays/ wiring material/ connectors/ fuses /communication devices etc.) shall be provided by the contractor. The work includes the supply of modified Selection table, Interface Circuits, VDU/LCP, CCIP diagram if any etc. to suit the modified SIP. It also includes the carrying out of FAT, SAT or two rounds FAT (as applicable) jointly with Railways and satisfactory commissioning. All plans/drawings/circuits etc. should be prepared on Auto CAD. Soft copy including Auto CAD copy has to be supplied in pen drive and 06 sets of hard copies also to be supplied as a completion drawing. (C)Alteration involving modification more than 20 routes. Note: 1. Rate upto 20 Routes shall be taken as 01002(B), alteration in routes more than 20 shall covered with this item. 2. This item shall be operated for only below 200 routes stations involving alteration is in less than 50% routes. | — | — | — | 8,97,620.5 | |
| — | 2.00 | — | — | ||
| Supply of Position Light Shunt Signal Unit Complete,Metallic, Independent type, along with base and post, hood, Cover etc as per Drg. No. SA-23840 (Adv.) suitable for LED Signal Lighting Unit.(Supply of LED Unit is not covered in this item) (Inspection by consignee) | — | — | — | 7,853.84 | |
| — | 1.00 | — | — | ||
| Supply of Position Light Shunt Signal Unit Complete, Non-Metallic, made of FRP as per Drg. No. SA-23840 (Adv.) suitable for LED Signal Lighting Unit.(Supply of LED Unit is not covered in this item) (Inspection by consignee) | — | — | — | 14,895.79 | |
| — | 3.00 | — | — | ||
| Supply of Electric Point Machine 143 mm stroke, AC Immunity 160V AC, complete with lock detector and slides for lock detector,Non-trailable,to operate on 110V DC, rotary locking with crank handle universal type as per RDSO Spec. No. IRS:S-24/2002 (Amnd. 1) or latest, RDSO DRG. NO S-10800 (ALT.5) WITH JUNCTION BOX TELESCOPIC. THE MOTOR WILL BE AS PER RDSO SPECN. NO. IRS: S-37/82 (AMND. 3) WITH RDSO DRG. NO. S-10910. This includes supply of Set of tools as per para 20.1 & 20.2 of RDSO SPECN. NO. IRS:S-24/2002 (AMND 1) The following set of tools in a suitable tool box shall be supplied along with every set of eight point machines or less. i). Hand operated square drive socket wrenches of 12.5 mm driving square (short type) as per IS: 7381 for M8, M10, M12 & M18 threads. (One 250 mm long 12.5 mm square extension bar as per IS: 7991 alongwith compatible Tee handle Square drive as per IS: 7975 suitable for above socket wrenches shall also be provided.) ii). Open jaw wrenches (spanners) for M10, M12, M20, M24 & M33 threads as per IS: 2028. iii). Adjustable wrench. iv). Screw driver 300 mm long. 20.2 Junction box and two numbers of telescopic pipes of approved type shall be supplied as an integral part of the point machine. (Inspection by RDSO) | — | — | — | 3,01,207.5 | |
| — | 3.00 | — | — | ||
| Fixing, wiring, testing and commissioning of Electrical Point Machine on the Wooden/PRC sleepers at points as per standard practice and as per section of rails used. Item includes fixing switch extension bracket, providing insulation for switch extension bracket, fixing ground connection, adjusting opening of the switches and adjusting the point machine with crank handle.The item also includes : (i)Complete material for installation like ground-connections, switch extension brackets, point insulation material, I pipes, wiring materials, various fixing nuts & bolts including castle nuts, spring washers (ii) All smithy & fitting works required at site for complete installation. (iii) Installation of gauge tie plate & providing insulation for gauge tie plate (Insulation in William Stretcher Bar will be provided by Railways). (iv) Wiring inside the point machine, insertion and termination of tail cable in point machine and junction boxes / location box /cable hut as per extent practice on NCR and the instruction of Railway Engineer at site. (v) Supply and fixing of bend pipes with welded frame for cable entry to machine (vi) Supply and filling of industrial grade/good quality lubricant/grease/oil for smooth opertion of point machine Note ; The ground connections shall be suitable to the Point Machines as specified by Engineer-in-charge and shall be suitable to the point lay out i.e. 60 Kg. / 52 Kg / 90R as per yard layout. Electrical Point Machine and M-6 / Screw less terminals will be supplied by Railways / covered in Schedule separately. | — | — | — | 43,354.29 | |
| — | 9.00 | — | — | ||
| Supply of stretcher bar insulation complete set consisting of the following:- Plate-T- 10367-1 No., Bush T- 10368- 3 Nos. and washer-T- 10371 -6 Nos. (Inspection by consignee) | — | — | — | 3,433.41 | |
| — | 6.00 | — | — | ||
| Supply of gauge tie plate insulation complete set each set consisting plate T-10372 = 1No., Bush T-10368=3 Nos. and washer - T-10371 = 6 Nos. (Inspection by consignee) | — | — | — | 2,291.64 | |
| — | 3.00 | — | — | ||
| Supply of IRS Type point machine 'D'/'P' bracket insulation complete set consisting of the following:- Plate LH - S-3266-1 No, RH - S-3265-1 No., Plate S-8804- 1 No., Bush - S- 3199 - 4 Nos, Bush S-8813- 2 Nos. (Inspection by consignee) | — | — | — | 1,440.03 | |
| — | 3.00 | — | — | ||
| Fabrication and supply of point rodding (Ground Connection) set for electric point machine (RDSO Type) as per RDSO Drg. No.SA-8800-01, 20-21, 9151-52,9000-01,03-04,9065- 66,9101, as applicable. (Inspection by consignee) | — | — | — | 44,187.81 | |
| — | 3.00 | — | — | ||
| Supply and fixing of GI bend pipe 50 mm dia., 'B'class, for cable entry into Point machine with all accessories. Note: This item to be operated independently for those points where Point machines are functional but GI bend pipe is not provided. For all other new installation of Point machines, item 06002 of the SOR includes the provision of GI bend pipe. (Inspection by consignee) | — | — | — | 9,566.25 | |
| — | 1.00 | — | — | ||
| Supply of Position Light Shunt Signal Unit Complete, Metallic, Post type, along with Offset bracket, Hood, Cover, mounting socket etc as per Drg. No. SA-23840 (Adv.) or latest, suitable for LED Signal Lighting Unit.(Supply of LED Unit is not covered in this item) (Inspection by consignee) | — | — | — | 8,856.29 | |
| — | 2.00 | — | — | ||
| Casting, concreting and curing of foundation for Position Light Shunt Signal as per Drg.No.NR/S&T/Const/2.2/97 using standard size of foundation/galvanized anchor bolts complete, required for erection of shunt signal post. Anchor bolts complete should comply with the RDSO drg. no. SA 116 A/M. Item includes excavation, ramming of CC using vibrator, curing and plastering with 1:4 cement sand mixture. Aggregate cement, sand and holding down bolts, will be supplied by contractor. Any machines and tools, if required for execution of this item, will be arranged/provided by contractor. | — | — | — | 7,337.32 | |
| — | 2.00 | — | — | ||
| Erection of Position Light Shunt signal with Base, Post, Signal unit, complete fixing of LEDs and wiring of full signal. It includes fixing of Number Plates. The work shall be done as per instructions of Rly engineer at site. | — | — | — | 1,902.1 | |
| — | 1.00 | — | — | ||
| Supply of Metallic colour light signal housing multi unit type for railway signaling suitable for RE area TWO Aspects, complete without lenses, lamps and signal transformer as per RDSO DRG. No. SA 23003 A/M (Adv.) and as per RDSO spec. No.IRS:S-26/64 or latest. (Inspection by consignee) | — | — | — | 26,176.53 | |
| — | 1.00 | — | — | ||
| Fixing of Junction type Route Indicator on top of signal post and complete wiring, 1- Way/2-Way/3-Way/4-Way/5-Way/6-Way/theater type. | — | — | — | 1,112 | |
| — | 10.00 | — | — | ||
| Supply of DC Track circuit bond:- length 2 meter in stainless steel (Non Magnetic) Multi stand wire 10 sq mm 2 layer insulation with SS (Non Magnetic) Web pin for fit designing and other side SS (Non Magnetic) Lug. Contractor should get the approval of sample from Railway Engineer before supply. (Inspection by consignee). | — | — | — | 12,509.8 | |
| — | 10.00 | — | — | ||
| Supply of DC Track circuit bond:- length 3 meter in stainless steel (Non Magnetic) Multi stand wire 10 sq mm 2 layer insulation with SS (Non Magnetic) web pin for fit designing and other side SS (Non Magnetic) Lug. Contractor should get the approval of sample from Railway Engineer before supply. (Inspection by consignee). | — | — | — | 17,076.4 | |
| — | 10.00 | — | — | ||
| Supply of DC Track circuit bond:- length 4 meter in stainless steel (Non Magnetic) Multi stand wire 10 sq mm 2 layer insulation with SS (Non Magnetic) web pin for fit designing and other side SS (Non Magnetic) Lug. Contractor should get the approval of sample from Railway Engineer before supply.(Inspection by Consignee) | — | — | — | 23,915.5 | |
| — | 10.00 | — | — | ||
| Supply of DC Track circuit bond:- length 5 meter in stainless steel (Non Magnetic) Multi stand wire 10 sq mm 2 layer insulation with SS (Non Magnetic) web pin for fit designing and other side SS (Non Magnetic) Lug. Contractor should get the approval of sample from Railway Engineer before supply.(Inspection by Consignee) | — | — | — | 28,982.5 | |
| — | 3.00 | — | — | ||
| Installation and commissioning of DC track circuits including drilling of bond holes, supply and fixing of continuity GI wire bonds on rail joints after drilling bond-hole of 7.0/7.2mm dia. wherever required, bond clips, channel pin & making rail connections of lead wires, installation & fixing of track lead junction box on MS angle grouted on concrete and cable taken through DWC Pipe for track feed end, track relay end and BX Jumpers, connections to tail cable, termination of tail cables on TLJB terminals etc., insertion of insulated block joints and also fixing jumper cables as per insulation diagram/track bonding plan, charging & adjustment of track circuit, all activities as per standard practice and technical specifications. This also includes Installation, fixing and wiring of DC track circuits equipments, track battery charger, resistances/chokes, track relays and batteries etc., in apparatus cases, location huts, relay rooms etc., with contractor's wiring material, termination of tail cables. T.C. not involving pt. zone | — | — | — | 29,399.97 | |
| — | 4.00 | — | — | ||
| Installation and commissioning of DC track circuits including drilling of bond holes, supply and fixing of continuity GI wire bonds on rail joints after drilling bond-hole of 7.0/7.2mm dia. wherever required, bond clips, channel pin & making rail connections of lead wires, installation & fixing of track lead junction box on MS angle grouted on concrete and cable taken through DWC Pipe for track feed end, track relay end and BX Jumpers, connections to tail cable, termination of tail cables on TLJB terminals etc., insertion of insulated block joints and also fixing jumper cables as per insulation diagram/track bonding plan, charging & adjustment of track circuit, all activities as per standard practice and technical specifications. This also includes Installation, fixing and wiring of DC track circuits equipments, track battery charger, resistances/chokes, track relays and batteries etc., in apparatus cases, location huts, relay rooms etc., with contractor's wiring material, termination of tail cables. Pt. zone T.C. | — | — | — | 41,815.52 | |
| — | 14.00 | — | — | ||
| Supply of B Type Choke as per RDSO Specn.No.IRS:S-65/83 (Amnd. 3) or latest. (Inspection by RDSO) | — | — | — | 82,727.82 | |
| — | 7.00 | — | — | ||
| Supply of Adjustable Track Feed Resistance 30 Ohms (Disc Type), Phenolic moulded base, as per RDSO Drg. No.SA-20161-66/M or latest. (Inspection by RDSO) | — | — | — | 15,958.46 | |
| — | 7.00 | — | — | ||
| Supply of Track feed Battery Charger as per RDSO Specn. No.IRS: S-89/2013 Ver.1.0 or latest. Charging capacity rating should be suitable for charging 80 AH Battery. (Inspection by RDSO) | — | — | — | 41,303.92 | |
| — | 2.00 | — | — | ||
| Supply of Key Lock Checking Relay (KLCR) working on 24V DC, AC Immunized, metal to metal, with different ward combinations and contact configuration 4F/4B with 2 extra ward plates, RDSO spec no. RDSO/SPN/219/2016 Ver 1.0 with Amendment-1 or latest. (Inspection by RDSO) | — | — | — | 16,046.36 | |
| — | 1.00 | — | — | ||
| Supply and installation of prewired KLCR Box, wooden crank handle lock inside box, with 8 way terminal strips, LEDs of approved type, for fixing of EKT on wooden board inside box form installation KLCRs/EKTs up to 06 no., including supply of all material like board, handle, hinges, glass sheet etc. (Inspection be consignee) | — | — | — | 13,359.12 | |
| — | 300.00 | — | — | ||
| Supply of Cartridge Fuse block, made of PBT, as per RDSO spec. No. IRS: S-75/2006 (Rev.2) or latest and as per Drawing. No. SA- 23748 (Alt.-4) or latest. (Inspection by RDSO) | — | — | — | 73,065 | |
| — | 300.00 | — | — | ||
| Supply of Non deteriorating type, round head type, low voltage cartridge fuse as per Spec No IRS: S -78/2006 with latest amendments, 2A/4A/6A/8A/10A rating capacity. (Inspection by RDSO) | — | — | — | 36,942 | |
| — | 20.00 | — | — | ||
| Q-Series Line Relay (QNA1 Type), AC immunized, 8F/8B, 24 V DC along with plug board (base plate), connectors, retaining clips etc. and conforming to BRS-931A and RDSO Specn.No.IRS: S - 34, S - 23, S - 60 or latest, as applicable. The interlocking code for this unit shall be "ABDGH". (Inspection by RDSO) | — | — | — | 88,784.8 | |
| — | 20.00 | — | — | ||
| Q-Series LED ECR (Universal Type i.e. QECX-61), 4F/4B complete with plug board (base plate), connectors, retaining clips etc. and conforming to BRS:941A STS/E/RELAYS/AC LIT LED SIGNAL/09-2002, Amdt. -1 or latest and RDSO Spec.No.IRS: S - 34, S-23 or latest, as applicable. The interlocking code for this unit shall be "ABDHK". (Inspection by RDSO) | — | — | — | 1,38,347.6 | |
| — | 20.00 | — | — | ||
| Termination of cables and supporting of string rod, with supply and providing identification tags/ferrules/tapes with letters on each cable conductor. As per instruction of site incharge. (Full case) (Per Loc= Per Number) | — | — | — | 6,721.4 | |
| — | 2.00 | — | — | ||
| Termination of cables and supportling of string rod, with supply and providing identification tags/ferrules/tapes with letters on each cable conductor As per instruction of site incharge. (Half case) (Per Loc= Per Number) | — | — | — | 589.06 | |
| — | 2.00 | — | — | ||
| Fixing / Wiring /Alteration/Additional wiring & paralleling of installed (working) indoor and outdoor Relay contacts also after completing the wiring, proper bunching to be done with own bunching material as thread, tag etc by the contractor.(Fixing in location boxes with own material by contractor) | — | — | — | 385.18 | |
| — | 100.00 | — | — | ||
| Lettering and Numbering of all S&T gears like Signals, Loc. Boxes, Pt. Machines, TLJBs, Block joints etc. Each item to be taken as one unit. | — | — | — | 8,361 | |
| — | 24.00 | — | — | ||
| Supply of uncharged Low Maintenance Lead Acid (LMLA) secondary cell, 2V, 80 AH, in dry condition, shelf mounting type, conforming to RDSO Specn.No.IRS:S-88/2004 or latest, with inter cell connectors, nuts and bolts, washers, microporous vent plug, float etc. (Inspection by RDSO) | — | — | — | 76,691.04 | |
| — | 24.00 | — | — | ||
| Charging of Lead Acid Batteries, 2V, 80 AH, with contractors own battery grade sulphuric acid and distilled water with minimum two charge - discharge cycles, installation of charged batteries in groups & their connection & wiring. The work shall be done as per the procedure prescribed by the OEM and extant practice of N.C. Rly and instruction of Engineer-in-charge. Detailed measurements of initial charging shall be recorded jointly by contractor & Rly's site-in- charge. | — | — | — | 6,094.08 | |
| — | 10.00 | — | — | ||
| Q-Series Track Relay (QTA2 Type), AC immunized, 9 Ohms, 2F/1B along with plug board (base plate), connectors, retaining clips etc. and conforming to BRS:939A & 966(Appendix F2) or latest and RDSO Specn.No.IRS: S - 34, S-23, S-60 or latest, as applicable. The interlocking code for this unit shall be "FGHKX". (Inspection by RDSO) | — | — | — | 38,032.5 | |
| — | 10.00 | — | — | ||
| Q-Series Neutral Line Relay (QSPA1 Type), AC immunised, 24V DC,8F/4B along with plug board (base plate), connectors, retaining clips etc. and conforming to BRS-933A and RDSO Specn.No.IRS: S - 34, S-23, S 60 or latest, as applicable. The interlocking code for this unit shall be "ABDEJ". (Inspection by RDSO) | — | — | — | 60,564 | |
| — | 1000.00 | — | — | ||
| Supply of Channel pins, single groove, 7 mm, galvanised, suitable for 4 mm dia bonding wire for Track Circuit rail bonding, as per RDSO spec. IRS: S 17-75. (Inspection by consignee) | — | — | — | 4,550 | |
| — | 3.00 | — | — | ||
| Supply of Colour Light Signal Post, Tubular Mild steel, 4.5 m length, 140 mm Dia, as per RDSO spec. No. IRS: S-6/81 or latest and Supply of cast iron Main signal surface base (As per RDSO Drg. No. 2011/M or latest), with CLS ladder assembly suitable for colour light signal 4.5 m long, as per RDSO Drg. No. SA 23153 and signal front staging complete assembly and complete signal back staging for CLS unit. (Inspection by consignee) | — | — | — | 75,821.04 | |
| — | 1.00 | — | — | ||
| Supply of "A" marker LED signal lighting unit retrofittable in existing CLS housing and compatible with AC LED ECR, (as per spec. RDSO/SPN/153/ 2023 Rev 5.0 or latest). (Inspection by consignee) | — | — | — | 4,604.93 | |
| — | 4.00 | — | — | ||
| Supply, fabrication and fixing of retro-reflective marker/boards/plates as per the following: 'P' marker-Non illuminated as per Drg. no.SA-23456 (Adv), 'AG' marker-Non illuminated as per Drg. no.SA-23459-60 (Adv), 'A' marker - Illuminated as per Drg. no.SA-23461(Adv), 'G' marker - Non illuminated as per Drg. no.SA-23477(Adv) or as applicable and provided by Railways. (Inspection by Consignee). | — | — | — | 3,549.48 | |
| — | 8.00 | — | — | ||
| Supply, fabrication and fixing of Retro-reflective Signal number plates as per NCR Drg. No. TYP/14/0014 dtd 28.11.2014 issued vide NCR letter no. S&T/NCR/DRG/TYP dated 28.11.2014, on signal post with contractor's own material like clamp, U bolts, nuts etc. (Inspection by Consignee). | — | — | — | 5,956 | |
| — | 3.00 | — | — | ||
| Casting, concreting and curing of foundation for Main Signal Post in the ratio of 1:3:6 as per NCR Drg. No. TYP/013/14/SIG FOUND. dtd 12.11.2014 (total 2 sheets of drawing) issued vide NCR letter no. S&T/NCR/DRG/TYP dated 13.11.2014, using standard size of foundation/galvanized anchor bolts complete, required for erection of colour light signal post. Anchor bolts complete should comply with the RDSO Drg. no. SA 116 A/M. Item includes excavation, ramming of CC using vibrator, curing and plastering with 1:4 cement-sand mixture (aggregate will not exceed 3.8 cm). Aggregate, cement, sand and holding down bolts will be supplied by contractor. Any machines & tools, if required for execution of this item, will be arranged/provided by contractor. | — | — | — | 40,518.84 | |
| — | 3.00 | — | — | ||
| Supply of Offset brackets for Main Signal, made of Mild Steel, outer diameter 140 mm (5.5 inch), thickness of pipe 4.5 mm with fixing arrangement on Main Signal post as per Drawing No SA- 23080/Adv. along with fixing U bolts, nut and clamps. (Inspection by Consignee). | — | — | — | 3,619.77 | |
| — | 3.00 | — | — | ||
| Supply of offset brackets for Shunt Signal, made of Mild steel, outer diameter 89 mm (3.5 inch), thickness of pipe 4.5 mm with fixing arrangement on Shunt Signal post as per Drawing No SA- 23080/Adv. along with fixing U bolts, nuts and clamps. (Inspection by Consignee). | — | — | — | 5,693.64 | |
| — | 20.00 | — | — | ||
| Supply of hand cuff lock of Godrej/Navtal or reputed make with key and as approved by site engineer. (Inspection by Consignee). | — | — | — | 9,075.2 | |
| — | 20.00 | — | — | ||
| Cement Concrete of proportion 1:2:4 (Cement: Sand: Stone chips of 20mm nominal size) for miscellaneous items. It includes excavation, ramming of CC by using vibrator, curing and plastering with cement and sand mixture (aggregate will not exceed beyond 3.8 cm). Note: All materials required for foundation are to be supplied by the contractor. | — | — | — | 69,000 | |
| — | 14.00 | — | — | ||
| Shifting of existing full location boxes coming in the alignment of new line. The work includes losing & removal of soil around location boxes by excavating soil around foundation, making of pit for shifting of location box horizontally opposite to railway track up to 0.5 to 1.0 Mtr. This includes losing of existing cable coils without any damage. The excavated soil shall be back filled after shifting of Location Boxes Location box shall be shifted by push method with the help of jacks or by crane by contractors' own expenditure under instructions of engineer in-charge at site. The work may affect train working hence the work shall be done as per margin only or during traffic block only. | — | — | — | 68,179.02 | |
| — | 5.00 | — | — | ||
| Shifting of existing half location boxes coming in the alignment of new line. The work includes losing & removal of soil around location boxes by excavating soil around foundation, making of pit for shifting of location box horizontally opposite to railway This includes losing of existing cable coils without any damage. The excavated soil shall be back filled after shifting of Location Boxes. Location box shall be shifted by push method with the help of jacks or by crane by contractors' own expenditure under instructions of engineer in-charge at site. The work may affect train working hence the work shall be done as per margin only or during traffic block. | — | — | — | 16,898.6 | |
| — | 5.00 | — | — | ||
| Alteration/ Modification in the existing location boxes, fixing of equipments cable cable insertion, termination, wiring, testing and commissioning two coat painting, lettering to suit the circuits as per approved wiring diagrams. This includes filling with sand and plastering the same. | — | — | — | 15,710.95 | |
| — | 100.00 | — | — | ||
| Cross trench for identification of the route of existing signalling and telecom cables. | — | — | — | 29,029 | |
| — | 50.00 | — | — | ||
| Supply of PPTC fuse GP 250-185, UL-94 certification (24 V/ 4 Amp) 110V AC for Track Chargers. Make Fuzetec, Tyco, Raychem, Little fuse or similar. (Inspection by consignee) | — | — | — | 419 | |
| — | 50.00 | — | — | ||
| Excavation of cable trench as per cable route plan, 1.2 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr. wide at bottom as per RDSO sketch No. SDO/CABLE LAYING/003, issued vide RDSO document no. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014 or latest, alongside the track in Rocky soil, conforming to distances as per cable route plan and refilling and ramming of loose soil. This work includes clearing of route from bushes etc., covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately. The work shall be done as per the extant practice on North Central Railway and instructions of Railway Engineer at site. In case 1.2 m depth of trench is not achievable due to site conditions, specific approval of JAG/SG Officer will be required for each site where trench depth of 1.2m is not possible, only after approval of JAG/SG Officer proportionate payment can be done. | — | — | — | 4,459 | |
| — | 50.00 | — | — | ||
| Cutting of all types of platforms/road crossing and trenching and excavation to a width and depth of 300 mm x 300 mm, laying of DWC/HDPE/GI pipe in the trench and refilling and concreting it afterwards as per original condition. In hard rocky ground area, cables will be laid normally on layer of soft earth of 0.05 Mtr. thickness previously deposited at bottom of the trench. The cutting to be filled and finished with cement/concrete, as per the RDSO drawing no. SDO/Cable laying/008, issued vide RDSO document no. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014 or latest. | — | — | — | 7,940.5 | |
| — | 100.00 | — | — | ||
| Supply of 16/0.2 mm (0.5 sq mm) PVC insulated multi strand, single core, tinned copper conductor, as per RDSO Specn.No.IRS:S-76/89 (Amnd-3) or latest. Each coil should be of 100/200/500 meters length. Colour of the wire will be specified by the Engineer incharge. (Inspection by RDSO). | — | — | — | 1,075 | |
| — | 100.00 | — | — | ||
| Supply of 1 x 16 Sqmm (Red/Black/Green) multi strand pvc insulated copper flexible power wire, and test parameters as per RDSO Specn.No.IRS:S-76/89(Amnd.3) or latest. Colour of the wire which is required will be specified by the Engineer incharge. (Inspection by RDSO) | — | — | — | 14,787 | |
| — | 100.00 | — | — | ||
| Supply of 1 x 10 Sqmm (Red/Black/Green) multi strand pvc insulated copper flexible power wire, and test parameters as per RDSO Specn.No.IRS:S-76/89(Amnd.3) or latest. Colour of the wire which is required will be specified by the Engineer incharge. (Inspection by RDSO). | — | — | — | 13,246 | |
| — | 50.00 | — | — | ||
| Supply of 1 x 25 Sqmm (Red/Black/Green) multi strand pvc insulated copper flexible power wire, and test parameters as per RDSO Specn.No.IRS:S-76/89(Amnd.3) or latest. Colour of the wire which is required will be specified by the Engineer incharge. (Inspection by RDSO). | — | — | — | 20,437.5 | |
| — | 5.00 | — | — | ||
| Fabrication, supply and fixing of 'P', 'C', 'A', 'G', 'IBS' etc. marker disk painted and lettered with enameled paint of approved colours, on signals, conforming to RDSO Drg. No.SA - 23456, as per standard practice and technical specifications. (Inspection by Consignee). | — | — | — | 2,361.9 | |
| — | 1.00 | — | — | ||
| Supply, fabrication & fixing of SWRD boards (Inspection by Consignee). | — | — | — | 4,127.64 | |
| — | 3.00 | — | — | ||
| Supply of 24 fiber optical fiber cable straight joint enclosure (SJC) complete with all accessories along with enclosures with heat shrinkable splice protection sleeve as per RDSO spec. RDSO/SPN/TC68/2014 Revision 1.0, Amndt. 1.0 or latest. Splice losses in no case should be more than 0.1 db. (Inspection by consignee). | — | — | — | 16,516.35 | |
| — | 3.00 | — | — | ||
| Splicing of 24 core optic fiber cable and making the splicing joint with contractor's own machine and tools. Joint should be prepared in such a way that the top of the enclosure should be at a depth of minimum 1.2 Mtr and the enclosure should be covered with soft soil and bricks. Splice loss of each fiber should be less than 0.05 db. | — | — | — | 36,027.03 | |
| — | 5.00 | — | — | ||
| Supply & provision of cable jointing heat shrinkable type kit from RDSO approved sources RAYCHEM/REPL or similar make for 12C/19C/24C/30C signalling cables (Inspection by Consignee). | — | — | — | 10,199.65 | |
| — | 2.00 | — | — | ||
| Fabrication and fixing of phenolic laminated sheet of grade P3, minimum 10 mm thick, as per Apparatus case diagram/plan, in location box by providing all fixtures like ARA/Disconnect terminals, fuse blocks, fuses, relays on square bars etc. including fixing of PVC coated string rods at the back side for cable support with contractor's own material like iron angle, nuts, bolts etc. The iron angle for fixing shall be minimum 3 mm thick. This also includes fixing of teak wood shelf minimum 25 mm thick for holding track circuit equipments. The work shall be done as per instructions of Rly engineer at site. (Apparatus case Half). | — | — | — | 4,856.36 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .