| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30 LAccepted-AOC | ₹30 L Quoted ₹6.4 Cr | L1 | Accepted-AOC approximate value under the scheme deposit work |
| 2 | L2₹30 L+₹1.8 L (0.28%)Accepted-AOC | ₹30 L+₹1.8 L (0.28%) Quoted ₹6.4 Cr | L2 | Accepted-AOC approximate value under the scheme deposit work |
| 3 | L3₹30 L+₹2.1 L (0.33%)Accepted-AOC 9 628 REWA NIRALA REWA VILLAGE TOWN NAGAR CITY REWA REWA MADHYA PRADESH 486002 INDIA | REWA | MADHYA PRADESH | 486002 | ₹30 L+₹2.1 L (0.33%) Quoted ₹6.4 Cr | L3 | Accepted-AOC approximate value under the scheme deposit work |
| 4 | L4₹30 L+₹18.3 L (2.88%)Accepted-AOC | ₹30 L+₹18.3 L (2.88%) Quoted ₹6.6 Cr | L4 | Accepted-AOC approximate value under the scheme deposit work |
| 5 | L5₹30 L+₹3.4 Cr (53.1%)Accepted-AOC | ₹30 L+₹3.4 Cr (53.1%) Quoted ₹9.8 Cr | L5 | Accepted-AOC approximate value under the scheme deposit work |
Tender Value
₹3 Cr
EMD Value
₹1 L
Closing Date
3 Feb 2022, 5:00 pmClosed
SECRETARY DPC AND SE O AND M MPPKVVCL REWA
SECRETARY DPC AND SE O AND M MPPKVVCL REWA
Erection/Testing and Commissioning of new 33KV/11KV/LT Lines/distribution substations etc and other miscellaneous work, on turnkey basis in rural/urban areas of Rewa District under OANDM Circle, Rewa.
2022_PKVVC_180358_1
053-10/05/DPC/6069dt19-01-22
Open Tender
Electrical Works
Item Wise
365 days
REWA
Please refer Tender documents.
5 documents required · 5 mandatory
₹5,600
₹1 L
31 Mar 2022
20 Jan 2022
7 Feb 2022
20 Jan 2022
3 Feb 2022
20 Jan 2022
Rate as percentage of current schedule of rate of MPPKVVCL, Jabalpur (excluding GST) for execution of work towards 33KV/11KV Line, DTR S/s, LT line & other miscellaneous work (as the case may be) etc, including labour and transportation of materials, on turnkey basis in rural/urban area’s of Rewa Distt.under DPC, Rewa
33 KV line on 280 Kg., 9.1 Mtrs. Long PCC poles with Raccoon conductor with average span of 70 mtr FOR RURAL AREA
33 KV line on 280 Kg., 9.1 Mtrs. Long PCC poles with Dog conductor with average span of 70 mtr-FOR RURAL AREA
33 KV line on H-Beams 152 X 152 mm., 37.1 Kg./Mtr. 13 Mtr. Long supports with Dog conductor with average span of 70 mtr-FOR RURAL AREA
33 KV line on H-Beams 152 X 152 mm., 37.1 Kg./Mtr. 13 Mtr. Long supports with Dog conductor with average span of 40 mtr-FOR URBAN AREA
33 KV line on H-Beams 152 X 152 mm., 37.1 Kg./Mtr. 13 Mtr. Long supports using Dog conductor double circuit single stringing (DCSS) FOR URBAN AREA
33 KV line on H-Beams 152 X 152 mm., 37.1 Kg./Mtr. 13 Mtr. Long supports using Dog conductor double circuit double stringing (DCDS) FOR URBAN AREA
Conversion of DCSS to DCDS in 33 KV FOR URBAN AREA
33 KV line on H-Beams 152 X 152 mm., 37.1 Kg./Mtr. 15 Mtr. Long supports using Dog conductor double circuit single stringing (DCSS) FOR URBAN AREA
33 KV line on H-Beams 152 X 152 mm., 37.1 Kg./Mtr. 15 Mtr. Long supports using Dog conductor double circuit double stringing (DCDS) FOR URBAN AREA
Conversion of DCSS to DCDS in 33 KV FOR URBAN AREA
33 KV D.P.structure on 280 Kg.,9.1 Mtrs.long PCC poles
33 KV D.P.structure on H-Beams 152 X 152 mm., 37.1 Kg./Mtr.13 Mtr. Long
33 KV D.P.structure on H-Beams 152 X 152 mm., 37.1 Kg./Mtr.13Mtr. Long for double circuit single stringing
33 KV D.P.structure on H-Beams 152 X 152 mm., 37.1 Kg./Mtr.13Mtr. Long for double stringing double circuit
33 KV Tapping D.P.structure on 280 Kg.,9.1 Mtrs.long PCC poles
33 KV Tapping D.P.structure on H-Beams 152 X 152 mm., 37.1 Kg./Mtr.13 Mtr. Long
Mid Span Pole/ Replacement of Deteriorated/ damaged poles in 33 KV lines- PCC Pole 280 Kg 9.1 m
33 KV line on H-Beams 152 X 152 mm., 37.1 Kg./Mtr. 13 Mtr. Long supports with AB Cable with average span of 30 mtr
33 kV line for under ground railway crossing by one+one cable
33 kV line for under ground National Highway by one+one cable
Augmentation of 1 Km of 33 kV Line on H-Beam with Dog conductor from Raccoon
Road Crossing for 33KV (Overhead) excluding National Highway (NH) OR State Highway (SH)
14Mtr MonoPole Suspension Type Monopole (0-2 Deg) with average Span of 100M
14Mtr MonoPole Suspension Type Monopole (2-30 Deg) with average Span of 100M
14Mtr MonoPole Suspension Type Monopole (2-30 Deg) with average Span of 100M Sectionoliser location With Isolator installation
14Mtr MonoPole Suspension Type Monopole (30-60 Deg) with average Span of 100M
14Mtr MonoPole Suspension Type Monopole (30-60 Deg) with average Span of 100M-Special terminal location for HT AB cable junction
14Mtr MonoPole Suspension Type Monopole (60-90 Deg) with average Span of 100M
17 Mtr MonoPole Suspension Type Monopole (0-2 Deg) with average Span of 100M
17 Mtr MonoPole Suspension Type Monopole (2-30 Deg) with average Span of 100M
17 Mtr MonoPole Suspension Type Monopole (30-60 Deg) with average Span of 100M
1 KM OF 11 KV LINE ON H-Beam Using Raccoon Conductor Max Span 50 Mtrs IN RURAL AREA
1 KM OF 11 KV LINE ON PCC Pole Using Rabbit Conductor Max Span 70 Mtrs IN RURAL AREA
1 KM OF 11 KV LINE ON RSJ Using Rabbit Conductor Max Span 70 Mtrs IN RURAL AREA
1 KM OF 11 KV LINE ON H-BEAM with Dog Conductor Average Span 40 Mtrs for Urban Area(DCSS)
1 KM OF 11 KV LINE ON H-BEAM with Dog Conductor Average Span 40 Mtrs for Urban Area(DCDS).
Conversion of DCSS to DCDS in 11 KV
1 Km of 11 KV Line on 152X152mm,37.1 Kg/Mtr. 13 Mtr. Long H-Beam with 35 sq.mm. AB Cable Avarage span 30 Mtrs.
1 Km of 11 KV Line on 152X152mm,37.1 Kg/Mtr. 13 Mtr. Long H-Beam with 70 sq.mm. AB Cable Avarage span 30 Mtrs.
1 Km of 11 KV Line on 152X152mm,37.1 Kg/Mtr. 13 Mtr. Long H-Beam with 95 sq.mm. AB Cable Avarage span 30 Mtrs.
11 kV Line under ground Railway crossing with Cable one+ one (3x300 sq.mm.)
Augmentaion of existing 11 KV line on Weasel to Rabbit
Augmentaion of existing 11 KV line on Weasel to Raccoon
11 KV D.P.structures on 140 Kg.,8.0 Mtrs.long PCC poles for straight line
11 KV D.P.structures on 140 Kg.,8.0 Mtrs.long PCC poles for tapping DP
11 KV D.P.Structure on H-Beams 152 X 152 mm., 37.1 Kg./mtr 13 Mtr. Long (Single Circuit)
11 KV D.P.Structure on H-Beams 152 X 152 mm., 37.1 Kg./mtr 11 Mtr. Long (Single Circuit)
11 KV D.P.Structure on H-Beams 152 X 152 mm., 37.1 Kg./mtr 13 Mtr. Long for DCDS
11 KV D.P.Structure on R S Joist 175x85mm 19.6 Kg./mtr 9.3 mtr long, (Take off DP)
11 KV Tapping D.P.Structure on on H-Beams 152 X 152 mm., 37.1 Kg./mtr 13 Mtr. Long
MID SPAN POLE/ REPLACEMENT OF DETORIATED/ DAMAGED POLES IN 11 KV LINES PCC Pole 140 Kg
Road Crossing for 11KV (Overhead) excluding National Highway (NH) OR State Highway (SH)
Road Crossing for 11KV (Overhead) excluding National Highway (NH) OR State Highway (SH)
25 KVA on 140 Kg., 8.0 Mtrs.long PCC poles
63 KVA on 140 Kg., 8.0 Mtrs.long PCC poles
100 KVA on 140 Kg., 8.0 Mtrs.long PCC poles
63 KVA on 175x85mm,11.0 Mtrs.long RS joist
100 KVA on 175x85mm,11.0 Mtrs.long RS joist
200 KVA on 175x85mm,11.0 Mtrs.long RS joist
315 KVA on 175x85mm,11.0 Mtrs.long RS joist
63 KVA on 152x152x37.1 kg/mtr ,11.0 Mtrs.long H-Beam
100 KVA on 152x152x37.1 kg/mtr ,11.0 Mtrs.long H-Beam
200 KVA on 152x152x37.1 kg/mtr ,11.0 Mtrs.long H-Beam
315 KVA on 152x152x37.1 kg/mtr ,11.0 Mtrs.long H-Beam
(i) 3 X 25 + 1 X 16 + 1 X 35 sq.mm. insulated nuetral massenger(Span of 50 Mtr)
(ii) 3 X35 + 1 X 16 + 1 X 35 sq.mm. insulated nuetral massenger(Span of 50 Mtr)
(iii) 3 X 50 + 1 X 16 + 1 X 35 sq.mm. insulated nuetral massenger (Span of 50 Mtr)
(iv) 3X70 + 1X16 + 1X35 Sq mm. (insulated nuetral massenger)(Span of 40 Mtr)
(v) 3X95 + 1X16 + 1X50 Sq mm. (insulated nuetral massenger)(Span of 40 Mtr)
(vi) 3X120 + 1X16 + 1X70 Sq mm. (insulated nuetral massenger)(Span of 35 Mtr)
(vii) 3X150 + 1X35 + 1X95 Sq mm. (insulated nuetral massenger)(Span of 35 Mtr)
(i) 3 X 16 + 1 X 16 + 1 X 25 sq.mm. (insulated nuetral massenger)
(ii) 3 X 25 + 1 X 16 + 1 X 35 sq.mm. (insulated nuetral massenger)
(iii) 3 X35 + 1 X 16 + 1 X 35 sq.mm.(insulated nuetral massenger)
(iv) 3 X 50 + 1 X 16 + 1 X 35 sq.mm.(insulated nuetral massenger)
(i) 2 X 25 + 1 X 16 sq.mm. (insulated nuetral massenger)
(ii) 2 X 35 + 1 X 16 sq.mm. (insulated nuetral massenger)
(i) 3 X 50 + 1 X 16 + 1 X 35 sq.mm.(insulated nuetral massenger)
(ii) 3 X 25 + 1 X 16 + 1 X 35 sq.mm. (insulated nuetral massenger)
(iii) 3X70 + 1X16 + 1X35 Sq mm. (insulated nuetral massenger)
(iv) 3X95 + 1X16 + 1X50 Sq mm. (insulated nuetral massenger)
(v)3X120 + 1X16 + 1X70 Sq mm. (insulated nuetral massenger)
(vi) 3X150 + 1X35 + 1X95 Sq mm. (insulated nuetral massenger)
LT line three phase 4 wire on PCC support using Rabbit and Weasel conductor with max. span 50 mtrs.
RAMESH KUMAR TIWARI
REMARK ELECTROCON PRIVATE LIMITED
RAMESH PRATAP SINGH
SHUKLA ENTERPRISES
PIYUSH DWIDEDI
PRAMEER AND COMPANY
Bidder Name
ABHINAV DWIVEDI
ABHINAV DWIVEDI
REMARK ELECTROCON PRIVATE LIMITED
RAMESH KUMAR TIWARI
PRAMEER AND COMPANY
PIYUSH DWIDEDI
RAMESH PRATAP SINGH
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .